Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 94
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Lancet ; 403(10435): 1451-1459, 2024 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-38552656

RESUMEN

BACKGROUND: Surgery remains the only recommended intervention for patients with native aortic regurgitation. A transcatheter therapy to treat patients at high risk for mortality and complications with surgical aortic valve replacement represents an unmet need. Commercial transcatheter heart valves in pure aortic regurgitation are hampered by unacceptable rates of embolisation and paravalvular regurgitation. The Trilogy transcatheter heart valve (JenaValve Technology, Irvine, CA, USA) provides a treatment option for these patients. We report outcomes with transfemoral transcatheter aortic valve implantation (TAVI) in patients with pure aortic regurgitation using this dedicated transcatheter heart valve. METHODS: The ALIGN-AR trial is a prospective, multicentre, single-arm study. We recruited symptomatic patients (aged ≥18 years) with moderate-to-severe or severe aortic regurgitation at high risk for mortality and complications after surgical aortic valve replacement at 20 US sites for treatment with the Trilogy transcatheter heart valve. The 30-day composite primary safety endpoint was compared for non-inferiority with a prespecified performance goal of 40·5%. The primary efficacy endpoint was 1-year all-cause mortality compared for non-inferiority with a performance goal of 25%. This trial is registered with ClinicalTrials.gov, NCT04415047, and is ongoing. FINDINGS: Between June 8, 2018, and Aug 29, 2022, we screened 346 patients. We excluded 166 (48%) patients and enrolled 180 (52%) patients with symptomatic aortic regurgitation deemed high risk by the heart team and independent screening committee assessments. The mean age of the study population was 75·5 years (SD 10·8), and 85 (47%) were female, 95 (53%) were male, and 131 (73%) were White. Technical success was achieved in 171 (95%) patients. At 30 days, four (2%) deaths, two (1%) disabling strokes, and two (1%) non-disabling strokes occurred. Using standard Valve Academic Research Consortium-2 definitions, the primary safety endpoint was achieved, with events occurring in 48 (27% [97·5% CI 19·2-34·0]) patients (pnon-inferiority<0·0001), with new pacemaker implantation in 36 (24%) patients. The primary efficacy endpoint was achieved, with mortality in 14 (7·8% [3·3-12·3]) patients at 1 year (pnon-inferiority<0·0001). INTERPRETATION: This study shows the safety and effectiveness of treating native aortic regurgitation using a dedicated transcatheter heart valve to treat patients with symptomatic moderate-to-severe or severe aortic regurgitation who are at high risk for mortality or complications after surgical aortic valve replacement. The observed short-term clinical and haemodynamic outcomes are promising as are signs of left ventricular remodelling, but long-term follow-up is necessary. FUNDING: JenaValve Technology.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
2.
Eur Heart J ; 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38747561

RESUMEN

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all (100%; 95% confidence interval [CI] 94-100.0%, p<0.001) patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 (98.3%; 95% CI [91.1-100%]) patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1-99.0%). Within 90 days, freedom from mortality was 95% (95% CI 86.1-99.0%]), without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favorable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.

3.
Catheter Cardiovasc Interv ; 101(4): 756-763, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36748804

RESUMEN

BACKGROUND: TandemHeart has been demonstrated to improve hemodynamic and metabolic complications in cardiogenic shock (CS). Contemporary outcomes have not been reported. OBJECTIVES: To evaluate the outcomes of the TandemHeart (LivaNova) in contemporary real-world use. METHODS: We analyzed baseline characteristics, hemodynamic changes, and outcomes of all patients treated with TandemHeart who were enrolled in the THEME registry, a multicenter, prospective, observational study. RESULTS: Between May 2015 and June 2019, 50 patients underwent implantation of the TandemHeart device. 22% of patients had TandemHeart implanted within 12 h, 32% within 24 h, and 52% within 48 h of CS diagnosis. Cardiac index (CI) was significantly improved 24 h after implantation (median change 1.0, interquartile range (IQR) (0.5-1.4 L/min/m2 ). In survivors, there was a significant improvement in CI (1.0, IQR (0.5-2.25 L/min/m2 ) and lactate clearance -2.3 (-5.0 to -0.7 mmol/L). The 30-day and 180-day survival were 74% (95% confidence interval: 60%-85%) and 66% (95% confidence interval: 51%-79%), respectively. Survival was similarly high in those in whom TandemHeart has been used as a bridge to surgery (85% 180-day survival). CONCLUSION: In a contemporary cohort of patients presenting in CS, the use of TandemHeart is associated with a 74% 30-day survival and a 66% 180-day survival.


Asunto(s)
Corazón Auxiliar , Choque Cardiogénico , Humanos , Choque Cardiogénico/terapia , Estudios Prospectivos , Corazón Auxiliar/efectos adversos , Resultado del Tratamiento , Sistema de Registros
4.
N Engl J Med ; 380(18): 1706-1715, 2019 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-30883053

RESUMEN

BACKGROUND: Transcatheter aortic-valve replacement (TAVR) is an alternative to surgery in patients with severe aortic stenosis who are at increased risk for death from surgery; less is known about TAVR in low-risk patients. METHODS: We performed a randomized noninferiority trial in which TAVR with a self-expanding supraannular bioprosthesis was compared with surgical aortic-valve replacement in patients who had severe aortic stenosis and were at low surgical risk. When 850 patients had reached 12-month follow-up, we analyzed data regarding the primary end point, a composite of death or disabling stroke at 24 months, using Bayesian methods. RESULTS: Of the 1468 patients who underwent randomization, an attempted TAVR or surgical procedure was performed in 1403. The patients' mean age was 74 years. The 24-month estimated incidence of the primary end point was 5.3% in the TAVR group and 6.7% in the surgery group (difference, -1.4 percentage points; 95% Bayesian credible interval for difference, -4.9 to 2.1; posterior probability of noninferiority >0.999). At 30 days, patients who had undergone TAVR, as compared with surgery, had a lower incidence of disabling stroke (0.5% vs. 1.7%), bleeding complications (2.4% vs. 7.5%), acute kidney injury (0.9% vs. 2.8%), and atrial fibrillation (7.7% vs. 35.4%) and a higher incidence of moderate or severe aortic regurgitation (3.5% vs. 0.5%) and pacemaker implantation (17.4% vs. 6.1%). At 12 months, patients in the TAVR group had lower aortic-valve gradients than those in the surgery group (8.6 mm Hg vs. 11.2 mm Hg) and larger effective orifice areas (2.3 cm2 vs. 2.0 cm2). CONCLUSIONS: In patients with severe aortic stenosis who were at low surgical risk, TAVR with a self-expanding supraannular bioprosthesis was noninferior to surgery with respect to the composite end point of death or disabling stroke at 24 months. (Funded by Medtronic; ClinicalTrials.gov number, NCT02701283.).


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Accidente Cerebrovascular/etiología , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/mortalidad , Fibrilación Atrial/etiología , Teorema de Bayes , Ecocardiografía , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Estimación de Kaplan-Meier , Tiempo de Internación , Masculino , Complicaciones Posoperatorias/epidemiología , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
5.
N Engl J Med ; 376(14): 1321-1331, 2017 04 06.
Artículo en Inglés | MEDLINE | ID: mdl-28304219

RESUMEN

BACKGROUND: Although transcatheter aortic-valve replacement (TAVR) is an accepted alternative to surgery in patients with severe aortic stenosis who are at high surgical risk, less is known about comparative outcomes among patients with aortic stenosis who are at intermediate surgical risk. METHODS: We evaluated the clinical outcomes in intermediate-risk patients with severe, symptomatic aortic stenosis in a randomized trial comparing TAVR (performed with the use of a self-expanding prosthesis) with surgical aortic-valve replacement. The primary end point was a composite of death from any cause or disabling stroke at 24 months in patients undergoing attempted aortic-valve replacement. We used Bayesian analytical methods (with a margin of 0.07) to evaluate the noninferiority of TAVR as compared with surgical valve replacement. RESULTS: A total of 1746 patients underwent randomization at 87 centers. Of these patients, 1660 underwent an attempted TAVR or surgical procedure. The mean (±SD) age of the patients was 79.8±6.2 years, and all were at intermediate risk for surgery (Society of Thoracic Surgeons Predicted Risk of Mortality, 4.5±1.6%). At 24 months, the estimated incidence of the primary end point was 12.6% in the TAVR group and 14.0% in the surgery group (95% credible interval [Bayesian analysis] for difference, -5.2 to 2.3%; posterior probability of noninferiority, >0.999). Surgery was associated with higher rates of acute kidney injury, atrial fibrillation, and transfusion requirements, whereas TAVR had higher rates of residual aortic regurgitation and need for pacemaker implantation. TAVR resulted in lower mean gradients and larger aortic-valve areas than surgery. Structural valve deterioration at 24 months did not occur in either group. CONCLUSIONS: TAVR was a noninferior alternative to surgery in patients with severe aortic stenosis at intermediate surgical risk, with a different pattern of adverse events associated with each procedure. (Funded by Medtronic; SURTAVI ClinicalTrials.gov number, NCT01586910 .).


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Teorema de Bayes , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Complicaciones Posoperatorias , Factores de Riesgo , Índice de Severidad de la Enfermedad , Accidente Cerebrovascular/epidemiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
6.
J Cardiovasc Electrophysiol ; 31(8): 1901-1903, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32445421

RESUMEN

During coronavirus disease-2019 (COVID-19) pandemic, there continues to be a need to utilize cardiac catheterization and electrophysiology laboratories for emergent and urgent procedures. Per infection prevention guidelines and hospital codes, catheterization and electrophysiology laboratories are usually built as positive-pressure ventilation rooms to minimize the infection risk. However, patients with highly transmissible airborne diseases such as COVID-19 are best caredfor in negative ventilation rooms to minimize the risk of transmission. From a mechanical and engineering perspective, positive-pressure ventilation rooms cannot be readily converted to negative-pressure ventilation rooms. In this report, we describe a novel, quick, readily implantable, and resource-friendly approach on how to secure air quality in catheterization and electrophysiology laboratories by converting a positive-pressure ventilation room to a two-zone negative ventilation system to minimize the risk of transmission.


Asunto(s)
COVID-19/prevención & control , Cateterismo Cardíaco , Control de Infecciones/normas , Ventilación/instrumentación , Presión del Aire , Ambiente Controlado , Arquitectura y Construcción de Hospitales , Humanos , Pandemias , SARS-CoV-2
7.
Catheter Cardiovasc Interv ; 95(5): 1051-1056, 2020 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-31478304

RESUMEN

OBJECTIVES: This multicenter retrospective study of the initial U.S. experience evaluated the safety and efficacy of temporary cardiac pacing with the Tempo® Temporary Pacing Lead. BACKGROUND: Despite increasing use of temporary cardiac pacing with the rapid growth of structural heart procedures, temporary pacing leads have not significantly improved. The Tempo lead is a new temporary pacing lead with a soft tip intended to minimize the risk of perforation and a novel active fixation mechanism designed to enhance lead stability. METHODS: Data from 269 consecutive structural heart procedures were collected. Outcomes included device safety (absence of clinically significant cardiac perforation, new pericardial effusion, or sustained ventricular arrhythmia) and efficacy (clinically acceptable pacing thresholds with successful pace capture throughout the index procedure). Postprocedure practices and sustained lead performance were also analyzed. RESULTS: The Tempo lead was successfully positioned in the right ventricle and achieved pacing in 264 of 269 patients (98.1%). Two patients (0.8%) experienced loss of pace capture. Procedural mean pace capture threshold (PCT) was 0.7 ± 0.8 mA. There were no clinically significant perforations, pericardial effusions, or sustained device-related arrhythmias. The Tempo lead was left in place postprocedure in 189 patients (71.6%) for mean duration of 43.3 ± 0.7 hr (range 2.5-221.3 hr) with final PCT of 0.84 ± 1.04 mA (n = 80). Of these patients, 84.1% mobilized out of bed with no lead dislodgment. CONCLUSION: The Tempo lead is safe and effective for temporary cardiac pacing for structural heart procedures, provides stable peri and postprocedural pacing and allows mobilization of patients who require temporary pacing leads.


Asunto(s)
Estimulación Cardíaca Artificial , Procedimientos Quirúrgicos Cardíacos , Marcapaso Artificial , Atención Perioperativa/instrumentación , Anciano , Anciano de 80 o más Años , Estimulación Cardíaca Artificial/efectos adversos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Diseño de Equipo , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Seguridad del Paciente , Atención Perioperativa/efectos adversos , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos , Función Ventricular Derecha
8.
Catheter Cardiovasc Interv ; 93(4): 740-748, 2019 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-30341970

RESUMEN

OBJECTIVES: To assess the treatment effect of TAVR versus SAVR on clinical outcomes to 3 years in patients stratified by chronic kidney disease (CKD) by retrospectively studying patients randomized to TAVR or SAVR. BACKGROUND: The impact of CKD on mid-term outcomes of patients undergoing TAVR versus SAVR is unclear. METHODS: Patients randomized to TAVR or SAVR in the CoreValve US Pivotal High Risk Trial were retrospectively stratified by eGFR: none/mild or moderate/severe CKD. To evaluate the impact of baseline CKD in TAVR patients only, all patients undergoing an attempted TAVR implant in the US Pivotal Trial and CAS were stratified by baseline eGFR into none/mild, moderate, and severe CKD. The primary endpoint was major adverse cardiovascular and renal events (MACRE), a composite of all-cause mortality, myocardial infarction, stroke/TIA, and new requirement of dialysis. RESULTS: Moderate/severe CKD was present in 62.7% and 60.7% of high-risk patients randomized to TAVR or SAVR, respectively. Baseline characteristics were similar between TAVR and SAVR patients in both CKD subgroups, except for higher rates of diabetes and higher serum creatinine in SAVR patients. Among high-risk patients with moderate/severe CKD, TAVR provided a lower 3-year MACRE rate compared with SAVR: 42.1% vs. 51.0, P = .04. Of 3,733 extreme- and high-risk TAVR patients, 39.9% had none/mild, 53.8% moderate, and 6.4% severe CKD. Worsening baseline CKD was associated with increased 3-year MACRE rates [none/mild 51.5%, moderate 54.5%, severe 63.1%, P = .001]. CONCLUSIONS: TAVR results in lower 3-year MACRE versus SAVR in high-risk patients with moderate/severe CKD. In patients undergoing TAVR, worsening CKD increases mid-term mortality and MACRE. Randomized trials of TAVR vs. SAVR in patients with moderate-severe CKD would help elucidate the best treatment for these complex patients. TRIAL REGISTRATION: CoreValve US Pivotal Trial: NCT01240902. CoreValve Continued Access Study: NCT01531374.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Tasa de Filtración Glomerular , Implantación de Prótesis de Válvulas Cardíacas , Riñón/fisiopatología , Insuficiencia Renal Crónica/fisiopatología , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Ensayos Clínicos Controlados Aleatorios como Asunto , Diálisis Renal , Insuficiencia Renal Crónica/diagnóstico , Insuficiencia Renal Crónica/mortalidad , Insuficiencia Renal Crónica/terapia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Estados Unidos
9.
Pacing Clin Electrophysiol ; 42(7): 980-988, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30969440

RESUMEN

BACKGROUND: Heart block requiring a pacemaker is common after self-expandable transcatheter aortic valve replacement (SE-TAVR); however, conduction abnormalities may improve over time. Optimal device management in these patients is unknown. OBJECTIVE: To evaluate the long-term, natural history of conduction disturbances in patients undergoing pacemaker implantation following SE-TAVR. METHODS: All patients who underwent new cardiac implantable electronic device (CIED) implantation at Michigan Medicine following SE-TAVR placement between January 1, 2012 and September 25, 2017 were identified. Electrocardiogram and device interrogation data were examined during follow-up to identify patients with recovery of conduction. Logistic regression analysis was used to compare clinical and procedural variables to predict conduction recovery. RESULTS: Following SE-TAVR, 17.5% of patients underwent device placement for new atrioventricular (AV) block. Among 40 patients with an average follow-up time of 17.1 ± 8.1 months, 20 (50%) patients had durable recovery of AV conduction. Among 20 patients without long-term recovery, four (20%) had transient recovery. The time to transient conduction recovery was 2.2 ± 0.2 months with repeat loss of conduction at 8.2 ± 0.9 months. On multivariate analysis, larger aortic annular size (odds ratio: 0.53 [0.28-0.86]/mm, P = 0.02) predicted lack of conduction recovery. CONCLUSIONS: Half of the patients undergoing CIED placement for heart block following SE-TAVR recovered AV conduction within several months and maintained this over an extended follow-up period. Some patients demonstrated transient recovery of conduction before recurrence of conduction loss. Larger aortic annulus diameter was negatively associated with conduction recovery.


Asunto(s)
Bloqueo Atrioventricular/fisiopatología , Sistema de Conducción Cardíaco/fisiopatología , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Electrocardiografía , Femenino , Humanos , Masculino
10.
J Theor Biol ; 450: 37-42, 2018 08 07.
Artículo en Inglés | MEDLINE | ID: mdl-29705490

RESUMEN

We introduce a mathematical model that describes the allometry of physical characteristics of hollow organs behaving as pressure vessels based on the physics of ideal pressure vessels. The model was validated by studying parameters such as body and organ mass, systolic and diastolic pressures, internal and external dimensions, pressurization energy and organ energy output measurements of pressure-based organs in a wide range of mammals and birds. Seven rules were derived that govern amongst others, lack of size efficiency on scaling to larger organ sizes, matching organ size in the same species, equal relative efficiency in pressurization energy across species and direct size matching between organ mass and mass of contents. The lung, heart and bladder follow these predicted theoretical relationships with a similar relative efficiency across various mammalian and avian species; an exception is cardiac output in mammals with a mass exceeding 10 kg. This may limit massive body size in mammals, breaking Cope's rule that populations evolve to increase in body size over time. Such a limit was not found in large flightless birds exceeding 100 kg, leading to speculation about unlimited dinosaur size should dinosaurs carry avian-like cardiac characteristics.


Asunto(s)
Estructuras Animales/fisiología , Modelos Teóricos , Presión , Estructuras Animales/anatomía & histología , Animales , Aves/anatomía & histología , Tamaño Corporal , Dinosaurios/anatomía & histología , Modelos Biológicos , Tamaño de los Órganos
11.
Catheter Cardiovasc Interv ; 89(6): 966-973, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28145612

RESUMEN

OBJECTIVES: We sought to evaluate the incidence, risk factors, in-hospital, and long-term outcomes and predictors of mortality of coronary artery perforations (CAP) in the contemporary percutaneous coronary intervention (PCI) era. BACKGROUND: CAP is a rare but serious complication of PCI associated with increased risk of morbidity and mortality. METHODS: We included 181,590 procedures performed across 47 hospitals in Michigan from January 1, 2010 to December 31, 2015. Endpoints evaluated included the incidence of CAP and its association with in-hospital outcomes. Logistic regression analysis was utilized to determine independent risk factors for CAP and to examine whether the effect of CAP on mortality varied by gender. RESULTS: CAP occurred in 625 (0.34%) patients. Independent predictors for CAP included older age, peripheral arterial disease, presence of left ventricular dysfunction or cardiomyopathy, lower body mass index, pre-PCI insertion of a mechanical ventricular support device, treatment of complex lesions (Type C), and treatment of chronic total occlusions, the latter of which was the strongest predictor of perforation (adjusted odds ratio (OR) 7.01, P < 0.001). After adjusting for baseline risk, the incidence of adverse outcomes remained substantially greater in patients with a perforation, with an adjusted OR estimate of 5.00 for mortality (95% CI 3.42-7.31), 3.25 for acute kidney injury (95% CI 2.30-4.58), and 5.26 for transfusion (95% CI 4.03-6.87) (all P < 0.001). Perforation was associated with a higher mortality in women than men (interaction P value = 0.01). CONCLUSIONS: CAP is a rare complication but is associated with high morbidity and mortality especially in women. Further investigation is warranted to determine why women fare worse after CAP. © 2017 Wiley Periodicals, Inc.


Asunto(s)
Vasos Coronarios/lesiones , Lesiones Cardíacas/epidemiología , Intervención Coronaria Percutánea/efectos adversos , Anciano , Anciano de 80 o más Años , Femenino , Lesiones Cardíacas/diagnóstico , Lesiones Cardíacas/mortalidad , Mortalidad Hospitalaria , Humanos , Incidencia , Modelos Logísticos , Masculino , Michigan/epidemiología , Persona de Mediana Edad , Análisis Multivariante , Oportunidad Relativa , Intervención Coronaria Percutánea/mortalidad , Puntaje de Propensión , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores Sexuales , Factores de Tiempo , Resultado del Tratamiento
12.
Catheter Cardiovasc Interv ; 87(3): 376-80, 2016 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-26489781

RESUMEN

OBJECTIVE: To assess the impact of simulation training on complications associated with femoral arterial access obtained by first year cardiology fellows. BACKGROUND: Prior studies demonstrate a higher incidence of arterial access related complications among patients undergoing invasive cardiac procedures. METHODS: First year cardiology fellows at four teaching hospitals in Michigan tracked their femoral access experience and any associated complications between July 2011 and June 2013. Fellows starting their academic training in July 2012 were first trained on a specially developed simulator before starting their rotation in the catheterization laboratory. The primary outcome was access proficiency, defined as five successful femoral access attempts without any complication or need to seek help from a more experienced team member. RESULTS: A total of 1,278 femoral access attempts were made by 21 fellows in 2011-2012 compared with 869 femoral access attempts made by 21 fellows in 2012-2013. There was a lower rate of access related complications in patients undergoing access attempts by first year fellows in year 2 compared with year 1 (2.1% versus 4.5%, P = 0.003). The number of procedures to achieve procedural proficiency was significantly higher in year 1 compared with year 2 (median 20 versus 10, P = 0.007). CONCLUSIONS: Incorporation of simulation in the training of first year fellows was associated with an improvement in proficiency and a clinically meaningful reduction in vascular complications.


Asunto(s)
Cateterismo Periférico/métodos , Educación de Postgrado en Medicina/métodos , Arteria Femoral , Modelos Anatómicos , Modelos Cardiovasculares , Entrenamiento Simulado/métodos , Cateterismo Periférico/efectos adversos , Competencia Clínica , Hospitales de Enseñanza , Humanos , Curva de Aprendizaje , Michigan
13.
Echocardiography ; 31(8): 947-55, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24446589

RESUMEN

BACKGROUND: We have developed new universal strain software (USS) that can be used to perform speckle tracking of any Digital Imaging and Communications in Medicine (DICOM) image, regardless of the ultrasound system used to obtain it. METHODS: Fifty patients prospectively underwent echocardiography immediately prior to cardiac catheterization. Biplane peak global longitudinal strain (GLS), peak systolic longitudinal strain rate (SSR), peak early diastolic longitudinal strain rate (DSR), and peak early diastolic circumferential strain rate (DCSR) were determined using conventional strain software (CSS) that uses raw data, and using the new USS applied to DICOM images. RESULTS: Universal strain software correlated with CSS for GLS (r = 0.78, P < 0.001), SSR (r = 0.78, P < 0.001), DSR (r = 0.54, P < 0.001), and DCSR (r = 0.43, P = 0.019). GLS and SSR using USS correlated with left ventricular ejection fraction (LVEF) (r = -0.67 and -0.71, respectively) as well as using CSS (r = -0.66 and -0.71). Patients with diastolic dysfunction had significantly lower DSR (0.61 vs. 0.87/sec, P = 0.02) and DCSR (0.89 vs. 1.23/sec, P = 0.03), and less negative GLS (-10.8 vs. -16.1%, P = 0.002) using USS in all patients, as well as among those with LVEF ≥ 50%. Receiver-operating characteristic (ROC) analysis for detection of diastolic dysfunction revealed a sensitivity and specificity of 82% and 83% for DCSR < 1.09/sec (area under the curve [AUC = 0.80]) and 85% and 83% for GLS > -13.7% (AUC = 0.84) using USS. CONCLUSION: Universal strain software can be used to accurately assess LV systolic and diastolic function using speckle tracking echocardiography.


Asunto(s)
Algoritmos , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Interpretación de Imagen Asistida por Computador/métodos , Programas Informáticos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología , Diástole , Módulo de Elasticidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Validación de Programas de Computación , Estrés Mecánico , Volumen Sistólico , Sístole , Ultrasonografía
14.
Artículo en Inglés | MEDLINE | ID: mdl-38871537

RESUMEN

BACKGROUND: Permanent pacemaker implantation (PPI) rates following transcatheter aortic valve replacement (TAVR) remain a concern. We assessed the PPI rates over time in patients implanted with an Evolut supra-annular, self-expanding transcatheter valve from the US STS/ACC TVT Registry. METHODS: Patients who underwent TAVR with an Evolut R, Evolut PRO or Evolut PRO+ valve between July 2018 (Q3) and June 2021 (Q2) were included. PPI rates were reported by calendar quarter. In-hospital PPI rates were reported as proportions and 30-day rates as Kaplan-Meier estimates. A Cox regression model was used to determine potential predictors of a new PPI within 30 days of the TAVR procedure. RESULTS: From July 2018 to June 2021, 54,014 TAVR procedures were performed using Evolut valves. Mean age was 79.3 ± 8.8 years and 49.2 % were male. The 30-day PPI rate was 16.6 % in 2018 (Q3) and 10.8 % in 2021 (Q2, 34.9 % decrease, p < 0.001 for trend across all quarters). The in-hospital PPI rate decreased by 40.1 %; from 14.7 % in 2018 (Q3) to 8.8 % in 2021 (Q2) (p < 0.001 for trend across all quarters). Significant predictors of a new PPI within 30 days included a baseline conduction defect, history of atrial fibrillation, home oxygen, and diabetes mellitus. CONCLUSION: From 2018 to 2021, TAVR with an Evolut transcatheter heart valve in over 50,000 patients showed a significant decreasing trend in the rates of in-hospital and 30-day PPI, representing the lowest rate of PPI in any large real-world registry of Evolut. During the same evaluated period, high device success and shorter length of stay was also observed.

15.
Cardiovasc Revasc Med ; 58: 60-67, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37550123

RESUMEN

BACKGROUND: Patients with high bleeding risk (HBR) are often treated with abbreviated dual antiplatelet therapy (DAPT) after percutaneous coronary intervention (PCI) to reduce bleeding risk, however this strategy is associated with an increase in ischemic events, especially if the acute PCI result is suboptimal. We compared clinical outcomes among patients with HBR treated with 1-month DAPT who underwent intravascular ultrasound (IVUS)- or optical coherence tomography (OCT)-guided PCI versus those who underwent angiography-guided PCI without intravascular imaging. METHODS: The Onyx ONE Clear study includes patients with HBR from the Onyx ONE US/Japan and Onyx ONE randomized studies who were treated with the Resolute Onyx zotarolimus-eluting stent. The primary endpoint was the composite of cardiac death (CD) or myocardial infarction (MI) between 1 month and 2 years after PCI. Propensity-score adjustments and matching were performed for differences in baseline and procedural characteristics between groups. RESULTS: Among the 1507 patients in Onyx ONE Clear, 271 (18.0 %) had IVUS or OCT used during PCI (Imaging-guided group) and 1236 (82.0 %) underwent Angiography-guided PCI (Angio-guided group). Imaging-guided patients were less likely to present with atrial fibrillation, acute coronary syndrome, and left ventricle ejection fraction ≤35 %. Conversely, Imaging-guided patients were more likely to have complex (ACC/AHA type B2/C), longer, and heavily calcified lesions. Between 1 month and 2 years, the composite rate of CD or MI was similar between Imaging-guided and Angio-guided patients (9.9 % vs. 12.4 %, P = 0.33). There was also no difference between groups after adjustment; (P = 0.56). However, CD was significantly lower among Imaging-guided patients (2.7 % vs. 6.1 %, P = 0.048). There were no between-group differences in MI or stent thrombosis. Propensity score matching results were similar. CONCLUSION: Despite higher lesion complexity, using intravascular imaging guidance for PCI between 1-month and 2-years follow-up had comparable outcomes with angiographic guidance alone in patients with HBR treated with 1-month DAPT. (ClinicalTrials.gov: Identifier: NCT03647475 and NCT03344653). NON-STANDARD ABBREVIATIONS AND ACRONYMS: BARC: Bleeding Academic Research Consortium; DAPT: dual antiplatelet therapy; DES: drug-eluting stent; HBR: high bleeding risk; IVUS: intravascular ultrasound; OCT: optical coherence tomography; SAPT: single antiplatelet therapy.


Asunto(s)
Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Angiografía Coronaria/efectos adversos , Angiografía Coronaria/métodos , Stents Liberadores de Fármacos/efectos adversos , Infarto del Miocardio/terapia , Infarto del Miocardio/tratamiento farmacológico , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Inhibidores de Agregación Plaquetaria/efectos adversos , Resultado del Tratamiento , Estudios Prospectivos
16.
JACC Cardiovasc Interv ; 17(14): 1667-1675, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39048253

RESUMEN

BACKGROUND: Outcomes from transcatheter aortic valve replacement (TAVR) in low-surgical risk patients with bicuspid aortic stenosis beyond 2 years are limited. OBJECTIVES: This study aimed to evaluate 3-year clinical and echocardiographic outcomes from the Evolut Low Risk Bicuspid Study. METHODS: The Evolut Low Risk Bicuspid Study is a prospective, multicenter, single-arm study conducted in 25 U.S. CENTERS: Patients with severe aortic stenosis at low surgical risk with bicuspid aortic valve anatomy (all subtypes) underwent TAVR with a self-expanding, supra-annular Evolut R or PRO (Medtronic) bioprosthesis. An independent clinical events committee adjudicated all deaths and endpoint-related adverse events, and a central echocardiographic core laboratory assessed hemodynamic endpoints. RESULTS: An attempted implant was performed in 150 patients from December 2018 to October 2019. The mean age was 70.3 ± 5.5 years, 48% (72/150) of the patients were women, and the mean Society of Thoracic Surgeons Predicted Risk of Mortality score was 1.3% (Q1-Q3: 0.9%-1.7%). Sievers type 1 was the dominant bicuspid morphology (90.7%, 136/150). The Kaplan-Meier rates of all-cause mortality or disabling stroke were 1.3% (95% CI: 0.3%-5.3%) at 1 year, 3.4% (95% CI: 1.4%-8.1%) at 2 years, and 4.1% (95% CI: 1.6%-10.7%) at 3 years. The incidence of new permanent pacemaker implantation was 19.4% (95% CI: 12.4%-29.6%) at 3 years. There were no instances of moderate or severe paravalvular aortic regurgitation at 2 and 3 years after TAVR. CONCLUSIONS: The 3-year results from the Evolut Low Risk Bicuspid Study demonstrate low rates of all-cause mortality or disabling stroke and favorable hemodynamic performance.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Bioprótesis , Prótesis Valvulares Cardíacas , Hemodinámica , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Masculino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Factores de Riesgo , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/anomalías , Medición de Riesgo , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/fisiopatología , Estados Unidos/epidemiología , Índice de Severidad de la Enfermedad , Complicaciones Posoperatorias/mortalidad , Recuperación de la Función , Anciano de 80 o más Años , Persona de Mediana Edad , Enfermedades de las Válvulas Cardíacas/fisiopatología , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/mortalidad
17.
Am J Cardiol ; 214: 1-7, 2024 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-38110018

RESUMEN

Transcatheter aortic valve replacement (TAVR) provides an option for extreme-risk patients who underwent reoperation for a failed surgical aortic bioprosthesis. Long-term data on patients who underwent TAVR within a failed surgical aortic valve (TAV-in-SAV) are limited. The CoreValve Expanded Use Study evaluated patients at extreme surgical risk who underwent TAV-in-SAV. Outcomes at 5 years were analyzed by SAV failure mode (stenosis, regurgitation, or combined). Echocardiographic outcomes are site-reported. TAV-in-SAV was attempted in 226 patients with a mean age of 76.7 ± 10.8 years; 63.3% were male, the Society of Thoracic Surgeons predicted risk of mortality score was 9.0 ± 6.7%, and 87.5% had a New York Heart Association classification III or IV symptoms. Most of the failed surgical bioprostheses were stented (81.9%), with an average implant duration of 10.2 ± 4.3 years. The 5-year all-cause mortality or major stroke rate was 47.2% in all patients; 54.4% in the stenosis, 37.6% in the regurgitation, and 38.0% in the combined groups (p = 0.046). At 5 years, all-cause mortality was higher in patients with versus without 30-day severe prosthesis-patient mismatch (51.7% vs 38.3%, p = 0.026). The overall aortic valve reintervention rate was 5.9%; highest in the regurgitation group (12.6%). The mean aortic valve gradient was 14.1 ± 9.8 mm Hg and effective orifice area was 1.57 ± 0.70 at 5 years. Few patients had >mild paravalvular regurgitation at 5 years (5.5% moderate, 0.0% severe). TAV-in-SAV with supra-annular, self-expanding TAVR continues to represent a safe and lasting intermediate option for extreme-risk patients who have appropriate sizing of the preexisting failed surgical valve. Clinical and hemodynamic outcomes were stable through 5 years.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Anciano , Anciano de 80 o más Años , Femenino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estudios de Seguimiento , Constricción Patológica/etiología , Constricción Patológica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Instrumentos Quirúrgicos , Diseño de Prótesis , Factores de Riesgo
18.
JACC Cardiovasc Interv ; 17(8): 1007-1016, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38573257

RESUMEN

BACKGROUND: Data on valve reintervention after transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) are limited. OBJECTIVES: The authors compared the 5-year incidence of valve reintervention after self-expanding CoreValve/Evolut TAVR vs SAVR. METHODS: Pooled data from CoreValve and Evolut R/PRO (Medtronic) randomized trials and single-arm studies encompassed 5,925 TAVR (4,478 CoreValve and 1,447 Evolut R/PRO) and 1,832 SAVR patients. Reinterventions were categorized by indication, timing, and treatment. The cumulative incidence of reintervention was compared between TAVR vs SAVR, Evolut vs CoreValve, and Evolut vs SAVR. RESULTS: There were 99 reinterventions (80 TAVR and 19 SAVR). The cumulative incidence of reintervention through 5 years was higher with TAVR vs SAVR (2.2% vs 1.5%; P = 0.017), with differences observed early (≤1 year; adjusted subdistribution HR: 3.50; 95% CI: 1.53-8.02) but not from >1 to 5 years (adjusted subdistribution HR: 1.05; 95% CI: 0.48-2.28). The most common reason for reintervention was paravalvular regurgitation after TAVR and endocarditis after SAVR. Evolut had a significantly lower incidence of reintervention than CoreValve (0.9% vs 1.6%; P = 0.006) at 5 years with differences observed early (adjusted subdistribution HR: 0.30; 95% CI: 0.12-0.73) but not from >1 to 5 years (adjusted subdistribution HR: 0.61; 95% CI: 0.21-1.74). The 5-year incidence of reintervention was similar for Evolut vs SAVR (0.9% vs 1.5%; P = 0.41). CONCLUSIONS: A low incidence of reintervention was observed for CoreValve/Evolut R/PRO and SAVR through 5 years. Reintervention occurred most often at ≤1 year for TAVR and >1 year for SAVR. Most early reinterventions were with the first-generation CoreValve and managed percutaneously. Reinterventions were more common following CoreValve TAVR compared with Evolut TAVR or SAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Complicaciones Posoperatorias , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Complicaciones Posoperatorias/cirugía , Diseño de Prótesis , Ensayos Clínicos Controlados Aleatorios como Asunto , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento , Incidencia , Retratamiento
19.
JACC Cardiovasc Interv ; 17(8): 979-988, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38658126

RESUMEN

BACKGROUND: Symptomatic patients with severe aortic stenosis (AS) at high risk for surgical aortic valve replacement (SAVR) sustain comparable improvements in health status over 5 years after transcatheter aortic valve replacement (TAVR) or SAVR. Whether a similar long-term benefit is observed among intermediate-risk AS patients is unknown. OBJECTIVES: The purpose of this study was to assess health status outcomes through 5 years in intermediate risk patients treated with a self-expanding TAVR prosthesis or SAVR using data from the SURTAVI (Surgical Replacement and Transcatheter Aortic Valve Implantation) trial. METHODS: Intermediate-risk patients randomized to transfemoral TAVR or SAVR in the SURTAVI trial had disease-specific health status assessed at baseline, 30 days, and annually to 5 years using the Kansas City Cardiomyopathy Questionnaire (KCCQ). Health status was compared between groups using fixed effects repeated measures modelling. RESULTS: Of the 1,584 patients (TAVR, n = 805; SAVR, n = 779) included in the analysis, health status improved more rapidly after TAVR compared with SAVR. However, by 1 year, both groups experienced large health status benefits (mean change in KCCQ-Overall Summary Score (KCCQ-OS) from baseline: TAVR: 20.5 ± 22.4; SAVR: 20.5 ± 22.2). This benefit was sustained, albeit modestly attenuated, at 5 years (mean change in KCCQ-OS from baseline: TAVR: 15.4 ± 25.1; SAVR: 14.3 ± 24.2). There were no significant differences in health status between the cohorts at 1 year or beyond. Similar findings were observed in the KCCQ subscales, although a substantial attenuation of benefit was noted in the physical limitation subscale over time in both groups. CONCLUSIONS: In intermediate-risk AS patients, both transfemoral TAVR and SAVR resulted in comparable and durable health status benefits to 5 years. Further research is necessary to elucidate the mechanisms for the small decline in health status noted at 5 years compared with 1 year in both groups. (Safety and Efficacy Study of the Medtronic CoreValve® System in the Treatment of Severe, Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement [SURTAVI]; NCT01586910).


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Arteria Femoral , Estado de Salud , Prótesis Valvulares Cardíacas , Calidad de Vida , Recuperación de la Función , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Masculino , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento , Anciano , Anciano de 80 o más Años , Factores de Riesgo , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Medición de Riesgo , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Periférico/efectos adversos , Punciones , Diseño de Prótesis
20.
Artículo en Inglés | MEDLINE | ID: mdl-38599918

RESUMEN

BACKGROUND: The next generation supra-annular, self-expanding Evolut FX transcatheter aortic valve (TAV) system was designed to improve catheter deliverability, provide stable and symmetric valve deployment, and assess commissural alignment during the procedure. The impact of these modifications has not been clinically evaluated. METHODS: Procedural information was collected by survey in 2 Stages: Stage I comprised 23 centers with extensive experience with Evolut TAV systems, and Stage II comprised an additional 46 centers with a broad range of balloon- and self-expanding system experience. Operators were to compare the experience with the Evolut FX to the predicate Evolut PRO+ system. RESULTS: There were 285 cases during Stage I from June 24 to August 12, 2022, and 254 cases during Stage II from August 15 to September 11, 2022. Overall, the cusp overlap technique was used in 88.6 %, and commissural alignment was achieved in 96.1 % of these cases. Compared to implanter's previous experience with the Evolut PRO+ system, less resistance was noted with the Evolut FX system: in 83.0 % of cases during vascular insertion, in 84.7 % of cases while tracking through the vasculature, in 84.4 % of cases while traversing over the arch, and 76.1 % of cases in advancing across the valve. Better symmetry of valve depth was observed in 423 of 525 cases (80.6 %). CONCLUSION: Evolut FX system design modifications translated into improvements in catheter deliverability, deployment symmetry and stability, and commissural alignment as assessed by experienced self-expanding and balloon expandable operators.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA