Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Foot Ankle Surg ; 21(1): e27-31, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25682419

RESUMEN

We present a rare injury consisting of a neglected, irreducible, dislocation of the first metatarsophalangeal joint that was diagnosed 4 months after the injury. An open reduction was necessary from the beginning. Patient returned to full activity without pain or disability, so a good prognosis despite the delayed diagnosis was achieved. We are unaware of previous reports in the literature describing this unusual variant.


Asunto(s)
Luxaciones Articulares/cirugía , Articulación Metatarsofalángica/cirugía , Anciano , Humanos , Luxaciones Articulares/diagnóstico por imagen , Masculino , Articulación Metatarsofalángica/lesiones , Radiografía
2.
Acta Orthop Belg ; 73(1): 60-9, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17441660

RESUMEN

The Locking Compression Plate (LCP) and the Less Invasive Stabilisation System (LISS) are new implants with angular stability developed by the AO/ASIF. They offer an alternative for internal fixation in complex intra-articular fractures and high-energy diaphyseal fractures of the long bones. The new system was used in a prospective study to treat 113 patients (76 women, 37 men; average age: 53.1 years) with 122 injuries (multifragment shaft fractures or complex intra-articular, delayed/ non-union, malunion) from October 2002. Of these, 13 affected the humerus, 20 the radius, 2 the ulna, 21 the femur, 42 the tibia, 10 the fibula, 2 the acetabulum and 12 the calcaneus. Because of severe concomitant injuries, 18 fractures were first treated with an external fixator and definitively stabilised more than two weeks after the injury. Thirty-one patients were operated on after failure of other implants and non-union. Clinical and radiographic findings as well as complications were followed prospectively over a mean period of 20 months (range: 13 to 30). One patient was lost to follow-up. A total of 112 patients underwent a standardised follow-up examination. The outcome correlated with the severity of the fracture, anatomic reduction, adequate positioning of the plate and concomitant injuries. Despite the large number of open and comminuted fractures, no serious complications such as deep infections, vascular lesions, deep venous thrombosis or non-unions were noted. We found the new internal fixator system to be a safe and reliable procedure. It offers numerous fixation possibilities and has proven its value in complex fracture situations and in revision operations. A good knowledge of biomechanics is essential as well as precise preoperative planning.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas/instrumentación , Fracturas Óseas/cirugía , Fijadores Internos , Acetábulo/lesiones , Adulto , Anciano , Anciano de 80 o más Años , Calcáneo/lesiones , Diáfisis/lesiones , Femenino , Fracturas del Fémur/cirugía , Peroné/lesiones , Estudios de Seguimiento , Fracturas Conminutas/cirugía , Fracturas Mal Unidas/cirugía , Fracturas Abiertas/cirugía , Fracturas no Consolidadas/cirugía , Humanos , Fracturas del Húmero/cirugía , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Fracturas del Radio/cirugía , Reoperación , Fracturas de la Tibia/cirugía , Resultado del Tratamiento , Fracturas del Cúbito/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA