Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Catheter Cardiovasc Interv ; 97(5): E743-E747, 2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-32790085

RESUMEN

In the era of transcatheter aortic valve replacement (TAVR), the spectrum of indications for balloon aortic valvuloplasty is growing, especially in old and frail patients. Mini-invasive approaches via radial access reduce vascular complications and length of hospital stay. The snuffbox approach has never been described for Balloon aortic valvuloplasty (BAV). We performed a review of patients who underwent BAV using distal radial access between January 2019 and December 2019 in a single Italian Centre. All patients received a 30-day follow-up. The procedure was successfully conducted by anatomical snuffbox in all reported cases. All patients were mobilized within 10 h from the procedure without vascular access-related complications. Thirty-day color Doppler ultrasound showed distal radial artery patency in 89% of cases. In our case series, the snuffbox approach for balloon aortic valvuloplasty appeared to be safe and feasible. This approach could be a valid alternative especially in old and frail adults waiting for TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Valvuloplastia con Balón , Reemplazo de la Válvula Aórtica Transcatéter , Adulto , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Valvuloplastia con Balón/efectos adversos , Humanos , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
2.
Radiol Med ; 126(2): 231-242, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32676875

RESUMEN

The prevalence of heart failure (HF) is approximately 1-2% of the adult population in developed countries, rising to ≥ 10% among people over 70. The common symptoms of HF include shortness of breath, ankle swelling and fatigue, determined by a reduced cardiac output. Multimodality imaging is crucial to define HF etiology, determine prognosis and guiding tailored treatments. Echocardiography is the most widely used imaging modality and maintains a pivotal role in the initial diagnostic work-up and in the follow-up of HF patients. Cardiac magnetic resonance (CMR) may support the morpho-functional assessment provided by echocardiography when the acoustic window is limited or a gold standard evaluation is required. Furthermore, CMR is frequently used due to the unmatched capability to characterize myocardial structure. Coronary computed tomography angiography has become the non-invasive imaging of choice to diagnose or rule-out coronary artery disease, acquiring remarkable importance in the management of HF patients. Moreover, emerging capabilities of CT-based tissue characterization may be useful, especially when CMR is contraindicated. Finally, chest CT may contribute to precisely define the framework of HF patients, revealing new insight about cardiopulmonary pathophysiological interactions with potential high prognostic value.


Asunto(s)
Insuficiencia Cardíaca/diagnóstico por imagen , Imagen Multimodal , Enfermedad Crónica , Humanos , Pronóstico
3.
Radiol Med ; 125(11): 1087-1101, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32978708

RESUMEN

Over the past few years, the approach to the 'arrhythmic patient' has profoundly changed. An early clinical presentation of arrhythmia is often accompanied by non-specific symptoms and followed by inconclusive electrocardiographic findings. In this scenario, cardiac magnetic resonance (CMR) has been established as a clinical tool of fundamental importance for a correct prognostic stratification of the arrhythmic patient. This technique provides a high-spatial-resolution tomographic evaluation of the heart, which allows studying accurately the ventricular volumes, identifying even segmental kinetic anomalies and properly detecting diffuse or focal tissue alterations through an excellent tissue characterization, while depicting different patterns of fibrosis distribution, myocardial edema or fatty substitution. Through these capabilities, CMR has a pivotal role for the adequate management of the arrhythmic patient, allowing the identification of those phenotypic manifestations characteristic of structural heart diseases. Therefore, CMR provides valuable information to reclassify the patient within the wide spectrum of potentially arrhythmogenic heart diseases, the definition of which remains the major determinants for both an adequate treatment and a poor prognosis. The purpose of this review study was to focus on the role of CMR in the evaluation of the main cardiac clinical entities associated with arrhythmogenic phenomena and to present a brief debate on the main pathophysiological mechanisms involved in the arrhythmogenesis process.


Asunto(s)
Arritmias Cardíacas/diagnóstico por imagen , Técnicas de Imagen Cardíaca/métodos , Cardiomiopatías/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Arritmias Cardíacas/etiología , Arritmias Cardíacas/fisiopatología , Cardiomegalia Inducida por el Ejercicio , Cardiomiopatías/complicaciones , Cardiomiopatías/fisiopatología , Diagnóstico Diferencial , Ecocardiografía/métodos , Electrocardiografía , Fibrosis Endomiocárdica/complicaciones , Fibrosis Endomiocárdica/diagnóstico por imagen , Humanos , Prolapso de la Válvula Mitral/complicaciones , Prolapso de la Válvula Mitral/diagnóstico por imagen
4.
Eur Heart J Suppl ; 21(Suppl C): C17-C20, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30996702

RESUMEN

The association of chronic obstructive pulmonary disease (COPD) and ischaemic heart disease (IHD) is challenging both in terms of prognosis and of pharmacological treatment. An 83-year-old Caucasian male patient has chronic kidney disease, COPD, previous myocardial infarction, coronary artery bypass graft with left internal mammary artery (LIMA) on left anterior descending (LAD), saphenous vein graft (SVG) on obtuse marginal (OM)1 and on right coronary artery, and percutaneous coronary intervention (PCI) on LAD (occlusion of LIMA) and on SVG for OM1 (SVG critical stenosis). Recently, the patient complained worsening angina [Canadian Cardiovascular Society (CCS) III] and had residual ischaemia in the anterior wall after an unsuccessful attempt of PCI was performed on LAD for in-stent occlusion due to restenosis. Bisoprolol uptitration failed due to worsening of pulmonary function at spirometry. For this reason, ivabradine 5 mg b.i.d. was added to bisoprolol. Afterwards, the patient referred amelioration of symptoms and he is actually in CCS Class I. The control spirometry showed moderate obstruction comparable to his chronic situation. Patients with IHD and COPD often do not receive ß-blockers due to the fear of adverse effects. However, cardioselective ß-blockers do not worsen pulmonary function while they reduce mortality in COPD patients. In this setting, ivabradine could be extremely helpful in order to control symptoms since it is effective in patients with asthma and COPD, with no alteration in respiratory function or symptoms and improves exercise capacity and functional class in COPD patients.

5.
JAMA Cardiol ; 8(7): 662-673, 2023 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-37285143

RESUMEN

Importance: The clinical utility of stress cardiovascular magnetic resonance imaging (CMR) in stable chest pain is still debated, and the low-risk period for adverse cardiovascular (CV) events after a negative test result is unknown. Objective: To provide contemporary quantitative data synthesis of the diagnostic accuracy and prognostic value of stress CMR in stable chest pain. Data Sources: PubMed and Embase databases, the Cochrane Database of Systematic Reviews, PROSPERO, and the ClinicalTrials.gov registry were searched for potentially relevant articles from January 1, 2000, through December 31, 2021. Study Selection: Selected studies evaluated CMR and reported estimates of diagnostic accuracy and/or raw data of adverse CV events for participants with either positive or negative stress CMR results. Prespecified combinations of keywords related to the diagnostic accuracy and prognostic value of stress CMR were used. A total of 3144 records were evaluated for title and abstract; of those, 235 articles were included in the full-text assessment of eligibility. After exclusions, 64 studies (74 470 total patients) published from October 29, 2002, through October 19, 2021, were included. Data Extraction and Synthesis: This systematic review and meta-analysis adhered to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses. Main Outcomes and Measures: Diagnostic odds ratios (DORs), sensitivity, specificity, area under the receiver operating characteristic curve (AUROC), odds ratio (OR), and annualized event rate (AER) for all-cause death, CV death, and major adverse cardiovascular events (MACEs) defined as the composite of myocardial infarction and CV death. Results: A total of 33 diagnostic studies pooling 7814 individuals and 31 prognostic studies pooling 67 080 individuals (mean [SD] follow-up, 3.5 [2.1] years; range, 0.9-8.8 years; 381 357 person-years) were identified. Stress CMR yielded a DOR of 26.4 (95% CI, 10.6-65.9), a sensitivity of 81% (95% CI, 68%-89%), a specificity of 86% (95% CI, 75%-93%), and an AUROC of 0.84 (95% CI, 0.77-0.89) for the detection of functionally obstructive coronary artery disease. In the subgroup analysis, stress CMR yielded higher diagnostic accuracy in the setting of suspected coronary artery disease (DOR, 53.4; 95% CI, 27.7-103.0) or when using 3-T imaging (DOR, 33.2; 95% CI, 19.9-55.4). The presence of stress-inducible ischemia was associated with higher all-cause mortality (OR, 1.97; 95% CI, 1.69-2.31), CV mortality (OR, 6.40; 95% CI, 4.48-9.14), and MACEs (OR, 5.33; 95% CI, 4.04-7.04). The presence of late gadolinium enhancement (LGE) was associated with higher all-cause mortality (OR, 2.22; 95% CI, 1.99-2.47), CV mortality (OR, 6.03; 95% CI, 2.76-13.13), and increased risk of MACEs (OR, 5.42; 95% CI, 3.42-8.60). After a negative test result, pooled AERs for CV death were less than 1.0%. Conclusion and Relevance: In this study, stress CMR yielded high diagnostic accuracy and delivered robust prognostication, particularly when 3-T scanners were used. While inducible myocardial ischemia and LGE were associated with higher mortality and risk of MACEs, normal stress CMR results were associated with a lower risk of MACEs for at least 3.5 years.


Asunto(s)
Enfermedad de la Arteria Coronaria , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/complicaciones , Medios de Contraste , Pronóstico , Imagen por Resonancia Cinemagnética/métodos , Gadolinio , Imagen por Resonancia Magnética/métodos , Dolor en el Pecho , Arterias
6.
Diagnostics (Basel) ; 12(4)2022 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-35453834

RESUMEN

(1) Background: The impact of imaging-derived ischemia is still under debate and the role of stress perfusion cardiac magnetic resonance (spCMR) in non-high-risk patient still needs to be clarified. The aim of this study was to evaluate the impact of spCMR in a case series of stable long-standing chronic coronary syndrome (CCS) patients with ischemia and no other risk factor. (2) Methods: This is a historical prospective study including 35 patients with history of long-standing CCS who underwent coronary CT angiography (CCTA) and additional adenosine spCMR. Clinical and imaging findings were included in the analysis. Primary outcomes were HF (heart failure) and all major cardiac events (MACE) including death from cardiovascular causes, myocardial infarction, or hospitalization for unstable angina, or resuscitated cardiac arrest. (3) Results: Mean follow-up was 3.7 years (IQR: from 1 to 6). Mean ejection fraction was 61 ± 8%. Twelve patients (31%) referred primary outcomes. Probability of experiencing primary outcomes based on symptoms was 62% and increased to 67% and 91% when multivessel disease and ischemia, respectively, were considered. Higher ischemic burden was predictive of disease progression (OR: 1.59, 95%CI: 1.18-2.14; p-value = 0.002). spCMR model resulted non inferior to the model comprising all variables (4) Conclusions: In vivo spCMR-modeling including perfusion and strain anomalies could represent a powerful tool in long-standing CCS, even when conventional imaging predictors are missing.

7.
Sci Rep ; 12(1): 5125, 2022 03 24.
Artículo en Inglés | MEDLINE | ID: mdl-35332224

RESUMEN

Systemic sclerosis (SSc) is an uncommon autoimmune disease. Aim of the study was to detect the occult cardiac involvement in asymptomatic SSc patients of recent onset (indicative of a more aggressive disease) with unenhanced Cardiac Magnetic Resonance (CMR). Our historical prospective study included naïve SSc patients of recent onset. Modified Rodnan Skin Score (mRSS) and Scleroderma Clinical Trial Consortium Damage Index (SCTC-DI) were calculated. Cardiac volumes and global myocardial strain were assessed and also compared with healthy group values. Pericardial involvement was further recorded. Thirty-one patients met inclusion criteria (54 ± 12 years; 1 M). Mean duration of disease was 6.8 years. All patients showed preserved systolic function. Higher incidence of pericardial involvement was founded in patients with disease accrual damage (OR: 9.6, p-value 0.01). Radial and longitudinal strain values resulted significantly different between healthy and SSc patients. GRS and GLS showed an independent predictive validity on damage accrual (HR: 1.22 and 1.47, respectively). Best C-index for disease progression was reached when strain values and pericardial evaluation were added to conventional risk factors (0.97, p-value: 0.0001). Strain analysis by CMR-TT may show a high capability both in identifying early cardiac involvement and stratifying its clinical aggressiveness, regardless of the standard damage indices and CMR contrast-dependent biomarker.


Asunto(s)
Imagen por Resonancia Magnética , Esclerodermia Sistémica , Corazón/diagnóstico por imagen , Humanos , Espectroscopía de Resonancia Magnética , Estudios Prospectivos , Esclerodermia Sistémica/complicaciones , Esclerodermia Sistémica/diagnóstico por imagen
8.
Diagnostics (Basel) ; 12(10)2022 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-36291987

RESUMEN

Since 1997, heart failure (HF) has been designated as a new epidemic. However, it is not easy to find a proper definition since different descriptors are used in clinical practice. Moreover, HF is not a single clinical entity, and there is a close relationship between HF and all cardiomyopathies (CMs). This leads us to also consider accuracy in the characterization of CMs, which is essential to define the therapeutic process of HF patients. This narrative review aims to describe the main mechanisms leading to HF in different CMs, as well as the current diagnostic and prognostic advantages deriving from advanced imaging in the cardiac field.

9.
Heart ; 107(11): 874-880, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33627400

RESUMEN

OBJECTIVE: The study was designed to: (1) confirm safety and feasibility of mini-invasive radial balloon aortic valvuloplasty (BAV); (2) assess its impact in terms of quality of life and frailty; and (3) evaluate whether changes in frailty after BAV are associated with death in patients undergoing transcatheter aortic valve implantation (TAVI). METHODS: 330 patients undergoing BAV in 16 Italian centres were prospectively included. The primary endpoint was the occurrence of major and minor Valve Academic Research Consortium (VARC)-2 bleeding. Secondary endpoints were scales of quality of life, frailty, evaluated at baseline and 30 days, and their relationship with the occurrence of all-cause death. RESULTS: BAV was performed by radial access in 314 (95%) patients. No VARC-2 major and six (1.8%) VARC-2 minor bleedings occurred in the study population. Quality of life, as well as frailty status, significantly improved 30 days after BAV. At 1 year, patients undergoing TAVI with baseline essential frailty toolset (EFT) <3 or achieving an EFT <3 after BAV had a comparable occurrence of all-cause death (15% vs 19%, p=0.58). On the contrary, patients with EFT ≥3 at 30 days despite BAV showed the worst prognosis (all-cause death: 40% vs 15% and 19%, p=0.006 and p=0.05, respectively). CONCLUSIONS: Mini-invasive radial BAV is safe, feasible and associated with a low rate of vascular complications. Patients improving EFT 30 days after BAV showed a favourable outcome after TAVI. TRIAL REGISTRATION NUMBER: NCT03087552.


Asunto(s)
Valvuloplastia con Balón , Fragilidad , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/terapia , Estudios de Factibilidad , Femenino , Humanos , Masculino , Mortalidad , Pronóstico , Estudios Prospectivos , Calidad de Vida , Arteria Radial
10.
J Clin Imaging Sci ; 8: 52, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30546936

RESUMEN

PURPOSE: The aim of this study was to compare image quality and mean radiation dose between two groups of patients undergoing coronary computed tomography angiography (CCTA) using a 640-slice CT scanner with two protocols with different noise level thresholds expressed as standard deviation (SD). MATERIALS AND METHODS: Two-hundred and sixty-eight patients underwent a CCTA with 640 slice CT scanner. In the experimental group (135 patients), an SD 51 protocol was employed; in the control group (133 patients), an SD 33 protocol was used. Mean effective dose and image quality with both objective and subjective measures were assessed. Image quality was subjectively assessed using a five-point scoring system. Segments scoring 2, 3, and 4 were considered having diagnostic quality, while segments scoring 0 and 1 were considered having nondiagnostic quality. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) between the two groups as well as the effective radiation dose (ED) was finally assessed. RESULTS: Comparative analysis considering diagnostic quality (2, 3, and 4 score) and nondiagnostic (score 0 and 1) quality demonstrated that image quality of SD 51 group is not significantly lower than that of S33 group. The noise was significantly higher in the SD 51 group than in the SD 33 group (P < 0.0001). The SNR and CNR were higher in the SD 33 group than in SD 51 group (P < 0.0001). Mean effective dose was 49% lower in the SD 51 group than in SD 33 group; indeed mean effective dose was 1.43 mSv ± 0.67 in the SD 51 group while it was 2.8 mSv ± 0.57 in the SD 33 group. CONCLUSION: Comparative analysis shows that using a 640-slice CT with a 51 SD protocol, it is possible to reduce the mean radiation dose while maintaining good diagnostic image quality.

11.
Open Med (Wars) ; 11(1): 143-151, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-28352783

RESUMEN

At present time, both CT and MRI are valuable techniques in the study of the thoracic aorta. Nowadays, CT represents the most widely employed technique for the study of the thoracic aorta. The new generation CTs show sensitivities up to 100% and specificities of 98-99%. Sixteen and wider row detectors provide isotropic pixels, mandatory for the ineludible longitudinal reconstruction. The main limits are related to the X-ray dose expoure and the use of iodinated contrast media. MRI has great potential in the study of the thoracic aorta. Nevertheless, if compared to CT, acquisition times remain longer and movement artifact susceptibility higher. The main MRI disadvantages are claustrophobia, presence of ferromagnetic implants, pacemakers, longer acquisition times with respect to CT, inability to use contrast media in cases of renal insufficiency, lower spatial resolution and less availability than CT. CT is preferred in the acute aortic disease. Nevertheless, since it requires iodinated contrast media and X-ray exposure, it may be adequately replaced by MRI in the follow up of aortic diseases. The main limitation of MRI, however, is related to the scarce visibility of stents and calcifications.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA