1.
Proc Natl Acad Sci U S A ; 121(34): e2405628121, 2024 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-39141355

RESUMEN

Fluorescence guidance is routinely used in surgery to enhance perfusion contrast in multiple types of diseases. Pressure-enhanced sensing of tissue oxygenation (PRESTO) via fluorescence is a technique extensively analyzed here, that uses an FDA-approved human precursor molecule, 5-aminolevulinic acid (ALA), to stimulate a unique delayed fluorescence signal that is representative of tissue hypoxia. The ALA precontrast agent is metabolized in most tissues into a red fluorescent molecule, protoporphyrin IX (PpIX), which has both prompt fluorescence, indicative of the concentration, and a delayed fluorescence, that is amplified in low tissue oxygen situations. Applied pressure from palpation induces transient capillary stasis and a resulting transient PRESTO contrast, dominant when there is near hypoxia. This study examined the kinetics and behavior of this effect in both normal and tumor tissues, with a prolonged high PRESTO contrast (contrast to background of 7.3) across 5 tumor models, due to sluggish capillaries and inhibited vasodynamics. This tissue function imaging approach is a fundamentally unique tool for real-time palpation-induced tissue response in vivo, relevant for chronic hypoxia, such as vascular diseases or oncologic surgery.


Asunto(s)
Ácido Aminolevulínico , Neoplasias , Oxígeno , Protoporfirinas , Animales , Oxígeno/metabolismo , Ratones , Ácido Aminolevulínico/metabolismo , Neoplasias/metabolismo , Neoplasias/cirugía , Protoporfirinas/metabolismo , Humanos , Presión , Porfirinas/metabolismo
2.
J Appl Clin Med Phys ; 22(9): 252-261, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34409766

RESUMEN

PURPOSE: Demonstrate a novel phantom design using a remote camera imaging method capable of concurrently measuring the position of the x-ray isocenter and the magnetic resonance imaging (MRI) isocenter on an MR-linac. METHODS: A conical frustum with distinct geometric features was machined out of plastic. The phantom was submerged in a small water tank, and aligned using room lasers on a MRIdian MR-linac (ViewRay Inc., Cleveland, OH). The phantom physical isocenter was visualized in the MR images and related to the DICOM coordinate isocenter. To view the x-ray isocenter, an intensified CMOS camera system (DoseOptics LLC., Hanover, NH) was placed at the foot of the treatment couch, and centered such that the optical axis of the camera was coincident with the central axis of the treatment bore. Two or four 8.3mm x 24.1cm beams irradiated the phantom from cardinal directions, producing an optical ring on the conical surface of the phantom. The diameter of the ring, measured at the peak intensity, was compared to the known diameter at the position of irradiation to determine the Z-direction offset of the beam. A star-shot method was employed on the front face of the frustum to determine X-Y alignment of the MV beam. Known shifts were applied to the phantom to establish the sensitivity of the method. RESULTS: Couch translations, demonstrative of possible isocenter misalignments, on the order of 1mm were detectable for both the radiotherapy and MRI isocenters. Data acquired on the MR-linac demonstrated an average error of 0.28mm(N=10, R2 =0.997, σ=0.37mm) in established Z displacement, and 0.10mm(N=5, σ=0.34mm) in XY directions of the radiotherapy isocenter. CONCLUSIONS: The phantom was capable of measuring both the MRI and radiotherapy treatment isocenters. This method has the potential to be of use in MR-linac commissioning, and could be streamlined to be valuable in daily constancy checks of isocenter coincidence.


Asunto(s)
Aceleradores de Partículas , Radioterapia Guiada por Imagen , Humanos , Imagen por Resonancia Magnética , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador
3.
Opt Lett ; 45(3): 664, 2020 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-32004278

RESUMEN

This publisher's note contains corrections to Opt. Lett.45, 284 (2020)OPLEDP0146-959210.1364/OL.45.000284.

4.
Opt Lett ; 45(22): 6130-6133, 2020 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-33186932

RESUMEN

Cherenkov light induced from megavolt (MV) X-rays during external beam radiotherapy serves as an internal light source to excite phosphors or fluorophores within biological tissues for molecular imaging. The broad spectrum of Cherenkov light leads to significant spectral overlap with any luminescence emission and, to overcome this problem, a single pixel hyperspectral imaging methodology was demonstrated here by coupling the detection with light sheet scanning and filtered back projection reconstruction of hyperspectral images. Thin scanned sheets of MV X-rays produce Cherenkov light to illuminate the planes deep within the tissue-simulating media. A fluorescence probe was excited by Cherenkov light, and a complete hyperspectral sinogram of the data was obtained through translation and rotation of the beam. Hyperspectral 2D images finally were reconstructed. Through this approach of spectral unmixing, it was possible to resolve hyperspectral images of both the Cherenkov and resulting fluorescence intensity from molecular sensors.


Asunto(s)
Imagen Óptica/instrumentación , Aceleradores de Partículas , Procesamiento de Imagen Asistido por Computador , Propiedades de Superficie , Rayos X
5.
Opt Lett ; 45(13): 3761-3764, 2020 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-32630948

RESUMEN

Fluorescence imaging is severely limited by the background and autofluorescence of tissues for in vivo detection of circulating tumor cells (CTCs). Time-gated luminescence (TGL) imaging, in combination with luminescent probes that possess hundreds of microsecond emission lifetimes, can be used to effectively suppress this background, which has predominantly nanosecond lifetimes. This Letter demonstrates the feasibility of TGL imaging using luminescent probes for the in vivo real time imaging and tracking of single CTCs circulating freely in the blood vessels with higher accuracy given by substantially higher signal-to-noise ratio. The luminescent probe used in this Letter was a commercial Eu3+ chelate (EuC) nanosphere with a super-long lifetime of near 800 µs, which enabled TGL imaging to achieve background-free detection with ∼5 times higher SNR versus steady state. Phantom and in vivo mouse studies indicated that EuC labeled tumor cells moving in medium or bloodstream at the speed of 1-2 mm/s could be captured in real time.


Asunto(s)
Luminiscencia , Células Neoplásicas Circulantes/patología , Imagen Óptica/métodos , Análisis de la Célula Individual/métodos , Animales , Línea Celular Tumoral , Humanos , Ratones , Relación Señal-Ruido , Factores de Tiempo
6.
J Appl Clin Med Phys ; 21(6): 158-162, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32306551

RESUMEN

PURPOSE: The novel scintillator-based system described in this study is capable of accurately and remotely measuring surface dose during Total Skin Electron Therapy (TSET); this dosimeter does not require post-exposure processing or annealing and has been shown to be re-usable, resistant to radiation damage, have minimal impact on surface dose, and reduce chances of operator error compared to existing technologies e.g. optically stimulated luminescence detector (OSLD). The purpose of this study was to quantitatively analyze the workflow required to measure surface dose using this new scintillator dosimeter and compare it to that of standard OSLDs. METHODS: Disc-shaped scintillators were attached to a flat-faced phantom and a patient undergoing TSET. Light emission from these plastic discs was captured using a time-gated, intensified, camera during irradiation and converted to dose using an external calibration factor. Time required to complete each step (daily QA, dosimeter preparation, attachment, removal, registration, and readout) of the scintillator and OSLD surface dosimetry workflows was tracked. RESULTS: In phantoms, scintillators and OSLDs surface doses agreed within 3% for all data points. During patient imaging it was found that surface dose measured by OSLD and scintillator agreed within 5% and 3% for 35/35 and 32/35 dosimetry sites, respectively. The end-to-end time required to measure surface dose during phantom experiments for a single dosimeter was 78 and 202 sec for scintillator and OSL dosimeters, respectively. During patient treatment, surface dose was assessed at 7 different body locations by scintillator and OSL dosimeters in 386 and 754 sec, respectively. CONCLUSION: Scintillators have been shown to report dose nearly twice as fast as OSLDs with substantially less manual work and reduced chances of human error. Scintillator dose measurements are automatically saved to an electronic patient file and images contain a permanent record of the dose delivered during treatment.


Asunto(s)
Electrones , Dosímetros de Radiación , Humanos , Fantasmas de Imagen , Radiometría , Flujo de Trabajo
7.
Opt Lett ; 44(7): 1552-1555, 2019 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-30933088

RESUMEN

Cherenkov-excited luminescence scanned imaging (CELSI) is achieved with a clinical linear accelerator during external beam radiotherapy to map out molecular luminescence intensity or lifetime in tissue. In order to realize a deeper imaging depth with a reasonable spatial resolution in CELSI, we optimized the original scanning procedure to complete this in a way similar to x-ray computed tomography and with image reconstruction from maximum-likelihood expectation maximization and multi-pinhole irradiation for parallelization. Resolution phantom studies showed that a 0.3 mm diameter capillary tube containing 0.01 nM luminescent nanospheres could be recognized at a depth of 21 mm into tissue-like media. Small animal imaging with a 1 mm diameter cylindrical target demonstrated that fast 3D data acquisition can be achieved by this multi-pinhole collimator approach to image high-resolution luminescence through a whole animal.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Luminiscencia , Tomografía/métodos , Animales , Femenino , Ratones , Fantasmas de Imagen
8.
Opt Lett ; 43(16): 3854-3857, 2018 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-30106900

RESUMEN

Cherenkov emission induced by external beam radiation from a clinical linear accelerator has been shown in preclinical molecular imaging and clinical imaging. The broad spectrum Cherenkov emission should have a short wavelength infrared (SWIR, 1000-1700 nm) component, as predicted theoretically. To the best of our knowledge, this Letter is the first experimental observation of this SWIR Cherenkov emission induced by external beam radiation. The measured spectrum of SWIR Cherenkov emission matches the theoretical prediction, with a fluence rate near one-third of the visible and near-infrared red emissions (Vis-NIR, 400-900 nm). Imaging in water-based phantoms and biological tissues indicates that there is a sufficient fluence rate for radiotherapy dosimetry applications. The spatial resolution is improved approximately 5.3 times with SWIR Cherenkov emission detection versus Vis-NIR Cherenkov emission, which provides some improvement in the potential for higher resolution Cherenkov emission dosimetry and molecular sensing during clinical radiotherapy by imaging with SWIR wavelengths.

9.
Opt Lett ; 41(13): 2986-9, 2016 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-27367082

RESUMEN

Light scattering leads to a severe loss of axial and transverse resolution with depth into tissue, limiting accuracy and value of biomedical luminescence imaging techniques. High-resolution imaging beyond a few-millimeter depth is prohibited because diffusive transport dominates beyond a few scattering distances. In this study, light sheet imaging through scattering media is demonstrated using a radiotherapy linear accelerator to deliver well-defined thin scanned sheets of x-rays. These sheets produce Cherenkov light within the medium, which in turn excites luminescence of an optical probe across the sheet plane. This luminescence can then be imaged by an intensified camera positioned perpendicular to the sheet plane. The precise knowledge of the light sheet position within the medium allowed for efficient attenuation correction of the signal with depth as well as spatial deconvolution of the excitation light. Together these methods allowed for the first time, to the best of our knowledge, high-resolution imaging of tissue-equivalent phantoms up to 3 cm thick, yielding the precise position and shape of luminescent lesions located deep in tissue without the need for nonlinear image reconstruction.

10.
Nanotechnology ; 25(45): 455501, 2014 Nov 14.
Artículo en Inglés | MEDLINE | ID: mdl-25327948

RESUMEN

We prepare InGaN/GaN multiple quantum well (MQW) structure by metal-organic vapour phase epitaxy and characterize it by fine XRD measurements. We demonstrate its suitability for scintillator application including a unique measurement of wavelength-resolved scintillation response under nanosecond pulse soft x-ray source in extended dynamical and time scales. The photoluminescence and radioluminescence were measured: we have shown that the ratio of the intensity of quantum well (QW) exciton luminescence to the intensity of the yellow luminescence (YL) band IQW/IYL depends strongly on the type and intensity of excitation. Slower scintillation decay measured at YL band maximum confirmed the presence of several radiative recombination centres responsible for wide YL band, which also partially overlap with the QW peak. Further improvements of the structure are suggested, but even the presently reported decay characteristics of the excitonic emission in MQW are better compared to the currently widely used single crystal YAP:Ce or YAG:Ce scintillators. Thus, such a type of a semiconductor scintillator is highly promising for fast detection of soft x-ray and related beam diagnostics.

11.
Artículo en Inglés | MEDLINE | ID: mdl-38703954

RESUMEN

PURPOSE: Large, rapid extracellular oxygen transients (ΔpO2) have been measured in vivo during ultra-high dose rate radiation therapy; however, it has been unclear if they match intracellular oxygen levels. Here, the endogenously produced protoporphyrin IX (PpIX) delayed fluorescence signal was measured as an intracellular in-vivo oxygen sensor to quantify these transients, with direct comparison to extracellular pO2. Intracellular ΔpO2 is closer to the cellular DNA, the site of major radiobiological damage, and therefore should help elucidate radiochemical mechanisms of the FLASH effect and potentially be translated to human tissue measurement. METHODS AND MATERIALS: PpIX was induced in mouse skin through intraperitoneal injection of 250 mg/kg of aminolevulinic acid. The animals were also administered a 50 µL intradermal injection of 10 µM oxyphor G4 (PdG4) for phosphorescence lifetime pO2 measurement. Paired oxygen transients were quantified in leg or flank tissues while delivering 10 MeV electrons in 3 µs pulses at 360 Hz for a total dose of 10 to 28 Gy. RESULTS: Transient reductions in pO2 were quantifiable in both PpIX delayed fluorescence and oxyphor phosphorescence, corresponding to intracellular and extracellular pO2 values, respectively. Reponses were quantified for 10, 22, and 28 Gy doses, with ΔpO2 found to be proportional to the dose on average. The ΔpO2 values were dependent on initial pO2 in a logistic function. The average and standard deviations in ΔpO2 per dose were 0.56 ± 0.18 mm Hg/Gy and 0.43 ± 0.06 mm Hg/Gy for PpIX and oxyphor, respectively, for initial pO2 > 20 mm Hg. Although there was large variability in the individual animal measurements of ΔpO2, the average values demonstrated a direct and proportional correlation between intracellular and extracellular pO2 changes, following a linear 1:1 relationship. CONCLUSIONS: A fundamentally new approach to measuring intracellular oxygen depletion in living tissue showed that ΔpO2 transients seen during ultra-high dose rate radiation therapy matched those quantified using extracellular oxygen measurement. This approach could be translated to humans to quantify intracellular ΔpO2. The measurement of these transients could potentially allow the estimation of intracellular reactive oxygen species production.

12.
Artículo en Inglés | MEDLINE | ID: mdl-39182736

RESUMEN

PURPOSE: This study investigates scintillation dosimetry coupled with Cherenkov imaging for in vivo dose monitoring during whole breast radiotherapy (WBRT). Given recent observations of excess dose to the contralateral breast (CB), in vivo dosimetry (IVD) could help ensure accurate dose delivery and decrease risks of secondary cancer. This work presents a rapid, streamlined alternative to traditional IVD, providing direct visualization of measurement location relative to the treatment field on the patient. METHODS AND MATERIALS: 10 WBRT patients consented under an IRB-approved protocol were monitored with scintillation dosimetry and always-on Cherenkov imaging, on both their treated and CB for one to three fractions. Scintillator dosimeters, small plastic discs 1mm thick and 15mm in diameter, were calibrated against optically-stimulated luminescent dosimeters (OSLDs) to generate an integral output-to-dose conversion, where integral output is measured in post-processing through a custom fitting algorithm. The discs have been extensively characterized in a previous study for various treatment conditions including beam energy and treatment geometry. RESULTS: N=44 dosimetry measurements were evaluated, including 22 treated breast and 22 CB measurements. Following integral output-to-dose calibration, in vivo scintillator dosimeters exhibited high linearity (R2=0.99) with paired OSLD readings across all patients. The difference between scintillation and OSLD dose measurements averaged 2.8% of the prescribed dose, or an absolute dose difference of approximately 7 cGy. CONCLUSIONS: Integration of scintillation dosimetry with Cherenkov imaging offers an accurate, rapid alternative for in vivo dose verification in WBRT, circumventing the limitations of conventional point dosimeters. The additional benefit of visualizing measurement locations relative to the treatment field provides users an enhanced understanding of results and allows for detection of high dose gradients. Future work will explore the applicability of this technique across a broader range of radiotherapy treatments, aiming to streamline IVD practices.

13.
Med Phys ; 51(7): 5119-5129, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38569159

RESUMEN

BACKGROUND: Dosimetry in pre-clinical FLASH studies is essential for understanding the beam delivery conditions that trigger the FLASH effect. Resolving the spatial and temporal characteristics of proton pencil beam scanning (PBS) irradiations with ultra-high dose rates (UHDR) requires a detector with high spatial and temporal resolution. PURPOSE: To implement a novel camera-based system for time-resolved two-dimensional (2D) monitoring and apply it in vivo during pre-clinical proton PBS mouse irradiations. METHODS: Time-resolved 2D beam monitoring was performed with a scintillation imaging system consisting of a 1 mm thick transparent scintillating sheet, imaged by a CMOS camera. The sheet was placed in a water bath perpendicular to a horizontal PBS proton beam axis. The scintillation light was reflected through a system of mirrors and captured by the camera with 500 frames per second (fps) for UHDR and 4 fps for conventional dose rates. The raw images were background subtracted, geometrically transformed, flat field corrected, and spatially filtered. The system was used for 2D spot and field profile measurements and compared to radiochromic films. Furthermore, spot positions were measured for UHDR irradiations. The measured spot positions were compared to the planned positions and the relative instantaneous dose rate to equivalent fiber-coupled point scintillator measurements. For in vivo application, the scintillating sheet was placed 1 cm upstream the right hind leg of non-anaesthetized mice submerged in the water bath. The mouse leg and sheet were both placed in a 5 cm wide spread-out Bragg peak formed from the mono-energetic proton beam by a 2D range modulator. The mouse leg position within the field was identified for both conventional and FLASH irradiations. For the conventional irradiations, the mouse foot position was tracked throughout the beam delivery, which took place through repainting. For FLASH irradiations, the delivered spot positions and relative instantaneous dose rate were measured. RESULTS: The pixel size was 0.1 mm for all measurements. The spot and field profiles measured with the scintillating sheet agreed with radiochromic films within 0.4 mm. The standard deviation between measured and planned spot positions was 0.26 mm and 0.35 mm in the horizontal and vertical direction, respectively. The measured relative instantaneous dose rate showed a linear relation with the fiber-coupled scintillator measurements. For in vivo use, the leg position within the field varied between mice, and leg movement up to 3 mm was detected during the prolonged conventional irradiations. CONCLUSIONS: The scintillation imaging system allowed for monitoring of UHDR proton PBS delivery in vivo with 0.1 mm pixel size and 2 ms temporal resolution. The feasibility of instantaneous dose rate measurements was demonstrated, and the system was used for validation of the mouse leg position within the field.


Asunto(s)
Terapia de Protones , Conteo por Cintilación , Animales , Ratones , Conteo por Cintilación/instrumentación , Terapia de Protones/instrumentación , Factores de Tiempo , Radiometría/instrumentación , Radiometría/métodos , Dosificación Radioterapéutica , Protones
14.
Med Phys ; 51(8): 5754-5763, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38598093

RESUMEN

BACKGROUND: While careful planning and pre-treatment checks are performed to ensure patient safety during external beam radiation therapy (EBRT), inevitable daily variations mean that in vivo dosimetry (IVD) is the only way to attain the true delivered dose. Several countries outside the US require daily IVD for quality assurance. However, elsewhere, the manual labor and time considerations of traditional in vivo dosimeters may be preventing frequent use of IVD in the clinic. PURPOSE: This study expands upon previous research using plastic scintillator discs for optical dosimetry for electron therapy treatments. We present the characterization of scintillator discs for in vivo x-ray dosimetry and describe additional considerations due to geometric complexities. METHODS: Plastic scintillator discs were coated with reflective white paint on all sides but the front surface. An anti-reflective, matte coating was applied to the transparent face to minimize specular reflection. A time-gated iCMOS camera imaged the discs under various irradiation conditions. In post-processing, background-subtracted images of the scintillators were fit with Gaussian-convolved ellipses to extract several parameters, including integral output, and observation angle. RESULTS: Dose linearity and x-ray energy independence were observed, consistent with ideal characteristics for a dosimeter. Dose measurements exhibited less than 5% variation for incident beam angles between 0° and 75° at the anterior surface and 0-60 ∘ $^\circ $ at the posterior surface for exit beam dosimetry. Varying the angle between the disc surface and the camera lens did not impact the integral output for the same dose up to 55°. Past this point, up to 75°, there is a sharp falloff in response; however, a correction can be used based on the detected width of the disc. The reproducibility of the integral output for a single disc is 2%, and combined with variations from the gantry angle, we report the accuracy of the proposed scintillator disc dosimeters as ±5.4%. CONCLUSIONS: Plastic scintillator discs have characteristics that are well-suited for in vivo optical dosimetry for x-ray radiotherapy treatments. Unlike typical point dosimeters, there is no inherent readout time delay, and an optical recording of the measurement is saved after treatment for future reference. While several factors influence the integral output for the same dose, they have been quantified here and may be corrected in post-processing.


Asunto(s)
Fotones , Conteo por Cintilación , Fotones/uso terapéutico , Conteo por Cintilación/instrumentación , Factores de Tiempo , Radiometría/instrumentación , Dosificación Radioterapéutica , Humanos , Radioterapia/métodos , Radioterapia/instrumentación
15.
Med Phys ; 2024 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-38860497

RESUMEN

BACKGROUND: Ultra-high dose rate radiotherapy (UHDR-RT) has demonstrated normal tissue sparing capabilities, termed the FLASH effect; however, available dosimetry tools make it challenging to characterize the UHDR beams with sufficiently high concurrent spatial and temporal resolution. Novel dosimeters are needed for safe clinical implementation and improved understanding of the effect of UHDR-RT. PURPOSE: Ultra-fast scintillation imaging has been shown to provide a unique tool for spatio-temporal dosimetry of conventional cyclotron pencil beam scanning (PBS) deliveries, indicating the potential use for characterization of UHDR PBS proton beams. The goal of this work is to introduce this novel concept and demonstrate its capabilities in recording high-resolution dose rate maps at FLASH-capable proton beam currents, as compared to log-based dose rate calculation, internally developed UHDR beam simulation, and a fast point detector (EDGE diode). METHODS: The light response of a scintillator sheet located at isocenter and irradiated by PBS proton fields (40-210 nA, 250 MeV) was imaged by an ultra-fast iCMOS camera at 4.5-12 kHz sampling frequency. Camera sensor and image intensifier gain were optimized to maximize the dynamic range; the camera acquisition rate was also varied to evaluate the optimal sampling frequency. Large field delivery enabled flat field acquisition for evaluation of system response homogeneity. Image intensity was calibrated to dose with film and the recorded spatio-temporal data was compared to a PPC05 ion chamber, log-based reconstruction, and EDGE diode. Dose and dose rate linearity studies were performed to evaluate agreement under various beam conditions. Calculation of full-field mean and PBS dose rate maps were calculated to highlight the importance of high resolution, full-field information in UHDR studies. RESULTS: Camera response was linear with dose (R2 = 0.997) and current (R22 = 0.98) in the range from 2-22 Gy and 40-210 nA, respectively, when compared to ion chamber readings. The deviation of total irradiation time calculated with the imaging system from the log file recordings decreased from 0.07% to 0.03% when imaging at 12 kfps versus 4.5 kfps. Planned and delivered spot positions agreed within 0.2 ± $\pm$ 0.1 mm and total irradiation time agreed within 0.2 ± $\pm$ 0.2 ms when compared with the log files, indicating the high concurrent spatial and temporal resolution. For all deliveries, the PBS dose rate measured at the diode location agreed between the imaging and the diode within 3% ± $\pm$ 2% and with the simulation within 5% ± $\pm$ 3% CONCLUSIONS: Full-field mapping of dose and dose rate is imperative for complete understanding of UHDR PBS proton dose delivery. The high linearity and various spatiotemporal metric reporting capabilities confirm the continued use of this camera system for UHDR beam characterization, especially for spatially resolved dose rate information.

16.
Int J Radiat Oncol Biol Phys ; 119(4): 1317-1325, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38552990

RESUMEN

PURPOSE: In this study, a C-series linear accelerator was configured to enable rapid and reliable conversion between the production of conventional electron beams and an ultrahigh-dose-rate (UHDR) electron beamline to the treatment room isocenter for FLASH radiation therapy. Efforts to tune the beam resulted in a consistent, stable UHDR beamline. METHODS AND MATERIALS: The linear accelerator was configured to allow for efficient switching between conventional and modified electron output modes within 2 minutes. Additions to the air system allow for retraction of the x-ray target from the beamline when the 10 MV photon mode is selected. With the carousel set to an empty port, this grants access to the higher current pristine electron beam normally used to produce clinical photon fields. Monitoring signals related to the automatic frequency control system allows for tuning of the waveguide while the machine is in a hold state so a stable beam is produced from the initial pulse. A pulse counting system implemented on an field-programmable gate array-based controller platform controls the delivery to a desired number of pulses. Beam profiles were measured with Gafchromic film. Pulse-by-pulse dosimetry was measured using a custom electrometer designed around the EDGE diode. RESULTS: This method reliably produces a stable UHDR electron beam. Open-field measurements of the 16-cm full-width, half-maximum gaussian beam saw average dose rates of 432 Gy/s at treatment isocenter. Pulse overshoots were limited and ramp up was eliminated. Over the last year, there have been no recorded incidents that resulted in machine downtime due to the UHDR conversions. CONCLUSIONS: Stable 10 MeV UHDR beams were generated to produce an average dose rate of 432 Gy/s at the treatment room isocenter. With a reliable pulse-counting beam control system, consistent doses can be delivered for FLASH experiments with the ability to accommodate a wide range of field sizes, source-to-surface distances, and other experimental apparatus that may be relevant for future clinical translation.


Asunto(s)
Electrones , Aceleradores de Partículas , Fotones , Aceleradores de Partículas/instrumentación , Electrones/uso terapéutico , Fotones/uso terapéutico , Diseño de Equipo , Dosificación Radioterapéutica , Factores de Tiempo , Radioterapia de Alta Energía/instrumentación , Radioterapia de Alta Energía/métodos
17.
Phys Med Biol ; 69(7)2024 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-38422545

RESUMEN

Objective. Imaging of optical photons emitted from tissue during radiotherapy is a promising technique for real-time visualization of treatment delivery, offering applications in dose verification, treatment monitoring, and retrospective treatment plan comparison. This research aims to explore the feasibility of intensified imaging of tissue luminescence during proton therapy (PT), under both conventional and ultra-high dose rate (UHDR) conditions.Approach. Conventional and UHDR pencil beam scanning (PBS) PT irradiation of freshex vivoporcine tissue and tissue-mimicking plastic phantom was imaged using intensified complementary metal-oxide-semiconductor(CMOS) cameras. The optical emission from tissue was characterized during conventional irradiation using both blue and red-sensitive intensifiers to ensure adequate spectral coverage. Spectral characterization was performed using bandpass filters between the lens and sensor. Imaging of conventional proton fields (240 MeV, 10 nA) was performed at 100 Hz frame rate, while UHDR PBS proton delivery (250 MeV, 99 nA) was recorded at 1 kHz frame rate. Dependence of optical emission yield on proton energy was studied using an optical tissue-mimicking plastic phantom and a range shifter. Finally, we demonstrated fast beam tracking capability of fast camera towardsin vivomonitoring of FLASH PT.Main results. Under conventional treatment dose rates optical emission was imaged with single spot resolution. Spot profiles were found to agree with the treatment planning system calculation within >90% for all spectral bands and spot intensity was found to vary with spectral filtration. The resultant polychromatic emission presented a maximum intensity at 650 nm and decreasing signal at lower wavelengths, which is consistent with expected attenuation patterns of high fat and muscle tissue. For UHDR beam imaging, optical yield increased with higher proton energy. Imaging at 1 kHz allowed continuous monitoring of delivery during porcine tissue irradiation, with clear identification of individual dwell positions. The number of dwell positions matched the treatment plan in total and per row showing adequate temporal capability of iCMOS imaging.Significance. For the first time, this study characterizes optical emission from tissue during PT and demonstrates our capability of fast optical tracking of pencil proton beam on the tissue anatomy in both conventional and UHDR setting. Similar to the Cherenkov imaging in radiotherapy, this imaging modality could enable a seamless, independent validation of PT treatments.


Asunto(s)
Terapia de Protones , Animales , Porcinos , Terapia de Protones/métodos , Protones , Estudios Retrospectivos , Diagnóstico por Imagen , Fantasmas de Imagen
18.
J Biomed Opt ; 29(1): 016004, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38235320

RESUMEN

Significance: Fluorescence guidance is used clinically by surgeons to visualize anatomical and/or physiological phenomena in the surgical field that are difficult or impossible to detect by the naked eye. Such phenomena include tissue perfusion or molecular phenotypic information about the disease being resected. Conventional fluorescence-guided surgery relies on long, microsecond scale laser pulses to excite fluorescent probes. However, this technique only provides two-dimensional information; crucial depth information, such as the location of malignancy below the tissue surface, is not provided. Aim: We developed a depth sensing imaging technique using light detection and ranging (LiDAR) time-of-flight (TOF) technology to sense the depth of target tissue while overcoming the influence of tissue optical properties and fluorescent probe concentration. Approach: The technology is based on a large-format (512×512 pixel), binary, gated, single-photon avalanche diode (SPAD) sensor with an 18 ps time-gate step, synchronized with a picosecond pulsed laser. The fast response of the sensor was developed and tested for its ability to quantify fluorescent inclusions at depth and optical properties in tissue-like phantoms through analytical model fitting of the fast temporal remission data. Results: After calibration and algorithmic extraction of the data, the SPAD LiDAR technique allowed for sub-mm resolution depth sensing of fluorescent inclusions embedded in tissue-like phantoms, up to a maximum of 5 mm in depth. The approach provides robust depth sensing even in the presence of variable tissue optical properties and separates the effects of fluorescence depth from absorption and scattering variations. Conclusions: LiDAR TOF fluorescence imaging using an SPAD camera provides both fluorescence intensity images and the temporal profile of fluorescence, which can be used to determine the depth at which the signal is emitted over a wide field of view. The proposed tool enables fluorescence imaging at a higher depth in tissue and with higher spatial precision than standard, steady-state fluorescence imaging tools, such as intensity-based near-infrared fluorescence imaging, optical coherence tomography, Raman spectroscopy, or confocal microscopy. Integration of this technique into a standard surgical tool could enable rapid, more accurate estimation of resection boundaries, thereby improving the surgeon's efficacy and efficiency, and ultimately improving patient outcomes.


Asunto(s)
Neoplasias , Humanos , Neoplasias/diagnóstico por imagen , Fantasmas de Imagen , Imagen Óptica , Espectrometría Raman/métodos , Colorantes Fluorescentes
19.
Med Phys ; 51(7): 5109-5118, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38493501

RESUMEN

BACKGROUND: FLASH radiotherapy based on ultra-high dose rate (UHDR) is actively being studied by the radiotherapy community. Dedicated UHDR electron devices are currently a mainstay for FLASH studies. PURPOSE: To present the first Monte Carlo (MC) electron beam model for the UHDR capable Mobetron (FLASH-IQ) as a dose calculation and treatment planning platform for preclinical research and FLASH-radiotherapy (RT) clinical trials. METHODS: The initial beamline geometry of the Mobetron was provided by the manufacturer, with the first-principal implementation realized in the Geant4-based GAMOS MC toolkit. The geometry and electron source characteristics, such as energy spectrum and beamline parameters, were tuned to match the central-axis percentage depth dose (PDD) and lateral profiles for the pristine beam measured during machine commissioning. The thickness of the small foil in secondary scatter affected the beam model dominantly and was fine tuned to achieve the best agreement with commissioning data. Validation of the MC beam modeling was performed by comparing the calculated PDDs and profiles with EBT-XD radiochromic film measurements for various combinations of applicators and inserts. RESULTS: The nominal 9 MeV electron FLASH beams were best represented by a Gaussian energy spectrum with mean energy of 9.9 MeV and variance (σ) of 0.2 MeV. Good agreement between the MC beam model and commissioning data were demonstrated with maximal discrepancy < 3% for PDDs and profiles. Hundred percent gamma pass rate was achieved for all PDDs and profiles with the criteria of 2 mm/3%. With the criteria of 2 mm/2%, maximum, minimum and mean gamma pass rates were (100.0%, 93.8%, 98.7%) for PDDs and (100.0%, 96.7%, 99.4%) for profiles, respectively. CONCLUSIONS: A validated MC beam model for the UHDR capable Mobetron is presented for the first time. The MC model can be utilized for direct dose calculation or to generate beam modeling input required for treatment planning systems for FLASH-RT planning. The beam model presented in this work should facilitate translational and clinical FLASH-RT for trials conducted on the Mobetron FLASH-IQ platform.


Asunto(s)
Electrones , Método de Montecarlo , Aceleradores de Partículas , Dosificación Radioterapéutica , Electrones/uso terapéutico , Planificación de la Radioterapia Asistida por Computador/métodos , Dosis de Radiación
20.
Med Phys ; 51(8): 5738-5745, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38762909

RESUMEN

BACKGROUND: Ultra-high-dose-rate (UHDR) electron beams have been commonly utilized in FLASH studies and the translation of FLASH Radiotherapy (RT) to the clinic. The EDGE diode detector has potential use for UHDR dosimetry albeit with a beam energy dependency observed. PURPOSE: The purpose is to present the electron beam response for an EDGE detector in dependence on beam energy, to characterize the EDGE detector's response under UHDR conditions, and to validate correction factors derived from the first detailed Monte Carlo model of the EDGE diode against measurements, particularly under UHDR conditions. METHODS: Percentage depth doses (PDDs) for the UHDR Mobetron were measured with both EDGE detectors and films. A detailed Monte Carlo (MC) model of the EDGE detector has been configured according to the blueprint provided by the manufacturer under an NDA agreement. Water/silicon dose ratios of EDGE detector for a series of mono-energetic electron beams have been calculated. The dependence of the water/silicon dose ratio on depth for a FLASH relevant electron beam was also studied. An analytical approach for the correction of PDD measured with EDGE detectors was established. RESULTS: Water/silicon dose ratio decreased with decreasing electron beam energy. For the Mobetron 9 MeV UHDR electron beam, the ratio decreased from 1.09 to 1.03 in the build-up region, maintained in range of 0.98-1.02 at the fall-off region and raised to a plateau in value of 1.08 at the tail. By applying the corrections, good agreement between the PDDs measured by the EDGE detector and those measured with film was achieved. CONCLUSIONS: Electron beam response of an UHDR capable EDGE detector was derived from first principles utilizing a sophisticated MC model. An analytical approach was validated for the PDDs of UHDR electron beams. The results demonstrated the capability of EDGE detector in measuring PDDs of UHDR electron beams.


Asunto(s)
Electrones , Método de Montecarlo , Radiometría/instrumentación , Dosímetros de Radiación , Dosis de Radiación