Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Xray Sci Technol ; 32(3): 783-795, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38457140

RESUMEN

BACKGROUND: The study aimed to investigate anatomical changes in the neck region and evaluate their impact on dose distribution in patients with nasopharyngeal carcinoma (NPC) undergoing intensity modulated radiation therapy (IMRT). Additionally, the study sought to determine the optimal time for replanning during the course of treatment. METHODS: Twenty patients diagnosed with NPC underwent IMRT, with weekly pretreatment kV fan beam computed tomography (FBCT) scans in the treatment room. Metastasized lymph nodes in the neck region and organs at risk (OARs) were redelineation using the images from the FBCT scans. Subsequently, the original treatment plan (PLAN0) was replicated to each FBCT scan to generate new plans labeled as PLAN 1-6. The dose-volume histograms (DVH) of the new plans and the original plan were compared. One-way repeated measure ANOVA was utilized to establish threshold(s) at various time points. The presence of such threshold(s) would signify significant change(s), suggesting the need for replanning. RESULTS: Progressive volume reductions were observed over time in the neck region, the gross target volume for metastatic lymph nodes (GTVnd), as well as the submandibular glands and parotids. Compared to PLAN0, the mean dose (Dmean) of GTVnd-L significantly increased in PLAN5, while the minimum dose covering 95% of the volume (D95%) of PGTVnd-L showed a significant decrease from PLAN3 to PLAN6. Similarly, the Dmean of GTVnd-R significantly increased from PLAN4 to PLAN6, whereas the D95% of PGTVnd-R exhibited a significant decrease during the same period. Furthermore, the dose of bilateral parotid glands, bilateral submandibular glands, brainstem and spinal cord was gradually increased in the middle and late period of treatment. CONCLUSION: Significant anatomical and dosimetric changes were noted in both the target volumes and OARs. Considering the thresholds identified, it is imperative to undertake replanning at approximately 20 fractions. This measure ensures the delivery of adequate doses to target volumes while mitigating the risk of overdosing on OARs.


Asunto(s)
Carcinoma Nasofaríngeo , Neoplasias Nasofaríngeas , Cuello , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada , Tomografía Computarizada por Rayos X , Humanos , Neoplasias Nasofaríngeas/radioterapia , Neoplasias Nasofaríngeas/diagnóstico por imagen , Neoplasias Nasofaríngeas/patología , Carcinoma Nasofaríngeo/radioterapia , Carcinoma Nasofaríngeo/diagnóstico por imagen , Cuello/diagnóstico por imagen , Masculino , Radioterapia de Intensidad Modulada/métodos , Persona de Mediana Edad , Femenino , Adulto , Tomografía Computarizada por Rayos X/métodos , Carcinoma/diagnóstico por imagen , Carcinoma/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Órganos en Riesgo/efectos de la radiación , Órganos en Riesgo/diagnóstico por imagen , Radiometría/métodos
2.
Technol Cancer Res Treat ; 23: 15330338241229367, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38297814

RESUMEN

Objective: To investigate the dosimetric effects of using individualized silicone rubber (SR) bolus on the target area and organs at risk (OARs) during postmastectomy radiotherapy (PMRT), as well as evaluate skin acute radiation dermatitis (ARD). Methods: A retrospective study was performed on 30 patients with breast cancer. Each patient was prepared with an individualized SR bolus of 3 mm thickness. Fan-beam computed tomography (FBCT) was performed at the first and second fractions, and then once a week for a total of 5 times. Dosimetric metrics such as homogeneity index (HI), conformity index (CI), skin dose (SD), and OARs including the heart, lungs, and spinal cord were compared between the original plan and the FBCTs. The acute side effects were recorded. Results: In targets' dosimetric metrics, there were no significant differences in Dmean and V105% between planning computed tomography (CT) and actual treatments (P > .05), while the differences in D95%, V95%, HI, and CI were statistically significant (P < .05). In OARs, there were no significant differences between the Dmean, V5, and V20 of the affected lung, V5 of the heart and Dmax of the spinal cord (P > .05) except the V30 of affected lung, which was slightly lower than the planning CT (P < .05). In SD, both Dmax and Dmean in actual treatments were increased than plan A, and the difference was statistically significant (P < .05), while the skin-V20 and skin-V30 has no difference. Among the 30 patients, only one patient had no skin ARD, and 5 patients developed ARD of grade 2, while the remaining 24 patients were grade 1. Conclusion: The OR bolus showed good anastomoses and high interfraction reproducibility with the chest wall, and did not cause deformation during irradiation. It ensured accurate dose delivery of the target and OARs during the treatment, which may increase SD by over 101%. In this study, no cases of grade 3 skin ARD were observed. However, the potential of using OR bolus to reduce grade 1 and 2 skin ARD warrants further investigation with a larger sample size.


Asunto(s)
Neoplasias de la Mama , Dermatitis , Radioterapia de Intensidad Modulada , Humanos , Femenino , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/cirugía , Elastómeros de Silicona , Planificación de la Radioterapia Asistida por Computador/métodos , Dosificación Radioterapéutica , Estudios Retrospectivos , Reproducibilidad de los Resultados , Mastectomía/efectos adversos , Radioterapia de Intensidad Modulada/efectos adversos , Radioterapia de Intensidad Modulada/métodos , Tomografía Computarizada por Rayos X , Dermatitis/cirugía , Órganos en Riesgo/efectos de la radiación
3.
Med Phys ; 49(10): 6728-6738, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35959736

RESUMEN

PURPOSE: Ultra-high dose rate FLASH irradiation (FLASH-IR) has been shown to cause less normal tissue damage compared with conventional irradiation (CONV-IR), this is known as the "FLASH effect." It has attracted immense research interest because its underlying mechanism is scarcely known. The purpose of this study was to determine whether FLASH-IR and CONV-IR induce differential inflammatory cytokine expression using a modified clinical linac. MATERIALS AND METHODS: An Elekta Synergy linac was used to deliver 6 MeV CONV-IR and modified to deliver FLASH-IR. Female FvB mice were randomly assigned to three different groups: a non-irradiated control, CONV-IR, or FLASH-IR. The FLASH-IR beam was produced by single pulses repeated manually with a 20-s interval (Strategy 1), or single-trigger multiple pulses with a 10 ms interval (Strategy 2). Mice were immobilized in the prone position in a custom-designed applicator with Gafchromic films positioned under the body. The prescribed doses for the mice were 6 to 18 Gy and verified using Gafchromic films. Cytokine expression of three pro-inflammatory cytokines (tumor necrosis factor-α [TNF-α], interferon-γ [IFN-γ], interleukin-6 [IL-6]) and one anti-inflammatory cytokine (IL-10) in serum samples and skin tissue were examined within 1 month post-IR. RESULTS: The modified linac delivered radiation at an intra-pulse dose rate of around 1 × 106 Gy/s and a dose per pulse over 2 Gy at a source-to-surface distance (SSD) of 13 to 15 cm. The achieved dose coverage was 90%-105% of the maximum dose within -20 to 20 mm in the X direction and 95% within -30 to 30 mm in the Y direction. The absolute deviations between the prescribed dose and the actual dose were 2.21%, 6.04%, 2.09%, and 2.73% for 6, 9, 12, and 15 Gy as measured by EBT3 films, respectively; and 4.00%, 4.49%, and 2.30% for 10, 14, and 18 Gy as measured by the EBT XD films, respectively. The reductions in the CONV-IR versus the FLASH-IR group were 4.89%, 10.28%, -7.8%, and -22.17% for TNF-α, IFN-γ, IL-6, and IL-10 in the serum on D6, respectively; 37.26%, 67.16%, 56.68%, and -18.95% in the serum on D31, respectively; and 62.67%, 35.65%, 37.75%, and -12.20% for TNF-α, IFN-γ, IL-6, and IL-10 in the skin tissue, respectively. CONCLUSIONS: Ultra-high dose rate electron FLASH caused lower pro-inflammatory cytokine levels in serum and skin tissue which might mediate differential tissue damage between FLASH-IR and CONV-IR.


Asunto(s)
Interleucina-10 , Factor de Necrosis Tumoral alfa , Animales , Electrones , Femenino , Interferón gamma , Interleucina-6 , Ratones
4.
Med Dosim ; 45(1): 46-51, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31213401

RESUMEN

Nasopharyngeal adenoid cystic carcinoma is a rare neoplasm characterized by strong local invasiveness and a higher tendency to relapse. Because of the rare cases, there is a little consensus on treatment. We report a case of T3N0 NACC with a positive resection margin treated with postoperative adjuvant radiotherapy. MRI reexamination indicated suspected tumor progression during the course of radiotherapy. In order to improve local control, late-course accelerated hyperfractionated intensity-modulated radiotherapy (LCAF-IMRT) was performed to escalate total dose, which achieved good local control with no significant late toxicity.


Asunto(s)
Carcinoma Adenoide Quístico/radioterapia , Fraccionamiento de la Dosis de Radiación , Neoplasias Nasofaríngeas/radioterapia , Radioterapia de Intensidad Modulada/métodos , Adulto , Humanos , Masculino , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA