Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Molecules ; 26(9)2021 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-33946509

RESUMEN

The simultaneous determination of chemical vapor-generating elements involving derivatization is difficult even by inductively coupled plasma optical emission spectrometry or mass spectrometry. This study proposes a new direct liquid microsampling method for the simultaneous determination of As, Bi, Se, Te, Hg, Pb, and Sn, using a fully miniaturized set-up based on electrothermal vaporization capacitively coupled plasma microtorch optical emission spectrometry. The method is cost-effective, free from non-spectral interference, and easy to run by avoiding derivatization. The method involves the vaporization of analytes from the 10 µL sample and recording of episodic spectra generated in low-power (15 W) and low-Ar consumption (150 mL min-1) plasma microtorch interfaced with low-resolution microspectrometers. Selective vaporization at 1300 °C ensured the avoidance of non-spectral effects and allowed the use of external calibration. Several spectral lines for each element even in the range 180-210 nm could be selected. Generally, this spectral range is examined with large-scale instrumentation. Even in the absence of derivatization, the obtained detection limits were low (0.02-0.75 mg kg-1) and allowed analysis of environmental samples, such as cave and river sediments. The recovery was in the range of 86-116%, and the accuracy was better than 10%. The method is of general interest and could be implemented on any miniaturized or classical laboratory spectrometric instrumentation.

2.
Acta Chim Slov ; 57(1): 173-81, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24061670

RESUMEN

Non-spectral interference of easily ionized elements (EIEs) as chlorides and Al as AlCl3 and Al(NO3)3 on the emission of Ca II 393.367 nm, Ca I 422.673 nm, CaOH 554 nm and 622 nm were studied in a medium power radiofrequency capacitively coupled Ar plasma (275 W, 27.12 MHz) with single (SRTrfCCP) and double ring electrode (DRTrfCCP). The mechanisms of interferences were explained based on the matrix energy demand (MED) supposing the local thermal equilibrium (LTE) in plasma, emphasizing also processes contrasting with this model. Matrix effects were found to be dependent on the coupling geometry of the rf power to the torch, observation height, emitting Ca species and EIEs matrix nature but independent from Al as regards its salt origin. The magnitude of the matrix effects was correlated with the electron number density and the discharge temperature. The optimization of the observation height and use of the DRT geometry allowed the reduction of EIEs and Al matrix effects on the emission of Ca species compared to SRT. The best Ca detection limits in SRTrfCCP were at CaOH 622 nm (106-450 ng ml-1), while in DRTrfCCP at Ca I 422.673 nm (92-145 ng ml-1).

3.
Talanta ; 217: 121067, 2020 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-32498880

RESUMEN

An analytical method for the quantification of total Hg and CH3Hg+ in biological tissues (fish, mushroom) and water sediment was developed based on small-sized electrothermal vaporization capacitively coupled plasma microtorch optical emission spectrometry using a low-resolution microspectrometer as detector. Sample preparation was carried out according to the procedure recommended by JRC Technical Report of European Commission for the determination of CH3Hg+ in seafood and adapted by us for lower consumption of reagents. Amounts of 0.1 - 0.5 g sample were subjected to extraction in 5 ml of 47% HBr then CH3Hg+ was extracted in 2 × 1 ml toluene and back-extracted in 2 ml aqueous solution of 1% l-cysteine. Total Hg/CH3Hg+ were quantified in 10 µl of acidic extract/l-cysteine solution after electrothermal vaporization and measurement of 253.652 nm Hg signal in the episodic emission spectra. Under the optimal working conditions of system (70 °C sample drying, 1300 °C sample vaporization, 10 W plasma power and 150 ml min-1 Ar flow) the limits of detection were 7.0 µg kg-1 total Hg and 3.5 µg kg-1 CH3Hg+. Comparison of slopes in external calibration and standard addition procedure revealed the lack of non-spectral interferences of multimineral matrix, so that the calibration against Hg2+ standards was adopted. Pooled recovery of total mercury/methylmercury was 101 ± 7%/100 ± 7%, while precision assessed from measurements of real samples was in the range 1.6-9.6%/2.7-12.8%. The proposed method validated according to Eurachem Guide 2014 is selective and complies with demands in European legislation (Decisions 657/2002; 333/2007; 836/2011) and Association of Official Analytical Chemists Guide in terms of performances for food control. The method displays a high degree of greenness by circumventing cold vapor generation, use of small amounts of reagents and full-miniaturized instrumentation resulting in low analytical costs without reducing results quality. Besides, the method is simple and rapid, since it uses external calibration curves prepared from Hg2+standard solutions both for total Hg and CH3Hg+ determination.

4.
J Biochem Biophys Methods ; 70(6): 1234-9, 2008 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-17604113

RESUMEN

The zinc content of 3 microL of vegetal samples (tree leaves, lichens and grape sap) atomized from a Pt-wire in the methane-air flame has been determined by atomic absorption spectrometry. The effect of gas flow rates and the atomization height in the flame on the absorption of zinc was evaluated at 213.9 nm. The best results were obtained at a height of 5 mm and gas flow rates of 200 L/h air and 26 L/h methane, respectively. The effect of Na, K, Ca, Mg, SO4(2-), and PO4(3-) on the absorption of zinc was studied too. The detection limit of 0.40+/-0.21 ng was obtained at a significance level of 0.05, using the two-step Neyman-Pearson criterion. The zinc content of the samples has been determined with continuous nebulization and by atomization from the Pt-wire, using both the standard calibration curve and the standard addition method. The results of the two procedures agree within the determination errors.


Asunto(s)
Líquenes/química , Platino (Metal)/química , Espectrofotometría Atómica/métodos , Vitis/química , Zinc/análisis , Calibración , Hojas de la Planta/química , Zinc/química
5.
Talanta ; 170: 464-472, 2017 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-28501197

RESUMEN

A non-chromatographic method based on double liquid-liquid extraction and measurements by UV photochemical vapor generation capacitively coupled plasma microtorch optical emission spectrometry was developed and characterized for methylmercury determination in seafood. Samples were prepared following the procedure recommended in JRC Technical Report of European Commission formerly proposed for the determination of methylmercury in seafood by thermal decomposition atomic absorption spectrometry, namely confinement of Hg species in 47% HBr solution, extraction of CH3Hg+ in toluene and back-extraction in 1% l-cysteine aqueous solution. Mercury cold vapor was generated by flow injection UV photo-reduction from CH3Hg+ in 0.6molL-1 HCOOH, while quantification was performed against external Hg2+ aqueous standards and measuring Hg 253.652nm emission using a low power/Ar consumption plasma microtorch (15W, 100mLmin-1) and a low resolution microspectrometer (Ocean Optics). The figures of merit and analytical capability were assessed by analyzing certified reference materials and test samples of fish fillet and discussed in relation with requirements for Hg determination in seafood in European legislation (Decisions 2007/333/EC and 2002/657/EC) as well as compared to performances achieved in thermal decomposition atomic absorption spectrometry. The limit of detection and quantification of 2µgkg-1 and 6µgkg-1 respectively, precision of 2.7-9.4% and accuracy of 99±8% of the proposed method for the determination of CH3Hg+ fulfill the demands of European legislation for Hg quantification. The limit of detection and quantification were better than those in the used reference method or other non-/chromatographic methods taken for comparison. The analysis of certified reference materials and the Bland and Altman test performed on 12 test samples confirmed trueness of the proposed method and its reliability for the determination of traces of CH3Hg+ with 95% confidence level. The proposed method fulfills several demands of the eco-scale concept, is sensitive, simple and safe related to sample preparation through elimination of classical, harmful reductants and attractive by using economical miniaturized instrumentation incorporating a low power and low Ar consumption plasma.


Asunto(s)
Análisis de los Alimentos/métodos , Compuestos de Metilmercurio/análisis , Alimentos Marinos/análisis , Espectrofotometría Atómica/métodos , Contaminantes Químicos del Agua/análisis , Animales , Diseño de Equipo , Peces , Análisis de los Alimentos/instrumentación , Límite de Detección , Reproducibilidad de los Resultados , Espectrofotometría Atómica/instrumentación
6.
Talanta ; 129: 72-8, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25127566

RESUMEN

A low power and low argon consumption (13.56 MHz, 15 W, 150 ml min(-1)) capacitively coupled plasma microtorch interfaced with a low-resolution microspectrometer and a small-sized electrothermal vaporization Rh coiled-filament as liquid microsample introduction device into the plasma was investigated for the simultaneous determination of several volatile elements of interest for environment. Constructive details, spectral and analytical characteristics, and optimum operating conditions of the laboratory equipment for the simultaneous determination of Ag, Cd, Cu, Pb and Zn requiring low vaporization power are provided. The method involves drying of 10 µl sample at 100°C, vaporization at 1500°C and emission measurement by capture of 20 successive spectral episodes each at an integration time of 500 ms. Experiments showed that emission of elements and plasma background were disturbed by the presence of complex matrix and hot Ar flow transporting the microsample into plasma. The emission spectrum of elements is simple, dominated by the resonance lines. The analytical system provided detection limits in the ng ml(-1) range: 0.5(Ag); 1.5(Cd); 5.6(Cu); 20(Pb) and 3(Zn) and absolute detection limits of the order of pg: 5(Ag); 15(Cd); 56(Cu); 200(Pb) and 30(Zn). It was demonstrated the utility and capability of the miniaturized analytical system in the simultaneous determination of elements in soil and water sediment using the standard addition method to compensate for the non-spectral effects of alkali and earth alkaline elements. The analysis of eight certified reference materials exhibited reliable results with recovery in the range of 95-108% and precision of 0.5-9.0% for the five examined elements. The proposed miniaturized analytical system is attractive due to the simple construction of the electrothermal vaporization device and microtorch, low costs associated to plasma generation, high analytical sensitivity and easy-to-run for simultaneous multielemental analysis of liquid microsamples.


Asunto(s)
Electroquímica/métodos , Espectrofotometría Atómica/métodos , Oligoelementos/análisis , Cadmio/análisis , Cobre/análisis , Sedimentos Geológicos/química , Plomo/análisis , Límite de Detección , Óptica y Fotónica , Reproducibilidad de los Resultados , Plata/análisis , Contaminantes del Suelo/análisis , Temperatura , Volatilización , Zinc/análisis
7.
Talanta ; 109: 84-90, 2013 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-23618143

RESUMEN

A sensitive method using a miniature analytical system with a capacitively coupled plasma microtorch (25 W, 13.56 MHz, 0.4 l min(-1) Ar) was developed and evaluated for the determination of As and Sb in recyclable plastics and biodegradable materials by hydride generation optical emission spectrometry. Given their toxicity, As and Sb should be subject to monitoring in such materials despite not being included within the scope of Restriction of Hazardous Substances Directive. The advantages of the proposed approach are better detection limits and lower analysis cost relative to conventional systems based on inductively coupled plasma optical emission and flame atomic absorption spectrometry with/without derivatization. Samples were subjected to acidic microwave-assisted digestion in a nitric-sulfuric acid mixture. Chemical hydride generation with 0.5% NaBH4 after the prereduction of As(V) and Sb(V) with 0.3% L-cysteine in 0.01 mol l(-1) HCl (10 min contact time at 90±5°C) was used. Under the optimal hydride generation conditions and analytical system operation the detection limits (mg kg(-1)) were 0.5 (As) and 0.1 (Sb), whereas the precision was 0.4-7.1% for 10.2-46.2 mg kg(-1) As and 0.4-3.2% for 7.1-156 mg kg(-1) Sb. Analysis of two polyethylene CRMs revealed recoveries of 101±2% As and 100±1% Sb.


Asunto(s)
Antimonio/análisis , Arsénico/análisis , Polietilenos/química , Espectrofotometría Atómica/métodos , Biodegradación Ambiental , Diseño de Equipo , Límite de Detección , Reciclaje , Reproducibilidad de los Resultados , Espectrofotometría Atómica/instrumentación
8.
Food Chem ; 134(4): 2447-52, 2012 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-23442709

RESUMEN

A method for multielemental (Ca, Cr, Cu, Fe, K, Mg, Mn, Na, P and Zn) determination in multimineral/multivitamins by atomic emission spectrometry in a medium power radiofrequency capacitively coupled plasma (275 W) and low Ar consumption (0.4 L min(-1)) is proposed. Determinations were performed on commercially available tablets and a standard reference material after acidic high-pressure microwave assisted digestion and using the standard additions procedure. The detection limits (mg g(-1)) were in the range 0.003 (Na)-1.5 (P) and were not depreciated by the non-spectral interference of mineral matrices of K, Ca, Mg and Na excepting Zn and P. Found concentrations corresponded generally to the labelled contents with recovery in the range of 90-107% and 1.0-13.0% repeatability. The proposed technique could be an advantageous alternative to the more expensive inductively coupled plasma atomic emission spectrometry in the quality control of multimineral/multivitamin preparations.


Asunto(s)
Minerales/análisis , Espectrofotometría Atómica/métodos , Vitaminas/análisis , Límite de Detección , Control de Calidad , Espectrofotometría Atómica/instrumentación
9.
J Hazard Mater ; 193: 65-9, 2011 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-21802847

RESUMEN

A new analytical system consisting of a low power capacitively coupled plasma microtorch (20 W, 13.56 MHz, 150 ml min(-1) Ar) and a microspectrometer was investigated for the Hg determination in non- and biodegradable materials by cold-vapor generation, using SnCl(2) reductant, and atomic emission spectrometry. The investigated miniaturized system was used for Hg determination in recyclable plastics from electronic equipments and biodegradable materials (shopping bags of 98% biodegradable polyethylene and corn starch) with the advantages of easy operation and low analysis costs. Samples were mineralized in HNO(3)-H(2)SO(4) mixture in a high-pressure microwave system. The detection limits of 0.05 ng ml(-1) or 0.08 µg g(-1) in solid sample were compared with those reported for other analytical systems. The method precision was 1.5-9.4% for Hg levels of 1.37-13.9 mg kg(-1), while recovery in two polyethylene certified reference materials in the range 98.7 ± 4.5% (95% confidence level).


Asunto(s)
Materiales Biocompatibles , Mercurio/análisis , Análisis Espectral/métodos , Miniaturización
10.
Talanta ; 76(5): 1170-6, 2008 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-18761173

RESUMEN

The single ring electrode radiofrequency capacitively coupled plasma torch (SRTr.f.CCP) operated at 275W, 27.12 MHz and Ar flow rate below 0.7 lmin(-1) was investigated for the first time as atomization cell in atomic fluorescence spectrometry (AFS) using electrodeless discharge lamps (EDL) as primary radiation source and charged coupled devices as detector. The signal to background ratio (SBR) and limit of detection for Cd determination by EDL-SRTr.f.CCP-AFS were compared to those obtained in atomic emission spectrometry using the same plasma torch. The detection limit in fluorescence was 4.3 ngml(-1) Cd compared to 65 ngml(-1) and 40 ngml(-1) reported in r.f.CCP-atomic emission (AES) equipped with single or double ring electrode. The lower detection limit in EDL-SRTr.f.CCP-AFS is due to a much better SBR in fluorescence. The limit of detection was also compared to those in atomic fluorescence with inductively coupled plasma (0.4 ngml(-1)), microwave plasma torch (0.25 ngml(-1)) and air-acetylene flame (8 ngml(-1)). The influence of light-scattering through the plasma and the secondary reflection of the primary radiation on the wall of the quartz tube on the analytical performance are discussed. The non-spectral matrix effects of Ca, Mg and easily ionized elements are much lower in EDL-SRTr.f.CCP-AFS compared to SRTr.f.CCP-AES. The new technique was applied in the determination of Cd in contaminated soils, industrial hazardous waste (0.4-370 mgkg(-1)) and water (113 microgl(-1)) with repeatability of 4-8% and reproducibility in the range of 5-12%, similar to those in ICP-AES. The results were checked by the analysis of a soil and water CRM with a recovery degree of 97+/-9% and 98+/-4%, for a confidence limit of 95%. The present EDL-SRTr.f.CCP-AFS is a promising technique for Cd determination in environmental samples.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA