Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Surg Res ; 299: 366-373, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38815523

RESUMEN

INTRODUCTION: Lesions of uncertain malignant potential (B3) represent 10% of core needle biopsies (CNBs) or vacuum-assisted breast biopsies (VABBs). Traditionally, B3 lesions are operated on. This study investigated the association between B3 subtypes and malignancy to determine the best management. METHODS: Pre- and postoperative histological reports from 226 patients, who had undergone excisional surgery for B3 lesions, following CNB or VABB, were retrospectively analyzed. The correlation between the CNB/VABB diagnosis and the final pathology was investigated, along with the correlation between malignancy upgrade and the type of mammographic lesion. The positive predictive value (PPV) of malignancy of B3 lesions was calculated by simple logistic regression. Patients without cancer diagnosis underwent a 7-y follow-up. RESULTS: Pathology showed 171 (75.6%) benign and 55 (24.3%) malignant lesions. The PPV was 24.3% (P = 0.043), including 31 (13.7%) ductal carcinomas in situ and 24 (10.6%) invasive carcinomas. The most frequently upgraded lesions were atypical ductal hyperplasia, 34.2% (P = 0.004), followed by lobular intraepithelial neoplasia, 27.5% (P = 0.025). The median diameter of mammographic lesions was 1.5 [0.9-2.5] cm, while for surgical specimens, it was 5 [4-7] cm (P < 0.0001). Mammographic findings and histology showed a significant correlation (P = 0.038). After a 7-y follow-up, 15 (8.9%) patients developed carcinoma, and 7 patients (4%) developed a new B3 lesion. CONCLUSIONS: We can conclude that atypical ductal hyperplasia and lobular intraepithelial neoplasia still require surgery for a significant PPV. Other types that lacked significance or confidence intervals were too wide to draw any conclusion.


Asunto(s)
Neoplasias de la Mama , Valor Predictivo de las Pruebas , Humanos , Femenino , Neoplasias de la Mama/patología , Neoplasias de la Mama/cirugía , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/diagnóstico por imagen , Persona de Mediana Edad , Estudios Retrospectivos , Adulto , Anciano , Estudios de Seguimiento , Biopsia con Aguja Gruesa , Mamografía , Mama/patología , Mama/diagnóstico por imagen , Mama/cirugía , Carcinoma Intraductal no Infiltrante/patología , Carcinoma Intraductal no Infiltrante/diagnóstico , Carcinoma Intraductal no Infiltrante/cirugía , Carcinoma Ductal de Mama/patología , Carcinoma Ductal de Mama/cirugía , Carcinoma Ductal de Mama/diagnóstico , Carcinoma Ductal de Mama/diagnóstico por imagen , Anciano de 80 o más Años
2.
Radiol Med ; 128(5): 528-536, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37029852

RESUMEN

PURPOSE: In recent years vacuum-assisted excision (VAE) has been described as an alternative treatment for some B3 lesions. This study aims to assess the effectiveness of using VAE to manage selected B3 lesions by quantifying the number of B3 lesions undergoing VAE, the malignant upgrade rate, and the complications encountered. MATERIALS AND METHODS: Our department evaluated all B3 lesions diagnosed between January 2019 and October 2021 and treated them with VAE. The data were collected during the initial biopsy and final histology based on VAE image guidance, also considering initial lesions and complications. The exclusion criteria were: B3 lesion of size > 20 mm, presence of a concomitant malignant lesion, lesion < 5.0 mm distant from the skin, nipple or pectoral muscle, phyllodes tumours or indeterminate B3 lesions. Lesions that upgraded to malignancy underwent surgical excision, while benign lesions performed radiological follow-ups. RESULTS: From 416 B3 lesions diagnosed, 67 (16.1%) underwent VAE. VAE was performed under X-ray (50/67) or ultrasound guidance (17/67). Five cases (7.5%) upgraded to a malignant lesion, 2 ADH, 2 LIN and one papillary lesion that underwent surgery. No malignancy or new lesions has occurred at the site of the VAE, with an average radiological follow-up of 14.9 months. CONCLUSIONS: VAE could be a safe and effective pathway for managing selected B3 lesions. Lesions initially subjected to CNB with ADH and LN outcome, before undergoing VAE, should perform a VAB for better tissue characterization and management.


Asunto(s)
Neoplasias de la Mama , Mama , Humanos , Femenino , Mama/diagnóstico por imagen , Biopsia , Mamografía , Ultrasonografía , Vacio , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Neoplasias de la Mama/patología , Estudios Retrospectivos
3.
Radiol Med ; 126(7): 936-945, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33900526

RESUMEN

PURPOSE: The aim of our work is to illustrate a new technique for the histological diagnosis of Paget's disease (PD) using a core needle biopsy with a semiautomated 14-gauge needle called nipple-core needle biopsy (N-CNB). We report 3 years' experience in our senology unit. MATERIALS AND METHODS: Twenty-six women with 26 clinical of nipple-areola complex (NAC) changes with suspected PD and subjected to core needle biopsy using our new 14G semiautomated needle technique were included in our study group. Institutional review board approval was obtained for this retrospective analysis. A semiautomated biopsy gun with a 14-gauge, 15-cm-long needle was used for this new procedure. After a subcutaneous injection of anesthetic and spray-ice application to the NAC, the 14G needle was opened with the cradle exposed and positioned on the NAC with considerable pressure exerted on the same. The cradle was then closed by triggering the needle spring, and 2-4 core samples were withdrawn by moving the needle position each time. Clinical, instrumental and histological differences between the lesions that gave benign results after N-CNB and those that resulted PD were analyzed by applying the Fisher's exact test. RESULTS: After N-CNB, 13/26 lesions were found to be PD (50%) while 13/26 alterations were benign (50%). No malignant lesions were detected during the follow-up in patients with benign N-CNB results. The diagnosis of PD obtained with N-CNB was confirmed in all 13 cases by means of a histological analysis of the surgical specimens. No significant post-biopsy complications were recorded. Patients with PD more frequently presented nipple retraction (ρ = 0.0407) and associated suspicious (i.e., BI-RADS 4 and 5) mammographic (ρ = 0.0006) findings compared to patients whose N-CNB had given benign results and the difference was statistically significant. CONCLUSIONS: In conclusion, with this novel technique, we were able to obtain an easy, painless, major complication-free and accurate diagnosis of PD of the NAC using a semiautomated core needle biopsy with a 14-gauge needle.


Asunto(s)
Biopsia con Aguja Gruesa/instrumentación , Neoplasias de la Mama/diagnóstico , Mama/diagnóstico por imagen , Enfermedad de Paget Mamaria/diagnóstico , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Diseño de Equipo , Femenino , Humanos , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Ultrasonografía Mamaria/métodos , Adulto Joven
4.
Breast J ; 26(7): 1276-1283, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-31999029

RESUMEN

One of the most important indications for contrast-enhanced breast imaging is the presurgical breast cancer (BC) staging. This is a large-scale single-center experience which evaluates the role of CEDM in presurgical staging and its impact on surgical planning. The aims of this retrospective study were to define the diagnostic performance of CEDM in the presurgical setting and to identify which types of patients could benefit from having CEDM. We selected 326 patients with BC who underwent CEDM as preoperative staging and had breast cancer-related surgery at our institution. We analyzed those cases in which CEDM led to additional imaging or biopsy and those in which it changed the type of surgery that was planned according to conventional breast imaging (CI) techniques (digital mammography, tomosynthesis and bilateral handheld ultrasound). CEDM sensitivity in identifying the index lesion and sensitivity, specificity, positive (PPV) and negative (NPV) predictive values, and accuracy in the correct preoperative staging of BC of the whole population and in various subgroups were calculated. CEDM sensitivity for the index lesion was 98.8% (322/326), which led to additional breast imaging in 23.6% (77/326) of patients and additional biopsies in 17.5% (57/326). CEDM changed the type of surgery in 18.4% (60/326). In the preoperative breast cancer staging, CEDM sensitivity, specificity, PPV, NPV, and accuracy produced results of 93%, 98%, 90%, 98%, and 97%, respectively. CEDM performance was better in patients with palpable lesions. CEDM has an excellent diagnostic performance in the presurgical staging of BC. Symptomatic patients with palpable lesions benefitted most from preoperative CEDM, with a statistically significant difference compared with nonpalpable.


Asunto(s)
Neoplasias de la Mama , Biopsia , Mama/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Medios de Contraste , Femenino , Humanos , Mamografía , Estudios Retrospectivos , Sensibilidad y Especificidad
5.
Breast J ; 25(5): 980-983, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31165520

RESUMEN

Imaging-guided Core Needle Biopsy (CNB) is a procedure for tissue sampling in case of suspicious findings, such as breast masses and abnormal lymph nodes. It provides definitive diagnosis with a high accuracy rate and generally with no significant complications. To our knowledge, this is the first case report to document a pseudoaneurysm of the axilla after CNB. An illustrative case and a diagnostic and therapeutic literature review are presented.


Asunto(s)
Aneurisma Falso/etiología , Axila/patología , Biopsia con Aguja Gruesa/efectos adversos , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/cirugía , Axila/diagnóstico por imagen , Axila/cirugía , Neoplasias de la Mama/patología , Angiografía por Tomografía Computarizada , Femenino , Humanos , Persona de Mediana Edad
6.
Radiol Med ; 122(9): 651-655, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28510806

RESUMEN

Primary breast lymphoma (PBL) may mimic carcinoma clinically and also mammographic and ecographic distinction is subtle. Despite its rarity, incidence of PBLs has increased over the last four decades and continues to increase for younger women and for some subtypes, and for this reason it is increasingly important to achieve a preoperative pathological diagnosis using core needle biopsy (CNB) or fine-needle aspiration cytology (FNA). The aim of this retrospective study was to report our single-center experience in CNBs performed for histological diagnosis of PBL compared to FNA. From a total of 10,500 CNBs we found seven patients affected by PBL diagnosed at Careggi Florence University Hospital, between January 2000 and December 2016. Diffuse large B cell lymphoma (DLBCL) was the most frequent PBLs and on CNBs specimens was possible do the fluorescent in situ hybridization analysis to evaluate the presence of chromosomal translocation. CNB is an effective method for the assessment of PBLs, especially for DLBCL, in which a correct and fast classification could change the therapeutic approach and the prognosis.


Asunto(s)
Biopsia con Aguja Fina , Biopsia con Aguja Gruesa , Neoplasias de la Mama/patología , Linfoma/patología , Ultrasonografía Intervencional , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Italia , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos
9.
Gland Surg ; 13(3): 297-306, 2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-38601291

RESUMEN

Background: Reconstructive options that can be used following conservative mastectomy, skin-, nipple-sparing and skin-reducing mastectomies, allow a remarkable variety of safe methods to restore the natural shape and aesthetics of the breast mound. In case of two-stage breast reconstruction, tissue expanders (TEs) are usually placed in a subpectoral position. The purpose of this retrospective cohort study is to evaluate the feasibility and safety of two-step reconstruction with TE in pre-pectoral position covered by acellular dermal matrix (ADM). Methods: Between March 2021 and May 2023, at the Azienda Ospedaliero Universitaria Careggi, University of Florence, 55 patients with BRCA 1/2 mutations or early breast cancer underwent conservative mastectomy with immediate pre-pectoral reconstruction using TE covered with ADM, followed by a second surgery with replacement of the expander with definitive prosthesis. Demographic, oncological, and histological data along with surgical complications were recorded. Results: A total of 64 conservative mastectomies were performed. In 2 patients (3.1%) complications were found that required reintervention and, in both cases, the TE had to be removed. Two patients developed hematoma and one patient developed seroma. Two patients showed wound dehiscence, both healed after conservative treatment and without implant exposure. No case of necrosis of the skin or nipple-areola complex has been observed, neither of capsular contracture. Capsule formed around TE was populated with cells and blood vessels and showed a thin area of synovial metaplasia. Conclusions: In selected cases it may be more cautious to perform a two-stage breast reconstruction after radical breast surgery by means of TEs. The placement of TEs in pre-pectoral position combines the excellent aesthetic and functional results of the pre-pectoral philosophy with a quite safer and more prudent two-step approach. Our experience reports optimistic results: the ADM covering the TE is seen successfully integrating during tissue expansion and becoming a vascularised new self-tissue. Complications rates are low and such ADM-assisted two-stage pre-pectoral reconstructive technique is a safe, practical, and reproducible method.

10.
Breast Cancer ; 2024 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-38811515

RESUMEN

BACKGROUND: To assess contrast-enhanced mammography (CEM) in the management of BI-RADS3 breast architectural distortions (AD) in digital breast tomosynthesis (DBT). METHODS: We retrospectively reviewed 328 women with 332 ADs detected on DBT between 2017 and 2021 and selected those classified as BI-RADS3 receiving CEM as problem-solving. In CEM recombined images, we evaluated AD's contrast enhancement (CE) according to its presence/absence, type, and size. AD with enhancement underwent imaging-guided biopsy while AD without enhancement follow-up or biopsy if detected in high/intermediate-risk women. RESULTS: AD with enhancement were 174 (52.4%): 72 (41.4%) were malignant lesions, 102 (59.6%) false positive results: 28 (16%) B3 lesions, and 74 (42.5%) benign lesions. AD without enhancement were 158 (47.6%): 26 (16.5%) were subjected to biopsy (1 malignant and 25 benign) while the other 132 cases were sent to imaging follow-up, still negative after two years. CEM's sensitivity, specificity, positive (PPV) and negative predictive values (NPV), and accuracy were 98.63%, 60.62%, 41.38%, 99.37%, and 68.98%. The AUC determined by ROC was 0.796 (95% CI, 0.749-0.844). CONCLUSION: CEM has high sensitivity and NPV in evaluating BI-RADS3 AD and can be a complementary tool in assessing AD, avoiding unnecessary biopsies without compromising cancer detection.

11.
Cancers (Basel) ; 15(13)2023 Jul 06.
Artículo en Inglés | MEDLINE | ID: mdl-37444630

RESUMEN

Breast lesions of uncertain malignant potential (B3) are frequently diagnosed in the era of breast cancer (BC) screening and their management is controversial. They are generally removed surgically, but some international organizations and guidelines for breast research suggest follow-up care alone or, more recently, propose vacuum-assisted excision (VAE). The risk of upgrade to BC is known, but very little data exist on its role as risk factor for future BC development. We analyzed 966 B3 lesions diagnosed at our institution, 731 of which had long-term follow-up available. Surgical removal was performed in 91%, VAE in 3.8%, and follow-up in 5.2% of cases. The B3 lesions included flat epithelial atypia (FEA), atypical ductal hyperplasia (ADH), lobular intraepithelial neoplasia (LIN), atypical papillary lesions (PLs), radial scars (RSs), and others. Overall, immediate upgrade to BC (invasive or in situ) was 22.7%. After long-term follow-up, 9.2% of the patients were diagnosed with BC in the same or contralateral breast. The highest risk was associated with ADH diagnosis, with 39.8% of patients upgraded and 13.6% with a future BC diagnosis (p < 0.0001). These data support the idea that B3 lesions should be removed and provide evidence to suggest annual screening mammography for women after a B3 diagnosis because their BC risk is considerably increased.

12.
Diagnostics (Basel) ; 13(6)2023 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-36980319

RESUMEN

(1) Purpose: The latest Breast Imaging Reporting and Data System (BI-RADS) lexicon for CEM introduced a new descriptor, enhancing asymmetries (EAs). The purpose of this study was to determine which types of lesions were correlated with EAs. (2) Methods: A total of 3359 CEM exams, executed at AOUC Careggi in Florence, Italy between 2019 and 2021 were retrospectively assessed by two radiologists. For each of the EAs found, the size, the enhancing conspicuity (degree of enhancement relative to background described as low, moderate, or high), whether there was a corresponding finding in the traditional radiology images (US or mammography), the biopsy results when performed including any follow-up exams, and the presence of background parenchymal enhancement (BPE) of the normal breast tissue (minimal, mild, moderate, marked) were described. (3) Results: A total of 64 women were included, 36 of them underwent CEM for a preoperative staging assessment, and 28 for a problem-solving examination. Among the 64 EAs, 19/64 (29.69%) resulted in being category B5 (B5) lesions, 5/64 (7.81%) as category B3 (B3) lesions, and 40/64(62.50%) were negative or benign either after biopsy or second-look exams or follow-up. We assessed that EAs with higher enhancing conspicuity correlated significantly with a higher risk of B5 lesions (p: 0.0071), especially bigger ones (p: 0.0274). Conclusions: EAs can relate both with benign and tumoral lesions, and they need to be assessed as the other CEM descriptors, with re-evaluation of low-energy images and second-look exams, particularly larger EAs with higher enhancing conspicuity.

13.
Br J Radiol ; 95(1134): 20210927, 2022 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-35451312

RESUMEN

OBJECTIVES: To compare second-look ultrasound (SL-ultrasound) with second-look digital breast tomosynthesis (SL-DBT) in the detection of additional lesions (ALs) with presurgical contrast-enhanced spectral mammography (CESM). METHODS: We retrospectively included 121 women with 128 ALs from patients who underwent CESM for presurgical staging at our centre from September 2016 to December 2018. These ALs underwent SL-ultrasound and a retrospective review of DBT (SL-DBT) performed 1-3 weeks prior to CESM to evaluate the performance of each technique individually and in combination. ALs in CESM images were evaluated according to enhancement type (focus, mass, or non-mass), size (<10 mm or >10 mm) and level of suspicion (BI-RADS 2, 3, 4 or 5). Our gold-standard was post-biopsy histology, post-surgical specimen or >24 month negative follow-up. McNemar's test was used for the statistical analysis. RESULTS: Out of the 128 ALs, an imaging correlate was found for 71 (55.5 %) with ultrasound, 79 (61.7%) with DBT, 53 (41.4 %) with DBT and ultrasound, and 97 (75.8%) with ultrasound and/or DBT. SL-DBT demonstrated a higher detection rate vs SL-ultrasound in non-mass enhancement (NME) pattern (p: 0.0325) and ductal carcinoma in situ histological type (p: 0.0081). Adding SL-DBT improved the performance vs SL-ultrasound alone in the overall sample (p: <0.0001) and in every subcategory identified; adding SL-ultrasound to SL-DBT improved the detectability of ALs in the overall sample and in every category except for NME (p: 0.0833), foci (p: 0.0833) and B3 lesions (p: 0.3173). CONCLUSION: Combined second-look imaging (SL-DBT+ SL-ultrasound) for CESM ALs is superior to SL-DBT alone and SL-ultrasound alone. In B3 lesions, NME, and foci, the analysis of a larger sample could determine whether adding SL-ultrasound to SL-DBT is necessary or not. ADVANCES IN KNOWLEDGE: Thanks to its high sensitivity, CESM is a useful tool in presurgical staging to detect the extent of the disease burden and identify ALs not detected with conventional imaging. Since CESM-guided biopsy systems are still scarcely available in clinical practice, it is necessary to look for other approaches to histologically characterize ALs detected with CESM. In our study, combined second-look imaging (SL-DBT + SL-ultrasound) showed better performance in terms of detectability of ALs, than either SL-DBT or SL-ultrasound alone, and allowed us to identify 91.2% of ALs that turned out to be malignant at final histology; for the remaining 8.8% it was still necessary to perform MRI or MRI-guided biopsy. However, this issue could be solved once CESM-guided biopsies spread in clinical practice. SL-DBT demonstrated a higher detection rate than SL-ultrasound in NME and ductal carcinoma in situ histology.


Asunto(s)
Neoplasias de la Mama , Carcinoma Intraductal no Infiltrante , Mama/patología , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Neoplasias de la Mama/cirugía , Carcinoma Intraductal no Infiltrante/patología , Femenino , Humanos , Biopsia Guiada por Imagen/métodos , Mamografía/métodos , Estudios Retrospectivos , Sensibilidad y Especificidad , Ultrasonografía Mamaria/métodos
14.
Acad Radiol ; 29(9): 1342-1349, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35065889

RESUMEN

RATIONALE AND OBJECTIVES: The aim of this retrospective study is to compare the radiation dose received during CEDM, short and long protocol (CEDM SP and CEDM LP), with dose received during DM and DBT on patients with varying breast thickness, age and density. MATERIALS AND METHODS: Between January 2019 and December 2019, patients having 6214 DM, 3662 DBT and 173 CEDM examinations in our department were analyzed. Protocol total single breast AGD has been evaluated for all clinical imaging protocols, extracting AGD values and exposure data from the dose DICOM Structured Report (SR) information stored in the hospital PACS system. Protocol AGD was calculated as the sum of single projection AGDs carried out in every exam for each clinical protocol. A total amount of 23,383 exams for each breast were analyzed. Protocol AGDs, stratified as a function of patient breast compression thickness, age, and breast density were assessed. RESULTS: The total protocol AGD median values for each protocol are: 2.8 mGy for DM, 3.2 mGy for DBT, 6.0 mGy for DM+DBT, 4.5 mGy for CEDM SP, 7.4 mGy for CEDM SP_DBT (CEDM SP protocol with DBT), 8.4 mGy for CEDM LP and 11.6 mGy for CEDM LP_DBT (CEDM LP protocol with DBT). CEDM SP AGD median value is 59% higher than DM AGD median value and 40% lesser than DM+DBT AGD median; this last difference was statistically confirmed with a p-value <0.001. AGD value for each standard breast CEDM SP projection results to be below 3-mGy limit. AGD value for each standard breast CEDM SP projection results to be below 3 mGy, as required by international legislation. For dense breasts, the AGD median value is 4.2 mGy, with the first and third quartile of 3.3 mGy and 6.0 mGy respectively; for non-dense breasts, the AGD median value is 4.7 mGy, with first and third quartile of 3.5 mGy and 6.3 mGy respectively. The difference between the two groups was statistically tested and confirmed, with a p-value of 0.039. CONCLUSION: CEDM SP results in higher radiation exposure compared with conventional DM and DBT but lower than the Combo mode. The dose administered during the CEDM SP is lower in patients with dense breasts regardless of their size. An interesting outcome, considering the ongoing studies on CEDM screening in patients with dense breasts.


Asunto(s)
Neoplasias de la Mama , Mamografía , Mama/diagnóstico por imagen , Densidad de la Mama , Neoplasias de la Mama/diagnóstico por imagen , Femenino , Humanos , Mamografía/métodos , Dosis de Radiación , Estudios Retrospectivos
15.
Clin Breast Cancer ; 22(1): 60-66, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34393050

RESUMEN

BACKGROUND: Selective pectoralis major muscle (PMM) denervation has been described in retro-pectoral reconstructions to obtain the advantages of the pre-pectoral approach. Present study compared subjective evaluations between retro-pectoral implant based breast reconstructions (IBBRs) with denervation to traditional techniques without denervation. METHODS: In 2020, two 2 groups of patients submitted to retro-pectoral IBBR, minimum 12-month follow-up, were compared through BREAST-Q post-operative questionnaire. Group-1 included direct-to-implant or two2-stage tissue expanderTE cases with selective PMM denervation, while Group-2 similar procedures, in the same time span 2017-2019, without denervation. BREAST-Q was divided into five 5 independent scales and for each scale item responses were summed up and transformed into a score, ranging from 0 to 100, to analyze and compare the results. RESULTS: 50 patients were included both in Group1 and Group-2. Group-1 patients reported significantly higher scores in "satisfaction with the reconstructed breast" scale compared to Group-2, means-medians of 56-58 and 47-50, respectively. A trend in favor of Group-1 was recorded in the scales of "psycho-social well-being", 64-65 vs. 58-53, and "sexual well-being", 53-47 vs. 48-47, albeit not significant. Substantial equivalence was found in "satisfaction with the result overall" and "physical well-being". CONCLUSION: PMM denervation can improve cosmetic results in retro-pec IBBRs, thus leading to better QoL. Possible pain and physical discomfort weren't caused by denervation with scores similar to non-denervated controls.


Asunto(s)
Neoplasias de la Mama/cirugía , Desnervación/métodos , Estética , Músculos Pectorales/inervación , Adulto , Implantación de Mama/métodos , Neoplasias de la Mama/patología , Femenino , Humanos , Mamoplastia/métodos , Persona de Mediana Edad , Satisfacción del Paciente , Músculos Pectorales/cirugía , Calidad de Vida , Resultado del Tratamiento
16.
Breast Cancer ; 29(2): 302-313, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34775540

RESUMEN

We re-evaluated acute and early-late toxicity-related factors among pre-pectoral immediate tissue expander/implant (TE/I) breast reconstruction (BR) unselected, first-era, cases, including previous breast radiation treatment and post-mastectomy radiation therapy (PMRT). A retrospective analysis of 146 (117 therapeutic and 29 prophylactic) pre-pectoral reconstructions, between 2012 and 2016, considered patient-related (age, body mass index [BMI], smoke-history, comorbidity, BRCA mutation), and treatment-related characteristics (previous irradiation, axillary surgery, PMRT, pre- and postoperative chemotherapy, endocrine therapy, and target-therapy). Safety was evaluated as acute and early-late complications, and TE/I failures. At multivariate analysis of the 146 cases (117 patients submitted to BR) a significant factor related to acute toxicity was: BMI ≥ 25 (31.3% [≥ 25] vs 8.8% [< 25]; OR 4.44, 95% CI 1.56-12.6; p = 0.003), while previous breast surgery on ipsilateral side presented a borderline significance (31.6% [previous surgery] vs 7.4% [no previous surgery]; OR 3.74, 95% CI 0.97-14.40; p = 0.055). Factors significantly related to TE/I failure were: current or previous smoking exposition (13.8% [smokers] vs 2.6% [non-smokers]; OR 7.32, 95% CI 1.37-39.08; p = 0.02) and preoperative chemotherapy (18.8% [yes] vs 3.5% [no]; OR 8.16, 95% CI 1.29-51.63; p = 0.026). At 4-year median follow-up, 3 deaths, 5 locoregional recurrences, and 14 distant metastases occurred. Immediate pre-pectoral BR is safe and effective, with low rates of acute and early-late complications. BMI and previous breast surgery were related to higher complications but not failure; smoking and preoperative chemotherapy were related to TE/I explant. Previous RT and PMRT were related neither to early-late toxicity nor failure.


Asunto(s)
Implantes de Mama , Neoplasias de la Mama , Mamoplastia , Implantes de Mama/efectos adversos , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/cirugía , Femenino , Humanos , Mamoplastia/efectos adversos , Mastectomía/efectos adversos , Recurrencia Local de Neoplasia/epidemiología , Recurrencia Local de Neoplasia/prevención & control , Complicaciones Posoperatorias/etiología , Radioterapia Adyuvante/efectos adversos , Estudios Retrospectivos , Dispositivos de Expansión Tisular/efectos adversos
17.
Artículo en Inglés | MEDLINE | ID: mdl-34063854

RESUMEN

Breast cancer (BC) is the cancer with the highest incidence in women in the world. In this last period, the COVID-19 pandemic has caused in many cases a drastic reduction of routine breast imaging activity due to the combination of various factors. The survival of BC is directly proportional to the earliness of diagnosis, and especially during this period, it is at least fundamental to remember that a diagnostic delay of even just three months could affect BC outcomes. In this article we will review the state of the art of breast imaging, starting from morphological imaging, i.e., mammography, tomosynthesis, ultrasound and magnetic resonance imaging and contrast-enhanced mammography, and their most recent evolutions; and ending with functional images, i.e., magnetic resonance imaging and contrast enhanced mammography.


Asunto(s)
Neoplasias de la Mama , COVID-19 , Neoplasias de la Mama/diagnóstico por imagen , Diagnóstico Tardío , Femenino , Humanos , Imagen por Resonancia Magnética , Mamografía , Pandemias , SARS-CoV-2
18.
Insights Imaging ; 11(1): 16, 2020 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-32034578

RESUMEN

Contrast-enhanced digital mammography (CEDM) is a diagnostic tool for breast cancer detection. Artefacts are observed in about 10% of CEDM examinations. Understanding CEDM artefacts is important to prevent diagnostic misinterpretation. In this article, we have described the artefacts that we have commonly encountered in clinical practice; we hope to ease the recognition and help troubleshoot solutions to prevent or minimise them.

19.
Breast ; 54: 15-24, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32889303

RESUMEN

BACKGROUND: CEDM has demonstrated a diagnostic performance similar to MRI and could have similar limitations in breast cancer (BC) detection. PURPOSE: The aim of our study was to systematically analyze the characteristics of the lesions with the absence of enhancement with CEDMs, called false-negatives (FNs), in order to identify which clinical, radiological, histological and molecular parameters are associated with the absence of enhancement of known BCs with CEDMs, and which types of BC are most likely to cause FNs in CEDMs. We also tried to evaluate which parameters instead increased the probability of showing enhancement in the same context. MATERIALS AND METHODS: Included in our study group were 348 women with 348 diagnosed BCs performing CEDM as preoperative staging. Two breast-imaging radiologists reviewed the CEDM exams. The absence of perceptible contrast enhancement at the index cancer site was indicative of an FN CEDM, whereas cases with appreciable enhancement were considered true positives (TPs). Dichotomic variables were analyzed with Fisher's exact probability test or, when applicable, the chi-square test. Binary logistic regression was performed on variables shown to be significant by the univariate analysis in order to assess the relationship between predictors (independent variables) and TFNs (outcome). RESULTS: Enhancement was observed in 317 (91.1%) of the 348 BCs. From the 31 (8.9%) lesions which were FNs, we excluded 12 (38.7%) which showed an artifact generated by the post biopsy hematoma and 6 (19.4%) which were outside the CEDM field of vision. We thus obtained 13 (41.9%) BCs considered "True False Negatives" (TFNs), i.e. BCs which showed no enhancement despite being within the CEDM field of vision and failed to show post biopsy hematoma artifacts. We found that the TFNs frequently have a unifocal disease extension, diameter <10 mm, a lower number of luminal B HER2-subtypes, a higher number of DCIS, and an index lesion with microcalcifications. CONCLUSIONS: The parameters we found to be associated with no enhancement of known BCs with CEDMs were: unifocal disease extension, DCIS histotype, lesion dimensions <10 mm, and index lesion with microcalcifications. The characteristics that instead increase the probability of showing enhancement were US mass, Luminal B HER2 negative molecular subtype, the presence of an invasive ductal component, and lesion dimensions ≥10 mm.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Medios de Contraste , Detección Precoz del Cáncer/estadística & datos numéricos , Mamografía/estadística & datos numéricos , Intensificación de Imagen Radiográfica , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores de Tumor/análisis , Biopsia/métodos , Mama/diagnóstico por imagen , Mama/patología , Neoplasias de la Mama/patología , Detección Precoz del Cáncer/métodos , Reacciones Falso Negativas , Femenino , Humanos , Modelos Logísticos , Mamografía/métodos , Persona de Mediana Edad , Estadificación de Neoplasias/métodos , Estudios Retrospectivos
20.
Tumori ; 105(5): 378-387, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30558495

RESUMEN

PURPOSE: To evaluate the role of contrast-enhanced spectral mammography (CESM) in the post biopsy management of breast lesions classified as lesions of uncertain malignant potential (B3) by core needle biopsy and vacuum-assisted biopsy (VAB). METHODS: The local ethics committee approved this retrospective study and for this type of study formal consent is not required. A total of 42 B3 lesions in 40 women aged 41-77 years were included in our study. All patients underwent CESM 2-3 weeks after the biopsy procedure and surgical excision was subsequently performed within 60 days of the CESM procedure. Three radiologists reviewed the images independently. The results were then compared with histologic findings. RESULTS: The sensitivity, specificity, and positive and negative predictive values for confirmed demonstration of malignancy at CESM were 33.3%, 87.2%, 16.7%, and 94.4% for reader 1; 66.7%, 76.9%, 18.2%, and 96.7% for reader 2; 66.7%, 74.4%, 16.7%, and 96.7% for reader 3. Overall agreement on detection of malignant lesions using CESM among readers ranged from moderate to substantial (κ = .451-.696), for categorization of BPE from moderate to substantial (κ = .562-.711), and for evaluation of lesion intensity enhancement from fair to moderate (κ = .346-.459). CONCLUSION: In cases of Breast Imaging Reporting and Data System (BI-RADS) 1, BI-RADS 2, or BI-RADS 3 results at CESM, follow-up or VAB rather than surgical biopsy might be performed.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Medios de Contraste/uso terapéutico , Detección Precoz del Cáncer , Mamografía , Adulto , Anciano , Biopsia con Aguja Gruesa , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Femenino , Humanos , Persona de Mediana Edad , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA