Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
BMC Musculoskelet Disord ; 24(1): 880, 2023 Nov 11.
Artículo en Inglés | MEDLINE | ID: mdl-37951888

RESUMEN

PURPOSE: Ankle fracture-dislocations are among the most severe injuries, and the use of an external fixator as a recommended fixation method has some disadvantages. The aim of this study was to compare the clinical outcomes and complication rates of external and K-wire fixations in the treatment of ankle fracture dislocations. METHODS: A total of 67 patients with ankle fracture-dislocations requiring temporary external or percutaneous K-wire fixation were included. The exclusion criteria were pilon fractures, open fractures, and those who required acute open reduction internal fixation (ORIF). The American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, a 10-point visual analog scale (VAS) score (range 0-10), and complications before and after the definitive surgery were recorded. RESULTS: A significant difference between the two groups was not observed for age, sex, affected side, fracture type, smoking status, or diabetes. The average AOFAS scores were 83.2 and 83.3, the median VAS scores were 3 and 3, and the complication rates were 32.4% and 6.7% in the external and K-wire fixation groups, respectively (p = 0.010). However, skin necrosis, re-dislocation of the ankle, surgical wound infection, and posttraumatic ankle osteoarthritis frequency were not significantly different between the groups, except for pin-sites infection (p = 0.036). CONCLUSION: Ankle fracture-dislocations using percutaneous k-wire fixation showed a low rate of complications and favorable clinical outcomes. This method could be a good alternative treatment option for ankle fracture-dislocations.


Asunto(s)
Fracturas de Tobillo , Fractura-Luxación , Humanos , Fracturas de Tobillo/diagnóstico por imagen , Fracturas de Tobillo/cirugía , Fracturas de Tobillo/etiología , Tobillo , Resultado del Tratamiento , Fijación de Fractura/efectos adversos , Fijación de Fractura/métodos , Fijadores Externos/efectos adversos , Fractura-Luxación/diagnóstico por imagen , Fractura-Luxación/cirugía , Fractura-Luxación/etiología , Fijación Interna de Fracturas/efectos adversos , Estudios Retrospectivos
2.
Foot Ankle Surg ; 28(7): 872-878, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34916143

RESUMEN

BACKGROUND: We compared the effectiveness of the extensile lateral approach (ELA) and modified sinus tarsi approach (MSTA) with a variable-angle locking anterolateral plate in treating Sanders type II and III calcaneal fractures. METHODS: We reviewed 45 DIACFs treated by a single surgeon from 2017 to 2020. Open reduction using ELA and MSTA was performed in 25 and 20 patients, respectively. Follow-up evaluations included radiological assessments and clinical evaluations. RESULTS: Pre- and postoperative radiologic parameters for the calcaneus were significantly different. The average American Orthopaedic Foot and Ankle Society scores were 81.24 and 85.00, the mean visual analogue scale scores were 2.28 and 1.65, and the wound-related complication rates were 64.0% and 15.0% in the ELA and MSTA groups, respectively. Bony union was achieved in all cases. CONCLUSIONS: For Sanders type II and III fractures, MSTA seems to be a safer and more satisfactory method, with fewer postoperative complications.


Asunto(s)
Traumatismos del Tobillo , Calcáneo , Traumatismos de los Pies , Fracturas Óseas , Fracturas Intraarticulares , Placas Óseas , Calcáneo/diagnóstico por imagen , Calcáneo/cirugía , Traumatismos de los Pies/cirugía , Fijación Interna de Fracturas/métodos , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía , Talón , Humanos , Fracturas Intraarticulares/diagnóstico por imagen , Fracturas Intraarticulares/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
3.
BMC Musculoskelet Disord ; 20(1): 511, 2019 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-31679513

RESUMEN

BACKGROUND: Proximal humeral fractures (PHFs) are the third most commonly occurring fractures in elderly patients. Most of these fractures can be treated with conservative methods, but the optimal surgical treatment strategy for unstable fractures in elderly patients remains controversial. This study aimed to compare the radiological and clinical outcomes between locking compression plate (LCP) fixation and LCP fixation with fibular allograft implantation for the treatment of comminuted PHFs. METHODS: We retrospectively reviewed 60 patients (mean age, 72.75 years) with closed 3- or 4-part fractures, and a minimum of 2 years of follow-up. Fracture reduction was quantitatively determined by humeral head height (HHH) and neck-shaft angle (NSA). The clinical outcome was evaluated by Constant-Murley score (CMS) and American Shoulder and Elbow Surgeons (ASES) score. RESULT: The average radiological changes were higher in the LCP group than in the locking plate with fibular allograft group (HHH of 4.16 mm vs 1.18 mm [p < 0.001] and NSA of 9.94° versus 3.12° [p < 0.001]) . The final average outcome scores were lower in the LCP group than in the FA group (CMS of 73.00 vs 78.96 [p = 0.024] and ASES score of 72.80 vs 78.64 [p = 0.022]). The FA group showed better forward elevation (p = 0.010) and abduction (p = 0.002); however, no significant differences were observed for shoulder external rotation or internal rotation. The number of complications was higher in the LCP group (28.57%) than in the FA group (1.2%) (p < 0.001). CONCLUSION: For comminuted PHFs in elderly patients, LCP fixation combined with a fibular allograft is reasonable option to ensure satisfactory radiological and clinical outcomes. TRIAL REGISTRATION: ZDYJLY(2018)New-9 . Name of registry: IEC for clinical Research of Zhongda Hospital, Affiliated to Southeast University. Date of registration: 2018-05-17.


Asunto(s)
Placas Óseas , Trasplante Óseo/métodos , Peroné/trasplante , Fijación Interna de Fracturas/métodos , Fracturas del Hombro/diagnóstico por imagen , Fracturas del Hombro/cirugía , Anciano , Placas Óseas/tendencias , Trasplante Óseo/tendencias , Estudios de Cohortes , Femenino , Fijación Interna de Fracturas/tendencias , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Trasplante Homólogo/métodos , Trasplante Homólogo/tendencias
4.
J Immunol ; 197(6): 2131-44, 2016 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-27527600

RESUMEN

IL-35 downregulates Th17 cell development and suppresses certain types of autoimmune inflammation such as collagen-induced arthritis and experimental autoimmune uveitis. Psoriasis is thought to be initiated by abnormal interactions between cutaneous keratinocytes and systemic immune cells. However, the role of IL-35 in psoriasis remains unclear. In this study, we assessed IL-35 in three well-known psoriasis models: a human keratinocyte cell line (HaCaT), a keratin 14 (K14)-vascular endothelial growth factor A (VEGF-A)-transgenic (Tg) mouse model, and an imiquimod-induced psoriasis mouse model. First, we found that IL-35 suppressed the expression of IL-6, CXCL8, and S100A7, which are highly upregulated by a mixture of five proinflammatory cytokines in HaCaT. Second, a plasmid coding for the human IL-35 sequence coated with cationic liposomes showed potent immunosuppressive effects on K14-VEGF-A-Tg and imiquimod-induced psoriasis mouse models. In the K14-VEGF-A-Tg model, our results showed that several types of proinflammatory cytokines were significantly reduced, whereas IL-10 was remarkably induced by IL-35. Compared with pcDNA3.1, there was a small number of CD4(+)IL-17(+) T cells and a large number of CD4(+)IL-10(+) and CD4(+)CD25(+)Foxp3(+) T cells in the IL-35 group. Most importantly, we found that IL-35 decreased the total number of macrophages and ratio of M1/M2 macrophages, which has not been reported previously. In addition, compared with dexamethasone, IL-35 showed long-term therapeutic efficacy. In summary, our results strongly indicate that IL-35 plays a potent immunosuppressive role in psoriasis. Thus, IL-35 has potential for development as a new therapeutic strategy for patients with chronic psoriasis and other cutaneous inflammatory diseases.


Asunto(s)
Citocinas/biosíntesis , Inflamación/tratamiento farmacológico , Interleucinas/farmacología , Macrófagos/efectos de los fármacos , Psoriasis/tratamiento farmacológico , Animales , Células Cultivadas , Dexametasona/farmacología , Humanos , Inflamación/inmunología , Interleucina-6/biosíntesis , Interleucina-8/biosíntesis , Interleucinas/uso terapéutico , Queratinocitos/metabolismo , Macrófagos/fisiología , Ratones , Ratones Endogámicos BALB C , Psoriasis/inmunología , Proteína A7 de Unión a Calcio de la Familia S100 , Proteínas S100/biosíntesis , Células Th17/efectos de los fármacos , Células Th17/fisiología
6.
Nanomicro Lett ; 17(1): 5, 2024 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-39304561

RESUMEN

Li-CO2 batteries are considered promising energy storage systems in extreme environments such as Mars; however, severe performance degradation will occur at a subzero temperature owning to the sluggish reaction kinetics. Herein, a photo-energized strategy adopting sustainable solar energy in wide working temperature range Li-CO2 battery was achieved with a binder-free MoS2/carbon nanotube (CNT) photo-electrode as cathode. The unique layered structure and excellent photoelectric properties of MoS2 facilitate the abundant generation and rapid transfer of photo-excited carriers, which accelerate the CO2 reduction and Li2CO3 decomposition upon illumination. The illuminated battery at room temperature exhibited high discharge voltage of 2.95 V and mitigated charge voltage of 3.27 V, attaining superior energy efficiency of 90.2% and excellent cycling stability of over 120 cycles. Even at an extremely low temperature of - 30 °C, the battery with same electrolyte can still deliver a small polarization of 0.45 V by the photoelectric and photothermal synergistic mechanism of MoS2/CNT cathode. This work demonstrates the promising potential of the photo-energized wide working temperature range Li-CO2 battery in addressing the obstacle of charge overpotential and energy efficiency.

7.
Zhongguo Gu Shang ; 36(3): 226-31, 2023 Mar 25.
Artículo en Zh | MEDLINE | ID: mdl-36946013

RESUMEN

OBJECTIVE: To compare the efficacy of percutaneous compression plate and cannulated compression screw in the treatment of displaced femoral neck fractures in young and middle-aged patients. METHODS: From January 2015 to July 2020, 68 young and middle-aged patients with displaced femoral neck fracture were retrospectively analyzed. Among them, 31 cases were fixed by percutaneous compression plate (PCCP), and 37 cases were fixed by cannulated compression screw (CCS). General data such as gender, age, cause of injury, comorbidities, fracture classification and cause of injury of two groups were collected. The operation time, intraoperative blood loss, hospital stay, full weight bearing time, fracture healing time, visual analogue scale(VAS), Harris hip score and complications were compared between two groups. RESULTS: Patients in both groups were followed up for more than 2 years. There were no significant differences in operation time, intraoperative blood loss, fracture reduction quality, hospital stay and VAS between two groups. The fracture healing time in PCCP group was significantly shorter than that in CCS group (t=-4.404, P=0.000). The complete weight bearing time of PCCP group was significantly shorter than that of CCS group (t=-9.011, P=0.000). Harris score of hip joint in PCCP group was better than that in CCS group 2 years after operation (P=0.002). Complications occurred in 3 cases (9.68%) in PCCP group, while 11 cases (29.72%) in CCS group, with a statistically significant difference (P=0.042). CONCLUSION: Both PCCP and CCS can be used for the treatment of displaced femoral neck fractures in young and middle-aged people. Compared with CCS, PCCP fixation can achieve shorter fracture healing time and create conditions for early full weight bearing. PCCP results in higher hip score and lower complications.


Asunto(s)
Pérdida de Sangre Quirúrgica , Fracturas del Cuello Femoral , Persona de Mediana Edad , Humanos , Resultado del Tratamiento , Estudios Retrospectivos , Fijación Interna de Fracturas/métodos , Fracturas del Cuello Femoral/cirugía , Tornillos Óseos
8.
Chem Commun (Camb) ; 59(10): 1365-1368, 2023 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-36649100

RESUMEN

An amorphous hydrated vanadium oxide induced by Zn2+ intercalation in Mg-ion inserted V2O5·nH2O (MgVOH) is developed as a high-performance cathode for ZIBs. In particular, zinc pyrovanadate as the product of the second phase transition is found to suppress the dissolution issue of the vanadium species for the cathode to facilitate long lifespan.

9.
Comput Methods Biomech Biomed Engin ; 26(7): 846-853, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-35754380

RESUMEN

This study compared the biomechanical characteristics of different treatment strategies based on finite element analysis. Posterior tilt and valgus angle were measured on X-ray from ten valgus-impacted femoral neck fractures, and 7 finite element models that were generated to compare the stress and displacement. The results showed that in the intact femur, von Mises stress was concentrated at the medial and inferior sides of the femoral neck. In valgus-impacted femoral neck fractures, von Mises stress was at the same locations but was 5.66 times higher than that in the intact femur. When 3 cannulated screws were used for internal fixation, anatomic reduction diminished the stress at the fracture end from 140.6 to 59.14 MPa, although displacement increased from 0.228 to 0.450 mm. When the fracture was fixed with a sliding hip screw (SHS) + cannulated screw, there was less stress at the fracture end and greater displacement with anatomic reduction than that without reduction (stress: 15.9 vs 37.9 MPa; displacement: 0.329 vs 0.168 mm). Therefore, the SHS + cannulated screw has superior biomechanical stability than 3 cannulated screws, and is recommended following anatomic reduction to treat valgus-compacted femoral neck fractures.


Asunto(s)
Fracturas del Cuello Femoral , Fijación Interna de Fracturas , Humanos , Análisis de Elementos Finitos , Fijación Interna de Fracturas/métodos , Fracturas del Cuello Femoral/diagnóstico por imagen , Fracturas del Cuello Femoral/cirugía , Fémur , Tornillos Óseos , Fenómenos Biomecánicos
10.
J Orthop Trauma ; 36(9): 445, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-35234733

RESUMEN

OBJECTIVE: To compare the clinical and radiological results of locking plate fixation with and without spine cage for the treatment of unstable proximal humeral fractures in elderly patients. DESIGN: Retrospective study. SETTING: Level 1 Trauma Center. PATIENTS/PARTICIPANTS: A total of 62 patients with a mean age of 72.68 (60-88) years were included. Thirty-nine patients were treated with only a locking compression plate (LCP group), whereas 23 patients were treated with a locking compression plate and a spine cage (SC group). The mean follow-up was 32.26 (24-46) months. MAIN OUTCOME MEASURES: Radiological outcomes were assessed using the humeral head height and neck-shaft angle. The clinical results were evaluated using a visual analog scale for pain, the Constant-Murley score, the American Shoulder and Elbow score, and shoulder range of motion. RESULTS: The average radiological changes in the humeral head height and neck-shaft angle were significantly higher in the LCP group than in the SC group ( P < 0.001 and P < 0.001, respectively). The final outcome scores were lower in the LCP group than in the SC group (Constant-Murley score of 73.26 vs. 78.91 [ P = 0.028] and American Shoulder and Elbow score of 72.36 vs. 78.57 [ P = 0.011]). The SC group showed better forward elevation ( P = 0.005) and abduction ( P = 0.001); however, no significant differences were observed for shoulder external or internal rotation. The number of complications was higher in the LCP group (38.5%) than in the SC group (13.0%) ( P = 0.033). CONCLUSIONS: For unstable proximal humeral fractures with medial comminution in elderly patients, locking plate with an SC is a reasonable option to ensure satisfactory results and lower the postoperative complications. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Fracturas del Húmero , Fracturas del Hombro , Anciano , Placas Óseas , Fijación Interna de Fracturas/métodos , Humanos , Fracturas del Húmero/cirugía , Estudios Retrospectivos , Fracturas del Hombro/diagnóstico por imagen , Fracturas del Hombro/cirugía , Resultado del Tratamiento
11.
Front Bioeng Biotechnol ; 10: 813070, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35480984

RESUMEN

Dysregulation of microRNAs (miRNAs) plays a critical role in the development of intervertebral disc degeneration (IDD). In this study, we present evidence from in vitro and in vivo research to elucidate the mechanism underlying the role of miR-760 in IDD. miRNA microarray and quantitative reverse transcription-polymerase chain reaction were used to determine the miRNA profiles in patients with IDD. Functional analysis was performed to evaluate the role of miR-760 in the pathogenesis of IDD. Luciferase reporter and western blotting assays were used to confirm the miRNA targets. The expression of miR-760 was significantly decreased in degenerative nucleus pulposus (NP) cells and negatively correlated with disc degeneration grade. Functional assays demonstrated that miR-760 delivery significantly increased NP cell proliferation and promoted the expression of collagen II and aggrecan. Moreover, MyD88 was identified as a target gene of miR-760. miR-760 effectively suppressed MyD88 expression by interacting with the 3'-untranslated region, which was abolished by miR-760 binding site mutations. An in vivo experiment using an IDD mouse model showed that the upregulation of miR-760 could effectively suspend IDD. Therefore, miR-760 was found to play an important role in IDD and can be used as a promising therapeutic target for the treatment of patients with IDD.

12.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 36(3): 274-278, 2022 Mar 15.
Artículo en Zh | MEDLINE | ID: mdl-35293166

RESUMEN

Objective: To compare the effectiveness of locking plate and intramedullary nail in treatment of Neer two- and three-part fractures of the proximal humerus in the elderly. Methods: A retrospective analysis was conducted on 86 elderly patients with Neer two- and three-part fractures of the proximal humerus met the selection criteria between January 2015 and December 2018. Forty-six patients were treated with locking plate fixation (locking plate group), and 40 patients with intramedullary nail fixation (intramedullary nail group). There was no significant difference in gender, age, cause of injury, fracture side and type, time from injury to operation, and comorbidities between the two groups ( P>0.05). Visual analogue scale (VAS) score, American Shoulder and Elbow Surgery (ASES) score, Constant-Murley score, and shoulder range of motion (forward flexion, abduction, and external rotation) were compared between the two groups. X-ray films were taken to assess the fracture healing, and the neck-shaft angle was measured at 2 days after operation and at last follow-up, and the difference between the two time points was calculated. Results: Patients in both groups were followed up 18-40 months, with an average of 30.4 months. There was no significant difference in follow-up time between the two groups ( t=-0.986, P=0.327). X-ray films reexamination showed that the fractures of two groups healed, and the healing time was (11.3±2.1) weeks in locking plate group and (10.3±2.0) weeks in intramedullary nail group, which had significant difference between the two groups ( t=2.250, P=0.027). The difference of neck-shaft angle was (7.63±7.01)° in locking plate group and (2.85±2.82)° in intramedullary nail group, which had significant difference between the two groups ( t=4.032, P<0.001). There was no significant difference in Constant-Murley score, ASES score, VAS score, and shoulder range of motion between the two groups at last follow-up ( P>0.05). Complications occurred in 13 cases (28.3%) of locking plate group and in 4 cases (10.0%) of intramedullary nail group, and the difference between the two groups was significant ( χ 2=4.498, P=0.034). Conclusion: Both locking plates and intramedullary nails can be used for the treatment of Neer two- and three-part fractures of the proximal humerus in the elderly. The intramedullary nail fixation surgery is more minimally invasive, which has fewer postoperative complications and faster fracture healing.


Asunto(s)
Fracturas del Hombro , Hombro , Anciano , Clavos Ortopédicos/efectos adversos , Humanos , Húmero , Estudios Retrospectivos , Fracturas del Hombro/cirugía , Resultado del Tratamiento
13.
J Orthop Trauma ; 34(4): e142-e147, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31738236

RESUMEN

Surgical treatment of unstable proximal humeral fractures is challenging in elderly patients. The locking plate technique has been advocated for the management of these fractures in recent years; however, it is still difficult to achieve stable fixation and maintain intra-operative reduction in patients with low bone mineral density. It is generally accepted that a critical step to enhance clinical results and reduce complications is re-creation of the medial column support. Here, we introduce a novel technique using titanium mesh in the treatment of proximal humerus fractures. Although preliminary results have been encouraging, further study with a larger number of patients and longer follow-up is needed to fully validate this technique.


Asunto(s)
Fracturas del Hombro , Titanio , Anciano , Placas Óseas , Fijación Interna de Fracturas , Humanos , Húmero , Fracturas del Hombro/diagnóstico por imagen , Fracturas del Hombro/cirugía , Mallas Quirúrgicas
14.
J Int Med Res ; 47(5): 2045-2055, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30890008

RESUMEN

OBJECTIVE: We herein introduce a staged management protocol for AO/OTA type 43-C3.3 pilon fractures based on the four-column theory designed to protect the soft tissue. METHODS: Twenty-three patients with 25 type C3.3 pilon fractures underwent a staged procedure with four-column osteosynthesis from April 2014 to December 2016. The first stage involved immediate calcaneal traction or external fixation to span the ankle joint. When the soft tissue swelling decreased, the posterolateral approach was used to restore the lateral column and initially fix the posterior column. After 10 to 12 days, the third stage involved treatment of the anterior and medial columns through the anterior approach. Charts and radiographs were reviewed, and the American Orthopaedic Foot and Ankle Society (AOFAS) evaluation system was used to evaluate the postoperative outcomes. RESULTS: All fractures achieved union after a mean of 3.3 months (range, 2.0-5.7 months) after the third stage. A good or acceptable reduction rate was observed in 85.7% of the patients. Results from the AOFAS evaluation system indicated excellent or good postoperative ankle function in 81.0% of the patients. CONCLUSION: This staged procedure protocol combined with the four-column theory is a feasible way to protect the soft tissue and reduce the fracture.


Asunto(s)
Fracturas de Tobillo/cirugía , Adulto , Fracturas de Tobillo/diagnóstico por imagen , Traumatismos del Tobillo/diagnóstico por imagen , Traumatismos del Tobillo/cirugía , Fijadores Externos , Humanos , Masculino , Persona de Mediana Edad , Cuidados Posoperatorios , Complicaciones Posoperatorias/etiología , Tibia/diagnóstico por imagen , Tibia/cirugía
15.
J Int Med Res ; 46(7): 2525-2536, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29916291

RESUMEN

Objectives Two-stage open reduction and internal fixation (ORIF) and limited internal fixation combined with external fixation (LIFEF) are two widely used methods to treat Pilon injury. However, which method is superior to the other remains controversial. This meta-analysis was performed to quantitatively compare two-stage ORIF and LIFEF and clarify which method is better with respect to postoperative complications in the treatment of tibial Pilon fractures. Methods We conducted a meta-analysis to quantitatively compare the postoperative complications between two-stage ORIF and LIFEF. Eight studies involving 360 fractures in 359 patients were included in the meta-analysis. Results The two-stage ORIF group had a significantly lower risk of superficial infection, nonunion, and bone healing problems than the LIFEF group. However, no significant differences in deep infection, delayed union, malunion, arthritis symptoms, or chronic osteomyelitis were found between the two groups. Conclusion Two-stage ORIF was associated with a lower risk of postoperative complications with respect to superficial infection, nonunion, and bone healing problems than LIFEF for tibial Pilon fractures. Level of evidence 2.


Asunto(s)
Fracturas de Tobillo/cirugía , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/métodos , Fracturas de la Tibia/cirugía , Fijadores Externos/efectos adversos , Fijación de Fractura/efectos adversos , Fijación de Fractura/instrumentación , Fijación de Fractura/métodos , Fijación Interna de Fracturas/instrumentación , Humanos , Complicaciones Posoperatorias
17.
J Colloid Interface Sci ; 501: 231-240, 2017 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-28456107

RESUMEN

Inexpensive and reusable transition metal heterogeneous catalysts exhibiting excellent catalytic performance represent an attractive alternative to noble metal and homogeneous catalysts. In this work, we fabricated a novel nanocatalyst comprised of Co nanoparticles (NPs) supported on a N-doped mesoporous carbon (Co/mCN-900) by simple one-pot pyrolysis of a homogeneous mixture of melamine, polyacrylonitrile, and Co(NO3)2·6H2O under a N2 atmosphere at 900°C. The as-obtained Co/mCN-900 catalyst displayed a fluffy mesoporous structure with highly dispersed and accessible Co NPs acting as catalytic active sites. The Co/mCN-900 catalyst was effective in hydrogenating nitroarenes at milder conditions (i.e., 1MPa H2 and 120°C) as compared to previously reported Co- and Ni-based catalysts. The Co/mCN-900 catalyst also catalyzed the reductive N-alkylation of nitroarenes with carbonyl compounds to form the corresponding aromatic secondary amines under very mild reaction conditions. In addition, the Co/mCN-900 catalyst showed good reusability since its morphology and activity were maintained after several reaction cycles. Therefore, this work provides a facile and promising method for fabricating non-precious transition metal-based catalysts with excellent performance and great potential for sustainable chemistry applications.

18.
J Colloid Interface Sci ; 506: 524-531, 2017 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-28756319

RESUMEN

Novel fluffy smoke like mesoporous N-doped carbon (mNC) was prepared through a facile one-pot carbonization method using the low-cost melamine and polyacrylonitrile as the precursor materials. The obtained mNC material exhibits a high surface area, rich nitrogen content and can be used as an ideal catalyst support to fabricate noble metal modified nanocatalysts. Here, small Ag nanoparticles were supported on the mNC material with high dispersion to give the Ag/mNC nanocatalyst. The obtained Ag/mNC nanocatalyst was used in the catalytic reduction of nitroarenes and showed excellent catalytic activity, probably due to the small Ag NPs which highly dispersed on the fluffy mNC material that can enhance the accessibility and mass transfer, and subsequently enhance the catalytic activity. It is worth mentioning that, in the catalytic reduction of nitroarenes with halogenated groups, almost no dehalogenation phenomenon can be observed, which implies the superior catalytic chemoselectivity of the Ag/mNC nanocatalyst.

19.
Anat Sci Int ; 92(1): 91-97, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26690362

RESUMEN

Precise knowledge of the vascular supply of the femoral head is critical when contemplating surgery around the femoral head and neck junction. To determine the blood supply to the femoral neck, 2417 nutrient foramina from 76 cadaveric specimens were analyzed based on size, number, and distribution. Within the subcapital, transcervical, and basicervical regions of the femoral neck, the largest numbers of nutrient foramina were found on the superior (lateral) surface, followed by the anterior and posterior surfaces, and then the inferior (medial) surface (all p < 0.001). The diameters of most of the nutrient foramina were less than 1 mm. For the posterior and superior surfaces, the nutrient foramina in the basicervical region were significantly larger than those within the transcervical or subcapital regions (nutrient foramina >2 mm posteriorly: 23.6, 12.7, and 9.0 % in the basicervical, transcervical, and subcapital regions, respectively; superiorly: 23.7 vs. 15.4 vs. 16.8 %, respectively). In conclusion, neither the anterior nor the inferior surfaces in the basicervical, transcervical, and subcapital regions showed any significant differences in nutrient foraminal size. The areas containing densely distributed nutrient foramina were consistent with the regions covered by the retinacula of Weitbrecht.


Asunto(s)
Cuello Femoral/anatomía & histología , Cuello Femoral/irrigación sanguínea , Ligamentos Articulares/anatomía & histología , Ligamentos Articulares/irrigación sanguínea , Adulto , Cadáver , Cuello Femoral/diagnóstico por imagen , Humanos , Ligamentos Articulares/diagnóstico por imagen , Membrana Sinovial/anatomía & histología , Membrana Sinovial/irrigación sanguínea , Membrana Sinovial/diagnóstico por imagen , Tomografía Computarizada por Rayos X
20.
Nat Commun ; 7: 11996, 2016 06 29.
Artículo en Inglés | MEDLINE | ID: mdl-27353863

RESUMEN

SARI, also called as BATF2, belongs to the BATF family and has been implicated in cancer cell growth inhibition. However, the role and mechanism of SARI in tumour angiogenesis are elusive. Here we demonstrate that SARI deficiency facilitates AOM/DSS-induced colonic tumorigenesis in mice. We show that SARI is a novel inhibitor of colon tumour growth and angiogenesis in mice. Antibody array and HUVEC-related assays indicate that VEGF has an essential role in SARI-controlled inhibition of angiogenesis. Furthermore, Co-IP/PAGE/mass spectrometry indicates that SARI directly targets ceruloplasmin (Cp), and induces protease degradation of Cp, thereby inhibiting the activity of the HIF-1α/VEGF axis. Tissue microarray results indicate that SARI expression inversely correlates with poor clinical outcomes in colon cancer patients. Collectively, our results indicate that SARI is a potential target for therapy by inhibiting angiogenesis through the reduction of VEGF expression and is a prognostic indicator for patients with colon cancer.


Asunto(s)
Factores de Transcripción con Cremalleras de Leucina de Carácter Básico/metabolismo , Ceruloplasmina/metabolismo , Neoplasias del Colon/metabolismo , Neovascularización Patológica/metabolismo , Proteínas Supresoras de Tumor/metabolismo , Animales , Factores de Transcripción con Cremalleras de Leucina de Carácter Básico/genética , Línea Celular Tumoral , Femenino , Regulación Neoplásica de la Expresión Génica , Humanos , Ratones , Ratones Endogámicos BALB C , Ratones Noqueados , Neoplasias Experimentales/metabolismo , Proteínas Supresoras de Tumor/genética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA