Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 213
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
N Engl J Med ; 385(18): 1643-1655, 2021 10 28.
Artículo en Inglés | MEDLINE | ID: mdl-34449185

RESUMEN

BACKGROUND: The appropriate duration of dual antiplatelet therapy in patients at high risk for bleeding after the implantation of a drug-eluting coronary stent remains unclear. METHODS: One month after they had undergone implantation of a biodegradable-polymer sirolimus-eluting coronary stent, we randomly assigned patients at high bleeding risk to discontinue dual antiplatelet therapy immediately (abbreviated therapy) or to continue it for at least 2 additional months (standard therapy). The three ranked primary outcomes were net adverse clinical events (a composite of death from any cause, myocardial infarction, stroke, or major bleeding), major adverse cardiac or cerebral events (a composite of death from any cause, myocardial infarction, or stroke), and major or clinically relevant nonmajor bleeding; cumulative incidences were assessed at 335 days. The first two outcomes were assessed for noninferiority in the per-protocol population, and the third outcome for superiority in the intention-to-treat population. RESULTS: Among the 4434 patients in the per-protocol population, net adverse clinical events occurred in 165 patients (7.5%) in the abbreviated-therapy group and in 172 (7.7%) in the standard-therapy group (difference, -0.23 percentage points; 95% confidence interval [CI], -1.80 to 1.33; P<0.001 for noninferiority). A total of 133 patients (6.1%) in the abbreviated-therapy group and 132 patients (5.9%) in the standard-therapy group had a major adverse cardiac or cerebral event (difference, 0.11 percentage points; 95% CI, -1.29 to 1.51; P = 0.001 for noninferiority). Among the 4579 patients in the intention-to-treat population, major or clinically relevant nonmajor bleeding occurred in 148 patients (6.5%) in the abbreviated-therapy group and in 211 (9.4%) in the standard-therapy group (difference, -2.82 percentage points; 95% CI, -4.40 to -1.24; P<0.001 for superiority). CONCLUSIONS: One month of dual antiplatelet therapy was noninferior to the continuation of therapy for at least 2 additional months with regard to the occurrence of net adverse clinical events and major adverse cardiac or cerebral events; abbreviated therapy also resulted in a lower incidence of major or clinically relevant nonmajor bleeding. (Funded by Terumo; MASTER DAPT ClinicalTrials.gov number, NCT03023020.).


Asunto(s)
Síndrome Coronario Agudo/terapia , Hemorragia/inducido químicamente , Intervención Coronaria Percutánea , Inhibidores de Agregación Plaquetaria/administración & dosificación , Síndrome Coronario Agudo/complicaciones , Síndrome Coronario Agudo/mortalidad , Anciano , Enfermedades Cardiovasculares/mortalidad , Quimioterapia Combinada , Stents Liberadores de Fármacos , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Infarto del Miocardio/etiología , Inhibidores de Agregación Plaquetaria/efectos adversos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Factores de Riesgo , Accidente Cerebrovascular/etiología , Trombosis/prevención & control
2.
Am Heart J ; 261: 35-44, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36931370

RESUMEN

BACKGROUND: Large-scale registries can provide valuable complementary data to randomized controlled trials (RCT) for the postmarketing evaluation of coronary stents, but their scientific relevance remains debated. METHODS: We sought to compare the evidence on the performance of a single coronary stent platform generated by the RCT for its regulatory approval and a well-conducted international registry. Patients treated with the Ultimaster coronary stent in the CENTURY II (CII-UM) trial (n = 551) were compared to patients in the real-world e-ULTIMASTER (e-UM) registry (n = 35,389). All major events were adjudicated by an independent clinical event committee in both studies. Propensity weighted analysis was used to balance baseline and procedural differences between the 2 populations. RESULTS: Coronary artery disease was more complex in e-UM compared to CII-UM, including more acute coronary syndromes, multivessel disease, left main, arterial, or venous grafts, and chronic total occlusions (P < .005 for all). At one-year follow-up and after excluding periprocedural myocardial infarction (MI) there was no statistically significant difference between CII-UM and e-UM regarding all-cause death (hazard ratio [HR] 0.55, 95% confidence interval [CI] 0.26-1.20, P = .14), cardiac death (HR 0.71, 95% CI 0.29-1.72, P = .45), target lesion failure (HR 1.18, 95% CI 0.78-1.78, P = .44), and target vessel MI (HR 0.76, 95% CI 0.24-2.38, P = .63). However, target vessel revascularization rate was significantly higher in CII-UM than in e-UM, HR 1.78, 95% CI 1.23-2.56, P = .002. CONCLUSIONS: A well-conducted large-scale registry can provide valuable complementary evidence to RCTs on the postmarket performance of new coronary stents, across a wider range of uses and various geographic areas.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Resultado del Tratamiento , Stents Liberadores de Fármacos/efectos adversos , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/complicaciones , Infarto del Miocardio/etiología , Stents/efectos adversos , Sistema de Registros , Intervención Coronaria Percutánea/efectos adversos , Factores de Riesgo , Ensayos Clínicos Controlados Aleatorios como Asunto
3.
Catheter Cardiovasc Interv ; 102(3): 430-439, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37464969

RESUMEN

BACKGROUND: Percutaneous coronary intervention (PCI) for bifurcation lesions can be technically challenging and is associated with higher risk. There is little data on sex-based differences in strategy and outcomes in bifurcation PCI. AIMS: We sought to assess whether differences exist between women and men in the treatment and outcomes of bifurcation PCI. METHODS: We collected data on 4006 patients undergoing bifurcation PCI, from the e-ULTIMASTER study, a prospective, multicentre study enrolling patients from 2014 to 2018. We divided the bifurcation cohort according to sex, with 1-year follow-up of outcomes (target lesion failure [TLF], target vessel failure [TVF], and patient-oriented composite endpoint [POCE]). FINDINGS: Women were older (69.2 ± 10.9 years vs. 64.4 ± 11.0 years), with a greater burden of cardiovascular comorbidities. For true and non-true bifurcation lesions, women and men were equally likely to undergo a single stent approach (true: 63.2% vs. 63.6%, p = 0.79, non-true: 95.4% vs. 94.3%, p = 0.32), with similar rates of final kissing balloon (FKB) (37.2% vs. 35.5%, p = 0.36) and proximal optimization (POT) (34.4% vs. 34.2%, p = 0.93) in cases where two stents were used. Lastly, after propensity score matching, there was no difference between women and men in the incidence of the composite endpoints of TLF (5.5% vs. 5.2%, RR 1.05 [95% CI 0.77-1.44], p = 0.75), TVF (6.2% vs. 6.3%, RR 0.99 [95% CI 0.74-1.32], p = 0.96), and POCE (9.9% vs. 9.5%, RR 1.05 [95% CI 0.83-1.31], p = 0.70). CONCLUSION: In this contemporary, real-world study of bifurcation PCI, we report no difference in stent strategy between women and men, with similar outcomes at 1-year.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Masculino , Humanos , Femenino , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Resultado del Tratamiento , Stents , Sistema de Registros , Angiografía Coronaria
4.
Circulation ; 144(15): 1196-1211, 2021 10 12.
Artículo en Inglés | MEDLINE | ID: mdl-34455849

RESUMEN

BACKGROUND: The optimal duration of antiplatelet therapy (APT) in patients at high bleeding risk with or without oral anticoagulation (OAC) after coronary stenting remains unclear. METHODS: In the investigator-initiated, randomize, open-label MASTER DAPT trial (Management of High Bleeding Risk Patients Post Bioresorbable Polymer Coated Stent Implantation With an Abbreviated Versus Standard DAPT Regimen), 4579 patients at high bleeding risk were randomized after 1-month dual APT to abbreviated or nonabbreviated APT strategies. Randomization was stratified by concomitant OAC indication. In this subgroup analysis, we report outcomes of populations with or without an OAC indication. In the population with an OAC indication, patients changed immediately to single APT for 5 months (abbreviated regimen) or continued ≥2 months of dual APT and single APT thereafter (nonabbreviated regimen). Patients without an OAC indication changed to single APT for 11 months (abbreviated regimen) or continued ≥5 months of dual APT and single APT thereafter (nonabbreviated regimen). Coprimary outcomes at 335 days after randomization were net adverse clinical outcomes (composite of all-cause death, myocardial infarction, stroke, and Bleeding Academic Research Consortium 3 or 5 bleeding events); major adverse cardiac and cerebral events (all-cause death, myocardial infarction, and stroke); and type 2, 3, or 5 Bleeding Academic Research Consortium bleeding. RESULTS: Net adverse clinical outcomes or major adverse cardiac and cerebral events did not differ with abbreviated versus nonabbreviated APT regimens in patients with OAC indication (n=1666; hazard ratio [HR], 0.83 [95% CI, 0.60-1.15]; and HR, 0.88 [95% CI, 0.60-1.30], respectively) or without OAC indication (n=2913; HR, 1.01 [95% CI, 0.77-1.33]; or HR, 1.06 [95% CI, 0.79-1.44]; Pinteraction=0.35 and 0.45, respectively). Bleeding Academic Research Consortium 2, 3, or 5 bleeding did not significantly differ in patients with OAC indication (HR, 0.83 [95% CI, 0.62-1.12]) but was lower with abbreviated APT in patients without OAC indication (HR, 0.55 [95% CI, 0.41-0.74]; Pinteraction=0.057). The difference in bleeding in patients without OAC indication was driven mainly by a reduction in Bleeding Academic Research Consortium 2 bleedings (HR, 0.48 [95% CI, 0.33-0.69]; Pinteraction=0.021). CONCLUSIONS: Rates of net adverse clinical outcomes and major adverse cardiac and cerebral events did not differ with abbreviated APT in patients with high bleeding risk with or without an OAC indication and resulted in lower bleeding rates in patients without an OAC indication. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03023020.


Asunto(s)
Anticoagulantes/uso terapéutico , Hemorragia/tratamiento farmacológico , Inhibidores de Agregación Plaquetaria/uso terapéutico , Stents/normas , Administración Oral , Anciano , Anticoagulantes/farmacología , Femenino , Humanos , Masculino , Inhibidores de Agregación Plaquetaria/farmacología , Factores de Riesgo
5.
Catheter Cardiovasc Interv ; 100(2): 179-187, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35621281

RESUMEN

INTRODUCTION: Long drug-eluting stents may limit the issue of overlapping multiple stents when treating long coronary lesions. AIM: The aim of the study was to assess the safety and efficacy of the 48 mm Xience Xpedition everolimus-eluting stent (48mm-EES) for the treatment of long coronary lesions, in an all-comer population. METHODS: Patients receiving at least one 48mm-EES were prospectively included from March 2014 to December 2018. The primary endpoint was target lesion failure (TLF), defined as a composite of cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularization (TLR) at 1 year. The main secondary endpoint was the patient-oriented composite endpoint (POCE) defined as a composite of death, stroke, myocardial infarction, and reintervention. RESULTS: A total of 268 patients with 276 long coronary lesions, including 94 chronic total occlusions (CTO), were successfully treated using at least one 48mm-EES. The total stent length per lesion was 66 ± 22 mm. A single 48mm-EES was suitable to successfully treat the target lesion in 48% of cases (60% for non-CTO lesions). One-year follow-up rate was 96.3%. TLF occurred in 13 patients (5.3%), mainly driven by TLR (4.1%). Two cardiac death occurred (0.7%). POCE occurred in 30 patients (11.6%) mainly driven by repeat revascularization (9.7%). Definite stent thrombosis was observed in two patients (0.7%). No difference was observed in one-year outcomes between single 48mm-EES and multiple stents implantation as well as between CTO and non-CTO lesions. CONCLUSION: The 48mm-EES is safe and effective to treat long coronary lesions, including CTOs, and provides attractive cost-effectiveness by limiting multiple stenting.


Asunto(s)
Fármacos Cardiovasculares , Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Fármacos Cardiovasculares/efectos adversos , Muerte , Everolimus/efectos adversos , Humanos , Estimación de Kaplan-Meier , Intervención Coronaria Percutánea/efectos adversos , Diseño de Prótesis , Factores de Riesgo , Sirolimus , Factores de Tiempo , Resultado del Tratamiento
6.
Catheter Cardiovasc Interv ; 99(4): 1047-1058, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35170843

RESUMEN

OBJECTIVE: We investigated the effect of proximal optimization technique (POT) on coronary bifurcation stent failure (BSF) in cross-over stenting by comparing with the kissing balloon technique (KBT) in a multicenter randomized PROPOT trial. BACKGROUND: POT is recommended due to increased certainty for optimal stent expansion and side branch (SB) wiring. METHODS: We randomized 120 patients treated with crossover stenting into the POT group, which was followed by SB dilation (SBD), and the KBT group. Finally, 52 and 57 patients were analyzed by optical coherence tomography before SBD and at the final procedure, respectively. Composite BSF was defined as a maximal malapposition distance of >400 µm, or malapposed and SB-jailed strut rates of >5.95% and >21.4%, respectively. RESULTS: Composite BSF before SBD in the POT and KBT groups was observed in 29% and 26% of patients, respectively. In the POT group, differences in stent volumetric index between the proximal and distal bifurcation (odds ratio [OR] 60.35, 95% confidential interval [CI] 0.13-0.93, p = 0.036) and between the proximal bifurcation and bifurcation core (OR: 3.68, 95% CI: 1.01-13.40, p = 0.048) were identified as independent risk factors. Composite BSF at final in 27% and 32%, and unplanned additional procedures in 38% and 25% were observed, respectively. Composite BSF before SBD was a risk factor for the former (OR: 6.33, 95% CI: 1.10-36.50, p = 0.039) and the latter (OR: 6.43, 95% CI: 1.25-33.10, p = 0.026) in the POT group. CONCLUSION: POT did not result in a favorable trend in BSF. Insufficient expansion of the bifurcation core after POT was associated with BSF.


Asunto(s)
Angioplastia Coronaria con Balón , Enfermedad de la Arteria Coronaria , Insuficiencia Cardíaca , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/métodos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/etiología , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Insuficiencia Cardíaca/etiología , Humanos , Stents , Tomografía de Coherencia Óptica , Resultado del Tratamiento
7.
Eur Heart J ; 42(23): 2265-2269, 2021 06 14.
Artículo en Inglés | MEDLINE | ID: mdl-33822924

RESUMEN

Transcatheter aortic valve implantation (TAVI) is effective in older patients with symptomatic severe aortic stenosis, while the indication has recently broadened to younger patients at lower risk. Although thromboembolic and bleeding complications after TAVI have decreased over time, such adverse events are still common. The recommendations of the latest 2017 ESC/EACTS Guidelines for the management of valvular heart disease on antithrombotic therapy in patients undergoing TAVI are mostly based on expert opinion. Based on recent studies and randomized controlled trials, this viewpoint document provides updated therapeutic insights in antithrombotic treatment during and after TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Trombosis , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/tratamiento farmacológico , Estenosis de la Válvula Aórtica/cirugía , Consenso , Fibrinolíticos/uso terapéutico , Humanos , Trombosis/tratamiento farmacológico , Trombosis/etiología , Trombosis/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
8.
Catheter Cardiovasc Interv ; 98(3): 511-519, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33211387

RESUMEN

OBJECTIVES: The aim of this study was to determine the 3-year outcomes of patients treated with Absorb bioresorbable vascular scaffold (BVS) implantation. BACKGROUND: Randomized trials and observational registries performed in patients undergoing percutaneous coronary intervention have demonstrated higher 1-year and midterm rates of device thrombosis and adverse events with BVS compared to contemporary drug eluting stent. Data on long-term follow-up of patients treated with BVS are scarce. METHODS: All patients treated with BVS were included in a large nationwide prospective multicenter registry (FRANCE ABSORB). The primary endpoint was a composite of cardiovascular death, myocardial infarction, and target lesion revascularization at 3 years. Secondary endpoints were 3-year scaffold thrombosis and target vessel revascularization (TVR). RESULTS: Between September 2014 and April 2016, 2070 patients were included (mean age 55 ± 11 years; 80% men). The indication was acute coronary syndrome (ACS) in 49% of patients. At 3 years, the primary endpoint occurred in 184 patients (8.9%) and 3-year mortality in 43 patients (2.1%). Scaffold thrombosis and TVR rates through 3 years were, respectively, 3 and 7.6%. In a multivariable analysis, independent predictors of primary endpoint occurrence were diabetes, oral anticoagulation, active smoking, absence of initial angiographic success and the association of a total BVS length ≥30 mm with the use of 2.5 mm diameter BVS. CONCLUSIONS: Although 3-year mortality was low in this ACS population, device-related events were significant beyond 1 year. Total BVS length and 2.5 mm BVS were associated with higher rates of MACE at long-term follow-up.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Implantes Absorbibles , Adulto , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Everolimus , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Resultado del Tratamiento
9.
Catheter Cardiovasc Interv ; 98(6): 1102-1110, 2021 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-33269506

RESUMEN

OBJECTIVES: This study explores the safety and efficacy of thin strut MeRes100 sirolimus-eluting bioresorbable vascular scaffold (BRS) in patients with de novo coronary artery lesions. BACKGROUND: In interventional cardiology, the emergence of BRS technology is catalyzing the next paradigm shift. METHODS: The MeRes-1 Extend was a multicenter, prospective, single-arm, open-label study enrolling 64 patients in Spain, Macedonia, Brazil, South Africa, Malaysia, and Indonesia. The safety endpoint was major adverse cardiac events (MACE) which composed of cardiac death, myocardial infarction (MI), and ischemia-driven target lesion revascularization (ID-TLR). The imaging efficacy endpoint was mean in-scaffold late lumen loss (LLL) evaluated by quantitative coronary angiography (QCA). Optical coherence tomography (OCT) imaging was performed at baseline and 6-month follow-up. RESULTS: A total of 69 target lesions were identified in 64 enrolled patients (mean age 58.30 ± 9.02 years). Of the treated lesions, 49 (71.01%) lesions were of type B2/C. Procedural and device success was achieved in 64 and 62 patients, respectively. At 2-year follow-up, MACE was reported in one patient (1.61%) in the form of ID-TLR. There was no case of MI, cardiac death or scaffold thrombosis through 2-year. In a subset of 32 patients, paired QCA showed mean in-scaffold LLL of 0.18 ± 0.31 mm at 6-month follow-up. In a subset of 21 patients, OCT revealed 97.95 ± 3.69% strut coverage with mean scaffold area of 7.56 ± 1.79 mm2 and no evidence of strut malapposition. CONCLUSIONS: The clinical and imaging outcomes of MeRes-1 Extend trial demonstrated favorable safety and efficacy of MeRes100 sirolimus-eluting BRS in patients with de novo coronary artery lesions.


Asunto(s)
Fármacos Cardiovasculares , Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Implantes Absorbibles , Anciano , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Sirolimus/efectos adversos , Resultado del Tratamiento
10.
Catheter Cardiovasc Interv ; 95(2): 175-184, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31033154

RESUMEN

OBJECTIVES: To assess the long-term safety and efficacy of a sirolimus-eluting stent with bioresorbable polymer (BP-SES; Ultimaster), in comparison to a benchmark everolimus-eluting, permanent polymer stent (PP-EES; Xience), in a prespecified subgroup of patients with multivessel coronary artery disease (MVD) enrolled in the CENTURY II trial. BACKGROUND: The use of coronary stenting in high-risk subgroups, like MVD patients, is rising. The clinical evidence, including long-term comparative analysis of the efficacy and safety benefits of different new-generation drug eluting stents, however, remains insufficient. METHODS: Among 1,119 patients (intention-to-treat) enrolled in the CENTURY II prospective, randomized, single-blind, multicenter trial, a prespecified subgroup of 456 MVD patients were allocated by stratified randomization to treatment with BP-SES (n = 225) or PP-EES (n = 231). The previously reported primary endpoint of this study was freedom from target lesion failure (TLF: a composite of cardiac death, target vessel-related myocardial infarction [MI] and clinically-indicated target lesion revascularization) at 9 months. RESULTS: In this MVD substudy, baseline patient, lesion and procedure characteristics were similar between the treatment arms. At 1 and 5 years, both BP-SES and PP-EES displayed low and comparable rates of TLF (5.3 vs. 7.8%; p = .29 and 10.2 vs. 13.4%; p = .29), and definite or probable stent thrombosis (0.4 vs. 1.3%; p = .33 and 0.9 vs. 1.7%; p = .43), respectively. Composite endpoint of cardiac death and MI, and patient-oriented composite endpoint of any death, MI, and coronary revascularizations were also similar. CONCLUSIONS: These results confirm good long-term safety and efficacy of the studied bioresorbable polymer stent in this high-risk patient population.


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Estenosis Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Polímeros/química , Sirolimus/administración & dosificación , Anciano , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/fisiopatología , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/mortalidad , Estenosis Coronaria/fisiopatología , Europa (Continente) , Everolimus/efectos adversos , Femenino , Humanos , Japón , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Estudios Prospectivos , Diseño de Prótesis , República de Corea , Factores de Riesgo , Método Simple Ciego , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
11.
Circulation ; 137(5): 464-479, 2018 01 30.
Artículo en Inglés | MEDLINE | ID: mdl-29089314

RESUMEN

BACKGROUND: The Absorb bioresorbable vascular scaffold (BVS) completely resorbs within 3 years after coronary artery implantation. The safety and effectiveness of BVS through this critical 3-year period have not been characterized. METHODS: We performed an individual-patient-data pooled meta-analysis of the 4 randomized ABSORB trials in which 3389 patients with coronary artery disease were randomly assigned to everolimus-eluting Absorb BVS (n=2164) or cobalt-chromium everolimus-eluting stents (n=1225). The primary efficacy outcome measure was target lesion failure (cardiac mortality, target vessel myocardial infarction, or ischemia-driven target lesion revascularization), and the primary safety outcome measure was device thrombosis. RESULTS: BVS compared with cobalt-chromium everolimus-eluting stents resulted in higher 3-year rates of target lesion failure (11.7% versus 8.1%; risk ratio [RR], 1.38; 95% confidence interval [CI], 1.10-1.73; P=0.006), driven by greater target vessel myocardial infarction (7.8% versus 4.2%; RR, 1.72; 95% CI, 1.26-2.35; P=0.0006) and ischemia-driven target lesion revascularization (6.6% versus 4.4%; RR, 1.44; 95% CI, 1.05-1.98; P=0.02), with comparable cardiac mortality (1.1% versus 1.1%; RR, 0.93; 95% CI, 0.47-1.88; P=0.85). Device thrombosis rates through 3 years were also higher with BVS (2.4% versus 0.6%; RR, 3.71; 95% CI, 1.70-8.11; P=0.001). Between 1 and 3 years, target lesion failure rates (6.1% versus 3.9%; P=0.02) and device thrombosis rates (1.1% versus 0.0%; P<0.0001) were higher with BVS than cobalt-chromium everolimus-eluting stents. CONCLUSIONS: In the present individual-patient-data pooled meta-analysis of the ABSORB trials, BVS was associated with increased rates of target lesion failure and device thrombosis between 1 and 3 years and cumulatively through 3 years of follow-up compared with everolimus-eluting stents. CLINICAL TRIAL REGISTRATION: URL: https://clinicaltrials.gov. Unique identifiers: NCT01751906, NCT01844284, NCT01923740, and NCT01425281.


Asunto(s)
Implantes Absorbibles , Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos , Infarto del Miocardio/cirugía , Intervención Coronaria Percutánea/instrumentación , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/epidemiología , Humanos , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/mortalidad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Diseño de Prótesis , Ensayos Clínicos Controlados Aleatorios como Asunto , Recurrencia , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
12.
Am Heart J ; 209: 97-105, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30703644

RESUMEN

BACKGROUND: The optimal duration of antiplatelet therapy in high-bleeding risk (HBR) patients with coronary artery disease treated with newer-generation drug-eluting bioresorbable polymer-coated stents remains unclear. DESIGN: MASTER DAPT (clinicaltrial.govNCT03023020) is an investigator-initiated, open-label, multicenter, randomized controlled trial comparing an abbreviated versus a standard duration of antiplatelet therapy after bioresorbable polymer-coated Ultimaster (TANSEI) sirolimus-eluting stent implantation in approximately 4,300 HBR patients recruited from ≥100 interventional cardiology centers globally. After a mandatory 30-day dual-antiplatelet therapy (DAPT) run-in phase, patients are randomized to (a) a single antiplatelet regimen until study completion or up to 5 months in patients with clinically indicated oral anticoagulation (experimental 1-month DAPT group) or (b) continue DAPT for at least 5 months in patients without or 2 in patients with concomitant indication to oral anticoagulation, followed by a single antiplatelet regimen (standard antiplatelet regimen). With a final sample size of 4,300 patients, this study is powered to assess the noninferiority of the abbreviated antiplatelet regimen with respect to the net adverse clinical and major adverse cardiac and cerebral events composite end points and if satisfied for the superiority of abbreviated as compared to standard antiplatelet therapy duration in terms of major or clinically relevant nonmajor bleeding. Study end points will be adjudicated by a blinded Clinical Events Committee. CONCLUSIONS: The MASTER DAPT study is the first randomized controlled trial aiming at ascertaining the optimal duration of antiplatelet therapy in HBR patients treated with sirolimus-eluting bioresorbable polymer-coated stent implantation.


Asunto(s)
Implantes Absorbibles/efectos adversos , Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos/efectos adversos , Terapia Antiplaquetaria Doble/métodos , Intervención Coronaria Percutánea/efectos adversos , Polímeros , Hemorragia Posoperatoria/terapia , Anciano de 80 o más Años , Femenino , Humanos , Inmunosupresores/farmacología , Masculino , Intervención Coronaria Percutánea/métodos , Hemorragia Posoperatoria/etiología , Sirolimus/farmacología
13.
Catheter Cardiovasc Interv ; 93(7): 1367-1373, 2019 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-30536569

RESUMEN

OBJECTIVE: This study sought to assess the potential benefits of the transradial approach (TRA) as an alternative vascular access to the classical contralateral femoral approach for transcatheter aortic valve replacement (TAVR). BACKGROUND: Vascular and bleeding complications in TAVR have gradually decreased owing to operator experience and downsizing of the delivery system. However, about 1/4 of vascular access site complications are related to the transfemoral (TF) secondary access. METHODS: We compared the outcomes at 30 days according to VARC-2 after TAVR of a prospective cohort of 217 consecutive patients undergoing right or left TRA as the second vascular access (TRA-TF TAVR) and a retrospective cohort of 194 consecutive patients undergoing TF approach as a second vascular access (TF-TF TAVR). RESULTS: Baseline clinical characteristics and risk scores were well matched in both groups. Procedural success rate was 99.7%. Fluoro time was significantly lower in the TF-TF TAVR group (16.9 ± 7.2 vs. 19.1 ± 7.8 min, P = 0.003); however, there was no significant difference in x-ray exposure, procedure time or amount of contrast used. In the TRA-TF TAVR group, there were no complications related to the TRA access and there were less vascular and bleeding complications (18.0% vs. 9.7%, P = 0.014; 17.0% vs. 9.2%, P = 0.026, respectively), although blood transfusion requirement or hospitalization duration stay were similar in both groups. CONCLUSIONS: TRA approach as alternative secondary vascular access in TAVR is safe and feasible and is associated with a significant decrease in vascular and bleeding complications. Further, large-scale studies are warranted to confirm the potential benefit of this approach.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Cateterismo Periférico , Arteria Femoral , Hospitales de Alto Volumen , Arteria Radial , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Cateterismo Periférico/efectos adversos , Femenino , Arteria Femoral/diagnóstico por imagen , Humanos , Tiempo de Internación , Masculino , Tempo Operativo , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/terapia , Estudios Prospectivos , Punciones , Arteria Radial/diagnóstico por imagen , Exposición a la Radiación , Radiografía Intervencional , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
14.
Inorg Chem ; 58(22): 15255-15268, 2019 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-31674174

RESUMEN

The investigation of layered intermetallic compounds containing light elements like hydrogen has great potential for superconductivity. We studied the insertion of carbon atoms in CeScSi-type intermetallics (an ordered variant of the La2Sb structure type), and here, we report the new carbide NdScSiC0.5. Carbon insertion keeps the pristine compound's space group, I4/mmm, but causes an anisotropic expansion of the unit cell with an increase in the a parameter and a decrease of the c parameter. X-ray and neutron diffraction measurements indicate the existence of a NdScSiCx solid solution (0.2 < x ≤ 0.5) with carbon atoms occupying only the Sc4Nd2 octahedral sites while leaving the Nd4 tetrahedral sites vacant. Magnetization measurements unveil a linear reduction of the ferromagnetic ordering temperature from TC = ∼171 K to ∼50 K with increasing carbon content. The ferromagnetic structures of the pristine NdScSi and the filled NdScSiC0.5 have been determined from neutron diffraction measurements. Finally, we discuss the effect of carbon versus hydrogen insertion on electronic and magnetic properties based on density functional theory calculations. Although the unpaired spin density channels between Nd and Sc atoms (responsible of the high Curie temperature in NdScSi) are reduced upon carbon insertion, the strong Nd-C interaction, linked to a reduced c lattice parameter in NdScSiC0.5, ensures a strong magnetic coupling between the Nd double layer along the c axis and the ferromagnetic order is preserved.

15.
Eur Heart J ; 39(36): 3381-3389, 2018 09 21.
Artículo en Inglés | MEDLINE | ID: mdl-30124834

RESUMEN

Aim: In current device trials, the values of angiographic late lumen loss (LLL) have become extremely low and the relationship between LLL and clinical endpoints has not been recently re-evaluated. The impact of LLL on target lesion revascularization (TLR) in a patient- and study-level analysis of contemporary coronary devices was investigated. Methods and results: We performed a patient-level meta-analysis of seven randomized controlled trials including 2426 patients treated with first- and second-generation drug-eluting stents (DES) and a study-level meta-analysis of 40 studies including 19 199 patients treated with CE-marked DES. In the patient-level analysis, the probability regression curve showed an exponential relationship between in-stent LLL and 2-year incidence of TLR. The optimal cut-off value of LLL based on Youden's index for 2-year TLR event was 0.50 mm. In the Cox proportional hazard model, LLL >0.50 mm was independently associated with an increased incidence of TLR up to 4 years after angiographic follow-up {adjusted hazard ratio (HR) 6.62 [95% confidence interval (95% CI) 4.67-9.39], P < 0.001}. In the meta-regression analysis of the DES studies, pooled mean value of LLL was as low as 0.23 mm (95% CI 0.20-0.26), and there was a moderate correlation between the 1- and 5-year incidence of TLR and the percentage of the lesions with LLL >0.50 mm (R2 = 0.44, P < 0.001 at 1 year, R2 = 0.40, P < 0.001 at 5 years). Conclusion: An angiographic LLL ≤0.50 mm was not predictive of the incidence of TLR whereas a LLL >0.50 mm was. Low LLL in contemporary device trials may not be a sufficiently discriminating parameter for the comparative evaluation of devices.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Revascularización Miocárdica/métodos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/patología , Humanos
16.
Catheter Cardiovasc Interv ; 91(5): 997-999, 2018 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-27142180

RESUMEN

The expandable sheath was designed with a lower profile in order to reduce the incidence of vascular complications of transcatheter aortic valve implantation using transfemoral approach. However, once the prosthesis has crossed the sheath, it could be difficult to retrieve it from the body. This is the first case of successful bail-out in an instance of delivery balloon shaft malfunction subsequent to the crossing of an expandable sheath during implantation of an Edwards SAPIEN 3 prosthesis. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Valvuloplastia con Balón/efectos adversos , Valvuloplastia con Balón/instrumentación , Catéteres Cardíacos , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Falla de Equipo , Humanos , Masculino , Diseño de Prótesis , Radiografía Intervencional , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
17.
Inorg Chem ; 57(22): 14230-14239, 2018 Nov 19.
Artículo en Inglés | MEDLINE | ID: mdl-30407001

RESUMEN

Intermetallic phases have been investigated with respect to their ability to accept small atoms in interstitial sites without changing the host structure. Among those, the intermetallic compounds crystallizing in the tetragonal CeScSi-type structure are able to absorb hydrogen atoms. These compounds are of particular interest because they can show electride-like character and, therefore, can be exploited as new catalysts. Here we report the case of GdScGe which uptakes hydrogen at 623 K and under a H2 gas pressure between 0.5 and 4 MPa. The formation of the hydride GdScGeH, with H atoms entering into the [Gd4] tetrahedra, preserves the host structure but induces an anisotropic volume expansion with a strong increase of the c-parameter and a slight decrease of the a-parameter. Interestingly, we show for the first time for this family of materials that hydrogen insertion reduces the dimensionality of the magnetic and transport properties from 3D to quasi-2D which results in a vanishing of the ferromagnetic order ( TC = 350 K for GdScGe) and a change of the metallic conduction behavior to a nonmetallic one. As evidenced by density functional theory calculations, such drastic effects are accounted for through the Gd-H chemical bonding effect and the oxidizing effect of H whereas the volume expansion plays only a minor role.

18.
Lancet ; 388(10059): 2479-2491, 2016 11 19.
Artículo en Inglés | MEDLINE | ID: mdl-27806897

RESUMEN

BACKGROUND: No medium-term data are available on the random comparison between everolimus-eluting bioresorbable vascular scaffolds and everolimus-eluting metallic stents. The study aims to demonstrate two mechanistic properties of the bioresorbable scaffold: increase in luminal dimensions as a result of recovered vasomotion of the scaffolded vessel. METHODS: The ABSORB II trial is a prospective, randomised, active-controlled, single-blind, parallel two-group, multicentre clinical trial. We enrolled eligible patients aged 18-85 years with evidence of myocardial ischaemia and one or two de-novo native lesions in different epicardial vessels. We randomly assigned patients (2:1) to receive treatment with an everolimus-eluting bioresorbable scaffold (Absorb; Abbott Vascular, Santa Clara, CA, USA) or treatment with an everolimus-eluting metallic stent (Xience; Abbott Vascular, Santa Clara, CA, USA). Randomisation was stratified by diabetes status and number of planned target lesions. At 3 year follow-up, the primary endpoint was superiority of the Absorb bioresorbable scaffold versus the Xience metallic stent in angiographic vasomotor reactivity after administration of intracoronary nitrate. The co-primary endpoint is the non-inferiority of angiographic late luminal loss. For the endpoint of vasomotion, the comparison was tested using a two-sided t test. For the endpoint of late luminal loss, non-inferiority was tested using a one-sided asymptotic test, against a non-inferiority margin of 0·14 mm. The trial is registered at ClinicalTrials.gov, number NCT01425281. FINDINGS: Between Nov 28, 2011, and June 4, 2013, we enrolled 501 patients and randomly assigned them to the Absorb group (335 patients, 364 lesions) or the Xience group (166 patients, 182 lesions). The vasomotor reactivity at 3 years was not statistically different (Absorb group 0·047 mm [SD 0·109] vs Xience group 0·056 mm [0·117]; psuperiority=0·49), whereas the late luminal loss was larger in the Absorb group than in the Xience group (0·37 mm [0·45] vs 0·25 mm [0·25]; pnon-inferiority=0·78). This difference in luminal dimension was confirmed by intravascular ultrasound assessment of the minimum lumen area (4·32 mm2 [SD 1·48] vs 5·38 mm2 [1·51]; p<0·0001). The secondary endpoints of patient-oriented composite endpoint, Seattle Angina Questionnaire score, and exercise testing were not statistically different in both groups. However, a device-oriented composite endpoint was significantly different between the Absorb group and the Xience group (10% vs 5%, hazard ratio 2·17 [95% CI 1·01-4·70]; log-rank test p=0·0425), mainly driven by target vessel myocardial infarction (6% vs 1%; p=0·0108), including peri-procedural myocardial infarction (4% vs 1%; p=0·16). INTERPRETATION: The trial did not meet its co-primary endpoints of superior vasomotor reactivity and non-inferior late luminal loss for the Absorb bioresorbable scaffold with respect to the metallic stent, which was found to have significantly lower late luminal loss than the Absorb scaffold. A higher rate of device-oriented composite endpoint due to target vessel myocardial infarction, including peri-procedural myocardial infarction, was observed in the Absorb group. The patient-oriented composite endpoint, anginal status, and exercise testing, were not statistically different between both devices at 3 years. Future studies should investigate the clinical impact of accurate intravascular imaging in sizing the device and in optimising the scaffold implantation. The benefit and need for prolonged dual antiplatelet therapy after bioresorbable scaffold implantation could also become a topic for future clinical research. FUNDING: Abbott Vascular.


Asunto(s)
Implantes Absorbibles , Materiales Biocompatibles/uso terapéutico , Estenosis Coronaria/tratamiento farmacológico , Stents Liberadores de Fármacos/estadística & datos numéricos , Everolimus , Inmunosupresores/uso terapéutico , Stents Metálicos Autoexpandibles/estadística & datos numéricos , Estenosis Coronaria/cirugía , Humanos , Isquemia Miocárdica/tratamiento farmacológico , Isquemia Miocárdica/cirugía , Método Simple Ciego , Resultado del Tratamiento , Ultrasonografía Intervencional
19.
Catheter Cardiovasc Interv ; 90(7): 1192-1197, 2017 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-28295996

RESUMEN

OBJECTIVES: Coronary obstruction (CO) is a rare but serious complication of transcatheter aortic valve implantation (TAVI). There are very limited data regarding CO following TAVI. The aim of this study was to evaluate the incidence and outcomes of CO after TAVI and identify the predictors including the valve type. METHODS: Between October 2006 and March 2015, 1,203 TAVI cases were performed in our institution. Of them, 814 cases whose coronary height was measured using computed tomography for screening were analyzed in this study. RESULTS: The Edwards SAPIEN/SAPIEN XT (S/XT) was used in 427 (52.4%) cases, the CoreValve in 265 (32.6%), and the S3 in 122 (15.0%). CO occurred in 8 (1.0%) cases, 1.6% with S/XT, 0.4% with CoreValve, and 0% with S3. All instances of CO occurred at the left coronary artery. The 30-day mortality was significantly higher in cases of CO (37.5% vs. 5.8%, P = 0.010). The frequency of CO tended to be lower in recipients of the CoreValve (0.4%) and S3 (0%) compared with the S/XT (1.6%) (P = 0.188 for CoreValve vs. S/XT, P = 0.022 for S3 vs. S/XT). CONCLUSIONS: CO has poor outcomes and identification of patients at risk of CO to take preventive measures is crucial. The preliminary data showing that the occurrence of CO is low in patients receiving the S3 despite increased prosthesis height need further confirmation. © 2017 Wiley Periodicals, Inc.


Asunto(s)
Válvula Aórtica/cirugía , Estenosis Coronaria/epidemiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/mortalidad , Bases de Datos Factuales , Femenino , Francia/epidemiología , Prótesis Valvulares Cardíacas , Humanos , Incidencia , Masculino , Datos Preliminares , Diseño de Prótesis , Factores de Riesgo , Factores de Tiempo , Tomografía Computarizada por Rayos X , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
20.
Lancet ; 385(9962): 43-54, 2015 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-25230593

RESUMEN

BACKGROUND: Despite rapid dissemination of an everolimus-eluting bioresorbable scaffold for treatment for coronary artery disease, no data from comparisons with its metallic stent counterpart are available. In a randomised controlled trial we aimed to compare an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent. Here we report secondary clinical and procedural outcomes after 1 year of follow-up. METHODS: In a single-blind, multicentre, randomised trial, we enrolled eligible patients aged 18-85 years with evidence of myocardial ischaemia and one or two de-novo native lesions in different epicardial vessels. We randomly assigned patients in a 2:1 ratio to receive treatment with an everolimus-eluting bioresorbable scaffold (Absorb, Abbott Vascular, Santa Clara, CA, USA) or treatment with an everolimus-eluting metallic stent (Xience, Abbott Vascular, Santa Clara, CA, USA). Randomisation was stratified by diabetes status and number of planned target lesions. The co-primary endpoints of this study are vasomotion (change in mean lumen diameter before and after nitrate administration at 3 years) and difference between minimum lumen diameter (after nitrate administration) after the index procedure and at 3 years. Secondary endpoints were procedural performance assessed by quantitative angiography and intravascular ultrasound; composite clinical endpoints based on death, myocardial infarction, and coronary revascularisation; device and procedural success; and angina status assessed by the Seattle Angina Questionnaire and exercise testing at 6 and 12 months. Cumulative angina rate based on adverse event reporting was analysed post hoc. This trial is registered at ClinicalTrials.gov, number NCT01425281. FINDINGS: Between Nov 28, 2011, and June 4, 2013, we enrolled 501 patients and randomly assigned them to the bioresorbable scaffold group (335 patients, 364 lesions) or the metallic stent group (166 patients, 182 lesions). Dilatation pressure and balloon diameter at the highest pressure during implantation or postdilatation were higher and larger in the metallic stent group, whereas the acute recoil post implantation was similar (0.19 mm for both, p=0.85). Acute lumen gain was lower for the bioresorbable scaffold by quantitative coronary angiography (1.15 mm vs 1.46 mm, p<0.0001) and quantitative intravascular ultrasound (2.85 mm(2)vs 3.60 mm(2), p<0.0001), resulting in a smaller lumen diameter or area post procedure. At 1 year, however, cumulative rates of first new or worsening angina from adverse event reporting were lower (72 patients [22%] in the bioresorbable scaffold group vs 50 [30%] in the metallic stent group, p=0.04), whereas performance during maximum exercise and angina status by SAQ were similar. The 1-year composite device orientated endpoint was similar between the bioresorbable scaffold and metallic stent groups (16 patients [5%] vs five patients [3%], p=0.35). Three patients in the bioresorbable scaffold group had definite or probable scaffold thromboses (one definite acute, one definite sub-acute, and one probable late), compared with no patients in the metallic stent group. There were 17 (5%) major cardiac adverse events in the bioresorbable scaffold group compared with five (3%) events in the metallic stent group, with the most common adverse events being myocardial infarction (15 cases [4%] vs two cases [1%], respectively) and clinically indicated target-lesion revascularisation (four cases [1%] vs three cases [2%], respectively). INTERPRETATION: The everolimus-eluting bioresorbable scaffold showed similar 1-year composite secondary clinical outcomes to the everolimus-eluting metallic stent. FUNDING: Abbott Vascular.


Asunto(s)
Implantes Absorbibles , Stents Liberadores de Fármacos , Inmunosupresores/uso terapéutico , Isquemia Miocárdica/tratamiento farmacológico , Sirolimus/análogos & derivados , Andamios del Tejido , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Materiales Biocompatibles/uso terapéutico , Angiografía Coronaria , Everolimus , Femenino , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/cirugía , Estudios Prospectivos , Calidad de Vida , Método Simple Ciego , Sirolimus/uso terapéutico , Encuestas y Cuestionarios , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA