Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Vasc Interv Radiol ; 33(9): 1034-1044.e29, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35526675

RESUMEN

PURPOSE: To assess the safety and tolerability of a vandetanib-eluting radiopaque embolic (BTG-002814) for transarterial chemoembolization (TACE) in patients with resectable liver malignancies. MATERIALS AND METHODS: The VEROnA clinical trial was a first-in-human, phase 0, single-arm, window-of-opportunity study. Eligible patients were aged ≥18 years and had resectable hepatocellular carcinoma (HCC) (Child-Pugh A) or metastatic colorectal cancer (mCRC). Patients received 1 mL of BTG-002814 transarterially (containing 100 mg of vandetanib) 7-21 days prior to surgery. The primary objectives were to establish the safety and tolerability of BTG-002814 and determine the concentrations of vandetanib and the N-desmethyl vandetanib metabolite in the plasma and resected liver after treatment. Biomarker studies included circulating proangiogenic factors, perfusion computed tomography, and dynamic contrast-enhanced magnetic resonance imaging. RESULTS: Eight patients were enrolled: 2 with HCC and 6 with mCRC. There was 1 grade 3 adverse event (AE) before surgery and 18 after surgery; 6 AEs were deemed to be related to BTG-002814. Surgical resection was not delayed. Vandetanib was present in the plasma of all patients 12 days after treatment, with a mean maximum concentration of 24.3 ng/mL (standard deviation ± 13.94 ng/mL), and in resected liver tissue up to 32 days after treatment (441-404,000 ng/g). The median percentage of tumor necrosis was 92.5% (range, 5%-100%). There were no significant changes in perfusion imaging parameters after TACE. CONCLUSIONS: BTG-002814 has an acceptable safety profile in patients before surgery. The presence of vandetanib in the tumor specimens up to 32 days after treatment suggests sustained anticancer activity, while the low vandetanib levels in the plasma suggest minimal release into the systemic circulation. Further evaluation of this TACE combination is warranted in dose-finding and efficacy studies.


Asunto(s)
Carcinoma Hepatocelular , Quimioembolización Terapéutica , Neoplasias Hepáticas , Adolescente , Adulto , Carcinoma Hepatocelular/tratamiento farmacológico , Carcinoma Hepatocelular/terapia , Quimioembolización Terapéutica/efectos adversos , Quimioembolización Terapéutica/métodos , Humanos , Neoplasias Hepáticas/tratamiento farmacológico , Neoplasias Hepáticas/terapia , Piperidinas , Inhibidores de Proteínas Quinasas/efectos adversos , Quinazolinas/efectos adversos , Resultado del Tratamiento
2.
Radiology ; 293(3): 695-703, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31617791

RESUMEN

Background Transarterial chemoembolization with cytotoxic drugs is standard treatment for unresectable intermediate-stage hepatocellular carcinoma but achieves suboptimal outcomes because of hypoxic stress and the production of detrimental proangiogenic factors. An alternative approach using radiopaque embolization beads loaded with the antiangiogenic drug vandetanib may provide improved anticancer efficacy. Purpose To evaluate the pharmacokinetics, safety, and efficacy of vandetanib-eluting radiopaque bead (VERB) chemoembolization of rabbit liver tumors. Materials and Methods Between April 2015 and March 2016, 60 New Zealand white rabbits with VX2 liver tumors were randomly treated with VERBs at different doses, with nonloaded radiopaque beads (ROBs), or with intra-arterial vandetanib suspension (VS) or were not treated. Vandetanib plasma concentration and tumor growth at US were evaluated. Animals were euthanized after 3 days or 3 weeks. Assessment included bead distribution at x-ray imaging and histologic examination, tumor viability at histologic examination, and vandetanib tissue concentration. Group comparison analysis (Mann-Whitney, Kruskal-Wallis, and χ2 tests) and predictive factor analysis for tumor growth and viability were performed. Results Vandetanib plasma concentration was lower with VERBs than with VS (P < .01), while concentration in tumor was higher for VERBs (than for VS) at 3 days (median, 29.2 vs 2.74 ng/mg; P = .48). Tumor growth was lower with VERBs than with ROBs and with VS at both time points, with median values of +114%, +192%, and +466% at 3 weeks, respectively. Tumor viability was lower at 3 days for VERBs than for ROBs and for VS (3%, 18%, and 38%, respectively) but was not significantly different at 3 weeks. The volume of bead in tumor was a significant predictive factor for lower tumor growth in multivariable analysis at 3 days (P = .03). Drug tumor concentration was a significant predictive factor for lower tumor growth at 3 weeks (P = .04). Conclusion Vandetanib-eluting radiopaque bead chemoembolization showed a pharmacokinetic advantage over intra-arterial drug administration in a preclinical model of liver cancer. High deposition of beads and high vandetanib concentration in tumor led to stronger antitumor effects. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Kim and Van den Abbeele in this issue.


Asunto(s)
Quimioembolización Terapéutica , Neoplasias Hepáticas Experimentales/diagnóstico por imagen , Neoplasias Hepáticas Experimentales/tratamiento farmacológico , Piperidinas/farmacología , Quinazolinas/farmacología , Animales , Tomografía Computarizada de Haz Cónico , Microesferas , Piperidinas/farmacocinética , Quinazolinas/farmacocinética , Conejos
3.
J Oncol Pharm Pract ; 19(1): 65-74, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22801955

RESUMEN

PURPOSE: Evaluation of doxorubicin stability over time when stored into the DC Bead embolic agent, in various containers, which are used for the delivery of the doxorubicin-loaded beads to the patients for up to 14 days under refrigerated conditions. METHODS: The doxorubicin was loaded through the ionic exchange mechanism into the calibrated polyvinyl alcohol-based hydrogel beads (DC Bead), with the loading process carried out either in the original DC Bead glass vials or within a polypropylene plastic syringe. The loaded samples were eluted at given time points and the extracted doxorubicin was analysed by high-performance liquid chromatography for concentration and chromatographic area response purity. RESULTS: The variance on the doxorubicin concentration of the samples stored in the syringes under refrigerated conditions was less than 10% over the 14 days period. The chromatographic purity of doxorubicin eluted from the DC Bead in their primary glass vial packaging was measured at 99.7%. The dissolution test showed that the elution rate and amount recovered from samples stored in vials were statistically similar between Day 0 and Day 14. The chromatographic purity of the doxorubicin loaded into DC Bead in presence of non-ionic contrast medium was >99.0% for 7 days under refrigerated conditions. CONCLUSIONS: Doxorubicin-loaded DC Bead® are shown to have adequate physicochemical stability over a period of 14 days when stored in syringes or vials under refrigerated conditions for up to 14 days. The admixtures of doxorubicin-loaded beads with contrast medium are stable for up to 7 days under refrigerated conditions.


Asunto(s)
Antibióticos Antineoplásicos/química , Quimioembolización Terapéutica , Doxorrubicina/química , Portadores de Fármacos/química , Embalaje de Medicamentos , Antibióticos Antineoplásicos/administración & dosificación , Antibióticos Antineoplásicos/uso terapéutico , Cromatografía Líquida de Alta Presión , Medios de Contraste/química , Doxorrubicina/administración & dosificación , Doxorrubicina/uso terapéutico , Portadores de Fármacos/administración & dosificación , Portadores de Fármacos/uso terapéutico , Composición de Medicamentos , Estabilidad de Medicamentos , Almacenaje de Medicamentos , Vidrio/química , Yohexol/química , Cinética , Microesferas , Polipropilenos/química , Alcohol Polivinílico/química , Refrigeración , Solubilidad , Espectrofotometría Ultravioleta , Jeringas
4.
J Mater Sci Mater Med ; 24(1): 115-27, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23015264

RESUMEN

Irinotecan eluting embolization beads (DEBIRI) are currently being evaluated in the clinic for the treatment of colorectal cancer metastases to the liver. The aim of this study was to determine the safety and pharmacokinetics associated with two cycles of hepatic embolization using DEBIRI followed by intravenous administration of irinotecan. Pigs were embolized with DEBIRI (100-300 µm, 100 mg dose, n = 6) and blood samples taken over 24 h to determine plasma levels of irinotecan and SN-38 metabolite and for haematology and biochemistry. At 24 h an IV infusion of 250 mg/m(2) of irinotecan was administered and the plasma levels taken again. This cycle was repeated 3 weeks later. A single animal was subjected to a more aggressive regimen of embolization with 200 mg bead dose and IV of 350 mg/m(2) for two cycles. Three animals were sacrificed at 6 weeks and the remaining four (n = 3 standard dose, n = 1 high dose) animals at 12 weeks and detailed histopathology performed. All animals tolerated the treatments well, with only minor changes in haematological and biochemical parameters. There was no overlap in drug plasma levels observed from the bead and IV treatments when given 24 h apart and no difference between the pharmacokinetic profiles of the two cycles separated by 3 weeks. Irinotecan plasma AUC values were similar in both the embolization and IV arms of the study. C(max) values obtained during the IV arms of the study are approximately double that of the embolization arms whilst T(max) times are shorter in the IV arms, supporting extended release of drug from the beads. Bioavailability for bead-based delivery was double that for IV administration, which was attributed to reduced clearance of the drug when delivered by this route. No additive toxicity was observed as a consequence of the combined treatments. The combination of irinotecan delivery via drug eluting bead and IV was well-tolerated with no significant clinical effects. Pharmacokinetic analyses suggest the bioavailability from bead-based delivery of drug is double that of IV infusion, attributable to reduced drug clearance for the former.


Asunto(s)
Antineoplásicos Fitogénicos/administración & dosificación , Camptotecina/análogos & derivados , Hígado/metabolismo , Modelos Animales , Administración Intravenosa , Animales , Antineoplásicos Fitogénicos/sangre , Antineoplásicos Fitogénicos/farmacocinética , Camptotecina/administración & dosificación , Camptotecina/sangre , Camptotecina/farmacocinética , Estudios de Factibilidad , Irinotecán , Porcinos
5.
Eur J Pharm Sci ; 136: 104943, 2019 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-31152772

RESUMEN

Drug-eluting Embolic Bead - Transarterial Chemoembolisation (DEB-TACE) is a minimally invasive embolising treatment for liver tumours that allows local release of chemotherapeutic drugs via ion exchange, following delivery into hepatic arterial vasculature. Thus far, no single in vitro model has been able to accurately predict the complete kinetics of drug release from DEB, due to heterogeneity of rate-controlling mechanisms throughout the process of DEB delivery. In this study, we describe two in vitro models capable of distinguishing between early phase and late phase drug release by mimicking in vivo features of each phase. First, a vascular flow system (VFS) was used to simulate the early phase by delivering DEB into a silicon vascular cast under high pulsatile flow. This yielded a burst release profile of drugs from DEB which related to the dose adjusted Cmax observed in pharmacokinetic plasma profiles from a preclinical swine model. Second, an open loop flow-through cell system was used to model late phase drug release by packing beads in a column with an ultra-low flow rate. DEB loaded with doxorubicin, irinotecan and vandetanib showed differential drug release rates due to their varying chemical properties and unique drug-bead interactions. Using more representative in vitro models to map discrete phases of DEB drug release will provide a better capability to predict the pharmacokinetics of developmental formulations, which has implications for treatment safety and efficacy.


Asunto(s)
Doxorrubicina/farmacocinética , Liberación de Fármacos/fisiología , Irinotecán/farmacocinética , Piperidinas/farmacocinética , Quinazolinas/farmacocinética , Animales , Quimioembolización Terapéutica/métodos , Sistemas de Liberación de Medicamentos/métodos , Técnicas In Vitro , Hígado/efectos de los fármacos , Hígado/metabolismo , Neoplasias Hepáticas/tratamiento farmacológico , Neoplasias Hepáticas/metabolismo , Porcinos
6.
JMIR Res Protoc ; 8(10): e13696, 2019 Oct 02.
Artículo en Inglés | MEDLINE | ID: mdl-31579027

RESUMEN

BACKGROUND: Transarterial chemoembolization (TACE) is the current standard of care for patients with intermediate-stage hepatocellular carcinoma (HCC) and is also a treatment option for patients with liver metastases from colorectal cancer. However, TACE is not a curative treatment, and tumor progression occurs in more than half of the patients treated. Despite advances and technical refinements of TACE, including the introduction of drug-eluting beads-TACE, the clinical efficacy of TACE has not been optimized, and improved arterial therapies are required. OBJECTIVE: The primary objectives of the VEROnA study are to evaluate the safety and tolerability of vandetanib-eluting radiopaque embolic beads (BTG-002814) in patients with resectable liver malignancies and to determine concentrations of vandetanib and the N-desmethyl metabolite in plasma and resected liver following treatment with BTG-002814. METHODS: The VEROnA study is a first-in-human, open-label, single-arm, phase 0, window-of-opportunity study of BTG-002814 (containing 100 mg vandetanib) delivered transarterially, 7 to 21 days before surgery in patients with resectable liver malignancies. Eligible patients have a diagnosis of colorectal liver metastases, or HCC (Childs Pugh A), diagnosed histologically or radiologically, and are candidates for liver surgery. All patients are followed up for 28 days following surgery. Secondary objectives of this study are to evaluate the anatomical distribution of BTG-002814 on noncontrast-enhanced imaging, to evaluate histopathological features in the surgical specimen, and to assess changes in blood flow on dynamic contrast-enhanced magnetic resonance imaging following treatment with BTG-002814. Exploratory objectives of this study are to study blood biomarkers with the potential to identify patients likely to respond to treatment and to correlate the distribution of BTG-002814 on imaging with pathology by 3-dimensional modeling. RESULTS: Enrollment for the study was completed in February 2019. Results of a planned interim analysis were reviewed by a safety committee after the first 3 patients completed follow-up. The recommendation of the committee was to continue the study without any changes to the dose or trial design, as there were no significant unexpected toxicities related to BTG-002814. CONCLUSIONS: The VEROnA study is studying the feasibility of administering BTG-002814 to optimize the use of this novel technology as liver-directed therapy for patients with primary and secondary liver cancer. TRIAL REGISTRATION: ClinicalTrial.gov NCT03291379; https://clinicaltrials.gov/ct2/show/NCT03291379. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/13696.

7.
Theranostics ; 7(8): 2164-2176, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28740542

RESUMEN

PURPOSE: To evaluate the plasma and tissue pharmacokinetics, safety and toxicity following intra-arterial hepatic artery administration of Vandetanib (VTB)-eluting Radiopaque Beads (VERB) in healthy swine. MATERIALS AND METHODS: In a first phase, healthy swine were treated with hepatic intra-arterial administration of VERB at target dose loading strengths of 36 mg/mL (VERB36), 72 mg/mL (VERB72) and 120 mg/mL (VERB120). Blood and tissue samples were taken and analysed for VTB and metabolites to determine pharmacokinetic parameters for the different dose forms over 30 days. In a second phase, animals were treated with unloaded radiopaque beads or high dose VTB loaded beads (VERB100, 100 mg/mL). Tissue samples from embolized and non-embolized areas of the liver were evaluated at necropsy (30 and 90 days) for determination of VTB and metabolite levels and tissue pathology. Imaging was performed prior to sacrifice using multi-detector computed tomography (MDCT) and imaging findings correlated with pathological changes in the tissue and location of the radiopaque beads. RESULTS: The peak plasma levels of VTB (Cmax) released from the various doses of VERB ranged between 6.19-17.3 ng/mL indicating a low systemic burst release. The plasma profile of VTB was consistent with a distribution phase up to 6 h after administration followed by elimination with a half-life of 20-23 h. The AUC of VTB and its major metabolite N-desmethyl vandetanib (NDM VTB) was approximately linear with the dose strength of VERB. VTB plasma levels were at or below limits of detection two weeks after administration. In liver samples, VTB and NDM VTB were present in treated sections at 30 days after administration at levels above the in vitro IC50 for biological effectiveness. At 90 days both analytes were still present in treated liver but were near or below the limit of quantification in untreated liver sections, demonstrating sustained release from the VERB. Comparison of the reduction of the liver lobe size and associated tissue changes suggested a more effective embolization with VERB compared to the beads without drug. CONCLUSIONS: Hepatic intra-arterial administration of VERB results in a low systemic exposure and enables sustained delivery of VTB to target tissues following embolization. Changes in the liver tissue are consistent with an effective embolization and this study has demonstrated that VERB100 is well tolerated with no obvious systemic toxicity.


Asunto(s)
Medios de Contraste/efectos adversos , Medios de Contraste/farmacocinética , Embolización Terapéutica/métodos , Hígado/patología , Piperidinas/efectos adversos , Piperidinas/farmacocinética , Quinazolinas/efectos adversos , Quinazolinas/farmacocinética , Animales , Medios de Contraste/administración & dosificación , Inyecciones Intraarteriales , Hígado/diagnóstico por imagen , Modelos Animales , Piperidinas/administración & dosificación , Quinazolinas/administración & dosificación , Radiografía Abdominal , Porcinos , Tomografía Computarizada por Rayos X
8.
Eur J Pharm Sci ; 101: 22-30, 2017 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-28132823

RESUMEN

Since their introduction around a decade ago, embolic drug-eluting beads (DEBs) have become a well-established treatment option for the locoregional transarterial treatment of hepatic malignancies. Despite this success, the therapy is seen to be limited by the choice of drug and more effective options are therefore being sought. These include the small molecule multi-tyrosine kinase inhibitors (MTKi), which exert an anti-angiogenic and anti-proliferative effect that could be highly beneficial in combating some of the unwanted downstream consequences of embolization. Vandetanib is an MTKi which acts against such targets as vascular endothelial growth factor receptor (VEGFR) and epithelial growth factor receptor (EGFR) and has demonstrated modest activity against hepatocellular carcinoma (HCC), albeit with some dose-limiting cardiac toxicity. This makes this compound an interesting candidate for DEB-based locoregional delivery. In this study we describe the preparation and characterisation of vandetanib DEBs made from DC Bead™ and its radiopaque counterpart, DC Bead LUMI™. Drug loading was shown to be dependent upon the pH of the drug loading solution, as vandetanib has multiple sites for protonation, with the bead platform also having a fundamental influence due to differences in binding capacities and bead shrinkage effects. Fourier transform infrared (FTIR) spectroscopy and energy dispersive X-ray (EDX) Spectroscopy confirmed drug interaction is by ionic interaction, and in the case of the radiopaque DEB, the drug is distributed uniformly inside the bead and contributes slightly to the overall radiopacity by virtue of a bromine atom on the vandetanib structure. Drug release from both bead platforms is controlled and sustained, with a slightly slower rate of release from the radiopaque bead due to its more hydrophobic nature. Vandetanib DEBs therefore have suitable characteristics for intra-arterial delivery and site-specific sustained release of drug into liver tumours.


Asunto(s)
Medios de Contraste/química , Neoplasias Hepáticas/tratamiento farmacológico , Piperidinas/química , Piperidinas/farmacología , Quinazolinas/química , Quinazolinas/farmacología , Carcinoma Hepatocelular/tratamiento farmacológico , Carcinoma Hepatocelular/metabolismo , Portadores de Fármacos/química , Receptores ErbB/metabolismo , Humanos , Neoplasias Hepáticas/metabolismo , Microesferas , Factor A de Crecimiento Endotelial Vascular/metabolismo
9.
J Control Release ; 127(1): 70-8, 2008 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-18237814

RESUMEN

The distribution of the active lactone and the inactive carboxylate forms of irinotecan released from drug eluting beads composed of a sulfonate-modified PVA hydrogel was studied in order to ascertain the interaction between irinotecan, a water-soluble derivative of anti-cancer drug camptothecin, and the sulfonate groups in beads. Under a neutral condition of pH 7.0, it was demonstrated that the lactone form preferentially binds with sulfonate groups in the hydrogel beads through charge-charge interaction, and the equilibrium of the two forms shifts in favour of the lactone. In terms of stability, the drug-sulfonate interaction results in the retention of the active lactone form within the hydrogel beads. Kinetic experiments indicated that in PBS, the rate constants of lactone hydrolysis and carboxylate lactonization were 3.10 (+/-0.33)x10(-3) min(-1) and 1.36 (+/-0.04)x10(-3) min(-1), respectively. The modelling and elution experiments of the distribution of the lactone and carboxylate during irinotecan delivery by different methods, such as bolus injection, infusion and bead delivery, showed that both infusion and embolic bead delivery provided the lactone form with prolonged half-life. In addition, drug eluting beads have the characteristics of targeted delivery and low toxicity and the advantage of storage of the active form of irinotecan by polyanion stabilisation for use in local therapy of metastatic colorectal cancer to the liver.


Asunto(s)
Antineoplásicos Fitogénicos , Camptotecina/análogos & derivados , Neoplasias Colorrectales/patología , Sistemas de Liberación de Medicamentos/métodos , Lactonas/química , Neoplasias Hepáticas , Antineoplásicos Fitogénicos/administración & dosificación , Antineoplásicos Fitogénicos/química , Antineoplásicos Fitogénicos/uso terapéutico , Camptotecina/administración & dosificación , Camptotecina/química , Camptotecina/uso terapéutico , Estabilidad de Medicamentos , Humanos , Hidrogeles/química , Concentración de Iones de Hidrógeno , Irinotecán , Cinética , Neoplasias Hepáticas/tratamiento farmacológico , Neoplasias Hepáticas/secundario , Microesferas , Modelos Químicos , Tamaño de la Partícula , Solubilidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA