Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Acta Radiol ; 65(7): 724-734, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38630492

RESUMEN

BACKGROUND: Dynamic myocardial computed tomography perfusion (CTP) is a novel imaging technique that increases the applicability of CT for cardiac imaging; however, the scanning requires a substantial radiation dose. PURPOSE: To investigate the feasibility of dose reduction in dynamic CTP by comparing all-heartbeat acquisitions to periodic skipping of heartbeats. MATERIAL AND METHODS: We retrieved imaging data of 38 dynamic CTP patients and created new datasets with every fourth, third or second beat (Skip1:4, Skip1:3, Skip1:2, respectively) removed. Seven observers evaluated the resulting images and perfusion maps for perfusion deficits. The mean blood flow (MBF) in each of the 16 myocardial segments was compared per skipped-beat level, normalized by the respective MBF for the full dose, and averaged across patients. The number of segments/cases whose MBF was <1.0 mL/g/min were counted. RESULTS: Out of 608 segments in 38 cases, the total additional number of false-negative (FN) segments over those present in the full-dose acquisitions and the number of additional false-positive cases were shown as acquisition (segment [%], case): Skip1:4: 7 (1.2%, 1); Skip1:3: 12 (2%, 3), and Skip1:2: 5 (0.8%, 2). The variability in quantitative MBF analysis in the repeated analysis for the reference condition resulted in 8 (1.3%) additional FN segments. The normalized results show a comparable MBF across all segments and patients, with relative mean MBFs as 1.02 ± 0.16, 1.03 ± 0.25, and 1.06 ± 0.30 for the Skip1:4, Skip1:3, and Skip1:2 protocols, respectively. CONCLUSION: Skipping every second beat acquisition during dynamic myocardial CTP appears feasible and may result in a radiation dose reduction of 50%. Diagnostic performance does not decrease after removing 50% of time points in dynamic sequence.


Asunto(s)
Imagen de Perfusión Miocárdica , Dosis de Radiación , Humanos , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Imagen de Perfusión Miocárdica/métodos , Anciano , Estudios de Factibilidad , Tomografía Computarizada por Rayos X/métodos , Adulto , Frecuencia Cardíaca/fisiología , Anciano de 80 o más Años
2.
BMC Med Educ ; 24(1): 891, 2024 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-39160535

RESUMEN

BACKGROUND: Imaging techniques play a central role in modern medicine and therefore it would be beneficial for all medical students to incorporate radiology education in medical school curricula. However, a formal undergraduate radiology curriculum with well-defined learning objectives remains lacking in The Netherlands. This study aims to qualitatively ascertain opinions from clinicians (radiologists and non-radiologists) with regard to radiology education in the medical school curricula, including topics, teaching methods and strategies. METHODS: A qualitative study with in-depth semi-structured interviews was conducted. Inclusion was carried out until saturation was achieved, after which 2 additional interviews were held. Interviews were conducted using open-ended questions, following a predefined topic list. The constant comparative method was applied in order to include new questions when unexpected topics arose during the interviews. All interviews were transcribed verbatim and coded using a thematic analysis approach. Codes were organized into categories and themes by discussion between the researchers. RESULTS: Forty-four clinicians were interviewed (8 radiologists, 36 non-radiologists). The three main themes that were derived from the interviews were: (1) expectations of indispensable knowledge and skills on radiology, (2) organization of radiology education within the medical curriculum and (3) promising educational innovations for the radiology curriculum. The qualitative study design provides more in-depth knowledge on clinicians' views on educational topics. CONCLUSIONS: The themes and statements of this study provided new insights into educational methods, timing of radiology education and new topics to teach. More research is needed to gain consensus on these subjects and inclusion of the opinion of medical students with regard to radiology education is needed.


Asunto(s)
Curriculum , Educación de Pregrado en Medicina , Investigación Cualitativa , Radiología , Estudiantes de Medicina , Humanos , Radiología/educación , Países Bajos , Educación de Pregrado en Medicina/métodos , Enseñanza , Masculino , Femenino , Entrevistas como Asunto , Adulto , Actitud del Personal de Salud
3.
BMC Med Educ ; 24(1): 479, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38693517

RESUMEN

BACKGROUND: Modern medicine becomes more dependent on radiologic imaging techniques. Over the past decade, radiology has also gained more attention in the medical curricula. However, little is known with regard to students' perspectives on this subject. Therefore, this study aims to gain insight into the thoughts and ideas of medical students and junior doctors on radiology education in medical curricula. METHODS: A qualitative, descriptive study was carried out at one medical university in the Netherlands. Participants were recruited on social media and were interviewed following a predefined topic list. The constant comparative method was applied in order to include new questions when unexpected topics arose during the interviews. All interviews were transcribed verbatim and coded. Codes were organized into categories and themes by discussion between researchers. RESULTS: Fifteen participants (nine junior doctors and six students) agreed to join. From the coded interviews, four themes derived from fifteen categories arose: (1) The added value of radiology education in medical curricula, (2) Indispensable knowledge on radiology, (3) Organization of radiology education and (4) Promising educational innovations for the radiology curriculum. CONCLUSION: This study suggests that medical students and junior doctors value radiology education. It provides insights in educational topics and forms for educational improvement for radiology educators.


Asunto(s)
Curriculum , Investigación Cualitativa , Radiología , Estudiantes de Medicina , Humanos , Países Bajos , Radiología/educación , Estudiantes de Medicina/psicología , Masculino , Femenino , Cuerpo Médico de Hospitales/educación , Actitud del Personal de Salud , Educación de Pregrado en Medicina , Entrevistas como Asunto , Adulto , Facultades de Medicina
4.
Acta Radiol ; 64(3): 999-1006, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35765201

RESUMEN

BACKGROUND: Dynamic myocardial computed tomography perfusion (CTP) is a novel technique able to depict cardiac ischemia. PURPOSE: To evaluate the impact of a four-dimensional noise reduction filter (similarity filter [4D-SF]) on image quality in dynamic CTP imaging, allowing for substantial radiation dose reduction. MATERIAL AND METHODS: Dynamic CTP datasets of 30 patients (16 women) with suspected coronary artery disease, acquired with a 320-slice CT system, were retrieved, reconstructed with the deep learning-based algorithm of the system (DLR), and filtered with the 4D-SF. For each case, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in six regions of interest (33-38mm2) were calculated before and after filtering, in four-chamber and short-axis views, and t-tested. Furthermore, six radiologists of different expertise evaluated subjective image preference by answering five visual grading analysis-type questions (regarding acceptable level of noise, absence of artifacts, natural appearance, cardiac contour sharpness, diagnostic acceptability) using a 5-point scale. The results were analyzed using visual grade characteristics (VGC) and intraclass correlation coefficient (ICC). RESULTS: Mean SNR in four-chamber view (unfiltered vs. filtered) were: septum=4.1 ± 2.1 versus 7.6 ± 5.6; lateral wall=4.5 ± 2.0 versus 8.0 ± 4.9; CNRseptum=16.6 ± 8.9 versus 31.7 ± 28; lateral wall=16.2 ± 8.9 versus 31.3 ± 28.9. Similar results were obtained in short-axis view. The perceived filtered image quality indicated decreased noise (VGCAUC=0.96) and artifacts (0.65), improved natural appearance (0.59), cardiac contour sharpness (0.74), and diagnostic acceptability (0.78). The inter-observer variability was excellent (ICC=0.79). All results were statistically significant (P < 0.05). CONCLUSION: Similarity filtering after DLR improves image quality, possibly enabling dose reduction in dynamic CTP imaging in patient with suspected chronic coronary syndrome.


Asunto(s)
Enfermedad de la Arteria Coronaria , Imagen de Perfusión Miocárdica , Humanos , Femenino , Imagen de Perfusión Miocárdica/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Miocardio , Corazón/diagnóstico por imagen , Relación Señal-Ruido , Algoritmos , Tomografía , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Dosis de Radiación
5.
Clin Infect Dis ; 73(5): e1089-e1098, 2021 09 07.
Artículo en Inglés | MEDLINE | ID: mdl-33220049

RESUMEN

BACKGROUND: Long-term health sequelae of coronavirus disease 2019 (COVID-19) may be multiple but have thus far not been systematically studied. METHODS: All patients discharged after COVID-19 from the Radboud University Medical Center, Nijmegen, the Netherlands, were consecutively invited to a multidisciplinary outpatient facility. Also, nonadmitted patients with mild disease but with symptoms persisting >6 weeks could be referred by general practitioners. Patients underwent a standardized assessment including measurements of lung function, chest computed tomography (CT)/X-ray, 6-minute walking test, body composition, and questionnaires on mental, cognitive, health status, and quality of life (QoL). RESULTS: 124 patients (59 ±â€…14 years, 60% male) were included: 27 with mild, 51 with moderate, 26 with severe, and 20 with critical disease. Lung diffusion capacity was below the lower limit of normal in 42% of discharged patients. 99% of discharged patients had reduced ground-glass opacification on repeat CT imaging, and normal chest X-rays were found in 93% of patients with mild disease. Residual pulmonary parenchymal abnormalities were present in 91% of discharged patients and correlated with reduced lung diffusion capacity. Twenty-two percent had low exercise capacity, 19% low fat-free mass index, and problems in mental and/or cognitive function were found in 36% of patients. Health status was generally poor, particularly in the domains functional impairment (64%), fatigue (69%), and QoL (72%). CONCLUSIONS: This comprehensive health assessment revealed severe problems in several health domains in a substantial number of ex-COVID-19 patients. Longer follow-up studies are warranted to elucidate natural trajectories and to find predictors of complicated long-term trajectories of recovery.


Asunto(s)
COVID-19 , Enfermedades Pulmonares , Anciano , Femenino , Humanos , Pulmón , Masculino , Persona de Mediana Edad , Calidad de Vida , SARS-CoV-2
6.
Radiology ; 298(1): E18-E28, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32729810

RESUMEN

Background The coronavirus disease 2019 (COVID-19) pandemic has spread across the globe with alarming speed, morbidity, and mortality. Immediate triage of patients with chest infections suspected to be caused by COVID-19 using chest CT may be of assistance when results from definitive viral testing are delayed. Purpose To develop and validate an artificial intelligence (AI) system to score the likelihood and extent of pulmonary COVID-19 on chest CT scans using the COVID-19 Reporting and Data System (CO-RADS) and CT severity scoring systems. Materials and Methods The CO-RADS AI system consists of three deep-learning algorithms that automatically segment the five pulmonary lobes, assign a CO-RADS score for the suspicion of COVID-19, and assign a CT severity score for the degree of parenchymal involvement per lobe. This study retrospectively included patients who underwent a nonenhanced chest CT examination because of clinical suspicion of COVID-19 at two medical centers. The system was trained, validated, and tested with data from one of the centers. Data from the second center served as an external test set. Diagnostic performance and agreement with scores assigned by eight independent observers were measured using receiver operating characteristic analysis, linearly weighted κ values, and classification accuracy. Results A total of 105 patients (mean age, 62 years ± 16 [standard deviation]; 61 men) and 262 patients (mean age, 64 years ± 16; 154 men) were evaluated in the internal and external test sets, respectively. The system discriminated between patients with COVID-19 and those without COVID-19, with areas under the receiver operating characteristic curve of 0.95 (95% CI: 0.91, 0.98) and 0.88 (95% CI: 0.84, 0.93), for the internal and external test sets, respectively. Agreement with the eight human observers was moderate to substantial, with mean linearly weighted κ values of 0.60 ± 0.01 for CO-RADS scores and 0.54 ± 0.01 for CT severity scores. Conclusion With high diagnostic performance, the CO-RADS AI system correctly identified patients with COVID-19 using chest CT scans and assigned standardized CO-RADS and CT severity scores that demonstrated good agreement with findings from eight independent observers and generalized well to external data. © RSNA, 2020 Supplemental material is available for this article.


Asunto(s)
Inteligencia Artificial , COVID-19/diagnóstico por imagen , Índice de Severidad de la Enfermedad , Tórax/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Anciano , Sistemas de Datos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos de Investigación , Estudios Retrospectivos
7.
Radiology ; 296(2): E97-E104, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32339082

RESUMEN

Background A categorical CT assessment scheme for suspicion of pulmonary involvement of coronavirus disease 2019 (COVID-19 provides a basis for gathering scientific evidence and improved communication with referring physicians. Purpose To introduce the COVID-19 Reporting and Data System (CO-RADS) for use in the standardized assessment of pulmonary involvement of COVID-19 on unenhanced chest CT images and to report its initial interobserver agreement and performance. Materials and Methods The Dutch Radiological Society developed CO-RADS based on other efforts for standardization, such as the Lung Imaging Reporting and Data System or Breast Imaging Reporting and Data System. CO-RADS assesses the suspicion for pulmonary involvement of COVID-19 on a scale from 1 (very low) to 5 (very high). The system is meant to be used in patients with moderate to severe symptoms of COVID-19. The system was evaluated by using 105 chest CT scans of patients admitted to the hospital with clinical suspicion of COVID-19 and in whom reverse transcription-polymerase chain reaction (RT-PCR) was performed (mean, 62 years ± 16 [standard deviation]; 61 men, 53 with positive RT-PCR results). Eight observers used CO-RADS to assess the scans. Fleiss κ value was calculated, and scores of individual observers were compared with the median of the remaining seven observers. The resulting area under the receiver operating characteristics curve (AUC) was compared with results from RT-PCR and clinical diagnosis of COVID-19. Results There was absolute agreement among observers in 573 (68.2%) of 840 observations. Fleiss κ value was 0.47 (95% confidence interval [CI]: 0.45, 0.47), with the highest κ value for CO-RADS categories 1 (0.58, 95% CI: 0.54, 0.62) and 5 (0.68, 95% CI: 0.65, 0.72). The average AUC was 0.91 (95% CI: 0.85, 0.97) for predicting RT-PCR outcome and 0.95 (95% CI: 0.91, 0.99) for clinical diagnosis. The false-negative rate for CO-RADS 1 was nine of 161 cases (5.6%; 95% CI: 1.0%, 10%), and the false-positive rate for CO-RADS category 5 was one of 286 (0.3%; 95% CI: 0%, 1.0%). Conclusion The coronavirus disease 2019 (COVID-19) Reporting and Data System (CO-RADS) is a categorical assessment scheme for pulmonary involvement of COVID-19 at unenhanced chest CT that performs very well in predicting COVID-19 in patients with moderate to severe symptoms and has substantial interobserver agreement, especially for categories 1 and 5. © RSNA, 2020 Online supplemental material is available for this article.


Asunto(s)
Betacoronavirus , Infecciones por Coronavirus/diagnóstico por imagen , Neumonía Viral/diagnóstico por imagen , Tomografía Computarizada por Rayos X/normas , Adulto , Anciano , COVID-19 , Comunicación , Femenino , Humanos , Pulmón/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Países Bajos , Variaciones Dependientes del Observador , Pandemias , Sistemas de Información Radiológica , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , SARS-CoV-2 , Tomografía Computarizada por Rayos X/métodos
8.
Eur Radiol ; 30(5): 2552-2560, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32040726

RESUMEN

OBJECTIVES: To evaluate the technical performance of an ultra-high-resolution CT (UHRCT) system. METHODS: The physico-technical capabilities of a novel commercial UHRCT system were assessed and compared with those of a current-generation multi-detector (MDCT) system. The super-high-resolution (SHR) mode of the system uses 0.25 mm (at isocentre) detector elements (dels) in the in-plane and longitudinal directions, while the high-resolution (HR) mode bins two dels in the longitudinal direction. The normal-resolution (NR) mode bins dels 2 × 2, resulting in a del-size equivalent to that of the MDCT system. In general, standard procedures and phantoms were used to perform these assessments. RESULTS: The UHRCT MTF (10% MTF 4.1 lp/mm) is twice as high as that of the MDCT (10% MTF 1.9 lp/mm), which is comparable to the MTF in the NR mode (10% MTF 1.7 lp/mm). The width of the slice sensitivity profile in the SHR mode (FWHM 0.45 mm) is about 60% of that of the MDCT (FWHM 0.77 mm). Uniformity and CT numbers are within the expected range. Noise in the high-resolution modes has a higher magnitude and higher frequency components compared with MDCT. Low-contrast visibility is lower for the NR, HR and SHR modes compared with MDCT, but about a 14%, for NR, and 23%, for HR and SHR, dose increase gives the same results. CONCLUSIONS: HR and SHR mode scanning results in double the spatial resolution, with about a 23% increase in dose required to achieve the same low-contrast detectability. KEY POINTS: • Resolution on UHRCT is up to twice as high as for the tested MDCT. • With abdominal settings, UHRCT needs higher dose for the same low-contrast detectability as MDCT, but dose is still below achievable levels as defined by current diagnostic reference levels. • The UHRCT system used in normal-resolution mode yields comparable resolution and noise characteristics as the MDCT system.


Asunto(s)
Tomógrafos Computarizados por Rayos X , Tomografía Computarizada por Rayos X/métodos , Diseño de Equipo , Humanos , Fantasmas de Imagen , Reproducibilidad de los Resultados
9.
Eur Radiol ; 30(8): 4709-4710, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32215693

RESUMEN

The original version of this article, published on 10 February 2019, unfortunately contained a mistake. The axes of the graphs in Fig. 3 are incorrect. The correct figure is given below. Therefore, the last two sentences in "Results," section "Noise," should read: "The peak frequency of the HR and SHR was 0.21 lp/mm. For the NR mode and the MDCT, the peak frequencies were 0.17 lp/mm and 0.21 lp/mm, respectively."

10.
Radiology ; 292(1): 197-205, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31084482

RESUMEN

Background Dual-energy CT iodine maps are used to detect pulmonary embolism (PE) with CT angiography but require dedicated hardware. Subtraction CT, a software-only solution, results in iodine maps with high contrast-to-noise ratios. Purpose To compare the use of subtraction CT versus dual-energy CT iodine maps to CT angiography for PE detection. Materials and Methods In this prospective study ( https://clinicaltrials.gov , NCT02890706), 274 participants suspected of having PE underwent precontrast CT followed by contrast material-enhanced dual-energy CT angiography between July 2016 and April 2017. Iodine maps from dual-energy CT were derived. Subtraction maps (contrast-enhanced CT minus precontrast CT) were calculated after motion correction. Truth was established by expert consensus. A total of 75 randomly selected participants with and without PE (1:1 ratio) were evaluated by three radiologists and six radiology residents (blinded to final diagnosis) for the presence of PE using three types of CT: CT angiography alone, dual-energy CT, and subtraction CT. The partial area under the receiver operating characteristic curve (AUC) for the clinically relevant specificity region (maximum partial AUC, 0.11) was compared by using multireader multicase variance. A P value less than or equal to .025 was considered indicative of a significant difference due to multiple comparisons. Results There were 35 men and 40 women in the reader study (mean age, 63 years ± 12 [standard deviation]). The pooled sensitivities were not different (P ≥ .31 among techniques) (95% confidence intervals [CIs]: 67%, 89% for CT angiography; 72%, 91% for dual-energy CT; 70%, 91% for subtraction CT). However, pooled specificity was higher for subtraction CT (95% CI: 100%, 100%) than for CT angiography (95% CI: 89%, 97%) or dual-energy CT (95% CI: 89%, 98%) (P < .001). Partial AUCs for the average observer improved equally when adding iodine maps (subtraction CT [0.093] vs CT angiography [0.088], P = .03; dual-energy CT [0.094] vs CT angiography, P = .01; dual-energy CT vs subtraction CT, P = .68). Average reading times were equivalent (range, 97-101 seconds; P ≥ .41) among techniques. Conclusion Subtraction CT iodine maps had greater specificity than CT angiography alone in pulmonary embolism detection. Subtraction CT had comparable diagnostic performance to that of dual-energy CT, without the need for dedicated hardware. © RSNA, 2019 Online supplemental material is available for this article.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Medios de Contraste , Yodo , Embolia Pulmonar/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
11.
Eur Radiol ; 29(3): 1408-1414, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30255247

RESUMEN

Subtraction computed tomography (SCT) is a technique that uses software-based motion correction between an unenhanced and an enhanced CT scan for obtaining the iodine distribution in the pulmonary parenchyma. This technique has been implemented in clinical practice for the evaluation of lung perfusion in CT pulmonary angiography (CTPA) in patients with suspicion of acute and chronic pulmonary embolism, with acceptable radiation dose. This paper discusses the technical principles, clinical interpretation, benefits and limitations of arterial subtraction CTPA. KEY POINTS: • SCT uses motion correction and image subtraction between an unenhanced and an enhanced CT scan to obtain iodine distribution in the pulmonary parenchyma. • SCT could have an added value in detection of pulmonary embolism. • SCT requires only software implementation, making it potentially more widely available for patient care than dual-energy CT.


Asunto(s)
Angiografía de Substracción Digital/métodos , Angiografía por Tomografía Computarizada/métodos , Pulmón/diagnóstico por imagen , Embolia Pulmonar/diagnóstico , Humanos , Arteria Pulmonar/diagnóstico por imagen
12.
AJR Am J Roentgenol ; 212(6): 1253-1259, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30860897

RESUMEN

OBJECTIVE. The objective of this study was to compare the image quality of iodine maps derived from subtraction CT and from dual-energy CT (DECT) in patients with suspected pulmonary embolism (PE). SUBJECTS AND METHODS. In this prospective study conducted between July 2016 and April 2017, consecutive patients with suspected PE underwent unenhanced CT at 100 kV and dual-energy pulmonary CT angiography at 100 and 140 kV on a dual-source scanner. The scanner was set to generate subtraction and DECT iodine maps at similar radiation doses. In 55 patients (30 women, 25 men; mean age ± SD, 63.4 ± 11.9 years old), various subjective image quality criteria including diagnostic acceptability were rated on a 5-point scale by four radiologists and a radiology resident. In 29 patients (17 women, 12 men; mean age, 62.4 ± 11.7 years old) with confirmed perfusion defects, the signal-difference-to-noise ratio (SDNR) between perfusion defects and adjacent normally perfused parenchyma was measured in corresponding ROIs on subtraction and DECT iodine maps. McNemar and Wilcoxon signed-rank tests were used for statistical comparisons. RESULTS. Diagnostic acceptability was rated excellent or good in a mean of 67% (range, 31-80%) of subtraction CT studies and 36% (5-69%) of DECT studies (p < 0.05 for four of the five radiologists), mainly because of fewer artifacts on subtraction CT. Mean SDNR was marginally higher for subtraction CT than for DECT (18.6 vs 17.1, p = 0.06) and was significantly higher in the upper lobes (21.8 vs 17.9, p < 0.05). CONCLUSION. Radiologist-judged image quality of pulmonary iodine maps was higher for subtraction CT than for DECT with similar to higher SDNR. Subtraction CT is a software-only solution, so it may be an attractive alternative to DECT for depicting perfusion defects.

13.
Skeletal Radiol ; 48(6): 949-957, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30406835

RESUMEN

OBJECTIVE: To evaluate accuracy of fracture detection and therapeutic impact of a single-shot CT protocol as a primary imaging tool in all patients with clinical suspicion of wrist injury, and evaluate the resulting impact on therapy. MATERIALS AND METHODS: We performed a single-institution study on all patients with suspicion of fractures of the wrist and carpus. All patients underwent conventional radiography, thereafter single-shot wrist CT, and then 1-year follow-up. Physicians and radiologists prospectively scored likelihood of fracture presence on a five-point scale before and after CT. Three surgeons proposed a treatment regimen (functional, cast, reduction, or operative) based on clinical and radiological data, first with knowledge of conventional radiography, and then with knowledge of CT. The reference standard for fracture presence was based on all data. We performed receiver operating characteristic (ROC) analyses and calculated proportion of wrists with treatment changes due to CT imaging. RESULTS: Ninety-eight patients participated (63% female, mean age 53, range, 18-87 years old) with 100 wrist CTs. Conventional radiography detected true-positive fractures in 45, and CT in 61 wrists. The areas under the curve for fracture detection were 0.85 (95% CI 0.77-0.93) for conventional radiography and 0.97 (95% CI 0.93-1.00) for CT. Treatment changed in 24 (24%, 95% CI 16-33%) - 31 (31%, 95% CI 23-41%) wrists, mostly involving a decrease in the rate of cast immobilization. CONCLUSIONS: Single-shot CT in patients with clinical suspicion of wrist injury increases accuracy of fracture detection. This has a significant impact therapy in this population, mainly on cast immobilization. TRIAL REGISTRATION: We registered the study at www.clinicaltrials.gov , NL43482.091.13.


Asunto(s)
Fracturas Óseas/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Traumatismos de la Muñeca/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Diagnóstico Diferencial , Femenino , Fracturas Óseas/terapia , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Traumatismos de la Muñeca/terapia
14.
Eur Radiol ; 28(12): 5051-5059, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29808430

RESUMEN

OBJECTIVES: To compare contrast-to-noise ratios (CNRs) and iodine discrimination thresholds on iodine maps derived from dual energy CT (DECT) and subtraction CT (SCT). METHODS: A contrast-detail phantom experiment was performed with 2 to 15 mm diameter tubes containing water or iodinated contrast concentrations ranging from 0.5 mg/mL to 20 mg/mL. DECT scans were acquired at 100 kVp and at 140 kVp+Sn filtration. SCT scans were acquired at 100 kVp. Iodine maps were created by material decomposition (DECT) or by subtraction of water scans from iodine scans (SCT). Matched exposure levels varied from 8 to 15 mGy. Iodine discrimination thresholds (Cr) and response times were determined by eight observers. RESULTS: The adjusted mean CNR was 1.9 times higher for SCT than for DECT. Exposure level had no effect on CNR. All observers discriminated all details ≥10 mm at 12 and 15 mGy. For sub-centimetre details, the lowest calculated Cr was ≤ 0.50 mg/mL for SCT and 0.64 mg/mL for DECT. The smallest detail was discriminated at ≥4.4 mg/mL with SCT and at ≥7.4 mg/mL with DECT. Response times were lower for SCT than DECT. CONCLUSIONS: SCT results in higher CNR and reduced iodine discrimination thresholds compared to DECT for sub-centimetre details. KEY POINTS: • Subtraction CT iodine maps exhibit higher CNR than dual-energy iodine maps • Lower iodine concentrations can be discriminated for sub-cm details with SCT • Response times are lower using SCT compared to dual-energy CT.


Asunto(s)
Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Medios de Contraste , Humanos , Yodo , Fantasmas de Imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Relación Señal-Ruido
16.
Eur Heart J Cardiovasc Imaging ; 25(7): 929-936, 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38306632

RESUMEN

AIMS: To compare the novel 2D multi-velocity encoding (venc) and 4D flow acquisitions with the standard 2D flow acquisition for the assessment of paravalvular regurgitation (PVR) after transcatheter aortic valve replacement (TAVR) using cardiac magnetic resonance (CMR)-derived regurgitant fraction (RF). METHODS AND RESULTS: In this prospective study, patients underwent CMR 1 month after TAVR for the assessment of PVR, for which 2D multi-venc and 4D flow were used, in addition to standard 2D flow. Scatterplots and Bland-Altman plots were used to assess correlation and visualize agreement between techniques. Reproducibility of measurements was assessed with intraclass correlation coefficients. The study included 21 patients (mean age ± SD 80 ± 5 years, 9 men). The mean RF was 11.7 ± 10.0% when standard 2D flow was used, 10.6 ± 7.0% when 2D multi-venc flow was used, and 9.6 ± 7.3% when 4D flow was used. There was a very strong correlation between the RFs assessed with 2D multi-venc and standard 2D flow (r = 0.88, P < 0.001), and a strong correlation between the RFs assessed with 4D flow and standard 2D flow (r = 0.74, P < 0.001). Bland-Altman plots revealed no substantial bias between the RFs (2D multi-venc: 1.3%; 4D flow: 0.3%). Intra-observer and inter-observer reproducibility for 2D multi-venc flow were 0.98 and 0.97, respectively, and 0.92 and 0.90 for 4D flow, respectively. CONCLUSION: Two-dimensional multi-venc and 4D flow produce an accurate quantification of PVR after TAVR. The fast acquisition of the 2D multi-venc sequence and the free-breathing acquisition with retrospective plane selection of the 4D flow sequence provide useful advantages in clinical practice, especially in the frail TAVR population.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Imagen por Resonancia Cinemagnética , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Femenino , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/fisiopatología , Estudios Prospectivos , Anciano de 80 o más Años , Anciano , Imagen por Resonancia Cinemagnética/métodos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Reproducibilidad de los Resultados , Velocidad del Flujo Sanguíneo , Complicaciones Posoperatorias/diagnóstico por imagen , Índice de Severidad de la Enfermedad , Estudios de Cohortes
17.
BMJ Open Sport Exerc Med ; 10(2): e002070, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38882206

RESUMEN

Exercise can produce transient elevations of cardiac troponin (cTn) concentrations, which may resemble the cTn release profile of myocardial infarction. Consequently, clinical interpretation of postexercise cTn elevations (ie, values above the 99th percentile upper reference limit) remains challenging and may cause clinical confusion. Therefore, insight into the physiological versus pathological nature of postexercise cTn concentrations is warranted. We aim to (1) establish resting and postexercise reference values for recreational athletes engaged in walking, cycling or running exercise; (2) compare the prevalence of (sub)clinical coronary artery disease in athletes with high versus low postexercise cTn concentrations and (3) determine the association between postexercise cTn concentrations and the incidence of major adverse cardiovascular events (MACE) and mortality during long-term follow-up. For this purpose, the prospective TRoponin concentrations following Exercise and the Association with cardiovascular ouTcomes (TREAT) observational cohort study was designed to recruit 1500 recreational athletes aged ≥40 to <70 years who will participate in Dutch walking, cycling and running events. Baseline and postexercise high-sensitivity cTnT and cTnI concentrations will be determined. The prevalence and magnitude of coronary atherosclerosis on computed tomography (eg, coronary artery calcium score, plaque type, stenosis degree and CT-derived fractional flow reserve) will be compared between n=100 athletes with high postexercise cTn concentrations vs n=50 age-matched, sex-matched and sport type-matched athletes with low postexercise cTn concentrations. The incidence of MACE and mortality will be assessed in the entire cohort up to 20 years follow-up. The TREAT study will advance our understanding of the clinical significance of exercise-induced cTn elevations in middle-aged and older recreational athletes. Trial registration number NCT06295081.

18.
Emerg Med J ; 30(3): e23, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22593268

RESUMEN

OBJECTIVE: Currently CT is rapidly implemented in the evaluation of trauma patients. In anticipation of a large international multicentre trial, this study's aim was to evaluate the clinical feasibility of a new diagnostic protocol, used for the primary radiological evaluation in adult blunt high-energy trauma patients, especially for the use of CT. METHODS: An evidence-based flow chart was created with criteria based on trauma mechanism, physical examination and laboratory analyses to indicate appropriateness of conventional radiography (CR), sonography and CT of head, cervical spine and trunk. To evaluate this protocol, the authors prospectively included 81 consecutive patients. Collected data included protocol adherence and number and type of performed CR and CT scans. The authors also determined the time needed to perform radiological investigations, adverse events in the CT room and clinically relevant missed injuries after 1-month clinical follow-up. RESULTS: There was 99% adherence to the protocol concerning CT. Seventy-nine patients (98%) received one or more CT scans: 72 (89%) had thoracoabdominal, 78 (96%) cervical spine and 54 (67%) had cranial CT. In 30 patients, one or more CT scans of body regions could be omitted. In 38%, CR was wrongly omitted or performed incorrectly at a variance with the protocol. No major adverse events occurred in the CT room and no clinically relevant injuries were missed. CONCLUSIONS: The authors introduced a diagnostic protocol that seems feasible and safe for the evaluation of adult blunt high-energy trauma patients. Implementation of this protocol has the potential to reduce unnecessary radiological investigations, especially CT scans.


Asunto(s)
Protocolos Clínicos , Medicina Basada en la Evidencia , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Heridas no Penetrantes/diagnóstico por imagen , Adolescente , Adulto , Femenino , Escala de Coma de Glasgow , Humanos , Puntaje de Gravedad del Traumatismo , Tiempo de Internación/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estudios Prospectivos , Factores de Riesgo , Ultrasonografía , Signos Vitales
19.
Sci Rep ; 13(1): 11507, 2023 07 17.
Artículo en Inglés | MEDLINE | ID: mdl-37460572

RESUMEN

In coronavirus disease 2019 (COVID-19), endothelial cells play a central role and an inadequate response is associated with vascular complications. PET imaging with gallium-68 labelled RGD-peptide (68Ga-RGD) targets αvß3 integrin expression which allows quantification of endothelial activation. In this single-center, prospective observational study, we included ten hospitalized patients with COVID-19 between October 2020 and January 2021. Patients underwent 68Ga-RGD PET/CT followed by iodine mapping of lung parenchyma. CT-based segmentation of lung parenchyma, carotid arteries and myocardium was used to quantify tracer uptake by calculating standardized uptake values (SUV). Five non-COVID-19 patients were used as reference. The study population was 68.5 (IQR 52.0-74.5) years old, with median oxygen need of 3 l/min (IQR 0.9-4.0). 68Ga-RGD uptake quantified as SUV ± SD was increased in lungs (0.99 ± 0.32 vs. 0.45 ± 0.18, p < 0.01) and myocardium (3.44 ± 1.59 vs. 0.65 ± 0.22, p < 0.01) of COVID-19 patients compared to reference but not in the carotid arteries. Iodine maps showed local variations in parenchymal perfusion but no correlation with SUV. In conclusion, using 68Ga-RGD PET/CT in COVID-19 patients admitted with respiratory symptoms, we demonstrated increased endothelial activation in the lung parenchyma and myocardium. Our findings indicate the involvement of increased and localized endothelial cell activation in the cardiopulmonary system in COVID-19 patients.Trail registration: NCT04596943.


Asunto(s)
COVID-19 , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Persona de Mediana Edad , Anciano , Radioisótopos de Galio , Células Endoteliales/metabolismo , COVID-19/diagnóstico por imagen , Tomografía de Emisión de Positrones , Oligopéptidos , Integrina alfaVbeta3/metabolismo
20.
Eur J Radiol ; 134: 109443, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33310553

RESUMEN

OBJECTIVE: To compare nodule enhancement on subtraction CT iodine maps to that on dual-energy CT iodine maps using CT datasets acquired simultaneously. METHODS: A previously-acquired set of lung subtraction and dual-energy CT maps consisting of thirty patients with 95 solid pulmonary nodules (≥4 mm diameter) was used. Nodules were annotated and segmented on CT angiography, and mean nodule enhancement in the iodine maps calculated. Three radiologists scored nodule visibility with both techniques on a 4-point scale. RESULTS: Mean nodule enhancement was higher (p < 0.001) at subtraction CT (34.9 ±â€¯12.9 HU) than at dual-energy CT (25.4 ±â€¯21.0 HU). Nodule enhancement at subtraction CT was judged more often to be "highly visible" for each observers (p < 0.001) with an area under the curve of 0.81. CONCLUSIONS: Subtraction CT is able to depict iodine enhancement in pulmonary nodules better than dual-energy CT.


Asunto(s)
Yodo , Neoplasias Pulmonares , Nódulos Pulmonares Múltiples , Imagen Radiográfica por Emisión de Doble Fotón , Nódulo Pulmonar Solitario , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Nódulo Pulmonar Solitario/diagnóstico por imagen , Técnica de Sustracción
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA