Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Microbes Infect ; 5(5): 379-85, 2003 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-12737993

RESUMEN

Ebola virus (EBOV) is a member of the family Filoviridae and is classified as a biosafety level 4 virus. This classification makes the preparation of antigen and performance of diagnostic assays time-consuming and complicated. The objective of this study was to evaluate the value of EBOV immunoassays based on recombinant nucleoprotein (r-NP) and recombinant VP35 (r-VP35) using large serum panels of African origin and from primates. Furthermore, we investigated whether the results obtained with EBOV r-VP35 enzyme-linked immunosorbent assay (ELISA) could improve on the findings obtained with the EBOV r-NP ELISA. The full-length EBOV NP and VP35 of the EBOV subtype Zaire were expressed as histidine-tagged recombinant proteins in the baculovirus expression system. The antigenic reactivity and specificity of these recombinant proteins were determined by Western blotting and ELISA using EBOV specific monoclonal antibodies. The results obtained with the r-NP and r-VP35 ELISAs were compared with the results obtained in an indirect immunofluorescence assay based on native EBOV subtype Zaire. EBOV specific monoclonal antibodies reacted specifically with the respective proteins in both Western blot and ELISA. Five hundred and twenty six samples from humans and primates were tested with r-NP and r-VP35 ELISAs. Monkey serum samples positive for EBOV subtype Reston and Zaire were both positive in the EBOV r-NP ELISA, whereas only the EBOV Zaire infected monkeys were positive in the r-VP35 ELISA. The sensitivity and specificity values of the EBOV recombinants' ELISAs compared to those of the immunofluorescence assay were 92% and 99% for r-NP and 44% and 100% for r-VP35. r-NP ELISA proved to be a sensitive and specific assay for EBOV diagnosis and for epidemiological studies for both EBOV subtypes Reston and Zaire. The use of r-VP35 in an ELISA format has no additional value for EBOV serodiagnosis.


Asunto(s)
Anticuerpos Antivirales/sangre , Baculoviridae/metabolismo , Ebolavirus/inmunología , Nucleoproteínas/inmunología , Proteínas del Núcleo Viral/inmunología , Adolescente , Adulto , Animales , Baculoviridae/genética , Western Blotting , Ebolavirus/genética , Ebolavirus/metabolismo , Ensayo de Inmunoadsorción Enzimática , Técnica del Anticuerpo Fluorescente Indirecta , Fiebre Hemorrágica Ebola/inmunología , Fiebre Hemorrágica Ebola/veterinaria , Fiebre Hemorrágica Ebola/virología , Humanos , Macaca , Persona de Mediana Edad , Enfermedades de los Monos/inmunología , Enfermedades de los Monos/virología , Proteínas de la Nucleocápside , Nucleoproteínas/genética , Nucleoproteínas/metabolismo , Proteínas Recombinantes/inmunología , Sensibilidad y Especificidad , Proteínas del Núcleo Viral/genética , Proteínas del Núcleo Viral/metabolismo
2.
J Clin Microbiol ; 41(9): 4154-9, 2003 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-12958240

RESUMEN

Accurate and timely diagnosis of dengue virus (DEN) infections is essential for the differential diagnosis of patients with febrile illness and hemorrhagic fever. In the present study, the diagnostic value of a newly developed immune-complex dissociated nonstructural-1 (NS-1) antigen dot blot immunoassay (DBI) was compared to a commercially available DEN antigen detection kit (denKEY Blue kit; Globio Co., Beverly, Mass.) and a reverse transcription-PCR (RT-PCR) kit. Serial serum or plasma samples (n = 181) obtained from 55 acute DEN-infected patients were used. In samples obtained from 32 of these 55 DEN-infected patients, viral RNA could be detected by RT-PCR. DEN antigen was detected in only 10 of these 55 patient samples by using the denKEY kit. When these samples were treated with acid to release the immune-complex-associated NS-1 antigen for detection by DBI, 43 of these 55 patients were found to be positive for DEN NS-1 antigen. In nondissociated samples, 22 of these patients were found to be positive by the DBI. In the presence of DEN-specific immunoglobulin M antibodies, both viral RNA and DEN (NS-1) antigen could be detected. The number of positive samples identified by RT-PCR and DBI from these patients with primary DEN infections varied between 28 and 78%. In secondary DEN infections, the number of samples that tested positive by the DBI after immune-complex dissociation (DIS-DBI) was 25% higher than the number of samples that tested positive by RT-PCR and was 35% higher than that determined by nondissociated antigen (NDIS-DBI) detection. We conclude that the denKEY kit has limited diagnostic value for acute DEN infections compared to the RT-PCR and the NDIS-DBI and DIS-DBI methods. We clearly demonstrate that in secondary DEN infections the dissociation of NS-1 immune complexes is essential for early diagnosis of DEN infections.


Asunto(s)
Complejo Antígeno-Anticuerpo/sangre , Antígenos Virales/sangre , Virus del Dengue/inmunología , Dengue/diagnóstico , Proteínas no Estructurales Virales/sangre , Enfermedad Aguda , Humanos , Inmunoensayo , Inmunoglobulina M , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA