1.
J Trauma Acute Care Surg ; 94(1): 148-155, 2023 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-35687798

RESUMEN

BACKGROUND: Gastroesophageal resuscitative occlusion of the aorta (GROA) has been shown effective in creating zone II aortic occlusion capable of temporarily improving survival in animal models of lethal noncompressible torso hemorrhage. In this study, tandem application of GROA transitioning to resuscitative endovascular balloon occlusion of the aorta (REBOA) is explored to demonstrate feasibility as a potential point-of-injury bridge to more advanced care, using a swine model of lethal abdominal hemorrhage. METHODS: Swine (n = 19) were anesthetized, instrumented, and subjected to a combination of controlled and uncontrolled hemorrhage from a grade-V liver laceration. Animals were designated as intervention (n = 9; GROA to REBOA) or control (n = 10), for 60 minutes. Following intervention, devices were deactivated, and animals received blood and crystalloid resuscitation. Animals were monitored for 4 hours. RESULTS: Injury resulted in onset of class IV shock in all animals with a mean arterial pressure (SD) of 24.5 (4.11) mm Hg at the start of intervention. Nine of 10 controls died during the intervention period with a median (interquartile) survival time of 8.5 (9.25) minutes. All animals receiving the intervention survived both the 60-minute intervention period demonstrating a significant survival improvement ( p = 0.0007). Transition from GROA to REBOA was successful in all animals with a transition time ranging from 30 to 90 seconds. Mean arterial pressure significantly improved in animals receiving GROA to REBOA for the duration of intervention, regardless of the method of aortic occlusion, with a range of 70.9 (16.04) mm Hg to 101.1 (15.3) mm Hg. Additional hemodynamics, metrics of shock, and oxygenation remained stable during intervention. CONCLUSION: Less invasive technologies such as GROA may present an opportunity to control noncompressible torso hemorrhage more rapidly, with a subsequent transition to more advanced care such as REBOA.


Asunto(s)
Oclusión con Balón , Procedimientos Endovasculares , Laceraciones , Choque Hemorrágico , Porcinos , Animales , Modelos Animales de Enfermedad , Aorta/lesiones , Hemorragia/terapia , Hígado/lesiones , Oclusión con Balón/métodos , Resucitación/métodos , Procedimientos Endovasculares/métodos , Choque Hemorrágico/terapia
2.
Resuscitation ; 189: 109885, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37385400

RESUMEN

AIM: To investigate the effect of tandem use of transient balloon occlusion of the descending aorta (AO) and percutaneous left ventricular assist device (pl-VAD) during cardiopulmonary resuscitation in a large animal model of prolonged cardiac arrest. METHODS: Ventricular fibrillation was induced and left untreated for 8 minutes followed by 16 minutes of mechanical CPR (mCPR) in 24 swine, under general anesthesia. Animals were randomized to 3 treatment groups (n = 8 per group): A) pL-VAD (Impella CP®) B) pL-VAD+AO, and C) AO. Impella CP® and the aortic balloon catheter were inserted via the femoral arteries. mCPR was continued during treatment. Defibrillation was attempted 3 times starting at minute 28 and then every 4 minutes. Haemodynamic, cardiac function and blood gas measurements were recorded for up to 4 hours. RESULTS: Coronary perfusion pressure (CoPP) in the pL-VAD+AO Group increased by a mean (SD) of 29.2(13.94) mmHg compared to an increase of 7.1(12.08) and 7.1(5.95) mmHg for groups pL-VAD and AO respectively (p = 0.02). Similarly, cerebral perfusion pressure (CePP) in pL-VAD+AO increased by a mean (SD) of 23.6 (6.11), mmHg compared with 0.97 (9.07) and 6.9 (7.98) mmHg for the other two groups (p < 0.001). The rate of return of spontaneous heartbeat (ROSHB) was 87.5%, 75%, and 100% for pL-VAD+AO, pL-VAD, and AO. CONCLUSION: Combined AO and pL-VAD improved CPR hemodynamics compared to either intervention alone in this swine model of prolonged cardiac arrest.


Asunto(s)
Oclusión con Balón , Reanimación Cardiopulmonar , Paro Cardíaco , Corazón Auxiliar , Animales , Modelos Animales de Enfermedad , Paro Cardíaco/terapia , Hemodinámica , Porcinos , Fibrilación Ventricular/terapia
3.
Resuscitation ; 193: 110010, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37884220

RESUMEN

BACKGROUND: It remains unclear if percutaneous left ventricular assist device (pLVAD) reduces post-cardiac arrest myocardial dysfunction. METHODS: This is a prespecified analysis of a subset of swine that achieved return of spontaneous circulation (ROSC) in a study comparing pLVAD, transient aortic occlusion (AO), or both during cardiopulmonary resuscitation (CPR). Devices were initiated after 24 minutes of ventricular fibrillation cardiac arrest (8 min no-flow and 16 min mechanical CPR). AO was discontinued post-ROSC, and pLVAD support or standard care were continued. Beginning 60 minutes post-ROSC, pLVAD support was weaned to < 1.0 L/min and subsequently removed at 240 minutes. The primary outcome was cardiac index (CI), stroke volume index (SVI), and left ventricular ejection fraction (LVEF) at 240 minutes post-ROSC. Data are shown as mean (standard error). RESULTS: Seventeen swine achieved ROSC without complication and were included in this analysis (pLVAD group, n = 11 and standard care group, n = 6). For the primary outcomes, the pLVAD group had significantly higher CI of 4.2(0.3) vs. 3.1(0.4) L/min/m2 (p = 0.043) and LVEF 60(3) vs. 49(4) % (p = 0.029) at 240 minutes after ROSC when compared with the standard care group, while SVI was not statistically significantly different (32[3] vs. 23[4] mL/min/m2, p = 0.054). During the first 60 minutes post-ROSC, the pLVAD group had significantly higher coronary perfusion pressure, lower LV stroke work index, and total pulmonary resistance index. CONCLUSION: These results suggest that early pLVAD support after ROSC is associated with better recovery myocardial function compared to standard care after prolonged cardiac arrest.


Asunto(s)
Reanimación Cardiopulmonar , Paro Cardíaco , Corazón Auxiliar , Animales , Porcinos , Volumen Sistólico , Función Ventricular Izquierda , Paro Cardíaco/complicaciones , Perfusión/efectos adversos , Reanimación Cardiopulmonar/métodos , Fibrilación Ventricular/complicaciones , Modelos Animales de Enfermedad
4.
Resusc Plus ; 16: 100488, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38143529

RESUMEN

Background: Recent studies describe an emerging role for percutaneous left ventricular assist devices such as Impella CP® as rescue therapy for refractory cardiac arrest. We hypothesized that the addition of mechanical chest compressions to percutaneous left ventricular assist device assisted CPR would improve hemodynamics by compressing the right ventricle and augmenting pulmonary blood flow and left ventricular filling. We performed a pilot study to test this hypothesis using a swine model of prolonged cardiac arrest. Methods: Eight Yorkshire swine were anesthetized, intubated, and instrumented for hemodynamic monitoring. They were subjected to untreated ventricular fibrillation for 5.75 (SD 2.90) minutes followed by mechanical chest compressions for a mean of 20.0 (SD 5.0) minutes before initiation of percutaneous left ventricular assist device. After percutaneous left ventricular assist device initiation, mechanical chest compressions was stopped (n = 4) or continued (n = 4). Defibrillation was attempted 4, 8 and 12 minutes after initiating percutaneous left ventricular assist device circulatory support. Results: The percutaneous left ventricular assist device + mechanical chest compressions group had significantly higher percutaneous left ventricular assist device flow prior to return of spontaneous heartbeat at four- and twelve-minutes after percutaneous left ventricular assist device initiation, and significantly higher end tidal CO2 at 4-minutes after percutaneous left ventricular assist device initiation, when compared with the percutaneous left ventricular assist device alone group. Carotid artery flow was not significantly different between the two groups. Conclusion: The addition of mechanical chest compressions to percutaneous left ventricular assist device support during cardiac arrest may generate higher percutaneous left ventricular assist device and carotid artery flow prior to return of spontaneous heartbeat compared to percutaneous left ventricular assist device alone. Further studies are needed to determine if this approach improves other hemodynamic parameters or outcomes after prolonged cardiac arrest.