Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Sci Rep ; 13(1): 362, 2023 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-36611055

RESUMEN

Radiation source localization and characterization are challenging tasks that currently require complex analyses for interpretation. Mixed reality (MR) technologies are at the verge of wide scale adoption and can assist in the visualization of complex data. Herein, we demonstrate real-time visualization of gamma ray and neutron radiation detector data in MR using the Microsoft HoloLens 2 smart glasses, significantly reducing user interpretation burden. Radiation imaging systems typically use double-scatter events of gamma rays or fast neutrons to reconstruct the incidence directional information, thus enabling source localization. The calculated images and estimated 'hot spots' are then often displayed in 2D angular space projections on screens. By combining a state-of-the-art dual particle imaging system with HoloLens 2, we propose to display the data directly to the user via the head-mounted MR smart glasses, presenting the directional information as an overlay to the user's 3D visual experience. We describe an open source implementation using efficient data transfer, image calculation, and 3D engine. We thereby demonstrate for the first time a real-time user experience to display fast neutron or gamma ray images from various radioactive sources set around the detector. We also introduce an alternative source search mode for situations of low event rates using a neural network and simulation based training data to provide a fast estimation of the source's angular direction. Using MR for radiation detection provides a more intuitive perception of radioactivity and can be applied in routine radiation monitoring, education & training, emergency scenarios, or inspections.

2.
Med Phys ; 48(10): 6137-6151, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34431520

RESUMEN

PURPOSE: Electron-based ultra-high dose rate radiation therapy (UHDR-RT), also known as Flash-RT, has shown the ability to improve the therapeutic index in comparison to conventional radiotherapy (CONV-RT) through increased sparing of normal tissue. However, the extremely high dose rates in UHDR-RT have raised the need for accurate real-time dosimetry tools. This work aims to demonstrate the potential of the emerging technology of Ionized Radiation Acoustic Imaging (iRAI) through simulation studies and investigate its characteristics as a promising relative in vivo dosimetric tool for UHDR-RT. METHODS: The detection of induced acoustic waves following a single UHDR pulse of a modified 6 MeV 21EX Varian Clinac in a uniform porcine gelatin phantom that is brain-tissue equivalent was simulated for an ideal ultrasound transducer. The full 3D dose distributions in the phantom for a 1 × 1 cm2 field were simulated using EGSnrc (BEAMnrc∖DOSXYZnrc) Monte Carlo (MC) codes. The relative dosimetry simulations were verified with dose experimental measurements using Gafchromic films. The spatial dose distribution was converted into an initial pressure source spatial distribution using the medium-dependent dose-pressure relation. The MATLAB-based toolbox k-Wave was then used to model the propagation of acoustic waves through the phantom and perform time-reversal (TR)-based imaging reconstruction. The effect of the various linear accelerator (linac) operating parameters, including linac pulse duration and pulse repetition rate (frequency), were investigated as well. RESULTS: The MC dose simulation results agreed with the film measurement results, specifically at the central beam region up to 80% dose within approximately 5% relative error for the central profile region and a local relative error of <6% for percentage dose depth. IRAI-based FWHM of the radiation beam was within approximately 3 mm relative to the MC-simulated beam FWHM at the beam entrance. The real-time pressure signal change agreed with the dose changes proving the capability of the iRAI for predicting the beam position. IRAI was tested through 3D simulations of its response to be based on the temporal changes in the linac operating parameters on a dose per pulse basis as expected theoretically from the pressure-dose proportionality. The pressure signal amplitude obtained through 2D simulations was proportional to the dose per pulse. The instantaneous pressure signal amplitude decreases as the linac pulse duration increases, as predicted from the pressure wave generation equations, such that the shorter the linac pulse the higher the signal and the better the temporal (spatial) resolutions of iRAI. The effect of the longer linac pulse duration on the spatial resolution of the 3D constructed iRAI images was corrected for linac pulse deconvolution. This correction has improved the passing rate of the 1%/1 mm gamma test criteria, between the pressure-constructed and dosimetric beam characteristics, to as high as 98%. CONCLUSIONS: A full simulation workflow was developed for testing the effectiveness of iRAI as a promising relative dosimetry tool for UHDR-RT radiation therapy. IRAI has shown the advantage of 3D dose mapping through the dose signal linearity and, hence, has the potential to be a useful dosimeter at depth dose measurement and beam localization and, hence, potentially for in vivo dosimetry in UHDR-RT.


Asunto(s)
Aceleradores de Partículas , Radiometría , Acústica , Animales , Método de Montecarlo , Fantasmas de Imagen , Radiación Ionizante , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Porcinos
3.
Sci Rep ; 10(1): 1855, 2020 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-32024927

RESUMEN

A compact radiation imaging system capable of detecting, localizing, and characterizing special nuclear material (e.g. highly-enriched uranium, plutonium…) would be useful for national security missions involving inspection, emergency response, or war-fighters. Previously-designed radiation imaging systems have been large and bulky with significant portions of volume occupied by photomultiplier tubes (PMTs). The prototype imaging system presented here uses silicon photomultipliers (SiPMs) in place of PMTs because SiPMs are much more compact and operate at low power and voltage. The SiPMs are coupled to the ends of eight stilbene organic scintillators, which have an overall volume of 5.74 × 5.74 × 7.11 cm3. The prototype dual-particle imager's capabilities were evaluated by performing measurements with a 252Cf source, a sphere of 4.5 kg of alpha-phase weapons-grade plutonium known as the BeRP ball, a 6 kg sphere of neptunium, and a canister of 3.4 kg of plutonium oxide (7% 240Pu and 93% 239Pu). These measurements demonstrate neutron spectroscopic capabilities, a neutron image resolution for a Watt spectrum of 9.65 ± 0.94° in the azimuthal direction and 22.59 ± 5.81° in the altitude direction, imaging of gamma rays using organic scintillators, and imaging of multiple sources in the same field of view.

4.
IEEE Access ; 8: 111347-111354, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-34192107

RESUMEN

The outbreak of the novel coronavirus disease, COVID-19 turned into a global pandemic in March 2020. During these unprecedented times, there is an increased demand in medical and personal protective equipment (PPE). Since the supplies may take a long time to meet the global demand, reusing PPEs will help health care workers in their response to the COVID-19 pandemic. To ensure the safety and well-being of the medical first responders, PPE needs to be sterilized before reuse. In this review, we examine various sterilization techniques that can be used to sterilize PPEs and point out its limitations. The objective is to provide a foundation of knowledge incorporating different sterilization techniques that allow hospitals and clinics to pick the most suitable technique for sterilization of a particular PPE.

5.
Sci Rep ; 10(1): 6811, 2020 04 22.
Artículo en Inglés | MEDLINE | ID: mdl-32321941

RESUMEN

We propose a sparsity-promoting Bayesian algorithm capable of identifying radionuclide signatures from weak sources in the presence of a high radiation background. The proposed method is relevant to radiation identification for security applications. In such scenarios, the background typically consists of terrestrial, cosmic, and cosmogenic radiation that may cause false positive responses. We evaluate the new Bayesian approach using gamma-ray data and are able to identify weapons-grade plutonium, masked by naturally-occurring radioactive material (NORM), in a measurement time of a few seconds. We demonstrate this identification capability using organic scintillators (stilbene crystals and EJ-309 liquid scintillators), which do not provide direct, high-resolution, source spectroscopic information. Compared to the EJ-309 detector, the stilbene-based detector exhibits a lower identification error, on average, owing to its better energy resolution. Organic scintillators are used within radiation portal monitors to detect gamma rays emitted from conveyances crossing ports of entry. The described method is therefore applicable to radiation portal monitors deployed in the field and could improve their threat discrimination capability by minimizing "nuisance" alarms produced either by NORM-bearing materials found in shipped cargoes, such as ceramics and fertilizers, or radionuclides in recently treated nuclear medicine patients.

6.
Sci Rep ; 8(1): 14986, 2018 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-30279557

RESUMEN

A correction to this article has been published and is linked from the HTML and PDF versions of this paper. The error has not been fixed in the paper.

7.
Radiat Prot Dosimetry ; 180(1-4): 355-359, 2018 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-29149320

RESUMEN

We developed a radiation detector based on an organic scintillator for spectrometry and dosimetry of out-of-field secondary neutrons from clinical proton beams. The detector consists of an EJ-299-34 crystalline organic scintillator, coupled by fiber optic cable to a silicon photomultiplier (SiPM). Proof of concept measurements were taken with 137Cs and 252Cf, and corresponding simulations were performed in MCNPX-PoliMi. Despite its small size, the detector is able to discriminate between neutron and gamma-rays via pulse shape discrimination. We simulated the response function of the detector to monoenergetic neutrons in the 100 keV-0 MeV range using MCNPX-PoliMi. The measured unfolded 252Cf neutron spectrum is in good agreement with the theoretical Watt fission spectrum. We determined the ambient dose equivalent by folding the spectrum with the fluence-to-ambient dose conversion coefficient, with a 1.4% deviation from theory. Some preliminary proton beam experiments were preformed at the Bronowice Cyclotron Center patient treatment facility using a clinically relevant proton pencil beam for brain tumor and craino-spinal treatment directed at a child phantom.


Asunto(s)
Neoplasias Encefálicas/radioterapia , Californio/análisis , Radioisótopos de Cesio/análisis , Neutrones , Fantasmas de Imagen , Conteo por Cintilación/instrumentación , Niño , Preescolar , Simulación por Computador , Humanos , Dosificación Radioterapéutica
8.
Sci Rep ; 7(1): 7997, 2017 08 11.
Artículo en Inglés | MEDLINE | ID: mdl-28801550

RESUMEN

The detection and characterization of highly enriched uranium (HEU) presents a large challenge in the non-proliferation field. HEU has a low neutron emission rate and most gamma rays are low energy and easily shielded. To address this challenge, an instrument known as the dual-particle imager (DPI) was used with a portable deuterium-tritium (DT) neutron generator to detect neutrons and gamma rays from induced fission in HEU. We evaluated system response using a 13.7-kg HEU sphere in several configurations with no moderation, high-density polyethylene (HDPE) moderation, and tungsten moderation. A hollow tungsten sphere was interrogated to evaluate the response to a possible hoax item. First, localization capabilities were demonstrated by reconstructing neutron and gamma-ray images. Once localized, additional properties such as fast neutron energy spectra and time-dependent neutron count rates were attributed to the items. For the interrogated configurations containing HEU, the reconstructed neutron spectra resembled Watt spectra, which gave confidence that the interrogated items were undergoing induced fission. The time-dependent neutron count rate was also compared for each configuration and shown to be dependent on the neutron multiplication of the item. This result showed that the DPI is a viable tool for localizing and confirming fissile mass and multiplication.

9.
Radiat Environ Biophys ; 44(3): 225-33, 2005 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-16261368

RESUMEN

Following a significant increase in the number of facilities in the world having and developing low- and high-linear energy transfer (LET) microbeams for experimental radiobiological studies, it is useful and demanding to establish reliable computational models to analyze such experiments. This paper summarizes initial MCNP5 calculations of the basic parameters needed to study X-ray microbeam penetration, dose deposition and dose spatial dissipation in tissue-like media of micro and macro scales. The presented models can be used to predict doses delivered to neighboring cells and analyze the cause of bystander cell deaths. In the case of low-LET radiation, dose distribution is more homogenized when compared to high-LET that deposits almost all of its energy in the cell hit by radiation. Results are presented for a microbeam of monoenergetic soft (2-10 keV) X-rays for two different micro-models: (a) single-cells of homogeneous and uniform chemical compositions, and (b) single-cells of heterogeneous structures (nucleus and cytoplasm) with different chemical compositions. In both numerical models, only one cell is irradiated and the electron and X-ray doses in all cells are recorded. It was found that surrounding cells receive approximately five orders of magnitude less dose than the target cell in the homogenized cell model. The more detailed, heterogeneous model showed that the nucleus of the target cell receives more than 95% of the dose delivered to the entire cell, while neighboring cell nuclei receive approximately 65% of their total cell dose. Results of the macroscopic behavior of a soft X-ray microbeam using a cylindrical phantom 5 cm tall and 1 cm in diameter are also presented. Three-dimensional dose profiles indicate the spatial dose dissipation. For example, a 10 keV X-ray microbeam dose scatters to a negligible level at 0.3 cm radially from the center while it reaches an axial depth of 2 cm.


Asunto(s)
Tejido Conectivo/fisiología , Modelos Biológicos , Radiometría/métodos , Programas Informáticos , Rayos X , Algoritmos , Carga Corporal (Radioterapia) , Simulación por Computador , Tejido Conectivo/efectos de la radiación , Transferencia Lineal de Energía/fisiología , Dosis de Radiación , Efectividad Biológica Relativa , Dispersión de Radiación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA