Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
BMC Infect Dis ; 15: 152, 2015 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-25885702

RESUMEN

BACKGROUND: Healthcare-associated infections (HAIs) are a frequent complication associated with hospitalization of infants in neonatal intensive care units (NICUs). The aim of this study was to evaluate and describe the results of surveillance of HAIs in a III level NICU in Naples, Italy during 2006-2010. METHODS: The surveillance covered 1,699 neonates of all birth weight (BW) classes with >2 days NICU stay. Infections were defined using standard Centers for Disease Control and Prevention definitions adapted to neonatal pathology and were considered to be healthcare-associated if they developed >2 days after NICU admission. RESULTS: One hundred-fifty-three HAIs were diagnosed with a frequency of 9% and an incidence density of 3.5 per 1000 days of hospital stay. HAIs developed in all BW classes, but patients weighing≤1000 g at birth were more affected with a decreasing trend from the lowest to the highest BW classes. Sepsis proved to be the most frequent infection (44.4%), followed by urinary tract infection (UTI) (28.8%), pneumonia (25.5%) and meningitis (1.3%). Device associated infections (i.e. central line-associated bloodstream infections (BSIs), umbilical catheter-associated BSI and ventilator associated pneumonias (VAPs) represented 64.1% of all HAIs. Most frequent pathogens responsible for all types of infections were: P. aeruginosa (17%), C. parapsilosis (16.3%), E. coli (13.1%), C. albicans (10.5%), non- extended spectrum beta-lactamase (ESBL) K. pneumoniae (7.8%), and coagulase-negative Staphylococci (5.2%). No microbiological diagnosis was achieved for 6.5% of infections. CONCLUSIONS: HAIs developed in all BW classes but low BW neonates were at major risk to acquire HAIs in our NICU. Use of central line-, umbilical-catheter and mechanical ventilation was associated with higher risk of infection. Our findings highlight the importance of an extensive surveillance approach in the NICU setting, which includes all BW classes of neonates and monitors infections associated with the use of medical devices.


Asunto(s)
Infección Hospitalaria/epidemiología , Unidades de Cuidado Intensivo Neonatal/estadística & datos numéricos , Peso al Nacer , Infección Hospitalaria/microbiología , Infección Hospitalaria/prevención & control , Femenino , Humanos , Incidencia , Recién Nacido , Control de Infecciones , Italia/epidemiología , Tiempo de Internación , Masculino , Neumonía Asociada al Ventilador/epidemiología , Neumonía Asociada al Ventilador/microbiología , Neumonía Asociada al Ventilador/prevención & control , Factores de Riesgo , Sepsis/epidemiología , Sepsis/microbiología , Sepsis/prevención & control , Infecciones Urinarias/epidemiología , Infecciones Urinarias/microbiología , Infecciones Urinarias/prevención & control
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA