RESUMEN
The usefulness of mouthwash as a transport medium for cervical specimens for carcinogenic human papillomavirus (HPV) DNA testing has not been evaluated. Two cervical specimens were collected from each of 34 patients, with one placed in mouthwash (Scope, Proctor and Gamble, Inc.) and the other in a liquid cytology medium commonly used for HPV DNA testing in alternating order. Paired specimens were tested by a PCR assay for carcinogenic HPV and a PCR HPV genotyping assay for 37 HPV types at 0, 3, and 6 weeks after collection; the results of the HPV genotyping assay were categorized into HPV risk groups according to cancer risk (HPV-16 > HPV-18 > other carcinogenic HPV types > noncarcinogenic HPV types > negative). After 4 months of storage, specimens were tested using a second, non-PCR test for carcinogenic HPV. We observed a >or=94% total agreement and kappa values of >or=0.88 between media at each time point for PCR-detected carcinogenic HPV. We observed a >or=74% total agreement, >or=0.62 unweighted kappa, and >or=0.75 linearly weighted kappa between media at each time point for PCR-detected HPV cancer risk category. Finally, we observed an 88% total agreement and kappa of 0.77 between media for carcinogenic HPV detection using a second test after 4 months of storage. We suggest that mouthwash might be used as a low-cost, safe, nonflammable storage and transport medium for cervical specimens for HPV DNA testing in cervical cancer screening programs.
Asunto(s)
Cetilpiridinio , ADN Viral/análisis , Papillomaviridae/aislamiento & purificación , Infecciones por Papillomavirus/diagnóstico , Compuestos de Amonio Cuaternario , Manejo de Especímenes/métodos , Neoplasias del Cuello Uterino/virología , Distribución de Chi-Cuadrado , Combinación de Medicamentos , Femenino , HumanosRESUMEN
We evaluated a more efficient method of processing liquid-based cervical cytology specimens for human papillomavirus (HPV) DNA testing by Hybrid Capture II (HCII). Aliquots were made from 701 specimens in the following sequence: 4.0, 2.0, 1.0, 0.5, and 1.5 mL. The 4.0-mL aliquot was processed by the standard method (STP), and half of the processed material was tested by HCII. Other aliquots were processed with a new, filtration-based processing method (NPM). The 2.0-mL NPM aliquot had HCII test performance most similar to the STP, ie, similar HCII positivity (P = .4) and good test agreement (kappa = 0.85, 95% confidence interval [CI], 0.80-0.89). The 194 cytologic negatives had greater positivity by STP (P = .04) compared with the 2.0-mL aliquot processed by NPM; between-method agreement was modest (kappa = 0.54, 95% CI, 0.36-0.72). A lower positive cut point for the 2.0-mL NPM aliquot partially abrogated this minor difference. In 241 specimens diagnosed as low-grade and 31 as high-grade squamous intraepithelial lesions, there were no significant differences in HPVpositivity (>85% and 90%, respectively) between STP and NPM. NPM reduces specimen handling and decreases total testing time by approximately 33% without significant losses in HCII test performance.