Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Radiol Med ; 127(3): 277-293, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35129758

RESUMEN

Non-invasive cardiovascular imaging owns a pivotal role in the preoperative assessment of patient candidates for transcatheter aortic valve implantation (TAVI), providing a wide range of crucial information to select the patients who will benefit the most and have the procedure done safely. This document has been developed by a joined group of experts of the Italian Society of Cardiology and the Italian Society of Medical and Interventional Radiology and aims to produce an updated consensus statement about the pre-procedural imaging assessment in candidate patients for TAVI intervention. The writing committee consisted of members and experts of both societies who worked jointly to develop a more integrated approach in the field of cardiac and vascular radiology. Part 2 of the document will cover CT and MR angiography, standard medical reporting, and future perspectives.


Asunto(s)
Estenosis de la Válvula Aórtica , Cardiología , Reemplazo de la Válvula Aórtica Transcatéter , Angiografía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Tomografía Computarizada por Rayos X/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos
2.
J Cardiovasc Electrophysiol ; 31(8): 2187-2191, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32495408

RESUMEN

INTRODUCTION: The most appropriate treatment for stroke prevention in standalone atrial fibrillation patients with a high CHADS2VASC score contraindicated for oral anticoagulation (OAC) or novel OAC (NOAC) still needs to be defined. Percutaneous left atrial appendage (LAA) closure devices are available, but because of their endocardial positioning need a period of antiplatelet therapy (APT). This study aimed to evaluate the safety and efficacy of epicardial left atrial appendage clipping in patients contraindicated for (N)OAC and APT. METHODS AND RESULTS: We describe a standalone totally thoracoscopic LAA clipping of forty-five consecutive patients with nonvalvular atrial fibrillation (NVAF; 32 males; age, 73.1 ± 7.4 years; CHADVASC, 6.5 ± 1.1; HAS-BLED 4.9 ± 0.9) with absolute contraindications to (N)OAC. The patients were selected by a multidisciplinary Heart Team. Sixty percent had a previous ischemic stroke and 51% a history of the hemorrhagic event and 22% both. All patients were implanted with an LAA epicardial clip, guided by preoperative computed tomography and intraoperative transesophageal echocardiography. The mean procedural duration was 52.3 ± 12.6 minutes with postprocedural extubation interval of 22.8 ± 14.6 minutes. No procedure-related complications occurred. Intraprocedural transesophageal echocardiography (TEE) showed complete LAA occlusion in all patients. At a mean follow-up of 16.4 ± 9.1 months (range, 2-34), with all patients off (N)OAC or APT, no ischemic stroke or hemorrhagic complications occurred. computed tomography or TEE at follow-up demonstrated a correct LAA occlusion in all with mean stumps of 3.3 ± 2.8 mm. CONCLUSION: Thoracoscopic epicardial closure of the LAA with the AtriClip PRO2 device is a potentially safe and efficient treatment for stroke prevention in patients with NVAF contraindicated for anticoagulant therapy or APT.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Isquemia Encefálica , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Anciano , Anticoagulantes/efectos adversos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/diagnóstico por imagen , Ecocardiografía Transesofágica , Humanos , Masculino , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento
3.
Radiol Med ; 125(11): 1200-1207, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32970273

RESUMEN

Cardiovascular diseases are still among the first causes of death worldwide with a huge impact on healthcare systems. Within these conditions, the correct diagnosis of coronary artery disease with the most appropriate imaging-based evaluations is of utmost importance. The sustainability of the healthcare systems, considering the high economic burden of modern cardiac imaging equipments, makes cost-effective analysis an important tool, currently used for weighing different costs and health outcomes, when policy makers have to allocate funds and to prioritize interventions, getting the most out of their financial resources. This review aims at evaluating cost-effective analysis in the more recent literature, focused on the role of Calcium Score, coronary computed tomography angiography and cardiac magnetic resonance.


Asunto(s)
Técnicas de Imagen Cardíaca/economía , Angiografía por Tomografía Computarizada/economía , Angiografía Coronaria/economía , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Imagen por Resonancia Magnética/economía , Calcificación Vascular/diagnóstico por imagen , Análisis Costo-Beneficio , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos
4.
Radiol Med ; 121(1): 12-8, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26210815

RESUMEN

PURPOSE: To establish the appropriate number of Cardiac-CT and Cardio-MR examinations, to determine an economically justified and sustainable investment in these two technologies, for an exclusive cardiologic use. MATERIALS AND METHODS: From July 2013 to July 2014, through a survey in four different Italian Departments of Radiology, data on the costs of Cardiac-CT and Cardiac-MR examinations were collected. For the evaluation of the costs of examinations, it was used an analytical accounting system, considering only the direct costs (consumables, health personnel work time, equipment amortization/maintenance) and other costs (utilities, services, etc.). Indirect costs (general costs) were not assessed. It was made a simulation, assuming an exclusive use of the CT and MR equipments for Cardiac-CT and Cardiac-MR examinations, calculating the annual number necessary to arrive at the Break Even Point (BEP: the point at which cost or expenses and revenue are equal). RESULTS: On the basis of the CT costs, in order to reach the BEP, performing only Cardiac-CT examinations, an average of 2641-2752 examinations/year is needed. The annual time commitment of the Medical Professional to ensure the number of examinations to reach the BEP is 2625-2750 h/year, equivalent to two Medical Doctors in a Cardiology Department. The recent Cardiac-CT Italian Registry, in the period January-June 2011, reports a number of examinations of 3455 patients in 47 different Centers, distributed throughout the whole national territory. With regard to MR, in order to reach the BEP, performing only Cardiac-MR examinations, an average of 2435-3123 examinations/year is needed. The annual time commitment of the Medical Professional to ensure the number of examinations to reach the BEP is 2437-3125 h/year, equivalent to two Medical Doctors in a Cardiology Department. The recent Cardiac-MR Italian Registry reports a number of examinations of 3776 patients in 40 Centers, distributed throughout the whole national territory. CONCLUSION: This research has shown that, only on the basis of costs, currently in Italy is anti-economic an exclusive use of CT or MR equipment for cardiac exams, unless it's not decided, regardless of the recent guidelines and clinical indications, to submit all patients with cardiac diseases (diseases of the coronary arteries and cardiomyopathies) to Cardiac-CT and Cardiac-MR examinations. This might likely to increase both the inappropriate examinations and either health spending and in the case of CT with important repercussions, in terms of radio-exposure, subject to forensic procedures.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico , Costos y Análisis de Costo , Imagen por Resonancia Magnética/economía , Imagen por Resonancia Magnética/estadística & datos numéricos , Tomografía Computarizada por Rayos X/economía , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Enfermedades Cardiovasculares/diagnóstico por imagen , Humanos , Italia , Sistema de Registros , Encuestas y Cuestionarios
5.
Radiol Med ; 119(8): 595-600, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24297596

RESUMEN

PURPOSE: This study was done to identify left atrial fibrosis in a group of consecutive patients with atrial fibrillation (AF) candidate for percutaneous radiofrequency catheter ablation (RFCA) by using a late-enhancement magnetic resonance (LE-MR) sequence, and to validate the technique by comparison with electroanatomical mapping (EAM). MATERIALS AND METHODS: We enrolled 37 patients (29 males; mean age, 61 years) candidate for percutaneous RFCA of AF, who were studied with LE-MR and EAM. To identify left AF we used a three-dimensional LE sequence with cardiac gating and respiratory navigator. The EAM study involved the acquisition of 200 points in the left atrium (LA). The LA was divided into seven segments (pulmonary vein antra, floor, anterior wall, posterior wall-roof). Two blinded radiologists assessed the presence of fibrosis (area of hyperintense signal), reaching a consensus in discordant cases. Inter-observer variability was also evaluated to estimate the reproducibility of the method. We analysed the anatomical agreement between the results obtained with LE-MR imaging and EAM. RESULTS: Five patients were excluded because of to poor image quality. As for the other 32 patients, inter-observer agreement was good [Cohen's kappa κ = 0.72 with 95 % confidence interval (CI) of 0.55, 0.89]. In the classification of LA segments affected by fibrosis, LE-MR had a sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of 66 % (95 % CI 53.7 %, 77.2 %); 87 % (95 % CI 80.9 %, 91.9 %); 69 % (95 % CI 56.5 %, 80.1 %); 85.5 % (95 % CI 79.1 %, 90.6 %) and 81 % (95 % CU 75.1 %, 85.7 %). CONCLUSIONS: Despite the small size of the sample studied, the LE-MR sequence proved more useful for excluding the presence of AF than for confirming its existence. Identification of AF prior to RFCA is paramount to select those patients who are truly amenable to the ablation procedure, which is expensive and not entirely free of risks.


Asunto(s)
Atrios Cardíacos/patología , Aumento de la Imagen , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Femenino , Fibrosis/diagnóstico , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Factores de Tiempo
6.
J Cardiovasc Med (Hagerstown) ; 24(3): 191-199, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36753726

RESUMEN

AIMS: To assess the characteristics of left atrial appendage (LAA) stump and left atrial (LA) volume after standalone totally thoracoscopic LAA exclusion in 40 patients with nonvalvular atrial fibrillation (NVAF) and contraindications to oral anticoagulation (OAC), using cardiac computed tomography (CCT) and transoesophageal echocardiography (TOE). METHODS: Using CCT and TOE, we evaluated correct AtriClip Pro II positioning, the presence and characteristics of the LAA stump and the postprocedural LA volume, at 3 months' follow-up. Stump depth was measured with both CCT and TOE using a new method, based on left circumflex artery (LCX) course. RESULTS: After placement of AtriClip, all 40 patients discontinued OAC, and no stroke occurred. LAA exclusion was achieved in 40/40 patients at 3 months' follow-up. LAA stump (depth <10 mm in 12/18 stump, 67%) was observed in 18 patients. The overall (LA + LAA) volume and isolated LA volume were statistically different when comparing cases with and without LAA stump (P < 0.02). LAA ostium dimensions (perimeter and area) and LAA volume correlate with stump depth (P < 0.02). There was a high correlation between CCT and TOE in stump identification and depth measurement (P < 0.02). Compared with the baseline, CCT LA volume increased (P < 0.01) at 3 months' follow-up. CONCLUSION: Preprocedural and postprocedural CCT and TOE are useful and comparable in patients undergoing standalone totally thoracoscopic exclusion of LAA, because these imaging methods can identify anatomical LAA and LA characteristics predisposing for a postprocedural residual stump.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Ecocardiografía Transesofágica , Accidente Cerebrovascular/etiología
7.
Indian Pacing Electrophysiol J ; 12(6): 237-49, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23233757

RESUMEN

BACKGROUND: Cryoballoon ablation (CBA) has been proven to be very effective for pulmonary vein (PV) isolation (PVI) if complete occlusion is achieved and conventionally assessed by angiographic injection of contrast within PV lumen. The aim of our study was to assess the usefulness of saline contrast intracardiac echocardiography in guiding CBA with respect to PV angiography. METHODS: Thirty consecutive patients with paroxysmal atrial fibrillation were randomly assigned fluoroscopy plus color-flow Doppler (n = 15; group 1: an iodinated medium as both angiographic and echographic contrast) or contrast intracardiac echocardiography plus color-flow Doppler (n = 15; group 2: saline contrast) for guidance of CBA. RESULTS: We evaluated 338 occlusions of 107 PVs. The intracardiac echocontrastography-guided assessment of occlusion, defined as loss of echocontrastographic back-flow to the left atrium after saline injection regardless of the visualization of PV antrum, showed a high level of agreement with the angiographic diagnosis of occlusion. PVI rate was similar in both groups and effectively guided by intracardiac echocontrastography (PVI using ≤ 2 double cryofreezes: 89% of PVs in group 1 vs. 91% in group 2; p=n.s.). Group 2 patients had significantly shorter procedure (127 ± 16 vs. 152 ± 19 minutes; p<0.05) and fluoroscopy times (30 ± 12 vs. 43 ± 9 minutes, p<0.05) and used a lower iodinated contrast (88 ± 26 vs. 190 ± 47 mL, p<0.05). CONCLUSIONS: PV occlusion and PVI during cryoablation can be effectively predicted by intracardiac saline echocontrastography. This technique reduces procedural time, radiological exposure and iodinated contrast use.

8.
Med Biol Eng Comput ; 60(8): 2307-2319, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35729476

RESUMEN

This work dealt with the assessment of a computational tool to estimate the electrical activation in the left ventricle focusing on the latest electrically activated segment (LEAS) in patients with left bundle branch block and possible myocardial fibrosis. We considered the Eikonal-diffusion equation and to recover the electrical activation maps in the myocardium. The model was calibrated by using activation times acquired in the coronary sinus (CS) branches or in the CS solely with an electroanatomic mapping system (EAMS) during cardiac resynchronization therapy (CRT). We applied our computational tool to ten patients founding an excellent accordance with EAMS measures; in particular, the error for LEAS location was less than 4 mm. We also calibrated our model using only information in the CS, still obtaining an excellent agreement with the measured LEAS. The proposed tool was able to accurately reproduce the electrical activation maps and in particular LEAS location in the CS branches, with an almost real-time computational effort, regardless of the presence of myocardial fibrosis, even when information only at CS was used to calibrate the model. This could be useful in the clinical practice since LEAS is often used as a target site for the left lead placement during CRT. Overall picture of the computational pipeline for the estimation of LEAS.


Asunto(s)
Terapia de Resincronización Cardíaca , Seno Coronario , Insuficiencia Cardíaca , Bloqueo de Rama/terapia , Dispositivos de Terapia de Resincronización Cardíaca , Fibrosis , Humanos , Resultado del Tratamiento
9.
J Cardiovasc Med (Hagerstown) ; 23(4): 216-227, 2022 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-35287156

RESUMEN

Non-invasive cardiovascular imaging owns a pivotal role in the preoperative assessment of patients for transcatheter aortic valve implantation (TAVI), providing a wide range of crucial information to select the patients who will benefit the most and have the procedure done safely. Although advanced cardiac imaging with cardiac computed tomography is routinely used for a detailed anatomic assessment before TAVI, echocardiography remains the first imaging modality to assess aortic stenosis severity and to provide essential functional information. This document results from the collaboration between the Italian Society of Cardiology (SIC) and the Italian Society of Medical and Interventional Radiology (SIRM), aiming to produce an updated consensus statement about the pre-procedural imaging assessment in patient for TAVI. The writing committee is composed of radiologists and cardiologists, experts in the field of cardiac imaging and structural heart diseases. Part 1 of the document, after a brief overview of the clinical indication and basic technical aspects of TAVI, will focus on the role of echocardiography in TAVI pre-procedural planning.


Asunto(s)
Estenosis de la Válvula Aórtica , Cardiología , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Ecocardiografía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Radiología Intervencionista , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos
10.
Ann Thorac Surg ; 111(1): e61-e63, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32569667

RESUMEN

Totally thoracoscopic standalone left atrial appendage exclusion has become a valid treatment option for stroke prevention in patients with a contraindication to anticoagulants. As with most other video-assisted surgeries, this procedure requires appropriate patient and port positioning to obtain the most advantageous working angles and standard thoracoscopic skills. Furthermore it is mandatory to have a closure device specifically designed for the appendage to guarantee efficacy and safety and to optimize surgical placement that allows the best clinical outcomes. Here we describe the surgical technique of a unilateral left-sided thoracoscopic approach for surgical exclusion of the appendage on the beating heart.


Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Accidente Cerebrovascular/prevención & control , Toracoscopía/métodos , Procedimientos Quirúrgicos Cardíacos/métodos , Procedimientos Quirúrgicos Cardíacos/normas , Humanos
11.
Phys Med ; 78: 15-31, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32911373

RESUMEN

PURPOSE: Ventricular tachycardia (VT) is a life-threatening heart disorder. The aim of this preliminary study is to assess the feasibility of stereotactic body radiation therapy (SBRT) photon and proton therapy (PT) plans for the treatment of VT, adopting robust optimization technique for both irradiation techniques. METHODS: ECG gated CT images (in breath hold) were acquired for one patient. Conventional planning target volume (PTV) and robust optimized plans (25GyE in single fraction) were simulated for both photon (IMRT, 5 and 9 beams) and proton (SFO, 2 beams) plans. Robust optimized plans were obtained both for protons and photons considering in the optimization setup errors (5 mm in the three orthogonal directions), range (±3.5%) and the clinical target volume (CTV) motion due to heartbeat and breath-hold variability. RESULTS: The photon robust optimization method, compared to PTV-based plans, showed a reduction in the average dose to the heart by about 25%; robust optimization allowed also reducing the mean dose to the left lung from 3.4. to 2.8 Gy for 9-beams configuration and from 4.1 to 2.9 Gy for 5-beams configuration. Robust optimization with protons, allowed further reducing the OAR doses: average dose to the heart and to the left lung decreased from 7.3 Gy to 5.2 GyE and from 2.9 Gy to 2.2 GyE, respectively. CONCLUSIONS: Our study demonstrates the importance of the optimization technique adopted in the treatment planning system for VT treatment. It has been shown that robust optimization can significantly reduce the dose to healthy cardiac tissues and that PT further increases this gain.


Asunto(s)
Terapia de Protones , Radiocirugia , Taquicardia Ventricular , Electrocardiografía , Humanos , Fotones , Protones , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Taquicardia Ventricular/diagnóstico por imagen
12.
World J Cardiol ; 12(6): 248-261, 2020 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-32774777

RESUMEN

The diagnosis of myocardial infarction with non-obstructive coronary arteries (MINOCA) necessitates documentation of an acute myocardial infarction (AMI), non-obstructive coronary arteries, using invasive coronary angiography or coronary computed tomography angiography and no clinically overt cause for AMI. Historically patients with MINOCA represent a clinical dilemma with subsequent uncertain clinical management. Differential diagnosis is crucial to choose the best therapeutic option for ischemic and non-ischemic MINOCA patients. Cardiovascular magnetic resonance (CMR) is able to analyze cardiac structure and function simultaneously and provides tissue characterization. Moreover, CMR could identify the cause of MINOCA in nearly two-third of patients providing valuable information for clinical decision making. Finally, it allows stratification of patients with worse outcomes which resulted in therapeutic changes in almost half of the patients. In this review we discuss the features of CMR in MINOCA; from exam protocols to imaging findings.

13.
Comput Biol Med ; 127: 104047, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33099220

RESUMEN

In this work we address the issue of validating the monodomain equation used in combination with the Bueno-Orovio ionic model for the prediction of the activation times in cardiac electro-physiology of the left ventricle. To this aim, we consider four patients who suffered from Left Bundle Branch Block (LBBB). We use activation maps performed at the septum as input data for the model and maps at the epicardial veins for the validation. In particular, a first set (half) of the latter are used to estimate the conductivities of the patient and a second set (the remaining half) to compute the errors of the numerical simulations. We find an excellent agreement between measures and numerical results. Our validated computational tool could be used to accurately predict activation times at the epicardial veins with a short mapping, i.e. by using only a part (the most proximal) of the standard acquisition points, thus reducing the invasive procedure and exposure to radiation.


Asunto(s)
Terapia de Resincronización Cardíaca , Técnicas Electrofisiológicas Cardíacas , Arritmias Cardíacas , Bloqueo de Rama , Electrocardiografía , Ventrículos Cardíacos , Humanos
14.
Eur Radiol ; 19(5): 1114-23, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19089430

RESUMEN

This was a prospective, multicenter study designed to evaluate the utility of MDCT in the diagnosis of coronary artery disease (CAD) in patients scheduled for elective coronary angiography (CA) using different MDCT systems from different manufacturers. Twenty national sites prospectively enrolled 367 patients between July 2004 and June 2006. Computed tomography (CT) was performed using a standardized/optimized scan protocol for each type of MDCT system (> or =16 slices) and compared with quantitative CA performed within 2 weeks of MDCT. A total of 284 patients (81%) were studied by 16-slice MDCT systems, while 66 patients (19%) by 64-slice MDCT scanners. The primary analysis was on-site/off-site evaluation of the negative predictive value (NPV) on a per-patient basis. Secondary analyses included on-site evaluation on a per-artery and per-segment basis. On-site evaluation included 327 patients (CAD prevalence 58%). NPV, positive predictive value (PPV), sensitivity, specificity, and diagnostic accuracy (DA) were 0.91 (95% CI 0.85-0.95), 0.91 (95% CI 0.86-0.95), 0.94 (95% CI 0.89-0.97), 0.88 (95% CI 0.81-0.93), and 0.91 (95% CI 0.88-0.94), respectively. Off-site analysis included 295 patients (CAD prevalence 56%). NPV, PPV, sensitivity, specificity, and DA were 0.73 (95% CI 0.65-0.79), 0.93 (95% CI 0.87-0.97), 0.73 (95% CI 0.65-0.79), 0.93 (95% CI 0.87-0.97), and 0.82 (95% CI 0.77-0.86), respectively. The results of this study demonstrate the utility of MDCT in excluding significant CAD even when conducted by centers with varying degrees of expertise and using different MDCT machines.


Asunto(s)
Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/diagnóstico , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Diagnóstico por Imagen/métodos , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados
16.
Med Eng Phys ; 30(1): 48-58, 2008 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17392015

RESUMEN

The delineation of left atrium (LA) and pulmonary veins (PVs) anatomy from high resolution images holds importance for atrial fibrillation (AF) investigation and treatment. In this study, a semiautomatic segmentation procedure for LA and PVs inner surface from contrast enhanced CT data was developed. The procedure consists of a three dimensional marker controlled watershed segmentation applied to the external morphological gradient, followed by variable threshold surface extraction from the original intensity image. A preliminary anisotropic non-linear filtering was implemented to improve the S/N ratio of CT images. The performance of segmentation was evaluated on cardiac CT scans of 12 AF patients both qualitatively and quantitatively. The qualitative evaluation by expert radiologist assessed the segmentation as overall successful in all patients and capable of extracting both the LA body and the connected vascular trees. The quantitative validation, by computing discrepancy measures with respect to a manually segmented gold standard, indicated an average of about 90% of voxels correctly classified and an average border mismatch lower than 1.5 voxels (1.2 mm). The accurate extraction of the inner LA-PVs walls provided by this method, along with the minimal required human intervention, should facilitate the use of anatomical atrial models for the non-pharmacological treatment of AF.


Asunto(s)
Atrios Cardíacos/diagnóstico por imagen , Técnica de Sustracción , Tomografía Computarizada por Rayos X/métodos , Anatomía Regional , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/patología , Medios de Contraste , Atrios Cardíacos/patología , Humanos , Imagenología Tridimensional/métodos , Modelos Cardiovasculares , Reconocimiento de Normas Patrones Automatizadas/métodos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/patología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
17.
Phys Med Biol ; 52(20): 6323-37, 2007 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-17921587

RESUMEN

The integration of electroanatomic maps with highly resolved computed tomography cardiac images plays an important role in the successful planning of the ablation procedure of arrhythmias. In this paper, we present and validate a fully-automated strategy for the registration and fusion of sparse, atrial endocardial electroanatomic maps (CARTO maps) with detailed left atrial (LA) anatomical reconstructions segmented from a pre-procedural MDCT scan. Registration is accomplished by a parameterized geometric transformation of the CARTO points and by a stochastic search of the best parameter set which minimizes the misalignment between transformed CARTO points and the LA surface. The subsequent fusion of electrophysiological information on the registered CT atrium is obtained through radial basis function interpolation. The algorithm is validated by simulation and by real data from 14 patients referred to CT imaging prior to the ablation procedure. Results are presented, which show the validity of the algorithmic scheme as well as the accuracy and reproducibility of the integration process. The obtained results encourage the application of the integration method in post-intervention ablation assessment and basic AF research and suggest the development for real-time applications in catheter guiding during ablation intervention.


Asunto(s)
Algoritmos , Fibrilación Atrial/diagnóstico , Mapeo del Potencial de Superficie Corporal/métodos , Imagenología Tridimensional/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Técnica de Sustracción , Tomografía Computarizada por Rayos X/métodos , Inteligencia Artificial , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Procesos Estocásticos
18.
Eur J Radiol ; 59(2): 222-30, 2006 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16616823

RESUMEN

OBJECTIVE: Assess mammographic and echographic modifications in mild cases of breast cancer (suitable for conservative surgery) after intraoperatory radio treatment (IORT) as opposed to conventional post-operative radiotherapy (RT). MATERIALS AND METHODS: We report data from 45 patients in each group (IORT and RT). All patients were examined using the same mammographic and ecographic equipment at 6, 12 and 24 months after treatment. We focused on structural alterations, edema and others, and quantified them using pre-established (unbiased) protocols. Both patient examination and subsequent assessment of the results were performed by radiologists with exepertise in breast cancer evaluation. RESULTS: At 6 months, IORT patients showed slightly more pronounced structural distortions and oedema than RT patients; these differences became more apparent at 12 months, with the addition of fat necrosis and/or calcifications. These alterations were evident and consistent under both mammographic and ecographic examination, and became even more pronounced at 24 months. At this stage, RT patients showed minimal alterations of the tissue (apart from normal post-surgical scarring), whereas IORT patients showed virtually no improvement over the preceding 12-month period. CONCLUSION: We show radiological alterations in post-operative breast cancer are significantly more pronounced in patients treated with IORT as opposed to RT.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/radioterapia , Carcinoma Ductal de Mama/diagnóstico , Carcinoma Ductal de Mama/radioterapia , Mamografía , Ultrasonografía Mamaria , Anciano , Neoplasias de la Mama/cirugía , Carcinoma Ductal de Mama/cirugía , Terapia Combinada , Femenino , Estudios de Seguimiento , Humanos , Periodo Intraoperatorio , Persona de Mediana Edad , Estadificación de Neoplasias , Periodo Posoperatorio , Radioterapia Adyuvante , Resultado del Tratamiento
19.
Insights Imaging ; 7(1): 99-110, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26555392

RESUMEN

UNLABELLED: Cardiac magnetic resonance (CMR) is considered a primary tool for the diagnosis of acute myocarditis, due to its unique potential for non-invasive identification of the various hallmarks of the inflammatory response, with relevant impact on patient management and prognosis. Nonetheless, a marked variation in sensitivity and negative predictive value has been reported in the literature, reflecting the intrinsic drawbacks of current diagnostic criteria, which are based mainly on the use of conventional CMR pulse sequences. As a consequence, a negative exam cannot reliably exclude the diagnosis, especially in patients who do not present an infarct-like onset of disease. The introduction of new-generation mapping techniques further widened CMR potentials, allowing quantification of tissue changes and opening new avenues for non-invasive workup of patients with inflammatory myocardial disease. MAIN MESSAGES: • CMR sensitivity varies in AM, reflecting its clinical polymorphism and the intrinsic drawbacks of LLc. • Semiquantitative approaches such as EGEr or T2 ratio have limited accuracy in diffuse disease forms. • T1 mapping allows objective quantification of inflammation, with no need to normalize measurements. • A revised protocol including T2-STIR, T1 mapping and LGE could be hypothesized to improve sensitivity.

20.
Int J Numer Method Biomed Eng ; 30(12): 1558-77, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25319252

RESUMEN

To properly describe the electrical activity of the left ventricle, it is necessary to model the Purkinje fibers, responsible for the fast and coordinate ventricular activation, and their interaction with the muscular propagation. The aim of this work is to propose a methodology for the generation of a patient-specific Purkinje network driven by clinical measurements of the activation times related to pathological propagations. In this case, one needs to consider a strongly coupled problem between the network and the muscle, where the feedback from the latter to the former cannot be neglected as in a normal propagation. We apply the proposed strategy to data acquired on three subjects, one of them suffering from muscular conduction problems owing to a scar and the other two with a muscular pre-excitation syndrome (Wolff-Parkinson-White). To assess the accuracy of the proposed method, we compare the results obtained by using the patient-specific Purkinje network generated by our strategy with the ones obtained by using a non-patient-specific network. The results show that the mean absolute errors in the activation time is reduced for all the cases, highlighting the importance of including a patient-specific Purkinje network in computational models.


Asunto(s)
Simulación por Computador , Sistema de Conducción Cardíaco , Modelos Cardiovasculares , Ramos Subendocárdicos , Anciano , Femenino , Sistema de Conducción Cardíaco/anatomía & histología , Sistema de Conducción Cardíaco/fisiología , Humanos , Masculino , Persona de Mediana Edad , Ramos Subendocárdicos/anatomía & histología , Ramos Subendocárdicos/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA