Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Opt Express ; 19(9): 8085-91, 2011 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-21643058

RESUMEN

The outdoor readability of the most popular portable liquid crystal display (LCDs) viz. fringe field switching has been addressed both in single and dual cell gap transflective devices. The devices use dual orientation, such as, homogeneous alignment in transmissive (T) part and 64° twisted alignment in reflective (R) part. The dark states of the proposed devices are achieved by controlling phase retardation in T part and polarization rotation in R part and the white state is realized by rotating optic axis of liquid crystal and removing phase retardation in T and R parts, respectively. The devices show high light efficiency without requiring any optical compensation films, exhibiting strong potential for portable display applications.


Asunto(s)
Presentación de Datos , Cristales Líquidos/química , Refractometría/instrumentación , Campos Electromagnéticos , Diseño de Equipo , Análisis de Falla de Equipo , Cristales Líquidos/efectos de la radiación
2.
Allergy Asthma Immunol Res ; 6(6): 504-10, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25374749

RESUMEN

PURPOSE: Exhaled nitric oxide (NO) is a useful non-invasive biomarker for asthma diagnosis; however, the literature suggests that exhaled NO levels may be affected by demographic factors. The present analysis investigated determinant factors that present exhaled NO reference levels for Korean elderly adults. METHODS: For reference levels, we analyzed the baseline data of healthy adult participants in the Ansung cohort. The fraction of exhaled NO (FeNO) was measured by NIOX MINO®. The characterization of the subjects was performed through structured questionnaires, spirometry, and methacholine challenge tests. To validate the diagnostic utility of the determined reference levels, asthma patients were recruited from medical institutions for FeNO measurement. RESULTS: A total of 570 healthy subjects were analyzed (mean age, 59.9±12.3; male, 37.0%) for reference levels. FeNO levels significantly correlated with weight, height, body mass index, atopy, or forced expiratory volume in 1 second % predicted by simple linear regression analysis. Multiple linear regression analysis identified gender as an independent determinant for FeNO levels; subsequently, the reference values for FeNO were 18.2±10.6 ppb (5th to 95th percentile, 6.0 to 37.4 ppb) for males and 12.1±6.9 ppb (5th to 95th percentile, 2.5 to 27.0 ppb) for females. The diagnostic utility of FeNO reference levels was validated by receiver operating curve analysis (area under curve, 0.900 for males and 0.885 for females) for diagnosing asthma. The optimal cutoff values for the prediction of asthma were 30.5 ppb for males and 20.5 ppb for females. CONCLUSIONS: The current analysis presented reference ranges and the diagnostic utility of FeNO levels for asthma in Korean elderly adults.

SELECCIÓN DE REFERENCIAS