Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Acta Orthop ; 94: 416-425, 2023 08 09.
Artículo en Inglés | MEDLINE | ID: mdl-37565339

RESUMEN

BACKGROUND AND PURPOSE: Antibiotic-loaded bone cement (ALBC) and systemic antibiotic prophylaxis (SAP) have been used to reduce periprosthetic joint infection (PJI) rates. We investigated the use of ALBC and SAP in primary total knee arthroplasty (TKA). PATIENTS AND METHODS: This observational study is based on 2,971,357 primary TKAs reported in 2010-2020 to national/regional joint arthroplasty registries in Australia, Denmark, Finland, Germany, Italy, the Netherlands, New Zealand, Norway, Romania, South Africa, Sweden, Switzerland, the UK, and the USA. Aggregate-level data on trends and types of bone cement, antibiotic agents, and doses and duration of SAP used was extracted from participating registries. RESULTS: ALBC was used in 77% of the TKAs with variation ranging from 100% in Norway to 31% in the USA. Palacos R+G was the most common (62%) ALBC type used. The primary antibiotic used in ALBC was gentamicin (94%). Use of ALBC in combination with SAP was common practice (77%). Cefazolin was the most common (32%) SAP agent. The doses and duration of SAP used varied from one single preoperative dosage as standard practice in Bolzano, Italy (98%) to 1-day 4 doses in Norway (83% of the 40,709 TKAs reported to the Norwegian arthroplasty register). CONCLUSION: The proportion of ALBC usage in primary TKA varies internationally, with gentamicin being the most common antibiotic. ALBC in combination with SAP was common practice, with cefazolin the most common SAP agent. The type of ALBC and type, dose, and duration of SAP varied among participating countries.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Infecciones Relacionadas con Prótesis , Humanos , Antibacterianos/uso terapéutico , Artroplastia de Reemplazo de Rodilla/efectos adversos , Cementos para Huesos/uso terapéutico , Cefazolina , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/prevención & control , Infecciones Relacionadas con Prótesis/tratamiento farmacológico , Gentamicinas , América del Norte , Europa (Continente) , Oceanía , África
2.
Medicina (Kaunas) ; 58(6)2022 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-35744095

RESUMEN

Background and Objectives: Even after the 'death' of Lewinnek's safe zone, the orientation of the prosthetic cup in total hip arthroplasty is crucial for success. Accurate cup placement can be achieved with surgical navigation systems. The literature lacks study cohorts with large numbers of hips because postoperative computer tomography is required for the reproducible evaluation of the acetabular component position. To overcome this limitation, we used a validated software program, HipMatch, to accurately assess the cup orientation based on an anterior-posterior pelvic X-ray. The aim of this study were to (1) determine the intraoperative 'individual adjustment' of the cup positioning compared to the widely suggested target values of 40° of inclination and 15° of anteversion, and evaluate the (2) 'accuracy', (3) 'precision', and (4) robustness, regarding systematic errors, of an image-free navigation system in routine clinical use. Material and Methods: We performed a retrospective, accuracy study in a single surgeon case series of 367 navigated primary total hip arthroplasties (PiGalileoTM, Smith+Nephew) through an anterolateral approach performed between January 2011 and August 2018. The individual adjustments were defined as the differences between the target cup orientation (40° of inclination, 15° of anteversion) and the intraoperative registration with the navigation software. The accuracy was the difference between the intraoperative captured cup orientation and the actual postoperative cup orientation determined by HipMatch. The precision was analyzed by the standard deviation of the difference between the intraoperative registered and the actual cup orientation. The outliers were detected using the Tukey method. Results: Compared to the target value (40° inclination, 15° anteversion), the individual adjustments showed that the cups are impacted in higher inclination (mean 3.2° ± 1.6°, range, (−2)−18°) and higher anteversion (mean 5.0° ± 7.0°, range, (−15)−23°) (p < 0.001). The accuracy of the navigated cup placement was −1.7° ± 3.0°, ((−15)−11°) for inclination, and −4.9° ± 6.2° ((−28)−18°) for anteversion (p < 0.001). Precision of the system was higher for inclination (standard deviation SD 3.0°) compared to anteversion (SD 6.2°) (p < 0.001). We found no difference in the prevalence of outliers for inclination (1.9% (7 out of 367)) compared to anteversion (1.63% (6 out of 367), p = 0.78). The Bland-Altman analysis showed that the differences between the intraoperatively captured final position and the postoperatively determined actual position were spread evenly and randomly for inclination and anteversion. Conclusion: The evaluation of an image-less navigation system in this large study cohort provides accurate and reliable intraoperative feedback. The accuracy and the precision were inferior compared to CT-based navigation systems particularly regarding the anteversion. However the assessed values are certainly within a clinically acceptable range. This use of image-less navigation offers an additional tool to address challenging hip prothesis in the context of the hip−spine relationship to achieve adequate placement of the acetabular components with a minimum of outliers.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Cirugía Asistida por Computador , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Humanos , Estudios Retrospectivos , Cirugía Asistida por Computador/métodos
3.
J Arthroplasty ; 34(7S): S201-S208, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31031156

RESUMEN

BACKGROUND: The JOURNEY II Bi-Cruciate Stabilizing Total Knee System (BLINDED) is a second-generation guided-motion knee implant that has been used in over 100,000 primary total knee arthroplasties (TKAs) worldwide. However, performance information is limited. METHODS: Data for 2059 primary TKAs were abstracted at 7 US and 3 European sites. Estimates of cumulative incidence of revision were compared with registry data for cemented posterior-stabilized implants. RESULTS: Average age was 64.3 years (range, 18-91); 58.5% were females; and 12.3% TKAs were in subjects younger than 55 years. Patellae were resurfaced in 95.9%. Median time since primary TKA was 4.2 years; longest was 6.1 years; and 78.9% were 3 years or more since primary TKA. Of 67 revisions (3.2%), 20 (30%) involved femoral or tibial component removal compared to 42% in the Australian Joint Registry (Australian Orthopedic Association National Joint Replacement Registry). All-component revisions accounted for 15 of 67, femoral component only for 2 of 67, tibial component only for 3 of 67, patellar component with/without tibial insert exchange for 17 of 67, and isolated tibial insert exchange for 30 of 67. In addition, there were 18 reoperations without component exchange. Component revision indications were infection (33%), mechanical loosening (21%), fracture of bone around the joint (16%), and instability (15%). Kaplan-Meier revision estimate was 3.1 and 3.6 per 100 TKAs at 3 and 5 years, respectively, compared to Australian Orthopedic Association National Joint Replacement Registry estimates of 3.1 and 4.1 per 100 TKAs. CONCLUSION: The revision rate for the second-generation implant was similar to cemented posterior-stabilized registry controls.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Artroplastia de Reemplazo de Rodilla/métodos , Diseño de Prótesis , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/efectos adversos , Europa (Continente) , Femenino , Fémur/cirugía , Humanos , Internacionalidad , Estimación de Kaplan-Meier , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla/efectos adversos , Masculino , Persona de Mediana Edad , Rótula/cirugía , Falla de Prótesis , Infecciones Relacionadas con Prótesis , Sistema de Registros , Reoperación/efectos adversos , Tibia/cirugía , Estados Unidos , Adulto Joven
4.
Arch Orthop Trauma Surg ; 138(11): 1591-1599, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30167859

RESUMEN

INTRODUCTION: Total knee arthroplasty (TKA) can provide pain relief and good long-term results. However, nearly 30% of post-surgical patients are unsatisfied due to persistent pain and functional deficits. A second-generation bi-cruciate stabilized TKA device has a post-cam mechanism with an asymmetric femoral component, a polyethylene insert, and a medially concave and laterally convex shape. The device is designed to provide guided motion, and thus improve knee kinematics by more closely approximating a normal knee. The aim of this study was to evaluate early complication and revision rates of the second-generation device and to compare its clinical performance to the first-generation device. MATERIALS AND METHODS: In this retrospective, longitudinal, non-concurrent cohort study, 140 TKAs were performed using the second-generation device on 131 patients from 2012 to 2016, and 155 TKAs were performed using the first-generation device on 138 patients from 2009 to 2012. Primary outcomes were occurrence of revisions and reoperations. RESULTS: There were 31 reoperations [3.21 per 100 observed component years (OCY)] in 22 (2.28 per 100 OCY) TKAs in the first-generation device cohort compared to five reoperations (1.92 per 100 OCY) in four TKAs (1.54 per 100 OCY) in the second-generation device cohort. The adjusted hazard ratio (HR) was 3.50 (P = 0.0254). There were 21 revisions (2.17 per 100 OCY) in 16 (1.66 per 100 OCY) TKAs in the first-generation device cohort, compared to only three revisions (1.15 per 100 OCY) in two TKAs (0.77 per 100 OCY) in the second-generation device cohort. The adjusted HR was 4.16 (P = 0.0693). CONCLUSION: The improved design of the second-generation device appears to be associated with a lower risk of reoperation and revision compared to that of the first-generation device. LEVEL OF EVIDENCE: III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla/efectos adversos , Falla de Prótesis/efectos adversos , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Estudios de Cohortes , Femenino , Humanos , Estimación de Kaplan-Meier , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Reoperación/estadística & datos numéricos , Estudios Retrospectivos , Riesgo
5.
BMC Musculoskelet Disord ; 15: 395, 2014 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-25424844

RESUMEN

BACKGROUND: The Journey bicruciate substituting (BCS) total knee replacement (TKR) is intended to improve knee kinematics by more closely approximating the surfaces of a normal knee. The purpose of this analysis was to address the safety of Journey BCS knees by studying early complication and revision rates in a consecutive case series. METHODS: Between December 2006 and May 2011, a single surgeon implanted 226 Journey BCS total knee prostheses in 191 patients (124 women, 67 men) who were eligible for study. Mean age at surgery was 68 years (41-85 years).Outcome measures were early complications and minor and major revision rates. All complications were considered, irrespective of whether conservative treatment or revision was required. RESULTS: The average implantation time was 3.5 years (range 1.3-5.8 years). Thirty-three complications (14.6% of 226 knees) required minor or major revision surgery in 25 patients. The remaining eight patients were treated conservatively. Sixteen minor revisions were performed in 12 patients. Thirteen major revisions were required in 13 patients, which results in a rate of 1.65 major revisions per 100 component years. The linear trend of the early complication rate by treatment year was not significant (p = .22).Multivariate logistic regression showed no significant predictors for the occurrence of a complication or for revision surgery. A tendency towards higher complication rates was observed in female patients, although it was not significant (p = .066). CONCLUSIONS: The complication and revision rates of the Journey BCS knee implant are high in comparison with those reported for other established total knee systems. Caution is advised when using this implant, particularly for less experienced knee surgeons.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/tendencias , Prótesis de la Rodilla/tendencias , Complicaciones Posoperatorias/epidemiología , Falla de Prótesis/efectos adversos , Falla de Prótesis/tendencias , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico , Reoperación/tendencias , Estudios Retrospectivos , Resultado del Tratamiento
6.
BMC Musculoskelet Disord ; 15: 435, 2014 Dec 16.
Artículo en Inglés | MEDLINE | ID: mdl-25515192

RESUMEN

BACKGROUND: The main goals of the standard treatment for advanced symptomatic knee osteoarthritis, total knee arthroplasty (TKA), are pain reduction and restoration of knee motion.The aim of this study was to analyse the outcome of the patient-based Knee Injury and Osteoarthritis Outcome Score (KOOS), and the surgeon-based Knee Society Score (KSS) and its Knee Score (KS) and Knee Functional Score (KFS) components after (TKA) using the Journey knee prosthesis, and to assess the correlation of these scores with range of motion (ROM). METHODS: In a prospective case series study between August 1st 2008 and May 31st 2011, 99 patients, all operated by a single surgeon, received Journey bicruciate stabilized total knee prostheses. The female/male ratio was 53/34, the mean patient age at surgery was 68 years (range 41-83 years), and the left/right knee ratio was 55/44. The KOOS, range of motion, and KS and KFS were obtained preoperatively and at 1-year follow-up. The pre- and postoperative levels of the outcome measures were compared using the Wilcoxon signed-rank test. Correlation between ROM and patient outcomes was analysed with the Spearman coefficient. RESULTS: All KOOS subscores improved significantly. Ninety percent of patients improved by at least the minimum clinically relevant difference of 10 points in stiffness and other symptoms, 94.5% in pain, 94.5% in activities of daily living, 84.9% in sports and recreation, and 90% in knee-related quality of life. The mean passive and active ROM improved from 122.4° (range 90-145°) and 120.4° (range 80-145°) preoperatively to 129.4° (range 90-145°) and 127.1° (range 100-145°) postoperatively. The highest correlation coefficients for ROM and KOOS were observed for the activity and pain subscores. Very low or no correlation was seen for the sport subscore.There was a significant and clinically relevant improvement of KSS (preop/postop 112.2/174.5 points), and its KS (preop/postop 45.6/86.8 points) and KFS (preop/postop 66.6/87.8 points) components. CONCLUSIONS: The Journey bicruciate stabilized knee prosthesis showed good 1-year postoperative results in terms of both functional and patient-based outcome. However, higher knee ROM correlates only moderately with patient-based outcome, implying that functionality afforded by the Journey bicruciate TKA is not equivalent to patient satisfaction.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Osteoartritis de la Rodilla/diagnóstico , Osteoartritis de la Rodilla/cirugía , Recuperación de la Función/fisiología , Autoinforme , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/normas , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Autoinforme/normas , Factores de Tiempo , Resultado del Tratamiento
7.
Rev Med Suisse ; 15(636): 297-298, 2019 Jan 30.
Artículo en Alemán | MEDLINE | ID: mdl-30724518
8.
Orthopadie (Heidelb) ; 53(4): 255-264, 2024 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-38451274

RESUMEN

BACKGROUND: Preserving both cruciate ligaments in knee prosthetics enables approximately physiological joint kinematics. In this way, faster rehabilitation and a higher return-to-sports rate can be achieved. Accordingly, there are considerations to preserve both cruciate ligaments by combining two partial prostheses in the case of symptomatic bicompartmental (BiCom) knee osteoarthritis. METHODS: This article summarizes the literature on BiCom arthroplasty and describes our own experiences from 54 consecutive cases with robotic-assisted technology. RESULTS: According to current data, BiCom arthroplasty shows good clinical results, without being able to demonstrate a clear advantage over conventional TKA. The revision risk is slightly increased in the short-term interval, which could be positively addressed with robotic-assistance. The disadvantages are the increased implant costs and the risk of subsequent osteoarthritis. Accordingly, patients who may potentially take advantage of this treatment must be critically selected.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Ligamento Cruzado Anterior/cirugía , Artroplastia de Reemplazo de Rodilla/efectos adversos , Osteoartritis de la Rodilla/cirugía , Articulación de la Rodilla/cirugía
9.
JAMA Netw Open ; 7(5): e2412898, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38780939

RESUMEN

Importance: Despite increased use of antibiotic-loaded bone cement (ALBC) in joint arthroplasty over recent decades, current evidence for prophylactic use of ALBC to reduce risk of periprosthetic joint infection (PJI) is insufficient. Objective: To compare the rate of revision attributed to PJI following primary total knee arthroplasty (TKA) using ALBC vs plain bone cement. Design, Setting, and Participants: This international cohort study used data from 14 national or regional joint arthroplasty registries in Australia, Denmark, Finland, Germany, Italy, New Zealand, Norway, Romania, Sweden, Switzerland, the Netherlands, the UK, and the US. The study included primary TKAs for osteoarthritis registered from January 1, 2010, to December 31, 2020, and followed-up until December 31, 2021. Data analysis was performed from April to September 2023. Exposure: Primary TKA with ALBC vs plain bone cement. Main Outcomes and Measures: The primary outcome was risk of 1-year revision for PJI. Using a distributed data network analysis method, data were harmonized, and a cumulative revision rate was calculated (1 - Kaplan-Meier), and Cox regression analyses were performed within the 10 registries using both cement types. A meta-analysis was then performed to combine all aggregated data and evaluate the risk of 1-year revision for PJI and all causes. Results: Among 2 168 924 TKAs included, 93% were performed with ALBC. Most TKAs were performed in female patients (59.5%) and patients aged 65 to 74 years (39.9%), fully cemented (92.2%), and in the 2015 to 2020 period (62.5%). All participating registries reported a cumulative 1-year revision rate for PJI of less than 1% following primary TKA with ALBC (range, 0.21%-0.80%) and with plain bone cement (range, 0.23%-0.70%). The meta-analyses based on adjusted Cox regression for 1 917 190 TKAs showed no statistically significant difference at 1 year in risk of revision for PJI (hazard rate ratio, 1.16; 95% CI, 0.89-1.52) or for all causes (hazard rate ratio, 1.12; 95% CI, 0.89-1.40) among TKAs performed with ALBC vs plain bone cement. Conclusions and Relevance: In this study, the risk of revision for PJI was similar between ALBC and plain bone cement following primary TKA. Any additional costs of ALBC and its relative value in reducing revision risk should be considered in the context of the overall health care delivery system.


Asunto(s)
Antibacterianos , Artroplastia de Reemplazo de Rodilla , Cementos para Huesos , Infecciones Relacionadas con Prótesis , Sistema de Registros , Reoperación , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Cementos para Huesos/uso terapéutico , Femenino , Anciano , Masculino , Antibacterianos/uso terapéutico , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/etiología , Reoperación/estadística & datos numéricos , Persona de Mediana Edad , Estudios de Cohortes
10.
J Pers Med ; 13(4)2023 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-37109018

RESUMEN

The accurate positioning of the prosthetic components is essential for achieving successful results in medial unicompartmental knee arthroplasty (mUKA). The tibial component rotation in image-based robotic-assisted UKA is usually based on tibial bony landmarks matched to the pre-operative CT model. The study aimed to evaluate whether setting the tibial rotation on femoral CT-based landmarks allows congruent knee kinematics. We retrospectively analyzed data from 210 consecutive image-based robotic-assisted mUKA cases. In every case, we set the tibia rotation landmark parallel to the posterior condylar axis and centered it on the trochlea groove defined on the preoperative CT scan. The implant positioning was primarily set parallel to this rotation landmark and then adjusted based on tibial sizes avoiding component over- or under-hang. During surgery, we recorded the knee kinematics under valgus stress to reduce the arthritic deformity. A femoral-tibial contact point was recorded over the entire range of motion and displayed as a tracking profile on the tibia implant. The femoro-tibial tracking angle (FTTA) was then calculated based on a tangent line to the femoro-tibial tracking-points and the difference to the femur-based rotation landmark. In 48% of the cases, we could position the tibia component exactly to the femoral rotation landmark, whereas in 52% of cases, minimal adjustments were made to avoid component's under- or over-hang. The mean tibia component rotation (TRA) with reference to our femur-based landmark was +0.24° (SD ± 2.9°). The femur-based tibia rotation landmark showed a high correspondence to the FTTA with 60% of the cases having less than 1° of deviation. Mean FTTA was +0.7° (SD ± 2.2°). The mean difference between the absolute value of the TRA and the FTTA (|TRA| - |FTTA|) was -0.18° (SD ± 2°). Setting the tibial component rotation based on CT scan femoral landmarks and not on tibial anatomical landmarks is a reliable method to obtain congruent knee kinematics during image-based robotic-assisted medial UKA with less the 2° deviations on average.

11.
J Pers Med ; 13(5)2023 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-37241038

RESUMEN

The aims of this study were to evaluate the outcomes of patients undergoing kinematic alignment (KA) robot-assisted (RA) total knee arthroplasty (TKA) with and without preoperative fixed flexion contracture (FFC) and address whether additional resection of the proximal tibia is required to address FFC. A retrospective review from 147 consecutive patients who received an RA-TKA with KA and a minimum one-year follow-up was performed. Preop and postop clinical and surgical data were collected. Groups were set based on preoperative extension deficits: group 1 (0-4°) (n = 64), group 2 (5-10°) (n = 64) and group 3 (>11°) (n = 27). There were no differences in patient demographics among the three groups. In group 3, the mean tibia resection was 0.85 mm thicker than group 1 (p < 0.05) and the preoperative extension deficit was improved from -17.22° (SD 3.49) preop to -2.41° (SD 4.47) postop (p < 0.05). Our results demonstrate that FFC can successfully be addressed in the RA-TKA with KA and rKA and that no additional femoral bone resection is needed to achieve full extension in patients with preoperative FFC when compared with patients without FFC. Only a slight increase in the amount of tibial resection was observed, but this was less than one millimetre.

12.
Knee Surg Sports Traumatol Arthrosc ; 20(3): 503-9, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21630048

RESUMEN

PURPOSE: The relative advantages of cruciate retaining or cruciate resecting total knee replacement are still controversial. If the posterior cruciate ligament (PCL) is preserved, it should be properly balanced. In a previous study, it was demonstrated that increasing the flexion gap leads to an anterior translation of the tibia relative to the femur. Based on these results, we hypothesized that cutting the PCL increases the flexion gap and lessens anterior tibial translation. METHODS: The amount of anterior tibial translation versus distraction force in the flexion gap was measured in 88 total knee replacements with a less invasive midvastus approach using a custom-made tensioner. Measurements were performed with intact and resected PCL. RESULTS: The difference in tibial translation with and without PCL is not significant. A 1-mm increase in the flexion gap led to an average anterior translation of 0.6 mm with intact PCL and 0.4 mm with cut PCL, which is less than that reported in a previous study. CONCLUSIONS: The results have not confirmed our initial hypothesis. The reasons for this may be other soft tissue structures that prevent anterior tibial translation, such as the collateral ligaments, and/or the extensor apparatus. Moreover, the knee flexion angle for the used specific implant may play a role. LEVEL OF EVIDENCE: Prospective comparative study, Level II.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Ligamento Cruzado Posterior/cirugía , Tibia/fisiopatología , Anciano , Artroplastia de Reemplazo de Rodilla/instrumentación , Femenino , Humanos , Inestabilidad de la Articulación/fisiopatología , Masculino , Osteoartritis de la Rodilla/fisiopatología , Osteoartritis de la Rodilla/cirugía
13.
J Pers Med ; 12(2)2022 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-35207672

RESUMEN

Several computer-assisted technologies, such as navigation and robotics, have been introduced to Total Knee Arthroplasty (TKA) in order to increase surgical precision and reduce complications. However, these technologies are often criticized due to the increased costs and effort associated with them; however, comparative data are missing. The aim of the present study was to evaluate differences in intraoperative workflows and the related perioperative cost-profiles of four current computer-assisted technologies, used to implant a TKA, in order to gain a comparison to conventional instrumentation. For the cost analysis, additional preoperative imaging and instruments, increased operating room (OR) and planning-time, and expenditures for technical support of the equipment and disposals were calculated, in comparison to conventional TKA, for (1) standard computer-navigation, (2) patient specific instruments (PSI), (3) image-based robotic assistance, and (4) imageless robotic assistance. Workflows at four expert centers which use these technologies were reviewed by an independent observer. The total cost calculation was based on a 125 TKA per year unit in Switzerland. Computer-navigation resulted in 14 min (+23%) increased surgery time and, overall, USD 650 in additional costs. PSI technology saved 5 min (8%) OR time but it created USD 1520 in expenditures for imaging and disposals. The image-based robotic system was the most expensive technology; it created overall additional costs of USD 2600, which predominately resulted from technical support, disposals, the CT-Scan, and 14 min of increased OR time. The imageless robotic assistance resulted in the largest increase in OR-time, as it resulted in an additional 25 min (+42%) on average. Overall, additional costs of USD 1530 were calculated. Every one of the assistive technologies in this study increased the total cost of TKA when compared to a conventional technique, and the most important variables, related to cost, were technical support and additional disposables. The longer surgical times and additional surgical trays required for the techniques had a marginal effect on overall costs. This comparative cost analysis gives valuable information for future efforts to calculate the real costs of these technologies and the subsequent return on investment of each technique.

14.
J Pers Med ; 11(7)2021 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-34357129

RESUMEN

INTRODUCTION: Image-based robotic assistance appears to be a promising tool for individualizing alignment in total knee arthroplasty (TKA). The patient-specific model of the knee enables a preoperative 3D planning of component position. Adjustments to the individual soft-tissue situation can be done intraoperatively. Based on this, we have established a standardized workflow to implement the idea of kinematic alignment (KA) for robotic-assisted TKA. In addition, we have defined limits for its use. If these limits are reached, we switch to a restricted KA (rKA). The aim of the study was to evaluate (1) in what percentage of patients a true KA or an rKA is applicable, (2) whether there were differences regarding knee phenotypes, and (3) what the differences of philosophies in terms of component position, joint stability, and early patient outcome were. METHODS: The study included a retrospective analysis of 111 robotic-assisted primary TKAs. Based on preoperative long leg standing radiographs, the patients were categorized into a varus, valgus, or neutral subgroup. Initially, all patients were planned for KA TKA. When the defined safe zone had been exceeded, adjustments to an rKA were made. Intraoperatively, the alignment of the components and joint gaps were recorded by robotic software. RESULTS AND CONCLUSION: With our indication for TKA and the defined boundaries, "only" 44% of the patients were suitable for a true KA with no adjustments or soft tissue releases. In the varus group, it was about 70%, whereas it was 0% in the valgus group and 25% in the neutral alignment group. Thus, significant differences with regard to knee morphotypes were evident. In the KA group, a more physiological knee balance reconstructing the trapezoidal flexion gap (+2 mm on average laterally) was seen as well as a closer reconstruction of the surface anatomy and joint line in all dimensions compared to rKA. This resulted in a higher improvement in the collected outcome scores in favor of KA in the very early postoperative phase.

16.
Arch Orthop Trauma Surg ; 128(2): 129-35, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18075748

RESUMEN

INTRODUCTION: Posterior cruciate ligament (PCL)-retaining prostheses give good outcomes and are commonly used. This retrospective study investigated outcomes from total knee arthroplasty (TKA) using the ligament balancing technique to implant a PCL-retaining knee prosthesis (balanSystrade mark knee system) with either a mobile or a fixed bearing polyethylene inlay. MATERIALS AND METHODS: A retrospective study was performed on patients treated with TKA at one surgical centre between 1997 and 2001. In this period 182 surgeries were performed. Clinical assessments of the implant used the Knee Society Score (KSS). Subjective assessments used visual analogue scale (VAS) for pain and patient satisfaction. The Western Ontario and McMasters Universities Osteoarthritis Index (WOMAC) was used to assess pain, stiffness and function of the knee. Radiographic analysis was performed to determine frontal and sagittal alignment and loosening. RESULTS: A total of 109 knee implants in 95 patients (26 men; 69 women) were followed up. Seventy-three cases were not available for follow-up due to bad health or death of the patient; 74% of 109 reviewed implants had fixed bearings and 26% had mobile bearings. The mean age at surgery was 72.9 +/- 7.35 years (range 54.7-92.4). The mean KSS was 160 +/- 28.3 points. The KSS was greater for men and was significantly reduced when another disease was present. The type of bearing, surgical approach, and pre-operative alignment for patients affected by varus or valgus gonarthrosis had no significant impact on KSS and ROM. According to VAS the mean scores for pain and satisfaction were 1.48 (0 = no pain) and 9.2 (10 = very satisfied), respectively. The WOMAC mean scores for pain (87.0), stiffness (82.3) and function (78.6) were high (best outcome score of 100). There were no revisions due to aseptic loosening or wear. CONCLUSION: Total knee arthroplasty performed with a PCL-retaining prosthesis implanted by using a soft tissue oriented surgical technique is a safe procedure and was associated with good results. So far, there were few complications and no need for revision due to aseptic loosening. In addition, most of the patients reported little pain and were satisfied with the outcome. These good outcomes are comparable with other studies reporting on PCL-retaining prostheses.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Prótesis de la Rodilla , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Satisfacción del Paciente , Implantación de Prótesis/métodos , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS