1.
Lasers Surg Med ; 56(2): 142-149, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38247054

RESUMEN

BACKGROUND AND OBJECTIVES: Fractional radiofrequency devices have been demonstrated to improve skin texture, such as smoothness, rhytides, brightness, and atrophic acne scars, by increasing dermal thickness, dermal collagen content, and dermal fibrillin content. The objective of the study is to assess the efficacy and adverse effects of this device on Asian patients of skin type III and IV with skin textural changes. MATERIALS AND METHODS: The study was designed as a prospective, open-labeled single-arm study, which was conducted with 20 Chinese patients aged 21-60 years and having irregularities in their skin texture, rhytides, and acne scars. The patients received six treatments at intervals of 4 weeks. Treatment was initiated with the maximum energy tolerated, which was then adjusted during the course of treatment if the patients felt excessive discomfort. A total of two passes were delivered in each session. Physician assessment results and standardized photographs were collected at the baseline, after all treatment visits, and at 1, 2, and 6 months after the final treatment visit. RESULTS: A total of 17 patients completed the study according to the established protocol. At the 6-month follow-up, 71% of patients were satisfied and 24% of patients were very satisfied with the received treatments, and the treatment physician reported varying degrees of improvement based on the global assessment scale in 60% of the subjects. While the anticipated side effects, such as erythema, edema, pinpoint bleeding, scab formation, and flare of acne, were noted in the patients, no serious adverse effects occurred. CONCLUSION: The use of fractional radiofrequency improves skin texture and is safe for use in Asian patients of skin type III and IV. No long-term serious adverse effects were noted.


Asunto(s)
Acné Vulgar , Cicatriz , Humanos , Acné Vulgar/radioterapia , Pueblo Asiatico , Cicatriz/terapia , Estudios Prospectivos , Piel/patología , Resultado del Tratamiento , Adulto Joven , Adulto , Persona de Mediana Edad
2.
Lasers Surg Med ; 2024 Jun 23.
Artículo en Inglés | MEDLINE | ID: mdl-38922979

RESUMEN

OBJECTIVE: Our study aimed to evaluate the efficacy of this novel dermal cooling system (DCS) in reducing pigmentation in benign pigmented lesions in Asian patients and its potential side effects. METHODS: It was a prospective open-label single-center study. Asian patients, with the presence of benign pigmented lesions mainly including lentigines, melasma, nevus spilus, ephelides, café au lait, and seborrheic keratosis were recruited for a novel DCS. The DCS provided localized cooling of the epidermal layer below freezing but was less intense than cryotherapy. Each patient received DCS at Week 0 and repeated at 4-week intervals up to 10 sessions. Global aesthetic improvement scores (GAIS) by blinded physicians and subjects were recorded at 2, 6, and 12 months posttreatment follow-up. RESULTS: Eighty-one patients were recruited with a total of 305 sessions performed and 1716 lesion sites treated. At 2-month posttreatment, 76.5% and 58.6% treatment sites showed obvious to marked improvement respectively and the improvement sustained at 6 and 12 months. Only minor adverse events were reported. Erythema and edema were the most commonly anticipated effects immediately after treatment. The pain was minimal. Postinflammatory hyperpigmentation was only reported in 2.2% (38/1716) treated sites. CONCLUSION: To our knowledge, this study was the first study to demonstrate that this novel DCS was an effective, safe, and well-tolerated treatment for benign pigmented lesions in Asians.

3.
Lasers Surg Med ; 53(1): 9-49, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32282094

RESUMEN

BACKGROUND AND OBJECTIVES: The use of picosecond laser in dermatology was originally focused on optimizing the removal of unwanted tattoos. Subsequent advances in this technology have broadened its clinical indications to include treatment of benign pigmented lesions, photodamage, melasma, and scar revision. In this systematic review, evidence-based recommendations are developed for the use of picosecond laser in dermatology. STUDY DESIGN/MATERIALS AND METHODS: A comprehensive search of the English language literature was performed up to and including November 2019. Relevant citations were individually evaluated, synthesized, and categorized based on the Level of Evidence. With the addition of the authors' combined clinical experience, clinical recommendations were developed. RESULTS: After application of inclusion and exclusion criteria, a total of 77 unique studies were evaluated. Treatment of benign pigmented lesions was associated with level I-IV evidence; rejuvenation was associated with level II evidence; melasma was associated with level II evidence; scar revision was associated with level II-III evidence; tattoo removal was associated with level I evidence. CONCLUSION: Picosecond laser is a safe and effective treatment modality for an increasing range of dermatologic indications. Further development of this technology is warranted. Lasers Surg. Med. © 2020 Wiley Periodicals, Inc.


Asunto(s)
Dermatología , Láseres de Estado Sólido , Melanosis , Tatuaje , Humanos , Láseres de Estado Sólido/uso terapéutico , Rejuvenecimiento
4.
Lasers Surg Med ; 53(8): 1032-1042, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33544930

RESUMEN

BACKGROUND AND OBJECTIVES: Facial melasma is a disfiguring pigmentation and occurs frequently with aging skin. Topical treatment alone was often suboptimal. A recent study showed that fractional picosecond laser has promising result in benign pigmentary lesions. This study aims to investigate the efficacy and safety of 1064 nm picosecond laser in treatment of facial melasma and skin rejuvenation in Asian skin. STUDY DESIGN/MATERIALS AND METHODS: Patients of Asian descent seeking treatment for facial melasma and skin rejuvenation were screened and recruited. Each patient received up to nine laser treatments at 4-6 weeks intervals with a fractionated nonablative 1064 nm picosecond laser. Baseline and posttreatment modified Melasma Area Severity Index (mMASI) and Global Aesthetic Improvement Scale (IGAS) were assessed by blinded investigators based on the clinical photographs. Subject overall satisfaction was assessed by the questionnaires after treatment. All adverse events were documented. RESULTS: Twenty patients were recruited with a median age of 52.7 ± 8.2 years. Three subjects had Fitzpatrick skin type III and 17 had skin type IV. All subjects received nine laser sessions. Over 70% of patients were satisfied with the treatment outcomes. There was a statistically significant improvement in mMASI which reduced from 10.8 at baseline to 2.7 and 3.6 at 6 and 12 weeks post-treatment, respectively (both P < 0.01). For skin rejuvenation, 70% reported at least a moderate improvement at 6 weeks of post-treatment. No major side-effect was reported. Erythema was the most frequent transient response, while some reported edema (1.1%). Both resolved spontaneously. None reported hypo- or hyperpigmentation after treatment. The overall mean pain scare (VAS) was 1.92. CONCLUSION: Fractionated non-ablative 1064 nm picosecond laser was effective in treatment of melasma and skin rejuvenation. It was also safe and well tolerated. Importantly, there was no hypo or hyperpigmentation reported. Lasers Surg. Med. 00:00-00, 2021. © 2021 Wiley Periodicals LLC.


Asunto(s)
Hiperpigmentación , Láseres de Estado Sólido , Melanosis , Envejecimiento de la Piel , Adulto , Pueblo Asiatico , Humanos , Láseres de Estado Sólido/uso terapéutico , Melanosis/terapia , Persona de Mediana Edad , Estudios Prospectivos , Rejuvenecimiento , Resultado del Tratamiento
5.
Ophthalmic Physiol Opt ; 41(1): 171-178, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33119966

RESUMEN

PURPOSE: To investigate the effect of simultaneous dual-focus (DF) on retinal activities measured by global flash multifocal electroretinogram (mfERG). METHODS: Thirty adults were recruited for mfERG measurement under three conditions: in-focus (i.e., no defocus), +2.50 D DF and +7.50 D DF, administered using single vision contact lenses and DF lenses. The direct component (DC) and the induced component (IC) of the mfERG were pooled into central macular (0-8°), para-macular (8-18°) and peri-macular (18-30°) regions, and then compared across the three conditions using two-way, repeated measures ANOVA. RESULTS: Simultaneous DF had a significant effect on the IC amplitude, which was significantly stronger under +7.50 D DF (p < 0.01) than for the in-focus condition, which was mostly derived from the central and para-macular regions. No significant effect was observed for the +2.50 D DF condition. CONCLUSION: Under the effect of relatively strong simultaneous DF integration, the retina showed an enhanced retinal response, which originated from the inner retina. Compared with the peri-macular region, central and para-macular responses appeared to be enhanced.


Asunto(s)
Electrorretinografía , Estimulación Luminosa , Retina/fisiología , Adulto , Lentes de Contacto , Estudios Cruzados , Femenino , Humanos , Masculino , Adulto Joven
6.
Lasers Surg Med ; 51(1): 14-22, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30357871

RESUMEN

BACKGROUND AND OBJECTIVES: Cutaneous pigmentary disorders are both more common and more difficult to treat in patients with skin color given the higher melanin content in the epidermis. Although Q-switched lasers are widely considered to be the standard treatment for both epidermal and dermal pigmentary conditions, a very high risk of post-inflammatory hyperpigmentation (PIH) of up to 25% is seen in patients with skin of color. Recently, the novel picosecond laser with pulse durations operating at sub-nanosecond domains has been shown to be effective in tattoo removal and in the treatment of acne scars. The objective of this study is to examine the safety and efficacy of the dual wavelength picosecond laser for the treatment of benign pigmented skin lesions in Asian patients. METHODS: Twelve subjects with benign pigmentary disorders and Fitzpatrick skin types III to IV were recruited in a prospective clinical study to examine the safety and efficacy of the dual wavelength picosecond laser. Patients were treated at approximately 2-6 week intervals depending of the type of lesion. The primary efficacy endpoint is the global percent of clearance which was evaluated by blinded observers using post treatment photographs compared to baseline photographs. Safety was evaluated before and after each laser treatment and patients were asked to rate the level of pain according to the Visual Analog Scale after each treatment session. Patient satisfaction was assessed at the completion of treatment with questionnaires. All patients were followed up at 4, 8, and 12 weeks after the last treatment session. RESULTS: The pigmentary conditions treated included melasma, freckles, lentiginies, café au lait macules, and Hori's macules. Three months after treatment, 53.8% of all pigments achieved excellent response (75-94% lightening,) 30.8% of pigments achieved good response (50-74% lightening,) and 7.7% of pigments achieved both fair (25-49% lightening) and poor responses (0-24% lightening), respectively. The average number of treatment sessions required to reach at least 50% clearance was 4.5 for melasma, 1 for freckles, 1.5 for lentigines and 1 for café au lait. The patient with Hori's macules did not reach 50% clearance after a total of six treatments. Sixty three percent of patients reported satisfaction in the subjective assessment, while 27.3% were neutral and 9.1% were very dissatisfied. The post inflammatory hyperpigmentation rate was 4.8% and 6.5% of subjects developed blistering as a side effect of treatment. CONCLUSION: The dual wavelength picosecond laser is a safe and effective treatment of benign pigmentary conditions in patients with skin of color. In particular, superior clinical efficacy is demonstrated for treatment of freckles and lentigines with a low risk of PIH. Lasers Surg. Med. 51:14-22, 2019. © 2018 Wiley Periodicals, Inc.


Asunto(s)
Cara , Hiperpigmentación/radioterapia , Láseres de Estado Sólido/uso terapéutico , Terapia por Luz de Baja Intensidad/métodos , Adulto , Estética , Femenino , Hong Kong , Humanos , Persona de Mediana Edad , Seguridad del Paciente , Estudios Prospectivos
7.
Lasers Surg Med ; 50(1): 13-19, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29154457

RESUMEN

BACKGROUND AND OBJECTIVE: Microfocused ultrasound (MFUS) technology has been utilized since 2009 for improvement in mild to moderate skin and soft tissue laxity of the face and neck. Few complications have been previously reported, the majority of which include mild and transient erythema, edema, ecchymosis, and nerve paralysis. Rare yet serious potential complications of MFUS for noninvasive skin tightening of the face and neck are, however, possible. METHODS & MATERIALS: Retrospective multicenter case series of five patients from the authors' practice who developed serious adverse events directly related to MFUS with a commercially available device (Ultherapy; Merz North America, Inc., Raleigh, NC). RESULTS: Five patients developed blistering, erosion/ulceration, cutaneous, or subcutaneous tissue edema with resulting atrophy, and/or cutaneous necrosis following single sessions of MFUS. CONCLUSION: Despite their rarity, serious adverse events secondary to MFUS are nevertheless possible and may be underreported. Early management of complications includes local wound care, patient reassurance, and topical corticosteroids and/or pulsed-dye laser to mitigate inflammatory sequelae. Other cosmetic and surgical therapies should be utilized when conservative measures have failed. Lasers Surg. Med. 50:13-19, 2018. © 2017 Wiley Periodicals, Inc.


Asunto(s)
Técnicas Cosméticas/efectos adversos , Ultrasonido Enfocado de Alta Intensidad de Ablación/efectos adversos , Envejecimiento de la Piel , Adulto , Técnicas Cosméticas/instrumentación , Cara , Femenino , Ultrasonido Enfocado de Alta Intensidad de Ablación/instrumentación , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
8.
Lasers Surg Med ; 48(2): 203-7, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26352171

RESUMEN

BACKGROUND AND OBJECTIVE: Several studies have been published on the first generation non-thermal focused ultrasound with an average improvement of 0-3.95 cm reported. We aim to investigate the efficacy of the second-generation non-thermal focused ultrasound device with a combined radiofrequency hand piece. With the addition of radiofrequency energy, the temperature of the adipose tissue is raised before focused ultrasound is applied. This facilitates the mechanical disruption of fat cells by focused ultrasound. STUDY DESIGN AND METHODS: Twenty subjects were recruited and underwent three treatments biweekly. Caliper reading, abdominal circumference, and standardized photographs were taken with the Vectra(®) system at all visits. We aim to have the subjects stand and hold the same position and the photograph taken after exhalation. Caliper and circumference measurements carry uncertainty. It is impossible to eliminate all uncertainties but can be improved by having the same trained physician assistant perform the measurement at the same site and taking an average of three readings. Pain score and satisfaction were recorded by means of the visual analogue scale. The efficacy is defined by a statistically significant improvement in circumferential improvement based on intention-to-treat analysis. RESULTS: Seventeen subjects completed the treatment schedule. Abdominal circumference showed statistically significant improvement at 2 weeks post-second treatment (P = 0.023) and almost all subsequent follow-ups. Caliper readings were statistically significant at 2 weeks post-second treatment (P = 0.013) and almost all follow-ups. The mean pain score reported was 2.3 on the visual analog scale and 6% were unsatisfied with the overall treatments. Six incidents of wheal formation appeared immediately after treatment all of which subsided spontaneously within several hours. CONCLUSION: The combination non-thermal focused ultrasound and radiofrequency device is effective for improving body contour in Asians.


Asunto(s)
Pueblo Asiatico , Técnicas Cosméticas/instrumentación , Terapia por Radiofrecuencia , Grasa Subcutánea Abdominal , Terapia por Ultrasonido/instrumentación , Adolescente , Adulto , China , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud , Satisfacción del Paciente/estadística & datos numéricos , Estudios Prospectivos , Terapia por Ultrasonido/métodos , Adulto Joven
9.
Lasers Surg Med ; 46(4): 263-9, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24585511

RESUMEN

BACKGROUND AND OBJECTIVES: High-intensity focused ultrasound (HIFU) is a noninvasive technology for body contouring. HIFU is focused within the subcutaneous adipose tissue, causing coagulative necrosis and cell death. The objective of this study is to evaluate the effectiveness of a HIFU device for sculpting of the abdomen. MATERIALS AND METHODS: The system has a set focal depth of 1.3 cm. Twelve subjects with adipose thickness no less than 2.5 cm who met the screening criteria were recruited. Each subject received one treatment to the abdomen. The total fluence used per site was 150-165 J/cm(2) with a mean of 161 J/cm(2) . The waist circumference at iliac crest and the point of maximum circumference were recorded at baseline, 4, 8, and 12 weeks post-treatment, as well as their weight and BMI. Subjects' rating on comfort level and satisfaction were collected via questionnaires at every follow-up. Standardized photographs were also taken with the Canfield System® at each visit. RESULTS: Seven out of 12 subjects were satisfied with the outcome and 9 out of 12 would recommend this treatment to their friends and family. There was statistically significant improvement in the waist circumference measured at both the iliac crest (P-value 0.013, 0.002, 0.005) and maximum waistline (P-value 0.003, 0.034, 0.023) at 4, 8, 12 weeks post-treatment. Spearman's rho for correlation of energy level versus improvement showed that at 12 weeks post-treatment follow-up, the improvement significantly correlated with the total fluence per treatment (P-value 0.041). The higher the total fluence delivered, the larger the decrease in waist circumference. CONCLUSIONS: High-intensity focused ultrasound effectively decreases waist circumference in Chinese. The higher the total fluence delivered, the larger the decrease in waist circumference was observed.


Asunto(s)
Técnicas Cosméticas , Ultrasonido Enfocado de Alta Intensidad de Ablación , Grasa Subcutánea Abdominal/diagnóstico por imagen , Adolescente , Adulto , Anciano , Pueblo Asiatico , China , Técnicas Cosméticas/instrumentación , Femenino , Estudios de Seguimiento , Ultrasonido Enfocado de Alta Intensidad de Ablación/instrumentación , Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Humanos , Masculino , Persona de Mediana Edad , Evaluación del Resultado de la Atención al Paciente , Satisfacción del Paciente , Estudios Prospectivos , Ultrasonografía , Circunferencia de la Cintura , Adulto Joven
10.
Lasers Surg Med ; 46(5): 375-9, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24634348

RESUMEN

BACKGROUND AND OBJECTIVE: As the demand for diminished procedure-associated downtime continues to increase, nonablative fractional laser resurfacing is becoming a more popular intervention in the progression of photoaging. Patients with pigmented skin and a mild degree of photodamage may be particularly suited for a less intensive laser treatment. In this study, we have evaluated the safety and efficacy of a low energy, low density 1,440-nm fractional laser in the treatment of multiple signs of photoaging including dyspigmentation, wrinkling, tissue laxity, enlarged pores, and skin roughness in Asians. STUDY DESIGN/MATERIALS AND METHODS: Ten Chinese subjects with Fitzpatrick skin types III-V and visible signs of photodamage participated in this study. Patients received four treatments at 2-week intervals with a 1,440-nm diode-based fractional laser. Photographs were taken at baseline, 2 weeks after each of the first three treatments and 4 weeks after the final treatment. Images were evaluated independently by two physicians. Clinical improvement and adverse events were analyzed. Discomfort, heat sensation and overall patient satisfaction associated with the procedure were also quantified. RESULTS: In this prospective single-arm study, signs of photoaging were examined after treatment with the 1,440-nm laser. Here we show that a series of four treatments with this device produced a mild improvement in skin texture, pigmentation, and wrinkling. Changes in pore size and skin laxity failed to reach statistical significance. Immediate after-effects of the procedure included erythema and edema which were transient and left no permanent sequela. A significant proportion of patients reported some degree of discomfort during the procedure despite use of a topical anesthetic. One patient developed a discrete, localized area of post-inflammatory hyperpigmentation which completely resolved by the final follow up visit. CONCLUSION: The low energy, low density nonablative 1,440-nm fractional laser produces a mild improvement in select signs of photodamage after four treatments without any long-term adverse effects.


Asunto(s)
Pueblo Asiatico , Hiperpigmentación/radioterapia , Láseres de Semiconductores/uso terapéutico , Terapia por Luz de Baja Intensidad/métodos , Envejecimiento de la Piel/efectos de la radiación , Piel/efectos de la radiación , Adulto , China , Femenino , Estudios de Seguimiento , Humanos , Hiperpigmentación/etnología , Hiperpigmentación/etiología , Satisfacción del Paciente , Fotograbar , Estudios Prospectivos , Envejecimiento de la Piel/etnología , Resultado del Tratamiento
11.
Int J Dermatol ; 63(6): 704-713, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38643368

RESUMEN

Acne, a highly prevalent skin disease, can be particularly bothersome for patients of Asian background because of its impact on self-confidence and social interactions. In addition to active acne lesions, some patients may develop sequelae such as scarring, macular/postinflammatory hyperpigmentation, or erythema. The tendency of Asian skin to develop sequelae because of its increased susceptibility to irritation, cultural preferences for lighter skin phototypes, and differences in skincare regimens may all contribute to the increased burden of acne. Moreover, many Asia-Pacific countries do not have their own guidelines for acne management, and those that do often have no schedule in place for regular updates. In this article, we provide a critical review of the published guidance for the management of acne and its sequelae in the Asia-Pacific region, identifying gaps in current recommendations that could be addressed to enhance standards of acne care in Asia-Pacific countries. Along with highlighting the importance of a comprehensive skincare regimen to increase treatment efficacy and adherence, we discuss topical retinoids and retinoid combination options in the acne armamentarium that may be beneficial for sequelae prevention and management, such as adapalene 0.3% ± benzoyl peroxide 2.5%, tretinoin 0.05%, tazarotene 0.1%, and trifarotene 0.005%. In particular, trifarotene 0.005% has been observed to significantly reduce acne scar counts in a Phase 4 study. The recent data highlight the need to establish up-to-date guidance for acne and acne sequelae management in Asia-Pacific countries to provide optimal care to Asian patients.


Asunto(s)
Acné Vulgar , Fármacos Dermatológicos , Retinoides , Humanos , Acné Vulgar/tratamiento farmacológico , Acné Vulgar/complicaciones , Fármacos Dermatológicos/administración & dosificación , Fármacos Dermatológicos/uso terapéutico , Fármacos Dermatológicos/efectos adversos , Retinoides/administración & dosificación , Retinoides/uso terapéutico , Retinoides/efectos adversos , Asia , Hiperpigmentación/etiología , Hiperpigmentación/tratamiento farmacológico , Administración Cutánea , Cicatriz/etiología , Cicatriz/tratamiento farmacológico , Guías de Práctica Clínica como Asunto , Cuidados de la Piel/métodos , Eritema/tratamiento farmacológico , Eritema/etiología
12.
Ophthalmic Physiol Opt ; 33(3): 346-53, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23406521

RESUMEN

PURPOSE: Myopia is a complex eye disorder. The X-linked form of complete congenital stationary night blindness (CSNB1A) is usually associated with moderate to high myopia, and is caused by mutations in the NYX gene. We explored if NYX mutations could be associated with high myopia, but not CSNB1A. METHODS: The coding regions of the NYX gene were sequenced for 204 Chinese males with high myopia (-8.00 dioptres or worse for both eyes). The frequencies of any sequence variations identified were determined in 200 Chinese males without myopia. Electro-oculography, electroretinography and standard cone function tests were performed on a male high myope carrying a mutation. RESULTS: A missense mutation (c.529_530GC>AT or p.Ala177Met) was identified in one male subject with high myopia, but not in 200 male emmetropes. Neither was this variant found in any of the 529 male and 567 female subjects of various ethnic backgrounds whose genome sequences are documented in the 1000 Genomes Project database. The mutation was predicted to affect the protein function. From ocular electrophysiological tests, the proband was found to have normal rod function, but mildly abnormal cone function and inner retina function. He did not seem to suffer from CSNB1A. CONCLUSIONS: One novel missense NYX mutation was identified in an adult male presented with high myopia, but without the major electrophysiological features normally associated with CSNB1A. NYX gene mutations may be considered as one of the rare genetic risk factors for high myopia without key features of CSNB1A.


Asunto(s)
Predisposición Genética a la Enfermedad/genética , Mutación Missense/genética , Miopía/genética , Proteoglicanos/genética , Pueblo Asiatico/genética , China , Emetropía/genética , Exones , Humanos , Masculino , Persona de Mediana Edad , Ceguera Nocturna/genética , Análisis de Secuencia de ADN
13.
J Cosmet Laser Ther ; 15(4): 200-6, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23384107

RESUMEN

BACKGROUND: A new fractional photothermolysis device is used in our retrospective study to treat melasma in Chinese patients. OBJECTIVES: To evaluate the efficacy and safety of the 1927 nm fractional thulium fiber laser in the treatment of melasma in Chinese patients. METHODS: Eleven melasma patients who received treatment between November 2009 and May 2010 were included. Photographic images at baseline and follow-up were assessed for clinical efficacy and complications by two independent and blinded physicians. Questionnaires were also completed by patients. RESULTS: Significant MASI improvements were seen at 1 week, 1 month and 2 months, but not at 3 months. Patients' degree of satisfaction was high. Significant improvement in skin texture and pore size was seen for up to 2 months and improvement in wrinkles for up to a month. There was no change in skin laxity. Main adverse effects seen were erythema, edema, and crusting in the early days. One patient developed PIH. CONCLUSION: The novel 1927 nm fractional thulium fiber laser is safe and effective in the management of melasma in Chinese patients for up to 2 months. It is also useful in photo-rejuvenation. Complications were limited to erythema and edema in the early days, and transient PIH.


Asunto(s)
Láseres de Estado Sólido/uso terapéutico , Melanosis/cirugía , Tulio , Adulto , Edema/etiología , Eritema/etiología , Femenino , Humanos , Hiperpigmentación/etiología , Persona de Mediana Edad , Satisfacción del Paciente , Púrpura/etiología , Estudios Retrospectivos , Envejecimiento de la Piel
14.
J Clin Med ; 12(9)2023 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-37176650

RESUMEN

Myopia control efficacy and long-term safety of the Breath-O-Correct orthokeratology (OK) lens was evaluated in a 2-year randomized, single vision (SV) spectacle lens-controlled, single-blind clinical trial combining clinical and tear proteomics data. A total of 71 children (43 OK, 9.8 ± 1.3 years; 28 SV, 9.5 ± 1.4 years) completed the 2-year study. Axial length (AL), cycloplegic refraction, clinical safety parameters (best-corrected visual acuity, central cornea thickness, corneal endothelial health, ocular surface disease index), and quantitative tear proteomics were evaluated by masked examiners. Mean 2-year-normalized AL elongations in the OK and SV groups differed significantly (p = 0.03) and were 0.37 ± 0.37 mm and 0.60 ± 0.41 mm, respectively. OK-mediated myopia control efficacy was 37.1%. No significant difference was found in clinical safety parameters of both groups (p > 0.10), except for a thinner central corneal thickness in the OK group (p = 0.01). Proteomics revealed modest OK lens-mediated effects on immune response proteins, including an increased abundance of haptoglobin at 6 and 12 months and a decreased abundance of two proteins (neutrophil defensin 3 and histone 4) at 6 months. The changes were further validated using a high-resolution multiple-reaction monitoring (MRMHR) mass spectrometry. In summary, the Breath-O-Correct OK lens significantly reduced AL elongation in schoolchildren without adverse clinical effects or subclinical inflammatory responses.

15.
Graefes Arch Clin Exp Ophthalmol ; 250(12): 1745-54, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22527315

RESUMEN

PURPOSE: To investigate early functional changes of local retinal defects in type II diabetic patients using the global flash multifocal electroretinogram (MOFO mfERG). METHODS: Thirty-eight diabetic patients and 14 age-matched controls were recruited. Nine of the diabetics were free from diabetic retinopathy (DR), while the remainder had mild to moderate non-proliferative diabetic retinopathy. The MOFO mfERG was performed at high (98 %) and low (46 %) contrast levels. MfERG responses were grouped into 35 regions for comparison with DR classification at those locations. Z-scores of the regional mfERG responses were compared across different types of DR defects. RESULTS: The mfERG waveform consisted of the direct component (DC) and the induced component (IC). Local reduction in DC and IC amplitudes were found in diabetic patients with and without DR. With increasing severity of retinopathy, there was a further deterioration in amplitude of both components. Under MOFO mfERG paradigm, amplitude was a useful screening parameter. CONCLUSION: The MOFO mfERG can help in detecting early functional anomalies before the appearance of visible signs, and may assist in monitoring further functional deterioration in diabetic patients.


Asunto(s)
Diabetes Mellitus Tipo 2/fisiopatología , Retinopatía Diabética/fisiopatología , Retina/fisiopatología , Glucemia/metabolismo , Sensibilidad de Contraste/fisiología , Electrorretinografía , Humanos , Persona de Mediana Edad , Estimulación Luminosa , Agudeza Visual/fisiología
16.
Graefes Arch Clin Exp Ophthalmol ; 250(2): 261-70, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21881844

RESUMEN

PURPOSE: To investigate the association of the luminance-modulation global flash multifocal electroretinogram (mfERG) and other clinical assessments of vision in subsets of subjects at high risk of developing glaucomatous damage. METHODS: Eighteen subjects (28 eyes) with asymmetric glaucoma and ocular hypertension were measured in this longitudinal study of visual field, OCT, and multifocal electroretinogram (mfERG). Five ophthalmic examinations were scheduled, once every 12 months over a 4-year period. The mfERG was assessed using a luminance-modulated global flash stimulation paradigm. The adaptive index which we have reported previously was calculated. RESULTS: There was a significant thinning of the peripapillary retinal nerve fiber layer over the course of the study for eyes with ocular hypertension, or for fellow eyes with asymmetric glaucoma which initially had an abnormal adaptive index; such eyes showed a thinning rate of -3.59 and -3.69 µm/year, respectively. However, no significant thinning was found for eyes which initially had a normal adaptive index. Two subjects were shown to have glaucomatous damage, confirmed by abnormal thinning of the retinal nerve fiber layer and visual field loss respectively at the last visit. However, these patients had shown an abnormal adaptive index in the mfERG measurement at the first visit. CONCLUSIONS: The adaptive index calculated from the measurement of luminance-modulated global flash mfERG is useful for predicting progression of signs related to glaucoma, especially in high-risk groups. The abnormal adaptive index reflects the change in fast-adaptive mechanisms in the retina and indicates the risk of developing glaucoma.


Asunto(s)
Adaptación Ocular , Electrorretinografía , Glaucoma de Ángulo Abierto/fisiopatología , Retina/fisiopatología , Adolescente , Adulto , Antihipertensivos/uso terapéutico , Estudios de Seguimiento , Glaucoma de Ángulo Abierto/tratamiento farmacológico , Humanos , Presión Intraocular/fisiología , Persona de Mediana Edad , Fibras Nerviosas/patología , Hipertensión Ocular/tratamiento farmacológico , Hipertensión Ocular/fisiopatología , Estimulación Luminosa , Células Ganglionares de la Retina/patología , Tomografía de Coherencia Óptica , Tonometría Ocular , Trastornos de la Visión/fisiopatología , Agudeza Visual/fisiología , Campos Visuales/fisiología
17.
Lasers Surg Med ; 44(8): 622-30, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22899398

RESUMEN

BACKGROUND AND OBJECTIVES: Fractionated radiofrequency (RF) induces deep dermal heating and leaves the epidermis less affected. We studied the efficacy and safety of bipolar RF and fractional diode laser followed by fractional RF in Asians with acne scars. MATERIALS AND METHODS: Twenty-four patients (skin types III and IV) with acne scars received up to five treatments of combined fractional 915-nm laser and bipolar RF using a Matrix IR applicator (Syneron Medical Ltd, Yokneam, Israel) with fluence ranging from 50 to 70 J/cm(2) , RF at 70-100 J/cm(3) , double passes followed by full-face bipolar fractional RF treatment using Matrix RF at energy ranging from 50 to 62 mJ/pin, at 4-week intervals. Changes in acne scars, skin texture, pore size, pigmentation irregularity, and complications were assessed up to 3 months post-treatment by standardized photographs obtained with Canfield Visia-CR system®. Subjective improvement and patient satisfaction were assessed by questionnaire. RESULTS: Twenty patients (age 27.7 ± 8.4 years) completed the study. Modest but statistically significant improvement was noted in acne scars, with the mean grade decreased by 29% (P < 0.001), and 52% were rated with at least moderate objective global improvement at 3 months. Mean pain score was 2.6 on a scale of 0-4. There were also objective improvements in all secondary endpoints. Post-inflammatory hyperpigmentation (PIH) occurred mainly over bony areas in 6.5% of all treatments. Subjective improvement was moderate to significant for 36.8% of patients, and 63% reported being satisfied with the treatment results at 3 months despite considerable pain level. CONCLUSION: Use of fractional laser with RF followed by fractional RF was shown to be safe and effective for acne scars with modest improvement and low PIH rate comparable to other resurfacing techniques in this Asian case series. Adequate pain control and recduced energy level when treating areas in close proximity to bone are advised. Lasers Surg. Med. 44: 622-630, 2012. © 2012 Wiley Periodicals, Inc.


Asunto(s)
Acné Vulgar/complicaciones , Cicatriz/terapia , Láseres de Semiconductores , Terapia por Radiofrecuencia , Adulto , Pueblo Asiatico , Cicatriz/etiología , Fraccionamiento de la Dosis de Radiación , Eritema/etiología , Femenino , Humanos , Hiperpigmentación/etiología , Masculino , Dimensión del Dolor , Satisfacción del Paciente , Estudios Prospectivos
18.
Sci Rep ; 12(1): 11588, 2022 07 08.
Artículo en Inglés | MEDLINE | ID: mdl-35804049

RESUMEN

This study aimed to evaluate the efficacy of 18-month 0.01% atropine in 61 myopic children (aged 7-10) and the relationship with central retinal response (by multifocal electroretinogram [mfERG]) in a double-masked randomized placebo-controlled clinical trial. Global-flash mfERG was measured at baseline, while cycloplegic spherical equivalent refraction (SER) and axial length (AL) were measured at baseline and at 6-month intervals. Annualized change in SER and AL were compared between atropine and control groups, and the relationships with baseline mfERG were evaluated. Changes in SER (-0.70 ± 0.39D vs. -0.66 ± 0.41D, p = 0.63) and AL (0.32 ± 0.16 mm vs. 0.30 ± 0.22 mm, p = 0.52) were similar in atropine and control groups. Interestingly, in the placebo group, mfERG amplitude was negatively correlated with axial elongation (Rp = -0.44, p = 0.03) as in our previous study. However, in the atropine group, an opposite trend was observed that axial elongation was positively correlated with mfERG amplitude (Ra = 0.37, p = 0.04). Annualized myopia progression demonstrated similar opposite effect between atropine and placebo groups but did not reach statistical significance. An ERG screening protocol may be warranted to identify suitable candidates to reduce the likelihood of an unfavorable treatment response by 0.01% atropine.


Asunto(s)
Atropina , Miopía , Longitud Axial del Ojo , Niño , Progresión de la Enfermedad , Humanos , Miopía/tratamiento farmacológico , Soluciones Oftálmicas , Refracción Ocular , Pruebas de Visión
19.
Int J Dermatol ; 61(2): 184-190, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34553372

RESUMEN

BACKGROUND: HLA-B*15:11 is associated with carbamazepine (CBZ)-induced severe cutaneous adverse drug reactions (SCARs) in Japanese and some Asian populations, but such data remains relatively limited in Chinese. Routine HLA-B*15:02 screening is mandatory before CBZ commencement, however, SCARs related to CBZ were still observed in non-HLA*B-15:02 carriers. OBJECTIVE: We aimed to find out the prevalence of HLA-B*15:11 in Chinese patients and its associations with CBZ-induced SCARs. METHOD: We screened 8,328 blood samples collected for HLA allele typing before CBZ commencement during the period of January 2014 to December 2019. In HLA-B*15:02 negative Chinese patients, HLA-B*15:11 status were further screened, and the incidence of SCARs in the CBZ group was compared with the control group without CBZ use. RESULT: In this cohort, 1416 out of 8328 patients (17%) tested HLA-B*15:02 positive and were advised to avoid CBZ, while 80 (0.96%) were found to be HLA-B*15:11 positive. In 6911 (83%) patients who tested HLA-B*15:02 negative, 70 (1.01%) were HLA-B*15:11 positive. Five out of 70 (7.14%) patients had SCARs. The incidence of SCARs in HLA-B*15:11 carriers who received CBZ was significantly higher than those without CBZ (17.4% [4/23] vs. 2.13% [1/47], P = 0.037*). The odds ratio was 9.68 (95% CI 1.02-92.4, P = 0.048*). These included: one Stevens-Johnson syndrome (SJS), two DRESS, and one MPE after CBZ use, while one developed MPE after phenytoin use in control. CONCLUSION: HLA-B*15:11 is a potential risk factor of CBZ-induced SCARs in HLA-B*15:02 negative Chinese patients. Further screening of HLA-B*15:11 status in those HLA-B*15:02 negative patients is recommended to avoid undesirable SCARs.


Asunto(s)
Anticonvulsivantes , Síndrome de Stevens-Johnson , Carbamazepina , China , Predisposición Genética a la Enfermedad , Antígenos HLA-B/genética , Antígeno HLA-B15/genética , Humanos
20.
Lasers Surg Med ; 43(5): 366-75, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21674541

RESUMEN

BACKGROUND AND OBJECTIVES: Transcutaneous intense focused ultrasound has emerged as a novel technology for non-invasive skin tightening. The objective of this study was to evaluate the safety profile of a transcutaneous focused ultrasound device for the treatment of facial skin laxity in Asians. MATERIALS AND METHODS: The patients received one to three full-face treatments with the transcutaneous focused ultrasound device. Three transducers (7.0 MHz, 3.0 mm focal depth; 7.0 MHz, 4.5 mm focal depth; 4.0 MHz, 4.5 mm focal depth) were used to deliver a single pass of microthermal coagulation zones without any topical anesthetics. Standardized photos were taken at baseline and at each follow-up with the Canfield Visia CR system® and were assessed by two independent physicians. Adverse effects were assessed up to 6 months post treatment. Subjective assessments in terms of pain and tolerability were also evaluated with patient questionnaires. RESULTS: Forty nine Chinese patients (skin types III-IV, mean age 53.3) completed a total of 68 treatment sessions. Transient erythema and edema were seen in the majority of patients. Focal bruising was present in up to 25% of treatment sessions. Two cases of post-inflammatory hyperpigmentation were seen on the forehead at 1-month post-treatment. One patient experienced focal twitching over the lower eyelid at 1-month follow-up, which was clinically consistent with hemifacial spasm and was unrelated to the ultrasound device. The degree of pain during treatment was recorded as severe in 54.4% of treatment sessions. CONCLUSIONS: Transcutaneous intense focused ultrasound appeared to be safe for non-invasive facial skin tightening in Asians. Adverse events were mild and transient. Pain control during treatment should be optimized. No serious permanent or delayed side effects were noted up to 6 months post treatment.


Asunto(s)
Pueblo Asiatico , Técnicas Cosméticas , Envejecimiento de la Piel/etnología , Piel/diagnóstico por imagen , Terapia por Ultrasonido/métodos , Adulto , China , Técnicas Cosméticas/efectos adversos , Técnicas Cosméticas/instrumentación , Cara/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Transductores , Resultado del Tratamiento , Terapia por Ultrasonido/efectos adversos , Terapia por Ultrasonido/instrumentación , Ultrasonografía