Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
J Card Surg ; 36(8): 2949-2951, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33982331

RESUMEN

We describe the case of a 45-year-old man, with a history of blunt trauma to the chest 2 years back, presenting with diastolic dysfunction secondary to the development of a large, organized, intrapericardial hematoma. The case highlights the possibility of extremely delayed presentation in such cases and the importance of cardiac magnetic resonance imaging in making an accurate preoperative diagnosis and guiding optimal management strategies.


Asunto(s)
Hematoma , Heridas no Penetrantes , Hematoma/diagnóstico por imagen , Hematoma/etiología , Hematoma/cirugía , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Heridas no Penetrantes/complicaciones , Heridas no Penetrantes/diagnóstico por imagen
2.
J Card Surg ; 36(8): 2937-2938, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33896037

RESUMEN

We present an unusual case of an 18-day-old term neonate with coexistent bilateral bronchopulmonary vascular malformations and right isomerism. This case highlights the importance of computed tomography angiography in depicting such complex anomalies and classifying them according to components involved providing a systematic approach for evaluation of the disease process.


Asunto(s)
Síndrome de Heterotaxia , Malformaciones Vasculares , Angiografía , Síndrome de Heterotaxia/diagnóstico por imagen , Humanos , Recién Nacido , Isomerismo , Tomografía Computarizada por Rayos X , Malformaciones Vasculares/diagnóstico por imagen
4.
J Card Surg ; 35(11): 3141-3144, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32840923

RESUMEN

Paraneoplastic Pemphigus (PNP), a rare autoimmune blistering disease, can be accompanied by both benign and malignant neoplasms. The most frequently reported associated malignancies include lymphomatoid and hematologic malignancies, Castleman's disease, carcinoma, thymoma. In a patient suspected of PNP, with no known history of malignancy, an extensive workup is suggested to look for underlying malignancy, which has to be treated to induce PNP remission. In this clinical case report, cross sectional imaging of a young female diagnosed with PNP, unveiled a pericardial mass lesion extending into transverse pericardial sinus. Excisional biopsy was performed. Histopathology revealed pericardial ectopic thymoma.


Asunto(s)
Neoplasias Cardíacas/complicaciones , Neoplasias Cardíacas/diagnóstico por imagen , Síndromes Paraneoplásicos/etiología , Síndromes Paraneoplásicos/patología , Pénfigo/etiología , Pénfigo/patología , Pericardio/diagnóstico por imagen , Timoma/complicaciones , Timoma/diagnóstico por imagen , Adulto , Imagen de Difusión por Resonancia Magnética , Femenino , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones
8.
Br J Radiol ; 95(1129): 20210878, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-34591649

RESUMEN

Periaortic air can be seen in various conditions which can be a benign imaging finding or harbinger of a catastrophic event. The causes vary in native aorta and post-operative aorta. A radiologist has an important part in the management process of these patients, as the treatment varies from conservative to radical surgery based on the aetiology. The presence of periaortic air seen in the light of various clinical, laboratory and radiological findings can guide the radiologist towards a particular aetiology. Cross-sectional imaging, mainly computed tomography, is an indispensable tool in recognising ectopic periaortic air and to identify the associated findings and eventually make an accurate diagnosis. We present a pictorial review of various causes of the periaortic air in native and postoperative aorta, the salient features and management of the described conditions.


Asunto(s)
Aire , Aorta/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Complicaciones Posoperatorias/diagnóstico por imagen , Aneurisma Infectado/diagnóstico por imagen , Aneurisma Infectado/etiología , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/etiología , Aortitis/diagnóstico por imagen , Aortitis/etiología , Enfermedades Bronquiales/diagnóstico por imagen , Enfermedades Bronquiales/etiología , Angiografía por Tomografía Computarizada/métodos , Fístula/diagnóstico por imagen , Fístula/etiología , Supervivencia de Injerto , Humanos , Fístula Intestinal/diagnóstico por imagen , Fístula Intestinal/etiología
9.
Vasc Endovascular Surg ; 56(6): 553-560, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35469497

RESUMEN

PURPOSE: To evaluate the remodeling of visceral arteries post-endovascular repair (TEVAR) of type B aortic dissection and to investigate interval change in renal volume and estimated glomerular filtration rate (eGFR) vis-a-vis baseline visceral artery morphology. MATERIALS AND METHODS: All patients of type B aortic dissection who underwent TEVAR with a baseline and follow-up CT during the study period were included. Baseline morphology of visceral arteries (celiac, superior, and inferior mesenteric artery and bilateral renal artery) were classified into 7 patterns depending upon the origin of the artery (from true/false lumen) and the extension of dissection flap, while occluded vessels were categorized as pattern 8. RESULTS: One hundred and thirty-two branches were analyzed in 25 patients (23 males; mean age: 50.1 years) with a mean follow-up of 386 days. 51 visceral branches were arising from the true lumen without any stenosis. Of the remaining 81 branches, 48 showed favorable remodeling (P = .0001). The highest incidence of favorable remodeling was observed in arteries arising from the true lumen (pattern 2,3: 44/48; 91.6%) whereas only one thrombosed and artery arising from the false lumen each (pattern 5 and 8) showed favorable remodeling. Kidneys perfused by false lumen or occluded renal artery suffered statistically significant volume loss compared to kidneys perfused by true or both lumens (-16.5% vs .2%; P = .01); however, the change in eGFR failed to reach statistical significance. CONCLUSION: Visceral arteries arising from the true lumen are more likely to undergo favorable remodeling. The kidneys supplied by false lumen or by occluded renal artery suffer significantly more volume loss after TEVAR.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Humanos , Riñón/fisiología , Masculino , Persona de Mediana Edad , Arteria Renal/diagnóstico por imagen , Arteria Renal/cirugía , Estudios Retrospectivos , Stents , Resultado del Tratamiento
10.
Indian J Thorac Cardiovasc Surg ; 38(4): 375-381, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35756554

RESUMEN

Objectives: To examine the association between aortic coverage and occurrence of spinal cord ischemia (SCI) after thoracic endovascular aortic repair (TEVAR) for type B aortic dissection. Methods: Thirty-eight consecutive patients (mean age 52 years; 35 men) who underwent TEVAR for type B aortic dissection at our centre were included. Patients were stratified into two groups based on stent graft length (SGL): group I (≤ 200 mm; n = 19) and group II (> 200 mm; n = 19). All the procedures were performed under strict blood pressure monitoring. Preoperative cerebrospinal fluid (CSF) drain was instituted in two patients. Results: Mean SGLs were 200 mm in group I and 277 ± 27 mm in group II. The number of segmental arteries covered was significantly different between the two groups (p < 0.001). There was no significant difference in vertebral artery dominance between groups I and II (p = 0.99). One patient in group II, who also had bilateral internal iliac artery occlusion, developed postprocedural neurological deficit referrable to SCI, which resolved completely after institution of CSF drainage. However, the incidence of SCI was not significantly different between group I and group II (p = 0.5). Conclusion: Based on our experience, we recommend longer aortic coverage (beyond 200 mm) in type B aortic dissection (TBAD) for better aortic remodelling, provided that the mean arterial pressure of > 90 mm Hg is maintained perioperatively to avoid SCI.

11.
Indian J Radiol Imaging ; 32(3): 324-331, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36177280

RESUMEN

Background Migration of the stent-graft post-thoracic endovascular aortic repair (TEVAR) is not uncommon; however, it is sparsely reported. The objective of this study was to assess the incidence, risk factors, and complications of stent-graft migration post-TEVAR. Materials and Methods Thirty-one patients who underwent TEVAR were retrospectively analyzed. The demographic, anatomical, and procedure-related factors were assessed. The measurements were done along the greater curvature of aorta around two fixed anatomic landmarks, that is, left common carotid artery or neoinnominate artery (hybrid repair) proximally and celiac artery distally. Aortic elongation and migration at proximal, distal, as well as at overlapping zone were measured. More than 10 mm of migration was considered significant. Results Significant migration was observed in six (19%) patients. No significant migration was observed in the overlapping zone. The proximal landing zone 3 (odds ratio [OR] 12.78, p 0.01) was a significant risk factor, whereas landing zone 2 was a protective factor against the migration (OR 0.08, p 0.02). The odds for migration were more in segments I/3 and II/3 compared with I/2 and II/2, respectively, as per Modified Arch Landing Areas Nomenclature. A single complication was seen in the migration group which was treated by an overlapping stent graft. Conclusion The stent-graft migration after TEVAR is not uncommon. Type 3 proximal landing zone was a significant risk factor for migration with an increased risk toward I/3 and II/3. Proximal landing zone 2 as well as adequate overlapping distance in multiple stent grafts can prevent migration. Ethical Approval No IECPG-227/24.06.2020.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA