RESUMEN
PURPOSE: To determine whether the age-adjusted Charlson comorbidity index (age-CCI) in sino-orbital fungal disease patients correlates with disease-specific mortality. METHODS: Hospital billing systems at 2 academic institutions were queried for patients with ICD-9, ICD-10, and CPT codes used in fungal disease who also had orbital disease and significant visual loss. Thirty-two patients at Institution A and 18 patients at Institution B met the inclusion criteria of microbiologic or pathologic confirmation of fungal infection and completion of inpatient ophthalmology evaluation. Patients without radiographic abnormality in the sinus or orbit were excluded. Demographic, diagnostic, treatment, and outcome variables were recorded. Our primary outcome was death due to fungal disease. RESULTS: Of the 50 medical records examined, 44 patients met the criteria for fungal-related death outcome on multivariate analysis. The regression coefficient for age-CCI and fungal-related mortality was 0.242 (95% CI, 0.012-0.779) with a p value of 0.038. CONCLUSIONS: Age-CCI is significantly associated with fungal-related mortality. This relationship remains significant when controlling for 5 covariates of fungal organism phylum, presence or absence of CNS disease, exenteration, local treatment use, and presence or absence of an immunosuppressive diagnosis. Age-CCI shows promise as a clinical and research tool in the evaluation of invasive fungal disease involving the orbit.
Asunto(s)
Infecciones Fúngicas Invasoras , Enfermedades Orbitales , Comorbilidad , Hongos , Humanos , Enfermedades Orbitales/diagnóstico , Enfermedades Orbitales/epidemiología , Estudios RetrospectivosRESUMEN
SIGNIFICANCE: The complications of cosmetic iris implantation may result in irreversible vision loss. Patients who obtain these implants against general medical consensus may present to providers when sequelae develop. In symptomatic patients, providers must recognize the imminent risk to vision and mitigate further ocular damage. PURPOSE: This is an observational clinical case report of a patient with significant, progressive, vision-threatening ocular pathology from prior cosmetic iris implantation, despite medical and surgical efforts to preserve vision. CASE REPORT: A 35-year-old HIV-positive man with a history of cosmetic iris implants in India 16 months prior was referred to our center. He had a history of 4 months of steroid-refractory uveitis and secondary glaucoma, with IOP measurements of more than 50 mmHg in the outpatient setting. Slit-lamp examination revealed ciliary flush, pannus formation, corneal edema, and keratic precipitates. Optical coherence tomography suggested possible retinal nerve fiber layer loss in the left eye. He was diagnosed with uveitis and glaucoma, and after a short course of IOP-lowering medication, the implants were removed sequentially. Post-operatively, his course was complicated by IOP elevation, cataract development, and corneal decompensation. This led to bilateral Ahmed tube placement, Descemet's stripping endothelial keratoplasty of the right eye, and pending cataract surgery because of now-dense bilateral cataracts. CONCLUSIONS: This case emphasizes the vision-threatening dangers of cosmetic iris implantation. It also demonstrates that sequelae may persist and develop despite implant removal and anticipatory management. Providers managing similar patients should carefully monitor for disease progression and maintain a low threshold for referral and/or decisive surgical intervention.
Asunto(s)
Edema Corneal , Glaucoma , Adulto , Glaucoma/etiología , Glaucoma/cirugía , Humanos , Presión Intraocular , Iris/diagnóstico por imagen , Iris/cirugía , Masculino , Agudeza VisualRESUMEN
During catalysis by liver alcohol dehydrogenase (ADH), a water bound to the catalytic zinc is replaced by the oxygen of the substrates. The mechanism might involve a pentacoordinated zinc or a double-displacement reaction with participation by a nearby glutamate residue, as suggested by studies of human ADH3, yeast ADH1, and some other tetrameric ADHs. Zinc coordination and participation of water in the enzyme mechanism were investigated by X-ray crystallography. The apoenzyme and its complex with adenosine 5'-diphosphoribose have an open protein conformation with the catalytic zinc in one position, tetracoordinated by Cys-46, His-67, Cys-174, and a water molecule. The bidentate chelators 2,2'-bipyridine and 1,10-phenanthroline displace the water and form a pentacoordinated zinc. The enzyme-NADH complex has a closed conformation similar to that of ternary complexes with coenzyme and substrate analogues; the coordination of the catalytic zinc is similar to that found in the apoenzyme, except that a minor, alternative position for the catalytic zinc is â¼1.3 Å from the major position and closer to Glu-68, which could form the alternative coordination to the catalytic zinc. Complexes with NADH and N-1-methylhexylformamide or N-benzylformamide (or with NAD+ and fluoro alcohols) have the classical tetracoordinated zinc, and no water is bound to the zinc or the nicotinamide rings. The major forms of the enzyme in the mechanism have a tetracoordinated zinc, where the carboxylate group of Glu-68 could participate in the exchange of water and substrates on the zinc. Hydride transfer in the Michaelis complexes does not involve a nearby water.
Asunto(s)
Alcohol Deshidrogenasa/metabolismo , Hígado/enzimología , Zinc/metabolismo , 2,2'-Dipiridil/metabolismo , Adenosina Difosfato Ribosa/metabolismo , Alcohol Deshidrogenasa/química , Animales , Dominio Catalítico , Cristalografía por Rayos X , Formamidas/metabolismo , Caballos , Cinética , Hígado/metabolismo , Modelos Moleculares , NAD/metabolismo , Fenantrolinas/metabolismo , Unión Proteica , Conformación Proteica , Agua/química , Agua/metabolismo , Zinc/químicaRESUMEN
PURPOSE: To apply propensity score matching to compare Baerveldt glaucoma drainage implant (BGI) to Trabectome-mediated ab interno trabeculectomy (AIT). Recent data suggests that AIT can produce results similar to BGI which is traditionally reserved for more severe glaucoma. METHODS: BGI and AIT patients with at least 1 year of follow-up were included. The primary outcome measures were intraocular pressure (IOP), number of glaucoma medications, and a Glaucoma Index (GI) score. GI reflected glaucoma severity based on visual field, the number of preoperative medications, and preoperative IOP. Score matching used a genetic algorithm consisting of age, gender, type of glaucoma, concurrent phacoemulsification, baseline number of medications, and baseline IOP. Patients with neovascular glaucoma, with prior glaucoma surgery, or without a close match were excluded. RESULTS: Of 353 patients, 30 AIT patients were matched to 29 BGI patients. Baseline characteristics including, IOP, the number of glaucoma medications, type of glaucoma, the degree of VF loss and GI were not significantly different between AIT and BGI. BGI had a preoperative IOP of 21.6 ± 6.3 mmHg compared to 21.5 ± 7.4 for AIT on 2.8 ± 1.1 medications and 2.5 ± 2.3 respectively. At 30 months, the mean IOP was 15.0 ± 3.9 mmHg for AIT versus 15.0 ± 5.7 mmHg for BGI (p > 0.05), while the number of drops was 1.5 ± 1.3 for AIT (change: p = 0.001) versus 2.4 ± 1.2 for BGI (change: p = 0.17; AIT vs BGI: 0.007). Success, defined as IOP < 21 mmHg, < 20% reduction and no reoperation, was achieved at 1 year in 56% of AIT versus 55% of BGI (p > 0.05) and 50% versus 52% at 2.5 years. CONCLUSIONS: A propensity score matched comparison of AIT and BGI demonstrated a similar IOP reduction through 1 year. AIT required fewer medications.
Asunto(s)
Implantes de Drenaje de Glaucoma , Glaucoma/cirugía , Presión Intraocular , Puntaje de Propensión , Trabeculectomía/instrumentación , Campos Visuales/fisiología , Anciano , Femenino , Estudios de Seguimiento , Glaucoma/fisiopatología , Humanos , Masculino , Estudios Retrospectivos , Factores de Tiempo , Resultado del TratamientoRESUMEN
OBJECTIVE/PURPOSE: Standardization of eye care data is important for clinical interoperability and research. We aimed to address gaps in the representations of glaucoma examination concepts within Systemized Nomenclature of Medicine - Clinical Terms (SNOMED-CT), the preferred terminology of the American Academy of Ophthalmology. DESIGN: Study of data elements. METHODS: Structured eye examination data fields from 2 electronic health records (EHR) systems (Epic Systems and Medisoft) were compared against existing SNOMED-CT codes for concepts representing glaucoma examination findings. Glaucoma specialists from multiple institutions were surveyed to identify high-priority gaps in representation, which were discussed among the SNOMED International Eye Care Clinical Reference Group. Proposals for new codes to address the gaps were formulated and submitted for inclusion in SNOMED-CT. MAIN OUTCOME MEASURES: Gaps in SNOMED-CT glaucoma examination concept representations. RESULTS: We identified several gaps in SNOMED-CT regarding glaucoma examination concepts. A survey of glaucoma specialists identified high-priority data elements within the categories of tonometry and gonioscopy. For tonometry, there was consensus that we need to define new codes related to maximum intraocular pressure (IOP) and target IOP and delineate all methods of measuring IOP. These new codes were proposed and successfully added to SNOMED-CT for future use. Regarding gonioscopy, the current terminology did not include the ability to denote the gonioscopic grading system used (e.g., Shaffer or Spaeth), degree of angle pigmentation, iris configuration (except for plateau iris), and iris approach. There was also no ability to specify eye laterality or angle quadrant for gonioscopic findings. We proposed a framework for representing gonioscopic findings as observable entities in SNOMED-CT. CONCLUSION: There are existing gaps in the standardized representation of findings related to tonometry and gonioscopy within SNOMED-CT. These are important areas for evaluating clinical outcomes and enabling secondary use of EHR data for glaucoma research. This international multi-institutional collaborative process enabled identification of gaps, prioritization, and development of data standards to address these gaps. Addressing these gaps and augmenting SNOMED-CT coverage of glaucoma examination findings could enhance clinical documentation and future research efforts related to glaucoma. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
RESUMEN
RAF inhibitors have transformed treatment for patients with BRAFV600-mutant cancers, but clinical benefit is limited by adaptive induction of ERK signaling, genetic alterations that induce BRAFV600 dimerization, and poor brain penetration. Next-generation pan-RAF dimer inhibitors are limited by a narrow therapeutic index. PF-07799933 (ARRY-440) is a brain-penetrant, selective, pan-mutant BRAF inhibitor. PF-07799933 inhibited signaling in vitro, disrupted endogenous mutant-BRAF:wild-type-CRAF dimers, and spared wild-type ERK signaling. PF-07799933 ± binimetinib inhibited growth of mouse xenograft tumors driven by mutant BRAF that functions as dimers and by BRAFV600E with acquired resistance to current RAF inhibitors. We treated patients with treatment-refractory BRAF-mutant solid tumors in a first-in-human clinical trial (NCT05355701) that utilized a novel, flexible, pharmacokinetics-informed dose escalation design that allowed rapid achievement of PF-07799933 efficacious concentrations. PF-07799933 ± binimetinib was well-tolerated and resulted in multiple confirmed responses, systemically and in the brain, in patients with BRAF-mutant cancer who were refractory to approved RAF inhibitors. Significance: PF-07799933 treatment was associated with antitumor activity against BRAFV600- and non-V600-mutant cancers preclinically and in treatment-refractory patients, and PF-07799933 could be safely combined with a MEK inhibitor. The novel, rapid pharmacokinetics (PK)-informed dose escalation design provides a new paradigm for accelerating the testing of next-generation targeted therapies early in clinical development.
Asunto(s)
Resistencia a Antineoplásicos , Mutación , Neoplasias , Inhibidores de Proteínas Quinasas , Proteínas Proto-Oncogénicas B-raf , Humanos , Proteínas Proto-Oncogénicas B-raf/genética , Proteínas Proto-Oncogénicas B-raf/antagonistas & inhibidores , Animales , Inhibidores de Proteínas Quinasas/farmacocinética , Inhibidores de Proteínas Quinasas/uso terapéutico , Inhibidores de Proteínas Quinasas/administración & dosificación , Inhibidores de Proteínas Quinasas/farmacología , Ratones , Resistencia a Antineoplásicos/efectos de los fármacos , Femenino , Neoplasias/tratamiento farmacológico , Neoplasias/genética , Ensayos Antitumor por Modelo de Xenoinjerto , Masculino , Persona de Mediana Edad , Bencimidazoles/farmacocinética , Bencimidazoles/uso terapéutico , Bencimidazoles/administración & dosificación , Bencimidazoles/farmacología , Anciano , Adulto , Línea Celular TumoralRESUMEN
Purpose: The Olleyes VisuALL-K is a pediatric videogame-based static threshold perimeter using a virtual reality headset. We determined normal threshold sensitivities for the 24-2 test locations using the virtual reality perimetry (VRP) and also tested patients on the Humphrey Field Analyzer (HFA). Patient satisfaction for the two instruments was compared. Methods: This exploratory study tested 50 normal pediatric participants aged 8 to 17 years on the HFA and VRP. The main outcome measure was threshold sensitivity at the 24-2 test locations for the two instruments. Results: The mean participant age was 13.0 ± 2.6 years; 50% were female. The threshold values for VRP are reported as measured on the device and after conversion to an HFA-equivalent scale. Age-adjusted thresholds showed a mean sensitivity of 31.8 ± 1.1 dB (46.1 ± dB HFA equivalent) diminution from the maximum light intensity in the VRP and 31.0 ± 1.5 dB diminution from the maximum light intensity in the HFA; interparticipant variability in mean threshold sensitivity was 2.7 ± 0.4 dB for the VRP and 2.7 ± 0.6 dB for the HFA. The HFA demonstrated decreased threshold sensitivity with increasing eccentricity, whereas the VRP threshold did not seem to vary with eccentricity. Mild age effects on threshold sensitivity were seen in the VRP and the HFA (R2 = 0.11, P < 0.001 and R2 = 0.05, P < 0.05, respectively). The mean time to completion for VRP and HFA was 7.6 ± 1.5 and 5.3 ± 0.9 min/eye, respectively (P < 0.0001). Patient satisfaction scores favored VRP (P < 0.01) despite the longer test duration. Conclusions: The Olleyes game-based VRP and HFA can be used to map out the peripheral vision in normal children. The VRP has a higher patient satisfaction when used in children than the HFA. The portability of the test allows it to be performed in a myriad of environments, lending a flexibility that can benefit this population. Translational Relevance: This virtual reality perimetry device provides an alternative to the Humphrey Field Analyzer for children.
Asunto(s)
Realidad Virtual , Pruebas del Campo Visual , Humanos , Femenino , Niño , Masculino , Campos Visuales , Sensibilidad y Especificidad , ProteómicaRESUMEN
Rationally targeted therapies have transformed cancer treatment, but many patients develop resistance through bypass signaling pathway activation. PF-07284892 (ARRY-558) is an allosteric SHP2 inhibitor designed to overcome bypass-signaling-mediated resistance when combined with inhibitors of various oncogenic drivers. Activity in this setting was confirmed in diverse tumor models. Patients with ALK fusion-positive lung cancer, BRAFV600E-mutant colorectal cancer, KRASG12D-mutant ovarian cancer, and ROS1 fusion-positive pancreatic cancer who previously developed targeted therapy resistance were treated with PF-07284892 on the first dose level of a first-in-human clinical trial. After progression on PF-07284892 monotherapy, a novel study design allowed the addition of oncogene-directed targeted therapy that had previously failed. Combination therapy led to rapid tumor and circulating tumor DNA (ctDNA) responses and extended the duration of overall clinical benefit. SIGNIFICANCE: PF-07284892-targeted therapy combinations overcame bypass-signaling-mediated resistance in a clinical setting in which neither component was active on its own. This provides proof of concept of the utility of SHP2 inhibitors in overcoming resistance to diverse targeted therapies and provides a paradigm for accelerated testing of novel drug combinations early in clinical development. See related commentary by Hernando-Calvo and Garralda, p. 1762. This article is highlighted in the In This Issue feature, p. 1749.
Asunto(s)
Neoplasias Pulmonares , Proteínas Tirosina Quinasas , Humanos , Proteínas Tirosina Quinasas/antagonistas & inhibidores , Inhibidores de Proteínas Quinasas/farmacología , Inhibidores de Proteínas Quinasas/uso terapéutico , Proteínas Proto-Oncogénicas/genética , Neoplasias Pulmonares/tratamiento farmacológico , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/patología , Oncogenes , Atención Dirigida al PacienteRESUMEN
PURPOSE: To compare vitreous biopsy methods using analysis platforms used in proteomics biomarker discovery. METHODS: Vitreous biopsies from 10 eyes were collected sequentially using a 23-gauge needle and a 23-gauge vitreous cutter instrument. Paired specimens were evaluated by UV absorbance spectroscopy, sodium dodecyl sulfate-polyacrylamide gel electrophoresis, and liquid chromatography tandem mass spectrometry (LC-MS/MS). RESULTS: The total protein concentration obtained with a needle and vitrectomy instrument biopsy averaged 1.10 mg/mL (standard error of the mean = 0.35) and 1.13 mg/mL (standard error of the mean = 0.25), respectively. In eight eyes with low or medium viscidity, there was a very high correlation (R = 0.934) between the biopsy methods. When data from 2 eyes with high viscidity vitreous were included, the correlation was reduced (R = 0.704). The molecular weight protein sodium dodecyl sulfate-polyacrylamide gel electrophoresis profiles of paired needle and vitreous cutter samples were similar, except for a minority of pairs with single band intensity variance. Using LC-MS/MS, equivalent peptides were identified with similar frequencies (R ≥ 0.90) in paired samples. CONCLUSION: Proteins and peptides collected from vitreous needle biopsies are nearly equivalent to those obtained from a vitreous cutter instrument. This study suggests both techniques may be used for most proteomic and biomarker discovery studies of vitreoretinal diseases, although a minority of proteins and peptides may differ in concentration.
Asunto(s)
Biomarcadores/análisis , Biopsia/métodos , Proteínas del Ojo/análisis , Cuerpo Vítreo/química , Adolescente , Anciano , Biopsia/instrumentación , Cromatografía Liquida , Electroforesis en Gel de Poliacrilamida , Oftalmopatías/diagnóstico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proteómica , Espectrofotometría Ultravioleta , Espectrometría de Masas en Tándem , Vitrectomía/instrumentación , Adulto JovenRESUMEN
PURPOSE: To compare the presentation and outcomes of patients with orbital cellulitis requiring surgical intervention caused by the Group F Streptococcus (GFS) versus other bacteria. We hypothesize that patients with GFS infections have a more severe presentation and worse clinical outcomes compared to infections by other bacteria. METHODS: After Institutional Review Board approval at a large academic institutional center, 70 patients with culture-positive orbital cellulitis who required surgical intervention were identified. Clinical examinations before and after surgery as well as preoperative imaging with computed tomography and/or magnetic resonance imaging were reviewed. The study measures were preoperative and postoperative vision, motility, involved sinus disease, complications, and total hospital length of stay. Multiple imputation was used for missing data. Characteristics of patients were compared using Chi-square and Wilcoxon rank-sum. RESULTS: Nineteen patients (27%) had positive cultures for GFS and 51 patients (73%) had positive cultures for other bacterial species. There was no significant difference in visual acuity, motility, or inflammatory markers in patients with GFS compared to other patients. Patients with GFS were noted to have more sinus involvement on presentation compared to patients with other bacterial infections (P = 0.007). CONCLUSION: GFS associated orbital cellulitis is associated with significantly more sinus involvement, but has similar outcomes as orbital cellulitis from other bacterial species.
RESUMEN
PURPOSE: To evaluate the safety, reliability, and efficacy of telemedicine in delivering tertiary subspecialty glaucoma care (herein referred to as teleglaucoma) to the veteran patient population. DESIGN: Prospective case series. PARTICIPANTS: Twenty patients being referred for glaucoma subspecialist opinion participated in the pilot safety study. One hundred eighteen patients participated in the secondary study of the acceptability and service efficacy of teleglaucoma. METHODS: In the pilot study, safety was assessed by determining interobserver and intraobserver consistency (Krippendorff's α). This compared an in-person assessment by a glaucoma subspecialist with the remote assessment of 2 other glaucoma subspecialists (electronic health record alone reviewed). In the secondary study, teleglaucoma was implemented whereby testing and eye examination were carried out remotely by an optometrist or comprehensive ophthalmologist, and the clinical decision was made by the glaucoma subspecialist on review of the electronic health record alone. MAIN OUTCOME MEASURES: In the pilot study, interobserver and intraobserver consistency in making a diagnosis and treatment plan (acceptable, ≥ 0.80 Krippendorff's α). In the secondary study, patient satisfaction measured by survey, wait time for teleglaucoma opinion versus wait time for in-person opinion, and time spent on teleglaucoma consultations. RESULTS: Interobserver and intraobserver consistency showed an α of 0.86 and 0.92, respectively, for diagnosis, and 0.86 and 0.85, respectively, for treatment plan. In the secondary study, patient satisfaction was 4.55 of 5.00 (5 = maximum satisfaction; range, 3.28-4.93). Improved consultation lead time was demonstrated, with the median time for a doctor to respond to an electronic consultation being 3 days, versus 43 days for an in-person visit. Teleglaucoma also demonstrated positive benefits to the health care system by reducing the time doctors spent reviewing each patient's case (history, examination findings, imaging results, visual fields; 19 minutes for teleglaucoma consultation vs. 31 minutes for in-person evaluation). CONCLUSIONS: Decisions regarding diagnoses and treatment plans between in-person consultation and the teleglaucoma program showed high reliability. Patient satisfaction was high. Additional benefits were observed in wait time for subspecialty glaucoma opinion, efficient allocation of the doctor's time, and fiscal benefit to the health care system.
Asunto(s)
Veteranos , Hospitales , Humanos , Proyectos Piloto , Reproducibilidad de los ResultadosRESUMEN
Bacterial Rieske non-heme iron oxygenases catalyze the initial hydroxylation of aromatic hydrocarbon substrates. The structures of all three components of one such system, the toluene 2,3-dioxygenase system, have now been determined. This system consists of a reductase, a ferredoxin and a terminal dioxygenase. The dioxygenase, which was cocrystallized with toluene, is a heterohexamer containing a catalytic and a structural subunit. The catalytic subunit contains a Rieske [2Fe-2S] cluster and mononuclear iron at the active site. This iron is not strongly bound and is easily removed during enzyme purification. The structures of the enzyme with and without mononuclear iron demonstrate that part of the structure is flexible in the absence of iron. The orientation of the toluene substrate in the active site is consistent with the regiospecificity of oxygen incorporation seen in the product formed. The ferredoxin is Rieske type and contains a [2Fe-2S] cluster close to the protein surface. The reductase belongs to the glutathione reductase family of flavoenzymes and consists of three domains: an FAD-binding domain, an NADH-binding domain and a C-terminal domain. A model for electron transfer from NADH via FAD in the reductase and the ferredoxin to the terminal active-site mononuclear iron of the dioxygenase is proposed.
Asunto(s)
Complejo III de Transporte de Electrones/química , Oxigenasas de Función Mixta/metabolismo , Complejos Multienzimáticos/metabolismo , Tolueno/metabolismo , Dominio Catalítico , Cristalización , Cristalografía por Rayos X , Complejo III de Transporte de Electrones/metabolismo , Flavina-Adenina Dinucleótido/química , Hierro/química , Modelos Químicos , Complejos Multienzimáticos/química , NAD/química , Unión Proteica , Pseudomonas putida/enzimología , Especificidad por SustratoRESUMEN
OSI-930 is a novel inhibitor of the receptor tyrosine kinases Kit and kinase insert domain receptor (KDR), which is currently being evaluated in clinical studies. OSI-930 selectively inhibits Kit and KDR with similar potency in intact cells and also inhibits these targets in vivo following oral dosing. We have investigated the relationships between the potency observed in cell-based assays in vitro, the plasma exposure levels achieved following oral dosing, the time course of target inhibition in vivo, and antitumor activity of OSI-930 in tumor xenograft models. In the mutant Kit-expressing HMC-1 xenograft model, prolonged inhibition of Kit was achieved at oral doses between 10 and 50 mg/kg and this dose range was associated with antitumor activity. Similarly, prolonged inhibition of wild-type Kit in the NCI-H526 xenograft model was observed at oral doses of 100 to 200 mg/kg, which was the dose level associated with significant antitumor activity in this model as well as in the majority of other xenograft models tested. The data suggest that antitumor activity of OSI-930 in mouse xenograft models is observed at dose levels that maintain a significant level of inhibition of the molecular targets of OSI-930 for a prolonged period. Furthermore, pharmacokinetic evaluation of the plasma exposure levels of OSI-930 at these effective dose levels provides an estimate of the target plasma concentrations that may be required to achieve prolonged inhibition of Kit and KDR in humans and which would therefore be expected to yield a therapeutic benefit in future clinical evaluations of OSI-930.
Asunto(s)
Leucemia de Mastocitos/terapia , Proteínas Proto-Oncogénicas c-kit/fisiología , Quinolinas/farmacología , Tiofenos/farmacología , Receptor 2 de Factores de Crecimiento Endotelial Vascular/antagonistas & inhibidores , Administración Oral , Animales , Femenino , Humanos , Leucemia de Mastocitos/patología , Ratones , Ratones Desnudos , Quinolinas/administración & dosificación , Quinolinas/farmacocinética , Tiofenos/administración & dosificación , Tiofenos/farmacocinética , Trasplante Heterólogo , Receptor 2 de Factores de Crecimiento Endotelial Vascular/fisiologíaRESUMEN
Importance: Unverifiable publications in applications for ophthalmology residencies could be a serious concern if they represent publication dishonesty. Objective: To determine the rate of unverifiable publications among applicants offered an interview. Design: Retrospective review of 322 ophthalmology residency applications for entering classes 2012 to 2017 at Vanderbilt University School of Medicine, Nashville, Tennessee. Interventions: Full-length publications reported in the applications were searched in PubMed, Google, Google Scholar, and directly on the journal's website. Applications were deemed unverifiable if there was no record of the publication by any of these means or if substantial discrepancies existed, such as incorrect authorship, incorrect journal, or a meaningful discrepancy in title or length (full-length article vs abstract). Main Outcomes and Measures: Inability to locate publication with search, incorrect author position, applicant not listed as an author, article being an abstract and not a published paper, substantial title discrepancy suggesting an alternative project, and incorrect journal. Results: Of the 322 applicants offered interviews during the 6-year study period, 22 (6.8%) had 24 unverifiable publications. Two hundred thirty-nine of these applicants (74.2%) reported at least 1 qualifying publication; of this group, 22 (9.2%) had an unverifiable publication. The applications with unverifiable publications were evenly distributed across the years of the study (range, 2-6 per cycle; Pearson χ25 = 3.65; P = .60). Two applicants had 2 unverifiable publications each. Two of the 22 applicants (9.1%) with unverifiable publications were graduates of medical schools outside the United States. Among the unverifiable publications, the most common reason was inability to locate the publication (13 [54%]). Additional issues included abstract rather than full-length publication (5 [20.8%]), incorrect author position (4 [16.7%]), applicant not listed as an author on the publication (1 [4.2%]), and substantial title discrepancy (1 [4.2%]). One listed publication had an incorrect author position and incorrect journal (1 [4.2%]). Conclusions and Relevance: Unverifiable publications among ophthalmology residency applicants is a persistent problem. Possible strategies to modify the review process include asking applicants to provide copies of their full-length works or the relevant PMCID (PubMed Central reference number) or DOI (digital object identifier) for their publications.
Asunto(s)
Internado y Residencia , Solicitud de Empleo , Oftalmología/educación , Publicaciones/estadística & datos numéricos , Mala Conducta Científica , Adulto , Autoria , Bibliografías como Asunto , Estudios Transversales , Femenino , Humanos , Entrevistas como Asunto , Masculino , Estudios RetrospectivosRESUMEN
PURPOSE: To apply propensity score matching to Ahmed glaucoma drainage implants (AGI) to trabectome-mediated ab interno trabeculectomy (AIT). Recent data suggest that AIT can produce results similar to AGI traditionally reserved for more severe glaucoma. METHODS: AGI and AIT patients with at least 1 year of follow-up were included. The primary outcome measures were intraocular pressure (IOP), glaucoma medications, and a Glaucoma Index (GI) score. GI reflected glaucoma severity based on visual field, the number of preoperative medications, and preoperative IOP. Score matching used a genetic algorithm consisting of age, sex, type of glaucoma, concurrent phacoemulsification, baseline number of medications, and baseline IOP. Patients without a close match were excluded. RESULTS: Of 152 patients, 34 AIT patients were matched to 32 AGI patients. Baseline characteristics including ethnicity, IOP, the number of medications, glaucoma type, the degree of visual field loss and GI were not significantly different between AIT and AGI. AIT had a preoperative IOP of 23.6±8.1 mm Hg compared with 26.5+10.6 mm Hg for AGI. At 12 months, the mean IOP was 15.0±9 mm Hg for AIT versus 15.0±4 mm Hg for AGI (P=0.8), whereas the number of drops was 2.3±2.2 for AIT versus 3.6±1.3 for AGI (P=0.016). Only 6 AIT patients (17.6%) required further surgery within the first 12 months versus 9 (28%) for AGI. Success, defined as IOP<21 mm Hg, <20% reduction and no reoperation, was achieved in 76% of AIT versus 69% of AGI (P=0.48). Complications occurred in 13% of AGI and 0.8% of AIT. CONCLUSIONS: A propensity score-matched comparison of AIT and AGI showed an equivalent IOP reduction through 1 year. Surprisingly, the AGI group required more glaucoma medications than the AIT group at 6 and 12 months.
Asunto(s)
Implantes de Drenaje de Glaucoma , Glaucoma/cirugía , Malla Trabecular/cirugía , Trabeculectomía/métodos , Anciano , Femenino , Glaucoma/clasificación , Glaucoma/fisiopatología , Humanos , Presión Intraocular/fisiología , Masculino , Persona de Mediana Edad , Facoemulsificación/métodos , Puntaje de Propensión , Implantación de Prótesis , Estudios Retrospectivos , Tonometría Ocular , Resultado del Tratamiento , Pruebas del Campo Visual , Campos Visuales/fisiologíaRESUMEN
BACKGROUND: The initial step involved in oxidative hydroxylation of monoaromatic and polyaromatic compounds by the microorganism Sphingobium yanoikuyae strain B1 (B1), previously known as Sphingomonas yanoikuyae strain B1 and Beijerinckia sp. strain B1, is performed by a set of multiple terminal Rieske non-heme iron oxygenases. These enzymes share a single electron donor system consisting of a reductase and a ferredoxin (BPDO-FB1). One of the terminal Rieske oxygenases, biphenyl 2,3-dioxygenase (BPDO-OB1), is responsible for B1's ability to dihydroxylate large aromatic compounds, such as chrysene and benzo[a]pyrene. RESULTS: In this study, crystal structures of BPDO-OB1 in both native and biphenyl bound forms are described. Sequence and structural comparisons to other Rieske oxygenases show this enzyme to be most similar, with 43.5 % sequence identity, to naphthalene dioxygenase from Pseudomonas sp. strain NCIB 9816-4. While structurally similar to naphthalene 1,2-dioxygenase, the active site entrance is significantly larger than the entrance for naphthalene 1,2-dioxygenase. Differences in active site residues also allow the binding of large aromatic substrates. There are no major structural changes observed upon binding of the substrate. BPDO-FB1 has large sequence identity to other bacterial Rieske ferredoxins whose structures are known and demonstrates a high structural homology; however, differences in side chain composition and conformation around the Rieske cluster binding site are noted. CONCLUSION: This is the first structure of a Rieske oxygenase that oxidizes substrates with five aromatic rings to be reported. This ability to catalyze the oxidation of larger substrates is a result of both a larger entrance to the active site as well as the ability of the active site to accommodate larger substrates. While the biphenyl ferredoxin is structurally similar to other Rieske ferredoxins, there are distinct changes in the amino acids near the iron-sulfur cluster. Because this ferredoxin is used by multiple oxygenases present in the B1 organism, this ferredoxin-oxygenase system provides the structural platform to dissect the balance between promiscuity and selectivity in protein-protein electron transport systems.
Asunto(s)
Ferredoxinas/química , Proteínas Hierro-Azufre/química , Oxigenasas/química , Sphingobacterium/genética , Sitios de Unión , Ferredoxinas/metabolismo , Histidina , Hierro/análisis , Hierro/metabolismo , Proteínas Hierro-Azufre/metabolismo , Cinética , Oxigenasas/metabolismo , Unión ProteicaRESUMEN
PURPOSE: To compare intraocular pressure (IOP) after trabectome-mediated ab interno trabeculectomy surgery in phakic patients (T) and trabectome with same session phacoemulsification (PT) using Coarsened Exact Matching. Although phacoemulsification is associated with IOP reduction when performed on its own, it is not known how much it contributes in PT. METHODS: Subjects were divided into phakic T and PT. Exclusion criteria were follow-up for <12 months and additional glaucoma surgery. Demographics were compared by the Mann-Whitney U test and chi-squared test for continuous and categorical variables, respectively. Multiple imputation was utilized to avoid eliminating data with missing values. Groups were then matched using Coarsened Exact Matching based on age, race, type of glaucoma, baseline IOP, and number of preoperative glaucoma medications. Univariate linear regression was used to examine IOP reduction after surgery; those variables that were statistically significant were included in the final multivariate regression model. RESULTS: A total of 753 cases were included (T: 255, PT: 498). When all variables except for age were kept constant, there was an additional IOP reduction of 0.05±0.01 mmHg conferred for every yearly increment in age. Every 1 mmHg increase in baseline IOP correlated to an additional IOP reduction of 0.80±0.02 mmHg. Phacoemulsification was not found to be a statistically significant contributor to IOP when comparing T and PT (p≥0.05). T had a 21% IOP reduction to 15.9±3.5 mmHg (p<0.01) while PT had an 18% reduction to 15.5±3.6 mmHg (p<0.01). Number of medications decreased (p<0.01) in both groups from 2.4±1.2 to 1.9±1.3 and from 2.3±1.1 to 1.7±1.3, respectively. CONCLUSION: Phacoemulsification does not make a significant contribution to postoperative IOP or number of medications when combined with trabectome surgery in phakic patients.
Asunto(s)
Facoemulsificación , Trabeculectomía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Glaucoma de Ángulo Abierto/fisiopatología , Glaucoma de Ángulo Abierto/cirugía , Humanos , Presión Intraocular , Masculino , Persona de Mediana Edad , Facoemulsificación/métodos , Trabeculectomía/métodos , Resultado del Tratamiento , Adulto JovenRESUMEN
PURPOSE: To compare intraocular pressure (IOP) reduction and to develop a predictive surgery calculator based on the results between trabectome-mediated ab interno trabeculectomy in pseudophakic patients versus phacoemulsification combined with trabectome-mediated ab interno trabeculectomy in phakic patients. METHODS: This observational surgical cohort study analyzed pseudophakic patients who received trabectome-mediated ab interno trabeculectomy (AIT) or phacoemulsification combined with AIT (phaco-AIT). Follow up for less than 12 months or neovascular glaucoma led to exclusion. Missing data was imputed by generating 5 similar but non-identical datasets. Groups were matched using Coarsened Exact Matching based on age, gender, type of glaucoma, race, preoperative number of glaucoma medications and baseline intraocular pressure (IOP). Linear regression was used to examine the outcome measures consisting of IOP and medications. RESULTS: Of 949 cases, 587 were included consisting of 235 AIT and 352 phaco-AIT. Baseline IOP between groups was statistically significant (p≤0.01) in linear regression models and was minimized after Coarsened Exact Matching. An increment of 1 mmHg in baseline IOP was associated with a 0.73±0.03 mmHg IOP reduction. Phaco-AIT had an IOP reduction that was only 0.73±0.32 mmHg greater than that of AIT. The resulting calculator to determine IOP reduction consisted of the formula -13.54+0.73 × (phacoemulsification yes:1, no:0) + 0.73 × (baseline IOP) + 0.59 × (secondary open angle glaucoma yes:1, no:0) + 0.03 × (age) + 0.09 × (medications). CONCLUSIONS: This predictive calculator for minimally invasive glaucoma surgery can assist clinical decision making. Only a small additional IOP reduction was observed when phacoemulsification was added to AIT. Patients with a higher baseline IOP had a greater IOP reduction.