Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Circulation ; 145(5): 321-329, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34779221

RESUMEN

BACKGROUND: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) showed noninferiority of subcutaneous implantable cardioverter defibrillator (S-ICD) compared with transvenous implantable cardioverter defibrillator (TV-ICD) with regard to inappropriate shocks and complications. In contrast to TV-ICD, S-ICD cannot provide antitachycardia pacing for monomorphic ventricular tachycardia. This prespecified secondary analysis evaluates appropriate therapy and whether antitachycardia pacing reduces the number of appropriate shocks. METHODS: The PRAETORIAN trial was an international, investigator-initiated randomized trial that included patients with an indication for implantable cardioverter defibrillator (ICD) therapy. Patients with previous ventricular tachycardia <170 bpm or refractory recurrent monomorphic ventricular tachycardia were excluded. In 39 centers, 849 patients were randomized to receive an S-ICD (n=426) or TV-ICD (n=423) and were followed for a median of 49.1 months. ICD programming was mandated by protocol. Appropriate ICD therapy was defined as therapy for ventricular arrhythmias. Arrhythmias were classified as discrete episodes and storm episodes (≥3 episodes within 24 hours). Analyses were performed in the modified intention-to-treat population. RESULTS: In the S-ICD group, 86 of 426 patients received appropriate therapy, versus 78 of 423 patients in the TV-ICD group, during a median follow-up of 52 months (48-month Kaplan-Meier estimates 19.4% and 17.5%; P=0.45). In the S-ICD group, 83 patients received at least 1 shock, versus 57 patients in the TV-ICD group (48-month Kaplan-Meier estimates 19.2% and 11.5%; P=0.02). Patients in the S-ICD group had a total of 254 shocks, compared with 228 shocks in the TV-ICD group (P=0.68). First shock efficacy was 93.8% in the S-ICD group and 91.6% in the TV-ICD group (P=0.40). The first antitachycardia pacing attempt successfully terminated 46% of all monomorphic ventricular tachycardias, but accelerated the arrhythmia in 9.4%. Ten patients with S-ICD experienced 13 electrical storms, versus 18 patients with TV-ICD with 19 electrical storms. Patients with appropriate therapy had an almost 2-fold increased relative risk of electrical storms in the TV-ICD group compared with the S-ICD group (P=0.05). CONCLUSIONS: In this trial, no difference was observed in shock efficacy of S-ICD compared with TV-ICD. Although patients in the S-ICD group were more likely to receive an ICD shock, the total number of appropriate shocks was not different between the 2 groups. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01296022.


Asunto(s)
Arritmias Cardíacas/terapia , Desfibriladores Implantables/normas , Anciano , Arritmias Cardíacas/diagnóstico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
2.
N Engl J Med ; 383(6): 526-536, 2020 08 06.
Artículo en Inglés | MEDLINE | ID: mdl-32757521

RESUMEN

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) was designed to avoid complications related to the transvenous ICD lead by using an entirely extrathoracic placement. Evidence comparing these systems has been based primarily on observational studies. METHODS: We conducted a noninferiority trial in which patients with an indication for an ICD but no indication for pacing were assigned to receive a subcutaneous ICD or transvenous ICD. The primary end point was the composite of device-related complications and inappropriate shocks; the noninferiority margin for the upper boundary of the 95% confidence interval for the hazard ratio (subcutaneous ICD vs. transvenous ICD) was 1.45. A superiority analysis was prespecified if noninferiority was established. Secondary end points included death and appropriate shocks. RESULTS: A total of 849 patients (426 in the subcutaneous ICD group and 423 in the transvenous ICD group) were included in the analyses. At a median follow-up of 49.1 months, a primary end-point event occurred in 68 patients in the subcutaneous ICD group and in 68 patients in the transvenous ICD group (48-month Kaplan-Meier estimated cumulative incidence, 15.1% and 15.7%, respectively; hazard ratio, 0.99; 95% confidence interval [CI], 0.71 to 1.39; P = 0.01 for noninferiority; P = 0.95 for superiority). Device-related complications occurred in 31 patients in the subcutaneous ICD group and in 44 in the transvenous ICD group (hazard ratio, 0.69; 95% CI, 0.44 to 1.09); inappropriate shocks occurred in 41 and 29 patients, respectively (hazard ratio, 1.43; 95% CI, 0.89 to 2.30). Death occurred in 83 patients in the subcutaneous ICD group and in 68 in the transvenous ICD group (hazard ratio, 1.23; 95% CI, 0.89 to 1.70); appropriate shocks occurred in 83 and 57 patients, respectively (hazard ratio, 1.52; 95% CI, 1.08 to 2.12). CONCLUSIONS: In patients with an indication for an ICD but no indication for pacing, the subcutaneous ICD was noninferior to the transvenous ICD with respect to device-related complications and inappropriate shocks. (Funded by Boston Scientific; PRAETORIAN ClinicalTrials.gov number, NCT01296022.).


Asunto(s)
Arritmias Cardíacas/terapia , Desfibriladores Implantables/efectos adversos , Anciano , Cardiomiopatías/terapia , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/prevención & control , Electrodos Implantados/efectos adversos , Falla de Equipo , Femenino , Estudios de Seguimiento , Cardiopatías/terapia , Humanos , Incidencia , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Diseño de Prótesis
3.
Eur Heart J ; 43(47): 4872-4883, 2022 12 14.
Artículo en Inglés | MEDLINE | ID: mdl-36030464

RESUMEN

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is developed to overcome lead-related complications and systemic infections, inherent to transvenous ICD (TV-ICD) therapy. The PRAETORIAN trial demonstrated that the S-ICD is non-inferior to the TV-ICD with regard to the combined primary endpoint of inappropriate shocks and complications. This prespecified secondary analysis evaluates all complications in the PRAETORIAN trial. METHODS AND RESULTS: The PRAETORIAN trial is an international, multicentre, randomized trial in which 849 patients with an indication for ICD therapy were randomized to receive an S- ICD (N = 426) or TV-ICD (N = 423) and followed for a median of 49 months. Endpoints were device-related complications, lead-related complications, systemic infections, and the need for invasive interventions. Thirty-six device-related complications occurred in 31 patients in the S-ICD group of which bleedings were the most frequent. In the TV-ICD group, 49 complications occurred in 44 patients of which lead dysfunction was most frequent (HR: 0.69; P = 0.11). In both groups, half of all complications were within 30 days after implantation. Lead-related complications and systemic infections occurred significantly less in the S-ICD group compared with the TV-ICD group (P < 0.001, P = 0.03, respectively). Significantly more complications required invasive interventions in the TV-ICD group compared with the S-ICD group (8.3% vs. 4.3%, HR: 0.59; P = 0.047). CONCLUSION: This secondary analysis shows that lead-related complications and systemic infections are more prevalent in the TV-ICD group compared with the S-ICD group. In addition, complications in the TV-ICD group were more severe as they required significantly more invasive interventions. This data contributes to shared decision-making in clinical practice.


Asunto(s)
Muerte Súbita Cardíaca , Desfibriladores Implantables , Humanos , Resultado del Tratamiento , Desfibriladores Implantables/efectos adversos
4.
J Cardiovasc Electrophysiol ; 33(5): 885-896, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35257441

RESUMEN

INTRODUCTION: Approximately 18% of patients with atrial fibrillation (AF) undergo a repeat ablation within 12 months after their index ablation. Despite the high prevalence, comparative studies on nonpulmonary vein (PV) target strategies in repeat AF ablation are scarce. Here, we describe 12 months efficacy of non-PV and PV target ablations as a repeat ablation strategy. METHODS: A multicentre retrospective, descriptive study was conducted with data of 280 patients who underwent repeat AF ablation. The ablation strategy for repeat ablation was at the operators' discretion. Non-PV target ablation (n = 140) included PV reisolation, posterior wall isolation, mitral line, roofline, and/or complex fractionated atrial electrogram ablation. PV target ablation (n = 140), included reisolation and/or wide atrium circumferential ablation. Patients' demographics and rhythm outcomes during 12 months follow-up were analyzed. RESULTS: At 12 months, more atrial tachyarrhythmias were observed in the non-PV target group (48.6%) compared to the PV target group (29.3%, p = .001). Similarly, a significantly higher AF and atrial tachycardia (AT) recurrence rate was observed after non-PV target ablation compared to PV target ablation (36.4% vs. 22.1% and 22.9% vs. 10.7%). After adjustment, a significantly higher risk of AT recurrence remained in the non-PV target group. Both groups significantly de-escalated antiarrhythmic drug use; de-escalation was more profound after PV target ablation. Patients with isolated PVs during non-PV target ablation had a significantly higher risk for AF recurrence than those with reconnected PVs. CONCLUSION: Compared to PV target ablation, non-PV target repeat ablation did not improve outcomes after 12 months and was independently associated with an increased risk for AT recurrences.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Humanos , Venas Pulmonares/cirugía , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento
5.
J Cardiovasc Electrophysiol ; 33(3): 559-564, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35040534

RESUMEN

BACKGROUND: Persistent phrenic nerve palsy (PNP) is an established complication of atrial fibrillation (AF) ablation, especially during cryoballoon and thoracoscopic ablation. Data on persistent PNP reversibility is limited because most patients recover <24 h. This study aims to investigate persistent PNP recovery, freedom of PNP-related symptoms after AF ablation and identify baseline variables associated with the occurrence and early PNP recovery in a large nationwide registry study. METHODS: In this study, we used data from the Netherlands Heart Registration, comprising data from 9549 catheter and thoracoscopic AF ablations performed in 2016 and 2017. PNP data was available of 7433 procedures, and additional follow-up data were collected for patients who developed persistent PNP. RESULTS: Overall, the mean age was 62 ± 10 years, and 67.7% were male. Fifty-four (0.7%) patients developed persistent PNP and follow-up was available in 44 (81.5%) patients. PNP incidence was 0.07%, 0.29%, 1.41%, and 1.25%, respectively for patients treated with conventional-RF, phased-RF, cryoballoon, and thoracoscopic ablation respectively. Seventy-one percent of the patients fully recovered, and 86% were free of PNP-related symptoms after a median follow-up of 203 (113-351) and 184 (82-359) days, respectively. Female sex, cryoballoon, and thoracoscopic ablation were associated with a higher risk to develop PNP. Patients with PNP recovering ≤180 days had a larger left atrium volume index than those with late or no recovery. CONCLUSION: After AF ablation, persistent PNP recovers in the majority of patients, and most are free of symptoms. Female patients and patients treated with cryoballoon or thoracoscopic ablation are more prone to develop PNP.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Criocirugía/efectos adversos , Criocirugía/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Países Bajos/epidemiología , Parálisis/etiología , Nervio Frénico , Venas Pulmonares/cirugía , Resultado del Tratamiento
6.
J Electrocardiol ; 66: 33-37, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33725506

RESUMEN

Single­lead electrocardiograms (1 L-ECGs) are increasingly used in (pre)clinical settings for the detection and monitoring of a range of rhythm and conduction disorders. In this short communication paper, we aim to provide an overview of the usefulness and potential pitfalls when implementing 1 L-ECGs into everyday clinical practice. Moreover, we provide recommendations for improving signal quality, as well as a systematic approach to the interpretation of 1 L-ECGs, which is somewhat different from standard 12­lead ECGs. Clinicians can use our illustrations and checklist as guidance when recording and interpreting 1 L-ECGs.


Asunto(s)
Electrocardiografía , Humanos
7.
Cardiology ; 145(12): 795-801, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32841937

RESUMEN

BACKGROUND: Symptomatic idiopathic ventricular arrhythmias (VA), including premature beats (VPB) and nonsustained ventricular tachycardia (VT) are commonly encountered arrhythmias. Although these VA are usually benign, their treatment can be a challenge to primary and secondary health care providers. Mainstay treatment is comprised of antiarrhythmic drugs (AAD) and, in case of drug intolerance or failure, patients are referred for catheter ablation to tertiary health care centers. These patients require extensive medical attention and drug regimens usually have disappointing results. A direct comparison between the efficacy of the most potent AAD and primary catheter ablation in these patients is lacking. The ECTOPIA trial will evaluate the efficacy of 2 pharmacological strategies and 1 interventional approach to: suppress the VA burden, improve the quality of life (QoL), and safety. HYPOTHESIS: We hypothesize that flecainide/verapamil combination and catheter ablation are both superior to sotalol in suppressing VA in patients with symptomatic idiopathic VA. STUDY DESIGN: The Elimination of Ventricular Premature Beats with Catheter Ablation versus Optimal Antiarrhythmic Drug Treatment (ECTOPIA) trial is a randomized, multicenter, prospective clinical trial to compare the efficacy of catheter ablation versus optimal AAD treatment with sotalol or flecainide/verapamil. One hundred eighty patients with frequent symptomatic VA in the absence of structural heart disease or underlying cardiac ischemia who are eligible for catheter ablation with an identifiable monomorphic VA origin with a burden ≥5% on 24-h ambulatory rhythm monitoring will be included. Patients will be randomized in a 1:1:1 fashion. The primary endpoint is defined as >80% reduction of the VA burden on 24-h ambulatory Holter monitoring. After reaching the primary endpoint, patients randomized to one of the 2 AAD arms will undergo a cross-over to the other AAD treatment arm to explore differences in drug efficacy and QoL in individual patients. Due to the use of different AAD (with and without ß-blocking characteristics) we will be able to explore the influence of alterations in sympathetic tone on VA burden reduction in different subgroups. Finally, this study will assess the safety of treatment with 2 different AAD and ablation of VA.


Asunto(s)
Antiarrítmicos , Ablación por Catéter , Flecainida , Sotalol , Taquicardia Ventricular , Verapamilo , Antiarrítmicos/uso terapéutico , Complejos Cardíacos Prematuros/tratamiento farmacológico , Complejos Cardíacos Prematuros/cirugía , Flecainida/uso terapéutico , Humanos , Estudios Prospectivos , Calidad de Vida , Sotalol/uso terapéutico , Taquicardia Ventricular/cirugía , Resultado del Tratamiento , Verapamilo/uso terapéutico
8.
Circulation ; 138(21): 2345-2358, 2018 11 20.
Artículo en Inglés | MEDLINE | ID: mdl-30571576

RESUMEN

BACKGROUND: Long QT syndrome (LQTS) is associated with potentially fatal arrhythmias. Treatment is very effective, but its diagnosis may be challenging. Importantly, different methods are used to assess the QT interval, which makes its recognition difficult. QT experts advocate manual measurements with the tangent or threshold method. However, differences between these methods and their performance in LQTS diagnosis have not been established. We aimed to assess similarities and differences between these 2 methods for QT interval analysis to aid in accurate QT assessment for LQTS. METHODS: Patients with a confirmed pathogenic variant in KCNQ1(LQT1), KCNH2(LQT2), or SCN5A(LQT3) genes and their family members were included. Genotype-positive patients were identified as LQTS cases and genotype-negative family members as controls. ECGs were analyzed with both methods, providing inter- and intrareader validity and diagnostic accuracy. Cutoff values based on control population's 95th and 99th percentiles, and LQTS-patients' 1st and 5th percentiles were established based on the method to correct for heart rate, age, and sex. RESULTS: We included 1484 individuals from 265 families, aged 33±21 years and 55% females. In the total cohort, QTTangent was 10.4 ms shorter compared with QTThreshold (95% limits of agreement±20.5 ms, P<0.0001). For all genotypes, QTTangent was shorter than QTThreshold ( P<0.0001), but this was less pronounced in LQT2. Both methods yielded a high inter- and intrareader validity (intraclass correlation coefficient >0.96), and a high diagnostic accuracy (area under the curve >0.84). Using the current guideline cutoff (QTc interval 480 ms), both methods had similar specificity but yielded a different sensitivity. QTc interval cutoff values of QTTangent were lower compared with QTThreshold and different depending on the correction for heart rate, age, and sex. CONCLUSION: The QT interval varies depending on the method used for its assessment, yet both methods have a high validity and can both be used in diagnosing LQTS. However, for diagnostic purposes current guideline cutoff values yield different results for these 2 methods and could result in inappropriate reassurance or treatment. Adjusted cutoff values are therefore specified for method, correction formula, age, and sex. In addition, a freely accessible online probability calculator for LQTS ( www.QTcalculator.org ) has been made available as an aid in the interpretation of the QT interval.


Asunto(s)
Electrocardiografía , Síndrome de QT Prolongado/diagnóstico , Adolescente , Adulto , Factores de Edad , Estudios de Casos y Controles , Niño , Bases de Datos Factuales , Canal de Potasio ERG1/genética , Femenino , Genotipo , Humanos , Canal de Potasio KCNQ1/genética , Síndrome de QT Prolongado/patología , Masculino , Persona de Mediana Edad , Canal de Sodio Activado por Voltaje NAV1.5/genética , Estudios Retrospectivos , Factores Sexuales , Adulto Joven
10.
Platelets ; 25(1): 71-4, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-23301869

RESUMEN

Early ischemic ventricular fibrillation (VF) in the setting of an acute myocardial infarction (AMI) due to thrombotic coronary occlusion remains a major health problem. Several animal studies have shown that platelet-dense granule contents released during thrombus formation can induce arrhythmias. We hypothesize that the platelet release reaction is involved in the predisposition to early ischemic VF. A case-control study was performed in patients who survived VF during a first AMI ("cases," n = 26) and in patients with one previous AMI without arrhythmias ("controls," n = 24). All patients were on aspirin 100 mg OD. Baseline platelet activation was assessed with flow cytometry. Response to activation was assessed with aggregometry, flow cytometry and PFA-100 analysis. Differences in platelet contents and content release were assessed by labeling platelet-dense granules with mepacrine and by measuring serotonin and ADP/ATP content. Patient and infarct characteristics and baseline platelet function tests were similar between groups. The mean time from event was 4.9 (±3.2) years among cases and 4.7 (±2.7) years among controls. Dense granule release was similar in cases versus controls. Platelet serotonin content in cases was higher than in controls (611 ± 118 ng/10E(9) platelets vs. 536 ± 141 ng/10(9), p = 0.048). Even years after the event, elevations in the platelet dense granule contents between VF survivors and controls may be detected. These preliminary findings shed new light on the pathophysiological mechanisms underlying ischemic VF, as platelet-dense granules may contain mediators of early ischemic VF risk.


Asunto(s)
Plaquetas/patología , Fibrilación Ventricular/sangre , Anciano , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sobrevivientes , Fibrilación Ventricular/patología
11.
Curr Probl Cardiol ; 49(1 Pt B): 102097, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37739276

RESUMEN

Artificial intelligence (AI) is already widely used in different fields of medicine, making possible the integration of the paraclinical exams with the clinical findings in patients, for a more accurate and rapid diagnosis and treatment decision. The electrocardiogram remains one of the most important, fastest, cheapest, and noninvasive methods of diagnosis in cardiology, despite the rapid development and progression of the technology. Even if studied a long time ago, it still has a lot of less understood features that, with a better understanding, can give more clues to a correct and prompt diagnosis in a short time. The use of AI in the interpretation of the ECG improved the accuracy and the time to diagnosis in different cardiovascular diseases, and more than this, explaining the decision to make AI diagnosis improved the human understanding of the different features of the ECG that might be considered for a more accurate diagnosis. The purpose of this article is to provide an overview of the most recently published articles about the use of AI in ECG interpretation.


Asunto(s)
Cardiología , Enfermedades Cardiovasculares , Humanos , Inteligencia Artificial , Aprendizaje Automático , Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/terapia , Electrocardiografía
12.
Prim Health Care Res Dev ; 25: e18, 2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38634311

RESUMEN

AIM: To evaluate the use of a single-lead electrocardiography (1L-ECG) device and digital cardiologist consultation platform in diagnosing arrhythmias among general practitioners (GPs). BACKGROUND: Handheld 1L-ECG offers a user-friendly alternative to conventional 12-lead ECG in primary care. While GPs can safely rule out arrhythmias on 1L-ECG recordings, expert consultation is required to confirm suspected arrhythmias. Little is known about GPs' experiences with both a 1L-ECG device and digital consultation platform for daily practice. METHODS: We used two distinct methods in this study. First, in an observational study, we collected and described all cases shared by GPs within a digital cardiologist consultation platform initiated by a local GP cooperative. This GP cooperative distributed KardiaMobile 1L-ECG devices among all affiliated GPs (n = 203) and invited them to this consultation platform. In the second part, we used an online questionnaire to evaluate the experiences of these GPs using the KardiaMobile and consultation platform. FINDINGS: In total, 98 (48%) GPs participated in this project, of whom 48 (49%) shared 156 cases. The expert panel was able to provide a definitive rhythm interpretation in 130 (83.3%) shared cases and answered in a median of 4 min (IQR: 2-18). GPs responding to the questionnaire (n = 43; 44%) thought the KardiaMobile was of added value for rhythm diagnostics in primary care (n = 42; 98%) and easy to use (n = 41; 95%). Most GPs (n = 36; 84%) valued the feedback from the cardiologists in the consultation platform. GPs experienced this project to have a positive impact on both the quality of care and diagnostic efficiency for patients with (suspected) cardiac arrhythmias. Although we lack a comprehensive picture of experienced impediments by GPs, solving technical issues was mentioned to be helpful for further implementation. More research is needed to explore reasons of GPs not motivated using these tools and to assess real-life clinical impact.


Asunto(s)
Cardiólogos , Médicos Generales , Humanos , Países Bajos , Derivación y Consulta , Electrocardiografía/métodos
13.
JACC Clin Electrophysiol ; 10(6): 1021-1033, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38613545

RESUMEN

BACKGROUND: INSTANT (INhalation of flecainide to convert recent-onset SympTomatic Atrial fibrillatioN to sinus rhyThm) was a multicenter, open-label, single-arm study of flecainide acetate oral inhalation solution (FlecIH) for acute conversion of recent-onset (≤48 hours) symptomatic atrial fibrillation (AF) to sinus rhythm. OBJECTIVES: This study investigated the efficacy and safety in 98 patients receiving a single dose of FlecIH delivered via oral inhalation. METHODS: Patients self-administered FlecIH over 8 minutes in a supervised medical setting using a breath-actuated nebulizer and were continuously monitored for 90 minutes using a 12-lead Holter. RESULTS: Mean age was 60.5 years, mean body mass index was 27.0 kg/m2, and 34.7% of the patients were women. All patients had ≥1 AF-related symptoms at baseline, and 87.8% had AF symptoms for ≤24 hours. The conversion rate was 42.6% (95% CI: 33.0%-52.6%) with a median time to conversion of 14.6 minutes. The conversion rate was 46.9% (95% CI: 36.4%-57.7%) in a subpopulation that excluded predose flecainide exposure for the current AF episode. Median time to discharge among patients who converted was 2.5 hours, and only 2 patients had experienced AF recurrence by day 5. In the conversion-no group, 44 (81.5%) patients underwent electrical cardioversion by day 5. The most common adverse events were related to oral inhalation of flecainide (eg, cough, oropharyngeal irritation/pain), which were mostly of mild intensity and limited duration. CONCLUSIONS: The risk-benefit of orally inhaled FlecIH for acute cardioversion of recent-onset AF appears favorable. FlecIH could provide a safe, effective, and convenient first-line therapeutic option. (INhalation of Flecainide to Convert Recent Onset SympTomatic Atrial Fibrillation to siNus rhyThm [INSTANT]; NCT03539302).


Asunto(s)
Antiarrítmicos , Fibrilación Atrial , Flecainida , Humanos , Fibrilación Atrial/tratamiento farmacológico , Femenino , Masculino , Flecainida/administración & dosificación , Persona de Mediana Edad , Anciano , Antiarrítmicos/administración & dosificación , Administración por Inhalación , Administración Oral , Resultado del Tratamiento
14.
Heart Rhythm ; 21(6): 836-844, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38336193

RESUMEN

BACKGROUND: The PRAETORIAN score estimates the risk of failure of subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy by using generator and lead positioning on bidirectional chest radiographs. The PRospective randomized compArative trial of subcutanEous implanTable cardiOverter-defibrillatoR ImplANtation with and without DeFibrillation Testing (PRAETORIAN-DFT) investigates whether PRAETORIAN score calculation is noninferior to defibrillation testing (DFT) with regard to first shock efficacy in spontaneous events. OBJECTIVE: This prespecified subanalysis assessed the predictive value of the PRAETORIAN score for defibrillation success in induced ventricular arrhythmias. METHODS: This multicenter investigator-initiated trial randomized 965 patients between DFT and PRAETORIAN score calculation after de novo S-ICD implantation. Successful DFT was defined as conversion of induced ventricular arrhythmia in <5 seconds from shock delivery within 2 attempts. Bidirectional chest radiographs were obtained after implantation. The predictive value of the PRAETORIAN score for DFT success was calculated for patients in the DFT arm. RESULTS: In total, 482 patients were randomized to undergo DFT. Of these patients, 457 (95%) underwent DFT according to protocol, of whom 445 (97%) had successful DFT and 12 (3%) had failed DFT. A PRAETORIAN score of ≥90 had a positive predictive value of 25% for failed DFT, and a PRAETORIAN score of <90 had a negative predictive value of 99% for successful DFT. A PRAETORIAN score of ≥90 was the strongest independent predictor for failed DFT (odds ratio 33.77; confidence interval 6.13-279.95; P < .001). CONCLUSION: A PRAETORIAN score of <90 serves as a reliable indicator for DFT success in patients with S-ICD, and a PRAETORIAN score of ≥90 is a strong predictor for DFT failure.


Asunto(s)
Desfibriladores Implantables , Cardioversión Eléctrica , Valor Predictivo de las Pruebas , Humanos , Femenino , Masculino , Persona de Mediana Edad , Cardioversión Eléctrica/métodos , Estudios Prospectivos , Anciano , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/etiología , Medición de Riesgo/métodos , Taquicardia Ventricular/terapia , Taquicardia Ventricular/fisiopatología , Fibrilación Ventricular/terapia
15.
Europace ; 15(7): 1042-9, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23533266

RESUMEN

AIMS: We sought to obtain insights into the efficacy of two websites, www.QTdrugs.org and www.BrugadaDrugs.org, that have the intention to prevent fatal arrhythmias due to unsafe drug use in Long QT syndrome and Brugada syndrome. METHODS AND RESULTS: Prospective web-use statistical analysis combined with online surveys were employed. Our main outcome measure was the percentage of Long QT syndrome patients and Brugada syndrome patients reporting refraining or discontinuation of possible unsafe drugs. QTdrugs.org has received >3 100 000 visitors from 180 countries. Most visitors originated from the Americas (87%), as compared with Europe (7%), Asia (3%), Oceania (2%), and Africa (1%). The QTdrugs.org survey yielded 340 respondents: 34% were patients and 50% medical professionals. Of the patients, 79% reported that they refrained from, and 61% reported discontinuing drugs due to the website. The website was very much appreciated by 65% of the respondents and 30% found it rather helpful. The BrugadaDrugs.org received >48 000 visitors from 154 countries. Most visitors originated from Europe (46%) and the Americas (39%), but less from Asia (10%), Oceania (4%), and Africa (<1%). The BrugadaDrugs.org survey yielded 178 respondents: 68% were patients and 21% medical professionals. Of the patients, 72% reported refraining from, and 48% discontinuing drugs due to the website. The website was very much appreciated by 72% of the respondents and 25% found it rather helpful. CONCLUSION: These websites are extensively used, they promote drug awareness, and they help patients to avoid possible pro-arrhythmic drugs. Visitors find the websites valuable but should note their limitations.


Asunto(s)
Síndrome de Brugada/prevención & control , Muerte Súbita Cardíaca/prevención & control , Servicios de Información sobre Medicamentos/estadística & datos numéricos , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos/prevención & control , Internet/estadística & datos numéricos , Síndrome de QT Prolongado/prevención & control , Adulto , Síndrome de Brugada/inducido químicamente , Síndrome de Brugada/mortalidad , Muerte Súbita Cardíaca/etiología , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos/etiología , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos/mortalidad , Femenino , Conocimientos, Actitudes y Práctica en Salud , Humanos , Síndrome de QT Prolongado/inducido químicamente , Síndrome de QT Prolongado/mortalidad , Masculino , Persona de Mediana Edad , Educación del Paciente como Asunto , Estudios Prospectivos , Factores de Riesgo , Encuestas y Cuestionarios , Resultado del Tratamiento
16.
Ned Tijdschr Geneeskd ; 1672023 09 18.
Artículo en Holandés | MEDLINE | ID: mdl-37742120

RESUMEN

A recent study in NEJM (DOSE-VF) showed that administering two consecutive defibrillation shocks with two separate defibrillators improves outcomes for patients with out-of-hospital cardiac arrest (OHCA). This approach was used when a shockable rhythm persisted after three standard shocks, raising the question of new strategies to improve survival for patients with persistent ventricular fibrillation (VF). In the Netherlands, there are around 8,000 OHCA cases annually, with 49% attributed to shockable rhythms. Prompt defibrillation is crucial, but some patients do not respond effectively to it. They may experience rapid VF recurrence or refractory VF, both associated with reduced survival rates. The current European resuscitation protocol emphasizes high-quality chest compressions, early defibrillation, and addressing reversible causes. The DOSE-VF study demonstrated the effectiveness of double sequential external defibrillation (DSED) in improving survival, spontaneous circulation, and neurological outcomes. Techniques such as changing pad positions, increasing initial shock energy, and pad compression can enhance energy transfer. However, implementing double sequential shocks in practice is challenging, requiring two separate defibrillators. The limited effect of this intervention may not warrant changes to extensively trained resuscitation protocols.


Asunto(s)
Paro Cardíaco Extrahospitalario , Fibrilación Ventricular , Humanos , Fibrilación Ventricular/terapia , Países Bajos , Paro Cardíaco Extrahospitalario/terapia , Resucitación , Tórax
17.
Artículo en Inglés | MEDLINE | ID: mdl-37897538

RESUMEN

BACKGROUND AND AIMS: One third of patients with atrial fibrillation (AF) suffer from high levels of anxiety and depression, which may significantly impair quality of life (QoL). The purpose of this study was to assess whether depressive and anxiety symptoms before ablation affect the QoL in patients with AF one year after cryoballoon ablation (CBA). METHODS: This single-center retrospective study investigated whether the AF patients with a high Hospital Anxiety and Depression Scale (HADS) score (≥ 8) had worse outcomes than patients with a low pre-ablation HADS score (< 8). The primary outcome was the difference in post-ablation QoL, and the secondary outcome included the difference in pre-ablative QoL, QoL improvement, and self-reported AF. RESULTS: Two hundred ninety-five patients were stratified according to their HADS scores (total, depression, and anxiety). Patients with an elevated HADS total, depression, or anxiety score (≥ 8), had a significantly lower QoL before and 12 months after CBA than patients with a HADS score < 8 (p-value < 0.001 for all groups). All groups improved significantly in QoL after CBA ablation and to a similar extent. Sixty-three percent of the patients reported AF symptoms after the procedure, which was comparable between the cohorts of patients. CONCLUSION: Patients with elevated HADS scores reported a lower QoL compared to participants with low HADS scores at baseline and 12 months after CBA. However, both groups improved in QoL after CBA, irrespective of their depressive and anxiety symptoms.

18.
J Clin Med ; 12(7)2023 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-37048733

RESUMEN

INTRODUCTION: Atrial fibrillation (AF) is more prevalent in men than in women. However, women with AF are more symptomatic, have a worse quality of life, a higher stroke risk and may therefore benefit most from ablation. In this study we aim to identify the risk of recurrent AF after thoracoscopic ablation, and assess the differential impact of the risk factors for recurrence between women and men. METHOD: This is a single center cohort study, including patients undergoing thoracoscopic ablation for advanced AF between 2008 and 2019. All patients were clinically followed up for two years with quarterly 24 h Holter monitoring and ECGs for the detection of recurrent AF. Left atrial appendage (LAA) tissue was collected for collagen analysis. RESULTS: We included 571 patients, of whom 143 (25%) were women. Women were older than men (63 ± 8.3 y vs. 59 ± 8.5, p < 0.001), but had fewer cardiovascular risk factors, myocardial infarctions (1.4% vs. 6.5%, p = 0.03) and, in particular, vascular disease (7.0% vs. 16.1%, p = 0.01). Women suffered more from AF recurrence, driven by more atrial tachycardias, and sex was an independent risk factor for recurrence (HR1.41 [1.04-1.91], p = 0.028]). The presence of vascular disease was associated with an increased risk for AF recurrence in women, but not in men. In LAA histology, women had more collagen than men, as had patients with persistent compared to paroxysmal AF. CONCLUSION: Women had 15% more recurrences, driven by more atrial tachycardias, which may be explained by a more fibrotic atrial substrate. What's new? Women undergoing thoracoscopic AF ablation have a higher risk of recurrent AF, driven by more atrial tachycardias. Among patients with left atrial enlargement or persistent AF, women have worse outcomes than men. Vascular disease was a risk factor for recurrence in women, but not in men. In a histopathologic analysis of the left atrial appendage, women had more collagen than men, as had patients with persistent compared to paroxysmal AF.

19.
PLoS One ; 17(1): e0261841, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35061716

RESUMEN

BACKGROUND: Clinical outcome of pulmonary vein isolation (PVI) has been predominantly focused on the reoccurrence of atrial fibrillation (AF) and the maintenance of sinus rhythm. However, there has been a limited intermediate follow-up on health-related quality-of-life (HRQoL) of patients. Given the relatively high recurrence rate of persistent AF after PVI treatment, it is important to follow up with clinical outcomes on symptom improvement as well as health-related quality-of-life. This study was designed to investigate the recurrence rate of atrial tachyarrhythmia (ATa), AF-related symptoms and HRQoL after PVI in patients with persistent AF who were treated with the second generation cryoballoon. METHODS: Total 148 patients participated in the study who were treated by PVI between 2013 and 2017 for persistent AF. All patients visited the out-patient clinic 2-5 years after PVI. During this visit all patients filled-out an AF Effect on Quality-of-life (AFEQT) questionnaire and a seven-day Holter was applied. All rhythm recordings acquired post ablation were collected and analysed, and the modified European Heart Rhythm Association score (mEHRA) scores were calculated before and after the ablation. RESULTS: The average age of patients was 63±9 year old and 44 (27.9%) were female. Mean CHA2DS2 VASc score was 1.9±1.4, and moderate and severe left atrial (LA) dilation was present in 53 (36.1%) and 15 (10.2%) patients, respectively. After a follow-up of 3.7±1.0 years, 81 (54.7%) patients had an ATa recurrence and 35 (23.6%) patients underwent a repeat LA ablation. However, the mEHRA score significantly improved in 80.4% of the patients (p <0.001), with the median overall AFEQT score of 88.9 [70.4-97.2]. CONCLUSIONS: There is a considerable ATa recurrence rate after PVI of persistent AF at intermediate-term follow-up. However, our data indicate that PVI significantly improved AF-related symptoms and resulted in a high HRQoL for 2-5 years in patients with persistent AF.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Criocirugía , Sistema de Conducción Cardíaco/cirugía , Calidad de Vida , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad
20.
J Interv Card Electrophysiol ; 64(2): 469-478, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34529207

RESUMEN

PURPOSE: Efficacy of pulmonary vein isolation (PVI) for atrial fibrillation (AF) decreases as left atrial (LA) volume increases. However, surgical AF ablation with unknown efficacy is being performed in patients with a giant LA (GLA). We determined efficacy of thoracoscopic AF ablation in patients with compared to without a GLA. METHODS: Patients underwent thoracoscopic PVI with additional left atrial ablations lines (in persistent AF) and were prospectively followed up. GLA was defined as LA volume index (LAVI) ≥ 50 ml/m2. Follow-up was performed with ECGs and 24-h Holters every 3 months. After a 3-month blanking period, all antiarrhythmic drugs were discontinued. The primary outcome was freedom of any atrial tachyarrhythmia ≥ 30 s during 2 years of follow-up. RESULTS: At baseline, 68 (15.4%) patients had a GLA (LAVI: 56.7 [52.4-62.8] ml/m2), while 374 (84.6%) had a smaller LA (LAVI: 34.8 [29.2-41.3] ml/m2). GLA patients were older (61.9 ± 6.9 vs 59.4 ± 8.8 years, p = 0.02), more often diagnosed with persistent AF (76.5% vs 58.6%, p = 0.008). Sex was equally distributed (with approximately 25% females). GLA patients had more recurrences compared to non-GLA patients at 2-year follow-up (42.6% vs 57.2%, log rank p = 0.02). Freedom of AF was 69.0% in non-GLA paroxysmal AF patients compared to 43.8-49.3% in a combined group of GLA and/or persistent AF patients(log rank p < 0.001). Furthermore, freedom was 62.4% in non-GLA male patients, compared to 43.8-47.4 in a combined group of GLA and/or female sex(log rank p = 0.02). CONCLUSION: Thoracoscopic AF ablation is an effective therapy in a substantial part of GLA patients. Thoracoscopic AF ablation may serve as a last resort treatment option in these patients.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Ablación por Catéter/efectos adversos , Femenino , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Humanos , Masculino , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA