Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Age Ageing ; 48(2): 285-290, 2019 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-30395143

RESUMEN

AIM: to compare the validity of data submitted from a UK level 1 trauma centre to the National Hip Fracture Database (NHFD) before and after the introduction of an electronic health record system (EHRS). PATIENTS AND METHODS: a total of 3224 records were reviewed from July 2009 to July 2017. 2,133 were submitted between July 2009 and October 2014 and 1,091 between October 2014 and July 2017, representing data submitted before and after the introduction of the EHRS, respectively. Data submitted to the NHFD were scrutinised against locally held data. RESULTS: use of an EHRS was associated with significant reductions in NHFD errors. The operation coding error rate fell significantly from 23.2% (494/2133) to 7.6% (83/1091); P < 0.001. Prior to EHRS introduction, of the 109 deaths recorded in the NHFD, 64 (59%) were incorrect. In the EHRS dataset, all the 112 recorded deaths were correct (P < 0.001). There was no significant difference in the error rate for fracture coding. In the EHRS dataset, after controlling for sample month, entries utilising an operation note template with mandatory fields relevant to NHFD data were more likely to be error free than those not using the template (OR 2.69; 95% CI 1.92-3.78). CONCLUSION: this study highlights a potential benefit of EHR systems, which offer automated data collection for auditing purposes. However, errors in data submitted to the NHFD remain, particularly in cases where an NHFD-specific operation note template is not used. Clinician engagement with new technologies is vital to avoid human error and ensure database integrity.


Asunto(s)
Bases de Datos como Asunto , Registros Electrónicos de Salud , Fracturas de Cadera/epidemiología , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/estadística & datos numéricos , Exactitud de los Datos , Bases de Datos como Asunto/organización & administración , Bases de Datos como Asunto/normas , Bases de Datos como Asunto/estadística & datos numéricos , Femenino , Fijación de Fractura/estadística & datos numéricos , Fracturas de Cadera/cirugía , Humanos , Masculino , Persona de Mediana Edad , Centros Traumatológicos/estadística & datos numéricos , Reino Unido/epidemiología
2.
Clin Orthop Relat Res ; 475(1): 273-279, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27586655

RESUMEN

BACKGROUND: Patients sustaining a fractured neck of the femur are typically of advanced age with multiple comorbidities. As a consequence, the proportion of these patients receiving warfarin therapy is approximately 10%. There are currently few studies investigating outcomes in this subset of patients. QUESTIONS/PURPOSES: The purpose of this study was to assess the association between warfarin therapy and time to surgery, length of hospital stay, and survival in patients sustaining a fractured neck of the femur. METHODS: Data for 2036 patients admitted to our center between July 2009 and July 2014 with a fractured neck of the femur were extracted from the National Hip Fracture Database. Fifty-seven patients received no surgical treatment and were excluded from analysis. Multivariable ordinary least squares regression was performed to test the association between warfarin treatment on time to surgery and length of stay, and Cox proportional hazards to test followup survival. Variables included in the regression model were age, sex, American Society of Anesthesiologists (ASA) score, admission Abbreviated Mental Test Score (AMTS), fracture type, operation type, and premorbid Work Ability Index (WAI). One hundred fifty-two of 1979 surgically treated patients (8%) were receiving warfarin therapy at the time of admission. RESULTS: After controlling for age, sex, ASA score, AMTS, fracture type, operation type, and WAI, we found that patients taking warfarin were less likely to go to surgery by 36 hours (odds ratio [OR], 0.20; 95% CI, 0.14-0.30), and less likely to go to surgery by 48 hours (OR, 0.17; 95% CI, 0.11-0.24). Patients taking warfarin had a longer length of stay (median, 15 days; interquartile range [IQR], 12-22 days) compared with patients not taking warfarin (median, 13 days; IQR, 9-20 days; p < 0.001). Survival analysis to June 2015 showed a higher mortality for patients taking warfarin (12-month survival, 66% vs 76%; hazard ratio, 1.57; 95% CI, 1.21-2.04; p < 0.001). CONCLUSIONS: After controlling for multiple prognostic factors such as age, ASA score, AMTS, and WAI, warfarin therapy at the time of injury is associated with increased time to surgery, length of stay, and decreased survival. This study highlights the need to view warfarin therapy as a 'red flag' in patients presenting with a fractured neck of the femur. Preoperatively, prompt warfarin reversal together with adequate investigation and optimization of the patient should ensure timely, safe surgery. Early involvement of the anesthesia team should ensure an appropriate level of postoperative care for these patients. LEVEL OF EVIDENCE: Level III, therapeutic study.


Asunto(s)
Anticoagulantes/uso terapéutico , Fracturas del Cuello Femoral/cirugía , Tiempo de Internación , Warfarina/uso terapéutico , Anciano , Anciano de 80 o más Años , Femenino , Fracturas del Cuello Femoral/mortalidad , Humanos , Masculino , Modelos Teóricos , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia , Factores de Tiempo , Tiempo de Tratamiento , Resultado del Tratamiento
3.
Case Rep Orthop ; 2016: 9127070, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27073707

RESUMEN

A male patient in his fifties presented to his local hospital with numbness and weakness of the right leg which left him unable to mobilise. He reported injecting heroin the previous morning. Following an initial diagnosis of acute limb ischaemia the patient was transferred to a tertiary centre where Computed Tomography Angiography was reported as normal. Detailed neurological examination revealed weakness in hip flexion and extension (1/5 on the Medical Research Council scale) with complete paralysis of muscle groups distal to this. Sensation to pinprick and light touch was globally reduced. Blood tests revealed acute kidney injury with raised creatinine kinase and the patient was treated for rhabdomyolysis. Orthopaedic referral was made the following day and a diagnosis of gluteal compartment syndrome (GCS) was made. Emergency fasciotomy was performed 56 hours after the onset of symptoms. There was immediate neurological improvement following decompression and the patient was rehabilitated with complete nerve recovery and function at eight-week follow-up. This is the first documented case of full functional recovery following a delayed presentation of GCS with sciatic nerve palsy. We discuss the arguments for and against fasciotomy in cases of compartment syndrome with significant delay in presentation or diagnosis.

4.
Injury ; 47(3): 733-6, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26797019

RESUMEN

Pre-operative digital templating allows the surgeon to foresee any anatomical anomalies which may lead to intra-operative problems, and anticipate appropriate instruments and implants required during surgery. Although its role is well-established in successful elective total hip arthroplasty, little work has been done on its use in hip hemiarthroplasty in neck of femur fractures. We describe our initial experience of digital templating in 40 consecutive patients who have undergone cemented hip hemiarthroplasty, assessing templating accuracy between templated implant sizes to actual implant sizes. 81% of implanted heads were templated to within two head sizes, and 89% of implanted stems were templated to within two sizes. Although there was a moderately strong correlation of 0.52 between templated and actual head sizes, this correlation was not demonstrated in femoral stem sizes. Mean leg length discrepancy was -2.5mm (S.D. 8.5), and the mean difference in femoral offset between the operated and non-operated hip was -1mm (S.D. 4.4). Digital templating is a useful adjunct to the surgeon in pre-operative planning of hip hemiarthroplasty in the restoration of leg length and femoral offset. However, its accuracy is inferior to that of elective total hip arthroplasty.


Asunto(s)
Acetábulo/diagnóstico por imagen , Fracturas del Cuello Femoral/diagnóstico por imagen , Hemiartroplastia , Articulación de la Cadera/diagnóstico por imagen , Diferencia de Longitud de las Piernas/cirugía , Cuidados Preoperatorios , Radiografía , Acetábulo/anatomía & histología , Acetábulo/cirugía , Anciano , Anciano de 80 o más Años , Femenino , Fracturas del Cuello Femoral/cirugía , Hemiartroplastia/métodos , Articulación de la Cadera/anatomía & histología , Articulación de la Cadera/cirugía , Prótesis de Cadera , Humanos , Diferencia de Longitud de las Piernas/diagnóstico , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Ajuste de Prótesis , Intensificación de Imagen Radiográfica , Reproducibilidad de los Resultados , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA