Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur J Vasc Endovasc Surg ; 52(4): 427-436, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27498092

RESUMEN

OBJECTIVE/BACKGROUND: The aim was to investigate the expression of genes associated with carotid plaque instability and their protein products at a local and systemic level. METHODS: Carotid plaques from 24 patients undergoing carotid endarterectomy (CEA) were classified as stable or unstable using clinical, histological, ultrasound, and transcranial Doppler criteria, and compared using whole genome microarray chips. Initial results of differentially expressed genes were validated by quantitative reverse transcriptase polymerase chain reaction in an independent group of 96 patients undergoing CEA. The protein product of genes significantly differentially expressed between patients with stable and unstable plaques were analysed by plaque immunohistochemistry and serum protein quantification by enzyme-linked immunosorbent assay on a further independent cohort. RESULTS: Expression of chemokine (c-c-motif) ligand 19 (CCL19) was significantly upregulated in plaques from patients with clinically unstable disease (p < .001). Cathepsin G expression was upregulated in histologically unstable plaques (p = .04). Serum concentration of CCL19 was significantly higher in patients with clinically unstable plaques (p = .02). Immunohistochemical staining for CCL19 demonstrated positive staining in histologically and clinically unstable plaques (p = .03). CCL19 also co-localised with CD3+ T-cell lymphocytes in the core region, around where CCL19 was expressed. CONCLUSIONS: CCL19 is significantly overexpressed in patients with unstable carotid atherosclerotic plaques and may be a possible novel biomarker for identifying high-risk patients in whom more urgent intervention may be indicated.


Asunto(s)
Enfermedades de las Arterias Carótidas/genética , Quimiocina CCL19/genética , Expresión Génica/genética , Regulación hacia Arriba/genética , Arterias Carótidas/patología , Enfermedades de las Arterias Carótidas/patología , Enfermedades de las Arterias Carótidas/cirugía , Catepsina G/genética , Endarterectomía Carotidea , Marcadores Genéticos/genética , Humanos , Pronóstico , Análisis por Matrices de Proteínas
2.
Br J Surg ; 102(8): 866-72, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25974255

RESUMEN

BACKGROUND: Screening for abdominal aortic aneurysm (AAA) has reduced the rate of AAA rupture. However, cardiovascular disease is still a major cause of death in men with an AAA. The aim of this study was to assess cardiovascular risk in patients with a small AAA. METHODS: Standard PRISMA guidelines were followed. Analysis was performed of studies reporting cardiovascular outcomes in patients with a small AAA (30-54 mm). Weighted metaregression was performed for cardiovascular death in patients with a small AAA, and the prevalence of cardiovascular disease was reviewed. RESULTS: Twenty-one articles were identified describing patients with an AAA, and the prevalence of, and death from, cardiovascular disease. Ten of these reported cardiovascular death rates in patients with a small AAA. Some 2323 patients with a small AAA were identified; 335 cardiovascular deaths occurred, of which 37 were due to AAA rupture. Metaregression demonstrated that the risk of cardiovascular death was 3·0 (95 per cent c.i. 1·7 to 4·3) per cent per year in patients with a small AAA (R(2) = 0·902, P < 0·001). The prevalence of ischaemic heart disease (44·9 per cent), myocardial infarction (26·8 per cent), heart failure (4·4 per cent) and stroke (14·0 per cent) was also high in these patients. CONCLUSION: The risk of cardiovascular death in patients with a small AAA is high and increases by approximately 3 per cent each year after diagnosis. Patients with a small AAA have a high prevalence of cardiovascular disease. Patients a small AAA should be considered for lifestyle modifications and secondary cardiovascular protection.


Asunto(s)
Aneurisma de la Aorta Abdominal/complicaciones , Enfermedades Cardiovasculares/mortalidad , Enfermedades Cardiovasculares/epidemiología , Humanos , Masculino , Tamizaje Masivo , Prevalencia , Factores de Riesgo
3.
Br J Surg ; 102(7): 755-66, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25832031

RESUMEN

BACKGROUND: MicroRNAs are crucial in the regulation of cardiovascular disease and represent potential therapeutic targets to decrease abdominal aortic aneurysm (AAA) expansion. The aim of this study was to identify circulating microRNAs associated with AAA. METHODS: Some 754 microRNAs in whole-blood samples from 15 men with an AAA and ten control subjects were quantified using quantitative reverse transcriptase-PCR. MicroRNAs demonstrating a significant association with AAA were validated in peripheral blood and plasma samples of men in the following groups (40 in each): healthy controls, controls with peripheral arterial disease (PAD), men with a small AAA (30-54 mm), those with a large AAA (over 54 mm), and those following AAA repair. MicroRNA expression was also assessed in aortic tissue. RESULTS: Twenty-nine differentially expressed microRNAs were identified in the discovery study. Validation study revealed that let-7e (fold change (FC) -1·80; P = 0·001), miR-15a (FC -2·24; P < 0·001) and miR-196b (FC -2·26; P < 0·001) were downregulated in peripheral blood from patients with an AAA, and miR-411 was upregulated (FC 5·90; P = 0·001). miR-196b was also downregulated in plasma from the same individuals (FC -3·75; P = 0·029). The same miRNAs were similarly expressed differentially in patients with PAD compared with healthy controls. Validated and predicted microRNA targets identified through miRWalk revealed that these miRNAs were all regulators of AAA-related genes (vascular cell adhesion molecule 1, intercellular cell adhesion molecule 1, DAB2 interacting protein, α1-antitrypsin, C-reactive protein, interleukin 6, osteoprotegerin, methylenetetrahydrofolate reductase, tumour necrosis factor α). CONCLUSION: In this study, circulating levels of let-7e, miR-15a, miR-196b and miR-411 were differentially expressed in men with an AAA compared with healthy controls, but also differentially expressed in men with PAD. Modulation of these miRNAs and their target genes may represent a new therapeutic pathway to affect the progression of AAA and atherosclerosis.


Asunto(s)
Aneurisma de la Aorta Abdominal/genética , Predisposición Genética a la Enfermedad , MicroARNs/genética , Enfermedad Arterial Periférica/genética , Aneurisma de la Aorta Abdominal/metabolismo , Aneurisma de la Aorta Abdominal/patología , Marcadores Genéticos , Humanos , Masculino , MicroARNs/metabolismo , Persona de Mediana Edad , Enfermedad Arterial Periférica/metabolismo , Enfermedad Arterial Periférica/patología , Reacción en Cadena de la Polimerasa , Reproducibilidad de los Resultados
4.
Br J Surg ; 101(6): 637-42, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24687390

RESUMEN

BACKGROUND: The National Vascular Registry Report on Surgical Outcomes (NVSRO) coincided with the update of the National Health Service Standard Contract for Specialized Vascular Services in Adults (NHSSCSVS). The latter promises patients minimum standards for vascular centres. The present study aimed to determine whether current data support the standards proposed in the NHSSCSVS. METHODS: Numbers of abdominal aortic aneurysm (AAA) repairs and carotid endarterectomies (CEAs) performed by hospital Trust and surgeon, and their outcomes were obtained from the NVRSO. These were assessed against NHSSCSVS recommendations that included: more than 60 AAA repairs per year per Trust, over 50 CEAs per year per Trust and at least six vascular surgeons per Trust. RESULTS: Based on NVRSO data, 107 hospital Trusts (92.2 per cent) would fail to meet the minimum standards required to achieve vascular centre status. Outcomes were poorer in these hospitals (overall mortality rate after AAA: 2.7 versus 1.3 per cent; P = 0.007). There were strong associations between number of AAA repairs or CEAs per Trust and better outcomes (AAA repair, P < 0.001; CEA, P = 0.004). These remained significant when analysed by individual surgeon (AAA repair, P < 0.001; CEA, P < 0.001). Trusts undertaking 60 or fewer elective AAA repairs per year had significantly higher elective AAA mortality rates (2.7 versus 1·7 per cent; P = 0.010). Trusts performing a minimum of 50 CEAs per year had significantly lower perioperative mortality/morbidity rates (1.9 versus 3.0 per cent; P = 0.032). Trusts with seven or more surgeons demonstrated lower AAA-related mortality rates (1.7 versus 2.7 per cent; P = 0.018). CONCLUSION: Data from the NVRSO suggest that the majority of hospital Trusts presently fail to meet the standards for vascular centre status. NVRSO data support a standard of more than 60 elective AAA repairs and 50 CEAs per Trust per year. A minimum of seven vascular surgeons per unit was associated with better outcomes. These data support the ongoing remodelling of vascular services in the UK.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Centros Quirúrgicos/normas , Procedimientos Quirúrgicos Vasculares/normas , Aneurisma de la Aorta Abdominal/mortalidad , Endarterectomía Carotidea/mortalidad , Endarterectomía Carotidea/normas , Endarterectomía Carotidea/estadística & datos numéricos , Procedimientos Endovasculares/normas , Procedimientos Endovasculares/estadística & datos numéricos , Tamaño de las Instituciones de Salud/estadística & datos numéricos , Mortalidad Hospitalaria , Humanos , Sistema de Registros , Estudios Retrospectivos , Centros Quirúrgicos/estadística & datos numéricos , Resultado del Tratamiento , Reino Unido , Procedimientos Quirúrgicos Vasculares/mortalidad , Procedimientos Quirúrgicos Vasculares/estadística & datos numéricos
5.
Br J Surg ; 101(11): 1358-72, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25131707

RESUMEN

BACKGROUND: Many studies have investigated the systemic and local expression of biomarkers in patients with abdominal aortic aneurysm (AAA). The natural history of AAA varies between patients, and predictors of the presence and diameter of AAA have not been determined consistently. The aim of this study was to perform a systematic review, meta-analysis and meta-regression of studies comparing biomarkers in patients with and without AAA, with the aim of summarizing the association of identified markers with both AAA presence and size. METHODS AND RESULTS: Literature review identified 106 studies suitable for inclusion. Meta-analysis demonstrated a significant difference between matrix metalloproteinase (MMP) 9, tissue inhibitor of matrix metalloproteinase 1, interleukin (IL) 6, C-reactive protein (CRP), α1-antitrypsin, triglycerides, lipoprotein(a), apolipoprotein A and high-density lipoprotein in patients with and without AAA. Although meta-analysis was not possible for MMP-2 in aortic tissue, tumour necrosis factor α, osteoprotegerin, osteopontin, interferon γ, intercellular cell adhesion molecule 1 and vascular cell adhesion molecule 1, systematic review suggested an increase in these biomarkers in patients with AAA. Meta-regression analysis identified a significant positive linear correlation between aortic diameter and CRP level. CONCLUSION: A wide variety of biomarkers are dysregulated in patients with AAA, but their clinical value is yet to be established. Future research should focus on the most relevant biomarkers of AAA, and how they could be used clinically.


Asunto(s)
Aneurisma de la Aorta Abdominal/diagnóstico , Biomarcadores/metabolismo , Aortitis/diagnóstico , Enzimas/metabolismo , Humanos , Metabolismo de los Lípidos/fisiología , Lípidos/análisis , Proteínas/metabolismo , Análisis de Regresión
6.
Eur J Vasc Endovasc Surg ; 47(1): 13-8, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24239144

RESUMEN

OBJECTIVE: The lower procedural risk associated with endovascular aneurysm repair (EVAR) compared with open aneurysm repair (OAR) is well known. Younger patients are likely to represent a group at low perioperative risk. The long-term durability and late complications following EVAR may have more significance when considering the optimal treatment for young patients with a longer life expectancy. This study examined perioperative and long-term outcomes of young patients undergoing aneurysm repair by either open surgical or endovascular means. METHODS: A retrospective review of a prospectively collated database was performed. Patients undergoing elective aneurysm repair at the age of 65 years or younger between January 2000 and September 2010 were included. All EVAR patients were followed up in a nurse-led clinic. Data regarding long-term outcomes for patients undergoing open repair were gathered from case note review. RESULTS: There were 99 patients who underwent open repair and 59 patients who underwent endovascular repair. Groups were well matched in terms of demographics and co-morbidities. 30-day mortality was 1% after open repair. There were no perioperative deaths after endovascular repair. Overall, 30-day complication rates were 15% after open repair and 12% after EVAR. The nature of complications differed between the two groups with the EVAR group experiencing endoleaks and the OAR group demonstrating more cardiorespiratory complications. Mean follow-up was 75.5 months and there was a 14% reintervention rate after EVAR compared with 7% after OAR. CONCLUSION: Young patients are likely to have a lower procedural risk for EVAR and OAR than described in published figures. Although mortality and complication rates in these two groups were similar, the nature of complications occurring following open surgery were often more significant than those occurring after EVAR. There remains a risk of late reintervention following either form of repair.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Aptitud Física , Adulto , Factores de Edad , Anciano , Aneurisma de la Aorta Abdominal/diagnóstico , Aneurisma de la Aorta Abdominal/mortalidad , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Distribución de Chi-Cuadrado , Procedimientos Quirúrgicos Electivos , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Selección de Paciente , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/cirugía , Reoperación , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Análisis de Supervivencia , Factores de Tiempo , Resultado del Tratamiento
7.
Eur J Vasc Endovasc Surg ; 48(4): 391-9, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25042332

RESUMEN

OBJECTIVE: Type II endoleak is the most common complication after endovascular abdominal aortic aneurysm repair (EVAR); however, its natural history is unclear. The aim of this study was to examine the incidence and outcomes of type II endoleak, at a single institution after EVAR. METHODS: A total of 904 consecutive patients who underwent EVAR between September 1995 and July 2013 at a single centre were entered onto a prospective database. All patients were followed up by duplex ultrasound (DUSS). Patients who developed type II endoleak were compared for preoperative demographics, mortality, and sac expansion. RESULTS: A total of 175(19%) patients developed type II endoleak over a median follow-up of 3.6 years (1.5-5.9 years); 54% of type II endoleaks spontaneously resolved within 6 months (0.25-1.2 years). No difference was found in preoperative demographics or choice of endograft between the two groups. Survival was significantly higher in the group with type II endoleak (94.1% vs. 85.6%; p = .01) and this effect was most pronounced in those with late type II endoleaks (97.7% vs. 85.6% p = .004). No difference was seen in aneurysm-related mortality or rate of type I endoleak between the two groups. Freedom from sac expansion (>5 mm from preoperative diameter) was significantly lower in the group of patients with type II endoleak (82.5% vs. 93.2%, p = .0001); however, at a threshold of >10 mm from preoperative diameter no difference was seen. CONCLUSIONS: Patients with isolated type II endoleak demonstrate equivalent aneurysm-related mortality and an improved survival.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Manejo de la Enfermedad , Embolización Terapéutica/normas , Endofuga/terapia , Procedimientos Endovasculares/efectos adversos , Guías de Práctica Clínica como Asunto , Anciano , Endofuga/diagnóstico , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Retrospectivos , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Ultrasonografía Doppler Dúplex
8.
Eur J Vasc Endovasc Surg ; 47(3): 240-2, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24368205

RESUMEN

BACKGROUND: It is common for authors to introduce a paper by demonstrating the importance of the clinical condition being addressed, usually by quoting data such as mortality and prevalence rates. Abdominal aortic aneurysm (AAA) epidemiology is changing, and therefore such figures for AAA are subject to error. The aim of this study was to analyse the accuracy of AAA prevalence and mortality citations in the contemporaneous literature. METHODS: Two separate literature searches were performed using PubMed to identify studies reporting either aneurysm prevalence or mortality. The first 40 articles or those published over the last 2 years were included in each search to provide a snapshot of current trends. For a prevalence citation to be appropriate, a paper had to cite an original article publishing its own prevalence of AAA or a national report. In addition, the cited prevalence should match that published within the referenced article. These reported statistics were compared with the most recent data on aneurysm-related mortality. RESULTS: The prevalence of AAA was reported to be as low as 1% and as high as 12.7% (mean 5.7%, median 5%). Only 47.5% of studies had referenced original articles, national reports or NICE, and only 32.4% of cited prevalences matched those from the referenced article. In total 5/40 studies were completely accurate. 80% of studies cited aneurysm mortality in the USA, with the majority stating 15,000 deaths per year (range 9,000 to 30,000). Current USA crude AAA mortality is 6,289 (2010). CONCLUSION: References for AAA mortality and prevalence reported in the current literature are often inaccurate. This study highlights the importance of accurately reporting mortality and prevalence data and using up-to-date citations.


Asunto(s)
Aneurisma de la Aorta Abdominal/mortalidad , Factores de Edad , Aneurisma de la Aorta Abdominal/epidemiología , Aneurisma de la Aorta Abdominal/terapia , Humanos , Prevalencia
10.
Anaesthesia ; 69(3): 249-58, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24548355

RESUMEN

Mortality after lower limb amputation is high, with UK 30-day mortality rates of 9-17%. We performed a retrospective analysis of factors affecting early and late outcome after lower limb amputation for peripheral vascular disease or diabetic complications at a UK tertiary referral vascular centre between 2003 and 2010. Three hundred and thirty-nine patients (233 male), of median (IQR [range]) age 73 (62-79 [26-92]) years underwent amputation. Thirty-day mortality was 12.4%. On regression modelling, the risk of 30-day mortality was increased in patients of ASA grade ≥ 4 (OR 4.23, 95% CI 2.07-8.63), p < 0.001 and age between 74 and 79 years (OR 3.8, 95% CI 1.10-13.13), p = 0.04 and older than 79 years (OR 4.08, 95% CI 1.25-13.25), p = 0.02. Peri-operative (30-day) mortality for these groups was 23.2%, 13.7% and 18.8%, respectively. Survival and Cox regression analysis demonstrated that long-term mortality was associated with: age 74-79 years (HR 2.15, 95% CI 1.38-3.35), p = 0.001; age > 79 years (HR 2.78, 95% CI 1.82-4.25), p < 0.001; ASA grade ≥ 4 (HR 2.04, 95% CI 1.51-2.75), p < 0.001; out-of-hours operating (HR 1.51, 95% CI 1.08-2.10), p = 0.02; and chronic kidney disease stage 4-5 (1.57, 95% CI 1.07-2.30), p = 0.02. Anaesthetic technique was associated with long-term mortality on survival analysis (p = 0.04), but not when analysed using regression modelling. Mortality after lower limb amputation relates to patient age, ASA, out-of-hours surgery and renal dysfunction. These data support lower limb amputations' being performed during daytime hours and after modification replace with 'of ' correctable risk factors.


Asunto(s)
Amputación Quirúrgica/mortalidad , Extremidad Inferior/cirugía , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Anestesia , Femenino , Estudios de Seguimiento , Tasa de Filtración Glomerular , Hemoglobinas/metabolismo , Humanos , Complicaciones Intraoperatorias/epidemiología , Complicaciones Intraoperatorias/mortalidad , Estimación de Kaplan-Meier , Fallo Renal Crónico/complicaciones , Fallo Renal Crónico/mortalidad , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/mortalidad , Modelos de Riesgos Proporcionales , Análisis de Regresión , Estudios Retrospectivos , Análisis de Supervivencia
11.
Br J Surg ; 100(7): 863-72, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23475697

RESUMEN

BACKGROUND: Any possible long-term benefit from endovascular (EVAR) versus open surgical repair for abdominal aortic aneurysm (AAA) remains unproven. Long-term data from the Open Versus Endovascular Repair (OVER) trial add to the debate regarding long-term all-cause and aneurysm-related mortality. The aim of this study was to investigate 30-day and long-term mortality, reintervention, rupture and morbidity after EVAR and open repair for AAA in a systematic review. METHODS: Standard PRISMA guidelines were followed. Random-effects Mantel-Haenszel meta-analysis was performed to evaluate mortality and morbidity outcomes. RESULTS: The existing published randomized trials, together with information from Medicare and SwedVasc databases, were included in a meta-analysis. This included 25 078 patients undergoing EVAR and 27 142 undergoing open repair for AAA. Patients who had EVAR had a significantly lower 30-day or in-hospital mortality rate (1·3 per cent versus 4·7 per cent for open repair; odds ratio (OR) 0·36, 95 per cent confidence interval 0·21 to 0·61; P < 0·001). By 2-year follow-up there was no difference in all-cause mortality (14·3 versus 15·2 per cent; OR 0·87, 0·72 to 1·06; P = 0·17), which was maintained after at least 4 years of follow-up (34·7 versus 33·8 per cent; OR 1·11, 0·91 to 1·35; P = 0·30). There was no significant difference in aneurysm-related mortality by 2 years or longer follow-up. A significantly higher proportion of patients undergoing EVAR required reintervention (P = 0·003) and suffered aneurysm rupture (P < 0·001). CONCLUSION: There is no long-term survival benefit for patients who have EVAR compared with open repair for AAA. There are also significantly higher risks of reintervention and aneurysm rupture after EVAR.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Rotura de la Aorta/cirugía , Procedimientos Endovasculares/métodos , Aneurisma de la Aorta Abdominal/mortalidad , Rotura de la Aorta/mortalidad , Procedimientos Endovasculares/mortalidad , Humanos , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/mortalidad , Ensayos Clínicos Controlados Aleatorios como Asunto , Reoperación , Análisis de Supervivencia , Resultado del Tratamiento
12.
Br J Surg ; 100(10): 1262-70, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23939840

RESUMEN

BACKGROUND: The aim was to assess the risk of rupture, and determine the benefits of intervention for the treatment of type II endoleak after endovascular abdominal aortic aneurysm repair (EVAR). METHODS: This systematic review was done according to PRISMA guidelines. Outcome data included incidence, spontaneous resolution, sac expansion, interventions, clinical success, and complications including conversion to open repair, and rupture. RESULTS: Thirty-two non-randomized retrospective studies were included, totalling 21 744 patients who underwent EVAR. There were 1515 type II endoleaks and 393 interventions. Type II endoleak was seen in 10·2 per cent of patients after EVAR; 35·4 per cent resolved spontaneously. Fourteen patients (0·9 per cent) with isolated type II endoleak had ruptured abdominal aortic aneurysm; six of these did not have known aneurysm sac expansion. Of 393 interventions for type II endoleak, 28·5 per cent were unsuccessful. Translumbar embolization had a higher clinical success rate than transarterial embolization (81 versus 62·5 per cent respectively; P = 0·024) and fewer recurrent endoleaks were reported (19 versus 35·8 per cent; P = 0·036). Transarterial embolization also had a higher rate of complications (9·2 per cent versus none; P = 0·043). CONCLUSION: Aortic aneurysm rupture after EVAR secondary to an isolated type II endoleak is rare (less than 1 per cent), but over a third occur in the absence of sac expansion. Translumbar embolization had a higher success rate with a lower risk of complications.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Rotura de la Aorta/etiología , Embolización Terapéutica/métodos , Endofuga/etiología , Procedimientos Endovasculares/efectos adversos , Rotura de la Aorta/prevención & control , Endofuga/prevención & control , Humanos , Estudios Multicéntricos como Asunto , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Retrospectivos , Resultado del Tratamiento
13.
Br J Surg ; 100(10): 1302-11, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23797788

RESUMEN

BACKGROUND: Lifelong surveillance is standard after endovascular repair of abdominal aortic aneurysm (EVAR), but remains costly, heterogeneous and poorly calibrated. This study aimed to develop and validate a scoring system for aortic complications after EVAR, informing rationalized surveillance. METHODS: Patients undergoing EVAR at two centres were studied from 2004 to 2010. Preoperative morphology was quantified using three-dimensional computed tomography according to a validated protocol, by investigators blinded to outcomes. Proportional hazards modelling was used to identify factors predicting aortic complications at the first centre, and thereby derive a risk score. Sidak tests between risk quartiles dichotomized patients to low- or high-risk groups. Aortic complications were reported by Kaplan-Meier analysis and risk groups were compared by log rank test. External validation was by comparison of aortic complications between risk groups at the second centre. RESULTS: Some 761 patients, with a median age of 75 (interquartile range 70-80) years, underwent EVAR. Median follow-up was 36 (range 11-94) months. Physiological variables were not associated with aortic complications. A morphological risk score incorporating maximum aneurysm diameter (P < 0·001) and largest common iliac diameter (measured 10 mm from the internal iliac origin; P = 0·004) allocated 75 per cent of patients to a low-risk group, with excellent discrimination between 5-year rates of aortic complication in low- and high-risk groups at both centres (centre 1: 12 versus 31 per cent, P < 0·001; centre 2: 12 versus 45 per cent, P = 0·002). CONCLUSION: The risk score uses commonly available morphological data to stratify the rate of complications after EVAR. The proposals for rationalized surveillance could provide clinical and economic benefits.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Procedimientos Endovasculares/métodos , Complicaciones Posoperatorias/prevención & control , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/patología , Endofuga/etiología , Endofuga/patología , Humanos , Aneurisma Ilíaco/patología , Imagenología Tridimensional , Estimación de Kaplan-Meier , Cuidados a Largo Plazo/métodos , Estudios Prospectivos , Reoperación , Medición de Riesgo/métodos , Tomografía Computarizada por Rayos X , Anomalía Torsional/etiología , Anomalía Torsional/patología
14.
Eur J Vasc Endovasc Surg ; 46(4): 440-5, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23911735

RESUMEN

OBJECTIVE: Endovascular aneurysm sealing (EVAS) using the Nellix system is a promising alternative to endovascular repair (EVR) and open surgery for abdominal aortic aneurysms (AAA). The aim of this study was to investigate the proportion of patients with AAA who are morphologically suitable for treatment with Nellix. METHODS: Patients presenting with AAA were investigated at two regionalised vascular units. Separate cohorts were identified, who had undergone infrarenal EVR, open aneurysm repair, fenestrated endovascular repair (FEVR) or non-operative management. Pre-operative morphology was quantified using three-dimensional computed tomography according to a validated protocol. Each aneurysm was assessed for compliance with the instructions for use (IFU) of Nellix RESULTS: 776 patients were identified with mean age 75 ± 9 years. 730/776 (94.1%) had undergone infrarenal EVR, 6/776 (0.8%) open repair, 27/776 (3.5%) FEVR and 13/776 (1.7%) had been managed non-operatively. 544/776 (70.1%) of all AAA were morphologically suitable for Nellix. 533/730 (73.0%) of patients who had undergone infrarenal EVR were compliant with Nellix IFU, compared with 497/730 (68.1%), 379/730 (51.9%) and 214/730 (29.3%) with the IFU for Medtronic Endurant (p = .04) or Cook Zenith (p < .01) and Gore C3 Excluder (p < .01) endografts respectively. CONCLUSIONS: Nellix technology appears widely applicable to contemporary infrarenal AAA practice, and may provide an option for patients that are outside current EVR device instructions for use. However, formal outcomes study is still required, and will ultimately dictate the clinical relevance of this feasibility study. The major limitation to anatomic suitability for Nellix is currently the maximum patent lumen diameter of large AAA.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Inglaterra , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Diseño de Prótesis , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
15.
Eur J Vasc Endovasc Surg ; 45(2): 128-34, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23273900

RESUMEN

OBJECTIVES: Currently most abdominal aortic aneurysm screening programmes discharge patients with aortic diameter of less than 30 mm. However, sub-aneurysmal aortic dilatation (25 mm-29 mm) does not represent a normal aortic diameter. This observational study aimed to determine the outcomes of patients with screening detected sub aneurysmal aortic dilatation. DESIGN AND METHODS: Individual patient data was obtained from 8 screening programmes that had performed long term follow up of patients with sub aneurysmal aortic dilatation. Outcome measures recorded were the progression to true aneurysmal dilatation (aortic diameter 30 mm or greater), progression to size threshold for surgical intervention (55 mm) and aneurysm rupture. RESULTS: Aortic measurements for 1696 men and women (median age 66 years at initial scan) with sub-aneurysmal aortae were obtained, median period of follow up was 4.0 years (range 0.1-19.0 years). Following Kaplan Meier and life table analysis 67.7% of patients with 5 complete years of surveillance reached an aortic diameter of 30 mm or greater however 0.9% had an aortic diameter of 54 mm. A total of 26.2% of patients with 10 complete years of follow up had an AAA of greater that 54 mm. CONCLUSION: Patients with sub-aneurysmal aortic dilatation are likely to progress and develop an AAA, although few will rupture or require surgical intervention.


Asunto(s)
Aorta Abdominal/patología , Aneurisma de la Aorta Abdominal/diagnóstico , Tamizaje Masivo , Anciano , Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/complicaciones , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/patología , Aneurisma de la Aorta Abdominal/cirugía , Rotura de la Aorta/etiología , Rotura de la Aorta/patología , Dilatación Patológica , Progresión de la Enfermedad , Europa (Continente) , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Tamizaje Masivo/métodos , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Estudios Retrospectivos , Factores de Tiempo , Ultrasonografía , Procedimientos Quirúrgicos Vasculares
16.
Eur J Vasc Endovasc Surg ; 44(6): 556-61, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23122183

RESUMEN

OBJECTIVES: This study aims to evaluate outcomes following EVAR in patients with hostile neck anatomy (HNA). METHODS: Data prospectively collected from 552 elective EVARs were analysed retrospectively. Data regarding neck morphology was obtained from aneurysm stent plans produced prior to EVAR. HNA was defined as any of; neck diameter >28 mm, neck angulation >60°, neck length <15 mm, neck thrombus, or neck flare. RESULTS: 552 patients underwent EVAR. Mean age 73.9 years, mean follow-up 4.1 years. 199 patients had HNA, 353 had favourable neck anatomy (FNA). There was a significant increase in late type I endoleaks (FNA 4.5%, HNA 9.5%; P = 0.02) and total reinterventions (FNA 11.0%, HNA 22.8%; P < 0.01), and a significant decrease in late type II endoleaks in patients with HNA (FNA 16.7%, HNA 10.6%; P < 0.05). There was no significant difference in technical success (FNA 0.6%, HNA 2.0%; p = 0.12), 30-day re-intervention (FNA 2.8%, HNA 5.0%; P = 0.12), 30-day mortality (FNA 1.1%, HNA 0.5%; P = 0.45), 30-day type I endoleaks (FNA 0.8%, HNA 2.5%; P = 0.12), 5-year mortality (FNA 15.1%, HNA 14.6%; P = 0.86), aneurysm-related mortality (FNA 1.7% versus HNA 2.0%; P = 0.79), stent-graft migration (FNA 2.5%, HNA 3.0%; P = 0.75), sac expansion (FNA 13.0%, HNA 9.5%; P = 0.22), or graft rupture (FNA 1.1%, HNA 3.5%; P = 0.05). Binary logistic regression of individual features of HNA revealed secondary intervention (P = 0.009), technical failure (P = 0.02), and late type I endoleaks (P = 0.002), were significantly increased with increased neck diameter. CONCLUSIONS: HNA AAAs can be successfully treated with EVAR. However, surveillance is necessary to detect and treat late type I endoleaks in HNA patients.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Aortografía/métodos , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Distribución de Chi-Cuadrado , Endofuga/etiología , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/mortalidad , Femenino , Migración de Cuerpo Extraño/etiología , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Selección de Paciente , Valor Predictivo de las Pruebas , Modelos de Riesgos Proporcionales , Diseño de Prótesis , Falla de Prótesis , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Stents , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
17.
Eur J Vasc Endovasc Surg ; 44(6): 549-54, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22981409

RESUMEN

OBJECTIVES: To develop and validate an "in house" risk model for predicting perioperative mortality following elective AAA repair and to compare this with other models. DESIGN: Multivariate logistics regression analysis was used to identify risk factors for perioperative-day mortality from one tertiary institution's prospectively maintained database. MATERIALS AND METHODS: Consecutive elective open (564) and endovascular (589) AAA repairs (2000-2010) were split randomly into development (810) and validation (343) data sets. The resultant model was compared to Glasgow Aneurysm Score (GAS), Modified Customised Probability Index (m-CPI), CPI, the Vascular Governance North West (VGNW) model and the Medicare model. RESULTS: Variables associated with perioperative mortality included: increasing age (P = 0.034), myocardial infarct within last 10 years (P = 0.0008), raised serum creatinine (P = 0.005) and open surgery (P = 0.0001). The areas under the receiver operating characteristic curve (AUC) for predicted probability of 30-day mortality in development and validation data sets were 0.79 and 0.82 respectively. AUCs for GAS, m-CPI and CPI were poor (0.63, 0.58 and 0.58 respectively), whilst VGNW and Medicare model were fair (0.73 and 0.79 respectively). CONCLUSIONS: In this study, an "in-house" developed and validated risk model has the most accurate discriminative value in predicting perioperative mortality after elective AAA repair. For purposes of comparative audit with case mix adjustments, national models such as the VGNW or Medicare models should be used.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/mortalidad , Procedimientos Endovasculares/mortalidad , Anciano , Aneurisma de la Aorta Abdominal/mortalidad , Implantación de Prótesis Vascular/efectos adversos , Distribución de Chi-Cuadrado , Procedimientos Quirúrgicos Electivos , Procedimientos Endovasculares/efectos adversos , Inglaterra , Femenino , Mortalidad Hospitalaria , Humanos , Modelos Logísticos , Masculino , Análisis Multivariante , Oportunidad Relativa , Curva ROC , Reproducibilidad de los Resultados , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
18.
Eur J Vasc Endovasc Surg ; 44(2): 127-32, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22658609

RESUMEN

OBJECTIVES: A recent GWAS demonstrated an association between low density lipoprotein receptor related protein 1 (LRP1) and abdominal aortic aneurysm (AAA). This review aims to identify how LRP1 may be involved in the pathogenesis of abdominal aortic aneurysm. DESIGN AND MATERIALS: A systematic review of the English language literature was undertaken in order to determine whether LRP1 and associated pathways were plausible candidates for contributing to the development and/or progression of AAA. METHODS AND RESULTS: A comprehensive literature search of MEDLINE (since 1948), Embase (since 1980) and Health and Psychological Instruments (since 1985) was conducted in January 2012 identified 50 relevant articles. These studies demonstrate that LRP1 has a diverse range of biological functions and is a plausible candidate for playing a central role in aneurysmogenesis. Importantly, LRP1 downregulates MMP (matrix metalloproteinase) activity in vascular smooth muscle cells and regulates other key pathways involved in extracellular matrix remodelling and vascular smooth muscle migration and proliferation. Crucially animal studies have shown that LRP1 depletion leads to progressive destruction of the vascular architecture and aneurysm formation. CONCLUSIONS: Published evidence suggests that LRP1 may play a key role in the development of AAA.


Asunto(s)
Aorta Abdominal/metabolismo , Aneurisma de la Aorta Abdominal/metabolismo , Proteína 1 Relacionada con Receptor de Lipoproteína de Baja Densidad/metabolismo , Animales , Aorta Abdominal/patología , Aneurisma de la Aorta Abdominal/genética , Aneurisma de la Aorta Abdominal/patología , Progresión de la Enfermedad , Predisposición Genética a la Enfermedad , Humanos , Proteína 1 Relacionada con Receptor de Lipoproteína de Baja Densidad/química , Proteína 1 Relacionada con Receptor de Lipoproteína de Baja Densidad/genética , Fenotipo , Polimorfismo de Nucleótido Simple , Conformación Proteica
19.
Eur J Vasc Endovasc Surg ; 44(1): 52-4, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22595147

RESUMEN

INTRODUCTION: Biomarkers have the potential to improve the clinical management of patients with AAA. REPORT: A prospective, proteomics discovery study was undertaken to compare patients with AAA (n = 20) to matched screened controls (n = 19) for plasma protein expression. Surface-Enhanced-Laser-Desorption-Ionization Time of Flight Mass Spectrometry (SELDI ToF MS) coupled with Artificial Neural Networks (ANN) analysis identified six protein related diagnostic biomarker ions with a combined AUC of 0.89. DISCUSSION: This study discovered a signature plasma protein profile for patients with AAA and demonstrated that mass spectrometric based research for disease specific biomarker of AAA is feasible.


Asunto(s)
Aneurisma de la Aorta Abdominal/sangre , Biomarcadores/sangre , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Progresión de la Enfermedad , Humanos , Masculino , Estudios Prospectivos , Proteómica/métodos , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Ultrasonografía
20.
CVIR Endovasc ; 5(1): 29, 2022 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-35748962

RESUMEN

Sirolimus-coated balloons (SCB) have demonstrated much promise as an alternative drug eluting device to the existing paclitaxel coated balloon platforms for the treatment of peripheral arterial disease (PAD). They have been well tested pre-clinically and have demonstrated anti-restenotic effects as well as clinical safety in its use for treatment of coronary artery disease. The existing approved SCBs have thus far demonstrated good short-term patency (12-months) and did not exhibit any major adverse events or device related shortcomings in its use for treatment of PAD. There are several studies ongoing which aim to further investigate the efficacy of existing SCBs and establish a direct comparison of its outcomes compared with plain balloon angioplasty. Also, SCB utility to salvage failing arteriovenous fistulas for haemodialysis patients has also been explored. We review the current progress made in the establishment of SCB in the treatment of PAD as well as highlight ongoing studies investigating the role of SCB in various settings.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA