Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 99(6): 1829-1838, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35324050

RESUMEN

OBJECTIVES: Report contemporary outcomes in patients included in the Mitragister registry and treated with transcatheter mitral valve implantation for failed surgical annuloplasty rings or deteriorated bioprosthesis. BACKGROUND: Midterm survival rates have been reported, but little is known about contemporary morbimortality endpoints. METHODS: The primary safety outcome was the technical success rate. The primary efficacy composite endpoint was a composite of cardiovascular mortality and heart failure hospitalizations. RESULTS: From 2016 to 2021, 102 patients (median age: 81 [74;84] years, 61% female, Euroscore II 11.0% [7.8;16.0]) undergoing valve-in-valve (ViV; n = 89) or valve-in-ring (ViR; n = 13) procedures were consecutively included. At baseline, ViR group patients had worse left ventricular ejection fraction (50% vs. 60%; p = 0.004) and more frequently severe regurgitation (46% vs. 15%; p = 0.014). The primary safety outcome was 95%: 77% and 98% in the ViR and ViV populations, respectively, (p = 0.014). At intermediate follow-up (6-12 months) clinical improvement was notable, 88% of the patients were in NYHA class ≤ II (vs. 25% at baseline; p < 0.001). At a mean follow-up of 17.1 ± 11.0 months, the primary efficacy composite reached 27%. By multivariate analysis, paravalvular leak (PVL) was the only independent predictor (hazard ratio: 2.39, 95% confidence interval: 1.08-5.29; p = 0.031) while ViR was not found statistically associated (p = 0.456). CONCLUSIONS: This study confirms the safety and efficacy of the mitral ViV procedure. ViR patients appear at higher risk of procedural complications. The presence of PVL could be associated with markedly worse midterm prognosis. Whatever the intervention, procedural strategies to reduce PVL incidence remain to be assessed to prevent latter adverse outcomes.


Asunto(s)
Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Anciano de 80 o más Años , Bioprótesis/efectos adversos , Cateterismo Cardíaco/métodos , Femenino , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Falla de Prótesis , Sistema de Registros , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
2.
Circulation ; 141(4): 243-259, 2020 01 28.
Artículo en Inglés | MEDLINE | ID: mdl-31736356

RESUMEN

BACKGROUND: No randomized study powered to compare balloon expandable (BE) with self expanding (SE) transcatheter heart valves (THVs) on individual end points after transcatheter aortic valve replacement has been conducted to date. METHODS: From January 2013 to December 2015, the FRANCE-TAVI nationwide registry (Registry of Aortic Valve Bioprostheses Established by Catheter) included 12 141 patients undergoing BE-THV (Edwards, n=8038) or SE-THV (Medtronic, n=4103) for treatment of native aortic stenosis. Long term mortality status was available in all patients (median 20 months; interquartile range, 14 to 30). Patients treated with BE-THV (n=3910) were successfully matched 1:1 with 3910 patients treated with SE-THV by using propensity score (25 clinical, anatomical, and procedural variables) and by date of the procedure (within 3 months). The first coprimary outcome was ≥ moderate occurrence of paravalvular regurgitation or in-hospital mortality, or both. The second coprimary outcome was 2-year all-cause mortality. RESULTS: In propensity-matched analyses, the incidence of the first coprimary outcome was higher with SE-THV (19.8%) compared with BE-THV (11.9%; relative risk, 1.68 [95% CI, 1.46-1.91]; P<0.0001). Each component of the outcome was also higher in patients receiving SE-THV: ≥ moderate paravalvular regurgitation (15.5% versus 8.3%; relative risk, 1.90 [95% CI, 1.63-2.22]; P<0.0001) and in hospital mortality (5.6% versus 4.2%; relative risk, 1.34 [95% CI, 1.07-1.66]; P=0.01). During follow up, all cause mortality occurred in 899 patients treated with SE-THV (2-year mortality, 29.8%) and in 801 patients treated with BE-THV (2-year mortality, 26.6%; hazard ratio, 1.17 [95% CI, 1.06-1.29]; P=0.003). Similar results were found using inverse probability of treatment weighting using propensity score analysis. CONCLUSION: The present study suggests that use of SE-THV was associated with a higher risk of paravalvular regurgitation and higher in-hospital and 2-year mortality compared with use of BE-THV. These data strongly support the need for a randomized trial sufficiently powered to compare the latest generation of SE-THV and BE-THV. CLINICAL TRIAL REGISTRATION: https://www.clinicaltrials.gov. Unique identifier: NCT01777828.


Asunto(s)
Prótesis Valvulares Cardíacas , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Supervivencia sin Enfermedad , Femenino , Estudios de Seguimiento , Francia/epidemiología , Humanos , Masculino , Tasa de Supervivencia
3.
Catheter Cardiovasc Interv ; 98(4): 788-799, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34051135

RESUMEN

OBJECTIVES: The French left atrial appendage (LAA) closure registry (FLAAC) aimed to assess the safety and efficacy of LAA closure in daily practice. BACKGROUND: LAA closure has emerged as an alternative for preventing thromboembolic events (TE) in patients with non-valvular atrial fibrillation (NVAF). Clinical data in this field remains limited and few investigator-initiated, real-world registries have been reported. METHODS: This nationwide, prospective study was performed in 36 French centers. The primary endpoint was the TE rate after successful LAA closure. RESULTS: The FLAAC registry included 816 patients with a mean age of 75.5 ± 0.3 years, mean follow-up of 16.0 ± 0.3 months, high TE (CHA2 DS2 -VASc score: 4.6 ± 0.1) and bleeding risks (HAS-BLED score: 3.2 ± 0.05) and common contraindications to long-term anticoagulation (95.7%). Procedure or device-related serious adverse events occurred in 49 (6.0%) patients. The annual rate of ischemic stroke/systemic embolism was 3.3% (2.4-4.6). This suggests a relative 57% reduction compared to the risk of stroke in historical NVAF populations without antithrombotic therapy. By multivariate analysis, history of TE was the only factor associated with stroke/systemic embolism during follow-up (HR, 3.3 [1.58-6.89], p = 0.001). The annual mortality rate was 10.2% (8.4-12.3). Most of the deaths were due to comorbidities or underlying cardiovascular diseases and unrelated to the device or to TE. CONCLUSIONS: Our study suggests that LAA closure can be an option in patients with NVAF. Long-term follow-up mortality was high, mostly due to comorbidities and underlying cardiovascular diseases, highlighting the importance of multidisciplinary management after LAA closure. REGISTRATION: NCT02252861.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Anciano , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Humanos , Estudios Prospectivos , Sistema de Registros , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento
4.
Catheter Cardiovasc Interv ; 88(6): 988-993, 2016 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-27510946

RESUMEN

OBJECTIVES: We sought to demonstrate the safety and efficacy of rapid left ventricular (LV) pacing through the guidewire during balloon aortic valvuloplasty (BAV) and Transaortic valve implantation (TAVI). BACKGROUND: Right ventricular temporary pacing during TAVI and BAV is time-consuming and associated with vascular and pericardial complications. METHODS: Rapid left ventricular pacing was provided via the back-up 0.035″ guidewire. The cathode of an external pacemaker was placed on the tip of the 0.035″ wire and the anode on a needle inserted into the groin. Insulation was ensured by the balloon or TAVI catheter. RESULTS: 38 BAV and 87 TAVI procedures were performed in 113 consecutive patients in three centers with one for one pacing (160-200 bpm) in all patients. A significant reduction in blood pressure was achieved with a mean systolic pressure of 44 mm Hg during stimulation. Mean procedural time was 49.7 ± 31 min for BAV and 68.7 ± 30.9 for TAVI. A temporary venous pacemaker was required in 12 patients; only 12% of TAVI patients had a femoral central venous catheter. Femoral venous puncture was not performed in BAV patients. No venous vascular complications were observed. One case of successfully treated tamponade (0.8%) occurred 8 hr post procedure. In-hospital mortality rates were 4.6% and 2.6% in the TAVI and BAV groups, respectively. CONCLUSIONS: Use of the LV guidewire for rapid pacing during BAV and TAVI was shown to be simple, reproducible, and prevented complications associated with RV temporary leads thus potentially simplifying TAVI and enhancing its safety. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Valvuloplastia con Balón/métodos , Cateterismo Cardíaco/métodos , Ventrículos Cardíacos/fisiopatología , Marcapaso Artificial , Complicaciones Posoperatorias/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica , Ecocardiografía , Electrocardiografía , Femenino , Estudios de Seguimiento , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Periodo Intraoperatorio , Masculino , Complicaciones Posoperatorias/epidemiología , Estudios Prospectivos
5.
EuroIntervention ; 20(17): e1076-e1085, 2024 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-39219361

RESUMEN

BACKGROUND: Large datasets of transcatheter aortic valve implantation (TAVI) for pure aortic valve regurgitation (PAVR) are scarce. AIMS: We aimed to report procedural safety and long-term clinical events (CE) in a contemporary cohort of PAVR patients treated with new-generation devices (NGD). METHODS: Patients with grade III/IV PAVR enrolled in the FRANCE-TAVI Registry were selected. The primary safety endpoint was technical success (TS) according to Valve Academic Research Consortium 3 criteria. The co-primary endpoint was defined as a composite of mortality, heart failure hospitalisation and valve reintervention at last follow-up. RESULTS: From 2015 to 2021, 227 individuals (64.3% males, median age 81.0 [interquartile range {IQR} 73.5-85.0] years, with EuroSCORE II 6.0% [IQR 4.0-10.9]) from 41 centres underwent TAVI with NGD, using either self-expanding (55.1%) or balloon-expandable valves (44.9%; p=0.50). TS was 85.5%, with a non-significant trend towards increased TS in high-volume activity centres. A second valve implantation (SVI) was needed in 8.8% of patients, independent of valve type (p=0.82). Device size was ≥29 mm in 73.0% of patients, post-procedure grade ≥III residual aortic regurgitation was rare (1.2%), and the permanent pacemaker implantation (PPI) rate was 36.0%. At 30 days, the incidences of mortality and reintervention were 8.4% and 3.5%, respectively. The co-primary endpoint reached 41.6% (IQR 34.4-49.6) at 1 year, increased up to 61.8% (IQR 52.4-71.2) at 4 years, and was independently predicted by TS, with a hazard ratio of 0.45 (95% confidence interval: 0.27-0.76); p=0.003. CONCLUSIONS: TAVI with NGD in PAVR patients is efficient and reasonably safe. Preventing the need for an SVI embodies the major technical challenge. Larger implanted valves may have limited this complication, outweighing the increased risk of PPI. Despite successful TAVI, PAVR patients experience frequent CE at long-term follow-up.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Insuficiencia de la Válvula Aórtica/cirugía , Masculino , Femenino , Anciano , Anciano de 80 o más Años , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Factores de Riesgo , Francia
6.
Arch Cardiovasc Dis ; 115(10): 521-528, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36115768

RESUMEN

BACKGROUND: Management of mitral regurgitation recurrence after failed surgical valve repair with ring implantation is controversial. AIM: To describe the French experience regarding midterm safety and efficacy of transcatheter edge-to-edge mitral valve repair (TEER) in patients with failed surgical valve repair with ring implantation. METHODS: The "Clip-in-Ring" registry is a multicentre registry conducted in 11 centres in France, approved by local institutional review boards, of consecutive TEER following surgical valve repair with ring implantation. Outcomes were Mitral Valve Academic Research Consortium (MVARC) technical success, modified 30-day device and procedural success (where 10mmHg is considered as a cut-off for significant mitral stenosis) and MVARC complications. RESULTS: Twenty-three patients were studied: mean age, 69±10years; male sex, 74%; EuroSCORE II, 16±17; left ventricular ejection fraction, 53±12%; mitral regurgitation grade 3+/4+, 17%/78%; New York Heart Association class III/IV, 47%/22%; median surgery to TEER delay, 23 (6-94) months. Technical success was 100%. At discharge, residual mitral regurgitation grade was≤2+ in 87% and median transmitral gradient was 4 (3-5) mmHg. Thirty-day modified MVARC device and procedural success was 82%: four patients (17%) had residual mitral regurgitation grade>2+, including two patients who needed complementary surgery. No patient had a 30-day transmitral gradient>7mmHg. No patient died or had a stroke or any life-threatening complications. One patient presented a vascular access complication requiring transfusion. No other MVARC-2 adverse event was reported. CONCLUSIONS: TEER in patients with failed mitral ring is feasible and safe. Further studies should delineate its exact role in the therapeutic armamentarium for this medical issue.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Masculino , Persona de Mediana Edad , Anciano , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Volumen Sistólico , Función Ventricular Izquierda , Resultado del Tratamiento , Instrumentos Quirúrgicos , Sistema de Registros , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos
7.
J Clin Med ; 12(1)2022 Dec 23.
Artículo en Inglés | MEDLINE | ID: mdl-36614920

RESUMEN

Prosthetic paravalvular leaks (PVLs) are associated with congestive heart failure and hemolysis. Surgical PVL closure carries high risks. Transcatheter implantation of occluding devices in PVL is a lower risk but challenging procedure. Of the available devices, only two have been specifically approved in Europe for transcatheter PVL closure (tPVLc): the Occlutech® Paravalvular Leak Device (PLD) and Amplatzer™ ParaValvular Plug 3 (AVP 3). Here, we review the various tools and devices used for tPVLc, based on three observational registries including 748 tPVLc procedures performed in 2005-2021 at 33 centres in 11 countries. In this case, 12 registry investigators with over 20 tPVLc procedures each described their practical tips and tricks regarding imaging, approaches, delivery systems, and devices. They considered three-dimensional echocardiography to be the cornerstone of PVL assessment and procedure guidance. Anterograde trans-septal mitral valve and retrograde aortic approaches were used in most centres, although some investigators preferred the transapical approach. Hydrophilic-coated low-profile sheaths were used most often for device deployment. The AVP 3 and PLD devices were chosen for 89.0% of procedures. Further advances in design and materials are awaited. These complex procedures require considerable expertise, and experience accumulated over a decade has no doubt contributed to improve practices.

8.
Circ Cardiovasc Interv ; 15(10): e012193, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36256693

RESUMEN

BACKGROUND: Transcatheter closure of a symptomatic prosthetic paravalvular leak (PVL) is feasible, but there is presently no conclusive evidence to show consistent efficacy. We aimed to identify predictors of clinical success after transcatheter PVL closure. METHODS: Consecutive patients referred to 24 European centers for transcatheter PVL closure in 2017 to 2019 were included in a prospective registry (Fermeture de Fuite ParaProthétique, FFPP). Clinical success was absence of any of the following within 1 month: re-admission for heart failure, blood transfusion, open-heart valvular surgery, and death. RESULTS: We included 216 symptomatic patients, who underwent 238 percutaneous PVL closure procedures on the mitral (64.3%), aortic (34.0%), or tricuspid (1.7%) valve. Symptoms were heart failure, hemolytic anemia, or both in 48.9%, 7.8%, and 43.3% of patients, respectively. One, 2, and 3 leaks were treated during the same procedure in 69.6%, 26.6%, and 3.8% of patients, respectively. The PVL was pinpoint or involved 1/8 or 1/4 of the valve circumference in 18.6%, 52.4%, and 28.1% of cases, respectively. The most frequently used devices were the Vascular Plug 3, Ventricular Septal Defect Occluder, Vascular Plug 2, and Paravalvular Leak Device (45.0%, 16.6%, 14.2%, and 13.6% of cases, respectively). Successful device(s) implantation with leak reduction to ≤grade 2 was obtained in 85.0% of mitral and 91.4% of aortic procedures, respectively (P=0.164); with major periprocedural adverse event rates of 3.3% and 1.2%, respectively (P=0.371); and clinical success rates of 70.3% and 88.0%, respectively (P=0.004). By multivariate analysis, technical failure, mechanical valve, and hemolytic anemia were independently associated with absence of clinical success (odds ratios [95% CIs], 7.7 [2.0-25.0]; P=0.002; 3.6 [1.1-11.1]; P=0.036; and 3.7 [1.2-11.9]; P=0.025; respectively). CONCLUSIONS: Transcatheter PVL closure is efficient and safe in symptomatic patients but is associated with a lower clinical success rate in patients with hemolysis and/or a mechanical valve. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifiers: NCT05089136.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Sistema de Registros , Insuficiencia Cardíaca/etiología , Cateterismo Cardíaco , Falla de Prótesis
9.
Am J Cardiol ; 144: 118-124, 2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-33383007

RESUMEN

Patients with symptomatic aortic stenosis are often treated with a surgical valve replacement. Surgical bioprosthetic valves degenerate over time and therefore may necessitate a redo surgery. This analysis reports the 2-year clinical outcomes of the Valve-in-Valve study, which evaluated transcatheter aortic valve implantation using the CoreValve and Evolut R devices in patients with degenerated surgical aortic bioprostheses at high risk for surgery. The prospective Valve-in-Valve study enrolled 202 eligible patients with failing surgical aortic bioprostheses due to stenosis, regurgitation, or a combination of both. The Evolut R bioprosthesis was used in 90.5% of valve-in-valve transcatheter aortic valve implantation cases. Two-year all-cause and cardiovascular mortality rates were 16.5% and 11.1%, respectively. Other clinical events included stroke (7.9%), disabling stroke (1.7%), and new pacemaker implantation (10.1%). The 2-year all-cause mortality rate was significantly higher in patients with discharge mean gradients ≥20 mmHg vs. those with lower mean gradients (21.0% vs 7.6%, p = 0.025). Discharge mean gradients ≥20 mm Hg were associated with smaller surgical bioprostheses (OR, 7.2 [95% CI 2.3 to 22.1]. In patients with failing surgical aortic bioprostheses, valve-in-valve treatment using a supra-annular self-expanding bioprosthesis provides significant functional improvements with acceptable rates of complications, especially if a postprocedural mean gradient of <20 mmHg can be achieved.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Vigilancia de Productos Comercializados , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Reoperación , Reemplazo de la Válvula Aórtica Transcatéter/métodos
10.
J Am Coll Cardiol ; 77(18): 2263-2273, 2021 05 11.
Artículo en Inglés | MEDLINE | ID: mdl-33958122

RESUMEN

BACKGROUND: Permanent pacemaker implantation (PPI) remains one of the main drawbacks of transcatheter aortic valve replacement (TAVR), but scarce data exist on PPI after valve-in-valve (ViV) TAVR, particularly with the use of newer-generation transcatheter heart valves (THVs). OBJECTIVES: The goal of this study was to determine the incidence, factors associated with, and clinical impact of PPI in a large series of ViV-TAVR procedures. METHODS: Data were obtained from the multicenter VIVID Registry and included the main baseline and procedural characteristics, in-hospital and late (median follow-up: 13 months [interquartile range: 3 to 41 months]) outcomes analyzed according to the need of periprocedural PPI. All THVs except CoreValve, Cribier-Edwards, Sapien, and Sapien XT were considered to be new-generation THVs. RESULTS: A total of 1,987 patients without prior PPI undergoing ViV-TAVR from 2007 to 2020 were included. Of these, 128 patients (6.4%) had PPI after TAVR, with a significant decrease in the incidence of PPI with the use of new-generation THVs (4.7% vs. 7.4%; p = 0.017), mainly related to a reduced PPI rate with the Evolut R/Pro versus CoreValve (3.7% vs. 9.0%; p = 0.002). There were no significant differences in PPI rates between newer-generation balloon- and self-expanding THVs (6.1% vs. 3.9%; p = 0.18). In the multivariable analysis, older age (odds ratio [OR]: 1.05 for each increase of 1 year; 95% confidence interval [CI]: 1.02 to 1.07; p = 0.001), larger THV size (OR: 1.10; 95% CI: 1.01 to 1.20; p = 0.02), and previous right bundle branch block (OR: 2.04; 95% CI: 1.00 to 4.17; p = 0.05) were associated with an increased risk of PPI. There were no differences in 30-day mortality between the PPI (4.7%) and no-PPI (2.7%) groups (p = 0.19), but PPI patients exhibited a trend toward higher mortality risk at follow-up (hazard ratio: 1.39; 95% CI: 1.02 to 1.91; p = 0.04; p = 0.08 after adjusting for age differences between groups). CONCLUSIONS: In a contemporary large series of ViV-TAVR patients, the rate of periprocedural PPI was relatively low, and its incidence decreased with the use of new-generation THV systems. PPI following ViV-TAVR was associated with a trend toward increased mortality at follow-up.


Asunto(s)
Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Implantación de Prótesis , Sistema de Registros
11.
JACC Cardiovasc Interv ; 12(10): 923-932, 2019 05 27.
Artículo en Inglés | MEDLINE | ID: mdl-31122349

RESUMEN

OBJECTIVES: The VIVA (Valve in Valve) trial was designed to systematically and prospectively collect data regarding the use of transcatheter aortic valve replacement in patients with failing surgical aortic bioprostheses at high-risk for reoperation. BACKGROUND: Surgical aortic valve replacement has been the standard of care in symptomatic patients with aortic valve disease. However, bioprosthetic valves degenerate over time, requiring redo surgery. METHODS: VIVA is an international, observational, single-arm, postmarket study conducted at 23 sites that enrolled 202 patients with symptomatic degeneration of an aortic bioprosthesis eligible for elective treatment with a CoreValve or Evolut R self-expanding transcatheter aortic valve. RESULTS: Patients were elderly (mean age 79.9 years), 47.5% were men, and they had a mean Society of Thoracic Surgeons score of 6.6%. Although 41.8% of patients had surgical bioprostheses with labeled size ≤21 mm, valve hemodynamic parameters were markedly improved from baseline (mean aortic valve gradient 35.0 ± 16.3 mm Hg) to discharge (17.5 ± 8.6 mm Hg) and were sustained at 1 year (15.5 ± 7.5 mm Hg). At 1 year, total aortic regurgitation greater than mild was measured in 1.1% of patients. Clinical outcomes at 30 days demonstrated low mortality (2.5%), no disabling strokes, a 0.5% rate of acute kidney injury, and an 8.0% rate of new pacemaker implantation. At 1 year, the mortality rate remained low (8.8%), with 1 disabling stroke (0.6%). Five patients (2.5%) experienced coronary artery obstructions, 3 during and 1 immediately after the procedure and 1 several months later. CONCLUSIONS: Degenerated surgical bioprostheses can be safely treated with the CoreValve or Evolut R platform using the catheter-based valve-in-valve procedure. Excellent 1-year clinical and hemodynamic outcomes were achieved in this real-world patient population. (CoreValve VIVA Study Evaluation of the Clinical Outcomes of CoreValve in Degenerative Surgical Aortic Bioprosthesis; NCT02209298).


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Europa (Continente) , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemodinámica , Humanos , Israel , Masculino , Complicaciones Posoperatorias/etiología , Vigilancia de Productos Comercializados , Diseño de Prótesis , Recuperación de la Función , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Índices de Gravedad del Trauma , Resultado del Tratamiento
13.
Arch Cardiovasc Dis ; 111(6-7): 421-431, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29937207

RESUMEN

BACKGROUND: Percutaneous paravalvular leak (PVL) closure has emerged as a palliative alternative to surgical management in selected high-risk patients. Percutaneous procedures are challenging, especially for mitral PVL. Accurate imaging of the morphologies of the defects is mandatory, together with precise guidance in the catheterization laboratory to enhance success rates. AIMS: To describe imaging modalities used in clinical practice to guide percutaneous PVL closure and assess the potential of new imaging tools. METHODS: Data from the 'Fermeture de Fuite paraprothétique' (FFPP) register were used. The FFPP register is an international multi-institutional collaborative register started in 2017 with a retrospective and a prospective part. A descriptive analysis of multimodality imaging used to guide PVL closure in clinical practice was performed. RESULTS: Data from 173 procedures performed in 19 centres from three countries (France, Belgium and Poland) were collected, which included eight cases of PVL following transcatheter valve replacement. Transoesophageal echocardiography was used in 167 cases (96.5%) and 3D echocardiography in 87.4% of cases. In one case, 3D-echocardiography was fused with fluoroscopy images in real time using echonavigator software. Details about multimodality imaging were available from a sample of 31 patients. Cardiac computed tomography (CT) was performed before 10 of the procedures. In one case, fusion between preprocedural cardiac CT angiography data and fluoroscopy data was used. In two cases, a 3D model of the valve with PVL was printed. CONCLUSION: Echocardiography, particularly the 3D mode, is the cornerstone of PVL imaging. Other imaging modalities, such as cardiac CT and cardiac magnetic resonance imaging, may be of complementary interest. New techniques such as imaging fusion and printing may further facilitate the percutaneous approach of PVLs.


Asunto(s)
Insuficiencia de la Válvula Aórtica/terapia , Válvula Aórtica/cirugía , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Mitral/terapia , Válvula Mitral/cirugía , Imagen Multimodal/métodos , Radiografía Intervencional/métodos , Ultrasonografía Intervencional/métodos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/efectos adversos , Angiografía por Tomografía Computarizada , Ecocardiografía Doppler en Color , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Europa (Continente) , Femenino , Fluoroscopía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/fisiopatología , Valor Predictivo de las Pruebas , Impresión Tridimensional , Estudios Prospectivos , Estudios Retrospectivos , Resultado del Tratamiento
14.
Heart ; 104(10): 828-834, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29352008

RESUMEN

OBJECTIVE: We aimed to analyse the incidence of prosthesis-patient mismatch (PPM) and elevated gradients after aortic valve in valve (ViV), and to evaluate predictors and associations with clinical outcomes of this adverse event. METHODS: A total of 910 aortic ViV patients were investigated. Elevated residual gradients were defined as ≥20 mm Hg. PPM was identified based on the indexed effective orifice area (EOA), measured by echocardiography, and patient body mass index (BMI). Moderate and severe PPM (cases) were defined by European Association of Cardiovascular Imaging (EACVI) criteria and compared with patients without PPM (controls). RESULTS: Moderate or greater PPM was found in 61% of the patients, and severe in 24.6%. Elevated residual gradients were found in 27.9%. Independent risk factors for the occurrence of lower indexed EOA and therefore severe PPM were higher gradients of the failed bioprosthesis at baseline (unstandardised beta -0.023; 95% CI -0.032 to -0.014; P<0.001), a stented (vs a stentless) surgical bioprosthesis (unstandardised beta -0.11; 95% CI -0.161 to -0.071; P<0.001), higher BMI (unstandardised beta -0.01; 95% CI -0.013 to -0.007; P<0.001) and implantation of a SAPIEN/SAPIEN XT/SAPIEN 3 transcatheter device (unstandardised beta -0.064; 95% CI -0.095 to -0.032; P<0.001). Neither severe PPM nor elevated gradients had an association with VARC II-defined outcomes or 1-year survival (90.9% severe vs 91.5% moderate vs 89.3% none, P=0.44). CONCLUSIONS: Severe PPM and elevated gradients after aortic ViV are very common but were not associated with short-term survival and clinical outcomes. The long-term effect of poor post-ViV haemodynamics on clinical outcomes requires further evaluation.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Bioprótesis/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Hemodinámica , Complicaciones Posoperatorias , Reoperación , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Índice de Masa Corporal , Ecocardiografía/métodos , Femenino , Humanos , Incidencia , Masculino , Evaluación de Resultado en la Atención de Salud , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/fisiopatología , Complicaciones Posoperatorias/cirugía , Valor Predictivo de las Pruebas , Diseño de Prótesis , Falla de Prótesis , Reoperación/instrumentación , Reoperación/métodos , Medición de Riesgo , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos
15.
J Am Coll Cardiol ; 70(1): 42-55, 2017 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-28662806

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is standard therapy for patients with severe aortic stenosis who are at high surgical risk. However, national data regarding procedural characteristics and clinical outcomes over time are limited. OBJECTIVES: The aim of this study was to assess nationwide performance trends and clinical outcomes of TAVR during a 6-year period. METHODS: TAVRs performed in 48 centers across France between January 2013 and December 2015 were prospectively included in the FRANCE TAVI (French Transcatheter Aortic Valve Implantation) registry. Findings were further compared with those reported from the FRANCE 2 (French Aortic National CoreValve and Edwards 2) registry, which captured all TAVRs performed from January 2010 to January 2012 across 34 centers. RESULTS: A total of 12,804 patients from FRANCE TAVI and 4,165 patients from FRANCE 2 were included in this analysis. The median age of patients was 84.6 years, and 49.7% were men. FRANCE TAVI participants were older but at lower surgical risk (median logistic European System for Cardiac Operative Risk Evaluation [EuroSCORE]: 15.0% vs. 18.4%; p < 0.001). More than 80% of patients in FRANCE TAVI underwent transfemoral TAVR. Transesophageal echocardiography guidance decreased from 60.7% to 32.3% of cases, whereas more recent procedures were increasingly performed in hybrid operating rooms (15.8% vs. 35.7%). Rates of Valve Academic Research Consortium-defined device success increased from 95.3% in FRANCE 2 to 96.8% in FRANCE TAVI (p < 0.001). In-hospital and 30-day mortality rates were 4.4% and 5.4%, respectively, in FRANCE TAVI compared with 8.2% and 10.1%, respectively, in FRANCE 2 (p < 0.001 for both). Stroke and potentially life-threatening complications, such as annulus rupture or aortic dissection, remained stable over time, whereas rates of cardiac tamponade and pacemaker implantation significantly increased. CONCLUSIONS: The FRANCE TAVI registry provided reassuring data regarding trends in TAVR performance in an all-comers population on a national scale. Nonetheless, given that TAVR indications are likely to expand to patients at lower surgical risk, concerns remain regarding potentially life-threatening complications and pacemaker implantation. (Registry of Aortic Valve Bioprostheses Established by Catheter [FRANCE TAVI]; NCT01777828).


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter/tendencias , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/epidemiología , Ecocardiografía Transesofágica , Femenino , Estudios de Seguimiento , Francia/epidemiología , Humanos , Incidencia , Masculino , Pronóstico , Estudios Prospectivos , Tasa de Supervivencia/tendencias , Factores de Tiempo
16.
JACC Cardiovasc Interv ; 10(12): 1202-1210, 2017 06 26.
Artículo en Inglés | MEDLINE | ID: mdl-28641840

RESUMEN

OBJECTIVES: The aim of this study was to test the hypothesis that 6-month dual antiplatelet therapy (DAPT) is noninferior to 24-month DAPT in aspirin-sensitive patients. BACKGROUND: The ITALIC (Is There a Life for DES After Discontinuation of Clopidogrel) trial showed that rates of bleeding and thrombotic events at 1 year were much the same with 6 versus 12 months of DAPT after percutaneous coronary intervention with second-generation drug-eluting stents. In this report, 2-year follow-up is presented. METHODS: In a multicenter randomized study, patients with confirmed nonresistance to aspirin undergoing drug-eluting stent implantation were allocated to 6 or 24 months of DAPT. The primary endpoint was a composite of death, myocardial infarction, urgent target vessel revascularization, stroke, and major bleeding at 12 months post-percutaneous coronary intervention. The secondary endpoints comprised the same composite endpoint at 24 months and each individual component. RESULTS: Overall, 2,031 patients from 70 centers were screened; 926 were randomized to 6-month and 924 to 24-month DAPT. Noninferiority was demonstrated for 6- versus 12-month DAPT, with an absolute risk difference of 0.11% (95% confidence interval: -1.04% to 1.26%; p = 0.0002). At 2 years, the composite endpoint was unchanged, at 3.5% for 6 months and 3.7% for 24 months (p = 0.79), and rates of myocardial infarction (1.3% vs. 1.0%; p = 0.51), stroke (0.6% vs. 0.8%; p = 0.77), and target vessel revascularization (1.0% vs. 0.3%; p = 0.09) were likewise similar. There was a trend toward higher mortality with longer DAPT (2.2% vs. 1.2%; p = 0.11). Four patients (0.4%) in the 24-month group and none in the 6-month group had major bleeding. CONCLUSIONS: Two-year outcomes in the ITALIC trial confirmed the 1-year results and showed that patients receiving 6-month DAPT after percutaneous coronary intervention with second-generation drug-eluting stent have similar outcomes to those receiving 24-month DAPT.


Asunto(s)
Aspirina/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Inhibidores de Agregación Plaquetaria/administración & dosificación , Ticlopidina/análogos & derivados , Anciano , Aspirina/efectos adversos , Clopidogrel , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/etiología , Esquema de Medicación , Quimioterapia Combinada , Femenino , Francia , Hemorragia/inducido químicamente , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Inhibidores de Agregación Plaquetaria/efectos adversos , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Ticlopidina/administración & dosificación , Ticlopidina/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
17.
Artículo en Inglés | MEDLINE | ID: mdl-27301396

RESUMEN

BACKGROUND: Transcatheter valve implantation inside failed bioprosthetic surgical valves (valve-in-valve [ViV]) may offer an advantage over reoperation. Supra-annular transcatheter valve position may be advantageous in achieving better hemodynamics after ViV. Our objective was to define targets for implantation that would improve hemodynamics after ViV. METHODS AND RESULTS: Cases from the Valve-in-Valve International Data (VIVID) registry were analyzed using centralized core laboratory assessment blinded to clinical events. Multivariate analysis was performed to identify independent predictors of elevated postprocedural gradients (mean ≥20 mm Hg). Optimal implantation depths were defined by receiver operating characteristic curve. A total of 292 consecutive patients (age, 78.9±8.7 years; 60.3% male; 157 CoreValve Evolut and 135 Sapien XT) were evaluated. High implantation was associated with significantly lower rates of elevated gradients in comparison with low implantation (CoreValve Evolut, 15% versus 34.2%; P=0.03 and Sapien XT, 18.5% versus 43.5%; P=0.03, respectively). Optimal implantation depths were defined: CoreValve Evolut, 0 to 5 mm; Sapien XT, 0 to 2 mm (0-10% frame height); sensitivities, 91.3% and 88.5%, respectively. The strongest independent correlate for elevated gradients after ViV was device position (high: odds ratio, 0.22; confidence interval, 0.1-0.52; P=0.001), in addition to type of device used (CoreValve Evolut: odds ratio, 0.5; confidence interval, 0.28-0.88; P=0.02) and surgical valve mechanism of failure (stenosis/mixed baseline failure: odds ratio, 3.12; confidence interval, 1.51-6.45; P=0.002). CONCLUSIONS: High implantation inside failed bioprosthetic valves is a strong independent correlate of lower postprocedural gradients in both self- and balloon-expandable transcatheter valves. These clinical evaluations support specific implantation targets to optimize hemodynamics after ViV.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Hemodinámica , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Valvuloplastia con Balón , Distribución de Chi-Cuadrado , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Análisis Multivariante , Oportunidad Relativa , Diseño de Prótesis , Recuperación de la Función , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
18.
J Am Coll Cardiol ; 65(8): 777-786, 2015 Mar 03.
Artículo en Inglés | MEDLINE | ID: mdl-25461690

RESUMEN

BACKGROUND: The currently recommended duration of dual antiplatelet therapy (DAPT) in drug-eluting stent (DES) recipients is 12 months to reduce the risk of late stent thrombosis, particularly in those with acute coronary syndrome (ACS). OBJECTIVES: This study hypothesized that antiplatelet treatment with DAPT for 6 months may be noninferior to 24-month DAPT in aspirin-sensitive patients. METHODS: A multicenter, randomized study assigned patients undergoing implantation of everolimus-eluting stents with confirmed nonresistance to aspirin to receive 6- or 24-month DAPT. The primary endpoint was a composite of death, myocardial infarction, urgent target vessel revascularization, stroke, and major bleeding at 12 months post-stenting. RESULTS: A total of 2,031 patients were enrolled in 70 European and Middle Eastern centers. The trial was prematurely terminated due to recruitment problems, leaving 941 patients randomized to 24-month DAPT and 953 to 6-month DAPT. The 2 treatment groups had similar baseline and procedural characteristics. There was no significant difference in the primary endpoint (24-month: 1.5% vs. 6-month: 1.6%; p = 0.85). Noninferiority was demonstrated for 6- versus 24-month DAPT, with an absolute risk difference of 0.11% (95% confidence interval: -1.04% to 1.26%; p for noninferiority = 0.0002). There were no significant differences in stent thrombosis or bleeding complications. In the 792 (44%) high-risk patients with ACS, primary and secondary endpoints did not significantly differ (hazard ratio: 1.7 [95% confidence interval: 0.519 to 6.057; p = 0.361]). CONCLUSIONS: Rates of bleeding and thrombotic events were not significantly different according to 6- versus 24-month DAPT after PCI with new-generation DES in good aspirin responders. (Is There A LIfe for DES After Discontinuation of Clopidogrel [ITALICplus]; NCT01476020).


Asunto(s)
Aspirina , Enfermedad de la Arteria Coronaria/terapia , Reestenosis Coronaria , Stents Liberadores de Fármacos/efectos adversos , Hemorragia , Intervención Coronaria Percutánea , Ticlopidina/análogos & derivados , Anciano , Aspirina/administración & dosificación , Aspirina/efectos adversos , Clopidogrel , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/fisiopatología , Reestenosis Coronaria/diagnóstico , Reestenosis Coronaria/etiología , Reestenosis Coronaria/prevención & control , Vasos Coronarios/patología , Vasos Coronarios/cirugía , Terminación Anticipada de los Ensayos Clínicos , Europa (Continente) , Everolimus , Femenino , Hemorragia/etiología , Hemorragia/prevención & control , Humanos , Inmunosupresores/uso terapéutico , Masculino , Persona de Mediana Edad , Medio Oriente , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Inhibidores de Agregación Plaquetaria/administración & dosificación , Inhibidores de Agregación Plaquetaria/efectos adversos , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/prevención & control , Sirolimus/análogos & derivados , Sirolimus/uso terapéutico , Ticlopidina/administración & dosificación , Ticlopidina/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
19.
J Am Coll Cardiol ; 61(15): 1577-84, 2013 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-23433565

RESUMEN

OBJECTIVES: This study sought to collect data and evaluate the anecdotal use of transcatheter aortic valve implantation (TAVI) in pure native aortic valve regurgitation (NAVR) for patients who were deemed surgically inoperable BACKGROUND: Data and experience with TAVI in the treatment of patients with pure severe NAVR are limited. METHODS: Data on baseline patient characteristics, device and procedure parameters, echocardiographic parameters, and outcomes up to July 2012 were collected retrospectively from 14 centers that have performed TAVI for NAVR. RESULTS: A total of 43 patients underwent TAVI with the CoreValve prosthesis (Medtronic, Minneapolis, Minnesota) at 14 centers (mean age, 75.3 ± 8.8 years; 53% female; mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation), 26.9 ± 17.9%; and mean Society of Thoracic Surgeons score, 10.2 ± 5.3%). All patients had severe NAVR on echocardiography without aortic stenosis and 17 patients (39.5%) had the degree of aortic valvular calcification documented on CT or echocardiography. Vascular access was transfemoral (n = 35), subclavian (n = 4), direct aortic (n = 3), and carotid (n = 1). Implantation of a TAVI was performed in 42 patients (97.7%), and 8 patients (18.6%) required a second valve during the index procedure for residual aortic regurgitation. In all patients requiring second valves, valvular calcification was absent (p = 0.014). Post-procedure aortic regurgitation grade I or lower was present in 34 patients (79.1%). At 30 days, the major stroke incidence was 4.7%, and the all-cause mortality rate was 9.3%. At 12 months, the all-cause mortality rate was 21.4% (6 of 28 patients). CONCLUSIONS: This registry analysis demonstrates the feasibility and potential procedure difficulties when using TAVI for severe NAVR. Acceptable results may be achieved in carefully selected patients who are deemed too high risk for conventional surgery, but the possibility of requiring 2 valves and leaving residual aortic regurgitation remain important considerations.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Válvula Aórtica/cirugía , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas , Complicaciones Posoperatorias/epidemiología , Accidente Cerebrovascular , Anciano , Anciano de 80 o más Años , Válvula Aórtica/patología , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/cirugía , Calcinosis , Ecocardiografía/métodos , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/estadística & datos numéricos , Humanos , Cuidados Intraoperatorios/métodos , Cuidados Intraoperatorios/estadística & datos numéricos , Masculino , Diseño de Prótesis , Sistema de Registros/estadística & datos numéricos , Estudios Retrospectivos , Ajuste de Riesgo , Índice de Severidad de la Enfermedad , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Tasa de Supervivencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA