Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Am J Obstet Gynecol ; 2024 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-38842845

RESUMEN

BACKGROUND: Optimal management of fetuses diagnosed as small for gestational age based on an estimated fetal weight of <10th percentile represents a major clinical problem. The standard approach is to increase fetal surveillance with serial biometry and antepartum testing to assess fetal well-being and timing of delivery. Observational studies have indicated that maternal rest in the left lateral position improves maternal cardiac output and uterine blood flow. However, maternal bed rest has not been recommended based on the results of a randomized clinical trial that showed that maternal rest does not improve fetal growth in small-for-gestational-age fetuses. This study was conducted to revisit this question. OBJECTIVE: This study aimed to determine whether maternal bed rest was associated with an increase in the fetal biometric parameters that reflect growth after the diagnosis of a small-for-gestational-age fetus. STUDY DESIGN: A retrospective study was conducted on fetuses who were diagnosed as small for gestational age because of an estimated fetal weight of <10th percentile for gestational age. The mothers were asked to rest in the left lateral recumbent position. Fetal biometry was performed 2 weeks after the diagnosis. All fetuses before entry into the study had a previous ultrasound that demonstrated an estimated fetal weight of >10th percentile. To assess the response to bed rest, the change in fetal biometric parameters (estimated fetal weight, head circumference, abdominal circumference, and femur length) after the recommendation of bed rest was computed for 2 periods: (1) before the diagnosis of a weight of <10th percentile vs at the time of diagnosis of a weight of <10th percentile and (2) at the time of diagnosis of a weight of <10th percentile vs 2 weeks after maternal bed rest. For repeated measures, proportions were compared using the McNemar test, and percentile values were compared using the Kruskal-Wallis test. A P value of <.05 was considered significant. To describe changes in the estimated fetal weight without bed rest, 2 control groups in which the mothers were not placed on bed rest after the diagnosis of a small-for-gestational-age fetus were included. RESULTS: A total of 265 fetuses were observed before and after maternal bed rest. The following were observed in this study: (1) after 2 weeks of maternal rest, 199 of 265 fetuses (75%) had a fetal weight of >10th percentile; (2) the median fetal weight percentile increased from 6.8 (interquartile range, 4.4-8.4) to 18.0 (interquartile range, 9.5-29.5) after 2 weeks of bed rest; (3) similar trends were noted for the head circumference, abdominal circumference, and femur length. In the groups of patients who were not asked to be on bed rest, a reassignment to a weight of >10th percentile at a follow-up examination only occurred in 7 of 37 patients (19%) in the Texas-Michigan group and 13 of 111 patients (12%) in the Colorado group compared with the bed rest group (199/265 [75%]) (P<.001). CONCLUSION: Patients who were prescribed 2 weeks of bed rest after the diagnosis of a fetal weight of <10th percentile had an increase in weight of >10th percentile in 199 of 265 fetuses (75%). This increase in fetal weight was significantly higher than that in the 2 control groups in which bed rest was not prescribed. This observation suggests that bed rest improves fetal growth in a subset of patients.

2.
Echocardiography ; 41(7): e15870, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38979798

RESUMEN

Evaluation of the fetal heart involves two approaches. The first describes a screening protocol in which the heart is imaged in transverse planes that includes the four-chamber view (4CV), left and right outflow tracts, and the 3-vessel-tracheal view. The second approach is a fetal echocardiogram that requires additional cardiac images as well as evaluating ventricular function using diagnostic tools such as M-mode and pulsed Doppler ultrasound. Speckle tracking analysis of the ventricular and atrial endocardium of the fetal heart has focused primarily on computing longitudinal global strain. However, the technology enabling this measurement to occur has recently been adapted to enable the clinician to obtain numerous additional measurements of the size, shape, and contractility of the ventricles and atrial chambers. By using the increased number of measurements derived from speckle tracking analysis, we have reported the ability to screen for tetralogy of Fallot, D-transposition of the great arteries (D-TGA), and coarctation of the aorta by only imaging the 4CV. In addition, we have found that measurements derived from speckle tracking analysis of the ventricular and atrial chambers can be used to compute the risk for emergent neonatal balloon atrial septostomy in fetuses with D-TGA. The purpose of this review is to consolidate our experience in one source to provide perspective on the benefits of speckle tracking analysis to measure the size, shape, and contractility of the ventricles and atria imaged in the 4CV in fetuses with congenital heart defects.


Asunto(s)
Corazón Fetal , Cardiopatías Congénitas , Contracción Miocárdica , Ultrasonografía Prenatal , Humanos , Cardiopatías Congénitas/fisiopatología , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/embriología , Ultrasonografía Prenatal/métodos , Corazón Fetal/diagnóstico por imagen , Corazón Fetal/fisiopatología , Contracción Miocárdica/fisiología , Ecocardiografía/métodos , Diagnóstico por Imagen de Elasticidad/métodos , Interpretación de Imagen Asistida por Computador/métodos , Femenino
3.
J Ultrasound Med ; 2024 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-39076048

RESUMEN

OBJECTIVES: In a cohort of patients with estimated fetal weights (EFWs) <10th centile, we aimed 1) to compare the prevalence of abnormalities of fetal 4-chamber view (4CV) cardiac size, shape, and ventricular contractility in fetal growth restricted (FGR) and small-for-gestational-age (SGA) fetuses and 2) to compare umbilical vein flow (UVF) measurements to standard Doppler surveillance in predicting abnormalities of cardiac function. METHODS: Prospective observational cohort study of fetuses with EFW <10th percentile. Measurements of size and shape used were 4CV transverse width, 4CV cardiac area, 4CV global sphericity index, and right-to-left ventricular mid-chamber width ratio. Variables of contractility used were fractional shortening change at the mid-ventricle chamber, global longitudinal strain, fractional area change, and left ventricular cardiac output. The UVF and standard Doppler surveillance including umbilical artery (UA), middle cerebral artery, and cerebroplacental ratio (CPR) were collected. Control data were from previously published studies. RESULTS: A total of 95 fetuses with EFWs <10th centile were included in the study. The rates of abnormalities of cardiac size and shape and ventricular contractility were all significantly elevated compared with normally grown control fetuses but similar between FGR and SGA fetuses. In a subset of 76 patients with UVF data, evaluation UVF identified more patients with any abnormality of contractility compared with UA (37.9 vs 17.2%, P = .02). CONCLUSIONS: The addition of UVF doubled the detection rate of ventricular contractility abnormalities. The addition of UVF should be considered in the surveillance of FGR and SGA fetuses to further stratify the severity of hypoxemia and to identify those at greater risk for future cardiovascular dysfunction.

4.
Am J Obstet Gynecol ; 229(2): 155.e1-155.e18, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36627073

RESUMEN

BACKGROUND: A strong body of evidence has now coalesced indicating that some obstetrical syndromes may result from maladaptive responses of the maternal cardiovascular system. Longitudinal studies have shown that these changes are complex and present before the clinical recognition of preeclampsia and fetal growth restriction, suggesting that hemodynamic maladaptation may play an etiologic role in obstetrical complications. Chronic hypertension is one of the most frequent complications of pregnancy, and recent evidence suggests that control of mild hypertension in early pregnancy improves outcome. The management of chronic hypertension can be improved by understanding specific cardiovascular hemodynamic abnormalities such as increased cardiac output or increased systemic vascular resistance, which can respond to either beta or calcium channel blockers, depending on the hemodynamic findings. Evaluation of maternal cardiac function has not been previously available to obstetrical healthcare providers using diagnostic ultrasound equipment used for fetal evaluation. OBJECTIVE: Obstetrical ultrasound machines may be configured for various probes (endovaginal, abdominal, 3D/4D, and cardiac). This study used a cardiac probe placed in the suprasternal notch to image and measure the descending aorta diameter and the velocity time integral using pulsed and continuous wave Doppler ultrasound in normal pregnant women between 11 and 39 weeks of gestation. These measurements were followed by computation of maternal left ventricular preload, afterload, contractility, and blood flow. STUDY DESIGN: This was a prospective cross-sectional study. A total of 400 pregnant women were recruited between 11 and 39 weeks of gestation. Imaging of the maternal aortic arch was performed by placing a cardiac probe in the suprasternal notch to identify the aortic arch using 2D and color Doppler ultrasound. The end-systolic diameter of the aorta was measured at the junction of the left subclavian artery with the descending aorta, which was followed by insonation of the descending aorta to obtain the Doppler waveform. Following insonation of the descending aorta, measurements of the aortic diameter, velocity time integral, ejection time, mean pressure gradient, heart rate, maternal weight and height, and systolic and diastolic blood pressures were entered into an Excel spreadsheet to compute the following: (1) preload measurements of stroke volume, stroke volume index, and stroke work index; (2) afterload measurements of systemic vascular resistance and the potential-to-kinetic energy ratio; (3) contractility measurements of inotropy and the Smith-Madigan inotropy index; and (4) blood flow measurements of cardiac output and the cardiac output index. Fractional polynomial regression analysis was performed for each of the above measurements using gestational age as the independent variable. RESULTS: The diastolic and mean arterial blood pressure decreased from 11 to 18 weeks of gestation and then increased until term. The afterload measurements demonstrated similar characteristics, as all values decreased from 11 weeks until the mid and late second trimester, after which all values increased until term. Changes in contractility demonstrated an increase from 11 weeks to 25 to 28 weeks, followed by a decline until term. Changes in blood flow demonstrated an increase from 11 to 27 weeks and then declined until term. The continuous wave Doppler values were greater than the pulsed Doppler values except for the contractility measurements. Examples of abnormal cardiac measurements were identified in pregnant patients with hypertension and fetal growth restriction. An Excel calculator was created to provide quick computation of z-score measurements and their corresponding centiles described in this study. CONCLUSION: The technique for evaluation of maternal cardiac function described in this study would allow screening of maternal left ventricular preload, afterload, contractility, and blood flow in the obstetrical clinical milieu once a cardiac probe is acquired for obstetrical ultrasound machines used for fetal evaluation. The above measurements would allow the clinician to select appropriate hypertensive medication on the basis of the results of the evaluation of the maternal left ventricle.


Asunto(s)
Retardo del Crecimiento Fetal , Hipertensión , Embarazo , Humanos , Femenino , Estudios Prospectivos , Valores de Referencia , Obstetras , Estudios Transversales , Gasto Cardíaco/fisiología , Ultrasonografía Prenatal
5.
Echocardiography ; 40(3): 204-216, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36734058

RESUMEN

INTRODUCTION: Speckle tracking analysis was used to evaluate right (RA) and left (LA) atria size, shape and contractility to create a probability calculator to identify fetuses at risk for urgent neonatal balloon atrial septostomy (BAS). METHODS: The study group consisted of 39 fetuses with D-TGA, of which 55% (N = 22) required neonatal BAS and 45% (N = 17) did not. The RA and LA end-diastolic areas, lengths, widths, and sphericity indices as well as global, longitudinal, and transverse contractility were measured with speckle tracking analysis. The z-scores of the measurements were compared to 200 controls. Logistic regression analysis of the computed z-score measurements was performed to separate fetuses requiring urgent neonatal atrial BAS from those who did not. RESULTS: The following z-score values for all fetuses with D-TGA, irrespective of whether they required neonatal BAS, that were significantly less than controls: RA base sphericity index, basal-apical length fractional shortening, fractional area change, lateral wall annular plane systolic excursion (APSE), and longitudinal reservoir strain; LA mid-chamber width, fractional shortening, ejection fraction, basal-apical length fractional shortening, atrial ejection volume, septal wall APSE, and reservoir strain. The following z-score values were significantly larger than control values: RA/LA mid-chamber width, RA/LA base width, and RA mid-chamber length. Logistic regression analysis identified the following five measurements that correctly identified 19 of 22 fetuses requiring urgent neonatal atrial BAS with a sensitivity of 86.4%, a false-positive rate of 11.8% and a positive predictive value of 90.4%: (1) LA mid-chamber transverse fractional shortening, (2) RA mid-chamber end-diastolic width, (3) RA basal-apical length fractional shortening, (4) RA mid-chamber fractional shortening, and (5) RA fractional area change. CONCLUSION: Using the measurements described in this study identified significant differences between all fetuses with D-TGA and controls, as well as identified measurements that predicted the probability of D-TGA fetuses requiring neonatal septostomy.


Asunto(s)
Fibrilación Atrial , Transposición de los Grandes Vasos , Recién Nacido , Femenino , Embarazo , Humanos , Ecocardiografía , Ultrasonografía Prenatal , Corazón Fetal/diagnóstico por imagen , Arterias
6.
J Ultrasound Med ; 42(3): 637-646, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35822424

RESUMEN

OBJECTIVES: The prenatal detection of D-Transposition of the great arteries (D-TGA) and tetralogy of Fallot (TOF) has been reported to be less than 50% to as high as 77% when adding the outflow tracts to the four-chamber screening protocol. Because many examiners still struggle with the outflow tract examination, this study evaluated whether changes in the size and shape of the heart in the 4CV as well as the ventricles occurred in fetuses with D-TGA and TOF could be used to screen for these malformations. METHODS: Forty-four fetuses with the pre-and post-natal diagnosis of D-TGA and 44 with TOF were evaluated between 19 and 36 weeks of gestation in which the 4CV was imaged. Measurements of the end-diastolic width, length, area, and global sphericity index were measured for the four-chamber view and the right and left ventricles. Using z-score computed values, logistic regression was performed between the 88 study and 200 control fetuses using the hierarchical forward selection protocol. RESULTS: Logistic regression identified 10 variables that correctly classified 83/88 of fetuses with TOF and TGA, for a sensitivity of 94%. Six of 200 normal controls were incorrectly classified for a false-positive rate of 3%. The area under the receiver operator classification curve was 98.1%. The true positive rate for D-TGA was 93.2%, with a false-negative rate to 6.8%. The true positive rate for TOF was 95.5%, with a false negative rate of 4.5%. CONCLUSIONS: Measurements of the 4CV and of the RV and LV may help identify fetuses at risk for D-TGA or TOF.


Asunto(s)
Tetralogía de Fallot , Transposición de los Grandes Vasos , Embarazo , Femenino , Humanos , Transposición de los Grandes Vasos/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Tetralogía de Fallot/diagnóstico por imagen , Ecocardiografía/métodos , Arterias , Feto , Ultrasonografía Prenatal/métodos
7.
J Ultrasound Med ; 42(1): 173-183, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35451119

RESUMEN

OBJECTIVES: Umbilical vein flow (UVF) is reduced in fetal growth restriction (FGR). We compared absolute and size-adjusted UVF (estimated fetal weight [EFW] and abdominal circumference [AC]) and rates of abnormal UVF parameters (<10th percentile) among FGR fetuses meeting Delphi criteria (FGR-D) against small for gestational age (SGA) fetuses and appropriate for gestational age (AGA) controls. METHODS: Absolute UVF, UVF/EFW, and UVF/AC were compared between 73 FGR pregnancies (35 FGR-D, 38 SGA) and 108 AGA controls. Rates of abnormal UVF were compared to abnormal umbilical artery pulsatility index (UAPI). Independent samples t-tests, Mann-Whitney U, odds ratio (OR), chi-squared, and Fisher's exact tests were used as appropriate. RESULTS: Mean absolute UVF was significantly decreased in FGR-D compared to AGA (P = .0147), but not between SGA and AGA fetuses. The incidence of both abnormal absolute UVF and UVF/AC values (<10th centile) was higher among late-onset FGR fetuses versus AGA fetuses (UVF: OR 2.7, confidence interval [CI] 1.37-5.4; UVF/AC: OR 2.73, CI 1.37-5.4). UVF was more frequently abnormal than UAPI and in only two fetuses were both Doppler values abnormal. CONCLUSION: Absolute UVF is altered in late-onset FGR, and most pronounced among FGR-D. UVF may provide additional insight into fetal compromise in those affected by growth restriction.


Asunto(s)
Retardo del Crecimiento Fetal , Enfermedades del Recién Nacido , Embarazo , Femenino , Recién Nacido , Humanos , Recién Nacido Pequeño para la Edad Gestacional , Ultrasonografía Prenatal , Peso Fetal , Ultrasonografía Doppler , Edad Gestacional , Arterias Umbilicales/diagnóstico por imagen
8.
Pediatr Cardiol ; 44(6): 1382-1396, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36853336

RESUMEN

INTRODUCTION: Speckle tracking analysis of the endocardium of the right (RV) and left (LV) ventricles was used to evaluate the size, shape, and contractility of these chambers in fetuses with D-Transposition of the great arteries (D-TGA) to identify fetuses that would require emergent balloon atrial septostomy (BAS) after birth. METHODS: This was a retrospective analysis of fetuses with D-TGA and intact ventricular septum that were divided into 2 groups. Group 1 underwent urgent BAS after birth because of a restrictive atrial septum and group 2 did not. Using speckle tracking analysis, the end-diastolic and end-systolic RV and LV areas, lengths, widths, sphericity indices, and contractility were computed. Logistic regression analysis was performed to identify fetuses who would require urgent neonatal BAS. RESULTS: Of the 39 fetuses with D-TGA, 55% (n = 22) required urgent neonatal BAS (group 1) and 45% (n = 17) (group 2) did not. When comparing D-TGA groups 1 and 2, differences were seen in RV and LV area, sphericity index for segment 1 of the LV, LV fractional area of change and free wall annular plane systolic excursion, fractional shortening for LV segment 12, and RV free wall strain. Regression analysis of these measurements identified 91% of neonates who underwent BAS, with a false-positive rate of 12%. CONCLUSION: Using speckle tracking analysis to evaluate the RV and LV, measurable differences were identified for the RV and LV size, shape, and contractility between fetuses who underwent neonatal urgent BAS vs. those who did not require this procedure.


Asunto(s)
Fibrilación Atrial , Transposición de los Grandes Vasos , Recién Nacido , Humanos , Transposición de los Grandes Vasos/diagnóstico por imagen , Transposición de los Grandes Vasos/cirugía , Ecocardiografía/métodos , Estudios Retrospectivos , Ventrículos Cardíacos/diagnóstico por imagen , Corazón Fetal/diagnóstico por imagen , Corazón Fetal/cirugía
9.
Am J Perinatol ; 2023 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-37164318

RESUMEN

OBJECTIVE: The purposes of the study were to develop reference ranges and maturation patterns of fetal cardiac function parameters measured by speckle tracking echocardiography (STE) using multiple biometric variables at 17 to 24 weeks' gestation among Thai fetuses and to compare with other previous reports. STUDY DESIGN: The four-chamber view of the fetal heart in 79 healthy fetuses was suitably analyzed by STE to establish the best-fit regression model. The 95% reference intervals and Z-score equations of fetal cardiac function parameters were computed. RESULTS: The fractional area change of both ventricles, left ventricular (LV) end-diastolic and end-systolic volumes, LV stroke volume, LV cardiac output (CO), and LV CO per kilogram were all increased according to gestational age (GA) and five fetal biometric measurements. However, the global longitudinal strain, basal-apical length fractional shortening (BAL-FS), BAL annular free wall and septal wall FS, BAL free wall and septal wall annular plane systolic excursions, 24-segment transverse width FS, as well as LV ejection fraction were all independent of GA or other somatic characteristics. There were varying development patterns between fetal right and left ventricles of these cardiac function indices across the gestation period. CONCLUSION: Our study created Z-score and corresponding centile calculators, 5th and 95th centile reference tables, and corresponding graphs and determined the normal evolution across gestation using multiple somatic growth and age variables between 17 and 24 gestational weeks. These nomograms serve as an essential prerequisite for quantitatively evaluating fetal cardiac contractility and allow for precisely detecting early changes in the fetal heart function. KEY POINTS: · Most fetal cardiac function measurements were correlated with all the independent variables.. · Fetal ventricular function parameters have their own characteristic maturation changes.. · Racial variability may not occupy an important place for fetal myocardial function during these GA..

10.
Am J Obstet Gynecol ; 226(4): 475-486, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35369904

RESUMEN

Growth-restricted fetuses are at risk of hypoxemia, acidemia, and stillbirth because of progressive placental dysfunction. Current fetal well-being, neonatal risks following delivery, and the anticipated rate of fetal deterioration are the major management considerations in fetal growth restriction. Surveillance has to quantify the fetal risks accurately to determine the delivery threshold and identify the testing frequency most likely to capture future deterioration and prevent stillbirth. From the second trimester onward, the biophysical profile score correlates over 90% with the current fetal pH, and a normal score predicts a pH >7.25 with a 100% positive predictive value; an abnormal score on the other hand predicts current fetal acidemia with similar certainty. Between 30% and 70% of growth-restricted fetuses with a nonreactive heart rate require biophysical profile scoring to verify fetal well-being, and an abnormal score in 8% to 27% identifies the need for delivery, which is not suspected by Doppler findings. Future fetal well-being is not predicted by the biophysical profile score, which emphasizes the importance of umbilical artery Doppler and amniotic fluid volume to determine surveillance frequency. Studies with integrated surveillance strategies that combine frequent heart rate monitoring with biophysical profile scoring and Doppler report better outcomes and stillbirth rates of between 0% and 4%, compared with those between 8% and 11% with empirically determined surveillance frequency. The variations in clinical behavior and management challenges across gestational age are better addressed when biophysical profile scoring is integrated into the surveillance of fetal growth restriction. This review aims to provide guidance on biophysical profile scoring in the in- and outpatient management of fetal growth restriction.


Asunto(s)
Retardo del Crecimiento Fetal , Placenta , Líquido Amniótico , Femenino , Retardo del Crecimiento Fetal/diagnóstico por imagen , Humanos , Recién Nacido , Embarazo , Ultrasonografía , Arterias Umbilicales/diagnóstico por imagen
11.
J Ultrasound Med ; 41(8): 1949-1960, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34792203

RESUMEN

INTRODUCTION: Measurements of the umbilical vein diameter (UVD) and blood flow (mL/min) (UVF) have been demonstrated to be decreased in fetuses with growth restriction (FGR) using gestational age (GA) as the independent variable. However, no previous studies have used the biparietal diameter (BPD), head circumference (HC), abdominal circumference (AC), femur length (FL), and the estimated fetal weight (EFW) to create equations to be used for z-score computations when evaluating fetuses at risk foran abnormal UVD and UVF. METHODS: Two hundred and forty normal fetuses between 20 and 40 weeks of gestation were examined in which the UVD and time averaged maximal velocity (TAMX) were measured from which the UVF, UVF/HC, UVF/AC, and UVF/kg were computed. Fractional polynomial regression analysis was used to compute z-score equations using the above independent variables. Thirty-six fetuses with abnormal growth of the AC were examined to test the validity of the equations. RESULTS: The UVD, TAMX, UVF, UVF/HC, and UVF/AC all increased with gestatonal age and fetal growth except for the UVF/kg, which decreased with age and growth. From the regression equations, two z-score calculators were created using an Excel spreadsheet that can be used in clinical practice. Abnormal measurements of the UVD, UVF, UVF/HC, UVF/AC, and UVF/kg were observed in the 36 study fetuses, 21 with an AC < 10th centile and 15 with an AC > 90th centile. CONCLUSION: Using the equations generated from this study and the z-score calculators provides a clinical tool to measure the size and flow of the umbilical vein that may have clinical implications.


Asunto(s)
Retardo del Crecimiento Fetal , Diagnóstico Prenatal , Venas Umbilicales , Femenino , Retardo del Crecimiento Fetal/diagnóstico por imagen , Edad Gestacional , Humanos , Embarazo , Diagnóstico Prenatal/métodos , Análisis de Regresión , Ultrasonografía Prenatal , Venas Umbilicales/diagnóstico por imagen
12.
J Ultrasound Med ; 41(8): 2041-2057, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34825711

RESUMEN

OBJECTIVES: The purpose of this study was to use speckle tracking analysis to evaluate the size, shape, and function of the atrial chambers in normal fetuses and develop a z-score calculator that can be used in future studies in fetuses at risk for cardiovascular disease. METHODS: The control group consisted of 200 normal fetuses examined between 20 and 40 weeks of gestation in which speckle tracking analysis of right (RA) and left (LA) atrial chambers was performed. The atrial end-diastolic and end-systolic endocardial borders for each chamber were identified from which measurements of atrial length, width, area, and volume were computed. Equations were derived using fractional polynomial regression analysis to compute z-score equations. RESULTS: The LA end-diastolic volume, RA and LA end-diastolic area, length, base width, and mid-chamber widths increased with gestational age and fetal size. Left atrial emptying and ejection volumes increased with gestational age and fetal size. The fractional area change was significantly less for the RA than the LA. The LA base and mid-chamber fractional shortening were significantly greater than the RA. There was a significant difference between the RA and LA global contractile strain. CONCLUSION: Mean and standard deviation equations for each of the measurements described in this study were computed to create a z-score calculator that can be utilized in the clinical environment when evaluating fetuses with suspected atrial pathology that could alter the size, shape, and function of the atrial chambers.


Asunto(s)
Atrios Cardíacos , Ultrasonografía Prenatal , Diástole , Femenino , Feto , Edad Gestacional , Atrios Cardíacos/diagnóstico por imagen , Humanos , Embarazo
13.
J Ultrasound Med ; 41(12): 2955-2964, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35397130

RESUMEN

OBJECTIVES: This study examines fetuses with tetralogy of Fallot (TOF) and evaluates the right (RV) and left (LV) ventricular contractility and LV function using speckle-tracking analysis of the endocardium. METHODS: The study group consisted of 44 fetuses with TOF, of which 34% had pulmonary valve atresia (N = 15) and 59% (N = 26) had pulmonary valve stenosis. The RV and LV global fractional area change, longitudinal contractility (longitudinal strain, free wall strain, septal strain, free wall and septal annular fractional shortening, and free wall and septal wall annular plane systolic excursion), and transverse contractility (24-segment fractional shortening) as well as LV functional assessment (stroke volume, cardiac output, and ejection fraction) were measured using speckle-tracking analysis. The z-scores of the measurements were compared to 200 controls. RESULTS: Compared to controls, measurements of LV contractility in fetuses with TOF demonstrated significantly abnormal values for global contractility, longitudinal contractility, and transverse contractility of the mid and apical segments. LV function was abnormal for stroke volume (SV), cardiac output (CO), and ejection fraction (EF). In comparison, RV contractility demonstrated no significant difference between TOF and control z-score values for RV global contractility. Only two RV measurements were found to be abnormal: longitudinal contractility and transverse contractility of the apical segments. CONCLUSION: Using multiple measurement tools to evaluate global, longitudinal, and transverse contractility, this study identified significant differences between fetuses with TOF and healthy controls, with greater contractility abnormalities seen in the LV than in the RV.


Asunto(s)
Tetralogía de Fallot , Disfunción Ventricular Derecha , Humanos , Tetralogía de Fallot/diagnóstico por imagen , Función Ventricular Izquierda , Ventrículos Cardíacos/diagnóstico por imagen , Volumen Sistólico , Feto , Función Ventricular Derecha
14.
J Ultrasound Med ; 41(12): 2939-2953, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35305032

RESUMEN

OBJECTIVES: One of the problems for the clinician who desires to measure the interventricular septum (IVS) in a high-risk fetus is to know where to make the measurement. The purpose of this study was to use speckle-tracking analysis to measure the IVS area, 24-segment widths, and length at end-diastole (ED) and end-systole (ES) in normal fetuses. METHODS: From the 4-chamber view, speckle-tracking analysis was performed at ED and ES on the IVS in 200 normal fetuses. The following were computed and regressed against gestational age (GA) and fetal biometric (FB) measurements: area, length, and the 24-segment transverse widths from the apex to the crux. The 24-segment width/length ratio was also measured. The speckle-tracking measurements of the ED area and length were compared using a point-to-point measurement tool available on all ultrasound machines. RESULTS: The ED and ES areas, lengths, and 24-segment widths increased with GA and FB. The ED and ES areas were virtually identical. The 24-segment width/length ratio decreased from the apex to the crux of the septum. There was no significant difference in the measurement of the ED area and the length between speckle-tracking and the point-to-point measurements. CONCLUSIONS: Measurement of the area and length of the IVS are simple to obtain and provide a new diagnostic tool to evaluate the fetus at risk for IVS hypertrophy which may be observed in fetuses of mothers with pregestational and gestational diabetes.


Asunto(s)
Corazón Fetal , Tabique Interventricular , Femenino , Embarazo , Humanos , Corazón Fetal/diagnóstico por imagen , Ultrasonografía Prenatal/métodos , Tabique Interventricular/diagnóstico por imagen , Edad Gestacional , Hipertrofia , Ventrículos Cardíacos/diagnóstico por imagen
15.
J Ultrasound Med ; 41(11): 2703-2714, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35142391

RESUMEN

OBJECTIVES: To investigate cardiac size, shape, and ventricular contractility in fetuses with estimated fetal weight (EFW) <10th centile at sea level (Houston). METHODS: A prospective ultrasound study examined 37 fetuses with EFW <10th centile at sea level. High-frequency cine clips were used to evaluate the 4-chamber view including end-diastolic measurements and global sphericity index. The size, shape, and contractility of both ventricles were analyzed with speckle tracking methods. Z scores were calculated using the mean ± standard deviation (SD) derived from normal controls. Measurements were abnormal if their Z score values were <-1.65 or >+1.65. The proportion of small fetuses with abnormal parameters was compared to normal reference ranges. Results were compared to a similar published study of small fetuses at higher altitude in Denver. RESULTS: About one-third of Houston fetuses with EFW <10th centile had enlarged globular shaped 4-chamber hearts with increased right ventricle (RV) area, RV basal-apical length, RV base width, and left ventricle (LV) basal-apical length measurements. Bilateral ventricular hypertrophy was often present. An increased proportion of Houston fetuses had increased ventricular contractility. However, decreased ventricular contractility was more prevalent for higher altitude fetuses. CONCLUSIONS: Third trimester fetuses at sea level, with an EFW <10th centile, were often associated with enlarged and globular-shaped hearts. They had increased global and longitudinal ventricular contractility as compared to controls. Higher altitude fetuses also had enlarged globular-shaped hearts but with a greater proportion of cases having decreased ventricular contractility as compared to the sea level cohort.


Asunto(s)
Corazón Fetal , Ventrículos Cardíacos , Femenino , Embarazo , Humanos , Corazón Fetal/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Ultrasonografía Prenatal/métodos , Estudios Prospectivos , Peso Fetal , Edad Gestacional
16.
Pediatr Cardiol ; 2022 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-36329329

RESUMEN

Fetal echocardiography may be performed because of noncardiac indications (the pregnancy is identified as high risk for fetal cardiac disease), or because of fetal cardiac indications (abnormal fetal heart at the time of a screening ultrasound). Considering recent improvements in fetal cardiac screening over the past decade, the goal of this single institution study was to reconsider the importance of performing fetal echocardiography purely for screening (noncardiac) indications. We performed a retrospective analysis to review screening and fetal cardiac indications and fetal cardiac findings for fetal echocardiograms performed at UCLA between 2015 and 2019. Fetal heart disease was identified in 391 (15%) of 2592 pregnancies in this study. Among these 391 cases, 227 (58%) occurred in low-risk pregnancies (without screening indications). While 79% of the cases of fetal cardiac disease were referred with fetal cardiac indications, 21% of the cases were referred with exclusively screening indications. Fetal cardiac disease was discovered on fetal echocardiograms in 4% of pregnancies referred for exclusively screening indications, but the frequency of fetal cardiac disease following normal fetal cardiac screening has decreased from 6% in 2015 to 3% in 2019. In our population, we recommend continued referral for fetal echocardiography for pregnancies identified as high risk for CHD. However, as fetal cardiac screening continues to improve, referral for fetal echocardiography following normal fetal cardiac screening will have diminishing value and yield.

17.
Fetal Diagn Ther ; 49(1-2): 41-51, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34915477

RESUMEN

INTRODUCTION: The aim of the study was to establish normal reference values obtained by fetal speckle tracking analysis of the fetal heart between 17 and 24 weeks of gestation among Thai fetuses and compare the nomograms with previous studies. METHODS: The 4-chamber view (4CV) of the fetal heart in 79 normal fetuses was analyzed by speckle tracking analysis to determine the best-fit regression model. The 95% reference intervals and Z-score equations of fetal cardiac parameters were computed. RESULTS: The end-diastolic length, width, area, and circumference of the 4CV as well as the ventricular end-diastolic length, 24-segment widths, and area were all increased as a function of gestational age (GA), and 5 fetal biometric parameters. In contrast, the global sphericity index (SI), 24-segment SI, and right ventricle/left ventricle width and area ratios did not change with GA or fetal biometric measurements. There were few differences in Z-score reference ranges of fetal cardiac measurements between the current study and previous studies conducted in different patient populations. CONCLUSION: Our study provided z-score and corresponding centile calculators, 5th and 95th centile reference tables, and corresponding graphs for evaluating the size and shape of the 4CV and the right and left ventricles using 6 independent variables between 17 and 24 weeks of gestation. These results provide normal reference ranges for future studies of fetuses with pathologies that may alter the size and shape of the 4CV and ventricles.


Asunto(s)
Ventrículos Cardíacos , Ultrasonografía Prenatal , Diástole , Femenino , Corazón Fetal/diagnóstico por imagen , Edad Gestacional , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Embarazo , Valores de Referencia , Ultrasonografía Prenatal/métodos
18.
Prenat Diagn ; 41(1): 136-144, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33015877

RESUMEN

INTRODUCTION: This study was designed to evaluate ventricular size, shape, and function in recipient twins following laser therapy for twin-twin transfusion syndrome (TTTS), using novel speckle-tracking techniques. METHODS: This retrospective study enrolled patients that underwent fetal laser surgery for TTTS and had fetal echocardiograms (FE) performed pre- and post-operatively (op), with adequate resolution in the 4-chamber view for analysis, using a speckle-tracking software, to compute the size, shape, and function of both the right (RV) and left (LV) ventricles. Values were indexed to published normal values. Pre- and post-laser Z-score values for each of the measurements were compared using the Student's t-test, with significance defined as P < 0.05. RESULTS: Fifteen TTTS candidate pregnancies that underwent laser therapy between 2010 and 2017, with adequate pre- and post-op FE, were selected for the analysis. Post-op FE at 28.5 ± 8.3 days showed a significant decrease in RV base dimension, increased LV base dimension, and improvements in many functional measurements: LV global and free wall strain, LV fractional area change, LV basal-apical fractional change, and LV and RV 24-segment fractional shortening (FS) of the basal segments. CONCLUSIONS: Cardiac remodeling, following laser surgery in TTTS recipient twins, was demonstrated in the basal portion of both the RV and LV with improved biventricular function.


Asunto(s)
Ecocardiografía/métodos , Corazón Fetal/diagnóstico por imagen , Transfusión Feto-Fetal/cirugía , Remodelación Ventricular , Adulto , Ecocardiografía/estadística & datos numéricos , Femenino , Corazón Fetal/fisiología , Humanos , Terapia por Láser , Embarazo , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
19.
J Ultrasound Med ; 40(9): 1955-1961, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33174649

RESUMEN

This study compared the non-quiver with the quiver technique for identifying the end-systolic and end-diastolic endocardium of the fetal right ventricle (RV) and left ventricle (LV) used for speckle-tracking analysis. Bland-Altman and t test analyses showed no significant differences in measurements between the techniques for the RV and LV. The difference in the time required to perform the non-quiver analysis was significantly longer (P < .001) for the RV and LV than the quiver technique. The quiver technique allows the examiner to efficiently identify the endocardial borders of the fetal heart compared with the non-quiver method.


Asunto(s)
Endocardio , Ventrículos Cardíacos , Diástole , Ecocardiografía , Endocardio/diagnóstico por imagen , Corazón Fetal/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Humanos
20.
J Ultrasound Med ; 40(12): 2537-2548, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33502041

RESUMEN

OBJECTIVE: Prenatal detection rates for tetralogy of Fallot (TOF) vary between 23 and 85.7%, in part because of the absence of significant structural abnormalities of the 4-chamber view (4CV), as well as the relative difficulty in detection of abnormalities during the screening examination of the outflow tracts. The purpose of this study was to evaluate whether the 4CV and ventricles in fetuses with TOF may be characterized by abnormalities of size and shape of these structures. METHODS: This study retrospectively evaluated 44 fetuses with the postnatal diagnosis of TOF. Measurements were made from the 4CV (end-diastolic length, width, area, global sphericity index, and cardiac axis) and the right (RV) and left (LV) ventricles (area, length, 24-segment transverse widths, sphericity index, and RV/LV ratios). Logistic regression analysis was performed to identify variables that might separate fetuses with TOF from normal controls. RESULTS: The mean gestational age at the time of the last examination prior to delivery was 28 weeks 5 days (SD 4 weeks, 4 days). The mean z-scores were significantly lower in fetuses with TOF for the 4CV and RV and LV measurements of size and shape. Logistic regression analysis identified simple linear measurements of the 4CV, RV, and LV that had a sensitivity of 90.9 and specificity of 98.5% that outperformed the 4CV cardiac axis (sensitivity of 22.7%) as a screening tool for TOF. CONCLUSIONS: Measurements of the 4CV, RV, and LV can be used as an adjunct to the outflow tract screening examination to identify fetuses with TOF.


Asunto(s)
Tetralogía de Fallot , Femenino , Feto , Edad Gestacional , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Embarazo , Estudios Retrospectivos , Tetralogía de Fallot/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA