Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
AJR Am J Roentgenol ; 218(4): 570-581, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34851713

RESUMEN

Despite important innovations in the treatment of pancreatic ductal adenocarcinoma (PDAC), PDAC remains a disease with poor prognosis and high mortality. A key area for potential improvement in the management of PDAC, aside from earlier detection in patients with treatable disease, is the improved ability of imaging techniques to differentiate treatment response after neoadjuvant therapy (NAT) from worsening disease. It is well established that current imaging techniques cannot reliably make this distinction. This narrative review provides an update on the imaging assessment of pancreatic cancer resectability after NAT. Current definitions of borderline resectable PDAC, as well as implications for determining likely patient benefit from NAT, are described. Challenges associated with PDAC pathologic evaluation and surgical decision making that are of relevance to radiologists are discussed. Also explored are the specific limitations of imaging in differentiating the response after NAT from stable or worsening disease, including issues relating to protocol optimization, tumor size assessment, vascular assessment, and liver metastasis detection. The roles of MRI as well as PET and/or hybrid imaging are considered. Finally, a short PDAC reporting template is provided for use after NAT. The highlighted methods seek to improve radiologists' assessment of PDAC treatment response after NAT.


Asunto(s)
Adenocarcinoma , Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Adenocarcinoma/patología , Carcinoma Ductal Pancreático/diagnóstico por imagen , Carcinoma Ductal Pancreático/tratamiento farmacológico , Carcinoma Ductal Pancreático/cirugía , Humanos , Terapia Neoadyuvante , Pancreatectomía , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/tratamiento farmacológico , Neoplasias Pancreáticas/cirugía , Neoplasias Pancreáticas
2.
AJR Am J Roentgenol ; 216(2): 479-485, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33295817

RESUMEN

OBJECTIVE. Using the American College of Radiology (ACR) Thyroid Imaging Reporting and Data System (TI-RADS), this study sought to determine whether decreasing the point assignment for punctate echogenic foci in mixed solid and cystic nodules would reduce the number of benign mixed solid and cystic nodules that were biopsied and would not substantially increase the number of missed mixed carcinomas MATERIALS AND METHODS. A multiinstitutional database of 3422 pathologically proven thyroid nodules was evaluated to identify all mixed solid and cystic nodules with punctate echogenic foci. We determined the numbers of mixed benign and malignant nodules that would receive ACR TI-RADS recommendations of fine-needle aspiration, follow-up, and no further evaluation if the points assigned to punctate echogenic foci were changed from 3 points to 1 or 2 points. RESULTS. A total of 287 mixed nodules were adequately characterized for evaluation. When the number of points assigned to punctate echogenic foci was changed from 3 points to 1 point, the point categories changed for 198 mixed nodules. Seven carcinomas would not undergo biopsy, but six of those seven would receive follow-up, and 44 benign nodules would not undergo biopsy. When 2 points were assigned to punctate echogenic foci, the point categories changed for 66 mixed nodules. Three carcinomas would not undergo biopsy, but all three of these would receive follow-up, and eight benign nodules would not undergo biopsy. CONCLUSION. Consideration should be given to decreasing the number of points assigned to punctate echogenic foci in mixed solid and cystic thyroid nodules, given the substantial decrease in the number of benign nodules requiring biopsy and the recommendation of follow-up for any carcinoma 1 cm or larger that did not undergo biopsy.


Asunto(s)
Carcinoma/diagnóstico , Nódulo Tiroideo/diagnóstico por imagen , Nódulo Tiroideo/patología , Ultrasonografía , Biopsia con Aguja Fina , Humanos , Sistemas de Información Radiológica , Reproducibilidad de los Resultados , Estudios Retrospectivos
3.
AJR Am J Roentgenol ; 217(3): 718-719, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33470836

RESUMEN

Emerging data suggest that the location of thyroid nodules influences malignancy risk. The purpose of this study was to explore the impact of including location in American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) scoring. Four of five revised scoring algorithms that added 1 or 2 points to higher-risk locations were associated with lowered accuracy due to lower specificity. However, an algorithm that added 1 point to isthmic nodules did not differ significantly from ACR TI-RADS in accuracy; one additional isthmic cancer was diagnosed for each 10.3 additional benign nodules recommended for biopsy.


Asunto(s)
Sistemas de Información Radiológica/estadística & datos numéricos , Neoplasias de la Tiroides/diagnóstico por imagen , Neoplasias de la Tiroides/patología , Nódulo Tiroideo/diagnóstico por imagen , Nódulo Tiroideo/patología , Ultrasonografía/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Biopsia con Aguja Fina/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radiología , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sociedades Médicas , Glándula Tiroides/diagnóstico por imagen , Glándula Tiroides/patología , Estados Unidos , Adulto Joven
4.
AJR Am J Roentgenol ; 216(2): 471-478, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32603228

RESUMEN

OBJECTIVE. Compared with other guidelines, the American College of Radiology (ACR) Thyroid Imaging Reporting and Data System (TI-RADS) has decreased the number of nodules for which fine-needle aspiration is recommended. The purpose of this study was to evaluate the characteristics of malignant nodules that would not be biopsied when the ACR TI-RADS recommendations are followed. MATERIALS AND METHODS. We retrospectively reviewed a total of 3422 thyroid nodules for which a definitive cytologic diagnosis, a definitive histologic diagnosis, or both diagnoses as well as diagnostic ultrasound (US) examinations were available. All nodules were categorized using the ACR TI-RADS, and they were divided into three groups according to the recommendation received: fine-needle aspiration (group 1), follow-up US examination (group 2), or no further evaluation (group 3). RESULTS. Of the 3422 nodules, 352 were malignant. Of these, 240 nodules were assigned to group 1, whereas 72 were assigned to group 2 and 40 were included in group 3. Sixteen of the 40 malignant nodules in group 3 were 1 cm or larger, and, on the basis of analysis of the sonographic features described in the ACR TI-RADS, these nodules were classified as having one of five ACR TI-RADS risk levels (TR1-TR5), with one nodule classified as a TR1 nodule, eight as TR2 nodules, and seven as TR3 nodules. If the current recommendation of no follow-up for TR2 nodules was changed to follow-up for nodules 2.5 cm or larger, seven additional malignant nodules and 316 additional benign nodules would receive a recommendation for follow-up. If the current size threshold (1.5 cm) used to recommend US follow-up for TR3 nodules was decreased to 1.0 cm, seven additional malignant nodules and 118 additional benign nodules would receive a recommendation for follow-up. CONCLUSION. With use of the ACR TI-RADS, most malignant nodules that would not be biopsied would undergo US follow-up, would be smaller than 1 cm, or would both undergo US follow-up and be smaller than 1 cm. Adjusting size thresholds to decrease the number of missed malignant nodules that are 1 cm or larger would result in a substantial increase in the number of benign nodules undergoing follow-up.


Asunto(s)
Carcinoma Papilar Folicular/diagnóstico por imagen , Carcinoma Papilar Folicular/patología , Cáncer Papilar Tiroideo/diagnóstico por imagen , Cáncer Papilar Tiroideo/patología , Nódulo Tiroideo/diagnóstico por imagen , Nódulo Tiroideo/patología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Biopsia con Aguja Fina , Femenino , Humanos , Masculino , Persona de Mediana Edad , Selección de Paciente , Estudios Retrospectivos , Ultrasonografía , Adulto Joven
5.
AJR Am J Roentgenol ; 214(4): 885-892, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31967504

RESUMEN

OBJECTIVE. The purpose of this study was to explore whether a quantitative framework can be used to sonographically differentiate benign and malignant thyroid nodules at a level comparable to that of experts. MATERIALS AND METHODS. A dataset of ultrasound images of 92 biopsy-confirmed nodules was collected retrospectively. The nodules were delineated and annotated by two expert radiologists using the standardized Thyroid Imaging Reporting and Data System lexicon of the American College of Radiology. In the framework studied, quantitative features of echogenicity, texture, edge sharpness, and margin curvature properties of thyroid nodules were analyzed in a regularized logistic regression model to predict malignancy of a nodule. The framework was validated by leave-one-out cross-validation technique, and ROC AUC, sensitivity, and specificity were used to compare with those obtained with six expert annotation-based classifiers. RESULTS. The AUC of the proposed method was 0.828 (95% CI, 0.715-0.942), which was greater than or comparable to that of the expert classifiers, for which the AUC values ranged from 0.299 to 0.829 (p = 0.99). Use of the proposed framework could have avoided biopsy of 20 of 46 benign nodules in a curative strategy (at sensitivity of 1, statistically significantly higher than three expert classifiers) or helped identify 10 of 46 malignancies in a conservative strategy (at specificity of 1, statistically significantly higher than five expert classifiers). CONCLUSION. When the proposed quantitative framework was used, thyroid nodule malignancy was predicted at the level of expert classifiers. Such a framework may ultimately prove useful as the basis for a fully automated system of thyroid nodule triage.


Asunto(s)
Diagnóstico por Computador/métodos , Neoplasias de la Tiroides/diagnóstico por imagen , Nódulo Tiroideo/diagnóstico por imagen , Triaje , Ultrasonografía/métodos , Adulto , Anciano , Anciano de 80 o más Años , Biopsia , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Medición de Riesgo , Neoplasias de la Tiroides/patología , Nódulo Tiroideo/patología
6.
Med Educ ; 54(7): 637-642, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32119145

RESUMEN

OBJECTIVES: Implicit bias is common and is thought to drive discriminatory behaviour. Having previously demonstrated discrimination against specific applicant demographics by academic radiology departments in a simulated resident selection process, the authors sought to better understand the relationship between implicit bias and discrimination, as well as the potential and mechanisms for their mitigation. METHODS: A total of 51 faculty reviewers at three academic radiology departments, who had participated in a 2017 audit study in which they were shown to treat applicants differently based on race or ethnicity and physical appearance, were invited to complete testing for implicit racial and weight bias using the Implicit Association Test in 2019. Respondents were also surveyed regarding awareness of their own personal racial and weight biases, as well as any prior participation in formal diversity training. Comparisons were made between implicit bias scores and applicant ratings, as well as between diversity training and self-awareness of bias. RESULTS: A total of 31 out of 51 faculty reviewers (61%) completed and submitted results of race and weight Implicit Association Tests. A total of 74% (23/31) reported implicit anti-obese bias, concordant with discrimination demonstrated in the resident selection simulation, in which obese applicants were rated 0.40 standard deviations (SDs) lower than non-obese applicants (P < .001). A total of 71% (22/31) reported implicit anti-Black bias, discordant with application ratings, which were 0.47 SDs higher for Black than for White applicants (P < .001). A total of 84% (26/31) of participants reported feeling self-aware of potential racial bias at the time of application review, significantly higher than the 23% (7/31) reporting self-awareness of potential anti-obese bias (P < .001). Participation in formal diversity training was not associated with implicit anti-Black or anti-fat bias, nor with self-reported awareness of potential racial or weight-based bias (all P > .2). CONCLUSIONS: These findings suggest that implicit bias, as measured by the Implicit Association Test, does not inevitably lead to discrimination, and that personal awareness of implicit biases may allow their mitigation.


Asunto(s)
Racismo , Radiología , Negro o Afroamericano , Etnicidad , Humanos , Población Blanca
7.
AJR Am J Roentgenol ; 210(4): 860-865, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29446670

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate thyroid nodule margins for specific morphologic features and determine the diagnostic performance of these features in differentiating papillary carcinoma from benign thyroid nodules. MATERIALS AND METHODS: Nodules measuring 1-3 cm in largest diameter that had been evaluated with high-resolution ultrasound (12-18 MHz) and ultrasound-guided biopsy with definitive pathologic diagnosis were analyzed. Three blinded board-certified readers evaluated high-resolution images of each nodule for jagged edges, lobulated borders, and curved borders along their margins. Reader interpretations were correlated with the pathologic diagnosis to determine the diagnostic performance of each feature. A board-certified pathologist analyzed 10 randomly selected nodules with jagged edges by slide review to evaluate for structural correlation with the imaging finding. RESULTS: The diagnostic performance of jagged edges in papillary carcinoma of the thyroid was 67.4% sensitive and 78.3% specific (odds ratio, 7.44; p < 0.001) for malignancy. Jagged edges correlated with infiltrative variant expansion at slide review. Lobulated borders had sensitivity of 76.1% and specificity of 60.9% for papillary carcinoma (odds ratio, 4.95; p = 0.001) for malignancy. Curved borders were not a significant predictor of papillary carcinoma. CONCLUSION: Jagged edges and lobulated borders of thyroid nodule margins are statistically significant predictors of papillary carcinoma of the thyroid. Jagged edges correlate with infiltrative-type expansion and may be useful predictors of more aggressive papillary carcinomas.


Asunto(s)
Carcinoma Papilar/diagnóstico por imagen , Neoplasias de la Tiroides/diagnóstico por imagen , Nódulo Tiroideo/diagnóstico por imagen , Ultrasonografía/métodos , Anciano , Carcinoma Papilar/patología , Diagnóstico Diferencial , Femenino , Humanos , Biopsia Guiada por Imagen , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad , Neoplasias de la Tiroides/patología , Nódulo Tiroideo/patología
8.
AJR Am J Roentgenol ; 210(5): 1148-1154, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29629797

RESUMEN

OBJECTIVE: The American College of Radiology (ACR) Thyroid Imaging Reporting and Data System (TI-RADS) provides guidelines to practitioners who interpret sonographic examinations of thyroid nodules. The purpose of this study is to compare the ACR TI-RADS system with two other well-established guidelines. MATERIALS AND METHODS: The ACR TI-RADS, the Korean Society of Thyroid Radiology (KSThR) Thyroid Imaging Reporting and Data System (TIRADS), and the American Thyroid Association guidelines were compared using 3422 thyroid nodules for which pathologic findings were available. The composition, echogenicity, margins, echogenic foci, and size of the nodules were assessed to determine whether a recommendation would be made for fine-needle aspiration or follow-up sonography when each system was used. The biopsy yield of malignant findings, the yield of follow-up, and the percentage of malignant and benign nodules that would be biopsied were determined for all nodules and for nodules 1 cm or larger. RESULTS: The percentage of nodules that could not be classified was 0%, 3.9%, and 13.9% for the ACR TI-RADS, KSThR TIRADS, and ATA guidelines, respectively. The biopsy yield of malignancy was 14.2%, 10.2%, and 10.0% for nodules assessed by the ACR TI-RADS, KSThR TIRADS, and ATA guidelines, respectively. The percentage of malignant nodules that were biopsied was 68.2%, 78.7%, and 75.9% for the ACR TI-RADS, the KSThR TIRADS, and the ATA guidelines, respectively, whereas the percentage of malignant nodules that would be either biopsied or followed was 89.2% for the ACR TI-RADS. The percentage of benign nodules that would be biopsied was 47.1%, 79.7%, and 78.1% for the ACR TI-RADS, the KSThR TIRADS, and the ATA guidelines, respectively. The percentage of benign nodules that would be either biopsied or followed was 65.2% for the ACR TI-RADS. CONCLUSION: The ACR TI-RADS performs well when compared with other well-established guidelines.


Asunto(s)
Guías de Práctica Clínica como Asunto , Neoplasias de la Tiroides/diagnóstico por imagen , Nódulo Tiroideo/diagnóstico por imagen , Humanos , República de Corea , Sociedades Médicas , Neoplasias de la Tiroides/patología , Nódulo Tiroideo/patología , Estados Unidos
9.
AJR Am J Roentgenol ; 208(6): 1331-1341, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28402167

RESUMEN

OBJECTIVE: Guidelines for managing thyroid nodules are highly dependent on risk stratification based on sonographic findings. The purpose of this study is to evaluate the risk stratification system used by the American College of Radiology Thyroid Imaging Reporting and Data System (TIRADS). MATERIALS AND METHODS: Patients with thyroid nodules who underwent sonography and fine-needle aspiration were enrolled in a multiinstitutional study. The sonographic nodule features evaluated in the study were composition, echogenicity, margins, and echogenic foci. Images were reviewed by two radiologists who were blinded to the results of cytologic analysis. Nodules were assigned points for each feature, and the points were totaled to determine the final TIRADS level (TR1-TR5). The risk of cancer associated with each point total and final TIRADS level was determined. RESULTS: A total of 3422 nodules, 352 of which were malignant, were studied. The risk of malignancy was closely associated with the composition, echogenicity, margins, and echogenic foci of the nodules (p < 0.0001, in all cases). An increased aggregate risk of nodule malignancy was noted as the TIRADS point level increased from 0 to 10 (p < 0.0001) and as the final TIRADS level increased from TR1 to TR5 (p < 0.0001). Of the 3422 nodules, 2948 (86.1%) had risk levels that were within 1% of the TIRADS risk thresholds. Of the 474 nodules that were more than 1% outside these thresholds, 88.0% (417/474) had a risk level that was below the TIRADS threshold. CONCLUSION: The aggregate risk of malignancy for nodules associated with each individual TIRADS point level (0-10) and each final TIRADS level (TR1-TR5) falls within the TIRADS risk stratification thresholds. A total of 85% of all nodules were within 1% of the specified TIRADS risk thresholds.


Asunto(s)
Guías de Práctica Clínica como Asunto , Radiología/normas , Nódulo Tiroideo/clasificación , Nódulo Tiroideo/diagnóstico por imagen , Ultrasonografía/normas , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Medición de Riesgo/normas , Sensibilidad y Especificidad , Sociedades Médicas/normas , Nódulo Tiroideo/patología , Estados Unidos , Adulto Joven
10.
Radiographics ; 37(5): 1461-1482, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28753381

RESUMEN

Targeted cancer therapies encompass an exponentially growing number of agents that involve a myriad of molecular pathways. To excel within this rapidly changing field of clinical oncology, radiologists must eschew traditional organ system-based approaches of cataloging adverse effects in favor of a conceptual framework that incorporates molecular mechanisms and associated clinical outcomes. Understanding molecular mechanisms that underlie imaging manifestations of adverse effects and known associations with treatment response allows radiologists to more effectively recognize adverse effects and differentiate them from tumor progression. Radiologists can therefore more effectively guide oncologists in the management of adverse effects and treatment decisions regarding continuation or cessation of drug therapy. Adverse effects from targeted cancer therapies can be classified into four categories: (a) category 1, on-target adverse effects associated with treatment response; (b) category 2, on-target adverse effects without associated treatment response; (c) category 3, off-target adverse effects; and (d) category 4, tumor necrosis-related adverse effects. This review focuses on adverse effects primarily within the abdomen and pelvis classified according to established or hypothesized molecular mechanisms and illustrated with images of classic examples and several potential emerging toxic effects. ©RSNA, 2017.


Asunto(s)
Abdomen/diagnóstico por imagen , Antineoplásicos/efectos adversos , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos/clasificación , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos/diagnóstico por imagen , Terapia Molecular Dirigida/efectos adversos , Neoplasias/tratamiento farmacológico , Humanos
11.
J Ultrasound Med ; 36(4): 725-730, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28026900

RESUMEN

OBJECTIVES: To determine whether hepatic arterial and portal venous Doppler ultrasound measurements of the liver in cirrhotic patients correlate with patients' Model for End-Stage Liver Disease (MELD) scores, splenomegaly, or ascites. MATERIALS AND METHODS: Sonographic images and reports were reviewed of 264 patients with hepatic cirrhosis who underwent abdominal ultrasound with Doppler in this internal review board-approved retrospective study. MELD scores were recorded at the time of ultrasound. On gray-scale ultrasound, spleen length was measured and the presence of ascites was noted. Hepatic arterial velocity (HAv) with angle correction, hepatic arterial resistive index, and portal vein velocity with angle correction were measured on Doppler ultrasound. Correlation of hepatic arterial and portal venous Doppler values with MELD score, presence of splenomegaly, and presence of ascites was tested using linear or binary logistic regression analysis. Diagnostic performance of Doppler parameters for high-risk MELD was assessed. RESULTS: The HAv statistically significantly correlated with the MELD score (P = .0001), spleen size (P =.027), and presence of ascites (P =.0001), whereas the hepatic arterial resistive index and portal vein velocity did not correlate with these factors. For MELD scores greater than 19, an HAv greater than 120 cm/s showed accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of 74, 42, 90, 67, and 76%, respectively. With an HAv greater than 160 cm/s, the odds ratio for MELD scores greater than 19 was 42.1. CONCLUSIONS: We found a statistically significant correlation with elevated HAv and increasing MELD scores, splenomegaly, and presence of ascites in patients with cirrhotic liver disease; this may be a useful imaging biomarker in the evaluation of patients with cirrhosis.


Asunto(s)
Enfermedad Hepática en Estado Terminal/diagnóstico por imagen , Arteria Hepática/diagnóstico por imagen , Cirrosis Hepática/diagnóstico por imagen , Vena Porta/diagnóstico por imagen , Ultrasonografía Doppler/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Hígado/irrigación sanguínea , Hígado/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad , Adulto Joven
12.
J Ultrasound Med ; 35(11): 2381-2387, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27629758

RESUMEN

OBJECTIVES: To evaluate the interrupted mucosa sign for identification of endometrial polyps, using pathologic confirmation as the reference standard, compared to other accepted sonographic findings. METHODS: We reviewed 195 patients referred for pelvic sonographic evaluations for suspected endometrial polyps in this retrospective Institutional Review Board-approved study. Of these, 82 had tissue sampling of the endometrium and constituted the final study group. Patient data, including age, menopausal status, last menstrual period, and final pathologic diagnosis, were recorded. Sonograms were reviewed by 2 blinded board-certified radiologists for endometrial features, including thickness, echogenicity, vascularity, presence of a mass, and the interrupted mucosa sign. Descriptive statistics and multivariate logistic regression analysis were performed. RESULTS: The mean age of the patients was 44.99 (SD, 9.88) years, 79.1% of whom were premenopausal. Pathologic diagnosis confirmed polyps in 58 (70.73%). A single feeding vessel was visualized in 36 patients with polyps (62.07%), whereas the interrupted mucosa sign was visualized in 34 (58.62%). The presence of a feeding vessel, the interrupted mucosa sign, or both detected 48 (82.76%) of the polyps. In the multivariate analysis, only the interrupted mucosa sign was a statistically significant predictor of pathologic diagnosis of a polyp (P= .035), with an odds ratio of 3.83 (95% confidence interval, 1.10-13.29). Other sonographic findings were not independent predictors of a polyp: mass (P = .35), single feeding vessel (P = .31), endometrial thickness (P = .88), and endometrial echogenicity (P = .45). The sensitivity, specificity, and positive predictive value of the interrupted mucosa sign were 59%, 75%, and 85%, respectively. CONCLUSIONS: The interrupted mucosa sign is a promising sonographic sign for identification of endometrial polyps, with greater predictive power than previously described signs. It has the potential to improve the diagnostic performance of sonography, especially when used in combination with other described signs.


Asunto(s)
Neoplasias Endometriales/diagnóstico por imagen , Pólipos/diagnóstico por imagen , Ultrasonografía , Adulto , Endometrio/diagnóstico por imagen , Femenino , Humanos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad
13.
AJR Am J Roentgenol ; 204(3): 519-26, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25714280

RESUMEN

OBJECTIVE. The purpose of this article is to evaluate the hypothesis that Alvarado scores of 3 or lower identify adult patients who are unlikely to benefit from CT after appendiceal ultrasound fails to show the appendix and is otherwise normal. MATERIALS AND METHODS. We identified 119 consecutive adults for whom the appendix was not seen on otherwise normal appendiceal sonography performed as the first imaging study for suspected appendicitis, who subsequently underwent CT within 48 hours, and whose data permitted retrospective calculation of admission Alvarado scores. Specific benefits of CT were defined as diagnoses of appendicitis or significant alternative findings, and specific benefits were compared between patients with Alvarado scores of 3 or less and 4 or higher. Significant alternative findings on CT were findings other than appendicitis that were treated with medical or surgical therapy during the admission or that were to be addressed during follow-up care. Diagnostic reference standards were discharge diagnoses, pathologic examinations, and clinical follow-up. RESULTS. No patients (0.0%, 0/49) with Alvarado scores 3 or lower had appendicitis, compared with 17.1% (12/70) of patients with Alvarado scores 4 or higher (p = 0.001), and CT showed neither appendicitis nor significant alternative findings in 85.7% (42/49) versus 58.6% (41/70) of these patients, respectively (p = 0.002). The rates of perforated appendicitis, as well as significant alternative CT findings, did not differ significantly. CONCLUSION. Adults with Alvarado scores 3 or lower who have nonvisualized appendixes and otherwise normal appendiceal sonography are at very low risk for appendicitis or significant alternative findings and therefore are not likely to benefit from CT.


Asunto(s)
Apendicitis/diagnóstico , Apéndice/diagnóstico por imagen , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Adulto , Femenino , Humanos , Masculino , Estudios Retrospectivos , Medición de Riesgo , Ultrasonografía
14.
Abdom Imaging ; 40(7): 2683-9, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25862548

RESUMEN

OBJECT OF STUDY: Retained products of conception (RPOC) displays variable vascularity, ranging from avascular to markedly vascular on color Doppler sonography. We hypothesize that variability in sonographic vascularity may be due to histopathologic variation in the placental tissue. MATERIALS, METHODS, AND PROCEDURES: After institutional review board approval, sonographic images and pathologic specimens were retrospectively reviewed in 26 patients with pathologically proven RPOC. Ultrasound (US) images were scored 0-3 for the degree of vascularity by two radiologists blinded to the diagnosis. Corresponding pathologic specimens were evaluated for vascularization of chorionic villi, degree of inflammation, morphology of maternal arteries, chorionic villous preservation, and percentage of clot, membranes, chorionic villi, and decidua/myometrium. Statistical analysis, including multiple linear regression, was performed. RESULTS: RPOC with histologically avascular chorionic villi or those with markedly reduced vascularization had significantly lower US vascularity scores (p = 0.030) than those with chorionic villi showing normal or decreased vascularization. Sonographically avascular RPOC had a significantly lower percentage villi (p = 0.028) and higher percentage of decidua (p = 0.004) than specimens where US showed any Doppler vascularity. Histologic vascularity of villi (p = 0.049) and non-observation of maternal arteries (p = 0.001) were significant predictors of US vascularity scores in multivariate linear regression analysis, while inflammation of villi (p = 0.053) was a marginally significant predictor. SIGNIFICANCE OF THE CONCLUSIONS: Histologic vascularity of villi appears to contribute to the observed variation in sonographic vascularity. This finding may underlie known differences in clinical outcomes between sonographic vascularity groups.


Asunto(s)
Placenta/diagnóstico por imagen , Ultrasonografía Doppler en Color , Adolescente , Adulto , Vellosidades Coriónicas/diagnóstico por imagen , Vellosidades Coriónicas/patología , Femenino , Fertilización , Humanos , Persona de Mediana Edad , Placenta/patología , Embarazo , Radiografía , Estudios Retrospectivos , Adulto Joven
15.
J Ultrasound Med ; 34(5): 767-74, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25911708

RESUMEN

OBJECTIVES: To determine whether radiologic assessment of thyroid nodules can potentially help guide clinical management after a cytologic diagnosis of atypia of undetermined significance or a follicular lesion of undetermined significance. METHODS: We identified 41 patients with 41 thyroid nodules initially diagnosed as atypia or follicular lesions of undetermined significance on fine-needle aspiration that were subsequently definitively diagnosed by either surgical resection or repeated fine-needle aspiration. All sonograms of nodules were reviewed by 2 blinded board-certifiedradiologists. Lesions were assessed in 3 ways: (1) Mayo pattern classification as benign, indeterminate, or worrisome for malignancy (Ultrasound Q 2005; 21:157-165); (2) thyroid imaging reporting and data system scores (scale of 1-5) based on 2 different previously published scoring criteria (Park et al [Thyroid 2009; 19:1257-1264] and Kwak et al [Radiology 2011; 260:892-899]); and (3) binary classification as benign or malignant. RESULTS: Of the 41 nodules, 25 had benign histologic findings, and 16 were malignant. Mayo pattern classification was 100% accurate for the benign score. Lesions with a Mayo score of indeterminate were malignant in 21% of cases (6 of 28) and benign in 79% (22 of 28). Lesions with a Mayo score of malignant were malignant in 91% of cases (10 of 11) and benign in 9% (1 of 11). Thyroid imaging reporting and data system scores had area under the receiver operating characteristic curve values of 0.827 for Park scores and 0.822 for Kwak scores. Radiologist binary classification of thyroid nodules showed 88% overall accuracy. CONCLUSIONS: Radiologist assessment of thyroid nodules in cases of atypia of undetermined significance or follicular lesions of undetermined significance is highly predictive of the final diagnosis and can help guide management of thyroid nodules of these pathologic types.


Asunto(s)
Adenocarcinoma Folicular/diagnóstico , Biopsia con Aguja Fina , Nódulo Tiroideo/diagnóstico , Ultrasonografía/métodos , Adenocarcinoma Folicular/clasificación , Adulto , Anciano , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Pronóstico , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Nódulo Tiroideo/clasificación
16.
J Ultrasound Med ; 34(12): 2225-30, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26518279

RESUMEN

OBJECTIVES: To identify and evaluate sonographic features suggestive of extracapsular extension in papillary thyroid cancer. METHODS: Three board-certified radiologists blinded to the final pathologic tumor stage reviewed sonograms of pathologically proven cases of papillary thyroid cancer for the presence of extracapsular extension. The radiologists evaluated the following features: capsular abutment, bulging of the normal thyroid contour, loss of the echogenic capsule, and vascularity extending beyond the capsule. RESULTS: A total of 129 cases of pathologically proven thyroid cancer were identified. Of these, 51 were excluded because of lack of preoperative sonography, and 16 were excluded because of pathologic findings showing anaplastic carcinoma, follicular carcinoma, or microcarcinoma (<10 mm). The final analysis group consisted of 62 patients with papillary thyroid carcinoma, 16 of whom had pathologically proven extracapsular extension. The presence of capsular abutment had 100% sensitivity for detection of extracapsular extension. Conversely, lack of capsular abutment had a 100% negative predictive value (NPV) for excluding extracapsular extension. Contour bulging had 88% sensitivity for detection of extracapsular extension and when absent had an 87% NPV. Loss of the echogenic capsule was the best predictor of the presence of extracapsular extension, with an odds ratio of 10.23 (P = .034). This sonographic finding had 75% sensitivity, 65% specificity, and an 88% NPV. Vascularity beyond the capsule had 89% specificity but sensitivity of only 25%. CONCLUSIONS: Sonographic features of capsular abutment, contour bulging, and loss of the echogenic thyroid capsule have excellent predictive value for excluding or detecting extracapsular extension and may help in biopsy selection, surgical planning, and treatment of patients with papillary thyroid cancer.


Asunto(s)
Carcinoma/diagnóstico por imagen , Carcinoma/patología , Invasividad Neoplásica/diagnóstico por imagen , Invasividad Neoplásica/patología , Neoplasias de la Tiroides/diagnóstico por imagen , Neoplasias de la Tiroides/patología , Ultrasonografía/métodos , Anciano , Anciano de 80 o más Años , Carcinoma Papilar , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Método Simple Ciego , Cáncer Papilar Tiroideo , Glándula Tiroides/diagnóstico por imagen
17.
J Digit Imaging ; 28(2): 213-23, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25183580

RESUMEN

Perfusion CT of the liver typically involves scanning the liver at least 20 times, resulting in a large radiation dose. We developed and validated a simplified model of tumor blood supply that can be applied to standard triphasic scans and evaluated whether this can be used to distinguish benign and malignant liver lesions. Triphasic CTs of 46 malignant and 32 benign liver lesions were analyzed. For each phase, regions of interest were drawn in the arterially enhancing portion of each lesion, as well as the background liver, aorta, and portal vein. Hepatic artery and portal vein blood supply coefficients for each lesion were then calculated by expressing the enhancement curve of the lesion as a linear combination of the enhancement curves of the aorta and portal vein. Hepatocellular carcinoma (HCC) and hypervascular metastases, on average, both had increased hepatic artery coefficients compared to the background liver. Compared to HCC, benign lesions, on average, had either a greater hepatic artery coefficient (hemangioma) or a greater portal vein coefficient (focal nodular hyperplasia or transient hepatic attenuation difference). Hypervascularity with washout is a key diagnostic criterion for HCC, but it had a sensitivity of 72 % and specificity of 81 % for diagnosing malignancy in our diverse set of liver lesions. The sensitivity for malignancy was increased to 89 % by including enhancing lesions that were hypodense on all phases. The specificity for malignancy was increased to 97 % (p = 0.039) by also examining hepatic artery and portal vein blood supply coefficients, while maintaining a sensitivity of 76 %.


Asunto(s)
Carcinoma Hepatocelular/irrigación sanguínea , Carcinoma Hepatocelular/diagnóstico por imagen , Imagenología Tridimensional , Neoplasias Hepáticas/irrigación sanguínea , Neoplasias Hepáticas/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Carcinoma Hepatocelular/clasificación , Carcinoma Hepatocelular/cirugía , Ablación por Catéter/métodos , Medios de Contraste , Femenino , Arteria Hepática/diagnóstico por imagen , Humanos , Modelos Lineales , Hígado/irrigación sanguínea , Hígado/patología , Neoplasias Hepáticas/clasificación , Neoplasias Hepáticas/cirugía , Masculino , Vena Porta/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Estudios Retrospectivos , Sensibilidad y Especificidad , Resultado del Tratamiento
18.
Radiographics ; 33(3): 781-96, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23674774

RESUMEN

Retained products of conception (RPOC) are a common and treatable complication after delivery or termination of pregnancy. The pathologic diagnosis of RPOC is made based on the presence of chorionic villi, which indicates persistent placental or trophoblastic tissue. In the setting of postpartum hemorrhage, however, distinguishing RPOC from bleeding related to normal postpartum lochia or uterine atony can be clinically challenging. Ultrasonographic (US) evaluation can be particularly helpful in these patients, and a thickened endometrial echo complex (EEC) or a discrete mass in the uterine cavity is a helpful gray-scale US finding that suggests RPOC. However, gray-scale US findings alone are inadequate for accurate diagnosis. Detection of vascularity in a thickened EEC or an endometrial mass at color or power Doppler US increases the positive predictive value for the diagnosis of RPOC. Computed tomography or magnetic resonance imaging may be helpful when US findings are equivocal and typically demonstrates an enhancing intracavitary mass in patients with RPOC. Diagnostic pitfalls are rare but may include highly vascular RPOC, which can be mistaken for a uterine arteriovenous malformation; true arteriovenous malformations of the uterus; invasive moles; blood clot; and subinvolution of the placental implantation site.


Asunto(s)
Aumento de la Imagen/métodos , Retención de la Placenta/diagnóstico por imagen , Retención de la Placenta/patología , Hemorragia Posparto/diagnóstico por imagen , Hemorragia Posparto/patología , Ultrasonografía/métodos , Diagnóstico Diferencial , Femenino , Humanos , Embarazo
19.
Adv Biol (Weinh) ; 7(8): e2300091, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37403275

RESUMEN

Ovarian cancer is the fifth leading cause of cancer-related deaths in women and the most lethal gynecologic cancer. It is curable when discovered at an early stage, but usually remains asymptomatic until advanced stages. It is crucial to diagnose the disease before it metastasizes to distant organs for optimal patient management. Conventional transvaginal ultrasound imaging offers limited sensitivity and specificity in the ovarian cancer detection. With molecularly targeted ligands addressing targets, such as kinase insert domain receptor (KDR), attached to contrast microbubbles, ultrasound molecular imaging (USMI) can be used to detect, characterize and monitor ovarian cancer at a molecular level. In this article, the authors propose a standardized protocol is proposed for the accurate correlation between in- vivo transvaginal KDR-targeted USMI and ex vivo histology and immunohistochemistry in clinical translational studies. The detailed procedures of in vivo USMI and ex vivo immunohistochemistry are described for four molecular markers, CD31 and KDR with a focus on how to enable the accurate correlation between in vivo imaging findings and ex vivo expression of the molecular markers, even if not the entire tumor could can be imaged by USMI, which is not an uncommon scenario in clinical translational studies. This work aims to enhance the workflow and the accuracy of characterization of ovarian masses on transvaginal USMI using histology and immunohistochemistry as reference standards, which involves sonographers, radiologists, surgeons, and pathologists in a highly collaborative research effort of USMI in cancer.


Asunto(s)
Imagen Molecular , Neoplasias Ováricas , Femenino , Humanos , Inmunohistoquímica , Ultrasonografía/métodos , Imagen Molecular/métodos , Microburbujas , Neoplasias Ováricas/diagnóstico por imagen
20.
Acad Radiol ; 30(11): 2728-2733, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37059613

RESUMEN

RATIONALE AND OBJECTIVES: To inform the development of a job description for Vice-Chairs for academic affairs (VCAA), members of the Alliance of Leaders in Academic Affairs in Radiology (ALAAR) were surveyed to better understand their current job responsibilities and how they would ideally allocate their professional time. MATERIALS AND METHODS: Based on a survey of 33 university-affiliated radiology departments and discussion among ALAAR members, the authors developed a detailed job description for the VCAA. The 21-question survey was composed and validated by experts in the field. It was distributed to all members of ALAAR via email with an electronic link and was open for 5 months. Results of the survey were tabulated, and a job description was crafted to represent the foundational roles of academic affairs leaders in radiology. RESULTS: The response rate for institutions represented in ALAAR was 73% (33/45). All participants reported that they practiced in a university-affiliated institution. Faculty size varied from ≤49 (30.3%, 10/33), 50-99 faculty (24.2%, 8/33), and ≥100 faculty members (45.5%, 15/33). Only 24% of survey respondents had a detailed job description at the time of hire. More than 40% attested to significant oversight over faculty development programs (45%), mentorship programs (42%, and promotions (45%). Respondents ideally want increased oversight (defined as >10%) over exit interviews, faculty awards, promotions, onboarding, recruitment and hiring, and wellness programming. CONCLUSION: The aspirational mission of the VCAA is to oversee components of sequential stages in the professional lifecycle of faculty members but a common job description for this role is lacking.


Asunto(s)
Centros Médicos Académicos , Radiología , Humanos , Docentes , Radiografía , Instituciones de Salud , Docentes Médicos , Liderazgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA