Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur J Oral Sci ; 126 Suppl 1: 102-105, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30178553

RESUMEN

This paper discusses aspects of quality and safety improvement of the most commonly used dental restorative materials, the resin-based composites. From a patient's perspective, long-lasting resin-based restorations without complications are important. Recurrent caries and fracture are the most common causes for restoration failures. Proper handling and curing of the composites improve the mechanical properties of the restorations and increase safety by reducing exposure to residual methacrylate monomers. A number of compounds have been introduced in restorative materials to reduce the risk of recurrent caries, even though a real breakthrough has not yet been achieved. It is concluded that simple measures may improve the quality and safety of resin-based composite restorations.


Asunto(s)
Materiales Dentales/normas , Resinas Compuestas/efectos adversos , Resinas Compuestas/normas , Resinas Compuestas/uso terapéutico , Materiales Dentales/efectos adversos , Restauración Dental Permanente/efectos adversos , Restauración Dental Permanente/métodos , Restauración Dental Permanente/normas , Humanos , Seguridad del Paciente , Mejoramiento de la Calidad
2.
Eur J Oral Sci ; 126(6): 512-517, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30298624

RESUMEN

The present study used a new, digitized version of the impression replica technique, namely the dual-scan technique, to evaluate the adaptation of single-crown fixed dental prostheses (FDPs). Scans of the bare master model and of the master model with a silicone layer representing the cement layer were superimposed and analyzed using designated software. Single crowns produced using the lost-wax metal casting technique were included. The cement space of the band width, 0.5-1.0 mm from the preparation margin (marginal fit), was smallest for crowns made from laser-sintered cobalt-chromium. The internal fit in both mesial-distal and buccal-palatal directions was statistically significantly better for crowns made using the conventional lost-wax metal casting technique than for crowns produced using computer-aided design/computer-aided manufacturing (CAD/CAM). Fixed dental prostheses produced by milled cobalt-chromium had the loosest internal fit. The results agree with those of our previous study of the same test specimens, in which the triple-scan method was used, and imply that the dual-scan method is well suited for adaptation studies.


Asunto(s)
Diseño Asistido por Computadora , Adaptación Marginal Dental , Diseño de Prótesis Dental/métodos , Preparación Protodóncica del Diente/métodos , Aleaciones de Cromo/química , Cobalto , Coronas , Pilares Dentales , Técnica de Colado Dental , Cementos Dentales , Materiales de Impresión Dental , Técnica de Impresión Dental , Porcelana Dental/química , Dentadura Parcial Fija , Humanos , Imagenología Tridimensional , Rayos Láser , Programas Informáticos , Propiedades de Superficie , Circonio/química
3.
Eur J Oral Sci ; 126(1): 66-73, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29171091

RESUMEN

Suboptimal adaptation of fixed dental prostheses (FDPs) can lead to technical and biological complications. It is unclear if the computer-aided design/computer-aided manufacturing (CAD/CAM) technique improves adaptation of FDPs compared with FDPs made using the lost-wax and metal casting technique. Three-unit FDPs were manufactured by CAD/CAM based on digital impression of a typodont model. The FDPs were made from one of five materials: pre-sintered zirconium dioxide; hot isostatic pressed zirconium dioxide; lithium disilicate glass-ceramic; milled cobalt-chromium; and laser-sintered cobalt-chromium. The FDPs made using the lost-wax and metal casting technique were used as reference. The fit of the FDPs was analysed using the triple-scan method. The fit was evaluated for both single abutments and three-unit FDPs. The average cement space varied between 50 µm and 300 µm. Insignificant differences in internal fit were observed between the CAD/CAM-manufactured FDPs, and none of the FPDs had cement spaces that were statistically significantly different from those of the reference FDP. For all FDPs, the cement space at a marginal band 0.5-1.0 mm from the preparation margin was less than 100 µm. The milled cobalt-chromium FDP had the closest fit. The cement space of FDPs produced using the CAD/CAM technique was similar to that of FDPs produced using the conventional lost-wax and metal casting technique.


Asunto(s)
Diseño Asistido por Computadora , Técnica de Colado Dental , Diseño de Prótesis Dental/métodos , Dentadura Parcial Fija , Cerámica , Aleaciones de Cromo , Cementos Dentales , Humanos , Colado de Cera para Incrustaciones , Circonio
4.
J Prosthet Dent ; 117(3): 400-404, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27692584

RESUMEN

STATEMENT OF PROBLEM: Whether single crowns produced by computer-aided design and computer-aided manufacturing (CAD-CAM) have an internal fit comparable to crowns made by lost-wax metal casting technique is unknown. PURPOSE: The purpose of this in vitro study was to compare the internal fit of single crowns produced with the lost-wax and metal casting technique with that of single crowns produced with the CAD-CAM technique. MATERIAL AND METHODS: The internal fit of 5 groups of single crowns produced with the CAD-CAM technique was compared with that of single crowns produced in cobalt-chromium with the conventional lost-wax and metal casting technique. Comparison was performed using the triple-scan protocol; scans of the master model, the crown on the master model, and the intaglio of the crown were superimposed and analyzed with computer software. The 5 groups were milled presintered zirconia, milled hot isostatic pressed zirconia, milled lithium disilicate, milled cobalt-chromium, and laser-sintered cobalt-chromium. RESULTS: The cement space in both the mesiodistal and buccopalatal directions was statistically smaller (P<.05) for crowns made by the conventional lost-wax and metal casting technique compared with that of crowns produced by the CAD-CAM technique. CONCLUSIONS: Single crowns made using the conventional lost-wax and metal casting technique have better internal fit than crowns produced using the CAD-CAM technique.


Asunto(s)
Diseño Asistido por Computadora , Coronas , Técnica de Colado Dental , Diseño de Prótesis Dental/métodos , Aleaciones de Cromo/química , Pilares Dentales , Cementos Dentales , Técnica de Impresión Dental , Adaptación Marginal Dental , Porcelana Dental/química , Humanos , Rayos Láser , Aleaciones de Cerámica y Metal/química , Propiedades de Superficie , Circonio
5.
Clin Oral Investig ; 19(1): 61-9, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24615298

RESUMEN

OBJECTIVES: Due to incomplete curing and material degradation, cells in the oral cavity may be exposed to monomers and filler particles from dental composite fillings. The objective of the present study was to investigate if combined exposures to particles and a methacrylate monomer from composite fillings resulted in additive effects on the macrophage immune response. MATERIAL AND METHODS: Two filler particles, Nanosilica (12 nm) and Quartz (1 µm), were studied at concentrations 0.5-4 µg/cm(2), while the methacrylate monomer triethyleneglycol dimethacrylate (TEGDMA) was applied at 5 and 50 µM. RAW 264.7 macrophages were exposed to monomers and/or particles for 24 h, with a subsequent 24 h combined exposure to monomers and/or particles and the bacterial factor lipopolysaccharide (LPS) to stimulate an immune response. Release of the pro-inflammatory cytokines interleukin-1ß (IL-1ß) and tumor necrosis factor-α (TNF-α) were measured as well as the cellular viability. RESULTS: Co-exposure to Nanosilica and Quartz resulted in an additive attenuation of the LPS-induced IL-1ß release. Moreover, co-exposure to TEGDMA and both types of filler particles also resulted in an additive attenuation, although with a weak synergistic trend. The cellular viability and TNF-α release were not significantly affected by the exposures. CONCLUSION: The present findings emphasize the necessity of considering effects of combined exposure to dental degradation products in future risk assessments. CLINICAL RELEVANCE: Attenuated cytokine release could have implications for the macrophage immune response and result in impaired bacterial clearance. Further studies are necessary to determine implications for formation of dental biofilms and caries development.


Asunto(s)
Macrófagos/inmunología , Polietilenglicoles/toxicidad , Ácidos Polimetacrílicos/toxicidad , Animales , Supervivencia Celular/efectos de los fármacos , Interleucina-1beta/inmunología , Lipopolisacáridos , Ratones , Microscopía Electrónica de Rastreo , Nanopartículas/toxicidad , Cuarzo/toxicidad , Células RAW 264.7 , Dióxido de Silicio/toxicidad , Factor de Necrosis Tumoral alfa/inmunología
6.
Int Dent J ; 65(6): 311-5, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26453196

RESUMEN

OBJECTIVE: The aim of this study was to investigate the effect of silane in the repair of old and new resin-composite restorations. METHOD: Part 1: repair of old composite was performed on 60 resin-composite substrates that were 6 years old and were made of six different brands of composite. Three experiments were performed. In the first experiment, the substrates were ground flat and composite was fixed to the surface with bonding agent without silane (i.e. Clearfil Bond SE only, the control). Shear bond strength (SBS) was tested according to ISO/TS 11405 after thermocycling. In the second experiment, the same 60 substrates were ground again and treated with bis-silane a 2-part silane mixed shortly before application before applying bonding agent (Clearfil Bond SE plus silane) and repair composite before SBS testing. In the third experiment, the same substrates were ground again and a one-step bonding product containing silane (Scotchbond Universal bond containing silane) was used for the repair procedure before SBS testing. Part 2: to evaluate the repair of newly made composite restorations, 66 composite substrates were made and stored in water for 2 months. The specimens were divided into three groups and were tested using the same protocols as used to evaluate repair of old composite. RESULTS: Mean SBS (± standard deviation), in MPa, for repair of old composite was 6.2 ± 4.0 (Clearfil Bond SE only, control), 14.8 ± 7.8 (Clearfil Bond SE plus silane) and 15.3 ± 5.6 (Scotchbond Universal bond with silane), whereas for new composite mean SBS was 15.4 ± 8.6 (Clearfil Bond SE only, control), 23.4 ± 8.3 (Clearfil Bond SE with silane) and 23.7 ± 5.8 (Scotchbond Universal containing silane). A significant difference was observed between the control and the test groups with silanising agents, both in Part 1 (P < 0.001) and in Part 2 (P < 0.005). CONCLUSION: Silanising agents increase the bond strength of the resin composite repair.


Asunto(s)
Resinas Compuestas/química , Materiales Dentales/química , Silanos/química , Recubrimiento Dental Adhesivo , Humanos , Ensayo de Materiales , Cementos de Resina/química , Resistencia al Corte , Resinas de Silorano/química , Estrés Mecánico , Propiedades de Superficie , Temperatura , Factores de Tiempo , Agua/química
7.
Biomater Investig Dent ; 10(1): 2223223, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37347059

RESUMEN

Biological evaluation of resin-based dental composites has traditionally been based on in vitro endpoint tests with different methods to determine loss of cell viability and cell morphology changes after exposure to the material or monomer constituents. The data reveals a potential for biological effects, but clinical relevance of such data is limited. Positive allergy tests and allergic clinical reactions to dental monomers are observed in dental personnel and patients. The aim of this review is to address newer research on molecular events caused by exposure to resin-based composites to have a better understanding of the potential for clinical adverse effects. A more accurate understanding of the biological aspects of dental composite materials has been found after studying parameters like glutathione depletion, oxidative stress, genotoxicity, and immunomodulatory key effects in various cell culture models. Using omics-based approaches allow for a broader and non-specified search of changes caused by methacrylate exposure. Defense mechanisms and adaption are observed in cells exposed to monomer concentrations relevant to clinical exposure. The above-mentioned methods are the foundations for modified testing strategies. The clinical relevance of most available in vitro endpoint tests is of limited relevance for the patient. Research focusing on molecular mechanisms has given new insight into methacrylate toxicity in exposed cells. Using this knowledge from mechanistic studies to develop standardized in vitro biocompatibility tests will likely improve their clinical relevance.

8.
Biomater Investig Dent ; 9(1): 10-19, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35187499

RESUMEN

Objectives:The purpose of the study was to investigate the effect of ceramic surface pretreatment, effect of resin cement and dentin surface roughness on shear bond strength. Methodology: Zirconia rods (n = 140) were randomly assigned to air born particle abrasion with aluminum oxide (Al2O3) or hot etching with potassium hydrogen difluoride (KHF2). Lithium disilicate rods (LDS; n = 50) etched with hydrofluoric acid served as reference material. In Part 1 of the study, ceramic rods were cemented to bovine dentin using 5 dual-polymerizing resin cements (Variolink Esthetic, Multilink Automix (Ivoclar Vivadent), Duo-Link (BISCO Dental), Panavia F2.0 (Kuraray Dental), RelyX Unicem (3 M)). Shear bond strength was tested and fracture morphology determined. In Part 2 of the study, test groups with the highest frequency of adhesive fractures between cement and dentin were selected for further bond strength testing with different surface roughness of dentin; ground with P1200 or P80 silicon carbide paper. Dentin samples were fractured vertically to the cemented surface and the adherence between cement and dentin was studied. Results: The results of Part 1 showed that hot etching of zirconia significantly improved bond strength to Duo-Link cement. In Part 2, RelyX Unicem showed significantly higher bond strength to P1200 compared to P80 ground dentin. For Variolink Esthetic, bond strengths to P1200 and P80 ground dentin were similar. Adhesive fracture between cement and dentin dominated. Conclusions: A smooth dentin surface (P1200) improved bond strength to RelyX Unicem. Surface roughness was not important for Variolink Esthetic.

9.
Eur J Oral Sci ; 119(4): 316-22, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21726294

RESUMEN

Six commonly used composite resin materials and recommended bonding systems were tested to assess shear bond strength at the interface between aged and new composites with and without bonding. Test specimens were aged in water for 60 d before new composite was placed. Shear bond strength was assessed after 22 ± 2 h (Test 1) and after additional ageing by thermocycling (5-55°C/5,000 cycles) (Test 2). After an additional 180 d in water, the aged specimens were randomly divided into three groups to blind the test with respect to the aged composite. New composites were placed on aged specimens (two groups with and one without bonding agent) and thermocycled (Test 3). After 24 h (Test 1), the mean shear bond strength of the test specimens was 21-26 MPa when bonding agents were used, as opposed to 10-15 MPa without bonding agents. After thermocycling (Test 2), the mean shear bond strength was 16-23 MPa with a bonding agent and 17 MPa without a bonding agent. After 180 d in water and subsequent thermocycling (Test 3), the mean shear bond strength was 9-13 MPa with bonding agent and 2-3 MPa when no bonding agent was used. The results of this study therefore indicate that the use of bonding agents significantly improves the quality of composite repair.


Asunto(s)
Resinas Compuestas/química , Recubrimiento Dental Adhesivo , Cementos Dentales/química , Materiales Dentales/química , Reparación de Restauración Dental/métodos , Resinas Acrílicas/química , Recubrimientos Dentinarios/química , Humanos , Ensayo de Materiales , Metacrilatos/química , Microscopía Electrónica de Rastreo , Cementos de Resina/química , Resistencia al Corte , Resinas de Silorano , Siloxanos/química , Estrés Mecánico , Propiedades de Superficie , Temperatura , Factores de Tiempo , Agua/química
10.
Biomater Investig Dent ; 7(1): 96-104, 2020 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-32939453

RESUMEN

AIMS: The aims of this study were to present a novel method to analyse dentin bond strength and to evaluate the bond strength of combining adhesive systems and resin cement from different manufacturers. METHODS: Human wisdom teeth were ground flat to the dentin on parallel surfaces and axially cut into two parts. Dentin cylinders (Ø 3 mm) were drilled from one half of each tooth. The other half from each tooth was embedded in epoxy resin with the dentin surface exposed. The specimens were ground with silicone carbide paper and the dentin cylinders were cemented onto the dentin surface of the other half of the same tooth.Materials: Resin cement and adhesive systems from three different manufacturers were used in various combinations (n = 8 per group). Cement and adhesive from the same manufacturer served as control. Shear bond strength (SBS) was measured and fracture modes were registered.Results and conclusions: The highest median SBS value was found in a bonding combination between cement and a non-corresponding adhesive (33.1 MPa) and one of the lowest values was found in one of the controls (15.3 MPa). Cohesive fractures were most frequent. The results indicated that combining adhesive and cement from different manufacturers did not compromise the dentin bonding. The novel test method is recommended for evaluating dentin bonding.

11.
Acta Odontol Scand ; 67(6): 360-5, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19593680

RESUMEN

OBJECTIVE: Acidic fluorides are proposed for the treatment of dental erosion. The aim of this study was to examine the irritation properties of dilute hydrofluoric acid (HF) solutions for potential use in the oral cavity. MATERIAL AND METHODS: Hen's egg test-chorioallantoic membrane (HET-CAM): The CAM was accessed by careful dissection through the egg shell (n=36, 6 eggs/test solution) and exposed to 300 µl of the HF solutions (0.05%, 0.10%, 0.20%, and 1.0%) under macroscope examination over the course of 5 min. Mean time-to-coagulation and average irritation score were recorded based on appearance of hemorrhage, coagulation, and lysis of the blood vessels in the membrane. Mouse skin test: 60 male mice were randomly divided into 10 groups of 6 animals each (control, 0.05%, 0.10%, 0.20%, and 1.0% HF), shaved on the back, exposed to test solution, and euthanized after 2 h or 24 h. Skin samples were evaluated by light microscopy, scoring epithelial leukocyte infiltration, vascular congestion, and edema. RESULTS: HET-CAM: 0.05% HF was slightly irritant, 0.1% HF moderately irritant, 0.2% and 1% HF strongly irritant. 0.1-1% HF solutions were severely irritating on the eye. Mouse skin test: HF concentration was significantly correlated with tissue response, and 24-h exposure to 1% HF solution showed focal erosion of the epithelium and marked localized subepithelial leukocyte infiltration. CONCLUSION: The results of the studies suggest that accidental exposure of soft tissues to solutions containing more than 0.2% HF may be harmful.


Asunto(s)
Ácido Fluorhídrico/farmacología , Irritantes/farmacología , Animales , Quimiotaxis de Leucocito/efectos de los fármacos , Embrión de Pollo , Membrana Corioalantoides/irrigación sanguínea , Membrana Corioalantoides/efectos de los fármacos , Edema/inducido químicamente , Epitelio/efectos de los fármacos , Epitelio/patología , Ojo/efectos de los fármacos , Hemorragia/inducido químicamente , Ácido Fluorhídrico/administración & dosificación , Hiperemia/inducido químicamente , Masculino , Ratones , Ratones Endogámicos C57BL , Ratones Endogámicos , Microvasos/efectos de los fármacos , Distribución Aleatoria , Piel/irrigación sanguínea , Piel/efectos de los fármacos , Factores de Tiempo
12.
J Biomed Mater Res A ; 107(4): 851-859, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30597736

RESUMEN

Resin-based biomaterials are widely used in medical and dental treatment, and both clinicians and patients are exposed to the materials. The knowledge of toxicity is mainly based on in vitro studies at exposure concentrations that induce cell death. However, severe cell damage and cell death signaling may overshadow essential cellular events caused by a possible toxicant. For dental resins, the knowledge of interaction with living cells at more clinical relevant exposure doses is sparse. 2-Hydroxyethylmethacrylate (HEMA) is a commonly used monomer in dental resins. Measuring cellular adaptation to HEMA at concentrations that did not reduce cell viability was the main focus of this study. Stable isotope labeling with amino acids in cell culture was used to measure proteome changes in cultured THP-1 cells exposed to HEMA. Western blotting verified the results. Cells exposed to HEMA increased their level of several cytoprotective proteins. The observed adaptation is compatible with increased oxidative burden caused by GSH depletion and the electrophilic characteristic of HEMA. The present approach to analyzing the toxic potential of HEMA yielded information on interactions with living cells is not previously reported. This detailed information is of great value to make better predictions of possible side effects in the clinic. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 107A: 851-859, 2019.


Asunto(s)
Metacrilatos/farmacología , Proteoma/metabolismo , Resinas Sintéticas/farmacología , Humanos , Células THP-1
13.
Dent Mater ; 24(9): 1201-6, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18336898

RESUMEN

OBJECTIVES: Silica-glass fiber reinforced polymers can be used for many kinds of dental applications. The fiber reinforcement enhances the mechanical properties of the polymers, and they have good esthetic attributes. There is good initial bonding of glass fibers to polymers via an interface made from silane coupling agents. The aim of this in vitro study was to determine the cytotoxicity of two polymers reinforced with two differently sized silica-glass fibers before and after thermal cycling. Cytotoxicity of the polymers without fibers was also evaluated. METHODS: Two different resin mixtures (A and B) were prepared from poly(vinyl chloridecovinylacetate) powder and poly(methyl methacrylate) (PMMA) dissolved in methyl methacrylate and mixed with different cross-linking agents. The resin A contained the cross-linking agents ethylene glycol dimethacrylate and 1,4-butanediol dimethacrylate, and for resin B diethylene glycol dimethacrylate was used. Woven silica-glass fibers were used for reinforcement. The fibers were sized with either linear poly(butyl methacrylate)-sizing or cross-linking PMMA-sizing. Cytotoxicity was evaluated by filter diffusion test (ISO 7405:1997) of newly made and thermocycled test specimens. Extracts were prepared according to ISO 10993-12 from newly made and from thermocycled specimens and tested by the MTT assay. The results from the experiments were statistically analyzed by one-way ANOVA and Tukey's test (rho<0.05). RESULTS: The filter diffusion test disclosed no change in staining intensity at the cell-test sample contact area indicating non-cytotoxicity in all experimental groups. Cell viability assessed by MTT assay was more than 90% in all experimental groups. All are non-cytotoxic. SIGNIFICANCE: It can be concluded that correctly processed heat polymerized silica-glass fiber reinforced polymers induced no cytotoxicity and that thermocycling did not alter this property.


Asunto(s)
Resinas Compuestas/toxicidad , Materiales Dentales/toxicidad , Vidrio/química , Dióxido de Silicio/toxicidad , Acrilatos/toxicidad , Animales , Supervivencia Celular/efectos de los fármacos , Colorantes , Reactivos de Enlaces Cruzados/toxicidad , Glicoles de Etileno/toxicidad , Fibroblastos/efectos de los fármacos , Ensayo de Materiales , Metacrilatos/toxicidad , Metilmetacrilato/toxicidad , Ratones , Ácidos Polimetacrílicos/toxicidad , Polimetil Metacrilato/toxicidad , Polivinilos/toxicidad , Propiedades de Superficie , Temperatura , Sales de Tetrazolio , Tiazoles
14.
Dent Mater ; 23(1): 34-9, 2007 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-16430953

RESUMEN

OBJECTIVES: Cytotoxic methacrylate monomers have been identified in aqueous extracts of freshly cured compomers. Some of these compounds, including HEMA and TEGDMA, induce apoptosis and necrosis in vitro. The aim of the present study was to elucidate possible signaling pathways involved in apoptosis following exposure to HEMA or TEGDMA in a salivary gland cell line. METHODS: The cells were exposed to various concentrations of HEMA or TEGDMA. ROS formation was determined by dichlorofluorescein assay. Phosphorylated MAP-kinases ERK1/2, p38 and JNK, as well as specific caspases were identified by Western blotting. Apoptosis was assayed by fluorescence microscopy. RESULTS: HEMA or TEGDMA exposure resulted in ROS formation and concentration-dependent apoptosis as well as phosphorylation of ERK. Phosphorylation of JNK and p38 was induced by HEMA. Selective inhibitors of ERK and JNK modified the apoptotic response after HEMA and TEGDMA exposure, whereas p38 inhibition modified the apoptotic response only after HEMA exposure. Vitamin C reduced HEMA-induced apoptosis. SIGNIFICANCE: ROS formation and differential MAP kinase activation appear to be involved in the apoptotic response following exposure to HEMA and TEGDMA.


Asunto(s)
Apoptosis/efectos de los fármacos , Materiales Dentales/farmacología , MAP Quinasa Quinasa 4/metabolismo , Metacrilatos/farmacología , Proteínas Quinasas Activadas por Mitógenos/metabolismo , Polietilenglicoles/farmacología , Ácidos Polimetacrílicos/farmacología , Especies Reactivas de Oxígeno/metabolismo , Proteínas Quinasas p38 Activadas por Mitógenos/metabolismo , Animales , Antioxidantes/farmacología , Ácido Ascórbico/farmacología , Western Blotting , Caspasas/metabolismo , Línea Celular , Activación Enzimática/efectos de los fármacos , Flavonoides/farmacología , Colorantes Fluorescentes , MAP Quinasa Quinasa 4/antagonistas & inhibidores , Proteínas Quinasas Activadas por Mitógenos/antagonistas & inhibidores , Ratas , Transducción de Señal/efectos de los fármacos , Factores de Tiempo , Proteínas Quinasas p38 Activadas por Mitógenos/antagonistas & inhibidores
15.
Acta Odontol Scand ; 65(5): 275-83, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17851830

RESUMEN

OBJECTIVE: This study was undertaken to determine the potential of dental adhesive products to induce mucosal irritation based on their ability to damage the blood vessels of the chorioallantoic membrane (CAM) in fertilized hen's egg. MATERIAL AND METHODS: Twenty-seven dental adhesive products (total 36 solutions) covering the four adhesive concepts,etch and rinse with two or three steps procedure and self-etch with one or two steps procedure, were evaluated using the hen's egg test-CAM method (HET-CAM). The blood vessels on the CAM of a fertilized hen's egg were used as the test system, and severity of the irritation was based on an assessment of the reaction of the blood and the blood vessels to the test chemical during 5 min of exposure. Three specific end-points - coagulation of blood, lyses of blood and rupture of blood vessel - were evaluated and their time-points for appearance noted. RESULTS: Coagulation of the blood was the most frequent injury, and was observed within less than a minute's exposure in 25 of the 36 tested solutions. Seventeen of the solutions were rated as moderate irritants and 16 as strong irritants. The type and severity of reaction could not be linked to the type of solvent (water, ethanol, acetone) nor to the presence of 2-hydroxylethyl methacrylate (2-HEMA) in the products. Conclusions. Most dental adhesives damage the blood vessels of the CAM, indicating irritant effects on mucous membranes.


Asunto(s)
Membrana Corioalantoides/efectos de los fármacos , Cementos Dentales/toxicidad , Animales , Coagulación Sanguínea , Vasos Sanguíneos/efectos de los fármacos , Embrión de Pollo , Membrana Corioalantoides/irrigación sanguínea , Cementos Dentales/química , Hemólisis , Hemorragia/inducido químicamente
16.
Am J Orthod Dentofacial Orthop ; 132(6): 789-95, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18068598

RESUMEN

INTRODUCTION: Our aims in this study were to assess adverse patient reactions during orthodontic treatment with nickel-containing appliances and to investigate the need for and the use of nickel-free devices in orthodontic practices in Finland and Norway. METHODS: A questionnaire was mailed to orthodontists and dentists versed in orthodontics in both countries. They were asked to retrospectively assess the number of patients with adverse reactions and to describe the reactions, the appliances used, and any implications on treatment. Previous history of nickel allergy of patients with adverse reactions, and use of and need for nickel-free appliances in clinical practice were also addressed. RESULTS: Forty-six percent of the respondents (n = 298) reported at least 1 adverse patient reaction during the last 5 years. More than half of the reactions had implications for the treatment. Finnish respondents observed significantly more adverse patient reactions than their Norwegian colleagues, and, in Finland, the adverse reactions were most frequently attributed to headgear treatment. Using nickel-containing fixed appliances in nickel-allergic patients was more common in Finland (77% of the respondents) than in Norway (65%). CONCLUSIONS: Nearly half of the dentists regularly working with fixed appliances had observed at least 1 adverse patient reaction during treatment. Nickel-containing fixed appliances are generally used in most patients-even those with a suspected nickel allergy.


Asunto(s)
Aleaciones Dentales/efectos adversos , Hipersensibilidad Tardía/etiología , Níquel/efectos adversos , Aparatos Ortodóncicos/efectos adversos , Finlandia , Humanos , Modelos Logísticos , Noruega , Estudios Retrospectivos , Encuestas y Cuestionarios
17.
Acta Biomater Odontol Scand ; 3(1): 21-29, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28642928

RESUMEN

Objectives: To evaluate the micro-tensile repair bond strength between aged and new composite, using silane and adhesives that were cured or left uncured when new composite was placed. Methods: Eighty Filtek Supreme XLT composite blocks and four control blocks were stored in water for two weeks and thermo-cycled. Sandpaper ground, etched and rinsed specimens were divided into two experimental groups: A, no further treatment and B, the surface was coated with bis-silane. Each group was divided into subgroups: (1) Adper Scotchbond Multi-Purpose, (2) Adper Scotchbond Multi-Purpose adhesive, (3) Adper Scotchbond Universal, (4) Clearfil SE Bond and (5) One Step Plus. For each adhesive group, the adhesive was (a) cured according to manufacturer's instructions or (b) not cured before repair. The substrate blocks were repaired with Filtek Supreme XLT. After aging, they were serially sectioned, producing 1.1 × 1.1 mm square test rods. The rods were prepared for tensile testing and tensile strength calculated at fracture. Type of fracture was examined under microscope. Results: Leaving the adhesive uncured prior to composite repair placement increased the mean tensile values statistically significant for all adhesives tested, with or without silane pretreatment. Silane surface treatment improved significantly (p < 0.001) tensile strength values for all adhesives, both for the cured and uncured groups. The mean strength of the control composite was higher than the strongest repair strength (p < 0.001). Conclusions: Application of freshly made silane and a thin bonding layer, rendered higher tensile bond strength. Not curing the adhesive before composite placement increased the tensile bond strength.

18.
Dent Mater ; 22(7): 630-40, 2006 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-16223522

RESUMEN

OBJECTIVES: In vitro exposure to chemical compounds in dental materials may cause cell death by apoptosis, necrosis or a combination of both. The aim of this paper was to evaluate aqueous extracts of freshly cured compomers Freedom (SDI) and F2000 (3M ESPE), and constituents identified in the extracts, GDMA (glycerol dimethacrylate), TEGDMA (triethylene glycol dimethacrylate) and HEMA (2-hydroxyethyl methacrylate) for their ability to induce necrosis and apoptosis in primary rat alveolar macrophages and the J744A1 macrophage cell line. METHODS: The cells were exposed to either extracts of freshly cured samples of the products or to one of the constituents identified in the extracts. Cytotoxicity and necrosis were assayed by MTT test and fluorescence microscopy, respectively. Apoptosis was assayed by fluorescence microscopy and flow cytometry. RESULTS: Concentration-related apoptosis and necrosis were found in both cell types after exposure to extracts from Freedom and F2000. GDMA appeared to be the most cytotoxic of the tested constituents in the J744A1 cell line as evaluated by the MTT test. TEGDMA was more cytotoxic than HEMA using the MTT test and fluorescence microscopy, whereas HEMA caused a greater accumulation of apoptotic cells seen by fluorescence microscopy and flow cytometry. For various concentrations of HEMA and TEGDMA, the extent of apoptosis appeared inversely related to the cytotoxicity evaluated by the MTT test. SIGNIFICANCE: As an apoptotic response elicits less inflammatory response in the surrounding tissues than a necrotic process, the role of cell death pattern could be important for the evaluation of the biocompatibility of dental materials.


Asunto(s)
Compómeros/toxicidad , Macrófagos/efectos de los fármacos , Animales , Apoptosis , Supervivencia Celular/efectos de los fármacos , Células Cultivadas , Citometría de Flujo , Cementos de Ionómero Vítreo/toxicidad , Masculino , Metacrilatos/toxicidad , Ratones , Necrosis , Polietilenglicoles/toxicidad , Ácidos Polimetacrílicos/toxicidad , Ratas
19.
Biomater Investig Dent ; 8(1): 180, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34913040
20.
Biomater Investig Dent ; 7(1): 158, 2020 Oct 14.
Artículo en Inglés | MEDLINE | ID: mdl-33179014
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA