1.
Sensors (Basel) ; 20(20)2020 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-33076533

RESUMEN

The main objectives of this study are to investigate the spectral responses of a fire-damaged concrete slab using Impact-echo (IE) testing, and to develop a simplified model for interpreting the frequency shift due to heat-induced concrete damage after the fire. For these purposes, a reinforced concrete slab specimen (1000 mm (width) by 5000 mm (length) by 210 mm (thickness)) was fabricated in the laboratory. Heat damage in the concrete slab specimen was induced by exposing the bottom of the specimen to the temperatures corresponding to the standard fire curve described in the ASTM E 119 for 3 h. Impact-echo testing was performed on the bottom surface of the concrete slab specimen before and after inducing the fire damage. It was observed that the spectral responses of the fire-damaged concrete were dominated by several non-propagating waves, which resulted in main peak frequencies around 4500 Hz and 5100 Hz. A discrete layered concrete damage model developed in this study was used to reconstruct the variation of the P-wave velocity with the depth of the fire-damaged concrete. It was demonstrated that the predicted P-wave velocity profile using the simplified model showed a good agreement with the measured values from the five core samples, which measured 100 mm (diameter) by 200 mm (height) cylinders, using ultrasonic pulse velocity (UPV) measurements at eight different depths. In addition, the peak frequencies predicted by the simplified model were consistent with the measured peak frequencies. The experimental results in this study demonstrated that IE testing is effective for evaluating the post-fire damage of reinforced concrete slabs. Particularly, the simplified model in this study can be effective for better interpreting the spectral responses of fire-damaged concrete slabs by IE testing.

2.
Materials (Basel) ; 14(7)2021 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-33916382

RESUMEN

It is very important to understand the residual performance of a structure for repair, retrofit, and reuse of a building after a fire. In this study, an experiment is conducted on the residual performance of real-scale siliceous aggregates-based reinforced concrete (RC) wall-slab connection (WSC) after the fire, using the simple calculation method (SCM) of standards (Eurocode, ACI, and NIST) for comparison and analysis. A description of the WSC specimen and detailed methods for the experiment are introduced. The fire test is conducted according to the fire scenario by dividing it into one-sided and two-sided heating based on the wall. In the post-fire residual performance test, the load-displacement and moment-deflection angle relationship according to the fire time are derived and discussed. In addition, the residual mechanical properties after the fire are derived for the 35 MPa siliceous concrete used in the wall-slab specimen. The load and moment, derived using SCM, are compared with the experimental results. Our results show that the one-sided heating test result is close to that of Eurocode's SCM, and the two-sided heating test result is close to that of ACI (NIST)'s SCM. This study provides a database on the residual strength through a real-scale fire test and standard comparison.

3.
Materials (Basel) ; 12(17)2019 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-31443598

RESUMEN

The main objectives of this study are (1) to investigate the effects of heating and cooling on the static and dynamic residual properties of 35 MPa (5000 psi) concrete used in the design and construction of nuclear reactor auxiliary buildings in Korea; and (2) to establish the correlation between static and dynamic properties of heat-damaged concrete. For these purposes, concrete specimens (100 mm × 200 mm cylinder) were fabricated in a batch plant at a nuclear power plant (NPP) construction site in Korea. To induce thermal damages, the concrete specimens were heated to target temperatures from 100 °C to 1000 °C with intervals of 100 °C, at a heating rate of 5 °C/min and allowed to reach room temperature by natural cooling. The dynamic properties (dynamic elastic modulus and dynamic Poisson's ratio) of concrete were evaluated using elastic wave measurements (P-wave velocity measurements according to ASTM C597/C597M-16 and fundamental longitudinal and transverse resonance tests according to ASTM C215-14) before and after the thermal damages. The static properties (compressive strength, static elastic modulus and static Poisson's ratio) of heat-damaged concrete were measured by the uniaxial compressive testing in accordance with ASTM C39-14 and ASTM C469-14. It was demonstrated that the elastic wave velocities of heat-damaged concrete were proportional to the square root of the reduced dynamic elastic moduli. Furthermore, the relationship between static and dynamic elastic moduli of heat-damaged concrete was established in this study. The results of this study could improve the understanding of the static and dynamic residual mechanical properties of Korea NPP concrete under heating and cooling.