Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Radiat Prot Dosimetry ; 199(8-9): 835-842, 2023 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-37225222

RESUMEN

Industrial processes generate various quantities of waste that can be contaminated with radionuclides of natural origin (naturally occurring radioactive material ('NORM waste')). The efficient management of this waste is essential for any industries affected by NORM waste generation. To obtain an overview of current practices and approaches in Europe, the IRPA Task Group on NORM conducted a survey among task group members and other experts from European countries. The results revealed significant differences in methods and approaches in the European countries. In many countries, landfills are used to dispose of small- and medium-sized quantities of NORM waste with limited activity concentration. But our survey indicated that despite a uniform reference basis for national legislation in Europe, there are different framework conditions for the disposal of NORM waste in practice. In some countries, the disposal is hampered because the interface between the radiation protection system and the waste regime is not yet clearly regulated. Particular practical problems include the lack of acceptance of waste because of the 'radioactivity' stigma and only vague specifications by the legislators on acceptance obligations of the waste management sector.


Asunto(s)
Protección Radiológica , Eliminación de Residuos , Administración de Residuos , Europa (Continente) , Industrias
2.
Heliyon ; 9(9): e19368, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37809884

RESUMEN

During the COVID-19 pandemic, there was a shortage of personal protective equipment, PPE, which resulted in non-certified PPE being used by healthcare staffs. These would not provide the appropriate protection against the SARS-CoV-2 virus. Together with the local NHS Trust (University Hospitals of Derby and Burton (UHDB) NHS Foundation Trust) and a local small and medium enterprise (SME), Riverside Medical Packaging Ltd, the University of Derby (UoD) developed test protocols for PPE with a one-size-fits-all concept. Building on best practice in reviewing the literature and current design requirements, key design parameters were identified such as a minimum strap width and comfort level for healthcare related Face Shield. Two strap headbands made from fabric and elastomer with linear stiffness of 44.1 ± 0.3 N/m and 149.1 ± 3.1 N/m respectively were tested with respect to fit and comfort on small and large arc-shaped models. There was an exponential change in pressure from the side to the middle of the strap headbands. The high stiffness of the elastomer in a radial set-up influenced the pressure exerted on a wearer's head when the elastomer strap was used. Meanwhile the coefficient of friction between the fabric strap and arc-shaped model influenced the pressure exerted when a fabric strap was used. The ergonomics of the designed Face Shields supported the one-size-fits-all concept, whereby various gender and head circumferences were considered. The findings in this paper will promote new standards in the design of PPE with a one-size-fits-all target.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA