BMC Oral Health ; 21(1): 33, 2021 01 19.
Artículo en Inglés | MEDLINE | ID: mdl-33468122

RESUMEN

BACKGROUND: Adhesive restorations allow a conservative approach to caries management and are increasingly used as a restorative option in pediatric dentistry. Placement can be difficult in children because of the cooperation required for multiple bonding steps. Due to this, it is vital to assess if novel, simpler strategies have been featured in clinical trials and if clinical trials are researching the different existing adhesive strategies. METHODS: This review followed Preferred Reporting Items for Systematic Reviews and Meta-analysis adapted for Scoping Reviews (PRISMA-ScR) guidelines. PubMed/Medline, Cochrane Central, Scopus and EMBASE were used for systematic search, using free keywords and controlled search terms. Clinical trials of children requiring a restorative intervention which featured adhesive strategies were included. Only peer-reviewed trials of primary teeth restored with resin composites, published in the last 10-year period were eligible. Data charting was accomplished independently by two reviewers, and studies were summarized according to their date, type, intervention, sample size, observation period, outcomes and conclusions. Quality assessment was performed using Cochrane's Risk of Bias 2.0 tool. RESULTS: 700 potentially relevant references were found, which after a rigorous inclusion scheme, resulted in a total of 8 eligible clinical trials. Out of these, 7 were randomized clinical trials. Most trials featured a split-mouth design and the observation period ranged from 12 to 36 months. The trials evaluated interventions of two self-adhesive composites, two bulk-fill composites, two novel composites, one compomer and eight adhesives from different strategies. Most studies (4/8) included were judged to raise some concerns regarding risk of bias, while two were classified as high risk and two as low. CONCLUSION: Few studies comparing adhesive strategies were found, especially adhesives in sound substrates. The existing studies do not reflect all current approaches that could be used in pediatric dentistry. Further studies addressing bioactive composites and contemporary adhesives are necessary.


Asunto(s)
Caries Dental , Odontología Pediátrica , Niño , Resinas Compuestas , Caries Dental/terapia , Cementos Dentales , Humanos , Diente Primario
2.
Pharmaceutics ; 16(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38794276

RESUMEN

Ozone is increasingly utilized in dental caries treatment due to its antibacterial properties. In a context of limited studies and no consensus on protocols, this research aims to assess ozone's antibacterial efficacy on cariogenic bacteria and its potential adverse impact on dentin bond strength. Streptococcus mutans, Streptococcus sobrinus, Lactobacillus casei, and Actinomyces naeslundii suspensions were exposed to 40 µg/mL of ozone gas and 60 µg/mL of ozonated water (80 s) via a medical ozone generator. Negative and positive control groups (chlorhexidine 2%) were included, and UFC/mL counts were recorded. To examine microtensile bond strength (µTBS), 20 human molars were divided into four groups, and class I cavities were created. After ozone application, samples were restored using an etch-and-rinse and resin composite, then sectioned for testing. The SPSS v. 28 program was used with a significance level of 5%. The µTBS results were evaluated using one-way ANOVA, Tukey HSD, and Games-Howell. Bacterial counts reduced from 106 to 101, but dentin µTBS was significantly impacted by ozone (ANOVA, p < 0.001). Despite ozone's attractive antibacterial activity, this study emphasizes its detrimental effect on dentin adhesion, cautioning against its use before restorative treatments.

3.
Biomedicines ; 10(12)2022 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-36551861

RESUMEN

This study aimed to assess whether degradation-resistant monomers included in experimental dental adhesives can improve long-term bond strength compared to conventional monomers. This study followed the latest PRISMA guidance (2020). The search for the systematic review was carried out in four electronic databases: PubMed/Medline, Scopus, SciELO and EMBASE, without restrictions on the year of publication and language. The last screening was conducted in July 2022. Interventions included were in vitro studies on experimental dental adhesives that tested short-term and long-term bond strength, but also water sorption and solubility data when available, in extracted human molars. Meta-analyses were performed using Rstudio v1.4.1106. A summary table analyzing the individual risk of bias was generated using the recent RoBDEMAT tool. Of the 177 potentially eligible studies, a total of 7 studies were included. Experimental monomers with acrylamides or methacrylamide−acrylamide hybrids in their composition showed better results of aged bond strength when compared to methacrylate controls (p < 0.05). The experimental monomers found better sorption and solubility compared to controls and were significantly different (p < 0.001). It is possible to achieve hydrolytically resistant formulations by adding novel experimental monomers, with chemical structures that bring benefit to degradation mechanisms.

4.
Polymers (Basel) ; 14(7)2022 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-35406335

RESUMEN

A vast number of adhesive formulations exist currently. However, available adhesives still have several drawbacks such as increased hydrophilicity, polymerization deficiency, potential cytotoxicity and limited monomer interdiffusion within dentin. To improve material properties, a Bisphenol A-free adhesive containing a novel dendrimer G(2)-isocyanatoethyl methacrylate (G-IEMA) in replacement of Bis-GMA was made and tested. Sound human molars were sectioned to expose mid-coronal dentin, which was bonded using four adhesives­Futurabond, Scotchbond Universal and experimentals EM1 and EM2. The experimental adhesive EM2 contained G-IEMA, while EM1 had Bis-GMA. Groups were further allocated to two different adhesive strategies: etch-and-rinse (20 s etching) or self-etch. Immediate (24 h) microtensile bond strength to dentin (n = 5) was tested using a universal testing machine (1 mm/min, 5 kN; Shimadzu AGS-X Autograph, Tokyo, Japan), while the ultrastructure of the interface (n = 2) was assessed using scanning electron microscopy-energy dispersive spectroscopy (SEM-EDS). Nanoleakage expression was evaluated using silver nitrate penetration and posterior SEM-EDS analysis (n = 3). Linear mixed models/Generalized models were used for inferential statistics (5% significance level). Bond strength results did not depend on the adhesive choice, although differences were found between strategies (p < 0.001). Regarding nanoleakage, when applied in an etch-and-rinse mode, experimental adhesives scored lower nanoleakage means than Futurabond and Scotchbond Universal. The novel adhesive shows interesting interfacial properties, with favorable nanoleakage results and a bond strength to dentin that matches current commercial adhesives.

5.
Polymers (Basel) ; 14(19)2022 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-36235894

RESUMEN

The aim of this study is to compare the adhesive interface formed in dentin, using self-adhesive composites applied with different bonding strategies, by testing the microtensile bond strength (µTBS) and ultramorphology through the use of light microscopy. Permanent, sound human molars were randomly allocated to six experimental groups. The groups included a negative control group, where only etching was performed via EtchOnly; a positive control group where an adhesive was applied, OptiBondFL (OBFL); and an experimental group where a primer was applied using a co-curing strategy together with a composite (Primer_CoCuring). The samples were sectioned into microspecimens for µTBS (n = 8) and into 1-mm thick slabs for light microscopy using Masson's trichrome staining protocol (n = 3). The statistical analysis included a two-way ANOVA for µTBS data and Tukey's HSD was used as a post-hoc test (significance level of 5%; SPSS v. 26.0). The results of the µTBS revealed that the self-adhesive composite (F = 6.0, p < 0.018) and the bonding strategy (F = 444.1, p < 0.001) significantly affected the bond strength to dentin. However, their interactions were not significant (F = 1.2, p = 0.29). Etching dentin with no additional treatment revealed the lowest µTBS (VF_EtchOnly = 2.4 ± 0.8 MPa; CC_EtchOnly = 2.0 ± 0.4 MPa), which was significantly different from using a primer (VF_CoCu = 8.8 ± 0.8 MPa; CC_CoCu = 6.3 ± 1.0 MPa) or using the full adhesive (VF_OptiBondFL = 22.4 ± 0.3 MPa; CC_OptibondFL = 21.2 ± 0.4 MPa). Microscopy images revealed that the experimental Primer_CoCuring was the only group with no collagen fibers exposed to the dentin−composite interface. Overall, the use of a primer, within the limitations of this study, increased the bonding of the self-adhesive composite and provided sufficient infiltration of the collagen based on light-microscopic imaging.

6.
Dent Mater ; 38(2): 333-346, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34955234

RESUMEN

OBJECTIVE: Acrylic acid derivatives are frequently used as dental monomers and their cytotoxicity towards various cell lines is well documented. This study aims to probe the structural and physicochemical attributes responsible for higher toxicity of dental monomers, using quantitative structure-activity relationships (QSAR) modeling approaches. METHODS: A regression-based linear single-target QSAR (st-QSAR) model was developed with a comparatively small dataset containing 39 compounds, the cytotoxicity of which has been assessed over the Hela S3 cell line. By contrast, a classification-based multi-target QSAR model was developed with 138 compounds, the cytotoxicity of which has been reported against 18 different cell lines. Both models were set up following rigorous validation protocols confirming their statistical significance and robustness. RESULTS: The performance of the linear mt-QSAR model, developed with various feature selection and post-selection similarity searching-based schemes, superseded that of all non-linear models produced with six machine learning methods by hyperparameter optimization. The final derived st-QSAR and mt-QSAR linear models are shown to be highly predictive, as well as revealing the crucial structural and physicochemical factors responsible for higher cytotoxicity of the dental monomers. SIGNIFICANCE: This study is the first attempt on unveiling the cytotoxicity of dental monomers over several cell lines by means of a single multi-target QSAR model. Further, such a model is ready to get widespread applicability in the screening of new monomers, judging from its almost accurate predictions over diverse experimental assay conditions.


Asunto(s)
Relación Estructura-Actividad Cuantitativa , Acrilatos
7.
Materials (Basel) ; 15(6)2022 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-35329495

RESUMEN

There is still a lack of consensus concerning the recommended etching concentration, application time and type of silane when bonding lithium disilicate-reinforced glass ceramics manufactured by CAD/CAM. The purpose of this study was thus to conduct an in vitro study which investigates the influence of hydrofluoric acid (HF) concentration, etching time and silane type on the microtensile bond strength (µTBS) of lithium disilicate to resin composites. Thirty-nine IPS e.max CAD blocks were randomly divided between thirteen groups (n = 3). The variables were HF concentration (9.5 or 4.9%), etching time (20 or 60 s) and silane type (Bis-Silane, Monobond Plus and ESPE Sil Silane). The blocks were cut into beams, aged for 10,000 cycles in a thermocycler and submitted to tensile stress to determine µTBS. A control group featuring the Monobond Etch & Prime (MEP) agent that combines etching/silanisation into a simultaneous process was also added. This group was discarded from the analysis due to only having pre-test failures. The data were analysed using a three-way ANOVA (α = 0.05). The HF concentration, etching time and silane type significantly influenced µTBS (p < 0.001). Significant interactions between time and silane type (p = 0.004), HF concentration and silane type (p < 0.001) and among the three factors (p < 0.001) were noted. Etching lithium disilicate with 9.5% HF (60 s), followed by the application of Bis-Silane, resulted in the highest µTBS (16.6 ± 9.0 MPa). The highest concentration and etching time under study, combined with a two-part silane, resulted in the highest bond strength, while the application of MEP showed a complete pre-test failure.

8.
PLoS One ; 16(6): e0252999, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34106972

RESUMEN

Investigation of polymerisation kinetics using ATR-FTIR systems is common in many dental studies. However, peak selection methods to calculate monomer-polymer conversion can vary, consequently affecting final results. Thus, the aim of this study is to experimentally confirm which method is less prone to systematic errors. Three commercial restorative materials were tested-Vertise Flow (VF), Constic and Activa Bioactive Restorative Kids. Firstly, Attenuated Total Reflectance Fourier Transform Infra-Red (ATR-FTIR) (Spectrum One, Perkin-Elmer, UK) spectra of monomers were acquired-10-methacryloyloxy decyl dihydrogen phosphate (10-MDP), bisphenol-A glycidyl dimethacrylate (Bis-GMA), 2-hydroxyethyl methacrylate (HEMA), triethyelene glycol dimethacrylate (TEGDMA) and urethane dimethacrylate (UDMA) to investigate proportionality of methacrylate peak heights versus concentration. Spectral changes upon light exposure of 2 mm discs of the restorative materials (irradiated for 20 s, LED curing unit 1100-1330 mW/cm2) were assessed to study polymerisation kinetics (n = 3), with continuous acquisition of spectra, before, during and after light exposure. Peak differences and degrees of conversion (DC %) were calculated using 1320/1336, 1320/1350 and 1636/1648 cm-1 as reaction/reference peaks. Inferential statistics included a MANOVA and within-subjects repeated measures ANOVA design (5% significance level). Proportionality of methacrylate peak height to concentration was confirmed, with the 1320/1352 cm-1 peak combination showing the lowest coefficient of variation (8%). Difference spectra of the polymerisation reaction showed noise interference around the 1500-1800 cm-1 region. Across the different materials, DC % results are highly dependent upon peak selection (p<0.001), with higher variability associated to the 1636 cm-1. Significant differences in the materials were only detected when the 1320 cm-1 peak was used (p<0.05). Within the same materials, methods were significantly different for Constic and Activa (p<0.05). It is possible to conclude that the 1320 cm-1 peak is more adequate to assess polymerisation of methacrylates and is therefore recommended.


Asunto(s)
Materiales Biocompatibles/análisis , Materiales Dentales/análisis , Ensayo de Materiales/métodos , Metacrilatos/análisis , Polimerizacion , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Materiales Biocompatibles/química , Materiales Dentales/química , Humanos , Metacrilatos/química
9.
Dent Mater ; 37(9): 1366-1376, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34144796

RESUMEN

OBJECTIVES: To assess the influence of systematically varying concentrations of 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) versus 3% 4-META on the polymerisation kinetics and shrinkage, biaxial flexural strength (BFS) and modulus of remineralising composites. METHODS: Composites were prepared by adding poly(propylene glycol) dimethacrylate (24 wt%), camphorquinone (1 wt%) and MDP (0%, 5%, 10%, 15% and 20 wt%) or 4-META (3%) to urethane dimethacrylate. These were mixed with glass fillers containing 8 wt% monocalcium phosphate and 4 wt% polylysine (powder-liquid ratio of 3:1). Continuous spectral changes, following 20 s light exposure (37 °C), were assessed with an ATR-FTIR to monitor polymerisation kinetics (n = 3). Final extrapolated conversions (DC,max) were employed to calculate polymerisation shrinkage. BFS and modulus of 24-h dry stored disc specimens (10 × 1 mm; n = 10) were determined using a ball-on-ring jig setup. RESULTS: Maximum rate of polymerisation and DC,max increased linearly from 2.5 to 3.5% s-1 and 67 to 83%, respectively, upon increasing MDP from 0 to 20 wt%. Values with 3% 4-META were 2.6% s-1 and 78%. Shrinkage was 3.8 ± 0.3% for all formulations. Raising 4-META or MDP from 0 to 3 versus 5%, respectively, increased strength from 106 to 145 versus 136 MPa. A decreasing trend with higher MDP concentrations was noted. Elastic modulus showed no specific trend upon MDP increase. SIGNIFICANCE: Whilst final conversion levels were enhanced by 3% 4-META or >5% MDP, trends did not correlate with strength. Peak strengths with 3% 4-META or 5% MDP may therefore be due to acidic monomers providing linkage between the hydrophilic, non-silane treated particles and the polymer matrix.


Asunto(s)
Resistencia Flexional , Cementos de Resina , Resinas Compuestas , Cementos Dentales , Cinética , Ensayo de Materiales , Metacrilatos , Propiedades de Superficie
10.
Polymers (Basel) ; 13(22)2021 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-34833185

RESUMEN

The of this study aim was to develop a rapid method to determine the chemical composition, solvent evaporation rates, and polymerization kinetics of dental adhesives. Single-component, acetone-containing adhesives One-Step (OS; Bisco, Anaheim, CA, USA), Optibond Universal (OU; Kerr, Brea, CA, USA), and G-Bond (GB; GC, Tokyo, Japan) were studied. Filler levels were determined gravimetrically. Monomers and solvents were quantified by comparing their pure Attenuated Total Reflectance-Fourier Transform Infra-Red (ATR-FTIR) spectra, summed in different ratios, with those of the adhesives. Spectral changes at 37 °C, throughout passive evaporation for 5 min, then polymerisation initiated by 20 s, and blue light emitting diode (LED) (600 mW/cm2) exposure (n = 3) were determined. Evaporation and polymerisation extent versus time and final changes were calculated using acetone (1360 cm-1) and methacrylate (1320 cm-1) peaks. OS, OU, and GB filler contents were 0, 9.6, and 5.3%. FTIR suggested OS and OU were Bis-GMA based, GB was urethane dimethacrylate (UDMA) based, and that each had a different diluent and acidic monomers and possible UDMA/acetone interactions. Furthermore, initial acetone percentages were all 40-50%. After 5 min drying, they were 0% for OS and OU but 10% for GB. Whilst OS had no water, that in OU declined from 18 to 10% and in GB from 25 to 20% upon drying. Evaporation extents were 50% of final levels at 23, 25, and 113 s for OS, OU, and GB, respectively. Polymerisation extents were all 50 and 80% of final levels before 10 and at 20 s of light exposure, respectively. Final monomer polymerisation levels were 68, 69, and 88% for OS, OU, and GB, respectively. An appreciation of initial and final adhesive chemistry is important for understanding the properties. The rates of evaporation and polymerisation provide indications of relative required drying and light cure times. UDMA/acetone interactions might explain the considerably greater drying time of GB.

11.
Biomater Investig Dent ; 8(1): 24-38, 2021 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-33629074

RESUMEN

AIM: To summarize and report laboratory studies of adhesion in eroded substrates, which used bond strength as an outcome measure. To determine the strategies available to overcome bonding difficulties, the quality and consistency of the methodology and to find evidence gaps. MATERIALS AND METHODS: The present review followed PRISMA-ScR guidelines. A search was conducted on PubMed/Medline, Scopus and EMBASE (Ovid) databases to identify published peer-reviewed papers (2010-2020). For final qualitative synthesis, 29 articles were selected which respected the inclusion criteria. Data charting was carried out, independently, by two reviewers and quality assessment of the articles was performed. RESULTS: The primary studies included fall into four major categories: comparison of restorative materials and application modes, enzymatic inhibitors, surface pretreatments or remineralization strategies. Most studies found evaluated dentin (76%), while 17% evaluated enamel, and 7% evaluated both substrates. The majority of the studies reported an effective intervention (83%). Bond strength to eroded dentin is significantly reduced, while in enamel erosion is beneficial. The bond strength to eroded dentin is material-dependent and favored in systems containing 10-MDP. Great disparities among the erosion models used were found, with citric acid in different concentrations being the preferred method, although standardization is lacking. CONCLUSIONS: Adhesives containing 10-MDP show beneficial results in eroded dentin, and surface preparation methods should be considered. Studies which evaluated adhesion to eroded enamel/dentin show high heterogeneity in what concerns aims and methodology. Strategies that focus on remineralizing dentin and strategies to protect bond longevity in this substrate require further research.

12.
Contemp Clin Dent ; 9(3): 400-405, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30166834

RESUMEN

BACKGROUND: Conventional acrylic resin is prone to microbial colonization and may cause inflammatory and allergic response. AIMS: This study aims to research the initial microbial adhesion in situ and tissue response to an acrylic resin used in prosthodontics. MATERIALS AND METHODS: Disks of a commercial acrylic resin were prepared and included on the surface of individual intraoral splints fabricated for 50 participants. The splints were used for 4 h, under clinical conditions. Beforehand, each participant was swabbed to provide a control for microbiological comparison. A cytological control sample was also taken from the palate. After the time elapsed, each splint was removed and growth of anaerobes, aerobes, Pseudomonas, oral streptococci, staphylococci, yeasts, and Streptococcus mutans was determined by plate counts and compared to the oral microbiome. A cytological sample was taken from the contact zone, stained using the Papanicolaou technique, analyzed in light microscopy, and classified accordingly. Means and standard deviations were calculated, and a nonparametric Wilcoxon test was employed to compare experimental groups. The significance level was set at 0.05 (95% confidence interval, and statistical analysis was performed using Statistical Package for the Social Sciences (SPSS) version 20.0. RESULTS: Nuclear-cytoplasm ratio increase was found in 84% of the smears retrieved from the contact zone. Over 60% showed nuclear alterations. With exception to yeasts and Pseudomonas, all microbial groups colonized the resin. No statistically significant differences were found between the oral microbiome and the acrylic resin's colonization except regarding yeasts (P > 0.05). CONCLUSIONS: Cellular alterations were found but a diagnosis of inflammation is inconclusive. Microbial adhesion to the acrylic resin was substantial, with multiple species adhering.