Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Biomech Eng ; 141(10)2019 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-31116368

RESUMEN

Atrial fibrillation (AF) is the most common irregular heartbeat among the world's population and is a major contributor to cardiogenic embolisms and acute ischemic stroke (AIS). However, the role AF flow plays in the trajectory paths of cardiogenic emboli has not been experimentally investigated. A physiological simulation system was designed to analyze the trajectory patterns of bovine embolus analogs (EAs) (n = 720) through four patient-specific models, under three flow conditions: steady flow, normal pulsatile flow, and AF pulsatile flow. It was seen that EA trajectory paths were proportional to the percentage flowrate split of 25-31% along the branching vessels. Overall, AF flow conditions increased trajectories through the left- (LCCA) and right (RCCA)-common carotid artery by 25% with respect to normal pulsatile flow. There was no statistical difference in the distribution of clot trajectories when the clot was released from the right, left, or anterior positions. Significantly, more EAs traveled through the brachiocephalic trunk (BCT) than through the LCCA or the left subclavian. Yet of the EAs that traveled through the common carotid arteries, there was a greater affiliation toward the LCCA compared to the RCCA (p < 0.05).

2.
Neuroradiology ; 56(12): 1063-8, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25274137

RESUMEN

INTRODUCTION: This study aims to investigate diagnostic sensitivity and reliability for the detection of middle cerebral artery occlusion (MCAO) on non-contrast-enhanced computed tomography (NECT) by visual assessment (VA), Hounsfield unit (HU) measurement, calculation of the Hounsfield unit/hematocrit (HU/Hct) ratio, and combination of visual assessment and attenuation measurement (VA + HU). METHODS: NECT of 18 patients with angiographically proven MCAO and 18 patients without MCAO were reviewed by two blinded observers. Visual assessment of presence or absence of a hyperdense sign was followed by HU measurement of both middle cerebral arteries (MCA). Sensitivity, specificity, positive predictive value, and negative predictive value were calculated for VA, HU measurement, HU/Hct ratio, and VA + HU measurement. Receiver operating characteristic curve analysis (ROC) was performed to determine the optimal cut-off values for MCAO using attenuation measurements or HU/Hct ratio. RESULTS: Diagnostic sensitivity/specificity was 63%/91% for VA, 56%/88% for attenuation measurement, 68 %/81 % for HU/Hct ratio, and 75%/78% for VA + HU. ROC curve analysis revealed cut-off values of >42.5 HU for attenuation measurements and >1.12 HU/Hct for HU/Hct ratio. CONCLUSION: Combination of visual assessment with additional attenuation measurement with a cut-off value of 42.5 HU is recommended for most sensitive and reliable detection of MCAO on NECT.


Asunto(s)
Infarto de la Arteria Cerebral Media/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Anciano , Medios de Contraste , Femenino , Humanos , Masculino , Variaciones Dependientes del Observador , Estudios Retrospectivos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/estadística & datos numéricos
3.
Radiologe ; 54(1): 9-18, 2014 Jan.
Artículo en Alemán | MEDLINE | ID: mdl-24449280

RESUMEN

BACKGROUND: Radiological information technology (IT) is nowadays one of many components of an integrated hospital IT structure. OBJECTIVE: This review article is concerned with the challenges of a comprehensive and complete integration of all documented information and communication of all medical disciplines in a hospital in the electronic patient records. Special attention is paid to the role of radiology and the interface between radiological and clinical systems. PERSPECTIVES: The utilization of the documented data paying special attention to the requirements of data protection is a core aim for the further development of electronic patient records in the University Hospital Hamburg-Eppendorf in the coming years.


Asunto(s)
Seguridad Computacional , Registros Electrónicos de Salud/organización & administración , Registros de Salud Personal , Sistemas de Comunicación en Hospital/organización & administración , Servicio de Radiología en Hospital/organización & administración , Sistemas de Información Radiológica/organización & administración , Radiología/organización & administración , Control de Formularios y Registros/organización & administración , Alemania , Modelos Organizacionales , Integración de Sistemas
4.
J Neurooncol ; 112(2): 217-22, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23344787

RESUMEN

The most frequent primary brain tumors, anaplastic astrocytomas (AA) and glioblastomas (GBM): tend to invasion of the surrounding brain. Histopathological studies found malignant cells in macroscopically unsuspicious brain parenchyma remote from the primary tumor, even affecting the contralateral hemisphere. In early stages, diffuse interneural infiltration with changes of the apparent diffusion coefficient (ADC) and fractional anisotropy (FA) is suspected. The purpose of this study was to investigate the value of DTI as a possible instrument of depicting evidence of tumor invasion into the corpus callosum (CC). Preoperatively, 31 patients with high-grade brain tumors (8 AA and 23 GBM) were examined by MRI at 3 T, applying a high-resolution diffusion tensor imaging (DTI) sequence. ADC- and FA-values were analyzed in the tumor-associated area of the CC as identified by fiber tracking, and were compared to matched healthy controls. In (MR-)morphologically normal appearing CC the ADC values were elevated in the tumor patients (n = 22; 0.978 × 10(-3) mm²/s) compared to matched controls (0.917 × 10(-3) mm²/s, p < 0.05), and the corresponding relative FA was reduced (rFA: 88 %, p < 0.01). The effect was pronounced in case of affection of the CC visible on MRI (n = 9; 0.978 × 10(-3) mm²/s, p < 0.05; rFA: 72 %, p < 0.01). Changes in diffusivity and anisotropy in the CC can be interpreted as an indicator of tumor spread into the contralateral hemisphere not visible on conventional MRI.


Asunto(s)
Neoplasias Encefálicas/patología , Cuerpo Calloso/patología , Imagen de Difusión por Resonancia Magnética , Imagen de Difusión Tensora , Glioma/patología , Adulto , Anciano , Anisotropía , Neoplasias Encefálicas/mortalidad , Neoplasias Encefálicas/cirugía , Estudios de Casos y Controles , Cuerpo Calloso/cirugía , Detección Precoz del Cáncer , Femenino , Estudios de Seguimiento , Glioma/mortalidad , Glioma/cirugía , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Pronóstico , Tasa de Supervivencia , Adulto Joven
5.
Neuroradiology ; 55(2): 171-8, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23007858

RESUMEN

INTRODUCTION: To compare intra- and inter-observer reliability of aneurysm measurements obtained by a 3D computer-aided technique with standard manual aneurysm measurements in different imaging modalities. METHODS: A total of 21 patients with 29 cerebral aneurysms were studied. All patients underwent digital subtraction angiography (DSA), contrast-enhanced (CE-MRA) and time-of-flight magnetic resonance angiography (TOF-MRA). Aneurysm neck and depth diameters were manually measured by two observers in each modality. Additionally, semi-automatic computer-aided diameter measurements were performed using 3D vessel surface models derived from CE- (CE-com) and TOF-MRA (TOF-com) datasets. Bland-Altman analysis (BA) and intra-class correlation coefficient (ICC) were used to evaluate intra- and inter-observer agreement. RESULTS: BA revealed the narrowest relative limits of intra- and inter-observer agreement for aneurysm neck and depth diameters obtained by TOF-com (ranging between ±5.3 % and ±28.3 %) and CE-com (ranging between ±23.3 % and ±38.1 %). Direct measurements in DSA, TOF-MRA and CE-MRA showed considerably wider limits of agreement. The highest ICCs were observed for TOF-com and CE-com (ICC values, 0.92 or higher for intra- as well as inter-observer reliability). CONCLUSION: Computer-aided aneurysm measurement in 3D offers improved intra- and inter-observer reliability and a reproducible parameter extraction, which may be used in clinical routine and as objective surrogate end-points in clinical trials.


Asunto(s)
Algoritmos , Angiografía Cerebral/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Aneurisma Intracraneal/diagnóstico , Inteligencia Artificial , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
ScientificWorldJournal ; 2013: 248072, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24453817

RESUMEN

BACKGROUND: Although CSF cytology and MRI are standard methods to diagnose neoplastic meningitis (NM), this complication of neoplastic disease remains difficult to detect. We therefore reevaluated the sensitivity of gadolinium (GD)-enhanced MRI and cerebrospinal-fluid (CSF)-cytology and the relevance of tumor type and CSF cell count. METHODS: We retrospectively identified 111 cases of NM diagnosed in our CSF laboratory since 1990 with complete documentation of both MRI and CSF cytology. 37 had haematological and 74 solid neoplasms. CSF cell counts were increased in 74 and normal in 37 patients. RESULTS: In hematological neoplasms, MRI was positive in 49% and CSF cytology in 97%. In solid tumors, the sensitivity of MRI was 80% and of cytology 78%. With normal CSF cell counts, MRI was positive in 59% (50% hematological, 72% solid malignancies) and CSF cytology in 76% (92% in hematological, 68% in solid neoplasms). In cases of elevated cell counts, the sensitivity of MRI was 72% (50% for hematological, 83% for solid malignancies) and of CSF cytology 91% (100% for haematological and 85% for solid neoplasms). 91% of cytologically positive cases were diagnosed at first and another 7% at second lumbar puncture. Routine protein analyses had a low sensitivity in detecting NM. CONCLUSIONS: The high overall sensitivity of MRI was only confirmed for NM from solid tumors and for elevated CSF cell counts. With normal cell counts and haematological neoplasms, CSF-cytology was superior to MRI. None of the analysed routine CSF proteins had an acceptable sensitivity and specificity in detecting leptomeningeal disease.


Asunto(s)
Neoplasias Encefálicas/líquido cefalorraquídeo , Neoplasias Encefálicas/diagnóstico por imagen , Imagen por Resonancia Magnética , Meningitis/líquido cefalorraquídeo , Meningitis/diagnóstico por imagen , Recuento de Células , Femenino , Humanos , Masculino , Radiografía , Estudios Retrospectivos
7.
AJNR Am J Neuroradiol ; 41(7): 1232-1237, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32586965

RESUMEN

BACKGROUND AND PURPOSE: The Woven EndoBridge (WEB) device is an established technique for the treatment of intracranial aneurysms. Occasionally, persistent opacification inside the WEB lumen can be observed at follow-up (previously described as Bicêtre Occlusion Scale Score 1). We evaluated potential risk factors of this phenomenon, hypothesizing that initial deviation of the WEB device from the aneurysm axis, size of the aneurysmal neck surface, or inappropriate WEB sizing correlates with Bicêtre Occlusion Scale Score 1 findings. MATERIALS AND METHODS: We systematically reviewed all patients treated with the WEB device between February 2014 and December 2018 in our neurointerventional center. Patients with midterm follow-up DSA available were considered for aneurysm evaluation applying the Bicêtre Occlusion Scale Score. WEB angle deviation from the aneurysm axis, neck widths, and WEB sizes were collected. RESULTS: We included 65 patients with 67 intracranial aneurysms. Eleven of 67 (16.4%) intracranial aneurysms showed the Bicêtre Occlusion Scale Score 1 phenomenon at follow-up. Anterior-posterior projections of WEB axis deviation (angles measured in degrees) were significantly different between the Bicêtre Occlusion Scale Score 1 cohort (median ± interquartile range, 17 ± 17) and all other Bicêtre Occlusion Scale Scores (median ± interquartile range, 7 ± 11; P = .023), whereas in lateral projections, no significant difference was observed (median ± interquartile range, 10 ± 10 versus 8 ± 9; P = .169). Neck or aneurysm recurrence, but not the Bicêtre Occlusion Scale Score 1 phenomenon, occurred significantly more often in patients with inappropriate WEB sizing compared with appropriate WEB sizing (median ± interquartile range, 1 ± 1.3 versus 0 ± 0; P < .001/P = .664). CONCLUSIONS: The Bicêtre Occlusion Scale Score 1 phenomenon is associated with an initial deviation of the WEB device from the aneurysm axis but does not correlate with aneurysmal neck surface measurements or WEB sizing.


Asunto(s)
Prótesis Vascular , Aneurisma Intracraneal/terapia , Adulto , Anciano , Progresión de la Enfermedad , Embolización Terapéutica/instrumentación , Embolización Terapéutica/métodos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
8.
AJNR Am J Neuroradiol ; 41(4): 658-662, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32115421

RESUMEN

BACKGROUND AND PURPOSE: Flow diversion for the posterior circulation remains a promising treatment option for selected posterior circulation aneurysms. The Flow-Redirection Intraluminal Device (FRED) system has not been previously assessed in a large cohort of patients with posterior circulation aneurysms. The purpose of the present study was to assess safety and efficacy of FRED in this location. MATERIALS AND METHODS: Consecutive patients with posterior circulation aneurysms treated at 8 centers participating in the European FRED study (EuFRED) between April 2012 and January 2019 were retrospectively reviewed. Complication and radiographic and functional outcomes were evaluated. RESULTS: Eighty-four patients (median age, 54 years) with 84 posterior circulation aneurysms were treated with the FRED. A total of 25 aneurysms (29.8%) had previously ruptured, even though most aneurysms were diagnosed incidentally (45.2%). The intradural vertebral artery was the most common location (50%), and saccular, the most common morphology (40.5%). The median size was 7 mm. There were 8 (9.5%) symptomatic thromboembolic and no hemorrhagic complications. Thromboembolic complications occurred mostly (90.9%) in nonsaccular aneurysms. On last follow-up at a median of 24 months, 78.2% of aneurysms were completely occluded. Functional outcome at a median of 27 months was favorable in 94% of patients. All mortalities occurred in patients with acute subarachnoid hemorrhage and its sequelae. CONCLUSIONS: The largest cohort of posterior circulation aneurysms treated with the FRED to date demonstrated favorable safety and efficacy profiles of the device for this indication. Treatment in the setting of acute subarachnoid hemorrhage was strongly related to mortality, regardless of whether procedural complications occurred.


Asunto(s)
Embolización Terapéutica/instrumentación , Procedimientos Endovasculares/instrumentación , Aneurisma Intracraneal/terapia , Stents/efectos adversos , Adulto , Anciano , Estudios de Cohortes , Embolización Terapéutica/efectos adversos , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Sistema de Registros , Estudios Retrospectivos , Resultado del Tratamiento
9.
Minim Invasive Neurosurg ; 52(2): 89-92, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19452417

RESUMEN

INTRODUCTION: We report two cases of coil migration after endovascular treatment of pseudoaneurysm of the internal carotid artery within the sphenoid sinus with coils and noncovered stents. CASE REPORTS: Two patients underwent sphenoid sinus exposure for pituitary adenoma and chronic infection, respectively. As a complication pseudoaneurysms of the internal carotid artery within the sphenoid sinus developed. One patient was treated with stent and coils, the second with coils alone. Both patients experienced coil migration after 9 and 26 months, respectively, with the necessity for further treatment. Imaging was performed using flat detector computed tomography (FD-CT). Literature review revealed two additional cases of coil migration and four patients with the same treatment in stable condition. CONCLUSION: Pseudoaneurysms of the internal carotid artery are a special entity and the environment of the aneurysm within the sphenoid sinus may change over a long time. Coil embolization may lead to the late onset complication of coil migration with the possible risk of acute epistaxis. As a consequence, these patients need a careful and prolonged follow up. FD-CT is an appropriate technique to visualize the implanted coils and if present the migration of coil material.


Asunto(s)
Traumatismos de las Arterias Carótidas/cirugía , Arteria Carótida Interna/cirugía , Embolización Terapéutica/efectos adversos , Migración de Cuerpo Extraño/etiología , Complicaciones Posoperatorias/etiología , Seno Esfenoidal/cirugía , Adenoma/cirugía , Adulto , Traumatismos de las Arterias Carótidas/etiología , Traumatismos de las Arterias Carótidas/patología , Arteria Carótida Interna/patología , Embolización Terapéutica/instrumentación , Embolización Terapéutica/métodos , Femenino , Estudios de Seguimiento , Migración de Cuerpo Extraño/patología , Migración de Cuerpo Extraño/fisiopatología , Humanos , Masculino , Procedimientos Neuroquirúrgicos/efectos adversos , Procedimientos Neuroquirúrgicos/instrumentación , Procedimientos Neuroquirúrgicos/métodos , Neoplasias Hipofisarias/cirugía , Cuidados Posoperatorios/normas , Complicaciones Posoperatorias/patología , Complicaciones Posoperatorias/fisiopatología , Prótesis e Implantes/efectos adversos , Seno Esfenoidal/anatomía & histología , Seno Esfenoidal/patología , Sinusitis del Esfenoides/cirugía
10.
AJNR Am J Neuroradiol ; 39(5): 869-874, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29567657

RESUMEN

BACKGROUND AND PURPOSE: Angiographic occlusion and retreatment of coiled aneurysms are commonly used as surrogate end points in clinical trials. We aimed to evaluate the influence of aneurysm, patient, and rater characteristics on the confidence of visual evaluation of aneurysm coiling and retreatment decisions. MATERIALS AND METHODS: Twenty-six participants of the Advanced Course in Endovascular Interventional Neuroradiology of the European Society of Neuroradiology were asked to evaluate digital subtraction angiography examinations of patients who had undergone endovascular coiling, by determining the grade of aneurysm occlusion, the change between immediate postprocedural and follow-up angiograms, their level of confidence, the technical difficulty of retreatment, and the best therapeutic approach. The experience, knowledge, and skills of each participant were assessed. The influence of rater and case characteristics on indicated confidence in diagnostic ratings and retreatment recommendations was analyzed. RESULTS: Interrater reliability was moderate regarding the assessment of aneurysm occlusion grade (intraclass correlation coefficient = 0.581) and substantial regarding change (intraclass correlation coefficient = 0.776). Overall confidence in the diagnostic rating was high (median, "very certain"). Confidence was statistically significantly higher in cases that were generally rated as "worse." The odds of recommending retreatment were significantly higher in cases that were generally rated with higher mean confidence. CONCLUSIONS: Although overall confidence in the diagnostic rating was high, our study confirms the suboptimal interrater reliability of visual assessment of aneurysm occlusion as well as retreatment recommendations, rendering both questionable as primary outcome measures. Besides recurrence status, recommendation of retreatment is significantly influenced by patient age, aneurysm neck width, and characteristics of the therapist.


Asunto(s)
Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal/terapia , Resultado del Tratamiento , Adulto , Anciano , Embolización Terapéutica/instrumentación , Embolización Terapéutica/métodos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Reproducibilidad de los Resultados , Retratamiento
11.
AJNR Am J Neuroradiol ; 39(5): 841-847, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29545252

RESUMEN

BACKGROUND AND PURPOSE: Endoluminal reconstruction with flow-diverting stents represents a widely accepted technique for the treatment of complex intracranial aneurysms. This European registry study analyzed the initial experience of 15 neurovascular centers with the Flow-Redirection Intraluminal Device (FRED) system. MATERIALS AND METHODS: Consecutive patients with intracranial aneurysms treated with the FRED between February 2012 and March 2015 were retrospectively reviewed. Complications and adverse events, transient and permanent morbidity, mortality, and occlusion rates were evaluated. RESULTS: During the defined study period, 579 aneurysms in 531 patients (median age, 54 years; range, 13-86 years) were treated with the FRED. Seven percent of patients were treated in the acute phase (≤3 days) of aneurysm rupture. The median aneurysm size was 7.6 mm (range, 1-36.6 mm), and the median neck size 4.5 mm (range, 1-30 mm). Angiographic follow-up of >3 months was available for 516 (89.1%) aneurysms. There was progressive occlusion witnessed with time, with complete occlusion in 18 (20%) aneurysms followed for up to 90 ± 14 days, 141 (82.5%) for 180 ± 20 days, 116 (91.3%) for 1 year ± 24 days, and 122 (95.3%) aneurysms followed for >1 year. Transient and permanent morbidity occurred in 3.2% and 0.8% of procedures, respectively. The overall mortality rate was 1.5%. CONCLUSIONS: This retrospective study in real-world patients demonstrated the safety and efficacy of the FRED for the treatment of intracranial aneurysms. In most cases, treatment with a single FRED resulted in complete angiographic occlusion at 1 year.


Asunto(s)
Procedimientos Endovasculares/instrumentación , Aneurisma Intracraneal/cirugía , Stents , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Angiografía Cerebral , Procedimientos Endovasculares/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
12.
AJNR Am J Neuroradiol ; 38(6): 1151-1155, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28450432

RESUMEN

BACKGROUND AND PURPOSE: Flow disruption with the Woven EndoBridge (WEB) device is an innovative technique for the endovascular treatment of wide-neck bifurcation aneurysms. The initial version of the device (WEB Double-Layer) was evaluated in the WEB Clinical Assessment of IntraSaccular Aneurysm Therapy (WEBCAST) study, whereas the French Observatory study evaluated both WEB Double-Layer and Single-Layer versions of the device. WEBCAST 2 was designed to evaluate the WEB Single-Layer with Enhanced Visualization. MATERIALS AND METHODS: Patients with wide-neck bifurcation aneurysms for which WEB treatment was possible were included. Clinical data including adverse events and clinical status at 1 month and 1 year were collected and analyzed. A core laboratory evaluated anatomic results at 1 year following the procedure. RESULTS: Ten European neurointerventional centers included 55 patients (38 women; 27-77 years of age; mean, 54.4 ± 10.0 years) with 55 aneurysms. Aneurysm locations were the middle cerebral artery in 25 aneurysms (45.5%), the anterior communicating artery in 16 (29.1%), the basilar artery in 9 (16.4%), and the internal carotid artery terminus in 5 (9.1%). Procedural morbidity and mortality at 1 month were, respectively, 1.8% (1/55 patients) and 0.0% (0/55 patients). Morbidity and mortality at 1 year were, respectively, 3.9% (2/51 patients) and 2.0% (1/51 patients). At 1 year, complete occlusion was observed in 27/50 aneurysms (54.0%); neck remnant, in 13/50 (26.0%); and aneurysm remnant, in 10/50 (20.0%) (adequate occlusion in 40/50, 80.0%). CONCLUSIONS: WEBCAST 2 confirms the high safety and efficacy of WEB aneurysm treatment demonstrated in the WEBCAST and French Observatory studies.


Asunto(s)
Procedimientos Endovasculares/instrumentación , Aneurisma Intracraneal/terapia , Adulto , Anciano , Procedimientos Endovasculares/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
13.
AJNR Am J Neuroradiol ; 27(7): 1508-13, 2006 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16908570

RESUMEN

We describe a patient who experienced a fatal ipsilateral basal ganglia hemorrhage within an hour after carotid angioplasty and stent placement. In the few similar cases published there were no prodromata, but hyperacute onset of severe neurologic deterioration corresponding to intracerebral hemorrhage (ICH). Our findings suggest that besides the delayed ICH that is associated with hyperperfusion syndrome (HPS), a second type of hyperacute and usually fatal ICH exists that resembles hypertensive hemorrhage.


Asunto(s)
Hemorragia de los Ganglios Basales/etiología , Estenosis Carotídea/terapia , Hipertensión Intracraneal/etiología , Stents , Anciano , Angioplastia de Balón/efectos adversos , Diagnóstico Diferencial , Resultado Fatal , Femenino , Estudios de Seguimiento , Cefalea/etiología , Humanos , Náusea y Vómito Posoperatorios/etiología , Stents/efectos adversos , Hemorragia Subaracnoidea/etiología , Síndrome
14.
Rofo ; 178(9): 862-71, 2006 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-16953478

RESUMEN

PURPOSE: To assess a new flat panel volume computed tomography (FP-VCT) with very high isotropic spatial resolution as well as high Z-axis coverage. MATERIALS AND METHODS: The prototype of an FP-VCT scanner with a detector cell size of 0.2 mm was used for numerous phantom studies, specimen examinations, and animal research projects. RESULTS: The high spatial resolution of the new system can be used to accurately determine solid tumor volume, thus allowing for earlier assessment of the therapeutic response. In animal experimentation, whole-body perfusion mapping of mice is feasible. The high spatial resolution also improves the classification of coronary artery atherosclerotic plaques in the isolated post mortem human heart. With the depiction of intramyocardial segments of the coronary arteries, investigations of myocardial collateral circulation are feasible. In skeletal applications, an accurate analysis of the smallest bony structures, e. g., petrous bone and dental preparations, can be successfully performed, as well as investigations of repetitive studies of fracture healing and the treatment of osteoporosis. CONCLUSION: The introduction of FP-VCT opens up new applications for CT, including the field of molecular imaging, which are highly attractive for future clinical applications. Present limitations include limited temporal resolution and necessitate further improvement of the system.


Asunto(s)
Tomografía Computarizada por Rayos X , Animales , Huesos/diagnóstico por imagen , Corazón/diagnóstico por imagen , Ratones , Microrradiografía/instrumentación , Ratas , Sarcoma Experimental/diagnóstico por imagen , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos
15.
AJNR Am J Neuroradiol ; 37(1): 120-4, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26294648

RESUMEN

BACKGROUND AND PURPOSE: As part of a multicenter cooperation (Aneurysm-Like Synthetic bodies for Testing Endovascular devices in 3D Reality) with focus on implementation of additive manufacturing in neuroradiologic practice, we systematically assessed the technical feasibility and accuracy of several additive manufacturing techniques. We evaluated the method of fused deposition modeling for the production of aneurysm models replicating patient-specific anatomy. MATERIALS AND METHODS: 3D rotational angiographic data from 10 aneurysms were processed to obtain volumetric models suitable for fused deposition modeling. A hollow aneurysm model with connectors for silicone tubes was fabricated by using acrylonitrile butadiene styrene. Support material was dissolved, and surfaces were finished by using NanoSeal. The resulting models were filled with iodinated contrast media. 3D rotational angiography of the models was acquired, and aneurysm geometry was compared with the original patient data. RESULTS: Reproduction of hollow aneurysm models was technically feasible in 8 of 10 cases, with aneurysm sizes ranging from 41 to 2928 mm(3) (aneurysm diameter, 3-19 mm). A high level of anatomic accuracy was observed, with a mean Dice index of 93.6% ± 2.4%. Obstructions were encountered in vessel segments of <1 mm. CONCLUSIONS: Fused deposition modeling is a promising technique, which allows rapid and precise replication of cerebral aneurysms. The porosity of the models can be overcome by surface finishing. Models produced with fused deposition modeling may serve as educational and research tools and could be used to individualize treatment planning.


Asunto(s)
Angiografía Cerebral , Imagenología Tridimensional , Aneurisma Intracraneal/diagnóstico por imagen , Modelos Cardiovasculares , Impresión Tridimensional , Tomografía Computarizada por Rayos X , Medios de Contraste , Procedimientos Endovasculares/instrumentación , Seguridad de Equipos , Estudios de Factibilidad , Humanos , Imagenología Tridimensional/métodos , Aneurisma Intracraneal/terapia
16.
Rofo ; 187(8): 691-6, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26019049

RESUMEN

PURPOSE: To evaluate the incidence of additional thoracic pathologic findings (TPF) detected on scout views and corresponding bolus tracking slices (SVBT) for computed tomographic cerebral angiography (CTCA) and to test the reliability and accuracy of these findings. MATERIALS AND METHODS: The study collective included 505 consecutive patients who underwent multidetector CTCA. Appendant SVBT of all patients were reviewed for any pathologic findings and patient medical reports were analyzed, if any medical treatment was initiated for the detected pathologic findings. In 18 patients thoracic CT scans were performed in the same session. These were additionally reviewed by two blinded observers to test for intra- and interobserver reliability as well as for accuracy of detecting thoracic pathologies on SVBT. RESULTS: TPF were detected in 165 (33%) SVBT. The five most common pathologic findings were: pleural effusion, 12%; pneumonia, 8%; atelectasis/dystelecatsis, 6%; pericardial effusion, 2% and elevated diaphragm, 1%. For 48 % of these findings medical treatment was initiated. SVBT showed a sensitivity of 53%, a specificity of 99%, a positive predictive value of 89%, a negative predictive value of 94% and accuracy of 94% for the detection of TPF. The intraobserver reliability was very good and the interobserver reliability showed moderate agreement. CONCLUSION: SVBT for CTCA should be reviewed with care by radiologists, since additional TPF can affect patient management. Nevertheless, despite a high specificity of SVBT for detecting TPF, an only moderate sensitivity has to be taken into account. KEY POINTS: Thoracic pathologies are frequently found on scout views for cerebral CTA. Reviewing additional bolus trigger slices will improve diagnostic sensitivity. Despite high specificity, scout views and trigger slices offer a moderate sensitivity. Evaluation of scout views and trigger slices can result in medical treatment.


Asunto(s)
Angiografía Cerebral/métodos , Interpretación de Imagen Asistida por Computador/métodos , Hallazgos Incidentales , Tomografía Computarizada Multidetector/métodos , Enfermedades Torácicas/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Estudios Retrospectivos , Sensibilidad y Especificidad
17.
AJNR Am J Neuroradiol ; 36(9): 1589-98, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26185325

RESUMEN

BACKGROUND AND PURPOSE: Gadobenate dimeglumine (MultiHance) has higher r1 relaxivity than gadoterate meglumine (Dotarem) which may permit the use of lower doses for MR imaging applications. Our aim was to compare 0.1- and 0.05-mmol/kg body weight gadobenate with 0.1-mmol/kg body weight gadoterate for MR imaging assessment of brain tumors. MATERIALS AND METHODS: We performed crossover, intraindividual comparison of 0.1-mmol/kg gadobenate with 0.1-mmol/kg gadoterate (Arm 1) and 0.05-mmol/kg gadobenate with 0.1-mmol/kg gadoterate (Arm 2). Adult patients with suspected or known brain tumors were randomized to Arm 1 (70 patients) or Arm 2 (107 patients) and underwent 2 identical examinations at 1.5 T. The agents were injected in randomized-sequence order, and the 2 examinations were separated by 2-14 days. MR imaging scanners, imaging sequences (T1-weighted spin-echo and T1-weighted high-resolution gradient-echo), and acquisition timing were identical for the 2 examinations. Three blinded readers evaluated images for diagnostic information (degree of definition of lesion extent, lesion border delineation, visualization of lesion internal morphology, contrast enhancement) and quantitatively for percentage lesion enhancement and lesion-to-background ratio. Safety assessments were performed. RESULTS: In Arm 1, a highly significant superiority (P < .002) of 0.1-mmol/kg gadobenate was demonstrated by all readers for all end points. In Arm 2, no significant differences (P > .1) were observed for any reader and any end point, with the exception of percentage enhancement for reader 2 (P < .05) in favor of 0.05-mmol/kg gadobenate. Study agent-related adverse events were reported by 2/169 (1.2%) patients after gadobenate and by 5/175 (2.9%) patients after gadoterate. CONCLUSIONS: Significantly superior morphologic information and contrast enhancement are demonstrated on brain MR imaging with 0.1-mmol/kg gadobenate compared with 0.1-mmol/kg gadoterate. No meaningful differences were recorded between 0.05-mmol/kg gadobenate and 0.1-mmol/kg gadoterate.


Asunto(s)
Neoplasias Encefálicas/patología , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Medios de Contraste , Estudios Cruzados , Femenino , Humanos , Masculino , Meglumina/análogos & derivados , Persona de Mediana Edad , Compuestos Organometálicos
18.
Rofo ; 185(9): 824-9, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23857073

RESUMEN

PURPOSE: To evaluate a novel algorithm for correcting beam hardening artifacts caused by metal implants in computed tomography performed on a C-arm angiography system equipped with a flat panel (FP-CT). MATERIALS AND METHODS: 16 datasets of cerebral FP-CT acquisitions after coil embolization of brain aneurysms in the context of acute subarachnoid hemorrhage have been reconstructed by applying a soft tissue kernel with and without a novel reconstruction filter for metal artifact correction. Image reading was performed in multiplanar reformations (MPR) in average mode on a dedicated radiological workplace in comparison to the preinterventional native multisection CT (MS-CT) scan serving as the anatomic gold standard. Two independent radiologists performed image scoring following a defined scale in direct comparison of the image data with and without artifact correction. For statistical analysis, a random intercept model was calculated. RESULTS: The inter-rater agreement was very high (ICC = 86.3 %). The soft tissue image quality and visualization of the CSF spaces at the level of the implants was substantially improved. The additional metal artifact correction algorithm did not induce impairment of the subjective image quality in any other brain regions. CONCLUSION: Adding metal artifact correction to FP-CT in an acute postinterventional setting helps to visualize the close vicinity of the aneurysm at a generally consistent image quality.


Asunto(s)
Algoritmos , Artefactos , Angiografía Cerebral/métodos , Embolización Terapéutica/métodos , Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Metales , Prótesis e Implantes , Hemorragia Subaracnoidea/diagnóstico por imagen , Hemorragia Subaracnoidea/terapia , Tomografía Computarizada por Rayos X/métodos , Enfermedad Aguda , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector/métodos , Variaciones Dependientes del Observador , Sensibilidad y Especificidad
19.
Rofo ; 185(1): 60-5, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23059700

RESUMEN

PURPOSE: The physical background of diffusion phenomena in intracranial cysts is unclear in some cases. To evaluate a potential dependency of proton diffusion on the concentration of proteins in cystic lesions we investigated the correlation of diffusion weighted imaging (DWI) and magnetization transfer ratio imaging (MTR) in intracranial cystic pathologies in vivo and in vitro with protein solutions. MATERIALS AND METHODS: 21 patients (14 male/7 female) with intracranial cystic lesions underwent preoperative MRI (1.5T) including MTR and DWI sequences. For comparison a series of samples with declining concentration of albumin was investigated in vitro with a 7T animal scanner. RESULTS: In the patients examination mean ADC values were 1.93×10-3mm2/sec and mean MTR values were 0.2. Mean ADC value of the albumin solutions was 0.22× 0-3mm2/sec and mean MTR was 0.12. ADC and MTR values showed a strong negative correlation in the patients (Spearman's rank correlation rs=-0.80, p<0.01) and a very strong negative correlation in the in vitro examinations (rs=-1.0, p<0.01). CONCLUSION: The strong negative correlation of ADC and MTR values suggest a strong influence of proteins on proton diffusion in intracranial cysts. The phenomena can be explained by macromolecules that bind nearby protons in their vicinity.


Asunto(s)
Artefactos , Encefalopatías/metabolismo , Encefalopatías/patología , Quistes/química , Quistes/patología , Proteínas del Tejido Nervioso/química , Adulto , Anciano , Quistes Aracnoideos , Difusión , Femenino , Humanos , Masculino , Persona de Mediana Edad , Protones , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
20.
Rofo ; 185(8): 741-8, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23900941

RESUMEN

OBJECTIVES: To intraindividually evaluate the potential of 4th generation iterative reconstruction (IR) on brain CT with regard to subjective and objective image quality. METHODS: 31 consecutive raw data sets of clinical routine native sequential brain CT scans were reconstructed with IR level 0 (= filtered back projection), 1, 3 and 4; 3 different brain filter kernels (smooth/standard/sharp) were applied respectively. Five independent radiologists with different levels of experience performed subjective image rating. Detailed ROI analysis of image contrast and noise was performed. Statistical analysis was carried out by applying a random intercept model. RESULTS: Subjective scores for the smooth and the standard kernels were best at low IR levels, but both, in particular the smooth kernel, scored inferior with an increasing IR level. The sharp kernel scored lowest at IR 0, while the scores substantially increased at high IR levels, reaching significantly best scores at IR 4. Objective measurements revealed an overall increase in contrast-to-noise ratio at higher IR levels, which was highest when applying the soft filter kernel. The absolute grey-white contrast decreased with an increasing IR level and was highest when applying the sharp filter kernel. All subjective effects were independent of the raters' experience and the patients' age and sex. CONCLUSION: Different combinations of IR level and filter kernel substantially influence subjective and objective image quality of brain CT.


Asunto(s)
Encefalopatías/diagnóstico por imagen , Encéfalo/diagnóstico por imagen , Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Adulto , Anciano , Anciano de 80 o más Años , Artefactos , Enfermedad Cerebrovascular de los Ganglios Basales/diagnóstico por imagen , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/secundario , Corteza Cerebral/diagnóstico por imagen , Infarto Cerebral/diagnóstico por imagen , Femenino , Humanos , Aumento de la Imagen/normas , Procesamiento de Imagen Asistido por Computador/normas , Hemorragias Intracraneales/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Radiografía , Sistemas de Información Radiológica , Valores de Referencia , Sensibilidad y Especificidad , Base del Cráneo/diagnóstico por imagen , Accidente Cerebrovascular/diagnóstico por imagen , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA