Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
J Cardiovasc Magn Reson ; 19(1): 36, 2017 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-28343449

RESUMEN

BACKGROUND: Heart failure related to cardiac siderosis remains a major cause of death in transfusion dependent anaemias. Replacement fibrosis has been reported as causative of heart failure in siderotic cardiomyopathy in historical reports, but these findings do not accord with the reversible nature of siderotic heart failure achievable with intensive iron chelation. METHODS: Ten whole human hearts (9 beta-thalassemia major, 1 sideroblastic anaemia) were examined for iron loading and fibrosis (replacement and interstitial). Five had died from heart failure, 4 had cardiac transplantation for heart failure, and 1 had no heart failure (death from a stroke). Heart samples iron content was measured using atomic emission spectroscopy. Interstitial fibrosis was quantified by computer using picrosirius red (PSR) staining and expressed as collagen volume fraction (CVF) with normal value for left ventricle <3%. RESULTS: The 9 hearts affected by heart failure had severe iron loading with very low T2* of 5.0 ± 2.0 ms (iron concentration 8.5 ± 7.0 mg/g dw) and diffuse granular myocardial iron deposition. In none of the 10 hearts was significant macroscopic replacement fibrosis present. In only 2 hearts was interstitial fibrosis present, but with low CVF: in one patient with no cardiac siderosis (death by stroke, CVF 5.9%) and in a heart failure patient (CVF 2%). In the remaining 8 patients, no interstitial fibrosis was seen despite all having severe cardiac siderosis and heart failure (CVF 1.86% ±0.87%). CONCLUSION: Replacement cardiac fibrosis was not seen in the 9 post-mortem hearts from patients with severe cardiac siderosis and heart failure leading to death or transplantation, which contrasts markedly to historical reports. Minor interstitial fibrosis was also unusual and very limited in extent. These findings accord with the potential for reversibility of heart failure seen in iron overload cardiomyopathy. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT00520559.


Asunto(s)
Transfusión Sanguínea , Cardiomiopatías/metabolismo , Cardiomiopatías/patología , Insuficiencia Cardíaca/metabolismo , Insuficiencia Cardíaca/patología , Hemosiderosis/metabolismo , Hemosiderosis/patología , Hierro/análisis , Miocardio/química , Miocardio/patología , Talasemia beta/terapia , Adolescente , Adulto , Autopsia , Compuestos Azo/química , Transfusión Sanguínea/mortalidad , Cardiomiopatías/mortalidad , Cardiomiopatías/cirugía , Causas de Muerte , Niño , Colágeno/análisis , Colorantes/química , Femenino , Fibrosis , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/cirugía , Trasplante de Corazón , Hemosiderosis/mortalidad , Hemosiderosis/cirugía , Humanos , Masculino , Persona de Mediana Edad , Índice de Severidad de la Enfermedad , Espectrofotometría Atómica , Coloración y Etiquetado/métodos , Adulto Joven , Talasemia beta/sangre , Talasemia beta/diagnóstico , Talasemia beta/mortalidad
2.
Circulation ; 128(15): 1623-33, 2013 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-23965488

RESUMEN

BACKGROUND: Cardiovascular magnetic resonance is the gold-standard technique for the assessment of ventricular function. Although left ventricular volumes and ejection fraction are strong predictors of outcome in dilated cardiomyopathy (DCM), there are limited data regarding the prognostic significance of right ventricular (RV) systolic dysfunction (RVSD). We investigated whether cardiovascular magnetic resonance assessment of RV function has prognostic value in DCM. METHODS AND RESULTS: We prospectively studied 250 consecutive DCM patients with the use of cardiovascular magnetic resonance. RVSD, defined by RV ejection fraction≤45%, was present in 86 (34%) patients. During a median follow-up period of 6.8 years, there were 52 deaths, and 7 patients underwent cardiac transplantation. The primary end point of all-cause mortality or cardiac transplantation was reached by 42 of 86 patients with RVSD and 17 of 164 patients without RVSD (49% versus 10%; hazard ratio, 5.90; 95% confidence interval [CI], 3.35-10.37; P<0.001). On multivariable analysis, RVSD remained a significant independent predictor of the primary end point (hazard ratio, 3.90; 95% CI, 2.16-7.04; P<0.001), as well as secondary outcomes of cardiovascular mortality or cardiac transplantation (hazard ratio, 3.35; 95% CI, 1.76-6.39; P<0.001), and heart failure death, heart failure hospitalization, or cardiac transplantation (hazard ratio, 2.70; 95% CI, 1.32-5.51; P=0.006). Assessment of RVSD improved risk stratification for all-cause mortality or cardiac transplantation (net reclassification improvement, 0.31; 95% CI 0.10-0.53; P=0.001). CONCLUSIONS: RVSD is a powerful, independent predictor of transplant-free survival and adverse heart failure outcomes in DCM. Cardiovascular magnetic resonance assessment of RV function is important in the evaluation and risk stratification of DCM patients.


Asunto(s)
Cardiomiopatía Dilatada/mortalidad , Cardiomiopatía Dilatada/patología , Disfunción Ventricular Derecha/mortalidad , Disfunción Ventricular Derecha/patología , Adulto , Anciano , Cardiomiopatía Dilatada/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Prevalencia , Pronóstico , Estudios Prospectivos , Factores de Riesgo , Volumen Sistólico/fisiología , Disfunción Ventricular Derecha/fisiopatología , Función Ventricular Derecha/fisiología
3.
Magn Reson Med ; 72(1): 260-8, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23963595

RESUMEN

PURPOSE: To investigate the feasibility of improving MRI R2* mapping by filtering the images before curve-fitting. METHODS: Pixel-by-pixel curve-fitting for the quantification of MRI relaxometry remains a challenge for low signal-to-noise ratio images. By computing the weighted mean of spatially adjacent pixels, the low-pass Gaussian (LPG) filter can suppress the noise but at the expense of blurring. By assigning high weights to pixels with similar neighborhood patches, the nonlocal means (NLM) algorithm can reduce noise while retaining intrinsic signals, however, its potential has not been explored in pixel-by-pixel MRI relaxometry, and in this study, we aimed to investigate the impact of the LPG and the NLM filtering on decay signals and MRI R2* mapping. These two filtering methods were compared on both simulated and in vivo data. RESULTS: Both LPG and NLM algorithms produces R2* maps with decreased root-mean-square-errors. The LPG filter blurs edges of R2* maps while the NLM algorithm preserves details well. The NLM consistently yields R2* mapping with smaller errors than the LPG filtering in all cases. CONCLUSION: Pixel-by-pixel fitting can skew MRI relaxometry. The NLM outperforms the conventional LPG filter and has the potential to provide more accurate pixel-by-pixel MRI relaxometry for improved tissue characterization.


Asunto(s)
Algoritmos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Sobrecarga de Hierro/patología , Hígado/patología , Imagen por Resonancia Magnética/métodos , Simulación por Computador , Humanos , Fantasmas de Imagen , Estudios Retrospectivos , Relación Señal-Ruido
4.
J Cardiovasc Magn Reson ; 16: 80, 2014 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-25270330

RESUMEN

BACKGROUND: MRI assessment of cardiac iron is particularly important for assessing transfusion-dependent anaemia patients. However, comparing the iron distribution from histology or bulk samples to MRI is not ideal. Non-destructive, high-resolution imaging of post-mortem samples offers the ability to examine iron distributions across large samples at resolutions closer to those used in MRI. The aim of this ex vivo case study was to compare synchrotron X-ray fluorescence microscopy (XFM) elemental iron maps with magnetic resonance transverse relaxation rate maps of cardiac tissue samples from an iron-loaded patient. METHODS: Two 5 mm thick slices of formalin fixed cardiac tissue from a Diamond Blackfan anaemia patient were imaged in a 1.5 T MR scanner. R2 and R2* transverse relaxation rate maps were generated for both slices using RF pulse recalled spin echo and gradient echo acquisition sequences. The tissue samples were then imaged at the Australian Synchrotron on the X-ray Fluorescence Microscopy beamline using a focussed incident X-ray beam of 18.74 keV and the Maia 384 detector. The event data were analyzed to produce elemental iron maps (uncalibrated) at 25 to 60 microns image resolution. RESULTS: The R2 and R2* maps and profiles for both samples showed very similar macro-scale spatial patterns compared to the XFM iron distribution. Iron appeared to preferentially load into the lateral epicardium wall and there was a strong gradient of decreasing iron, R2 and R2* from the epicardium to the endocardium in the lateral wall of the left ventricle and to a lesser extent in the septum. On co-registered images XFM iron was more strongly correlated to R2* (r = 0.86) than R2 (r = 0.79). There was a strong linear relationship between R2* and R2 (r = 0.87). CONCLUSIONS: The close qualitative and quantitative agreement between the synchrotron XFM iron maps and MR relaxometry maps indicates that iron is a significant determinant of R2 and R2* in these ex vivo samples. The R2 and R2* maps of human heart tissue give information on the spatial distribution of tissue iron deposits.


Asunto(s)
Anemia de Diamond-Blackfan/metabolismo , Hierro/análisis , Imagen por Resonancia Magnética , Microscopía Fluorescente/métodos , Miocardio/química , Sincrotrones , Anemia de Diamond-Blackfan/diagnóstico , Anemia de Diamond-Blackfan/terapia , Autopsia , Resultado Fatal , Humanos , Masculino , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Adulto Joven
5.
J Cardiovasc Magn Reson ; 16: 40, 2014 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-24915987

RESUMEN

BACKGROUND: There is a need to standardise non-invasive measurements of liver iron concentrations (LIC) so clear inferences can be drawn about body iron levels that are associated with hepatic and extra-hepatic complications of iron overload. Since the first demonstration of an inverse relationship between biopsy LIC and liver magnetic resonance (MR) using a proof-of-concept T2* sequence, MR technology has advanced dramatically with a shorter minimum echo-time, closer inter-echo spacing and constant repetition time. These important advances allow more accurate calculation of liver T2* especially in patients with high LIC. METHODS: Here, we used an optimised liver T2* sequence calibrated against 50 liver biopsy samples on 25 patients with transfusional haemosiderosis using ordinary least squares linear regression, and assessed the method reproducibility in 96 scans over an LIC range up to 42 mg/g dry weight (dw) using Bland-Altman plots. Using mixed model linear regression we compared the new T2*-LIC with R2-LIC (Ferriscan) on 92 scans in 54 patients with transfusional haemosiderosis and examined method agreement using Bland-Altman approach. RESULTS: Strong linear correlation between ln(T2*) and ln(LIC) led to the calibration equation LIC = 31.94(T2*)-1.014. This yielded LIC values approximately 2.2 times higher than the proof-of-concept T2* method. Comparing this new T2*-LIC with the R2-LIC (Ferriscan) technique in 92 scans, we observed a close relationship between the two methods for values up to 10 mg/g dw, however the method agreement was poor. CONCLUSIONS: New calibration of T2* against liver biopsy estimates LIC in a reproducible way, correcting the proof-of-concept calibration by 2.2 times. Due to poor agreement, both methods should be used separately to diagnose or rule out liver iron overload in patients with increased ferritin.


Asunto(s)
Hemosiderosis/diagnóstico , Hierro/análisis , Hígado/química , Hígado/patología , Imagen por Resonancia Magnética/normas , Algoritmos , Benzoatos/uso terapéutico , Biomarcadores/análisis , Biopsia , Calibración , Deferasirox , Hemosiderosis/tratamiento farmacológico , Hemosiderosis/etiología , Hemosiderosis/metabolismo , Hemosiderosis/patología , Humanos , Interpretación de Imagen Asistida por Computador , Quelantes del Hierro/uso terapéutico , Análisis de los Mínimos Cuadrados , Modelos Lineales , Hígado/efectos de los fármacos , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Reacción a la Transfusión , Triazoles/uso terapéutico
6.
J Cardiovasc Magn Reson ; 16: 62, 2014 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-25158620

RESUMEN

BACKGROUND: The assessment of myocardial iron using T2* cardiovascular magnetic resonance (CMR) has been validated and calibrated, and is in clinical use. However, there is very limited data assessing the relaxation parameters T1 and T2 for measurement of human myocardial iron. METHODS: Twelve hearts were examined from transfusion-dependent patients: 11 with end-stage heart failure, either following death (n=7) or cardiac transplantation (n=4), and 1 heart from a patient who died from a stroke with no cardiac iron loading. Ex-vivo R1 and R2 measurements (R1=1/T1 and R2=1/T2) at 1.5 Tesla were compared with myocardial iron concentration measured using inductively coupled plasma atomic emission spectroscopy. RESULTS: From a single myocardial slice in formalin which was repeatedly examined, a modest decrease in T2 was observed with time, from mean (± SD) 23.7 ± 0.93 ms at baseline (13 days after death and formalin fixation) to 18.5 ± 1.41 ms at day 566 (p<0.001). Raw T2 values were therefore adjusted to correct for this fall over time. Myocardial R2 was correlated with iron concentration [Fe] (R2 0.566, p<0.001), but the correlation was stronger between LnR2 and Ln[Fe] (R2 0.790, p<0.001). The relation was [Fe] = 5081•(T2)-2.22 between T2 (ms) and myocardial iron (mg/g dry weight). Analysis of T1 proved challenging with a dichotomous distribution of T1, with very short T1 (mean 72.3 ± 25.8 ms) that was independent of iron concentration in all hearts stored in formalin for greater than 12 months. In the remaining hearts stored for <10 weeks prior to scanning, LnR1 and iron concentration were correlated but with marked scatter (R2 0.517, p<0.001). A linear relationship was present between T1 and T2 in the hearts stored for a short period (R2 0.657, p<0.001). CONCLUSION: Myocardial T2 correlates well with myocardial iron concentration, which raises the possibility that T2 may provide additive information to T2* for patients with myocardial siderosis. However, ex-vivo T1 measurements are less reliable due to the severe chemical effects of formalin on T1 shortening, and therefore T1 calibration may only be practical from in-vivo human studies.


Asunto(s)
Insuficiencia Cardíaca/diagnóstico , Hemosiderosis/diagnóstico , Hierro/metabolismo , Imagen por Resonancia Magnética/normas , Contracción Miocárdica , Miocardio/metabolismo , Función Ventricular Izquierda , Adolescente , Adulto , Biomarcadores/metabolismo , Calibración , Niño , Europa (Continente) , Femenino , Fijadores , Formaldehído , Insuficiencia Cardíaca/metabolismo , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/patología , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/cirugía , Trasplante de Corazón , Hemosiderosis/metabolismo , Hemosiderosis/mortalidad , Hemosiderosis/patología , Hemosiderosis/fisiopatología , Hemosiderosis/cirugía , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Miocardio/patología , Valor Predictivo de las Pruebas , Pronóstico , Espectrofotometría Atómica , Tailandia , Factores de Tiempo , Fijación del Tejido/métodos , Adulto Joven
7.
Haematologica ; 98(9): 1368-74, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23812939

RESUMEN

Accumulation of myocardial iron is the cause of heart failure and early death in most transfused thalassemia major patients. T2* cardiovascular magnetic resonance provides calibrated, reproducible measurements of myocardial iron. However, there are few data regarding myocardial iron loading and its relation to outcome across the world. A survey is reported of 3,095 patients in 27 worldwide centers using T2* cardiovascular magnetic resonance. Data on baseline T2* and numbers of patients with symptoms of heart failure at first scan (defined as symptoms and signs of heart failure with objective evidence of left ventricular dysfunction) were requested together with more detailed information about patients who subsequently developed heart failure or died. At first scan, 20.6% had severe myocardial iron (T2*≤ 10 ms), 22.8% had moderate myocardial iron (T2* 10-20 ms) and 56.6% of patients had no iron loading (T2*>20 ms). There was significant geographical variation in myocardial iron loading (24.8-52.6%; P<0.001). At first scan, 85 (2.9%) of 2,915 patients were reported to have heart failure (81.2% had T2* <10 ms; 98.8% had T2* <20 ms). During follow up, 108 (3.8%) of 2,830 patients developed new heart failure. Of these, T2* at first scan had been less than 10 ms in 96.3% and less than 20 ms in 100%. There were 35 (1.1%) cardiac deaths. Of these patients, myocardial T2* at first scan had been less than 10 ms in 85.7% and less than 20 ms in 97.1%. Therefore, in this worldwide cohort of thalassemia major patients, over 43% had moderate/severe myocardial iron loading with significant geographical differences, and myocardial T2* values less than 10 ms were strongly associated with heart failure and death.


Asunto(s)
Recolección de Datos/métodos , Internacionalidad , Imagen por Resonancia Cinemagnética , Talasemia beta/diagnóstico , Talasemia beta/epidemiología , Estudios de Cohortes , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/epidemiología , Humanos , Sobrecarga de Hierro/diagnóstico , Sobrecarga de Hierro/epidemiología , Imagen por Resonancia Cinemagnética/métodos
8.
J Magn Reson Imaging ; 37(2): 479-83, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22927335

RESUMEN

PURPOSE: To propose an automated truncation method for myocardial T2* measurement and evaluate this method on a large population of patients with iron loading in the heart and scanned at multiple magnetic resonance imaging (MRI) centers. MATERIALS AND METHODS: A total of 550 thalassemia patients were scanned at 20 international centers using a variety of MR scanners (Siemens, Philips, or GE). A single mid-ventricular short axis slice was imaged. All patient data were anonymized before the T2* were measured by expert observers using standard techniques. These same datasets were then retrospectively processed using the proposed automated truncation method by another independent observer and the resulting T2* measurements were compared with those of expert readings. RESULTS: The T2* measurements using the automated method showed good agreement with those measured by expert observers using standard techniques (P = 0.95) with a low coefficient of variation (1.6%). CONCLUSION: This study demonstrates feasibility and good reproducibility of a new automated truncation method for myocardial T2* measurement. This approach simplifies the overall analysis and can be easily incorporated into T2* analysis software to facilitate further development of a fully automated myocardial tissue iron quantification.


Asunto(s)
Algoritmos , Cardiomiopatías/patología , Interpretación de Imagen Asistida por Computador/métodos , Sobrecarga de Hierro/patología , Imagen por Resonancia Cinemagnética/métodos , Talasemia/patología , Cardiomiopatías/etiología , Estudios de Factibilidad , Femenino , Humanos , Aumento de la Imagen/métodos , Internacionalidad , Sobrecarga de Hierro/etiología , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Talasemia/complicaciones
9.
J Magn Reson Imaging ; 38(3): 588-93, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23371802

RESUMEN

PURPOSE: To compare myocardial T1 against T2 and T2* in patients with thalassemia major (TM) for myocardial iron characterization. MATERIALS AND METHODS: A total of 106 TM patients (29 ± 10 years; 58 males) were studied on a 1.5 Tesla scanner using dedicated T1, T2*, and T2 relaxometry sequences. A single mid-ventricular short axis slice was acquired within a breath-hold. RESULTS: In patients with myocardial iron overload (T2* < 20 ms; n = 52), there were linear correlations between T2 and T2* (r = 0.82; P = 0.0), and between T1 and T2* (r = 0.83; P = 0.0). In patients with no myocardial iron (n = 54), T2* values were scattered with no significant correlation against T2 or T1. For all patients (n = 106) there was a strong linear correlation (r = 0.93; P = 0.0) between myocardial T1 and T2. CONCLUSION: In patients with iron overload, myocardial T2 and T1 are correlated with T2*. In patients with low or normal myocardial iron concentration, other factors become dominant in affecting T2* values as shown by scattered T2* data. Myocardial T1 correlates linearly with T2 measurements in all patients suggesting that these two relaxation parameters avoid extrinsic magnetic field inhomogeneity effects and may potentially provide improved myocardial tissue characterization.


Asunto(s)
Cardiomiopatías/complicaciones , Cardiomiopatías/patología , Sobrecarga de Hierro/complicaciones , Sobrecarga de Hierro/patología , Imagen por Resonancia Magnética/métodos , Talasemia beta/complicaciones , Talasemia beta/patología , Femenino , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
10.
J Cardiovasc Magn Reson ; 15: 60, 2013 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-23870663

RESUMEN

The 16th Annual Scientific Sessions of the Society for Cardiovascular Magnetic Resonance (SCMR) took place in San Francisco, USA at the end of January 2013. With a faculty of experts from across the world, this congress provided a wealth of insight into cutting-edge research and technological development. This review article intends to provide a highlight of what represented the most significant advances in the field of cardiovascular magnetic resonance (CMR) during this year's meeting.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico , Imagen por Resonancia Magnética/métodos , Humanos
11.
J Cardiovasc Magn Reson ; 15: 24, 2013 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-23509881

RESUMEN

BACKGROUND: Chronically increased intestinal iron uptake in genetic hemochromatosis (HC) may cause organ failure. Whilst iron loading from blood transfusions may cause dilated cardiomyopathy in conditions such as thalassemia, the in-vivo prevalence of myocardial siderosis in HC is unclear, and its relation to left ventricular (LV) dysfunction is controversial. Most previous data on myocardial siderosis in HC has come from post-mortem studies. METHODS: Cardiovascular magnetic resonance (CMR) was performed at first presentation of 41 HC patients (58.9 ± 14.1 years) to measure myocardial iron and left ventricular (LV) ejection fraction (EF). RESULTS: In 31 patients (genetically confirmed HFE-HC), the HFE genotype was C282Y/C282Y (n = 30) and C282Y/H63D (n = 1). Patients with other genotypes (n = 10) were labeled genetically unconfirmed HC. Of the genetically confirmed HFE-HC patients, 6 (19%) had myocardial siderosis (T2* <20 ms). Of these, 5 (83%) had heart failure and reduced LVEF which was correlated to the severity of siderosis (R2 0.57, p = 0.049). Two patients had follow-up scans and both had marked improvements in T2* and LVEF following venesection. Myocardial siderosis was present in 6/18 (33%) of patients with presenting ferritin ≥ 1000 µg/L at diagnosis but in 0/13 (0%) patients with ferritin <1000 µg/L (p = 0.028). Overall however, the relation between myocardial siderosis and ferritin was weak (R2 0.20, p = 0.011). In the 10 genetically unconfirmed HC patients, 1 patient had mild myocardial siderosis but normal EF. Of all 31 patients, 4 had low LVEF from other identifiable causes without myocardial siderosis. CONCLUSION: Myocardial siderosis was present in 33% of newly presenting genetically confirmed HFE-HC patients with ferritin >1000 µg/L, and was the commonest cause of reduced LVEF. Heart failure due to myocardial siderosis was only found in these HFE-HC patients, and was reversible with venesection. Myocardial iron was normal in patients with other causes of LV dysfunction.


Asunto(s)
Cardiomiopatías/etiología , Hemocromatosis/complicaciones , Hemosiderosis/etiología , Miocardio/metabolismo , Disfunción Ventricular Izquierda/etiología , Función Ventricular Izquierda , Adulto , Anciano , Biomarcadores/sangre , Cardiomiopatías/sangre , Cardiomiopatías/diagnóstico , Cardiomiopatías/patología , Cardiomiopatías/fisiopatología , Cardiomiopatías/terapia , Ferritinas/sangre , Predisposición Genética a la Enfermedad , Insuficiencia Cardíaca/sangre , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/fisiopatología , Hemocromatosis/sangre , Hemocromatosis/diagnóstico , Hemocromatosis/genética , Hemocromatosis/terapia , Proteína de la Hemocromatosis , Hemosiderosis/sangre , Hemosiderosis/diagnóstico , Hemosiderosis/patología , Hemosiderosis/fisiopatología , Hemosiderosis/terapia , Antígenos de Histocompatibilidad Clase I/genética , Humanos , Modelos Lineales , Imagen por Resonancia Magnética , Proteínas de la Membrana/genética , Persona de Mediana Edad , Miocardio/patología , Fenotipo , Flebotomía , Estudios Prospectivos , Volumen Sistólico , Disfunción Ventricular Izquierda/sangre , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/patología , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/terapia
12.
J Cardiovasc Magn Reson ; 15: 76, 2013 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-24006874

RESUMEN

There were 90 articles published in the Journal of Cardiovascular Magnetic Resonance (JCMR) in 2012, which is an 8% increase in the number of articles since 2011. The quality of the submissions continues to increase. The editors are delighted to report that the 2011 JCMR Impact Factor (which is published in June 2012) has risen to 4.44, up from 3.72 for 2010 (as published in June 2011), a 20% increase. The 2011 impact factor means that the JCMR papers that were published in 2009 and 2010 were cited on average 4.44 times in 2011. The impact factor undergoes natural variation according to citation rates of papers in the 2 years following publication, and is significantly influenced by highly cited papers such as official reports. However, the progress of the journal's impact over the last 5 years has been impressive. Our acceptance rate is approximately 25%, and has been falling as the number of articles being submitted has been increasing. In accordance with Open-Access publishing, the JCMR articles go on-line as they are accepted with no collating of the articles into sections or special thematic issues. For this reason, the Editors have felt that it is useful once per calendar year to summarize the papers for the readership into broad areas of interest or theme, so that areas of interest can be reviewed in a single article in relation to each other and other recent JCMR articles. The papers are presented in broad themes and set in context with related literature and previously published JCMR papers to guide continuity of thought in the journal. We hope that you find the open-access system increases wider reading and citation of your papers, and that you will continue to send your quality manuscripts to JCMR for publication.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico , Imagen por Resonancia Magnética , Publicaciones Periódicas como Asunto , Animales , Bibliometría , Enfermedades Cardiovasculares/fisiopatología , Enfermedades Cardiovasculares/terapia , Políticas Editoriales , Humanos , Factor de Impacto de la Revista , Valor Predictivo de las Pruebas , Pronóstico
13.
Circulation ; 123(14): 1519-28, 2011 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-21444881

RESUMEN

BACKGROUND: Measurement of myocardial iron is key to the clinical management of patients at risk of siderotic cardiomyopathy. The cardiovascular magnetic resonance relaxation parameter R2* (assessed clinically via its reciprocal, T2*) measured in the ventricular septum is used to assess cardiac iron, but iron calibration and distribution data in humans are limited. METHODS AND RESULTS: Twelve human hearts were studied from transfusion-dependent patients after either death (heart failure, n=7; stroke, n=1) or transplantation for end-stage heart failure (n=4). After cardiovascular magnetic resonance R2* measurement, tissue iron concentration was measured in multiple samples of each heart with inductively coupled plasma atomic emission spectroscopy. Iron distribution throughout the heart showed no systematic variation between segments, but epicardial iron concentration was higher than in the endocardium. The mean ± SD global myocardial iron causing severe heart failure in 10 patients was 5.98 ± 2.42 mg/g dry weight (range, 3.19 to 9.50 mg/g), but in 1 outlier case of heart failure was 25.9 mg/g dry weight. Myocardial ln[R2*] was strongly linearly correlated with ln[Fe] (R²=0.910, P<0.001), leading to [Fe]=45.0×(T2*)⁻¹·²² for the clinical calibration equation with [Fe] in milligrams per gram dry weight and T2* in milliseconds. Midventricular septal iron concentration and R2* were both highly representative of mean global myocardial iron. CONCLUSIONS: These data detail the iron distribution throughout the heart in iron overload and provide calibration in humans for cardiovascular magnetic resonance R2* against myocardial iron concentration. The iron values are of considerable interest in terms of the level of cardiac iron associated with iron-related death and indicate that the heart is more sensitive to iron loading than the liver. The results also validate the current clinical practice of monitoring cardiac iron in vivo by cardiovascular magnetic resonance of the midseptum.


Asunto(s)
Hierro/metabolismo , Imagen por Resonancia Magnética/métodos , Miocardio/metabolismo , Miocardio/patología , Adolescente , Adulto , Cadáver , Niño , Femenino , Atrios Cardíacos/metabolismo , Atrios Cardíacos/patología , Válvulas Cardíacas/metabolismo , Válvulas Cardíacas/patología , Ventrículos Cardíacos/metabolismo , Ventrículos Cardíacos/patología , Humanos , Sobrecarga de Hierro/metabolismo , Masculino , Persona de Mediana Edad , Tabique Interventricular/metabolismo , Tabique Interventricular/patología , Adulto Joven
14.
J Cardiovasc Magn Reson ; 14: 78, 2012 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-23158097

RESUMEN

There were 83 articles published in the Journal of Cardiovascular Magnetic Resonance (JCMR) in 2011, which is an 11% increase in the number of articles since 2010. The quality of the submissions continues to increase. The editors had been delighted with the 2010 JCMR Impact Factor of 4.33, although this fell modestly to 3.72 for 2011. The impact factor undergoes natural variation according to citation rates of papers in the 2 years following publication, and is significantly influenced by highly cited papers such as official reports. However, we remain very pleased with the progress of the journal's impact over the last 5 years. Our acceptance rate is approximately 25%, and has been falling as the number of articles being submitted has been increasing. In accordance with Open-Access publishing, the JCMR articles go on-line as they are accepted with no collating of the articles into sections or special thematic issues. For this reason, the Editors feel it is useful to summarize the papers for the readership into broad areas of interest or theme, which we feel would be useful, so that areas of interest from the previous year can be reviewed in a single article in relation to each other and other recent JCMR articles. The papers are presented in broad themes and set in context with related literature and previously published JCMR papers to guide continuity of thought in the journal. We hope that you find the open-access system increases wider reading and citation of your papers, and that you will continue to send your quality manuscripts to JCMR for publication.


Asunto(s)
Investigación Biomédica , Enfermedades Cardiovasculares/diagnóstico , Imagen por Resonancia Magnética , Publicaciones Periódicas como Asunto , Animales , Bibliometría , Investigación Biomédica/estadística & datos numéricos , Políticas Editoriales , Humanos , Difusión de la Información , Factor de Impacto de la Revista , Imagen por Resonancia Magnética/estadística & datos numéricos , Publicaciones Periódicas como Asunto/estadística & datos numéricos , Valor Predictivo de las Pruebas , Pronóstico
15.
J Cardiovasc Magn Reson ; 14: 8, 2012 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-22277065

RESUMEN

BACKGROUND: Combination therapy with deferoxamine and oral deferiprone is superior to deferoxamine alone in removing cardiac iron and improving left ventricular ejection fraction (LVEF). The right ventricle (RV) is also affected by the toxic effects of iron and may cause additional cardiovascular perturbation. We assessed the effects of combination therapy on the RV in thalassaemia major (TM) using cardiovascular magnetic resonance (CMR). METHODS: We retrieved imaging data from 2 treatment trials and re-analyzed the data for the RV responses: Trial 1 was a randomized controlled trial (RCT) of 65 TM patients with mild-moderate cardiac siderosis receiving combination therapy or deferoxamine with placebo; Trial 2 was an open label longitudinal trial assessing combination therapy in 15 TM patients with severe iron loading. RESULTS: In the RCT, combination therapy with deferoxamine and deferiprone was superior to deferoxamine alone for improving RVEF (3.6 vs 0.7%, p = 0.02). The increase in RVEF was greater with lower baseline T2* 8-12 ms (4.7 vs 0.5%, p = 0.01) than with T2* 12-20 ms (2.2 vs 0.8%, p = 0.47). In patients with severe cardiac siderosis, substantial improvement in RVEF was seen with open-label combination therapy (10.5% ± 5.6%, p < 0.01). CONCLUSIONS: In the RCT of mild to moderate cardiac iron loading, combination treatment improved RV function significantly more than deferoxamine alone. Combination treatment also improved RV function in severe cardiac siderosis. Therefore adding deferiprone to deferoxamine has beneficial effects on both RV and LV function in TM patients with cardiac siderosis.


Asunto(s)
Deferoxamina/uso terapéutico , Hemosiderosis/tratamiento farmacológico , Quelantes del Hierro/uso terapéutico , Piridonas/uso terapéutico , Sideróforos/uso terapéutico , Disfunción Ventricular Derecha/tratamiento farmacológico , Función Ventricular Derecha/efectos de los fármacos , Talasemia beta/tratamiento farmacológico , Adulto , Análisis de Varianza , Distribución de Chi-Cuadrado , Deferiprona , Quimioterapia Combinada , Ecocardiografía Doppler , Femenino , Hemosiderosis/diagnóstico , Hemosiderosis/etiología , Hemosiderosis/fisiopatología , Humanos , Imagen por Resonancia Magnética , Masculino , Ensayos Clínicos Controlados Aleatorios como Asunto , Recuperación de la Función , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Volumen Sistólico/efectos de los fármacos , Terapéutica , Factores de Tiempo , Disfunción Ventricular Derecha/diagnóstico , Disfunción Ventricular Derecha/etiología , Disfunción Ventricular Derecha/fisiopatología , Talasemia beta/complicaciones , Talasemia beta/diagnóstico , Talasemia beta/fisiopatología
16.
J Cardiovasc Magn Reson ; 13: 8, 2011 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-21241474

RESUMEN

BACKGROUND: Heart failure remains a major cause of mortality in thalassaemia major. The possible role of cardiac fibrosis in thalassemia major in the genesis of heart failure is not clear. It is also unclear whether cardiac fibrosis might arise as a result of heart failure. METHODS: We studied 45 patients with thalassaemia major who had a wide range of current cardiac iron loading and included patients with prior and current heart failure. Myocardial iron was measured using T2* cardiovascular magnetic resonance (CMR), and following this, late gadolinium enhancement (LGE) was used to determine the presence of macroscopic myocardial fibrosis. RESULTS: The median myocardial T2* in all patients was 22.6 ms (range 5.3-58.8 ms). Fibrosis was detected in only one patient, whose myocardial T2* was 20.1 ms and left ventricular ejection fraction 57%. No fibrosis was identified in 5 patients with a history of heart failure with full recovery, in 3 patients with current left ventricular dysfunction undergoing treatment, or in 18 patients with myocardial iron loading with cardiacT2* < 20 ms at the time of scan. CONCLUSION: This study shows that macroscopic myocardial fibrosis is uncommon in thalassemia major across a broad spectrum of myocardial iron loading. Importantly, there was no macroscopic fibrosis in patients with current or prior heart failure, or in patients with myocardial iron loading without heart failure. Therefore if myocardial fibrosis indeed contributes to myocardial dysfunction in thalassemia, our data combined with the knowledge that the myocardial dysfunction of iron overload can be reversed, indicates that any such fibrosis would need to be both microscopic and reversible.


Asunto(s)
Medios de Contraste , Gadolinio DTPA , Insuficiencia Cardíaca/patología , Imagen por Resonancia Magnética , Miocardio/patología , Talasemia beta/complicaciones , Adolescente , Adulto , Inglaterra , Femenino , Fibrosis , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/metabolismo , Insuficiencia Cardíaca/fisiopatología , Humanos , Hierro/metabolismo , Masculino , Miocardio/metabolismo , Valor Predictivo de las Pruebas , Prevalencia , Volumen Sistólico , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/patología , Función Ventricular Izquierda , Adulto Joven , Talasemia beta/metabolismo , Talasemia beta/patología , Talasemia beta/fisiopatología
17.
J Cardiovasc Magn Reson ; 13: 21, 2011 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-21401929

RESUMEN

PURPOSE: To assess whether black blood T2* cardiovascular magnetic resonance is superior to conventional white blood imaging of cardiac iron in patients with thalassaemia major (TM). MATERIALS AND METHODS: We performed both conventional white blood and black blood T2* CMR sequences in 100 TM patients to determine intra and inter-observer variability and presence of artefacts. In 23 patients, 2 separate studies of both techniques were performed to assess interstudy reproducibility. RESULTS: Cardiac T2* values ranged from 4.5 to 43.8 ms. The mean T2* values were not different between black blood and white blood acquisitions (20.5 vs 21.6 ms, p=0.26). Compared with the conventional white blood diastolic acquisition, the coefficient of variance of the black blood CMR technique was superior for intra-observer reproducibility (1.47% vs 4.23%, p<0.001), inter-observer reproducibility (2.54% vs 4.50%, p<0.001) and inter-study reproducibility (4.07% vs 8.42%, p=0.001). Assessment of artefacts showed a superior score for black blood vs white blood scans (4.57 vs 4.25; p<0.001). CONCLUSIONS: Black blood T2* CMR has superior reproducibility and reduced imaging artefacts for the assessment of cardiac iron, in comparison with the conventional white blood technique, which make it the preferred technique for clinical practice.


Asunto(s)
Cardiopatías/diagnóstico , Hemosiderosis/diagnóstico , Hierro/metabolismo , Imagen por Resonancia Magnética/métodos , Miocardio/metabolismo , Reacción a la Transfusión , Talasemia beta/terapia , Adolescente , Adulto , Artefactos , Niño , Femenino , Cardiopatías/sangre , Cardiopatías/etiología , Hemosiderosis/sangre , Hemosiderosis/etiología , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Adulto Joven , Talasemia beta/sangre
18.
J Cardiovasc Magn Reson ; 13: 34, 2011 Jul 06.
Artículo en Inglés | MEDLINE | ID: mdl-21733147

RESUMEN

BACKGROUND: Thalassaemia major (TM) patients need regular blood transfusions that lead to accumulation of iron and death from heart failure. Deferiprone has been reported to be superior to deferoxamine for the removal of cardiac iron and improvement in left ventricular (LV) function but little is known of their relative effects on the right ventricle (RV), which is being increasingly recognised as an important prognostic factor in cardiomyopathy. Therefore data from a prospective randomised controlled trial (RCT) comparing these chelators was retrospectively analysed to assess the RV responses to these drugs. METHODS: In the RCT, 61 TM patients were randomised to receive either deferiprone or deferoxamine monotherapy, and CMR scans for T2* and cardiac function were obtained. Data were re-analysed for RV volumes and function at baseline, and after 6 and 12 months of treatment. RESULTS: From baseline to 12 months, deferiprone reduced RV end systolic volume (ESV) from 37.7 to 34.2 mL (p=0.008), whilst RV ejection fraction (EF) increased from 69.6 to 72.2% (p=0.001). This was associated with a 27% increase in T2* (p<0.001) and 3.1% increase in LVEF (p<0.001). By contrast, deferoxamine showed no change in RVESV (38.1 to 39.1 mL, p=0.38), or RVEF (70.0 to 69.9%, p=0.93) whereas the T2* increased by 13% (p<0.001), but with no change in LVEF (0.32%; p=0.66). Analysis of between drugs treatment effects, showed significant improvements favouring deferiprone with a mean effect on RVESV of -1.82 mL (p=0.014) and 1.16% for RVEF (p=0.009). Using regression analysis the improvement in RVEF at 12 months was shown to be greater in patients with lower baseline EF values (p<0.001), with a significant difference in RVEF of 3.5% favouring deferiprone over deferoxamine (p=0.012). CONCLUSION: In this retrospective analysis of a prospective RCT, deferiprone monotherapy was superior to deferoxamine for improvement in RVEF and end-systolic volume. This improvement in the RV volumes and function may contribute to the improved cardiac outcomes seen with deferiprone.


Asunto(s)
Cardiomiopatías/tratamiento farmacológico , Deferoxamina/uso terapéutico , Quelantes del Hierro/uso terapéutico , Sobrecarga de Hierro/tratamiento farmacológico , Miocardio/metabolismo , Piridonas/uso terapéutico , Sideróforos/uso terapéutico , Reacción a la Transfusión , Función Ventricular Derecha/efectos de los fármacos , Talasemia beta/terapia , Adulto , Análisis de Varianza , Cardiomiopatías/diagnóstico , Cardiomiopatías/etiología , Cardiomiopatías/metabolismo , Cardiomiopatías/fisiopatología , Deferiprona , Femenino , Grecia , Humanos , Sobrecarga de Hierro/diagnóstico , Sobrecarga de Hierro/etiología , Sobrecarga de Hierro/metabolismo , Sobrecarga de Hierro/fisiopatología , Italia , Imagen por Resonancia Magnética , Masculino , Estudios Multicéntricos como Asunto , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Retrospectivos , Volumen Sistólico/efectos de los fármacos , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda/efectos de los fármacos , Adulto Joven , Talasemia beta/sangre
19.
Eur Heart J ; 31(13): 1648-54, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20413399

RESUMEN

AIMS: Myocardial T2* cardiovascular magnetic resonance (CMR) provides a rapid and reproducible measure of cardiac iron loading and is being increasingly used worldwide for monitoring of transfusion-dependent thalassaemia patients. Although myocardial siderosis (T2* <20 ms) is associated with impaired left ventricular (LV) function, little is known of its relation with right ventricular (RV) function. The aim of this study was to investigate the relationship between cardiac T2* and RV function. METHODS AND RESULTS: A retrospective analysis of 319 patients with beta-thalassaemia major presenting for their first CMR scan was performed (45.1% male, mean age 25.6 years). In patients with normal myocardial T2* (>20 ms), the RV ejection fraction (EF) was within the normal range in 98% of patients. When myocardial T2* was <20 ms, there was a progressive and significant decline in RV EF. There was a linear relationship between RV and LV EF. CONCLUSION: Myocardial iron deposition is strongly associated with RV dysfunction, which mirrors the decrease in LV function seen with worsening cardiac iron loading. Right ventricular dysfunction may play a significant role in heart failure associated with myocardial siderosis.


Asunto(s)
Cardiomiopatías/diagnóstico , Disfunción Ventricular Derecha/diagnóstico , Talasemia beta/complicaciones , Adulto , Cardiomiopatías/fisiopatología , Femenino , Insuficiencia Cardíaca/etiología , Ventrículos Cardíacos , Hemosiderosis/complicaciones , Hemosiderosis/fisiopatología , Humanos , Hierro/metabolismo , Angiografía por Resonancia Magnética , Masculino , Estudios Retrospectivos , Volumen Sistólico , Disfunción Ventricular Derecha/fisiopatología , Talasemia beta/fisiopatología
20.
Cardiol Res ; 12(3): 161-168, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34046110

RESUMEN

BACKGROUND: The ambulatory arterial stiffness index (AASI) obtained during ambulatory blood pressure monitoring (ABPM) has been cited as an independent predictor of major adverse cardiovascular events (MACEs) including cardiovascular death, stroke and worsening chronic kidney disease (CKD) among mixed-sex adult populations. This study aimed to determine the relationship between AASI and MACE and its predictive precision in women. METHODS: This work follows the guidelines of the STROBE initiative for cohort studies. This was a retrospective single-center observational study of adult women (aged 18 - 75 years), who underwent 24-h ABPM for the diagnosis of hypertension or its control. The primary endpoint was a composite MACE of cardiovascular death, acute limb ischemia, stroke, acute coronary syndrome (ACS), or progression to stage V CKD. RESULTS: A total of 219 women aged 57.4 ± 13.3 years were followed up for a median (interquartile range (IQR)) of 25.5 (18.3 - 31.3) months. Overall, 16 (7.3%) patients suffered one or more MACE events. AASI was significantly higher in patients with known coronary artery disease (CAD), diabetes mellitus, peripheral vascular disease (PVD), heart failure, previous stroke, or transient ischemic attack (TIA). AASI was a significant predictor of MACE (area under the curve: 0.78; P < 0.001) with an optimal cut-off of ≥ 0.56. On Kaplan-Meier analysis AASI ≥ 0.56 was significantly associated with MACE (log-rank test, P < 0.001). The only independent predictors of MACE on Cox proportional hazard analysis were diabetes mellitus, low high-density lipoprotein (HDL) levels, cumulative AASI values, or AASI ≥ 0.56. CONCLUSIONS: An AASI of ≥ 0.56 is an independent predictor of MACE in women. A further validation study in a larger cohort of women is recommended.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA