Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
J Vasc Interv Radiol ; 17(5): 873-82, 2006 May.
Artículo en Inglés | MEDLINE | ID: mdl-16687754

RESUMEN

PURPOSE: This study was undertaken to evaluate and compare endothelialization of small intestinal submucosa (SIS), Dacron, and expanded polytetrafluoroethylene (ePTFE) in high-pressure flow without aortic wall contact and to evaluate the suitability of SIS as a vascular graft material. MATERIALS AND METHODS: In 12 adult sheep, three types of membrane leaflets of similar thickness (approximately 200 mum) were suspended within large square stents without contact with the thoracoabdominal aortic wall: SIS (n = 12), Dacron (n = 12), and ePTFE (n = 12). Each animal received one leaflet of each material. Aortograms were obtained before and after percutaneous implantation and when the animal was killed at 8 weeks (n = 6) or 18 weeks (n = 6). Cell coverage and remodeling of SIS, Dacron, and ePTFE membranes were assessed by gross and histologic microscopic examinations. RESULTS: Thirty-five successfully implanted leaflets were evaluated. SIS showed progressive remodeling. Thirty-three leaflets exhibited thickening as a result of neointimal formation and endothelialization, most likely from circulating endothelial cells. Dacron exhibited the greatest and most progressing degree of neointimal formation and endothelialization, followed by SIS and then ePTFE. With SIS and ePTFE, neointimal formation decreased with time, but endothelialization was stable. Uneven neointimal formation and endothelialization on the outer surfaces and distal leaflet positions were seen. CONCLUSIONS: SIS showed progressive remodeling with moderate and regressive neointimal formation and moderate stable endothelialization. Further study of its durability and incorporation into the aortic wall needs to be performed to evaluate its suitability as a cover for aortic endografts.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Prótesis Vascular , Mucosa Intestinal/trasplante , Tereftalatos Polietilenos , Politetrafluoroetileno , Animales , Aneurisma de la Aorta Abdominal/patología , Materiales Biocompatibles , Implantación de Prótesis Vascular/métodos , Endotelio Vascular/citología , Femenino , Intestino Delgado , Diseño de Prótesis , Ovinos
2.
Cardiovasc Intervent Radiol ; 29(5): 838-45, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16779691

RESUMEN

The purpose of this study was to investigate how the restriction of blood flow and/or ventilation affects the radiofrequency (RF) ablation coagulation size in lung parenchyma. Thirty-one RF ablations were done in 16 normal lungs of 8 living swine with 2-cm LeVeen needles. Eight RF ablations were performed as a control (group G1), eight with balloon occlusion of the ipsilateral mainstem bronchus (G2), eight with occlusion of the ipsilateral pulmonary artery (G3), and seven with occlusion of both the ipsilateral bronchus and pulmonary artery (G4). Coagulation diameters and volumes of each ablation zone were compared on computed tomography (CT) and gross specimen examinations. Twenty-six coagulation zones were suitable for evaluation: eight in G1, five in G2, seven in G3, and six in G4 groups. In G1, the mean coagulation diameter was 21.5 +/- 3.5 mm on CT and 19.5 +/- 1.78 mm on gross specimen examination. In G2, the mean diameters were 26.5 +/- 5.1 mm and 23.0 +/- 2.7 mm on CT and gross specimen examination, respectively. In G3, the mean diameters were 29.4 +/- 2.2 mm and 27.4 +/- 2.9 mm on CT and gross specimen examination, respectively, and in G4, they were 32.6 +/- 3.33 mm and 28.8 +/- 2.6 mm, respectively. The mean coagulation volumes were 3.39 +/- l.52 cm(3) on CT and 3.01 +/- 0.94 cm(3) on gross examinations in G1, 6.56 +/- 2.47 cm(3) and 5.22 +/- 0.85 cm(3) in G2, 10.93 +/- 2.17 cm(3) and 9.97 +/- 2.91 cm(3) in G3, and 13.81 +/- 3.03 cm(3) and 11.06 +/- 3.27 cm(3) in G4, respectively. The mean coagulation diameters on gross examination and mean coagulation volumes on CT and gross examination with G3 and G4 were significantly larger than those in G1 (p < 0.0001, p < 0.0001, p < 0.0001, respectively) or in G2 (p < 0.05, p < 0.005, p < 0.005, respectively). Pulmonary collapse occurred in one lung in G2 and pulmonary artery thrombus in two lungs of G3 and two lungs of G4. The coagulation size of RF ablation of the lung parenchyma is increased by ventilation and particularly by pulmonary artery blood flow restriction. The value of these restrictions for potential clinical use needs to be explored in experimentally induced lung tumors.


Asunto(s)
Ablación por Catéter , Pulmón/cirugía , Respiración , Animales , Broncoconstricción , Pulmón/irrigación sanguínea , Pulmón/diagnóstico por imagen , Pulmón/patología , Necrosis , Sus scrofa , Tomografía Computarizada por Rayos X
3.
J Vasc Interv Radiol ; 16(11): 1505-9, 2005 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-16319158

RESUMEN

Long-term retrievability of a new optional retrieval inferior vena cava (IVC) filter composed of a modified square stent and a modified Günther Tulip filter was tested in eight sheep. Eleven filters were placed into the IVC and eight were successfully retrieved 3-5 months after implantation. Incorporation of the filter struts into the IVC wall prevented its retrieval in three sheep at 3, 4, and 5 months after placement.


Asunto(s)
Remoción de Dispositivos , Filtros de Vena Cava , Vena Cava Inferior/cirugía , Animales , Implantación de Prótesis Vascular , Modelos Animales de Enfermedad , Femenino , Estudios de Seguimiento , Flebografía , Diseño de Prótesis/clasificación , Ovinos , Stents/clasificación , Factores de Tiempo , Grado de Desobstrucción Vascular , Vena Cava Inferior/diagnóstico por imagen , Vena Cava Inferior/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA