1.
Ophthalmology ; 131(7): 855-863, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38185285

RESUMEN

TOPIC: This systematic review examined geographical and temporal trends in medical school ophthalmology education in relationship to course and student outcomes. CLINICAL RELEVANCE: Evidence suggesting a decline in ophthalmology teaching in medical schools is increasing, raising concern for the adequacy of eye knowledge across the rest of the medical profession. METHODS: Systematic review of Embase and SCOPUS, with inclusion of studies containing data on medical school ophthalmic course length; 1 or more outcome measures on student ophthalmology knowledge, skills, self-evaluation of knowledge or skills, or student course appraisal; or both. The systematic review was registered prospectively on the International Prospective Register of Systematic Reviews (identifier, CRD42022323865). Results were aggregated with outcome subgroup analysis and description in relationship to geographical and temporal trends. Descriptive statistics, including nonparametric correlations, were used to analyze data and trends. RESULTS: Systematic review yielded 4596 publication titles, of which 52 were included in the analysis, with data from 19 countries. Average course length ranged from 12.5 to 208.7 hours, with significant continental disparity among mean course lengths. Africa reported the longest average course length at 103.3 hours, and North America reported the shortest at 36.4 hours. On average, course lengths have been declining over the last 2 decades, from an average overall course length of 92.9 hours in the 2000s to 52.9 hours in the 2020s. Mean student self-evaluation of skills was 51.3%, and mean student self-evaluation of knowledge was 55.4%. Objective mean assessment mark of skills was 57.5% and that of knowledge was 71.7%, compared with an average pass mark of 66.7%. On average, 26.4% of students felt confident in their ophthalmology knowledge and 34.5% felt confident in their skills. DISCUSSION: Most evidence describes declining length of courses devoted to ophthalmology in the last 20 years, significant student dissatisfaction with courses and content, and suboptimal knowledge and confidence. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Asunto(s)
Oftalmología , Facultades de Medicina , Oftalmología/educación , Humanos , Competencia Clínica , Curriculum , Educación de Pregrado en Medicina/tendencias , Estudiantes de Medicina , Evaluación Educacional
2.
J Neuroophthalmol ; 2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38715188

RESUMEN

BACKGROUND: Visual changes due to hyperglycemia in diabetes are not uncommon. While blurred vision is a well-established sequela of chronic hyperglycemia, homonymous hemianopia with or without electroclinical seizures is much rarer and can be mistaken for migraine, temporal arteritis, or ischemia of the central nervous system. METHODS: This article analyzed case studies for 3 patients (67M, 68M, 52F) presenting with complex visual phenomena, from 3 to 42 days duration, including pathogenesis, clinical findings, management, and follow-up. RESULTS: Examinations demonstrated dense left homonymous hemianopias in 2 patients and a left inferior homonymous quadrantanopia in one, with no other abnormalities. Patients described vivid, nonstereotyped intermittent hallucinations in the affected fields. Blood glucose levels ranged from 13.5 to 35.0 mmol/L (243-630 mg/dL) without ketosis and HbA1c from 14.6% to 16.8%. Computed tomography of the brain showed no acute intracranial pathology. MRI of the brain either detected no abnormalities or demonstrated changes consistent with seizure activity. Electroencephalogram (EEG) demonstrated seizures over the right occipital region in each patient. EEG seizures coincided with patients' hallucinations, while they remained otherwise conscious. Oral hypoglycemic and antiepileptic medications were commenced with rapid and complete reversal of the seizures and visual field deficits, confirmed by repeat Automated 30-2 and MRI. CONCLUSIONS: Hyperglycemia-induced occipital lobe seizures with visual hallucinations and interictal homonymous visual field defects represent a rare but clinically important diagnosis. This article highlights the importance of prompt recognition and treatment to facilitate recovery.

3.
Ann Biomed Eng ; 52(4): 898-907, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38155316

RESUMEN

Glaucoma surgery with implantation of aqueous humor draining microstents may compromise long-term corneal health by disrupting aqueous humor circulation. The effect of stent numbers on this circulation was interrogated to determine the number of stents associated with minimal circulation disruption. An in vitro anterior eye model perfusion system was constructed with multiple exit ports. A 3-D model of the anterior eye was imported into ABAQUS CFD, analyzes were carried out for unsteady laminar flow and solved using Navier-Stokes equations. DT Vision Foundry was used to analyze velocity contour plot images. The field variable results output for the CFD model were fluid wall shear, fluid pressure and fluid velocity. In vitro, "aqueous" fluid flow is high through a single stent and "aqueous" stagnation is greatest in the quadrants 180° away. Increasing stent port numbers, results in an exponential decrease in the stagnant flow locations. High wall shear stress was seen in the single stent model and is markedly reduced after a second and subsequent stents are introduced. We identify two factors potentially contributing to corneal compromise post glaucoma drainage surgery: aqueous humor stagnation, remote to the stent site and higher exit flows imparting increased stent exit shear stress (particularly with a single stent). With 4 stents, there is minimal disruption of anterior chamber circulation (mimicking physiological conditions). Furthermore we propose that aqueous humor circulation disruption via the usual single-exit port approach disrupts aqueous humor circulation with long-term consequences for corneal health.


Asunto(s)
Humor Acuoso , Glaucoma , Humanos , Humor Acuoso/fisiología , Presión Intraocular , Glaucoma/cirugía , Procedimientos Quirúrgicos Mínimamente Invasivos , Perfusión
4.
Cornea ; 43(9): 1072-1079, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38830192

RESUMEN

PURPOSE: Recent advancements in infrared sensing technology have made it possible to visualize tear film dynamics in real time, enabling evaluation of tear film quality during blinking. A retrospective clinical evaluation was conducted to explore this by grading videos of the tear film and comparing grading data with dry eye diagnostic results using the OCULUS keratograph (K5M). METHODS: Videos were used to grade patients' tear film perturbations as compared with healthy control subjects. The grading was then correlated with the ocular surface disease index (OSDI) scores, tear film breakup time (TFBUT), tear meniscus height (TMH), corneal staining, redness, and meibography data. RESULTS: Infrared imaging of the ocular surface revealed instantaneous and recurring dynamic characteristics of the tear film, allowing for the differentiation between normal and abnormal tear films. Abnormal features included a complete absence of a spreading tear film, hindered spreading of the tear film after blinking, areas of tear film instability, or a combination of the latter 2. Some of these features show a resemblance to the tear film appearance after fluorescein staining. The grading of these features correlated with TFBUT and, to a lesser extent, with TMH but did not show significant correlation with any other diagnostic data from the K5M. Furthermore, the speed of tear film spreading after blinking showed a positive correlation with TMH. CONCLUSIONS: Direct visualization of the tear film across the entire palpebral aperture using infrared sensing offers a noninvasive, reproducible, and rapid method for assessing the health and quality of the tear film.


Asunto(s)
Parpadeo , Síndromes de Ojo Seco , Lágrimas , Humanos , Lágrimas/fisiología , Lágrimas/química , Lágrimas/metabolismo , Síndromes de Ojo Seco/diagnóstico , Síndromes de Ojo Seco/metabolismo , Síndromes de Ojo Seco/fisiopatología , Estudios Retrospectivos , Parpadeo/fisiología , Femenino , Masculino , Adulto , Persona de Mediana Edad , Técnicas de Diagnóstico Oftalmológico , Rayos Infrarrojos , Córnea/diagnóstico por imagen , Anciano
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA