Int J Lab Hematol ; 42(5): 650-660, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32426926

RESUMEN

INTRODUCTION: We aimed at evaluating the performance of a new prothrombin time (PT) reagent (STA-NeoPTimal) with two other PT reagents (STA-Neoplastine R and STA-Neoplastine CI Plus) and the reference PT reagent used in our laboratory (ReadiPlasTin). METHODS: Evaluation consisted in intra- and interassay precision assessment, determination of sensitivity to unfractionated heparin (UFH) or enoxaparin in spiked samples and to direct oral anticoagulants (DOACs) in patients (n = 43). Method comparison of the 4 PT reagents, factor II, V, VII and X assays was tested on normal (n = 20) and abnormal samples: VKA (n = 47), preoperative (n = 23), liver failure (n = 12) and burned patients (n = 37). RESULTS: Analytical performance met manufacturers' criteria for all reagents. All PT reagents gave correlation coefficients >0.8 and even >0.9 in many situations. In some VKA samples, differences ≥ 0.5 INR units were found in samples within and above therapeutic ranges. For burned patients, PT correlations were good but with some minimal bias (<5.0%) while factor assays gave very consistent results (R > .8 and mainly >0.9). As expected, poor responsiveness of the PT to DOAC concentrations was observed with all four assays. CONCLUSION: The STA-NeoPTimal showed comparable performance to ReadiPlasTin, making it suitable for VKA control, detection of factors II, V, VII, X deficiency and assessment of liver disease coagulopathy. However, for patients receiving VKA, some significant differences were observed. We confirmed the inability of the PT assay to detect residual DOAC concentrations. Finally, burned patients results showed that recombinant thromboplastins were less sensitive to factor deficiencies in comparison to extraction thromboplastins.


Asunto(s)
Relación Normalizada Internacional/instrumentación , Relación Normalizada Internacional/métodos , Tiempo de Protrombina/instrumentación , Tiempo de Protrombina/métodos , Tromboplastina , Coagulación Sanguínea/efectos de los fármacos , Pruebas de Coagulación Sanguínea/instrumentación , Pruebas de Coagulación Sanguínea/métodos , Pruebas de Coagulación Sanguínea/normas , Humanos , Relación Normalizada Internacional/normas , Fallo Hepático/sangre , Fallo Hepático/diagnóstico , Periodo Preoperatorio , Tiempo de Protrombina/normas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Vitamina K/administración & dosificación
2.
J Thromb Haemost ; 17(8): 1273-1287, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31063645

RESUMEN

BACKGROUND: Thrombin generation testing has been used to provide information on the coagulation phenotype of patients. The most used technique is the calibrated automated thrombogram (CAT) but it suffers from a lack of standardization, preventing its implementation in routine. The ST Genesia is a new analyzer designed to assess thrombin generation based on the same principle as the CAT. Unlike the CAT system, the ST Genesia is a benchtop, fully automated analyzer, able to perform the analyses individually and not by batch, with strict control of variables such as temperature and volumes, ensuring, theoretically, maximal reproducibility. OBJECTIVES: This study aimed at assessing the performance of the STG-DrugScreen application on the ST Genesia analyzer. We also aimed at exploring stability of plasma samples after freezing and defining a reference normal range. RESULTS: Results demonstrated the excellent interexperiment precision of the ST Genesia and confirmed that the use of a reference plasma helps reducing the inter-experiments variability. Stability revealed that plasma samples are stable for at least 11 months at -70°C or lower, except for those containing low molecular weight heparins which have to be tested within 6 months. Freezing had no effect on the majority of thrombin generation parameters except on time to peak. CONCLUSIONS: Our results suggest an easy implementation of thrombin generation with the use of ST Genesia in the routine laboratory. This will facilitate the design of multicentric studies and enable the establishment of reliable and evidence-based thresholds, which may improve the management of patients treated with anticoagulants.


Asunto(s)
Pruebas de Coagulación Sanguínea/normas , Coagulación Sanguínea , Trombina/metabolismo , Adolescente , Adulto , Anticoagulantes/administración & dosificación , Automatización de Laboratorios , Biomarcadores/sangre , Coagulación Sanguínea/efectos de los fármacos , Recolección de Muestras de Sangre/normas , Calibración , Femenino , Congelación , Humanos , Masculino , Valor Predictivo de las Pruebas , Estabilidad Proteica , Control de Calidad , Valores de Referencia , Reproducibilidad de los Resultados , Adulto Joven