Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Eur Radiol ; 31(7): 5189-5197, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33409792

RESUMEN

OBJECTIVES: Radiofrequency ablation (RFA) is effective in reducing the volume of benign thyroid nodules. However, what parameters can influence the response to RFA is still unclear. The present study aimed to (1) investigate which ultrasound and technical parameters are potential determinants of the volumetric reduction; (2) develop a dose-response model, and (3) analyze the effects of RFA on ultrasound features. METHODS: In this retrospective study, three institutions treated patients with benign thyroid nodules according to the same protocol. The technical parameters were power and energy. The 1-year volume reduction ratio (VRR) was the reference standard of the response. The correlations of different parameters with VRR were analyzed and the association between several parameters and a VRR above 50% studied by uni- and multivariate analyses. The probit regression estimated the probability to achieve an effective response. RESULTS: One hundred fifteen patients were enrolled. The median power was 50 W and median total delivered energy 27,531 J. At 1-year follow-up, the median VRR was 64.0% and 87 (75.7%) nodules showed a VRR above 50%. Among all parameters, only baseline volume, total energy, and energy per volume were independently associated to a VRR > 50% (p = 0.001, p = 0.0178, p < 0.001 respectively). The probit regression analysis demonstrated that delivering 756 J/ml and 2670 J/ml gave a probability of VRR > 50% in 50% and 99% of patients, respectively. CONCLUSIONS: Considering the baseline nodular volume and delivering the adequate energy per volume allow optimizing technical and clinical success. KEY POINTS: • The effectiveness of radiofrequency ablation in treating benign thyroid nodules is negatively correlated to the volume of the nodule and positively correlated to the energy delivered per volume. • When planning the treatment, the total energy to deliver can be calculated by using a simple formula: nodular volume × 2670 J.


Asunto(s)
Ablación por Catéter , Ablación por Radiofrecuencia , Nódulo Tiroideo , Humanos , Estudios Retrospectivos , Nódulo Tiroideo/diagnóstico por imagen , Nódulo Tiroideo/cirugía , Resultado del Tratamiento , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA