Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Int J Mol Sci ; 23(10)2022 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-35628195

RESUMEN

The scaffold is a key element in the field of tissue engineering, especially when large defects or substitutions of pathological tissues or organs need to be clinically addressed. The expected outcome is strongly dependent on the cell-scaffold interaction and the integration with the surrounding biological tissue. Indeed, mimicking the natural extracellular matrix (ECM) of the tissue to be healed represents a further optimization that can limit a possible morphological mismatch between the scaffold and the tissue itself. For this aim, and referring to bone tissue engineering, polylactic acid (PLA) scaffolds were 3D printed with a microstructure inspired by the trabecular architecture and biologically evaluated by means of human osteosarcoma SAOS-2 cells. The cells were seeded on two types of scaffolds differing for the designed pore size (i.e., 400 and 600 µm), showing the same growth exponential trend found in the control and no significant alterations in the actin distribution. The microporous structure of the two tested samples enhanced the protein adsorption capability and mRNA expression of markers related to protein synthesis, proliferation, and osteoblast differentiation. Our findings demonstrate that 3D-printed scaffolds support the adhesion, growth, and differentiation of osteoblast-like cells and the microporous architecture, mimicking the natural bone hierarchical structure, and favoring greater bioactivity. These bioinspired scaffolds represent an interesting new tool for bone tissue engineering and regenerative medicine applications.


Asunto(s)
Ingeniería de Tejidos , Andamios del Tejido , Huesos , Humanos , Osteogénesis , Impresión Tridimensional , Andamios del Tejido/química
2.
Sci Rep ; 14(1): 1722, 2024 01 19.
Artículo en Inglés | MEDLINE | ID: mdl-38242930

RESUMEN

Intrinsic permeability describes the ability of a porous medium to be penetrated by a fluid. Considering porous scaffolds for tissue engineering (TE) applications, this macroscopic variable can strongly influence the transport of oxygen and nutrients, the cell seeding process, and the transmission of fluid forces to the cells, playing a crucial role in determining scaffold efficacy. Thus, accurately measuring the permeability of porous scaffolds could represent an essential step in their optimization process. In literature, several methods have been proposed to characterize scaffold permeability. Most of the currently adopted approaches to assess permeability limit their applicability to specific scaffold structures, hampering protocols standardization, and ultimately leading to incomparable results among different laboratories. The content of novelty of this study is in the proposal of an adaptable test bench and in defining a specific testing protocol, compliant with the ASTM International F2952-22 guidelines, for reliable and repeatable measurements of the intrinsic permeability of TE porous scaffolds. The developed permeability test bench (PTB) exploits the pump-based method, and it is composed of a modular permeability chamber integrated within a closed-loop hydraulic circuit, which includes a peristaltic pump and pressure sensors, recirculating demineralized water. A specific testing protocol was defined for characterizing the pressure drop associated with the scaffold under test, while minimizing the effects of uncertainty sources. To assess the operational capabilities and performance of the proposed test bench, permeability measurements were conducted on PLA scaffolds with regular (PS) and random (RS) micro-architecture and on commercial bovine bone matrix-derived scaffolds (CS) for bone TE. To validate the proposed approach, the scaffolds were as well characterized using an alternative test bench (ATB) based on acoustic measurements, implementing a blind randomized testing procedure. The consistency of the permeability values measured using both the test benches demonstrated the reliability of the proposed approach. A further validation of the PTB's measurement reliability was provided by the agreement between the measured permeability values of the PS scaffolds and the theory-based predicted permeability value. Once validated the proposed PTB, the performed measurements allowed the investigation of the scaffolds' transport properties. Samples with the same structure (guaranteed by the fused-deposition modeling technique) were characterized by similar permeability values, and CS and RS scaffolds showed permeability values in agreement with the values reported in the literature for bovine trabecular bone. In conclusion, the developed PTB and the proposed testing protocol allow the characterization of the intrinsic permeability of porous scaffolds of different types and dimensions under controlled flow regimes, representing a powerful tool in view of providing a reliable and repeatable framework for characterizing and optimizing scaffolds for TE applications.


Asunto(s)
Ingeniería de Tejidos , Andamios del Tejido , Animales , Bovinos , Ingeniería de Tejidos/métodos , Porosidad , Reproducibilidad de los Resultados , Andamios del Tejido/química , Permeabilidad
3.
Bone ; 182: 117065, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38428556

RESUMEN

INTRODUCTION: Human mesenchymal stem cells (hMSCs) sense and respond to biomechanical and biophysical stimuli, yet the involved signaling pathways are not fully identified. The clinical application of biophysical stimulation including pulsed electromagnetic field (PEMF) has gained momentum in musculoskeletal disorders and bone tissue engineering. METHODOLOGY: We herein aim to explore the role of PEMF stimulation in bone regeneration by developing trabecular bone-like tissues, and then, culturing them under bone-like mechanical stimulation in an automated perfusion bioreactor combined with a custom-made PEMF stimulator. After selecting the optimal cell seeding and culture conditions for inspecting the effects of PEMF on hMSCs, transcriptomic studies were performed on cells cultured under direct perfusion with and without PEMF stimulation. RESULTS: We were able to identify a set of signaling pathways and upstream regulators associated with PEMF stimulation and to distinguish those linked to bone regeneration. Our findings suggest that PEMF induces the immune potential of hMSCs by activating and inhibiting various immune-related pathways, such as macrophage classical activation and MSP-RON signaling in macrophages, respectively, while promoting angiogenesis and osteogenesis, which mimics the dynamic interplay of biological processes during bone healing. CONCLUSIONS: Overall, the adopted bioreactor-based investigation platform can be used to investigate the impact of PEMF stimulation on bone regeneration.


Asunto(s)
Campos Electromagnéticos , Transcriptoma , Humanos , Huesos , Regeneración Ósea , Reactores Biológicos
4.
Polymers (Basel) ; 16(18)2024 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-39339053

RESUMEN

Exposure to high levels of radiation can cause acute, long-term health effects, such as acute radiation syndrome, cancer, and cardiovascular disease. This is an important occupational hazard in different fields, such as the aerospace and healthcare industry, as well as a crucial burden to overcome to boost space applications and exploration. Protective bulky equipment made of heavy metals is not suitable for many advanced purporses, such as mobile devices, wearable shields, and manned spacecrafts. In the latter case, the in-space manufacturing of protective shields is highly desirable and remains an unmet need. Composites made of polymers and high atomic number fillers are potential means for radiation protection due to their low weight, good flexibility, and good processability. In the present work, we developed electrospun composites based on polycaprolactone (polymer matrix) and tungsten powder for application as shielding materials. Electrospinning is a versatile technology that is easily scalable at an industrial level and allows obtaining very lightweight, flexible sheet materials for wearables. By controlling tungsten powder size, we engineered homogeneous, stable and processable suspensions to fabricate radiation composite shielding sheets. The shielding capability was assessed by an in vivo model on prototype composite sheets containing 80 w% of W filler in a polycaprolactone (PCL) fibrous matrix by means of irradiation tests (X-rays) on mice. The obtained results are promising; as expected, the shielding effectivity of the developed composite material increases with the thickness/number of stacked layers. It is worth noting that a thin barrier consisting of 24 layers of the innovative shielding material reduces the extent of apoptosis by 1.5 times compared to the non-shielded mice.

5.
J Mater Sci Mater Med ; 24(2): 523-32, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23135411

RESUMEN

Thrombosis is the main cause of failure of small-diameter synthetic vascular grafts when used for by-pass procedures. The development of bioresorbable vascular scaffolds with localized and sustained intra-luminal antithrombotic drug release could be considered a desirable improvement towards a valuable solution for this relevant clinical need. For this aim, we present the fabrication and characterization of aspirin-loaded electrospun poly(ε-caprolactone) tubular scaffolds as a vascular drug-delivery graft. Three different drug concentrations were considered (i.e., 1, 5 or 10 % w/w). Although a fibrous structure was clearly observed for all the collected scaffolds, aspirin content was directly implied in the final microstructure leading to a bimodal fiber diameter distribution and fused fibers at crossing-points (5 or 10 % w/w). Mechanical response highlighted a direct relationship for modulus and stress at break with the aspirin content, while the elongation at break was not remarkably different for the investigated cases. The temporal drug release was strongly dependent from the amount of loaded aspirin, reaching a steady state release after about 50 h. Finally, the adhesion assay confirmed the capability of the electrospun scaffolds to reduce platelet adhesion/aggregation onto aspirin loaded polymeric fibers. Aspirin-loaded electrospun tubular scaffold could represent a feasible candidate to develop a novel bioresorbable drug-releasing graft for small-diameter vessel replacements.


Asunto(s)
Aspirina/administración & dosificación , Prótesis Vascular , Poliésteres/química , Trombosis/prevención & control , Andamios del Tejido , Materiales Biocompatibles/síntesis química , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacocinética , Vasos Sanguíneos/citología , Células Cultivadas , Sistemas de Liberación de Medicamentos , Stents Liberadores de Fármacos , Técnicas Electroquímicas , Humanos , Recién Nacido , Adhesividad Plaquetaria/efectos de los fármacos , Poliésteres/síntesis química , Poliésteres/farmacocinética , Ingeniería de Tejidos/instrumentación , Ingeniería de Tejidos/métodos , Andamios del Tejido/química
6.
Bioengineering (Basel) ; 10(5)2023 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-37237637

RESUMEN

Material extrusion (MEX), commonly referred to as fused deposition modeling (FDM) or fused filament fabrication (FFF), is a versatile and cost-effective technique to fabricate suitable scaffolds for tissue engineering. Driven by a computer-aided design input, specific patterns can be easily collected in an extremely reproducible and repeatable process. Referring to possible skeletal affections, 3D-printed scaffolds can support tissue regeneration of large bone defects with complex geometries, an open major clinical challenge. In this study, polylactic acid scaffolds were printed resembling trabecular bone microarchitecture in order to deal with morphologically biomimetic features to potentially enhance the biological outcome. Three models with different pore sizes (i.e., 500, 600, and 700 µm) were prepared and evaluated by means of micro-computed tomography. The biological assessment was carried out seeding SAOS-2 cells, a bone-like cell model, on the scaffolds, which showed excellent biocompatibility, bioactivity, and osteoinductivity. The model with larger pores, characterized by improved osteoconductive properties and protein adsorption rate, was further investigated as a potential platform for bone-tissue engineering, evaluating the paracrine activity of human mesenchymal stem cells. The reported findings demonstrate that the designed microarchitecture, better mimicking the natural bone extracellular matrix, favors a greater bioactivity and can be thus regarded as an interesting option for bone-tissue engineering.

7.
Biology (Basel) ; 12(3)2023 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-36979116

RESUMEN

Large bone defect treatments have always been one of the important challenges in clinical practice and created a huge demand for more efficacious regenerative approaches. The bone tissue engineering (BTE) approach offered a new alternative to conventional bone grafts, addressing all clinical needs. Over the past years, BTE research is focused on the study and realisation of new biomaterials, including 3D-printed supports to improve mechanical, structural and biological properties. Among these, polylactic acid (PLA) scaffolds have been considered the most promising biomaterials due to their good biocompatibility, non-toxic biodegradability and bioresorbability. In this work, we evaluated the physiological response of human foetal osteoblast cells (hFOB), in terms of cell proliferation and osteogenic differentiation, within oxygen plasma treated 3D-printed PLA scaffolds, obtained by fused deposition modelling (FDM). A mechanical simulation to predict their behaviour to traction, flexural or torque solicitations was performed. We found that: 1. hFOB cells adhere and grow on scaffold surfaces; 2. hFOB grown on oxygen plasma treated PLA scaffolds (PLA_PT) show an improvement of cell adhesion and proliferation, compared to not-plasma treated scaffolds (PLA_NT); 3. Over time, hFOB penetrate along strands, differentiate, and form a fibrous matrix, tissue-like; 4. 3D-printed PLA scaffolds have good mechanical behaviour in each analysed configuration. These findings suggest that 3D-printed PLA scaffolds could represent promising biomaterials for medical implantable devices in the orthopaedic field.

8.
Biomacromolecules ; 13(5): 1350-60, 2012 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-22449037

RESUMEN

In this study, we investigated whether multipotent (human-bone-marrow-derived mesenchymal stem cells [hBM-MSCs]) and pluripotent stem cells (murine-induced pluripotent stem cells [iPSCs] and murine embryonic stem cells [ESCs]) respond to nanocomposite fibrous mats of poly(L-lactic acid) (PLLA) loaded with 1 or 8 wt % of calcium-deficient nanohydroxyapatite (d-HAp). Remarkably, the dispersion of different amounts of d-HAp to PLLA produced a set of materials (PLLA/d-HAp) with similar architectures and tunable mechanical properties. After 3 weeks of culture in the absence of soluble osteogenic factors, we observed the expression of osteogenic markers, including the deposition of bone matrix proteins, in multi/pluripotent cells only grown on PLLA/d-HAp nanocomposites, whereas the osteogenic differentiation was absent on stem-cell-neat PLLA cultures. Interestingly, this phenomenon was confined only in hBM-MSCs, murine iPSCs, and ESCs grown on direct contact with the PLLA/d-HAp mats. Altogether, these results indicate that the osteogenic differentiation effect of these electrospun PLLA/d-HAp nanocomposites was independent of the stem cell type and highlight the direct interaction of stem cell-polymeric nanocomposite and the mechanical properties acquired by the PLLA/d-HAp nanocomposites as key steps for the differentiation process.


Asunto(s)
Calcio/química , Células Madre Embrionarias/química , Ácido Láctico/química , Células Madre Mesenquimatosas/química , Nanocompuestos/química , Células Madre Pluripotentes/química , Polímeros/química , Animales , Supervivencia Celular , Durapatita/química , Electroquímica , Células Madre Embrionarias/citología , Humanos , Células Madre Mesenquimatosas/citología , Ratones , Tamaño de la Partícula , Células Madre Pluripotentes/citología , Poliésteres
9.
J Mater Sci Mater Med ; 23(10): 2553-62, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22802105

RESUMEN

Magnesium alloys represent a valuable option for the production of bioresorbable implantable medical devices aimed to improve the therapeutic approach and minimize the potential risks related to biostable materials. In this regard, the degradation process needs to be carefully evaluated in order to assess the effectiveness of the regenerative support and the eventual toxic effects induced by the released corrosion products. Aluminium is one of the most common alloying element that raised several safety concerns, contributing to shift the investigation toward Al-free alloys. To delve into this issue, a long-term investigation (up to 28 days) was performed using AZ91D alloy, due to its relevant Al content. Immersion tests in phosphate buffered saline (PBS) solution was performed following the ASTM standards and the corrosion behaviour was evaluated at fixed time points by means of electrochemical techniques. Cytotoxic effects were assessed by culturing human neuroblastoma cells with conditioned medium derived from immersion tests at different dilution degree. An increase in the resistance corrosion with the time was observed. In all the investigated cases the presence of Al in the conditioned media did not induce significant toxic effects directly correlated to its content. A decrease of cell viability was only observed in the case of 50 % dilution of PBS conditioned for the longest immersion period (i.e., 28 days).


Asunto(s)
Aleaciones , Materiales Biocompatibles , Corrosión , Magnesio/química , Línea Celular Tumoral , Técnicas Electroquímicas , Humanos , Técnicas In Vitro , Microscopía Electrónica de Rastreo , Difracción de Rayos X
10.
NPJ Microgravity ; 8(1): 45, 2022 Oct 29.
Artículo en Inglés | MEDLINE | ID: mdl-36309540

RESUMEN

One of humanity's greatest challenges is space exploration, which requires an in-depth analysis of the data continuously collected as a necessary input to fill technological gaps and move forward in several research sectors. Focusing on space crew healthcare, a critical issue to be addressed is tissue regeneration in extreme conditions. In general, it represents one of the hottest and most compelling goals of the scientific community and the development of suitable therapeutic strategies for the space environment is an urgent need for the safe planning of future long-term manned space missions. Osteopenia is a commonly diagnosed disease in astronauts due to the physiological adaptation to altered gravity conditions. In order to find specific solutions to bone damage in a reduced gravity environment, bone tissue engineering is gaining a growing interest. With the aim to critically investigate this topic, the here presented review reports and discusses bone tissue engineering scenarios in microgravity, from scaffolding to bioreactors. The literature analysis allowed to underline several key points, such as the need for (i) biomimetic composite scaffolds to better mimic the natural microarchitecture of bone tissue, (ii) uniform simulated microgravity levels for standardized experimental protocols to expose biological materials to the same testing conditions, and (iii) improved access to real microgravity for scientific research projects, supported by the so-called democratization of space.

11.
Artículo en Inglés | MEDLINE | ID: mdl-33573007

RESUMEN

Recent works have demonstrated that particulate matter (PM) and specific meteorological conditions played an important role in the airborne transmission of the SARS-CoV-1 and MERS-CoV. These studies suggest that these parameters could influence the transmission of SARS-CoV-2. In the present investigation, we sought to investigate the association between air pollution, meteorological data, and the Lombardy region COVID-19 outbreak caused by SARS-CoV-2. We considered the number of detected infected people at the regional and provincial scale from February to March 2020. Air pollution data were collected over the Lombardy region, nominally, sulphur dioxide, ammonia, nitrogen dioxide, nitrogen monoxide, carbon monoxide, ozone, and suspended particulate matter measuring less than 10 µm (PM10) and less than 2.5 µm (PM2.5). Meteorological data have been collected over the same region for temperature, relative humidity, and wind speed. In this work, we evaluated the combined impact of environmental pollutants and climate conditions on the COVID-19 outbreak. The analysis evidenced a positive correlation between spatial distribution of COVID-19 infection cases with high concentrations of suspended particulate matter and a negative relationship with ozone. Moreover, suspended particulate matter concentration peaks in February correlated positively with infection peaks according to the virus incubation period. The obtained results suggested that seasonal weather conditions and concentration of air pollutants seemed to influence COVID-19 epidemics in Lombardy region.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire , COVID-19/transmisión , Material Particulado , Contaminantes Atmosféricos/análisis , Contaminación del Aire/análisis , COVID-19/epidemiología , Monitoreo del Ambiente , Humanos , Italia/epidemiología , Material Particulado/análisis
12.
J Mater Sci Mater Med ; 21(4): 1353-62, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19957022

RESUMEN

This work focuses on the evaluation of the potential use of electrospun poly(epsilon-caprolactone) (PCL) micrometric and/or sub-micrometric fibrous membranes for rat hippocampal astrocyte (HA) and rat cerebro-microvascular endothelial cell (CEC) cultures. Both mats supported cell adhesion, proliferation, cellular phenotype and spreading. Microfibrous mats allowed cellular infiltration, while both HAs and CECs were unable to migrate within the sub-micrometric fibrous mat, leaving an acellularized inner region. This finding was correlated to the presence of larger voids within electrospun PCL microfibrous mats, suggesting that the morphology should be accurately selected for the realization of a cell environment-mimicking mat. Based on our results, the proper fiber architecture can be regarded as a crucial issue to be considered in order to deal with suitable polymeric mats tailored for specific in vitro application.


Asunto(s)
Astrocitos/efectos de los fármacos , Cerebro/efectos de los fármacos , Células Endoteliales/efectos de los fármacos , Membranas Artificiales , Poliésteres/farmacología , Animales , Animales Recién Nacidos , Astrocitos/fisiología , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología , Células Cultivadas , Cerebro/citología , Cerebro/fisiología , Electroquímica/métodos , Células Endoteliales/fisiología , Ensayo de Materiales , Nanofibras/química , Nanotecnología/métodos , Poliésteres/química , Ratas , Ratas Sprague-Dawley , Ingeniería de Tejidos/métodos , Andamios del Tejido/química
13.
Int J Artif Organs ; 33(5): 271-82, 2010 May.
Artículo en Inglés | MEDLINE | ID: mdl-20593348

RESUMEN

Carbon nanostructures (CNSs) are attractive and promising nanomaterials for the next generation of tissue engineering scaffolds, especially in neural prosthesis. Optimizing scaffold vascularization may be an important strategy to promote the repair of damaged brain tissue. In this context, the idea was to evaluate the cell response of electrospun nanohybrid scaffolds loaded with CNSs. Fibrous composites based on poly(epsilon-caprolactone) (PCL) and CNSs were fabricated by means of electrospinning technique. High-purity carbon nanofibers (CNFs) and single-wall carbon nanotubes (SWNTs) were studied. A detailed microstructural characterization was performed to evaluate the most favorable experimental conditions for the realization of fibrous PCL/CNS fabrics. Electrospun mats comprised of rather uniform and homogeneous submicrometric fibers were obtained starting from 1:1 v/v mixture of tetrahydrofuran (THF) and N,N dimethylformamide (DMF). In vitro cytocompatibility tests were performed using rat cerebro-microvascular endothelial cells (CECs). Acquired results showed an increased cell viability for PCL/CNS nanocomposites, suggesting these materials as a suitable environment for endothelial cells. These results are indicative of the promising potential of CNS-based nanocomposites in biomedical devices for tissue engineering applications where endothelial functional properties are required.


Asunto(s)
Encéfalo/irrigación sanguínea , Células Endoteliales/fisiología , Nanocompuestos , Nanofibras , Nanotubos de Carbono/química , Poliésteres/química , Ingeniería de Tejidos/instrumentación , Andamios del Tejido , Animales , Animales Recién Nacidos , Rastreo Diferencial de Calorimetría , Forma de la Célula , Supervivencia Celular , Células Cultivadas , Microscopía Electrónica de Rastreo , Microvasos/citología , Microvasos/fisiología , Diseño de Prótesis , Ratas , Ratas Sprague-Dawley , Espectrometría Raman , Propiedades de Superficie
14.
J Mech Behav Biomed Mater ; 103: 103583, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32090912

RESUMEN

Additive manufacturing for tissue engineering applications offers the possibility to design scaffolds characterized by a fine and detailed microarchitecture. Several fabrication technologies are currently available which allow to prepare tailored structures with a large selection of materials for restoring and healing tissues. However, 3D printed scaffolds are generally collected by assembling repetitive geometrical units or reproducing specific patterns in the layering direction, leading to a highly ordered architecture that does not mimic the morphology of the natural extracellular matrix (ECM), one of the main goals to be reached for an effective therapeutic approach. It is usually stated in the tissue engineering field that a scaffold has to be considered a temporary ECM, resembling all the peculiar features as close as possible and, in this regard, an ordered microstructure cannot be usually observed within biological tissues and organs. With the aim to overcame this limitation and offer a potential approach for bone tissue applications, the present study proposes a design methodology to fabricate 3D printed scaffolds characterized by a random microarchitecture which can be repeatedly reproduced thanks to the intrinsic controllable process of additive manufacturing. In this framework, four different models in polylactic acid were fabricated by means of fused deposition modelling, including a three-dimensional random distribution of spherical pores of 400, 500, and 600 µm for the first three cases, and a randomly varied distribution in the range 400-600 µm for the fourth case. A detailed assessment by means of microcomputed tomography and mechanical evaluation was then carried out in order to fully analyse the resulting scaffolds, providing both morphological and quantitative data.


Asunto(s)
Ingeniería de Tejidos , Andamios del Tejido , Huesos , Impresión Tridimensional , Microtomografía por Rayos X
15.
Nanomaterials (Basel) ; 10(10)2020 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-33049913

RESUMEN

Severe muscle injuries are a real clinical issue that still needs to be successfully addressed. Tissue engineering can represent a potential approach for this aim, but effective healing solutions have not been developed yet. In this regard, novel experimental protocols tailored to a biomimetic approach can thus be defined by properly systematizing the findings acquired so far in the biomaterials and scaffold manufacturing fields. In order to plan a more comprehensive strategy, the extracellular matrix (ECM), with its properties stimulating neomyogenesis and vascularization, should be considered as a valuable biomaterial to be used to fabricate the tissue-specific three-dimensional structure of interest. The skeletal muscle decellularized ECM can be processed and printed, e.g., by means of stereolithography, to prepare bioactive and biomimetic 3D scaffolds, including both biochemical and topographical features specifically oriented to skeletal muscle regenerative applications. This paper aims to focus on the skeletal muscle tissue engineering sector, suggesting a possible approach to develop instructive scaffolds for a guided healing process.

16.
Biomed Res Int ; 2020: 2689701, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33282941

RESUMEN

Functional engineered muscles are still a critical clinical issue to be addressed, although different strategies have been considered so far for the treatment of severe muscular injuries. Indeed, the regenerative capacity of skeletal muscle (SM) results inadequate for large-scale defects, and currently, SM reconstruction remains a complex and unsolved task. For this aim, tissue engineered muscles should provide a proper biomimetic extracellular matrix (ECM) alternative, characterized by an aligned/microtopographical structure and a myogenic microenvironment, in order to promote muscle regeneration. As a consequence, both materials and fabrication techniques play a key role to plan an effective therapeutic approach. Tissue-specific decellularized ECM (dECM) seems to be one of the most promising material to support muscle regeneration and repair. 3D printing technologies, on the other side, enable the fabrication of scaffolds with a fine and detailed microarchitecture and patient-specific implants with high structural complexity. To identify innovative biomimetic solutions to develop engineered muscular constructs for the treatment of SM loss, the more recent (last 5 years) reports focused on SM dECM-based scaffolds and 3D printing technologies for SM regeneration are herein reviewed. Possible design inputs for 3D printed SM dECM-based scaffolds for muscular regeneration are also suggested.


Asunto(s)
Materiales Biomiméticos/química , Matriz Extracelular/metabolismo , Músculo Esquelético/fisiología , Impresión Tridimensional , Ingeniería de Tejidos , Andamios del Tejido/química , Animales , Humanos
17.
J Healthc Eng ; 2019: 2815789, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31183028

RESUMEN

Raman spectroscopy is a powerful optical technique based on the inelastic scattering of incident light to assess the chemical composition of a sample, including biological ones. Medical diagnostic applications of Raman spectroscopy are constantly increasing to provide biochemical and structural information on several specimens, being not affected by water interference, and potentially avoiding the constraint of additional labelling procedures. New strategies have been recently developed to overcome some Raman limitations related, for instance, to the need to deal with an adequate quantity of the sample to perform a reliable analysis. In this regard, the use of metallic nanoparticles, the optimization of fiber optic probes, and other approaches can actually enhance the signal intensity compared to spontaneous Raman scattering. Moreover, to further increase the potential of this investigation technique, aptamers can be considered as a valuable means, being synthetic, short, single, or double-stranded oligonucleotides (RNAs or DNAs) that fold up into unique 3D structures to specifically bind to selected molecules, even at very low concentrations, and thus allowing an early diagnosis of a possible disease. Due to the paramount relevance of the topic, this review focuses on the main Raman spectroscopy techniques combined with aptamer arrays in the label-free mode, providing an overview on different applications to support healthcare management.


Asunto(s)
Aptámeros de Nucleótidos , Diagnóstico por Imagen , Espectrometría Raman , Humanos , Nanopartículas del Metal
19.
J Biomech ; 41(11): 2539-50, 2008 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-18579146

RESUMEN

The main purpose of this study is to reproduce in silico the dynamics of a bileaflet mechanical heart valve (MHV; St Jude Hemodynamic Plus, 27mm characteristic size) by means of a fully implicit fluid-structure interaction (FSI) method, and experimentally validate the results using an ultrafast cinematographic technique. The computational model was constructed to realistically reproduce the boundary condition (72 beats per minute (bpm), cardiac output 4.5l/min) and the geometry of the experimental setup, including the valve housing and the hinge configuration. The simulation was carried out coupling a commercial computational fluid dynamics (CFD) package based on finite-volume method with user-defined code for solving the structural domain, and exploiting the parallel performance of the whole numerical setup. Outputs are leaflets excursion from opening to closure and the fluid dynamics through the valve. Results put in evidence a favorable comparison between the computed and the experimental data: the model captures the main features of the leaflet motion during the systole. The use of parallel computing drastically limited the computational costs, showing a linear scaling on 16 processors (despite the massive use of user-defined subroutines to manage the FSI process). The favorable agreement obtained between in vitro and in silico results of the leaflet displacements confirms the consistency of the numerical method used, and candidates the application of FSI models to become a major tool to optimize the MHV design and eventually provides useful information to surgeons.


Asunto(s)
Simulación por Computador , Prótesis Valvulares Cardíacas , Velocidad del Flujo Sanguíneo/fisiología
20.
Ann Ist Super Sanita ; 44(2): 178-86, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18660567

RESUMEN

SUMMARY: Currently implanted prosthetic heart valves, both mechanical or biological ones, are used to restore the proper blood hemodynamics when the native valves fail. However, these medical devices are not free from drawbacks, such as hemolysis or calcification, also presenting the relevant disadvantage of being unable to growth, repair and remodel. An improvement could be represented by bioresorbable polymeric tissue-engineered heart valves. In this paper a poly(epsilon -caprolactone) (PCL) heart valve prosthesis, realized by means of electrospinning, and its in vitro functional characterization in a pulse duplicator, resembling pulmonary conditions, is presented. Morphological examination revealed polymeric micrometric fibers randomly oriented with an average porosity of about 90 percent. Pulse duplicator testing highlighted that leaflets opened synchronously and showed a correct coaptation in the diastolic phase, even if a slight rotation of the leaflets was visualized. In silico study by numerical simulation of the closed phase predicted the stress distribution within the leaflet, showing that peak levels are reached at the commissures and sustained by the structure without failure. The present study highlighted the technical feasibility to produce polymeric bioresorbable functional heart valves by means of electrospinning. Further studies and design changes are needed in order to optimize the final scaffold to bear arterial hemodynamic conditions.


Asunto(s)
Materiales Biocompatibles , Prótesis Valvulares Cardíacas , Válvula Pulmonar/fisiología , Algoritmos , Diseño de Equipo , Humanos , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Poliésteres , Ingeniería de Tejidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA