Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 183
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-16513414

RESUMEN

An exploratory analysis was performed in order to evaluate the feasibility of building of neural network (NN) systems automating the identification of amphetamines necessary in the investigation of drugs of abuse for epidemiological, clinical and forensic purposes. A first neural network system was built to distinguish between amphetamines and nonamphetamines. A second, more refined system, aimed to the recognition of amphetamines according to their toxicological activity (stimulant amphetamines, hallucinogenic amphetamines, nonamphetamines). Both systems proved that discrimination between amphetamines and nonamphetamines, as well as between stimulants, hallucinogens and nonamphetamines is possible (83.44% and 85.71% correct classification rate, respectively). The spectroscopic interpretation of the 40 most important input variables (GC-FTIR absorption intensities) shows that the modeling power of an input variable seems to be correlated with the stability and not with the intensity of the spectral interaction. Thus, discarding variables only because they correspond to spectral windows with weak absorptions does not seem be not advisable.


Asunto(s)
Anfetaminas/análisis , Estimulantes del Sistema Nervioso Central/análisis , Redes Neurales de la Computación , Cromatografía de Gases/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectroscopía Infrarroja por Transformada de Fourier/métodos
2.
J Am Soc Mass Spectrom ; 6(4): 264-76, 1995 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24214172

RESUMEN

We investigated the potential of perfluoroacylation for gas chromatographic mass spectrometric determination of corticosteroids and related substances. Structure elucidation of the reaction products was performed with high and low resolution mass spectrometry and with proton and carbon nuclear magnetic resonance spectrometry. Besides the well known 3-enol ester formation, 17ß-methyl-18-nor-13(14)-ene steroids were formed via loss of the 17-α hydroxyl group followed by a Wagner-Meerwein rearrangement. Compounds that bear an 11ß-hydroxy group formed additionally a 9(11) double bond when acetone was used as solvent, whereas acetonitrile or cyclohexane led to formation of 11ß-perfluoroacyl esters. In particular, perfluoroacylation of cortisol led to a clearly defined product instead of complex mixtures observed before, which thus makes it a valuable alternative to methoxime formation-silylation of cortisol for quantitative gas chromatographic mass spectrometric analyses.

3.
Addiction ; 98(10): 1427-32, 2003 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-14519180

RESUMEN

AIMS: This study evaluates the suitability of gas chromatographic-mass spectrometric (GC-MS) analysis to follow-up the extent of benzodiazepine (mis)use in a Belgian prison population and compares it to other analytical strategies (e.g. screening followed by confirmation of the positive samples). DESIGN AND PARTICIPANTS: From February to August 1998, 598 persons were jailed of which 188 (31.4% of the incoming detainees) volunteered to be screened. Urine samples (530 in total) were collected on the day of arrival and after 14, 30 and 90 days of imprisonment. MEASUREMENTS: All samples were screened by EMIT(R) for benzodiazepines and analysed subsequently by GC-MS. FINDINGS: EMIT(R) screening yielded 117 (22.1%) positive samples, a number which increased to 174 (32.8%) after GC-MS analysis. Of these 174 GC-MS positive samples, 119 (68.4%) contained one benzodiazepine while for the remaining samples multiple benzodiazepine (mis)use could be demonstrated. A significant increase in benzodiazepine (mis)use was indicated only from day 0 to day 14 based on the GC-MS results but not on the immunoassay results, even when the latter were complemented with GC-MS analysis of the positively screened samples. The GC-MS data also demonstrated that benzodiazepines are mainly (mis)used by subjects on benzodiazepine prescription as almost 50% of these subjects took additional non-prescribed benzodiazepines. During GC-MS analysis other drugs were co-extracted unintentionally and chromatographed and 23.9% of the volunteers were positive for illegal drugs on the day of arrival. CONCLUSION: Immunoassay results yield an underestimation of the problem of benzodiazepine (mis)use in prison due to the high false negative rate. GC-MS analysis of all samples therefore is the recommended strategy for this type of longitudinal study as it yields more correct and detailed information than the immunoassay results.


Asunto(s)
Benzodiazepinas , Prisiones , Detección de Abuso de Sustancias/métodos , Trastornos Relacionados con Sustancias/epidemiología , Bélgica/epidemiología , Cromatografía de Gases y Espectrometría de Masas/métodos , Humanos , Estudios Longitudinales , Masculino , Prevalencia
4.
Clin Chim Acta ; 103(2): 209-17, 1980 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-7371199

RESUMEN

A rapid, sensitive and specific liquid chromatographic method is described for the determination of doxycycline in human tissues. The procedure involves mechanical homogenization of tissue samples in hydrochloric acid followed by extraction of the drug and an internal standard into ethyl acetate. Chromatographic separation is performed on a reversed phase column and allows quantitation of tissue levels as low as 0.68 nmol/g using a 200-400 mg sample. Application of the assay to tissue samples obtained from 36 patients confirmed the excellent penetration of doxycycline in organs. The method supersedes the classical microbiological assays in specificity and speed.


Asunto(s)
Doxiciclina/análisis , Apéndice/análisis , Cromatografía Liquida/métodos , Doxiciclina/sangre , Duodeno/análisis , Vesícula Biliar/análisis , Humanos , Ácido Clorhídrico , Epiplón/análisis , Distribución Tisular
5.
Clin Chim Acta ; 144(2-3): 95-103, 1984 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-6529864

RESUMEN

In Belgium, external quality assessment of health laboratories is organised according to the directives of the government. The programme in the discipline haematology, as conceived by our laboratory, has now been carried out for about two and a half years. The results obtained in the different surveys are reported. A few general conclusions on the state of the art of laboratory performance in routine haematological tests are drawn from these experimental data.


Asunto(s)
Hematología/normas , Laboratorios/normas , Bélgica , Recuento de Células Sanguíneas/instrumentación , Índices de Eritrocitos/normas , Hematología/instrumentación , Hemoglobinometría/instrumentación , Humanos , Control de Calidad
6.
Clin Chim Acta ; 152(1-2): 143-54, 1985 Oct 31.
Artículo en Inglés | MEDLINE | ID: mdl-3840418

RESUMEN

Human plasma and serum levels for 1 alpha,25-dihydroxyvitamin D were determined by a cytosol radioreceptor assay (RRA) and a radioimmunoassay (RIA). For both assays, 1.5 ml of human serum or plasma is used. Prior to RRA or RIA, extraction with benzene is performed followed by 'high-performance' liquid chromatography (HPLC) on a silica column (25 X 0.46 cm) with hexane/isopropanol (9/1 by vol), to isolate 1 alpha,25-dihydroxyvitamin D from the other vitamin D metabolites. The cytosol receptor was isolated from the intestine of healthy chickens. The antisera were raised in rabbits to 1 alpha,25-dihydroxyvitamin D3-3-hemisuccinate coupled to bovine serum albumin. The standard curves for RRA and RIA are prepared with 1 alpha,25-dihydroxyvitamin D3. 1 alpha,25-dihydroxy[3H]vitamin D3 of high spec act (158 kCi/mol) is used as tracer. The reactants are incubated for 16 h at 4 degrees C. Then, bound and free ligand are separated after the addition of dextran-coated charcoal. Both assays have a sensitivity of 2 pg/tube. The cytosol receptor and the antibodies have about the same absolute affinity for 1 alpha,25-dihydroxyvitamin D3 but the cytosol receptor has a higher relative affinity for 1 alpha,25-dihydroxyvitamin D3 (compared with other vitamin D metabolites). Reproducibility and precision are better for the RIA. The between- and within-assay CVs are 16.0% (mean = 58.7 ng/l, n = 16) and 11.2% (mean = 52.1 ng/l, n = 15), respectively, for RRA and 12.6% (mean = 61.8 ng/l, n = 27) and 7.4% (mean = 61.8 ng/l, n = 15), respectively using RIA. Reference values obtained by both assays on healthy males and healthy premenopausal females are the same for both sexes; 53.9 +/- 31.0 ng/l (n = 46) using RRA and 51.8 +/- 30.2 ng/l (n = 91) for RIA (mean +/- 2 SD).


Asunto(s)
Calcitriol/sangre , Adolescente , Adulto , Animales , Cromatografía Líquida de Alta Presión , Reacciones Cruzadas , Citosol/análisis , Femenino , Humanos , Fallo Renal Crónico/sangre , Masculino , Persona de Mediana Edad , Conejos , Radioinmunoensayo/métodos , Ensayo de Unión Radioligante/métodos , Factores Sexuales , Factores de Tiempo
7.
Clin Chim Acta ; 156(3): 247-57, 1986 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-3719983

RESUMEN

A liquid chromatographic procedure for the quantitative determination of the thiazine dye azure B, the principal constituent of Romanowsky stains, is presented. Unlike previous methods relying on peak area normalization, the present approach involves real quantitation through calibration with the reference standard azure B tetrafluoroborate. The method has been used for the quality control of commercial azure B preparations and to study their stability in stock and staining solutions, either or not in the presence of eosin Y. Results suggest that highly pure azure B perchlorate meets the requirements of a reference material, useful for standardization of Romanowsky-Giemsa staining in haematology.


Asunto(s)
Colorantes Azulados/normas , Encefalina Metionina/análogos & derivados , Fenotiazinas/normas , Colorantes Azulados/análisis , Calibración , Cromatografía Líquida de Alta Presión , Encefalina Metionina/administración & dosificación , Encefalina Metionina/farmacología , Control de Calidad , Estándares de Referencia , Soluciones
8.
Clin Chim Acta ; 71(2): 229-38, 1976 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-963892

RESUMEN

A method for the evaluation of results in external quality control surveys is developed on purely statistical grounds. This system allows to establish accuracy and precision of assay methods by comparing statistical data from subsequent surveys. However, for a particular survey the overall accuracy, precision and quality of each laboratory are defined in statistical terms and visually displayed. Results for each laboratory are summarized on a two-page computer printout. Per component assayed and combining all components determined in the particular survey, the laboratory is assigned one of the four possible qualifications i.e. "very good", "moderate" or "bad". A few general conclusions drawn from experimental data of previous surveys are reported.


Asunto(s)
Laboratorios , Control de Calidad , Estadística como Asunto , Glucemia/análisis , Química Clínica , Computadores , Humanos , Métodos , Urea/sangre , Ácido Úrico/sangre
9.
Clin Chim Acta ; 168(3): 337-46, 1987 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-3677432

RESUMEN

Laboratory results submitted to External Quality Assessment Schemes (EQAS) are evaluated against the arithmetic mean (m) and standard deviation (SD) of the result from other participants assuming a normal distribution of individual results. The sample statistics m and SD can only be reliable estimates of the theoretical mean (mu) and standard deviation (sigma), if they are not distorted by outlying values. Outliers are commonly detected by defining a confidence interval m +/- k SD, typically with k-values fixed at 3.0 or 3.2. The objective of our study was to prove the deficiency of the use of these fixed limits in large-scale EQAS, because it results in an unacceptable increase of outlier rate and hence in a serious distortion of the estimate of sigma. We have proposed a modified approach using a variable k-value which is dependent upon sample size and keeping the significance level constant at 5%. The influence of different decision limits on the number of outliers and on the sample statistics m and SD was compared using data from the Belgian National EQAS obtained in 6 consecutive surveys.


Asunto(s)
Análisis Químico de la Sangre , Laboratorios/normas , Glucemia/análisis , Humanos , Hidrocortisona/sangre , Hierro/sangre , Probabilidad , Control de Calidad
10.
Clin Chim Acta ; 133(1): 1-14, 1983 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-6688765

RESUMEN

A description is given of one of the existing National External Quality Assessment Schemes as organised in Belgium. The results of the six surveys held in 1981 in the disciplines Clinical Chemistry and Hormonology are reported. A few general conclusions are drawn from experimental data.


Asunto(s)
Análisis Químico de la Sangre/métodos , Química Clínica/métodos , Laboratorios/normas , Análisis de Varianza , Animales , Bélgica , Bovinos , Hormonas/análisis , Hormonas/normas , Humanos , Control de Calidad , Programas Informáticos
11.
Clin Chim Acta ; 172(2-3): 275-89, 1988 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-3370842

RESUMEN

Weanling rats were fed vitamin A deficient diets (-A) or diets supplemented with vitamin A (+A) (4.4 mg retinol equivalents/kg diet) for a period of 7 or 6 wk, respectively. In liver tissues of these two groups of animals both the subcellular localization as well as the fatty acid composition of the retinyl esters was studied. During vitamin A supplementation or deprivation, the kinetics of the different ester forms were investigated. Results indicate that the subcellular localization of all retinyl esters is similar and dependent on age. Two pools exist, ie one consisting of the nuclear/cell debris and mitochondrial-lysosomal fractions and the other containing the microsomal and cytosol fractions. HPLC analysis showed retinyl palmitate as the predominating (80%) form of the various retinyl esters. By supplementation clearly two kinetic behaviours can be demonstrated: one being a relatively stable storage of the palmitate and stearate, increasing with time and the second one being a more labile pattern for the ester forms with other saturated and unsaturated fatty acids. By vitamin A depletion all retinyl esters are affected indicating that the ester forms other than palmitate and stearate are also storage forms of vitamin A.


Asunto(s)
Ácidos Grasos/análisis , Hígado/análisis , Deficiencia de Vitamina A/metabolismo , Vitamina A/farmacocinética , Animales , Cromatografía , Ésteres/farmacocinética , Hígado/enzimología , Masculino , Ratas , Ratas Endogámicas
12.
Clin Chim Acta ; 170(1): 37-44, 1987 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-3124987

RESUMEN

For this sensitive RIA for 1 alpha,25-dihydroxyvitamin D, we used antibodies to 1 alpha,25-dihydroxycholecalciferol-3-hemisuccinate conjugated to bovine serum albumin, raised in eggs by immunization of chickens. We describe an efficient method for purification of IgG from egg yolk. We characterized these antibodies with immunoelectrophoresis and by radioimmunoassay. These antibodies show a high affinity for 1 alpha,25-dihydroxyvitamin D3 but cross react with other vitamin D metabolites as well. Extraction and liquid chromatography are necessary to isolate the 1 alpha,25-dihydroxyvitamin D from human serum or plasma before determination by RIA. The sensitivity of the assay is estimated at 5 pg/tube.


Asunto(s)
Calcitriol/inmunología , Yema de Huevo/inmunología , Sueros Inmunes/aislamiento & purificación , Animales , Especificidad de Anticuerpos , Pollos , Cadenas gamma de Inmunoglobulina/aislamiento & purificación , Radioinmunoensayo
13.
Clin Chim Acta ; 114(2-3): 249-56, 1981 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-7285348

RESUMEN

Different high performance liquid chromatographic systems were applied to the investigation of vitamin A metabolism in subjects undergoing haemodialysis. Plasma levels of retinol, retinyl esters and retinoic acid were measured. There was a significant elevation of plasma retinol and dialysis failed to normalise this level. No correlation with plasma concentrations of creatinine or urea was found. No differences in retinyl ester and retinoic acid levels were observed between healthy subjects and haemodialysis patients. These results suggest that retinol accumulation is not caused by a deficiency in its oxidative metabolism.


Asunto(s)
Fallo Renal Crónico/sangre , Diálisis Renal , Vitamina A/sangre , Adulto , Cromatografía Líquida de Alta Presión , Creatinina/sangre , Ésteres , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tretinoina/sangre , Urea/sangre , Vitamina A/metabolismo
14.
Clin Chim Acta ; 203(1): 57-65, 1991 Nov 09.
Artículo en Inglés | MEDLINE | ID: mdl-1769121

RESUMEN

Endogenous 13-cis- and all-trans-retinoic acids have been quantitated in human serum using a solvent extraction procedure followed by isocratic reversed phase high performance liquid chromatography and UV detection. In healthy adults, after an overnight fasting period, the concentrations of 13-cis- and all-trans-retinoic acids yielded 5.3 +/- 2.43 nmol/l and 11.8 +/- 3.3 nmol/l, respectively (mean +/- SD). The method has been successfully applied to the analysis of both isomers in serum from patients with idiopathic skeletal hyperostosis in whom, the 13-cis- as well as all-trans-retinoic acid levels were raised as compared to the control group.


Asunto(s)
Hiperostosis Esquelética Difusa Idiopática/sangre , Isotretinoína/sangre , Tretinoina/sangre , Adulto , Anciano , Anciano de 80 o más Años , Cromatografía Líquida de Alta Presión , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proteínas de Unión al Retinol/análisis , Espectrofotometría Ultravioleta , Vitamina A/sangre
15.
Nucl Med Biol ; 20(3): 359-62, 1993 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-8485496

RESUMEN

The purpose of this study was to investigate the possibility of using [11C]thymidine as a tumor marker for positron emission tomography studies. Biodistribution studies were set up to investigate the in vivo behavior of [11C]thymidine. Simultaneously, the DNA incorporation in fast dividing tissues and catabolism was studied. Our results confirm that [11C]thymidine can be used for detection of cell proliferation by positron emission tomography. As such, it can produce supplementary information in cancer research.


Asunto(s)
División Celular/fisiología , Timidina , Animales , Radioisótopos de Carbono , ADN/metabolismo , Humanos , Masculino , Neoplasias/metabolismo , Ratas , Ratas Wistar , Timidina/farmacocinética , Distribución Tisular
16.
J Chromatogr A ; 910(1): 105-18, 2001 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-11263563

RESUMEN

GC-MS screening conditions were developed for 15 low-dosed benzodiazepines, covering alprazolam, flunitrazepam, flurazepam, ketazolam, lorazepam and triazolam, and the corresponding metabolites alpha-hydroxyalprazolam, 4-hydroxyalprazolam; 7-aminoflunitrazepam, desmethylflunitrazepam, 7-aminodesmethylflunitrazepam; hydroxyethylflurazepam, N-desalkylflurazepam; oxazepam and alpha-hydroxytriazolam, respectively. Benzodiazepines are analyzed on a polydimethylsiloxane column in both the scan and the multiple ion monitoring modes using on-column injection to attain maximal sensitivity. The reactive compounds are acetylated with pyridine and acetic anhydride for 20 min. The derivatives are stable for at least 4 days. The relative standard deviation observed with standard compounds at the low nanogram-level ranged from 1.13 to 4.87% within-day and from 1.12 to 4.94% between-day. Unequivocal identification potential, high chromatographic resolution and sensitivity are combined with minimal thermal degradation. The presented screening conditions provide the basis for a unique routine screening method for low-dosed benzodiazepines with a broad polarity range.


Asunto(s)
Benzodiazepinas/química , Cromatografía de Gases y Espectrometría de Masas/métodos , Acetilación , Estándares de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
17.
J Chromatogr A ; 896(1-2): 275-8, 2000 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-11093662

RESUMEN

We describe the first results of a quantitative LC-tandem mass spectrometry method for urinary C-peptide with the use of [2H14]C-peptide as internal standard. LC was based on gradient elution of a Hypersil PEP C18 column. Mass spectrometry was performed in the negative electrospray ionization mode and by monitoring of the transitions at m/z 1514/1334 ([2H14]C-peptide) and 1507/1320 (C-peptide). For sample preparation, we applied ultrafiltration. The analytical performance of the method in terms of measurement precision gave an RSD of <2% (n=10). The overall imprecision was investigated from independent analysis of two urine samples in six-fold and resulted in an RSD<5%. The limit of detection, expressed as signal-to-noise ratio 3, was approximately 0.15 ng C-peptide injected. Analysis of 10 random urine samples from laboratory volunteers showed interference-free ion chromatograms at a signal-to-noise ratio of approximately 75 on average. The C-peptide concentrations calculated from quantification by the bracketing calibration technique ranged from 32 to 165 ng/ml.


Asunto(s)
Cromatografía Liquida/métodos , Espectrometría de Masas/métodos , Calibración , Deuterio , Humanos , Estándares de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
18.
J Chromatogr A ; 896(1-2): 311-9, 2000 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-11093666

RESUMEN

We report a precise and reliable method for the detection of 18 of the most commonly found opiates on the Belgian legal and illicit market, by ion-exchange, reversed-phase high-performance liquid chromatography, using a conventional phenyl-type analytical column (150x4.6 mm I.D., particle size 5 microm) and diode-array detection. We also describe a performance (efficiency and sensitivity) comparison of this column to a recently developed "high-speed" column (53x7.0 mm I.D., particle size 3 microm) packed with the same stationary phase, and used under slightly adjusted flow and gradient conditions. The final method, using the "high-speed" column, showed a significant reduction (55%) in analysis time without loss of resolution and sensitivity.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Medicina Legal , Narcóticos/análisis , Tampones (Química) , Cationes , Narcóticos/toxicidad , Estándares de Referencia , Sensibilidad y Especificidad , Espectrofotometría Ultravioleta
19.
Artículo en Inglés | MEDLINE | ID: mdl-12015270

RESUMEN

A fast liquid chromatographic method with tandem diode array-fluorescence detection for the simultaneous determination of in total 17 opium alkaloids and opioids is presented. Blank blood and urine samples (1 ml) were spiked with different concentrations of a standard mixture, as well as with the internal standard, butorphanol (2000 ng/ml). After solid-phase extraction, based on weak cation exchange (Bond Elut CBA SPE columns), the extracts were examined by HPLC-DAD-FL. By using a "high-speed" phenyl column (53 x 7.0 mm I.D., particle size 3 microm) eluted with a gradient system (A: water-methanol (90:10, v/v), B: methanol, both containing 25 mM triethylammoniumformate (pH(A) = 4.5)) all compounds could be baseline separated within 12 min. The method was validated and its applicability was demonstrated by the analysis of real-time forensic cases.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Narcóticos/análisis , Opio/análisis , Espectrometría de Fluorescencia/métodos , Espectrofotometría Ultravioleta/métodos , Cromatografía por Intercambio Iónico , Narcóticos/sangre , Narcóticos/orina , Opio/sangre , Opio/orina , Estándares de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
20.
J Pharm Sci ; 67(3): 417-9, 1978 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-147936

RESUMEN

A specific GLC method was developed for the determination of floxuridine in plasma using the thermionic nitrogen detector. The method involves the isolation of the compound and internal standard from plasma on a strong anion-exchange column at pH 10, followed by elution with 0.3 M acetic acid in methanol. The eluate is evaporated to dryness, and the residue is dissolved in dimethyl sulfoxide and permethylated with potassium tert-butoxide and methyl iodide. The permethylated compounds are reextracted from the reaction mixture with cyclohexane-methylene dichloride (9:1). The organic solution is evaporated to dryness, the residue is dissolved in ethyl acetate, and an aliquot is analyzed by GLC on a 3% OV-17 column. The extraction recovery from spiked plasma was 93.2 +/- 2.1% (SD), whereas linearity for the overall procedure was in the 0-1-microgram/ml range. The detection limit of the thermionic nitrogen detector was 50 ng/ml. The within-run and within days precision (CV) were 4.0 and 6.2%, respectively, at 300 ng/ml.


Asunto(s)
Floxuridina/sangre , Cromatografía de Gases/instrumentación , Cromatografía de Gases/métodos , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA