Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Magn Reson Imaging ; 2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38703134

RESUMEN

BACKGROUND: Cartilage T2 can detect joints at risk of developing osteoarthritis. The quantitative double-echo steady state (qDESS) sequence is attractive for knee cartilage T2 mapping because of its acquisition time of under 5 minutes. Understanding the reproducibility errors associated with qDESS T2 is essential to profiling the technical performance of this biomarker. PURPOSE: To examine the combined acquisition and segmentation reproducibility of knee cartilage qDESS T2 using two different regional analysis schemes: 1) manual segmentation of subregions loaded during common activities and 2) automatic subregional segmentation. STUDY TYPE: Prospective. SUBJECTS: 11 uninjured participants (age: 28 ± 3 years; 8 (73%) female). FIELD STRENGTH/SEQUENCE: 3-T, qDESS. ASSESSMENT: Test-retest T2 maps were acquired twice on the same day and with a 1-week interval between scans. For each acquisition, average cartilage T2 was calculated in four manually segmented regions encompassing tibiofemoral contact areas during common activities and 12 automatically segmented regions from the deep-learning open-source framework for musculoskeletal MRI analysis (DOSMA) encompassing medial and lateral anterior, central, and posterior tibiofemoral regions. Test-retest T2 values from matching regions were used to evaluate reproducibility. STATISTICAL TESTS: Coefficients of variation (%CV), root-mean-square-average-CV (%RMSA-CV), and intraclass correlation coefficients (ICCs) assessed test-retest T2 reproducibility. The median of test-retest standard deviations was used for T2 precision. Bland-Altman (BA) analyses examined test-retest biases. The smallest detectable difference (SDD) was defined as the BA limit of agreement of largest magnitude. Significance was accepted for P < 0.05. RESULTS: All cartilage regions across both segmentation schemes demonstrated intraday and interday qDESS T2 CVs and RMSA-CVs of ≤5%. T2 ICC values >0.75 were observed in the majority of regions but were more variable in interday tibial comparisons. Test-retest T2 precision was <1.3 msec. The T2 SDD was 3.8 msec. DATA CONCLUSION: Excellent CV and RMSA-CV reproducibility may suggest that qDESS T2 increases or decreases >5% (3.8 msec) could represent changes to cartilage composition. TECHNICAL EFFICACY: Stage 2.

2.
PLoS Comput Biol ; 19(10): e1011462, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37856442

RESUMEN

Measures of human movement dynamics can predict outcomes like injury risk or musculoskeletal disease progression. However, these measures are rarely quantified in large-scale research studies or clinical practice due to the prohibitive cost, time, and expertise required. Here we present and validate OpenCap, an open-source platform for computing both the kinematics (i.e., motion) and dynamics (i.e., forces) of human movement using videos captured from two or more smartphones. OpenCap leverages pose estimation algorithms to identify body landmarks from videos; deep learning and biomechanical models to estimate three-dimensional kinematics; and physics-based simulations to estimate muscle activations and musculoskeletal dynamics. OpenCap's web application enables users to collect synchronous videos and visualize movement data that is automatically processed in the cloud, thereby eliminating the need for specialized hardware, software, and expertise. We show that OpenCap accurately predicts dynamic measures, like muscle activations, joint loads, and joint moments, which can be used to screen for disease risk, evaluate intervention efficacy, assess between-group movement differences, and inform rehabilitation decisions. Additionally, we demonstrate OpenCap's practical utility through a 100-subject field study, where a clinician using OpenCap estimated musculoskeletal dynamics 25 times faster than a laboratory-based approach at less than 1% of the cost. By democratizing access to human movement analysis, OpenCap can accelerate the incorporation of biomechanical metrics into large-scale research studies, clinical trials, and clinical practice.


Asunto(s)
Modelos Biológicos , Teléfono Inteligente , Humanos , Músculos/fisiología , Programas Informáticos , Fenómenos Biomecánicos , Movimiento/fisiología
3.
Eur Radiol ; 2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38683384

RESUMEN

OBJECTIVES: To develop and validate an open-source artificial intelligence (AI) algorithm to accurately detect contrast phases in abdominal CT scans. MATERIALS AND METHODS: Retrospective study aimed to develop an AI algorithm trained on 739 abdominal CT exams from 2016 to 2021, from 200 unique patients, covering 1545 axial series. We performed segmentation of five key anatomic structures-aorta, portal vein, inferior vena cava, renal parenchyma, and renal pelvis-using TotalSegmentator, a deep learning-based tool for multi-organ segmentation, and a rule-based approach to extract the renal pelvis. Radiomics features were extracted from the anatomical structures for use in a gradient-boosting classifier to identify four contrast phases: non-contrast, arterial, venous, and delayed. Internal and external validation was performed using the F1 score and other classification metrics, on the external dataset "VinDr-Multiphase CT". RESULTS: The training dataset consisted of 172 patients (mean age, 70 years ± 8, 22% women), and the internal test set included 28 patients (mean age, 68 years ± 8, 14% women). In internal validation, the classifier achieved an accuracy of 92.3%, with an average F1 score of 90.7%. During external validation, the algorithm maintained an accuracy of 90.1%, with an average F1 score of 82.6%. Shapley feature attribution analysis indicated that renal and vascular radiodensity values were the most important for phase classification. CONCLUSION: An open-source and interpretable AI algorithm accurately detects contrast phases in abdominal CT scans, with high accuracy and F1 scores in internal and external validation, confirming its generalization capability. CLINICAL RELEVANCE STATEMENT: Contrast phase detection in abdominal CT scans is a critical step for downstream AI applications, deploying algorithms in the clinical setting, and for quantifying imaging biomarkers, ultimately allowing for better diagnostics and increased access to diagnostic imaging. KEY POINTS: Digital Imaging and Communications in Medicine labels are inaccurate for determining the abdominal CT scan phase. AI provides great help in accurately discriminating the contrast phase. Accurate contrast phase determination aids downstream AI applications and biomarker quantification.

4.
AJR Am J Roentgenol ; 222(1): e2329889, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37877596

RESUMEN

BACKGROUND. Sarcopenia is commonly assessed on CT by use of the skeletal muscle index (SMI), which is calculated as the skeletal muscle area (SMA) at L3 divided by patient height squared (i.e., a height scaling power of 2). OBJECTIVE. The purpose of this study was to determine the optimal height scaling power for SMA measurements on CT and to test the influence of the derived optimal scaling power on the utility of SMI in predicting all-cause mortality. METHODS. This retrospective study included 16,575 patients (6985 men, 9590 women; mean age, 56.4 years) who underwent abdominal CT from December 2012 through October 2018. The SMA at L3 was determined using automated software. The sample was stratified into two groups: 5459 patients without major medical conditions (based on ICD-9 and ICD-10 codes) who were included in the analysis for determining the optimal height scaling power and 11,116 patients with major medical conditions who were included for the purpose of testing this power. The optimal scaling power was determined by allometric analysis (whereby regression coefficients were fitted to log-linear sex-specific models relating height to SMA) and by analysis of statistical independence of SMI from height across scaling powers. Cox proportional hazards models were used to test the influence of the derived optimal scaling power on the utility of SMI in predicting all-cause mortality. RESULTS. In allometric analysis, the regression coefficient of log(height) in patients 40 years old and younger was 1.02 in men and 1.08 in women, and in patients older than 40 years old, it was 1.07 in men and 1.10 in women (all p < .05 vs regression coefficient of 2). In analyses for statistical independence of SMI from height, the optimal height scaling power (i.e., those yielding correlations closest to 0) was, in patients 40 years old and younger, 0.97 in men and 1.08 in women, whereas in patients older than 40 years old, it was 1.03 in men and 1.09 in women. In the Cox model used for testing, SMI predicted all-cause mortality with a higher concordance index using of a height scaling power of 1 rather than 2 in men (0.675 vs 0.663, p < .001) and in women (0.664 vs 0.653, p < .001). CONCLUSION. The findings support a height scaling power of 1, rather than a conventional power of 2, for SMI computation. CLINICAL IMPACT. A revised height scaling power for SMI could impact the utility of CT-based sarcopenia diagnoses in risk assessment.


Asunto(s)
Sarcopenia , Masculino , Humanos , Femenino , Persona de Mediana Edad , Adulto , Sarcopenia/etiología , Estudios Retrospectivos , Músculo Esquelético/patología , Modelos de Riesgos Proporcionales , Tomografía Computarizada por Rayos X/métodos
5.
AJR Am J Roentgenol ; 2024 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-38809123

RESUMEN

Artificial intelligence (AI) is transforming medical imaging of adult patients. However, its utilization in pediatric oncology imaging remains constrained, in part due to the inherent data scarcity associated with childhood cancers. Pediatric cancers are rare, and imaging technologies are evolving rapidly, leading to insufficient data of a particular type to effectively train these algorithms. The small market size of pediatrics compared to adults could also contribute to this challenge, as market size is a driver of commercialization. This article provides an overview of the current state of AI applications for pediatric cancer imaging, including applications for medical image acquisition, processing, reconstruction, segmentation, diagnosis, staging, and treatment response monitoring. While current developments are promising, impediments due to diverse anatomies of growing children and nonstandardized imaging protocols have led to limited clinical translation thus far. Opportunities include leveraging reconstruction algorithms to achieve accelerated low-dose imaging and automating the generation of metric-based staging and treatment monitoring scores. Transfer-learning of adult-based AI models to pediatric cancers, multi-institutional data sharing, and ethical data privacy practices for pediatric patients with rare cancers will be keys to unlocking AI's full potential for clinical translation and improved outcomes for these young patients.

6.
Semin Musculoskelet Radiol ; 28(1): 78-91, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38330972

RESUMEN

The importance and impact of imaging biomarkers has been increasing over the past few decades. We review the relevant clinical and imaging terminology needed to understand the clinical and research applications of body composition. Imaging biomarkers of bone, muscle, and fat tissues obtained with dual-energy X-ray absorptiometry, computed tomography, magnetic resonance imaging, and ultrasonography are described.


Asunto(s)
Composición Corporal , Imagen por Resonancia Magnética , Humanos , Composición Corporal/fisiología , Absorciometría de Fotón/métodos , Imagen por Resonancia Magnética/métodos , Ultrasonografía , Tomografía Computarizada por Rayos X/métodos
7.
MAGMA ; 2024 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-39042206

RESUMEN

Deep learning (DL) has recently emerged as a pivotal technology for enhancing magnetic resonance imaging (MRI), a critical tool in diagnostic radiology. This review paper provides a comprehensive overview of recent advances in DL for MRI reconstruction, and focuses on various DL approaches and architectures designed to improve image quality, accelerate scans, and address data-related challenges. It explores end-to-end neural networks, pre-trained and generative models, and self-supervised methods, and highlights their contributions to overcoming traditional MRI limitations. It also discusses the role of DL in optimizing acquisition protocols, enhancing robustness against distribution shifts, and tackling biases. Drawing on the extensive literature and practical insights, it outlines current successes, limitations, and future directions for leveraging DL in MRI reconstruction, while emphasizing the potential of DL to significantly impact clinical imaging practices.Affiliations [3 and 6] has been split into two different affiliations. Please check if action taken is appropriate and amend if necessary.looks good.

8.
Int J Mol Sci ; 25(10)2024 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-38791508

RESUMEN

Cryogenic electron tomography (cryoET) is a powerful tool in structural biology, enabling detailed 3D imaging of biological specimens at a resolution of nanometers. Despite its potential, cryoET faces challenges such as the missing wedge problem, which limits reconstruction quality due to incomplete data collection angles. Recently, supervised deep learning methods leveraging convolutional neural networks (CNNs) have considerably addressed this issue; however, their pretraining requirements render them susceptible to inaccuracies and artifacts, particularly when representative training data is scarce. To overcome these limitations, we introduce a proof-of-concept unsupervised learning approach using coordinate networks (CNs) that optimizes network weights directly against input projections. This eliminates the need for pretraining, reducing reconstruction runtime by 3-20× compared to supervised methods. Our in silico results show improved shape completion and reduction of missing wedge artifacts, assessed through several voxel-based image quality metrics in real space and a novel directional Fourier Shell Correlation (FSC) metric. Our study illuminates benefits and considerations of both supervised and unsupervised approaches, guiding the development of improved reconstruction strategies.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Redes Neurales de la Computación , Aprendizaje Automático no Supervisado , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Tomografía con Microscopio Electrónico/métodos , Microscopía por Crioelectrón/métodos , Algoritmos , Aprendizaje Profundo
9.
Magn Reson Med ; 89(2): 577-593, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36161727

RESUMEN

PURPOSE: To develop and validate a method for B 0 $$ {B}_0 $$ mapping for knee imaging using the quantitative Double-Echo in Steady-State (qDESS) exploiting the phase difference ( Δ Î¸ $$ \Delta \theta $$ ) between the two echoes acquired. Contrary to a two-gradient-echo (2-GRE) method, Δ Î¸ $$ \Delta \theta $$ depends only on the first echo time. METHODS: Bloch simulations were applied to investigate robustness to noise of the proposed methodology and all imaging studies were validated with phantoms and in vivo simultaneous bilateral knee acquisitions. Two phantoms and five healthy subjects were scanned using qDESS, water saturation shift referencing (WASSR), and multi-GRE sequences. Δ B 0 $$ \Delta {B}_0 $$ maps were calculated with the qDESS and the 2-GRE methods and compared against those obtained with WASSR. The comparison was quantitatively assessed exploiting pixel-wise difference maps, Bland-Altman (BA) analysis, and Lin's concordance coefficient ( ρ c $$ {\rho}_c $$ ). For in vivo subjects, the comparison was assessed in cartilage using average values in six subregions. RESULTS: The proposed method for measuring Δ B 0 $$ \Delta {B}_0 $$ inhomogeneities from a qDESS acquisition provided Δ B 0 $$ \Delta {B}_0 $$ maps that were in good agreement with those obtained using WASSR. Δ B 0 $$ \Delta {B}_0 $$ ρ c $$ {\rho}_c $$ values were ≥ $$ \ge $$ 0.98 and 0.90 in phantoms and in vivo, respectively. The agreement between qDESS and WASSR was comparable to that of a 2-GRE method. CONCLUSION: The proposed method may allow B0 correction for qDESS T 2 $$ {T}_2 $$ mapping using an inherently co-registered Δ B 0 $$ \Delta {B}_0 $$ map without requiring an additional B0 measurement sequence. More generally, the method may help shorten knee imaging protocols that require an auxiliary Δ B 0 $$ \Delta {B}_0 $$ map by exploiting a qDESS acquisition that also provides T 2 $$ {T}_2 $$ measurements and high-quality morphological imaging.


Asunto(s)
Rodilla , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Rodilla/diagnóstico por imagen , Articulación de la Rodilla/diagnóstico por imagen , Agua
10.
Magn Reson Med ; 90(5): 2052-2070, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37427449

RESUMEN

PURPOSE: To develop a method for building MRI reconstruction neural networks robust to changes in signal-to-noise ratio (SNR) and trainable with a limited number of fully sampled scans. METHODS: We propose Noise2Recon, a consistency training method for SNR-robust accelerated MRI reconstruction that can use both fully sampled (labeled) and undersampled (unlabeled) scans. Noise2Recon uses unlabeled data by enforcing consistency between model reconstructions of undersampled scans and their noise-augmented counterparts. Noise2Recon was compared to compressed sensing and both supervised and self-supervised deep learning baselines. Experiments were conducted using retrospectively accelerated data from the mridata three-dimensional fast-spin-echo knee and two-dimensional fastMRI brain datasets. All methods were evaluated in label-limited settings and among out-of-distribution (OOD) shifts, including changes in SNR, acceleration factors, and datasets. An extensive ablation study was conducted to characterize the sensitivity of Noise2Recon to hyperparameter choices. RESULTS: In label-limited settings, Noise2Recon achieved better structural similarity, peak signal-to-noise ratio, and normalized-RMS error than all baselines and matched performance of supervised models, which were trained with 14 × $$ 14\times $$ more fully sampled scans. Noise2Recon outperformed all baselines, including state-of-the-art fine-tuning and augmentation techniques, among low-SNR scans and when generalizing to OOD acceleration factors. Augmentation extent and loss weighting hyperparameters had negligible impact on Noise2Recon compared to supervised methods, which may indicate increased training stability. CONCLUSION: Noise2Recon is a label-efficient reconstruction method that is robust to distribution shifts, such as changes in SNR, acceleration factors, and others, with limited or no fully sampled training data.


Asunto(s)
Aprendizaje Profundo , Procesamiento de Imagen Asistido por Computador , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Relación Señal-Ruido , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Aprendizaje Automático Supervisado
11.
J Magn Reson Imaging ; 2023 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-38156716

RESUMEN

With a substantial growth in the use of musculoskeletal MRI, there has been a growing need to improve MRI workflow, and faster imaging has been suggested as one of the solutions for a more efficient examination process. Consequently, there have been considerable advances in accelerated MRI scanning methods. This article aims to review the basic principles and applications of accelerated musculoskeletal MRI techniques including widely used conventional acceleration methods, more advanced deep learning-based techniques, and new approaches to reduce scan time. Specifically, conventional accelerated MRI techniques, including parallel imaging, compressed sensing, and simultaneous multislice imaging, and deep learning-based accelerated MRI techniques, including undersampled MR image reconstruction, super-resolution imaging, artifact correction, and generation of unacquired contrast images, are discussed. Finally, new approaches to reduce scan time, including synthetic MRI, novel sequences, and new coil setups and designs, are also reviewed. We believe that a deep understanding of these fast MRI techniques and proper use of combined acceleration methods will synergistically improve scan time and MRI workflow in daily practice. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: Stage 1.

12.
J Magn Reson Imaging ; 57(4): 1029-1039, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-35852498

RESUMEN

BACKGROUND: Deep learning (DL)-based automatic segmentation models can expedite manual segmentation yet require resource-intensive fine-tuning before deployment on new datasets. The generalizability of DL methods to new datasets without fine-tuning is not well characterized. PURPOSE: Evaluate the generalizability of DL-based models by deploying pretrained models on independent datasets varying by MR scanner, acquisition parameters, and subject population. STUDY TYPE: Retrospective based on prospectively acquired data. POPULATION: Overall test dataset: 59 subjects (26 females); Study 1: 5 healthy subjects (zero females), Study 2: 8 healthy subjects (eight females), Study 3: 10 subjects with osteoarthritis (eight females), Study 4: 36 subjects with various knee pathology (10 females). FIELD STRENGTH/SEQUENCE: A 3-T, quantitative double-echo steady state (qDESS). ASSESSMENT: Four annotators manually segmented knee cartilage. Each reader segmented one of four qDESS datasets in the test dataset. Two DL models, one trained on qDESS data and another on Osteoarthritis Initiative (OAI)-DESS data, were assessed. Manual and automatic segmentations were compared by quantifying variations in segmentation accuracy, volume, and T2 relaxation times for superficial and deep cartilage. STATISTICAL TESTS: Dice similarity coefficient (DSC) for segmentation accuracy. Lin's concordance correlation coefficient (CCC), Wilcoxon rank-sum tests, root-mean-squared error-coefficient-of-variation to quantify manual vs. automatic T2 and volume variations. Bland-Altman plots for manual vs. automatic T2 agreement. A P value < 0.05 was considered statistically significant. RESULTS: DSCs for the qDESS-trained model, 0.79-0.93, were higher than those for the OAI-DESS-trained model, 0.59-0.79. T2 and volume CCCs for the qDESS-trained model, 0.75-0.98 and 0.47-0.95, were higher than respective CCCs for the OAI-DESS-trained model, 0.35-0.90 and 0.13-0.84. Bland-Altman 95% limits of agreement for superficial and deep cartilage T2 were lower for the qDESS-trained model, ±2.4 msec and ±4.0 msec, than the OAI-DESS-trained model, ±4.4 msec and ±5.2 msec. DATA CONCLUSION: The qDESS-trained model may generalize well to independent qDESS datasets regardless of MR scanner, acquisition parameters, and subject population. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 1.


Asunto(s)
Cartílago Articular , Aprendizaje Profundo , Osteoartritis de la Rodilla , Femenino , Humanos , Estudios Retrospectivos , Cartílago Articular/patología , Imagen por Resonancia Magnética/métodos , Algoritmos , Osteoartritis de la Rodilla/patología
13.
Radiographics ; 43(6): e220177, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37261964

RESUMEN

Patellofemoral pain and instability are common indications for imaging that are encountered in everyday practice. The authors comprehensively review key aspects of patellofemoral instability pertinent to radiologists that can be seen before the onset of osteoarthritis, highlighting the anatomy, clinical evaluation, diagnostic imaging, and treatment. Regarding the anatomy, the medial patellofemoral ligament (MPFL) is the primary static soft-tissue restraint to lateral patellar displacement and is commonly reconstructed surgically in patients with MPFL dysfunction and patellar instability. Osteoarticular abnormalities that predispose individuals to patellar instability include patellar malalignment, trochlear dysplasia, and tibial tubercle lateralization. Clinically, patients with patellar instability may be divided into two broad groups with imaging findings that sometimes overlap: patients with a history of overt patellar instability after a traumatic event (eg, dislocation, subluxation) and patients without such a history. In terms of imaging, radiography is generally the initial examination of choice, and MRI is the most common cross-sectional examination performed preoperatively. For all imaging techniques, there has been a proliferation of published radiologic measurement methods. The authors summarize the most common validated measurements for patellar malalignment, trochlear dysplasia, and tibial tubercle lateralization. Given that static imaging is inherently limited in the evaluation of patellar motion, dynamic imaging with US, CT, or MRI may be requested by some surgeons. The primary treatment strategy for patellofemoral pain is conservative. Surgical treatment options include MPFL reconstruction with or without osseous corrections such as trochleoplasty and tibial tubercle osteotomy. Postoperative complications evaluated at imaging include patellar fracture, graft failure, graft malposition, and medial patellar subluxation. ©RSNA, 2023 Quiz questions for this article are available in the supplemental material.


Asunto(s)
Luxaciones Articulares , Inestabilidad de la Articulación , Luxación de la Rótula , Articulación Patelofemoral , Síndrome de Dolor Patelofemoral , Humanos , Luxación de la Rótula/diagnóstico por imagen , Luxación de la Rótula/cirugía , Luxación de la Rótula/complicaciones , Articulación Patelofemoral/diagnóstico por imagen , Articulación Patelofemoral/cirugía , Estudios Transversales , Síndrome de Dolor Patelofemoral/complicaciones , Ligamentos Articulares/cirugía
14.
MAGMA ; 36(5): 711-724, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37142852

RESUMEN

PURPOSE: [Formula: see text] mapping is a powerful tool for studying osteoarthritis (OA) changes and bilateral imaging may be useful in investigating the role of between-knee asymmetry in OA onset and progression. The quantitative double-echo in steady-state (qDESS) can provide fast simultaneous bilateral knee [Formula: see text] and high-resolution morphometry for cartilage and meniscus. The qDESS uses an analytical signal model to compute [Formula: see text] relaxometry maps, which require knowledge of the flip angle (FA). In the presence of [Formula: see text] inhomogeneities, inconsistencies between the nominal and actual FA can affect the accuracy of [Formula: see text] measurements. We propose a pixel-wise [Formula: see text] correction method for qDESS [Formula: see text] mapping exploiting an auxiliary [Formula: see text] map to compute the actual FA used in the model. METHODS: The technique was validated in a phantom and in vivo with simultaneous bilateral knee imaging. [Formula: see text] measurements of femoral cartilage (FC) of both knees of six healthy participants were repeated longitudinally to investigate the association between [Formula: see text] variation and [Formula: see text]. RESULTS: The results showed that applying the [Formula: see text] correction mitigated [Formula: see text] variations that were driven by [Formula: see text] inhomogeneities. Specifically, [Formula: see text] left-right symmetry increased following the [Formula: see text] correction ([Formula: see text] = 0.74 > [Formula: see text] = 0.69). Without the [Formula: see text] correction, [Formula: see text] values showed a linear dependence with [Formula: see text]. The linear coefficient decreased using the [Formula: see text] correction (from 24.3 ± 1.6 ms to 4.1 ± 1.8) and the correlation was not statistically significant after the application of the Bonferroni correction (p value > 0.01). CONCLUSION: The study showed that [Formula: see text] correction could mitigate variations driven by the sensitivity of the qDESS [Formula: see text] mapping method to [Formula: see text], therefore, increasing the sensitivity to detect real biological changes. The proposed method may improve the robustness of bilateral qDESS [Formula: see text] mapping, allowing for an accurate and more efficient evaluation of OA pathways and pathophysiology through longitudinal and cross-sectional studies.


Asunto(s)
Articulación de la Rodilla , Imagen por Resonancia Magnética , Humanos , Estudios Transversales , Imagen por Resonancia Magnética/métodos , Articulación de la Rodilla/diagnóstico por imagen , Imagenología Tridimensional , Fantasmas de Imagen
15.
J Oncol Pharm Pract ; 29(7): 1667-1672, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36529895

RESUMEN

BACKGROUND: Good clinical practices and strict vigilance are needed, especially for patients receiving chemotherapy. Regular audits using a specially developed tool need to be conducted in the oncology wards to identify lapses in the use of chemotherapy drugs. METHODOLOGY: Observational study was conducted in the adult and paediatric oncology inpatient settings in an Indian tertiary care hospital for a period of 2.5 years. It was an audit of case files of chemotherapy patients for their drug prescriptions, medication reconciliation records and adverse drug reports. Data was presented as frequencies and percentages. RESULTS: 1.3% medication errors and 0.23% adverse drug reactions were reported during the study period. Majority were transcription (38%) and drug reconstitution errors (29%) and were either in the near-miss or no-harm category. CONCLUSION: Medication errors were found in the oncology wards, but due to the vigilance of clinical pharmacists, none of the patients were harmed as a consequence of these errors.


Asunto(s)
Neoplasias , Farmacéuticos , Adulto , Niño , Humanos , Pacientes Internos , Errores de Medicación , Conciliación de Medicamentos , Neoplasias/tratamiento farmacológico
16.
Cereb Cortex ; 31(1): 463-482, 2021 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-32887984

RESUMEN

Accurate and automated reconstruction of the in vivo human cerebral cortical surface from anatomical magnetic resonance (MR) images facilitates the quantitative analysis of cortical structure. Anatomical MR images with sub-millimeter isotropic spatial resolution improve the accuracy of cortical surface and thickness estimation compared to the standard 1-millimeter isotropic resolution. Nonetheless, sub-millimeter resolution acquisitions require averaging multiple repetitions to achieve sufficient signal-to-noise ratio and are therefore long and potentially vulnerable to subject motion. We address this challenge by synthesizing sub-millimeter resolution images from standard 1-millimeter isotropic resolution images using a data-driven supervised machine learning-based super-resolution approach achieved via a deep convolutional neural network. We systematically characterize our approach using a large-scale simulated dataset and demonstrate its efficacy in empirical data. The super-resolution data provide improved cortical surfaces similar to those obtained from native sub-millimeter resolution data. The whole-brain mean absolute discrepancy in cortical surface positioning and thickness estimation is below 100 µm at the single-subject level and below 50 µm at the group level for the simulated data, and below 200 µm at the single-subject level and below 100 µm at the group level for the empirical data, making the accuracy of cortical surfaces derived from super-resolution sufficient for most applications.


Asunto(s)
Corteza Cerebral/patología , Procesamiento de Imagen Asistido por Computador , Redes Neurales de la Computación , Encéfalo/patología , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Relación Señal-Ruido
17.
Skeletal Radiol ; 51(3): 513-524, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34268590

RESUMEN

Sarcopenia is defined as the loss of muscle mass, strength, and function. Increasing evidence shows that sarcopenia is common in patients with rheumatic disorders. Although sarcopenia can be diagnosed using bioelectrical impedance analysis or DXA, increasingly it is diagnosed using CT, MRI, and ultrasound. In rheumatic patients, CT and MRI allow "opportunistic" measurement of body composition, including surrogate markers of sarcopenia, from studies obtained during routine patient care. Recognition of sarcopenia is important in rheumatic patients because sarcopenia can be associated with disease progression and poor outcomes. This article reviews how opportunistic evaluation of sarcopenia in rheumatic patients can be accomplished and potentially contribute to improved patient care.


Asunto(s)
Sarcopenia , Composición Corporal , Humanos , Músculo Esquelético/patología , Radiólogos , Reumatólogos , Sarcopenia/diagnóstico por imagen
18.
J Magn Reson Imaging ; 54(2): 357-371, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-32830874

RESUMEN

Artificial intelligence algorithms based on principles of deep learning (DL) have made a large impact on the acquisition, reconstruction, and interpretation of MRI data. Despite the large number of retrospective studies using DL, there are fewer applications of DL in the clinic on a routine basis. To address this large translational gap, we review the recent publications to determine three major use cases that DL can have in MRI, namely, that of model-free image synthesis, model-based image reconstruction, and image or pixel-level classification. For each of these three areas, we provide a framework for important considerations that consist of appropriate model training paradigms, evaluation of model robustness, downstream clinical utility, opportunities for future advances, as well recommendations for best current practices. We draw inspiration for this framework from advances in computer vision in natural imaging as well as additional healthcare fields. We further emphasize the need for reproducibility of research studies through the sharing of datasets and software. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY STAGE: 2.


Asunto(s)
Inteligencia Artificial , Aprendizaje Profundo , Algoritmos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Redes Neurales de la Computación , Estudios Prospectivos , Reproducibilidad de los Resultados , Estudios Retrospectivos
19.
Eur Radiol ; 31(12): 9369-9379, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33993332

RESUMEN

OBJECTIVES: To determine whether synovitis graded by radiologists using hybrid quantitative double-echo in steady-state (qDESS) images can be utilized as a non-contrast approach to assess synovitis in the knee, compared against the reference standard of contrast-enhanced MRI (CE-MRI). METHODS: Twenty-two knees (11 subjects) with moderate to severe osteoarthritis (OA) were scanned using CE-MRI, qDESS with a high diffusion weighting (qDESSHigh), and qDESS with a low diffusion weighting (qDESSLow). Four radiologists graded the overall impression of synovitis, their diagnostic confidence, and regional grading of synovitis severity at four sites (suprapatellar pouch, intercondylar notch, and medial and lateral peripatellar recesses) in the knee using a 4-point scale. Agreement between CE-MRI and qDESS, inter-rater agreement, and intra-rater agreement were assessed using a linearly weighted Gwet's AC2. RESULTS: Good agreement was seen between CE-MRI and both qDESSLow (AC2 = 0.74) and qDESSHigh (AC2 = 0.66) for the overall impression of synovitis, but both qDESS sequences tended to underestimate the severity of synovitis compared to CE-MRI. Good inter-rater agreement was seen for both qDESS sequences (AC2 = 0.74 for qDESSLow, AC2 = 0.64 for qDESSHigh), and good intra-rater agreement was seen for both sequences as well (qDESSLow AC2 = 0.78, qDESSHigh AC2 = 0.80). Diagnostic confidence was moderate to high for qDESSLow (mean = 2.36) and slightly less than moderate for qDESSHigh (mean = 1.86), compared to mostly high confidence for CE-MRI (mean = 2.73). CONCLUSIONS: qDESS shows potential as an alternative MRI technique for assessing the severity of synovitis without the use of a gadolinium-based contrast agent. KEY POINTS: The use of the quantitative double-echo in steady-state (qDESS) sequence for synovitis assessment does not require the use of a gadolinium-based contrast agent. Preliminary results found that low diffusion-weighted qDESS (qDESSLow) shows good agreement to contrast-enhanced MRI for characterization of the severity of synovitis, with a relative bias towards underestimation of severity. Preliminary results also found that qDESSLow shows good inter- and intra-rater agreement for the depiction of synovitis, particularly for readers experienced with the sequence.


Asunto(s)
Osteoartritis de la Rodilla , Sinovitis , Medios de Contraste , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Imagen por Resonancia Magnética , Osteoartritis de la Rodilla/diagnóstico por imagen , Membrana Sinovial , Sinovitis/diagnóstico por imagen
20.
AJR Am J Roentgenol ; 216(6): 1614-1625, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-32755384

RESUMEN

BACKGROUND. Potential approaches for abbreviated knee MRI, including prospective acceleration with deep learning, have achieved limited clinical implementation. OBJECTIVE. The objective of this study was to evaluate the interreader agreement between conventional knee MRI and a 5-minute 3D quantitative double-echo steady-state (qDESS) sequence with automatic T2 mapping and deep learning super-resolutionaugmentation and to compare the diagnostic performance of the two methods regarding findings from arthroscopic surgery. METHODS. Fifty-one patients with knee pain underwent knee MRI that included an additional 3D qDESS sequence with automatic T2 mapping. Fourier interpolation was followed by prospective deep learning super resolution to enhance qDESS slice resolution twofold. A musculoskeletal radiologist and a radiology resident performed independent retrospective evaluations of articular cartilage, menisci, ligaments, bones, extensor mechanism, and synovium using conventional MRI. Following a 2-month washout period, readers reviewed qDESS images alone followed by qDESS with the automatic T2 maps. Interreader agreement between conventional MRI and qDESS was computed using percentage agreement and Cohen kappa. The sensitivity and specificity of conventional MRI, qDESS alone, and qDESS plus T2 mapping were compared with arthroscopic findings using exact McNemar tests. RESULTS. Conventional MRI and qDESS showed 92% agreement in evaluating all tissues. Kappa was 0.79 (95% CI, 0.76-0.81) across all imaging findings. In 43 patients who underwent arthroscopy, sensitivity and specificity were not significantly different (p = .23 to > .99) between conventional MRI (sensitivity, 58-93%; specificity, 27-87%) and qDESS alone (sensitivity, 54-90%; specificity, 23-91%) for cartilage, menisci, ligaments, and synovium. For grade 1 cartilage lesions, sensitivity and specificity were 33% and 56%, respectively, for conventional MRI; 23% and 53% for qDESS (p = .81); and 46% and 39% for qDESS with T2 mapping (p = .80). For grade 2A lesions, values were 27% and 53% for conventional MRI, 26% and 52% for qDESS (p = .02), and 58% and 40% for qDESS with T2 mapping (p < .001). CONCLUSION. The qDESS method prospectively augmented with deep learning showed strong interreader agreement with conventional knee MRI and near-equivalent diagnostic performance regarding arthroscopy. The ability of qDESS to automatically generate T2 maps increases sensitivity for cartilage abnormalities. CLINICAL IMPACT. Using prospective artificial intelligence to enhance qDESS image quality may facilitate an abbreviated knee MRI protocol while generating quantitative T2 maps.


Asunto(s)
Medios de Contraste , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Traumatismos de la Rodilla/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Inteligencia Artificial , Estudios de Evaluación como Asunto , Femenino , Humanos , Imagenología Tridimensional/métodos , Articulación de la Rodilla/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tiempo , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA