Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Magn Reson Med ; 85(5): 2904-2914, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33347642

RESUMEN

PURPOSE: This work aims to demonstrate the use of an "active" acousto-optic marker with enhanced visibility and reduced radiofrequency (RF) -induced heating for interventional MRI. METHODS: The acousto-optic marker was fabricated using bulk piezoelectric crystal and π-phase shifted fiber Bragg grating (FBGs) and coupled to a distal receiver coil on an 8F catheter. The received MR signal is transmitted over an optical fiber to mitigate RF-induced heating. A photodetector converts the optical signal into electrical signal, which is used as the input signal to the MRI receiver plug. Acousto-optic markers were characterized in phantom studies. RF-induced heating risk was evaluated according to ASTM 2182 standard. In vivo real-time tracking capability was tested in an animal model under a 0.55T scanner. RESULTS: Signal-to-noise ratio (SNR) levels suitable for real-time tracking were obtained by using high sensitivity FBG and piezoelectric transducer with resonance matched to Larmor frequency. Single and multiple marker coils integrated to 8F catheters were readout for position and orientation tracking by a single acousto-optic sensor. RF-induced heating was significantly reduced compared to a coax cable connected reference marker. Real-time distal tip tracking of an active device was demonstrated in an animal model with a standard real-time cardiac MR sequence. CONCLUSION: Acousto-optic markers provide sufficient SNR with a simple structure for real-time device tracking. RF-induced heating is significantly reduced compared to conventional active markers. Also, multiple RF receiver coils connected on an acousto-optic modulator can be used on a single catheter for determining catheter orientation and shape.


Asunto(s)
Imagen por Resonancia Magnética Intervencional , Imagen por Resonancia Magnética , Animales , Catéteres , Diseño de Equipo , Fantasmas de Imagen
2.
IEEE J Solid-State Circuits ; 55(5): 1310-1323, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32341598

RESUMEN

In this article, we present a highly integrated guidewire ultrasound (US) imaging system-on-a-chip (GUISoC) for vascular imaging. The SoC consists of a 16-channel US transmitter (Tx) and receiver (Rx) electronics, on-chip power management IC (PMIC), and quadrature sampler. Using a synthetic aperture imaging algorithm, a Tx/Rx pair, connected to capacitive micromachined ultrasound transducers (CMUTs), can be activated at any time. The Tx generates acoustic waves by driving the CMUT, while the Rx picks up the echo signal and amplify it to be delivered through an interconnect that is driven by a buffer. On-chip logic controls the pulsers that generate the high-voltage (HV)-pulse for Tx. An on-chip PMIC provides 1.8-, 5-, 39-, and 44-V supplies and a clock signal from the two interconnects besides GND. A quadrature sampler down-converts the Rx echo signal to baseband, reducing its bandwidth requirement for the output interconnect. The system design, including transimpedance amplifier (TIA) optimization, based on the equivalent circuit of a specific CMUT is presented. The SoC was fabricated by a 0.18-µm HV CMOS process, occupying 1.5-mm2 active area and consuming 25.2 and 44 mW from 1.8 to 44 V supplies, respectively. The US Tx and Rx show bandwidths of 32-42 and 32.7-37.5 MHz, respectively. The input-referred noise of the system was measured as 9.66 nA in band with 2-m-long 52 American Wire Gauge (AWG) wire interconnects. The functionality of the GUISoC was verified in vitro by imaging wire targets.

3.
IEEE Sens J ; 20(17): 9955-9962, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32831800

RESUMEN

A power-efficient bridge-to-digital sensing interface is proposed, which also offers immunity against power supply noise. The interface utilizes duty-cycling to reduce the static power consumption of resistive bridge sensors, which are commonly used in implantable, wearable, and internet of things (IoT) applications, such as intracranial pressure (ICP) sensing and blood pressure (BP) monitoring. The proposed interface uses a revised version of the pseudo-pseudo differential (PPD) topology with the ping-pong technique to reduce the complexity of traditional fully-differential counterparts. A proof-of-concept prototype has been fabricated in 0.35-µm CMOS and occupies an active area of 0.48 mm2. It achieves 9.13 effective number of bits (ENOB) at 3.72 kHz sampling rate and improvement of more than 50 dB in the power supply rejection ratio (PSRR) by employing the ping-pong technique. It reduces the power consumption of a 5-kΩ Wheatstone bridge by 99.6% compared to a traditional interface, down to 2.53 µw at 1.8 V supply. The functionality of the system has also been demonstrated in an experimental setup in conjunction with an embedded resistive bridge pressure sensor.

4.
IEEE Sens J ; 19(2): 603-614, 2019 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-31572068

RESUMEN

A sensor interface circuit based on impulse radio pulse width modulation (IR-PWM) is presented for low power and high throughput wireless data acquisition systems (wDAQ) with extreme size and power constraints. Two triple-slope analog-to-time converters (ATC) convert two analog signals, each up to 5 MHz in bandwidth, into PWM signals, and an impulse radio (IR) transmitted (Tx) with an all-digital power amplifier (PA) combines them while preserving the timing information by transmitting impulses at the PWM rising and falling edges. On the receiver (Rx) side, an RF-LNA followed by an envelope detector recovers the incoming impulses, and a T-flipflop reverts the impulse sequence back to PWM to be digitized by a time-to-digital converter (TDC). Detailed analysis and design guideline on ATC was introduced, and a proof-of-concept prototype was fabricated for a capacitive micromachined ultrasound transducer (CMUT) imaging system in a 0.18-µm HV CMOS process, occupying 0.18 mm2 active area and consuming 3.94 mW from a 1.8 V supply. The proposed TDC in this prototype yielded 7-bit resolution, while the entire wDAQ achieved 5.8 effective number of bits (ENOB) at 2 × 10 MS/s.

5.
IEEE Sens J ; 19(24): 12050-12058, 2019 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-34079429

RESUMEN

A combined supply-inverted bipolar pulser and a Tx/Rx switch is proposed to drive capacitive micromachined ultrasonic transducers (CMUTs). The supply-inverted bipolar pulser adopts a bootstrap circuit combined with stacked transistors, which guarantees high voltage (HV) operation above the process limit without lowering device reliability. This circuit generates an output signal with a peak-to-peak voltage that is almost twice the supply level. It generates a bipolar pulse with only positive supply voltages. The Tx/Rx switch adopts a diode-bridge structure with the protection scheme dedicated to this proposed pulser. A proof- of-concept ASIC prototype has been implemented in 0.18-µm HV CMOS/DMOS technology with 60 V devices. Measurement results show that the proposed pulser can safely generate a bipolar pulse of -34.6 to 45 V, from a single 45 V supply voltage. The Tx/Rx switch blocks the HV bipolar pulse, resulting in less than 1.6 V at the input of the receiver. Acoustic measurements are performed connecting the pulser to CMUTs with 2 pF capacitance and 8 MHz center frequency. The variation of acoustic output pressures for different pulse shapes were simulated with the large signal CMUT model and compared with the experimental results for transmit pressure optimization. A potential implementation of the methods using MEMS fabrication methods is also described.

6.
Sensors (Basel) ; 19(4)2019 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-30791556

RESUMEN

With Capacitive Micromachined Ultrasound Transducers (CMUTs) increasingly being used for high intensity, large signal ultrasound applications and several drive methods being proposed, the efficiency of these devices in this operation regime have not been quantitatively evaluated. Since well-known frequency and capacitance-based coupling coefficients definitions are not valid for large signal, nonlinear operation, an energy-based definition should be used. In this paper, an expression for mechanical energy in a CMUT is obtained based on the assumption that CMUT is a linear time varying capacitor in all regimes of operation. This expression is evaluated by the help of an experimentally verified nonlinear CMUT model to define an energy conversion ratio (ECR) which can be considered as a coupling coefficient valid for all regimes of operation. This parameter is validated in the small signal regime and then used to evaluate CMUT performance with various large drive signals. The quantitative modeling results show that CMUTs do not need DC bias to achieve high efficiency large signal transduction: AC only signals at half the operation frequency with amplitudes beyond the collapse voltage can provide efficiencies (ECR) above 0.9 with harmonic content below -25 dB. Based on these results, ECR variation with membrane geometry and parasitic capacitance are given as examples for device optimization. The overall modeling approach is also qualitatively validated by experiments.

7.
J Micromech Microeng ; 28(8)2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29785066

RESUMEN

This paper reports an improved CMOS compatible low temperature sacrificial layer fabrication process for Capacitive Micromachined Ultrasonic Transducers (CMUTs). The process adds the fabrication step of silicon oxide evaporation which is followed by a lift-off step to define the membrane support area without a need for an extra mask. This simple addition improves reliability by reducing the electric field between the top and bottom electrodes everywhere except the moving membrane without affecting the vacuum gap thickness. Furthermore, the parasitic capacitance which degrades the CMUT receive performance is reduced. A 1-D CMUT array suitable for Intracardiac Echocardiography (ICE) imaging with 9MHz center frequency is fabricated using this method. Detailed electrical and acoustic testing indicates adequate performance of the devices for ICE in agreement with simulations. Long term output pressure testing with more than 2×1011 pulsing cycles and environmental testing demonstrate the efficacy of the approach for improved reliability as compared to devices without the additional membrane support layer.

8.
J Acoust Soc Am ; 135(6): EL364-70, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24907847

RESUMEN

Monolithic integration of capacitive micromachined ultrasonic transducer arrays with low noise complementary metal oxide semiconductor electronics minimizes interconnect parasitics thus allowing the measurement of thermal-mechanical (TM) noise. This enables passive ultrasonics based on cross-correlations of diffuse TM noise to extract coherent ultrasonic waves propagating between receivers. However, synchronous recording of high-frequency TM noise puts stringent requirements on the analog to digital converter's sampling rate. To alleviate this restriction, high-frequency TM noise cross-correlations (12-25 MHz) were estimated instead using compressed measurements of TM noise which could be digitized at a sampling frequency lower than the Nyquist frequency.

9.
Artículo en Inglés | MEDLINE | ID: mdl-38833386

RESUMEN

Intravascular ultrasound (IVUS) imaging catheters are significant tools for cardiovascular interventions, and their use can be expanded by realizing IVUS imaging guidewires and microcatheters. The miniaturization of these devices creates challenges in SNR due to the need for higher frequencies to provide adequate resolution. An integrated IVUS system with transmit beamforming can mitigate these limitations. This work presents the first practical highly integrated system-on-a-chip (SoC) with plane wave transmit beamforming at 40 MHz for IVUS on guidewire or microcatheters. The front-end circuitry has a 20-channel ultrasound transmitter (Tx) and receiver (Rx) array interfaced with a capacitive micromachined ultrasound transducer (CMUT) array. During each firing, all 20 Tx are excited with the same analog delay with respect to each other, which can be continuously adjusted between ~0 and 10 ns in two directions, generating a steerable plane wave in a range of ±/-50° for a phased array at 40 MHz. The unit delays are generated via a voltage-controlled delay line (VCDL), which only needs two external controls, one tuning the unit delay and the other determining the steering direction. The SoC is fabricated using a 180-nm high-voltage (HV) CMOS process and features a slender active area of 0.3 mm × 3.7 mm. The proposed SoC consumes 31.3 mW during the receiving mode. The beamformer's functionality and the SoC's overall performance were validated through acoustic characterization and imaging experiments.

10.
IEEE Trans Biomed Circuits Syst ; 16(4): 492-501, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35687616

RESUMEN

This paper presents an active impedance matching scheme that tries to optimize electrical power transfer and acoustic reflectivity in ultrasound transducers. Leveraging negative capacitance-based impedance matching would potentially improve the bandwidth and electrical power transfer while minimizing acoustic reflection of transducer elements and improve uniformity while reducing acoustic crosstalk of transducer arrays. A 16-element transceiver front-end is designed which employs an element-level active capacitive impedance cancellation scheme using an element-level negative impedance converter. The ASIC fabricated in 180-nm HVBCD technology provides high-voltage pulses up to 60 V consuming 3.6 mW and occupying 2.5 mm2. The front-end ASIC is used with a 1-D capacitive micromachined ultrasonic transducer (CMUT) array and its acoustical reflectivity reduction and imaging capabilities have successfully been demonstrated through pulse-echo measurements and acoustic imaging experiments.


Asunto(s)
Acústica , Transductores , Impedancia Eléctrica , Diseño de Equipo , Ultrasonografía/métodos
11.
Sci Adv ; 8(46): eadd2288, 2022 11 16.
Artículo en Inglés | MEDLINE | ID: mdl-36399574

RESUMEN

Despite the challenges in treating glioblastomas (GBMs) with immune adjuvants, increasing evidence suggests that targeting the immune cells within the tumor microenvironment (TME) can lead to improved responses. Here, we present a closed-loop controlled, microbubble-enhanced focused ultrasound (MB-FUS) system and test its abilities to safely and effectively treat GBMs using immune checkpoint blockade. The proposed system can fine-tune the exposure settings to promote MB acoustic emission-dependent expression of the proinflammatory marker ICAM-1 and delivery of anti-PD1 in a mouse model of GBM. In addition to enhanced interaction of proinflammatory macrophages within the PD1-expressing TME and significant improvement in survival (P < 0.05), the combined treatment induced long-lived memory T cell formation within the brain that supported tumor rejection in rechallenge experiments. Collectively, our findings demonstrate the ability of MB-FUS to augment the therapeutic impact of immune checkpoint blockade in GBMs and reinforce the notion of spatially tumor-targeted (loco-regional) brain cancer immunotherapy.


Asunto(s)
Neoplasias Encefálicas , Glioblastoma , Animales , Ratones , Inhibidores de Puntos de Control Inmunológico/farmacología , Inhibidores de Puntos de Control Inmunológico/uso terapéutico , Inmunoterapia , Neoplasias Encefálicas/terapia , Encéfalo , Factores Inmunológicos , Glioblastoma/terapia , Microambiente Tumoral
12.
Adv Drug Deliv Rev ; 180: 114043, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34801617

RESUMEN

Brain tumors are particularly challenging malignancies, due to their location in a structurally and functionally distinct part of the human body - the central nervous system (CNS). The CNS is separated and protected by a unique system of brain and blood vessel cells which together prevent most bloodborne therapeutics from entering the brain tumor microenvironment (TME). Recently, great strides have been made through microbubble (MB) ultrasound contrast agents in conjunction with ultrasound energy to locally increase the permeability of brain vessels and modulate the brain TME. As we elaborate in this review, this physical method can effectively deliver a wide range of anticancer agents, including chemotherapeutics, antibodies, and nanoparticle drug conjugates across a range of preclinical brain tumors, including high grade glioma (glioblastoma), diffuse intrinsic pontine gliomas, and brain metastasis. Moreover, recent evidence suggests that this technology can promote the effective delivery of novel immunotherapeutic agents, including immune check-point inhibitors and chimeric antigen receptor T cells, among others. With early clinical studies demonstrating safety, and several Phase I/II trials testing the preclinical findings underway, this technology is making firm steps towards shaping the future treatments of primary and metastatic brain cancer. By elaborating on its key components, including ultrasound systems and MB technology, along with methods for closed-loop spatial and temporal control of MB activity, we highlight how this technology can be tuned to enable new, personalized treatment strategies for primary brain malignancies and brain metastases.


Asunto(s)
Antineoplásicos/administración & dosificación , Neoplasias Encefálicas/tratamiento farmacológico , Sistemas de Liberación de Medicamentos , Animales , Antineoplásicos/farmacocinética , Neoplasias Encefálicas/patología , Glioma/tratamiento farmacológico , Glioma/patología , Humanos , Microburbujas , Sonicación , Microambiente Tumoral
13.
IEEE Trans Biomed Circuits Syst ; 16(5): 972-980, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36074865

RESUMEN

This paper demonstrates hybrid sub-aperture beamforming (SAB) with time-division multiplexing (TDM) for massive interconnect reduction in ultrasound imaging systems. A single-chip front-end system prototype has been fabricated in 180-nm HV BCD technology that combines 5×1 SAB with 8×1 TDM to efficiently reduce the number of receive signal interconnects by a factor of 40. The system includes on-chip high-voltage (HV) pulsers capable of generating unipolar pulses up to 70 V in transmit (TX) mode. The receiver (RX) chain consists of a T/R switch, a variable-gain low-noise amplifier (VG-LNA) with 4-step gain control (15-32 dB) for time-gain compensation followed by a programmable switched-capacitor analog delay-and-sum beamformer. The proof-of-concept prototype operates at a 200-MHz clock frequency and the SAB provides 32-step fine delays with a maximum delay of 310 ns corresponding to better than λ/20 delay quantization at 5 MHz. With these specifications, the SAB is capable of beam steering from 0 ° to 45 ° for a 5-element subarray with 150-micron pitch ( λ/2), providing a near-ideal phased array imaging performance. The sub-aperture beamformer is followed by the TDM system where each of the 8 channels is sampled at a rate of 25 MS/s after an anti-aliasing bandpass filter. The full functionality of the prototype chip is validated through electrical and acoustic measurements on a 1-D capacitive micromachined ultrasonic transducer (CMUT) array designed for intracardiac echocardiography (ICE).


Asunto(s)
Amplificadores Electrónicos , Transductores , Fantasmas de Imagen , Diseño de Equipo , Ultrasonografía/métodos
14.
Artículo en Inglés | MEDLINE | ID: mdl-33983883

RESUMEN

Tight integration of capacitive micromachined ultrasonic transducer (CMUT) arrays with integrated circuits can make active impedance matching feasible for practical imaging devices. In this article, negative capacitance-based impedance matching for CMUTs is investigated. Simple equivalent circuit model-based calculations show the potential of negative capacitance matching for improving the bandwidth along with electrical power transfer and acoustic reflectivity, but the model has limitations especially for acoustic reflectivity evaluation. For more realistic results, an experimentally validated CMUT array model is applied to a small 1-D CMUT array operating in the 5-15 MHz range. The results highlight the difference between electrical power transfer and acoustic reflectivity as well as the tradeoffs in signal-to-noise ratio (SNR). According to the results, ideal negative capacitance termination matched to the CMUT capacitance provides the broadest bandwidth and highest SNR if acoustic or electrical reflections are of no concern. On the other hand, negative capacitance and resistance matching to minimize acoustic reflectivity provides both lower reflection and closer to ideal SNR as compared with electrical power matching. It is observed that acoustic matching also reduces acoustic crosstalk and improves array uniformity. While several challenges for integrated circuit implementation are present, negative capacitance-based impedance matching can be a viable broadband active impedance matching method for CMUTs operating in conventional and collapsed mode as well as other ultrasound transducers with mainly capacitive impedance.


Asunto(s)
Transductores , Impedancia Eléctrica , Diseño de Equipo , Miniaturización , Ultrasonografía
15.
Anal Chem ; 82(1): 19-22, 2010 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-19904914

RESUMEN

The scanning mass spectrometry (SMS) probe is a new electrospray ion source. Motivated by the need for untargeted chemical imaging of dynamic events in solution, we have exploited an approach to electrospray ionization (ESI) that allows continuous sampling from a highly localized volume (approximately picoliters) in a liquid environment, softly ionizes molecules in the sample to render them amenable for mass spectrometric analysis, and sends the ions to the mass spectrometer. The key underlying concepts for our approach are (1) treating the electrospray capillary inlet as a chemical scanning probe and (2) locating the electrospray point as close as possible to the sampling point, thus providing the shortest response time possible. This approach enables chemical monitoring or imaging of submerged interfaces, providing access to details of spatial heterogeneity and temporal changes within liquid samples. It also permits direct access to liquid/ liquid interfaces for ESI-MS analysis. In this letter we report the first demonstrations of these capabilities of the SMS probe and describe some of the probe's basic characteristics.


Asunto(s)
Espectrometría de Masa por Ionización de Electrospray/métodos , Soluciones/química , Espectrometría de Masa por Ionización de Electrospray/instrumentación , Factores de Tiempo
16.
OSA Contin ; 3(3): 447-458, 2020 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-32457936

RESUMEN

Fiber Bragg grating (FBG) based sensors have recently been introduced to the field of magnetic resonance imaging (MRI). Real-time MRI applications demand highly amplitude and phase sensitive MRI compatible sensors. Thus, a model and detailed analysis of FBG based ultrasound detection are required for designing better performing sensors. A hybrid FBG model incorporating numerical and FEA methods was developed and used for sensitivity and linearity analysis. The transfer matrix method was used for the modeling of optical modulation whereas FEA was used for pressure field calculations within the grating. The model was verified through reflection spectrum and acoustic pressure sensitivity testing of two π-phase shifted FBGs in a side slope read-out configuration. The sensitivity curves with respect to the operation point on the side slope was characterized in terms of amplitude and phase, and nonlinearity of the phase response has been quantified. Lastly, the impact of phase linearity of the FBG based acousto-optic sensor was tested under MRI when the sensor was used as a position marker and an analog phase shifter based solution was demonstrated.

17.
Artículo en Inglés | MEDLINE | ID: mdl-30571620

RESUMEN

High-frequency ultrasound imaging arrays are important for a broad range of applications, from small animal imaging to photoacoustics. Capacitive micromachined ultrasonic transducer (CMUT) arrays are particularly attractive for these applications as low noise receiver electronics can be integrated for an overall improved performance. In this paper, we present a comprehensive analysis of high-frequency CMUT arrays based on an experimentally verified CMUT array simulation tool. The results obtained on an example, a 40-MHz 1-D CMUT array for intravascular imaging, are used to obtain key design insights and tradeoffs for receive only and pulse-echo imaging. For the receiver side, thermal mechanical current noise, plane wave pressure sensitivity, and pressure noise spectrum are extracted from simulations. Using these parameters, we find that the receiver performance of CMUT arrays can be close to an ideal piston, independent of gap thickness, and applied dc bias, when coupled to low noise electronics with arrays utilizing smaller membranes performing better. For pulse-echo imaging, thermal mechanical current noise limited signal-to-noise ratio is observed to be dependent on the maximum available voltage and gap thickness. In terms of bandwidth, we find that the Bragg resonance of the array, related to the fill factor, is a significant determinant of the high frequency limit and the fluid loaded single membrane resonance determines the lower limit. Based on these results, we present design guidelines requiring only fluid loaded single membrane simulations and membrane pitch to achieve a desired pulse-echo response. We also provide a design example and discuss limitations of the approach.


Asunto(s)
Transductores , Ultrasonografía/instrumentación , Algoritmos , Diseño de Equipo , Técnicas Fotoacústicas/instrumentación
18.
IEEE Trans Biomed Eng ; 66(4): 1148-1154, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30188810

RESUMEN

OBJECTIVE: The objective of this paper is to introduce an acousto-optic optical fiber sensor for tracking catheter position during interventional magnetic resonance imaging (MRI) to overcome RF induced heating of active markers. METHODS: The sensor uses a miniature coil coupled to a piezoelectric transducer, which is in turn mechanically connected to an optical fiber. The piezoelectric transducer converts the RF signal to acoustic waves in the optical fiber over a region including a fiber Bragg grating (FBG). The elastic waves in the fiber modulates the FBG geometry and hence the reflected light in the optical fiber. Since the coil is much smaller than the RF wavelength and the signal is transmitted on the dielectric optical fiber, the sensor effectively reduces RF induced heating risk. Proof of concept prototypes of the sensor are implemented using commercially available piezoelectric transducers and optical fibers with FBGs. The prototypes are characterized in a 1.5 T MRI system in comparison with an active tracking marker. RESULTS: Acousto-optical sensor shows linear response with flip angle and it can be used to detect signals from multiple coils for potential orientation detection. It has been successfully used to detect the position of a tacking coil in phantom in an imaging experiment. CONCLUSION: Acousto-optical sensing is demonstrated for tracking catheters during interventional MRI. Real-time operation of the sensor requires sensitivity improvements like using a narrow band FBG. SIGNIFICANCE: Acousto-optics provides a compact solution to sense RF signals in MRI with dielectric transmission lines.


Asunto(s)
Catéteres , Imagen por Resonancia Magnética Intervencional/métodos , Fibras Ópticas , Diseño de Equipo , Imagen por Resonancia Magnética Intervencional/instrumentación , Fantasmas de Imagen , Transductores
19.
J Am Soc Mass Spectrom ; 19(9): 1320-9, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18650100

RESUMEN

The internal energy deposition of a Venturi-assisted array of micromachined ultrasonic electrosprays (AMUSE), with and without the application of a DC charging potential, is compared with equivalent experiments for Venturi-assisted electrospray ionization (ESI) using the "survival yield" method on a series of para-substituted benzylpyridinium salts. Under conditions previously shown to provide maximum ion yields for standard compounds, the observed mean internal energies were nearly identical (1.93-2.01 eV). Operation of AMUSE without nitrogen flow to sustain the air amplifier focusing effect generated energetically colder ions with mean internal energies that were up to 39% lower than those for ESI. A balance between improved ion transfer, adequate desolvation, and favorable ion energetics was achieved by selection of optimum operational ranges for the parameters that most strongly influence the ion population: the air amplifier gas flow rate and API capillary temperature. Examination of the energy landscapes obtained for combinations of these parameters showed that a low internal energy region (

Asunto(s)
Espectrometría de Masa por Ionización de Electrospray/instrumentación , Espectrometría de Masa por Ionización de Electrospray/métodos , Diseño de Equipo , Compuestos de Piridinio/química , Termodinámica , Ultrasonido
20.
J Microelectromech Syst ; 17(3): 688-697, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19081811

RESUMEN

In many micromachined sensors the thin (2-10 µm thick) air film between a compliant diaphragm and backplate electrode plays a dominant role in shaping both the dynamic and thermal noise characteristics of the device. Silicon microphone structures used in grating-based optical-interference microphones have recently been introduced that employ backplates with minimal area to achieve low damping and low thermal noise levels. Finite-element based modeling procedures based on 2-D discretization of the governing Reynolds equation are ideally suited for studying thin-film dynamics in such structures which utilize relatively complex backplate geometries. In this paper, the dynamic properties of both the diaphragm and thin air film are studied using a modal projection procedure in a commonly used finite element software and the results are used to simulate the dynamic frequency response of the coupled structure to internally generated electrostatic actuation pressure. The model is also extended to simulate thermal mechanical noise spectra of these advanced sensing structures. In all cases simulations are compared with measured data and show excellent agreement-demonstrating 0.8 pN/√Hz and 1.8 µPa/√Hz thermal force and thermal pressure noise levels, respectively, for the 1.5 mm diameter structures under study which have a fundamental diaphragm resonance-limited bandwidth near 20 kHz.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA