Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Echocardiography ; 37(9): 1374-1381, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32815581

RESUMEN

AIM: Doppler echocardiography has become the standard imaging modality for diastolic function and provides pathophysiological insight into systolic and diastolic heart failure. In this study, we aimed to obtain normal echocardiographic Doppler parameters of healthy Turkish population. METHODS: Among 31 collaborating institutions from all regions of Turkey, 1154 healthy volunteers were enrolled in this study. Predefined protocols were used for all participants during echocardiographic examination and The American Society of Echocardiography and European Association of Cardiovascular Imaging recommendations were used for echocardiographic Doppler measurements. RESULTS: A total of 967 healthy participants were enrolled in this study after applying exclusion criteria. Echocardiographic examination was obtained from all subjects following predefined protocols. Mitral E wave velocity and E/A ratio were higher in females and decreased progressively in advancing ages. E wave deceleration time and A wave velocity were increased with aging. Assessment of tissue Doppler velocities showed that left ventricular lateral e', septal e', and septal s' were higher in younger subjects and in females. E/e' ratio was increased progressively with advancing decades. Right ventricular e' and s' were decreased but a' was increased with increasing age. Septal e' lower than 8 cm/s was 1.9% in the fifth decade and 13.7% in ages older than 50 years. The E/e' ratio greater than 15 (and also 13) was not found. CONCLUSION: This study, for the first time, provides echocardiographic reference ranges for normal cardiac Doppler data in healthy Turkish population which will be useful in routine clinical practice as well as in future clinical trials.


Asunto(s)
Ecocardiografía , Anciano , Anciano de 80 o más Años , Diástole , Femenino , Humanos , Persona de Mediana Edad , Valores de Referencia , Sístole , Turquía
2.
Ann Noninvasive Electrocardiol ; 21(4): 352-7, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26392007

RESUMEN

BACKGROUND: Early diagnosis and identification of high-risk non-ST elevation myocardial infarction (NSTEMI) is an important issue. Fragmented QRS (fQRS) complexes are defined as various RSR' patterns on 12-lead resting electrocardiography (ECG). Previous studies revealed that fQRS is related with increased ventricular arrhythmias and cardiovascular mortality. The relation between fQRS and mortality in acute coronary syndromes, mitral valve disease severity and structural heart disease has been shown in different studies. The aim of this study was to investigate relation between fQRS and long-term cardiovascular mortality in NSTEMI patients. METHODS: Patients who admitted to our emergency unit and diagnosed NSTEMI between 2012 and 2013, 433 patients were included prospectively. fQRS complexes determined in 85 patients. Patients were divided into two groups according to fQRS existence. All patients evaluated for their clinical, laboratory, electrocardiographic, and echocardiographic characteristics. Angiographic features of 315 patients who underwent coronary angiography was also recorded. In-hospital, 30-day and 12-month mortality was compared between these groups. RESULTS: Demographic characteristics and cardiovascular risk factors were similar in both groups except hyperlipidemia. GRACE risk score was higher in patients with fQRS and positively correlated with existence of fQRS. In hospital and 30-days mortality were similar but late mortality was higher in fQRS group. Predictors of late mortality were found to be age, heart rate, male sex in addition to fQRS. CONCLUSION: We found a relation between fQRS and late mortality. Fragmented QRS may be seen as a cautionary signal for extensive myocardial damage and thereby increased long-term mortality for patients with NSTEMI.


Asunto(s)
Electrocardiografía , Infarto del Miocardio sin Elevación del ST/mortalidad , Infarto del Miocardio sin Elevación del ST/fisiopatología , Angiografía Coronaria , Ecocardiografía , Servicio de Urgencia en Hospital , Femenino , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo
3.
Echocardiography ; 31(10): 1293-309, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25257956

RESUMEN

Currently, tricuspid valve infective endocarditis (TVIE) is encountered in daily clinical practice more frequently due to the increasing prevalence of illicit intravenous drug use and the implantation of intracardiac devices. In this study, we compared findings from intra-operative live/real time three-dimensional transesophageal echocardiograms (3DTEE) and two-dimensional transesophageal echocardiograms (2DTEE) of 10 patients who underwent surgery for native tricuspid valve (TV) endocarditis. Unlike 2DTEE, 3DTEE allowed en face visualization of the 3 TV leaflets from both, atrial and ventricular aspects, in 9 of the 10 cases. In the remaining patient, in whom 3DTEE could not identify all 3 leaflets en face, the TV was found essentially destroyed at surgery. Using 3DTEE, the number of vegetations was accurately reported when compared with the surgical record. Furthermore, the orientation of each vegetation was the same as noted in the surgical findings. 2DTEE missed the identification of vegetations in 5 patients. The attachment site of vegetations to the TV were also not characterized by 2DTEE in 5 patients. In all 10 cases, 3DTEE characterized the vegetations more accurately with larger dimensions, including those in the azimuthal axis, and volumes. In addition, a perivalvular abscess that lead to surgical intervention was identified by 3DTEE, however, missed by 2DTEE. In conclusion, 3DTEE allows en face visualization of the TV apparatus permitting accurate description of the number and dimensions of vegetations identified by our surgical standard, which ultimately informs patients' prognosis and dictates the timing and planning for surgical intervention. Its use should be in conjunction with 2DTEE when evaluating TVIE.


Asunto(s)
Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica , Endocarditis/diagnóstico por imagen , Válvula Tricúspide/diagnóstico por imagen , Adulto , Procedimientos Quirúrgicos Cardíacos/métodos , Estudios de Cohortes , Endocarditis/microbiología , Endocarditis/cirugía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Estudios Retrospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Válvula Tricúspide/microbiología , Válvula Tricúspide/cirugía
4.
Am J Emerg Med ; 31(5): 891.e1-3, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23602755

RESUMEN

The patients with ST-elevation myocardial infarction are primarily managed with percutaneous coronary intervention (PCI) or thrombolysis. It is well accepted that rescue PCI should be implemented in case of unsuccessful thrombolysis. However, the reverse, rescue thrombolysis, that is, administering of thrombolytic therapy in a patient in whom primary PCI fails, is not well defined. There are no available data about rescue thrombolysis so far. We represent a 43-year-old male patient with Buerger disease (thromboangiitis obliterans) who was admitted to our emergency department for cardiac shock related to inferior and right ventricular ST-elevation myocardial infarction. He was found to have occlusion of both right coronary artery and left anterior descending artery and managed with rescue thrombolysis. It was subsequently recognized that he had concurrent stroke caused by posterior cerebral artery (PCA) occlusion and improved with thrombolysis. It is reported for the first time that rescue thrombolysis has been put into practice and yielded great result after unsuccessful primary PCI.


Asunto(s)
Fibrinolíticos/uso terapéutico , Infarto de la Arteria Cerebral Posterior/tratamiento farmacológico , Terapia Recuperativa , Choque Cardiogénico/tratamiento farmacológico , Activador de Tejido Plasminógeno/uso terapéutico , Adulto , Humanos , Infarto de la Arteria Cerebral Posterior/complicaciones , Infarto de la Arteria Cerebral Posterior/diagnóstico , Infarto de la Arteria Cerebral Posterior/cirugía , Masculino , Intervención Coronaria Percutánea , Choque Cardiogénico/complicaciones , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/cirugía
5.
Acta Cardiol ; 68(5): 464-8, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24283106

RESUMEN

BACKGROUND: Nitric oxide (NO) plays a major role in the regulation of endothelial functions and reduced NO synthesis has been implicated in the development of coronary atherosclerosis. Endothelial nitric oxide synthase (eNOS) intron 4a/b polymorphism has been shown to be related to plasma nitric oxide concentrations and coronary artery disease in various population studies. The aim of this study is to assess the relationship between eNOS 4a/b polymorphism and premature CAD. MATERIAL AND METHODS: A total of 70 patients under age 35 who presented with ST-segment elevation myocardial infarction (STEMI) were included in this study.The control group included 50 age- and gender-matched subjects with normal coronary arteries on angiography.The eNOS 4a/b polymorphism was assessed with polymerase chain reaction (PCR).The frequencies of eNOS 4a/b genotypes and alleles were compared. Multivariate regression analysis was used for estimation of the independent predictors of premature CAD. RESULTS: Frequency of eNOS4a/b gene, aa and ab genotypes were significantly higher in STEMI patients when compared to control group. Presence of allele'a'of the eNOS gene was an independent predictor of STEMI in a young population (OR: 2.78 95% CI: 1.02-7.56 P = 0.044). A significant correlation of eNOS gene polymorphism with other clinical properties of subjects was not established. CONCLUSION: The eNOS4a/b gene polymorphism may be associated with early development of atherosclerosis and myocardial infarction possibly secondary to deterioration of the endothelial function.


Asunto(s)
Enfermedad de la Arteria Coronaria/genética , ADN/genética , Endotelio Vascular/fisiopatología , Predisposición Genética a la Enfermedad , Óxido Nítrico Sintasa de Tipo III/genética , Polimorfismo Genético , Vasodilatación/genética , Adulto , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/enzimología , Electrocardiografía , Endotelio Vascular/metabolismo , Femenino , Estudios de Seguimiento , Frecuencia de los Genes , Genotipo , Humanos , Masculino , Infarto del Miocardio/enzimología , Infarto del Miocardio/etiología , Infarto del Miocardio/genética , Óxido Nítrico/sangre , Óxido Nítrico Sintasa de Tipo III/sangre , Reacción en Cadena de la Polimerasa , Pronóstico , Estudios Prospectivos
6.
Echocardiography ; 29(3): E72-7, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22432650

RESUMEN

We present an adult with metastatic carcinoid disease affecting the heart, in whom live/real time three-dimensional transthoracic echocardiography (3DTTE) provided incremental value over two-dimensional transthoracic echocardiography (2DTTE). Initial 2DTTE was able to demonstrate severe pulmonic and tricuspid regurgitation, but was unable to visualize the posterior leaflet of the tricuspid valve or the right (right anterior) leaflet of the pulmonic valve. Further analysis with 3DTTE demonstrated thickening, restricted mobility, and noncoaptation of all three leaflets of both the tricuspid and the pulmonary valves. En face viewing of tricuspid and pulmonary regurgitation vena contractas permitted more reliable quantification of regurgitation severity. In addition, localized, linear, echogenic areas consistent with carcinoid deposits were noted along the inner walls of the right atrium, atrial septum, and inferior vena cava. To the best of our knowledge, endocardial carcinoid deposits have never been reported by 2D or 3D echocardiography. En face viewing of these deposits by 3DTTE enabled measurement of their dimensions and areas. Subcostal examination also identified large circumscribed hepatic lesions consistent with metastatic disease. Neither the carcinoid deposits nor the metastatic lesions were detected by 2DTTE. This case demonstrates the usefulness of 3DTTE as a supplement to 2DTTE in more comprehensively assessing carcinoid involvement of the heart.


Asunto(s)
Cardiopatía Carcinoide/complicaciones , Cardiopatía Carcinoide/diagnóstico por imagen , Ecocardiografía Tridimensional/métodos , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/etiología , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/etiología , Sistemas de Computación , Femenino , Humanos , Persona de Mediana Edad
7.
Echocardiography ; 29(6): 751­756, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22962695

RESUMEN

We present an adult with metastatic carcinoid disease affecting the heart, in whom live/real time three-dimensional transthoracic echocardiography (3DTTE) provided incremental value over two-dimensional transthoracic echocardiography (2DTTE). Initial 2DTTE was able to demonstrate severe pulmonic and tricuspid regurgitation, but was unable to visualize the posterior leaflet of the tricuspid valve or the right (right anterior) leaflet of the pulmonic valve. Further analysis with 3DTTE demonstrated thickening, restricted mobility, and noncoaptation of all three leaflets of both the tricuspid and the pulmonary valves. En face viewing of tricuspid and pulmonary regurgitation vena contractas permitted more reliable quantification of regurgitation severity. In addition, localized, linear, echogenic areas consistent with carcinoid deposits were noted along the inner walls of the right atrium, atrial septum, and inferior vena cava. To the best of our knowledge, endocardial carcinoid deposits have never been reported by 2D or 3D echocardiography. En face viewing of these deposits by 3DTTE enabled measurement of their dimensions and areas. Subcostal examination also identified large circumscribed hepatic lesions consistent with metastatic disease. Neither the carcinoid deposits nor the metastatic lesions were detected by 2DTTE. This case demonstrates the usefulness of 3DTTE as a supplement to 2DTTE in more comprehensively assessing carcinoid involvement of the heart.


Asunto(s)
Cardiopatía Carcinoide/complicaciones , Cardiopatía Carcinoide/diagnóstico por imagen , Ecocardiografía Tridimensional/métodos , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/etiología , Válvulas Cardíacas/diagnóstico por imagen , Sistemas de Computación , Femenino , Humanos , Persona de Mediana Edad
8.
Echocardiography ; 29(9): 1128-31, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22931539

RESUMEN

Percutaneous closure of secundum atrial defects has become an accepted treatment in part because it is minimally invasive and relatively low risk. Despite recent advances in implantation technique and device improvements, complications occur. Here, we report a case of device embolization during percutaneous repair of an atrial septal defect (ASD) with multiple fenestrations. We highlight the value of using live/real time three-dimensional transesophageal echocardiography to help plan the percutaneous procedure and detect complications.


Asunto(s)
Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/métodos , Embolización Terapéutica/instrumentación , Defectos del Tabique Interatrial/diagnóstico por imagen , Defectos del Tabique Interatrial/cirugía , Arteria Ilíaca/cirugía , Cirugía Asistida por Computador/métodos , Humanos , Masculino , Dispositivo Oclusor Septal , Resultado del Tratamiento
9.
Echocardiography ; 29(5): 620-30, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22537236

RESUMEN

We compared findings from intraoperative live/real time three-dimensional transesophageal echocardiography (3DTEE) and two-dimensional transesophageal echocardiography (2DTEE) with surgery in 67 patients having aortic aneurysm and/or aortic dissection. Of these, 20 patients had aortic aneurysm without dissection, 21 aortic aneurysm and dissection, and 26 aortic dissection without aneurysm. 3DTEE diagnosed the type and location of aneurysm correctly in all patients unlike 2DTEE, which missed an aneurysm in one case. There were four cases of aortic aneurysm rupture. Three of them were diagnosed by 3DTEE but only one by 2DTEE, and one missed by both techniques. The mouth of saccular aneurysm, site of aortic aneurysm rupture, and communication sites between perfusing and nonperfusing lumens of aortic dissection could be viewed en face only with 3DTEE, enabling comprehensive measurements of their area and dimensions as well as increasing the confidence level of their diagnosis. In all patients with aortic dissection, 3DTEE enabled a more confident diagnosis of dissection because the dissection flap when viewed en face presented as a sheet of tissue rather than a linear echo seen on 2DTEE which can be confused with an artifact. 2DTEE missed dissection in one patient. In six cases the dissection flap involved the right coronary artery orifice by 3DTEE and surgery. These were missed by 2DTEE. Aortic regurgitation severity was more comprehensively assessed by 3DTEE than 2DTEE. Aneurysm size by 3DTEE correlated well with 2DTEE and surgery/computed tomography scan. In conclusion, 3DTEE provides incremental information over 2DTEE in patients with aortic aneurysm and dissection.


Asunto(s)
Aneurisma de la Aorta/diagnóstico por imagen , Disección Aórtica/diagnóstico por imagen , Ecocardiografía Tridimensional/métodos , Ecocardiografía/métodos , Adulto , Anciano , Anciano de 80 o más Años , Sistemas de Computación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
10.
Acta Cardiol ; 66(2): 267-9, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21591591

RESUMEN

Myotonic dystrophy type 1 (DM1) is the most frequent muscular dystrophy in adults. It is a multisystem disorder also affecting the heart with an increased incidence of sudden cardiac death. We present a young female patient with ventricular tachycardia (VT) who had no cardiac complaints previously. In this patient, the phenotypic characteristics implying DM1, neuromuscular testing and genetic analysis all confirmed the diagnosis of DM1 and because of the malignant nature of VT, she received an implantable cardioverter/defibrillator.


Asunto(s)
Distrofia Miotónica/complicaciones , Taquicardia Ventricular/complicaciones , Desfibriladores Implantables , Diagnóstico Diferencial , Ecocardiografía , Electrocardiografía , Femenino , Humanos , Distrofia Miotónica/diagnóstico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Adulto Joven
11.
Turk Gogus Kalp Damar Cerrahisi Derg ; 26(1): 14-21, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32082706

RESUMEN

BACKGROUND: In this study, we aimed to present our results of mitral valve repair. METHODS: Between January 2007 and November 2016, a total of 128 patients (72 males, 56 females; mean age 51.8±17.2 years; range 16 to 84 years) who underwent mitral valve repair in our heart center were retrospectively analyzed. There were mitral regurgitation in 86.7% (n=111), mitral stenosis in 7.8% (n=10), and mixed type valve disease in 5.5% of the patients (n=7). Mitral ring annuloplasty was performed in 80.5% (n=103), implantation of the artificial chordae in 36.7% (n=47), open mitral commissurotomy in 13.3% (n=17), and Alfieri procedure in 6.3% (n=8) of the patients. Sixty-two patients (48.8%) underwent isolated mitral valve repair, while concomitant surgical procedures were performed in the remaining patients. Postoperative mean follow-up was 52 months. RESULTS: Early (30-day) mortality was observed in seven patients due to low cardiac output. There was no mid-term mortality. During follow-up, various degree of mitral regurgitation was detected in 4 patients (3.6%), regurgitation was severe in two of them and these two require reoperation with the replacement of the valve. Patients with a myxomatous valve pathology who underwent isolated valve repair most benefited from valve repair. Patients with isolated mitral stenosis were the most successful group among the patients with a rheumatic etiology. Postoperative echocardiography showed a significant decrease in the left atrial diameter and pulmonary artery systolic pressures (p<0.01). CONCLUSION: Mitral valve repair can be applied as an effective and safe treatment method in patients in whom the mitral valve anatomy is sufficient for repair. We suggest that each patient with mitral valve pathology should be evaluated in terms of reparability.

12.
Int J Cardiovasc Imaging ; 33(9): 1323-1330, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28285328

RESUMEN

In a fraction of patients with mild mitral stenosis, left ventricular systolic function deteriorates despite the lack of hemodynamic load imposed by the dysfunctioning valve. Neither the predisposing factors nor the earlier changes in left ventricular contractility were understood adequately. In the present study we aimed to evaluate left ventricular mechanics using three-dimensional (3D) speckle tracking echocardiography. A total of 31 patients with mild rheumatic mitral stenosis and 27 healthy controls were enrolled to the study. All subjects included to the study underwent echocardiographic examination to collect data for two- and three-dimensional speckle-tracking based stain, twist angle and torsion measurements. Data was analyzed offline with a echocardiographic data analysis software. Patients with rheumatic mild MS had lower global longitudinal (p < 0.001) circumferential (p = 0.02) and radial (p < 0.01) strain compared to controls, despite ejection fraction was similar for both groups [(p = 0.45) for three dimensional and (p = 0.37) for two dimensional measurement]. While the twist angle was not significantly different between groups (p = 0.11), left ventricular torsion was significantly higher in mitral stenosis group (p = 0.03). All strain values had a weak but significant positive correlation with mitral valve area measured with planimetry. Subclinical left ventricular systolic dysfunction develops at an early stage in rheumatic mitral stenosis. Further work is needed to elucidate patients at risk for developing overt systolic dysfunction.


Asunto(s)
Ecocardiografía Doppler/métodos , Ecocardiografía Tridimensional/métodos , Estenosis de la Válvula Mitral/diagnóstico por imagen , Contracción Miocárdica , Cardiopatía Reumática/diagnóstico por imagen , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda , Adulto , Enfermedades Asintomáticas , Fenómenos Biomecánicos , Estudios de Casos y Controles , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Estenosis de la Válvula Mitral/complicaciones , Estenosis de la Válvula Mitral/fisiopatología , Valor Predictivo de las Pruebas , Estudios Prospectivos , Cardiopatía Reumática/complicaciones , Cardiopatía Reumática/fisiopatología , Factores de Riesgo , Índice de Severidad de la Enfermedad , Volumen Sistólico , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/fisiopatología
14.
Clin Interv Aging ; 8: 1051-4, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23966776

RESUMEN

AIMS: To evaluate the complication rate differences between elderly and younger patients who receive a permanent pacemaker implantation. METHODS: We reviewed all cases admitted to our institution between January 2008 and June 2009 with symptomatic bradyarrhythmia for whom a permanent pacemaker was implanted. Beginning in June 2009, we prospectively collected data from all patients with the same diagnosis and procedure. The frequency of complications due to the pacemaker implantation procedure was evaluated and compared between young (<70 years old) and elderly (≥70 years old) patients. RESULTS: Among 574 patients with a permanent pacemaker, 259 patients (45.1%) were below and 315 patients (54.9%) were above or at 70 years of age. There were 240 (92.7%) and 19 (7.3%) dual-chamber pacemaker (DDD) and single-chamber pacemaker (VVI) implanted patients in the younger group, and 291 (76.8%) and 73 (23.2%) DDD and VVI pacemaker implanted patients in the elderly group, respectively. The complication rate was 39 (15.1%) out of 259 young patients and 24 (7.6%) out of 315 elderly patients. Postprocedural complications were statistically lower in the elderly patients than in younger patients (P = 0.005). CONCLUSION: A pacemaker implantation performed by an experienced operator is a safe procedure for patients of advanced age. The patients who are above 70 years old may have less complication rates than the younger patients.


Asunto(s)
Marcapaso Artificial , Complicaciones Posoperatorias/epidemiología , Implantación de Prótesis/efectos adversos , Factores de Edad , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Estudios Prospectivos , Turquía/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA