Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 83
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38782173

RESUMEN

BACKGROUND & AIMS: Conventional endoscopic mucosal resection (C-EMR) is established as the primary treatment modality for superficial nonampullary duodenal epithelial tumors (SNADETs), but recently underwater endoscopic mucosal resection (U-EMR) has emerged as a potential alternative. The majority of previous studies focused on Asian populations and small lesions (≤20 mm). We aimed to compare the efficacy and outcomes of U-EMR vs C-EMR for SNADETs in a Western setting. METHODS: This was a retrospective multinational study from 10 European centers that performed both C-EMR and U-EMR between January 2013 and July 2023. The main outcomes were the technical success, procedure-related adverse events (AEs), and the residual/recurrent adenoma (RRA) rate, evaluated on a per-lesion basis. We assessed the association between the type of endoscopic mucosal resection and the occurrence of AEs or RRAs using mixed-effects logistic regression models (propensity scores). Sensitivity analyses were performed for lesions ≤20 mm or >20 mm. RESULTS: A total of 290 SNADETs submitted to endoscopic resection during the study period met the inclusion criteria and were analyzed (C-EMR: n = 201, 69.3%; U-EMR: n = 89, 30.7%). The overall technical success rate was 95.5% and comparable between groups. In logistic regression models, compared with U-EMR, C-EMR was associated with a significantly higher frequency of overall delayed AEs (odds ratio [OR], 4.95; 95% CI, 2.87-8.53), postprocedural bleeding (OR, 7.92; 95% CI, 3.95-15.89), and RRAs (OR, 3.66; 95% CI, 2.49-5.37). Sensitivity analyses confirmed these results when solely considering either small (≤20 mm) or large (>20 mm) lesions. CONCLUSIONS: Compared with C-EMR, U-EMR was associated with a lower rate of overall AEs and RRAs, regardless of lesion size. Our results confirm the possible role of U-EMR as an effective and safe technique in the management of SNADETs.

2.
Gastrointest Endosc ; 2024 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-38272273

RESUMEN

BACKGROUND AND AIMS: Small bowel (SB) capsule endoscopy (CE) is a first line procedure for exploring the SB. Endoscopic GastroIntestinal PlacemenT (EGIPT) of SB CE is sometimes necessary. While the experience of EGIPT is large in pediatric populations, we aimed to describe the safety, efficacy and outcomes of EGIPT of SB CE in adult patients. METHODS: The international CApsule endoscopy REsearch (iCARE) group set up a retrospective multicenter study. Patients over 18 year-old who underwent EGIPT of SB CE before May 2022 were included. Data were collected from medical records and capsule recordings. The primary endpoint was the technical success rate of the EGIPT procedures. RESULTS: 630 patients were included (mean age 62.5 years old, 55.9% female) from 39,565 patients (1.6%) issued from 29 centers. EGIPT technical success was achieved in 610 procedures (96.8%). Anesthesia (moderate/deep sedation or general anesthesia) and centers with intermediate or high procedure loads were independent factors of technical success. Severe adverse events occurred in three (0.5%) patients. When technically successful, EGIPT was associated with a high SB CE completion rate (84.4%) and with a substantial diagnostic yield (61.1%). Completion rate was significantly higher when the capsule was delivered in the SB compared to when delivered in the stomach. CONCLUSION: EGIPT of SB CE is highly feasible, safe and comes with high completion rate and diagnostic yield. When indicated, it should rather be performed under anesthesia and the capsule should be delivered in the duodenum rather than in the stomach, for better SB examination outcomes.

3.
Endoscopy ; 56(3): 174-181, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37949103

RESUMEN

BACKGROUND: Device-assisted enteroscopy (DAE) has become a well-established diagnostic and therapeutic tool for the management of small-bowel pathology. We aimed to evaluate the performance measures for DAE across the UK against the quality benchmarks proposed by the European Society of Gastrointestinal Endoscopy (ESGE). METHODS: We retrospectively collected data on patient demographics and DAE performance measures from electronic endoscopy records of consecutive patients who underwent DAE for diagnostic and therapeutic purposes across 12 enteroscopy centers in the UK between January 2017 and December 2022. RESULTS: A total of 2005 DAE procedures were performed in 1663 patients (median age 60 years; 53% men). Almost all procedures (98.1%) were performed for appropriate indications. Double-balloon enteroscopy was used for most procedures (82.0%), followed by single-balloon enteroscopy (17.2%) and spiral enteroscopy (0.7%). The estimated depth of insertion was documented in 73.4% of procedures. The overall diagnostic yield was 70.0%. Therapeutic interventions were performed in 42.6% of procedures, with a success rate of 96.6%. Overall, 78.0% of detected lesions were marked with a tattoo. Patient comfort was significantly better with the use of deep sedation compared with conscious sedation (99.7% vs. 68.5%; P<0.001). Major adverse events occurred in only 0.6% of procedures. CONCLUSIONS: Performance measures for DAE in the UK meet the ESGE quality benchmarks, with high diagnostic and therapeutic yields, and a low incidence of major adverse events. However, there is room for improvement in optimizing sedation practices, standardizing the depth of insertion documentation, and adopting marking techniques to aid in the follow-up of detected lesions.


Asunto(s)
Enfermedades Intestinales , Masculino , Humanos , Persona de Mediana Edad , Femenino , Enfermedades Intestinales/diagnóstico , Enfermedades Intestinales/terapia , Estudios Retrospectivos , Mejoramiento de la Calidad , Endoscopía Gastrointestinal/métodos , Intestino Delgado/diagnóstico por imagen , Intestino Delgado/patología , Enteroscopía de Doble Balón/métodos
4.
Scand J Gastroenterol ; : 1-7, 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38821110

RESUMEN

BACKGROUND: Gastroesophageal reflux disease (GERD) symptoms frequently recur after cessation of acid blockers. The presence of a hiatal hernia may worsen GERD symptoms and increase the risk of esophageal malignancy. The aim of this study is to clarify the timing and predictors for recurrence of GERD symptoms after cessation of vonoprazan (VPZ) therapy. METHODS: A retrospective observational study involved 86 patients who underwent cessation of VPZ therapy for symptomatic GERD. Collated data from medical record review included the endoscopic findings and Izumo scale score. RESULTS: The mean duration of continuous VPZ therapy before cessation was 7.9 months. GERD symptoms requiring the resumption of VPZ therapy recurred in 66 of 86 patients (77%). Kaplan-Meier analysis showed that overall recurrence-free rates at 6 months, one and two years after VPZ cessation were 44%, 32% and 23%, respectively. Alcohol use, the presence of a hiatal hernia and long-term therapy for more than six months were identified as significant positive predictors for symptomatic recurrence. Notably, hiatal hernia had the highest hazard ratio in both univariate and multivariate analyses. The recurrence-free rate in patients with a hiatal hernia was much lower at 6 months than in patients without a hiatal hernia (15% and 51%, respectively p = 0.002). After the symptomatic recurrence, GERD symptoms improved significantly after one-month VPZ therapy. CONCLUSION: The rate of symptomatic recurrence after VPZ cessation in patients with GERD is considerable. Cessation of acid suppression therapy should be cautious in patients with both a hiatal hernia and GERD.

5.
Endoscopy ; 55(1): 58-95, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36423618

RESUMEN

MR1: ESGE recommends small-bowel capsule endoscopy as the first-line examination, before consideration of other endoscopic and radiological diagnostic tests for suspected small-bowel bleeding, given the excellent safety profile of capsule endoscopy, its patient tolerability, and its potential to visualize the entire small-bowel mucosa.Strong recommendation, moderate quality evidence. MR2: ESGE recommends small-bowel capsule endoscopy in patients with overt suspected small-bowel bleeding as soon as possible after the bleeding episode, ideally within 48 hours, to maximize the diagnostic and subsequent therapeutic yield.Strong recommendation, high quality evidence. MR3: ESGE does not recommend routine second-look endoscopy prior to small-bowel capsule endoscopy in patients with suspected small-bowel bleeding or iron-deficiency anemia.Strong recommendation, low quality evidence. MR4: ESGE recommends conservative management in those patients with suspected small-bowel bleeding and high quality negative small-bowel capsule endoscopy.Strong recommendation, moderate quality evidence. MR5: ESGE recommends device-assisted enteroscopy to confirm and possibly treat lesions identified by small-bowel capsule endoscopy.Strong recommendation, high quality evidence. MR6: ESGE recommends the performance of small-bowel capsule endoscopy as a first-line examination in patients with iron-deficiency anemia when small bowel evaluation is indicated.Strong recommendation, high quality evidence. MR7: ESGE recommends small-bowel capsule endoscopy in patients with suspected Crohn's disease and negative ileocolonoscopy findings as the initial diagnostic modality for investigating the small bowel, in the absence of obstructive symptoms or known bowel stenosis.Strong recommendation, high quality evidence. MR8: ESGE recommends, in patients with unremarkable or nondiagnostic findings from dedicated small-bowel cross-sectional imaging, small-bowel capsule endoscopy as a subsequent investigation if deemed likely to influence patient management.Strong recommendation, low quality evidence. MR9: ESGE recommends, in patients with established Crohn's disease, the use of a patency capsule before small-bowel capsule endoscopy to decrease the capsule retention rate.Strong recommendation, moderate quality evidence. MR10: ESGE recommends device-assisted enteroscopy (DAE) as an alternative to surgery for foreign bodies retained in the small bowel requiring retrieval in patients without acute intestinal obstruction.Strong recommendation, moderate quality evidence. MR11: ESGE recommends DAE-endoscopic retrograde cholangiopancreatography (DAE-ERCP) as a first-line endoscopic approach to treat pancreaticobiliary diseases in patients with surgically altered anatomy (except for Billroth II patients).Strong recommendation, moderate quality evidence.


Asunto(s)
Anemia Ferropénica , Endoscopía Capsular , Enfermedad de Crohn , Enfermedades Intestinales , Humanos , Anemia Ferropénica/diagnóstico , Anemia Ferropénica/etiología , Anemia Ferropénica/terapia , Endoscopía Gastrointestinal/métodos , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiología , Hemorragia Gastrointestinal/terapia , Enfermedades Intestinales/diagnóstico , Enfermedades Intestinales/terapia
6.
Endoscopy ; 54(9): 904-915, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35913069

RESUMEN

The European Society of Gastrointestinal Endoscopy (ESGE) presents a short list of performance measures for colonoscopy in inflammatory bowel disease (IBD) patients. Current performance measures for colonoscopy mainly focus on detecting (pre)malignant lesions. However, these performance measures are not relevant for all colonoscopy indications in IBD patients. Therefore, our aim was to provide endoscopy services across Europe and other interested countries with a tool for quality monitoring and improvement in IBD colonoscopy. Eight key performance measures and one minor performance measure were recommended for measurement and evaluation in daily endoscopy practice.


Asunto(s)
Enfermedades Inflamatorias del Intestino , Mejoramiento de la Calidad , Colonoscopía , Endoscopía Gastrointestinal , Europa (Continente) , Humanos , Enfermedades Inflamatorias del Intestino/diagnóstico por imagen
7.
Gastrointest Endosc ; 93(6): 1325-1332, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33221321

RESUMEN

BACKGROUND AND AIMS: Buried bumper syndrome (BBS) is a rare adverse event of percutaneous endoscopic gastrostomy (PEG) placement in which the internal bumper migrates through the stomal tract to become embedded within the gastric wall. Excessive tension between the internal and external bumpers, causing ischemic necrosis of the gastric wall, is believed to be the main etiologic factor. Several techniques for endoscopic management of BBS have been described using off-label devices. The Flamingo set is a novel, sphincterotome-like device specifically designed for BBS management. We aimed to evaluate the effectiveness of the Flamingo device in a large, homogeneous cohort of patients with BBS. METHODS: A guidewire was inserted through the external access of the PEG tube into the gastric lumen. The Flamingo device was then introduced into the stomach over the guidewire. This dedicated tool can be flexed by 180 degrees, exposing a sphincterotome-like cutting wire, which is used to incise the overgrown tissue until the PEG bumper is exposed. A retrospective, international, multicenter cohort study was conducted on 54 patients between December 2016 and February 2019. RESULTS: The buried bumper was successfully removed in 53 of 55 procedures (96.4%). The median time for the endoscopic removal of the buried bumper was 22 minutes (range, 5-60). Periprocedural endoscopic adverse events occurred in 7 procedures (12.7%) and were successfully managed endoscopically. A median follow-up of 150 days (range, 33-593) was performed in 29 patients (52.7%), during which no significant adverse events occurred. CONCLUSIONS: Through our experience, we found this dedicated novel device to be safe, quick, and effective for minimally invasive, endoscopic management of BBS.


Asunto(s)
Nutrición Enteral , Gastrostomía , Estudios de Cohortes , Remoción de Dispositivos , Humanos , Estudios Retrospectivos
8.
Endoscopy ; 53(2): 178-195, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33348410

RESUMEN

ESGE recommends the "pull" technique as the standard method for percutaneous endoscopic gastrostomy (PEG) placement.Strong recommendation, low quality evidence.ESGE recommends the direct percutaneous introducer ("push") technique for PEG placement in cases where the "pull" method is contraindicated, for example in severe esophageal stenosis or in patients with head and neck cancer (HNC) or esophageal cancer.Strong recommendation, low quality evidence.ESGE recommends the intravenous administration of a prophylactic single dose of a beta-lactam antibiotic (or appropriate alternative antibiotic, in the case of allergy) to decrease the risk of post-procedural wound infection.Strong recommendation, moderate quality evidence.ESGE recommends that inadvertent insertion of a nasogastric tube (NGT) into the respiratory tract should be considered a serious but avoidable adverse event (AE).Strong recommendation, low quality evidence.ESGE recommends that each institution should have a dedicated protocol to confirm correct positioning of NGTs placed "blindly" at the patient's bedside; this should include: radiography, pH testing of the aspirate, and end-tidal carbon dioxide monitoring, but not auscultation alone.Strong recommendation, low quality evidence.ESGE recommends confirmation of correct NGT placement by radiography in high-risk patients (intensive care unit [ICU] patients or those with altered consciousness or absent gag/cough reflex).Strong recommendation, low quality evidence.ESGE recommends that EN may be started within 3 - 4 hours after uncomplicated placement of a PEG or PEG-J.Strong recommendation, high quality evidence.ESGE recommends that daily tube mobilization (pushing inward) along with a loose position of the external PEG bumper (1 - 2 cm from the abdominal wall) could mitigate the risk of development of buried bumper syndrome.Strong recommendation, low quality evidence.


Asunto(s)
Nutrición Enteral , Gastrostomía , Adulto , Endoscopía Gastrointestinal , Gastrostomía/efectos adversos , Humanos
9.
Endoscopy ; 53(1): 81-92, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33260229

RESUMEN

ESGE recommends considering the following indications for enteral tube insertion: (i) clinical conditions that make oral intake impossible (neurological conditions, obstructive causes); (ii) acute and/or chronic diseases that result in a catabolic state where oral intake becomes insufficient; and (iii) chronic small-bowel obstruction requiring a decompression gastrostomy.Strong recommendation, low quality evidence.ESGE recommends the use of temporary feeding tubes placed through a natural orifice (either nostril) in patients expected to require enteral nutrition (EN) for less than 4 weeks. If it is anticipated that EN will be required for more than 4 weeks, percutaneous access should be considered, depending on the clinical setting.Strong recommendation, low quality evidence.ESGE recommends the gastric route as the primary option in patients in need of EN support. Only in patients with altered/unfavorable gastric anatomy (e. g. after previous surgery), impaired gastric emptying, intolerance to gastric feeding, or with a high risk of aspiration, should the jejunal route be chosen.Strong recommendation, moderate quality evidence.ESGE suggests that recent gastrointestinal (GI) bleeding due to peptic ulcer disease with risk of rebleeding should be considered to be a relative contraindication to percutaneous enteral access procedures, as should hemodynamic or respiratory instability.Weak recommendation, low quality evidence.ESGE suggests that the presence of ascites and ventriculoperitoneal shunts should be considered to be additional risk factors for infection and, therefore, further preventive precautions must be taken in these cases.Weak recommendation, low quality evidence.ESGE recommends that percutaneous tube placement (percutaneous endoscopic gastrostomy [PEG], percutaneous endoscopic gastrostomy with jejunal extension [PEG-J], or direct percutaneous endoscopic jejunostomy [D-PEJ]) should be considered to be a procedure with high hemorrhagic risk, and that in order to reduce this risk, specific guidelines for antiplatelet or anticoagulant use should be followed strictly.Strong recommendation, low quality evidence.ESGE recommends refraining from PEG placement in patients with advanced dementia.Strong recommendation, low quality evidence.ESGE recommends refraining from PEG placement in patients with a life expectancy shorter than 30 days.Strong recommendation, low quality evidence*.


Asunto(s)
Endoscopía Gastrointestinal , Hemorragia Gastrointestinal , Adulto , Gastrostomía/efectos adversos , Humanos , Intestino Delgado
10.
Endoscopy ; 53(1): 36-43, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32459000

RESUMEN

BACKGROUND: Upper gastrointestinal bleeding (UGIB) is a leading cause of morbidity and is associated with a 2 % - 17 % mortality rate in the UK and USA. Bleeding peptic ulcers account for 50 % of UGIB cases. Endoscopic intervention in a timely manner can improve outcomes. Hemostatic spray is an endoscopic hemostatic powder for GI bleeding. This multicenter registry was created to collect data prospectively on the immediate endoscopic hemostasis of GI bleeding in patients with peptic ulcer disease when hemostatic spray is applied as endoscopic monotherapy, dual therapy, or rescue therapy. METHODS: Data were collected prospectively (January 2016 - March 2019) from 14 centers in the UK, France, Germany, and the USA. The application of hemostatic spray was decided upon at the endoscopist's discretion. RESULTS: 202 patients with UGIB secondary to peptic ulcers were recruited. Immediate hemostasis was achieved in 178/202 patients (88 %), 26/154 (17 %) experienced rebleeding, 21/175 (12 %) died within 7 days, and 38/175 (22 %) died within 30 days (all-cause mortality). Combination therapy of hemostatic spray with other endoscopic modalities had an associated lower 30-day mortality (16 %, P < 0.05) compared with monotherapy or rescue therapy. There were high immediate hemostasis rates across all peptic ulcer disease Forrest classifications. CONCLUSIONS: This is the largest case series of outcomes of peptic ulcer bleeding treated with hemostatic spray, with high immediate hemostasis rates for bleeding peptic ulcers.


Asunto(s)
Hemostasis Endoscópica , Hemostáticos , Úlcera Péptica , Francia , Alemania , Humanos , Minerales , Recurrencia Local de Neoplasia , Úlcera Péptica Hemorrágica/terapia , Polvos , Recurrencia , Sistema de Registros , Resultado del Tratamiento
11.
J Gastroenterol Hepatol ; 36(11): 3027-3032, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34132412

RESUMEN

BACKGROUND AND AIM: Upper gastrointestinal tumors account for 5% of upper gastrointestinal bleeds. These patients are challenging to treat due to the diffuse nature of the neoplastic bleeding lesions, high rebleeding rates, and significant transfusion requirements. TC-325 (Cook Medical, North Carolina, USA) is a hemostatic powder for gastrointestinal bleeding. The aim of this study was to examine the outcomes of upper gastrointestinal bleeds secondary to tumors treated with Hemospray therapy. METHODS: Data were prospectively collected on the use of Hemospray from 17 centers. Hemospray was used during emergency endoscopy for upper gastrointestinal bleeds secondary to tumors at the discretion of the endoscopist as a monotherapy, dual therapy with standard hemostatic techniques, or rescue therapy. RESULTS: One hundred and five patients with upper gastrointestinal bleeds secondary to tumors were recruited. The median Blatchford score at baseline was 10 (interquartile range [IQR], 7-12). The median Rockall score was 8 (IQR, 7-9). Immediate hemostasis was achieved in 102/105 (97%) patients, 15% of patients had a 30-day rebleed, 20% of patients died within 30 days (all-cause mortality). There was a significant improvement in transfusion requirements following treatment (P < 0.001) when comparing the number of units transfused 3 weeks before and after treatment. The mean reduction was one unit per patient. CONCLUSIONS: Hemospray achieved high rates of immediate hemostasis, with comparable rebleed rates following treatment of tumor-related upper gastrointestinal bleeds. Hemospray helped in improving transfusion requirements in these patients. This allows for patient stabilization and bridges towards definitive surgery or radiotherapy to treat the underlying tumor.


Asunto(s)
Hemorragia Gastrointestinal , Neoplasias Gastrointestinales , Hemostasis Endoscópica , Hemostáticos , Minerales , Anciano , Anciano de 80 o más Años , Neoplasias Duodenales/complicaciones , Neoplasias Esofágicas/complicaciones , Femenino , Hemorragia Gastrointestinal/etiología , Hemorragia Gastrointestinal/terapia , Neoplasias Gastrointestinales/complicaciones , Hemostáticos/administración & dosificación , Hemostáticos/uso terapéutico , Humanos , Masculino , Persona de Mediana Edad , Minerales/administración & dosificación , Minerales/uso terapéutico , Polvos , Recurrencia , Sistema de Registros , Neoplasias Gástricas/complicaciones , Resultado del Tratamiento
12.
Endoscopy ; 52(8): 669-686, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32557476

RESUMEN

The European Society of Gastrointestinal Endoscopy (ESGE) has recognized the need to formalize training in small-bowel endoscopy across European centers. The following criteria and framework for training in small-bowel capsule endoscopy (SBCE) and device-assisted enteroscopy (DAE), which aim to provide uniform and high quality training to ensure that small-bowel endoscopists are competent to operate independently, are based on the current literature and experience of experts in the field. Three main areas are covered: skills required prior to commencing training in small-bowel endoscopy; structured training for trainees to become independent endoscopists; and ways of ensuring competence is achieved. 1 : Centers providing training in SBCE should perform a minimum of 75 - 100 SBCEs/year. 2 : Experience in bidirectional endoscopies is desirable for structured training in SBCE. 3 : SBCE courses should consist of at least 50 % hands-on training and cover information on technology, indications and contraindications for SBCE, pathologies that can be encountered on SBCE, and standard terminology that should be used during reporting of SBCE. An SBCE course should be completed prior to achieving competence in SBCE reporting. 4 : Competence in SBCE can be assessed by considering a minimum of 30 SBCEs. Direct Observation of Procedural Skills, short SBCE videos, and multiple-choice questions can be useful to assess improvement in the skills of trainees. 5 : Centers offering training in DAE should aim to carry out at least 75 DAEs/year, should have direct links with an SBCE service, and should allow regular discussion of cases at a radiology small-bowel MDT. Training centers with lower numbers are encouraged to offer training by "buddying-up" with other centers, or using mentoring systems. 6 : DAE trainees must be independent in bidirectional endoscopies and have experience in level 1 polypectomy prior to commencement of training. They should also be competent in reviewing SBCEs. 7 : Training in DAE should be structured with a minimum of 75 procedures, including 35 retrograde DAEs, with therapeutic procedures undertaken in at least 50 % of the DAEs performed. Training should cover the indications, contraindications, complications including prevention, and technicalities of the DAE procedure; formal evaluation should follow. DAE trainees must acquire skills to independently manage and advise on small-bowel pathology following DAE procedures. 8 : It is highly recommended that international societies develop online modules and courses on DAE, which are currently lacking across Europe.


Asunto(s)
Endoscopía Capsular , Competencia Clínica , Curriculum , Evaluación Educacional , Europa (Continente) , Humanos
13.
Dig Endosc ; 32(1): 96-105, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31365756

RESUMEN

BACKGROUND AND AIM: Acute gastrointestinal bleeding carries poor outcomes unless prompt endoscopic hemostasis is achieved. Mortality in these patients remains significant. Hemospray is a novel intervention that creates a mechanical barrier over bleeding sites. We report the largest dataset of patient outcomes after treatment with Hemospray from an international multicenter registry. PATIENTS AND METHODS: Prospective data (Jan 2016-May 2018) from 12 centers across Europe were collected. Immediate hemostasis was defined as endoscopic cessation of bleeding within 5 min after application of Hemospray. Rebleeding was defined as subsequent drop in hemoglobin, hematemesis, persistent melena with hemodynamic compromise post-therapy. RESULTS: Three hundred and fourteen cases were recruited worldwide (231 males, 83 females). Median pretreatment Blatchford score was 11 (IQR: 8-14) and median complete Rockall score (RS) was 7 (IQR: 6-8) for all patients. Peptic ulcer disease (PUD) was the most common pathology (167/314 = 53%) and Forrest Ib the most common bleed type in PUD (100/167 = 60%). 281 patients (89.5%) achieved immediate hemostasis after successful endoscopic therapy with Hemospray. Rebleeding occurred in 29 (10.3%) of the 281 patients who achieved immediate hemostasis. Seven-day and 30-day all-cause mortality were 11.5% (36/314) and 20.1% (63/314), respectively (lower than the predicted rates as per the RS). Similar hemostasis rates were noted in the Hemospray monotherapy (92.4%), combination therapy (88.7%) and rescue therapy (85.5%) groups. CONCLUSIONS: These data show high rates of immediate hemostasis overall and in all subgroups. Rebleeding and mortality rates were in keeping/lower than predicted rates.


Asunto(s)
Hemorragia Gastrointestinal/terapia , Hemostasis Endoscópica/métodos , Hemostáticos/administración & dosificación , Minerales/administración & dosificación , Enfermedad Aguda , Administración Tópica , Anciano , Anciano de 80 o más Años , Femenino , Hemorragia Gastrointestinal/etiología , Gastroscopía , Humanos , Internacionalidad , Masculino , Persona de Mediana Edad , Úlcera Péptica Hemorrágica/etiología , Úlcera Péptica Hemorrágica/terapia , Estudios Prospectivos , Recurrencia , Sistema de Registros , Medición de Riesgo , Resultado del Tratamiento
15.
Gastrointest Endosc ; 90(2): 302-306, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-30980796

RESUMEN

BACKGROUND AND AIMS: Small-bowel varices (SBVs) are an uncommon consequence of portal hypertension. Radiologic intervention is usually considered for first-line management. When radiologic intervention is not possible, management options become very limited. The aim of this study was to evaluate the usefulness of double-balloon enteroscopy (DBE)-facilitated cyanoacrylate-injection endotherapy of SBVs. METHODS: This was a retrospective review of DBE-facilitated cyanoacrylate-injection endotherapy of SBVs (December 2015 to October 2016). RESULTS: Ten DBEs were performed in 6 patients (4 women; median age, 68.5 years). No radiologic or surgical options were deemed feasible. Thirteen nests of SBVs were identified and injected with cyanoacrylate glue without hemorrhagic or embolic adverse events. At the 30-day follow-up after therapy, only 1 patient had experienced a mild recurrence of mid-gut bleeding; this was managed conservatively. One patient presented with acute GI bleeding 7 months later, and a repeat DBE with cyanoacrylate-injection endotherapy was successfully performed. One patient succumbed to his underlying advanced cholangiocarcinoma after 2 months. The remaining patients had a median follow-up of 12 months without any recurrent GI bleeding. CONCLUSIONS: DBE-facilitated cyanoacrylate-injection endotherapy of SBVs appears to be a safe and effective option when other first-line options are not feasible.


Asunto(s)
Cianoacrilatos/administración & dosificación , Enteroscopía de Doble Balón , Intestino Delgado/irrigación sanguínea , Várices/tratamiento farmacológico , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Inyecciones/métodos , Cooperación Internacional , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Centros de Atención Terciaria
20.
Endoscopy ; 51(6): 574-598, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-31075800

RESUMEN

The European Society of Gastrointestinal Endoscopy (ESGE) together with the United European Gastroenterology (UEG) recently developed a short list of performance measures for small-bowel endoscopy (i. e. small-bowel capsule endoscopy and device-assisted enteroscopy) with the final goal of providing endoscopy services across Europe with a tool for quality improvement. Six key performance measures for both small-bowel capsule endoscopy and for device-assisted enteroscopy were selected for inclusion, with the intention being that practice at both a service and endoscopist level should be evaluated against them. Other performance measures were considered to be less relevant, based on an assessment of their overall importance, scientific acceptability, and feasibility. Unlike lower and upper gastrointestinal endoscopy, where performance measures had already been identified, this is the first time that small-bowel endoscopy quality measures have been proposed.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA