1.
Phys Rev Lett ; 120(13): 132504, 2018 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-29694208

RESUMEN

A new method to tag the barium daughter in the double-beta decay of ^{136}Xe is reported. Using the technique of single molecule fluorescent imaging (SMFI), individual barium dication (Ba^{++}) resolution at a transparent scanning surface is demonstrated. A single-step photobleach confirms the single ion interpretation. Individual ions are localized with superresolution (∼2 nm), and detected with a statistical significance of 12.9σ over backgrounds. This lays the foundation for a new and potentially background-free neutrinoless double-beta decay technology, based on SMFI coupled to high pressure xenon gas time projection chambers.

2.
Eur Phys J C Part Fields ; 84(5): 518, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38784120

RESUMEN

Noble element time projection chambers are a leading technology for rare event detection in physics, such as for dark matter and neutrinoless double beta decay searches. Time projection chambers typically assign event position in the drift direction using the relative timing of prompt scintillation and delayed charge collection signals, allowing for reconstruction of an absolute position in the drift direction. In this paper, alternate methods for assigning event drift distance via quantification of electron diffusion in a pure high pressure xenon gas time projection chamber are explored. Data from the NEXT-White detector demonstrate the ability to achieve good position assignment accuracy for both high- and low-energy events. Using point-like energy deposits from 83mKr calibration electron captures (E∼45 keV), the position of origin of low-energy events is determined to 2 cm precision with bias <1mm. A convolutional neural network approach is then used to quantify diffusion for longer tracks (E≥1.5 MeV), from radiogenic electrons, yielding a precision of 3 cm on the event barycenter. The precision achieved with these methods indicates the feasibility energy calibrations of better than 1% FWHM at Qßß in pure xenon, as well as the potential for event fiducialization in large future detectors using an alternate method that does not rely on primary scintillation.

3.
J Chem Phys ; 133(12): 124316, 2010 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-20886941

RESUMEN

A new experimental technique for measuring the mobilities of positive ions in their parent gases is presented. The technique was applied to the rare gases, Ar, Kr, and Xe, and, for pressures typically below 10 Torr, two different types of positive ions were observed. The reduced mobilities of these ions in their parent gases were measured as a function of E/N, the ratio of the electric field strength to the gas number density, at a temperature of 300±1 K. The results were compared with others available in the literature and the two ions were identified as being the atomic and the dimer rare gas ions. The results are in good agreement with those from other authors. Space charge and impurities effects are discussed.