Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
BMC Ophthalmol ; 24(1): 363, 2024 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-39179956

RESUMEN

BACKGROUND: Clinical evidence suggests an association between phosphate concentrations in aqueous humor and the risk of intraocular lens (IOL) calcification. To test this hypothesis the influence of different phosphate concentrations on IOL calcification was evaluated in an in vitro electrophoresis model. METHODS: 20 IOLs of two hydrophilic IOL models (CT Spheris 204, Zeiss; Lentis L-313, Oculentis) and one hydrophobic control IOL model (Clareon CNA0T0, Alcon) were exposed to physiologic and elevated phosphate concentrations, similar to diabetic aqueous humor. IOL calcification was analyzed by alizarin red staining, von Kossa staining, scanning electron microscopy, energy dispersive x-ray spectroscopy and transmission electron microscopy with electron diffraction. RESULTS: Higher phosphate concentrations were associated with IOL calcification. Analyses of IOL surfaces and cross-sections documented calcification in no CT Spheris and 4 Lentis IOLs following exposure to 10 mM Na2HPO4, compared with 7 and 11 positive analyses following exposure to 14 mM Na2HPO4, respectively. Furthermore, a clear association between IOL calcification and the duration of electrophoresis was demonstrated, confirming increased phosphate concentrations and duration of exposure as risk factors of IOL calcification. CONCLUSIONS: Findings suggest that higher phosphate concentrations in aqueous humor, as seen in diabetic patients, contribute to an increased IOL calcification risk, potentially explaining clinical observations showing an increased risk of IOL calcification in patients with diabetes.


Asunto(s)
Humor Acuoso , Calcinosis , Lentes Intraoculares , Fosfatos , Humanos , Humor Acuoso/metabolismo , Calcinosis/metabolismo , Fosfatos/metabolismo , Microscopía Electrónica de Rastreo , Espectrometría por Rayos X , Microscopía Electrónica de Transmisión , Factores de Riesgo
2.
Klin Monbl Augenheilkd ; 240(8): 960-970, 2023 Aug.
Artículo en Inglés, Alemán | MEDLINE | ID: mdl-37391183

RESUMEN

Opacification of intraocular lenses (IOLs) due to material changes is a serious complication that can compromise the good visual outcomes of uncomplicated cataract surgery. In hydrophobic acrylic IOLs, opacification can result from glistening formation, while in hydrophilic acrylic IOLs, there is a risk of calcification due to the formation of calcium phosphates within the polymer. Over time, various methods have been developed to investigate calcification in hydrophilic acrylic IOLs. The aim of this article is to provide an overview of standard histological staining and models used to simulate IOL calcification. Histological staining can be used to detect calcification and assess the extent of crystal formation. The development of in vivo and in vitro replication models has helped to identify the underlying pathomechanisms of calcification. In vivo models are suitable for assessing the biocompatibility of IOL materials. Bioreactors as an in vitro model can be used to investigate the kinetics of crystal formation within the polymer. The replication of IOL calcification under standardized conditions using electrophoresis allows for the comparison of different lens materials with respect to the risk of calcification. The combination of different analytical and replication methods can be used in the future to further investigate the pathomechanisms of calcium phosphate crystal formation and the influence of risk factors. This may help to prevent calcification of hydrophilic acrylic IOLs and associated explantation and complications.


Asunto(s)
Calcinosis , Extracción de Catarata , Lentes Intraoculares , Facoemulsificación , Humanos , Implantación de Lentes Intraoculares , Complicaciones Posoperatorias/etiología , Lentes Intraoculares/efectos adversos , Extracción de Catarata/efectos adversos , Calcinosis/diagnóstico , Calcinosis/etiología
3.
Ophthalmologie ; 120(10): 1022-1028, 2023 Oct.
Artículo en Alemán | MEDLINE | ID: mdl-37171476

RESUMEN

BACKGROUND: Opacification through calcification of hydrophilic acrylic intraocular lenses is a serious complication of cataract surgery, which usually results in explantation of the lens. In the process of calcification, the intraocular lens material plays a crucial role: calcification only occurs in hydrophilic acrylic lenses. Hydrophobic acrylic lenses show no crystal formation within the polymer. Hydrophilic acrylic lenses from some manufacturers have hydrophobic surface properties. The question arises as to what influence these surface properties have on the risk of calcification. OBJECTIVE: The present study investigated whether the hydrophobic surface properties of hydrophilic acrylic lenses can prevent calcification. MATERIAL AND METHODS: Using an electrophoretic in vitro model of calcification, two hydrophilic lenses with hydrophobic surface properties were compared to two hydrophilic lenses and a hydrophobic negative control to determine the risk of calcification. The lenses were then analyzed by optical microscopy, Alizarin Red and Von Kossa staining, scanning electron microscopy (SEM) and energy dispersive X­ray spectroscopy (EDX). RESULTS: All four hydrophilic lens models showed calcification within the polymer. No difference was found between the hydrophilic lenses and the hydrophilic lenses with hydrophobic surface properties in terms of crystal formation. The hydrophobic negative control showed no calcification. CONCLUSION: The investigation conducted in this study under standardized conditions could show that hydrophobic surface properties of hydrophilic acrylic lenses do not protect against calcium phosphate crystal formation within the polymer. There also is a risk of calcification in these lens models.

4.
Am J Ophthalmol ; 262: 192-198, 2023 Nov 26.
Artículo en Inglés | MEDLINE | ID: mdl-38016528

RESUMEN

PURPOSE: A complication of using silicone oil as an intraocular endotamponade is its adhesion to intraocular lenses (IOLs). Forward light scattering is a measure to quantify the optical disturbance caused by adherent oil droplets. We tested the straylight caused by silicone oil adhesion to different IOLs and examined whether an approved cleaning solution, F4H5, reverses the induced straylight. DESIGN: An experimental study. METHODS: Two hydrophobic acrylic IOL models and 1 hydrophilic model with a hydrophobic surface (n = 8 per model: 24 lenses) had straylight measured before contact with silicone oils, providing a baseline for subsequent testing: 12 lenses with lighter-than-water silicone oil (Siluron 2000) and 12 with heavier-than-water oil (Densiron 68). The final measurement was performed after cleansing with F4H5 when we used scanning electron and light microscopy to detect surface changes. RESULTS: Straylight was majorly increased in IOLs with adherent silicone oil (baseline vs adherent oil median 3.1 [2.1, 3.9] and 39.7 [22.7, 87.8] deg2/sr, respectively; P < .001). No difference was seen between heavier- and lighter-than-water silicone oils. Between IOL types, induced straylight varied significantly, with 1 hydrophobic model reaching the highest average straylight. F4H5 significantly reduced straylight values in all IOL types (median 9.4 [5.4, 13.8] deg2/sr). The microscopy revealed surface changes on the IOLs even after cleaning. CONCLUSIONS: Silicone oil adhesion to IOLs can induce amounts of straylight known to cause severe optical disturbance. F4H5 cleansing solution reversed straylight values to only slightly increased values. We found no difference in straylight formation between the lighter- and heavier-than-water silicone oils.

5.
Sci Rep ; 12(1): 7685, 2022 05 10.
Artículo en Inglés | MEDLINE | ID: mdl-35538104

RESUMEN

Opacification through calcification of hydrophilic acrylic intraocular lenses (IOL) is a severe complication after cataract surgery. Causing symptoms that range from glare through to severe vision loss, the only effective therapy is explantation of the opacified IOL so far. Although IOL calcification is a well-described phenomenon, its pathogenesis is not fully understood yet. The purpose of the current study was to develop a laboratory model to replicate IOL calcification. Calcification could be reproduced using a horizontal electrophoresis and aqueous solutions of calcium chloride and disodium hydrogen phosphate. The analysis of the in vitro calcified IOLs was performed using light microscopy, Alizarin Red and Von Kossa staining, scanning electron microscopy, energy dispersive x-ray spectroscopy and electron crystallography using transmission electron microscopy and electron diffraction. The presented laboratory model could be used to identify hydrophilic IOLs that are at risk to develop calcification and to assess the influence of associated risk factors. In addition, it can serve as a research tool to further understand this pathology.


Asunto(s)
Calcinosis , Opacificación Capsular , Lentes Intraoculares , Facoemulsificación , Calcinosis/patología , Remoción de Dispositivos/efectos adversos , Humanos , Lentes Intraoculares/efectos adversos , Microscopía Electrónica de Rastreo , Facoemulsificación/efectos adversos , Falla de Prótesis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA