Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Clin Oral Implants Res ; 33(1): 94-104, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34624157

RESUMEN

OBJECTIVES: To compare gingival tissue healing at surgically manipulated periodontal sites and at sites receiving implants and healing abutments with machined (MS) vs laser-microtextured (LMS) surface placed with one-stage protocol. MATERIAL AND METHODS: Twenty-four non-smoking patients each received two implants with one-stage protocol in a split-mouth design on the same jaw. In each patient, one implant with a MS collar and one immediate healing abutment with a MS, and one implant with a LMS collar and one immediate healing abutment with a LMS were used. Soft tissues healing at surgically manipulated periodontal tissues (T+) and at non-surgically manipulated periodontal tissues (T-) at MS implant sites and at LMS implant sites were compared by means of clinical and biochemical parameters at baseline and at 1-2-3-4-6-8 and 12 weeks. RESULTS: PD and BoP mean values were statistically higher in MS than LMS implant sites (p<0.05). During early healing phase (1-4 weeks), MS and LMS peri-implant tissues and periodontal tissues at T(+) showed no statistically significant difference in crevicular fluid volume changes (p>0.05). Between 6 and 12 weeks, compared with T(+), no statistically significant difference in crevicular fluid volume and IL-6 and IL-1ß concentrations was noted in LMS implant sites (p>0.05), while statistically significantly higher mean values were noted in MS implant sites (p<0.05). CONCLUSIONS: Compared with T(+) and T(-), both MS and LMS implant sites presented a higher pro-inflammatory state in the early phase after surgery (1-4 weeks). At 12 weeks, only MS implant sites kept a higher pro-inflammatory state, while at LMS implant sites, it becomes similar to T(+) and T(-).


Asunto(s)
Implantes Dentales , Interleucina-6 , Biometría , Humanos , Rayos Láser , Boca
2.
Clin Oral Implants Res ; 32(4): 422-436, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33452830

RESUMEN

OBJECTIVES: To retrospectively evaluate the conditions of the peri-implant tissues in treated patients with chronic periodontitis (CP) and in patients without chronic periodontitis (noCP). MATERIALS AND METHODS: A chart review was used to evaluate 267 implants, 134 placed in 42 CP treated patients and 133 placed in 46 noCP patients. The primary outcome was to evaluate the condition of the peri-implant tissues (health, peri-mucositis, and peri-implantitis). The secondary outcome was to evaluate the possible association of some variables, such as, Plaque Index (PI), Bleeding Index (BI), probing pocket depth (PD), bleeding on probing (BoP), bone level (BL), loading time, type of implant placement and loading protocol, type of prosthesis, type of bone, implant manufacturer, and implant diameter and length, with the implant health condition. RESULTS: The analysis of patient files revealed that after 10-15 years of loading (mean loading time 13.4 ± 2.07 years), six noCP patients (13%) experienced implant loss with a total of nine implants (6.7%) lost. The remaining 124 implants were classified: 54 (43.5%) as healthy, 45 (36.3%) with peri-implant mucositis, and 25 (20.2%) with peri-implantitis. Twelve CP subjects (28.5%) experienced implant loss with a total of 19 implants (14.1%) lost. The remaining 115 implants were classified: 34 (29.5%) as healthy, 40 (34.7%) with peri-implant mucositis and 41 (35.6%) with peri-implantitis. Compared with noCP subjects, only treated CP subjects with recurrent periodontal disease (RPD) showed differences statistically significant (p < .05). CONCLUSIONS: After 10-15 years of loading, in CP patients treated in a private practice setting, most implants (70.1%) were classified with some type of peri-implant inflammation. In patients with RPD, a higher tendency for implant loss and peri-implant biologic complications was found.


Asunto(s)
Pérdida de Hueso Alveolar , Periodontitis Crónica , Implantes Dentales , Periimplantitis , Implantes Dentales/efectos adversos , Humanos , Periimplantitis/etiología , Práctica Privada , Estudios Retrospectivos
3.
J Contemp Dent Pract ; 22(4): 427-434, 2021 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-34267014

RESUMEN

AIM: The aim of this systemic review is to investigate these parameters by analyzing the characteristics of fractured instruments to determine which is the most relevant mechanical stress that induces intracanal separation in vivo. BACKGROUND: The fracture of nickel-titanium (Ni-Ti) instruments is a result of flexural fatigue and torsional fatigue. An electronic search was conducted in MEDLINE database, Web of Science, and Cochrane following preferred reporting items for systematic reviews and meta-analyses guidelines. Data were collected and the key features from the included studies were extracted. Overview quality assessment questionnaire scoring assessed the quality of the articles. A total of 12 articles were selected, where the lowest score was 13. REVIEW RESULTS: Considering Ni-Ti rotary instruments, this overall evaluation comprehends 939 broken instruments with an incidence of fracture of 5%. Out of the 12 selected articles, 10 studies revealed that flexural failure was the predominant mode (range of 62-92%). It appears that motion plays an important role when it comes to mechanisms of fracture. The majority of defects found in hand-operated instruments were in the form of torsional failure. Although the major cause of separation of rotary instruments is flexural fatigue, smaller instruments show more torsional fracture than the larger instruments. The average fragment length was found to be 2.5 mm and 3.35 mm, respectively, for torsional failure and flexural failure. The risk of bias depends on fractographic analysis. CONCLUSION: Flexural fatigue is the predominant mode of fracture in rotary Ni-Ti instruments. The type of motion and size of the instrument seem to affect the mechanism of fracture. Fragment length may show a strong association with the type of fracture mechanism. CLINICAL SIGNIFICANCE: This systemic review found that flexural fatigue is the most relevant mechanical stress that induces intracanal separation in vivo. Moreover, in clinical practice, the fragment length might be an excellent indicator of the type of fracture.


Asunto(s)
Níquel , Titanio , Aleaciones Dentales , Instrumentos Dentales , Diseño de Equipo , Falla de Equipo , Incidencia , Preparación del Conducto Radicular , Estrés Mecánico , Torsión Mecánica
4.
J Contemp Dent Pract ; 22(3): 215-218, 2021 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-34210917

RESUMEN

AIM AND OBJECTIVE: The aim and objective of this study was to evaluate and compare the cutting efficacy of two different nickel titanium rotary instruments by a novel methodology: the operative torque (torque and time needed to progress toward the apex). MATERIALS AND METHODS: Ten fresh extracted upper first premolars with two canals were instrumented with a KaVo (Biberach, Germany) and a KaVo 1:1 handpiece at 300 rpm with maximum torque set at 2 N. One canal was instrumented with ProGlider NiTi rotary instruments (Dentsply Sirona Endodontics, Ballaigues, Switzerland), with tip size of 16.02, and the other one with EgdeGlidePath rotary instrument (EdgeEndo, Albuquerque, New Mexico). Mean instrumentation time, mean torque values, and maximum torque values were evaluated for each instrument. The significance level was set at p <0.05. RESULTS: EdgeGlidePath instruments reached the working length in significantly less time with a significantly smaller amount of torque when compared to ProGlider (p >0.05). No instruments exhibited flute deformation or underwent intracanal failure. CONCLUSIONS: Operative torque is related to the capability to cut dentin and progress toward the apex: the smaller the torque values, the higher the cutting ability (and safety). Operative torque is also dependent on debris removal and irrigation techniques. Nevertheless, both operative torque and instrumentation time are clinically relevant parameters for evaluating instruments' performance (i.e., cutting ability). CLINICAL SIGNIFICANCE: Operative torque during endodontic instrumentation helps understanding the overall performance in terms of both cutting efficiency and safety.


Asunto(s)
Níquel , Preparación del Conducto Radicular , Aleaciones , Aleaciones Dentales , Instrumentos Dentales , Cavidad Pulpar , Diseño de Equipo , Alemania , Titanio , Torque
5.
J Contemp Dent Pract ; 21(10): 1073-1074, 2020 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-33686025

RESUMEN

During the long history of their evolution, higher organisms, including mammals, have learnt to take great advantage from living in close contact with selected populations of microbes.1 By living in close contact, animals and microbes underwent a progressive and mutual co-evolutive process that is believed to be a major driving force in the development of adaptive immunity of vertebrates.2.


Asunto(s)
Factores Biológicos , Microbiota , Animales
6.
J Contemp Dent Pract ; 21(6): 598, 2020 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-33025924

RESUMEN

COVID-19 pandemic has strongly and rapidly affected routine lifestyle and consequently, dental business, practice, and education. During the pandemic period, most Governments worldwide made specific regulations or recommendations to close practices, to avoid non-urgent dental therapies and treat only dental emergencies. Some recent surveys1,2 showed how dentists perceived the COVID-19 risk and how they reacted: by modifying their way of working, by reducing aerosol producing procedures, by improving staff and patient's safety with the increased use of personal protective equipment, environmental disinfection and limited access to dental offices, increasing use of remote consulting and triage.


Asunto(s)
Infecciones por Coronavirus , Desinfección , Pandemias , Neumonía Viral , Betacoronavirus , COVID-19 , Humanos , Pandemias/prevención & control , SARS-CoV-2 , Encuestas y Cuestionarios
7.
J Contemp Dent Pract ; 21(2): 113, 2020 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-32381811

RESUMEN

The role of nickel-titanium (NiTi) in the production of endodontic instruments increased in the last few decades; therefore, the way of evaluation of its performance increased as well. Nowadays, there are several ways to evaluate NiTi instruments, divided into static and dynamic tests. The static ones are cyclic fatigue tests, torsional resistance tests, flexibility, and cutting efficiency tests. These methodologies have been deeply used to evaluate some of the metallurgical properties of the instruments on the market. Up-to-date, we know very well the behavior of NiTi under static conditions, but these knowledges are too fragmented to be relevant for understanding and evaluating the complexities of intracanal instrumentation. Starting from the purpose to introduce the variable of movement in the testing procedure, some dynamic tests have been proposed, such as dynamic cyclic fatigue test.1,2 Although these kinds of studies were capable of evaluating more precisely the behavior of rotary instruments inside the root canal, they could not take into account, at this moment, the complexities of stresses that instruments undergo during the shaping procedure.3-5 Therefore, some of these tests are not accepted anymore by the scientific community and on the contrary they do not help the general practitioner to orientate in the large amount of rotary instruments present on the market.6 This tends to withdraw the general dentistry from the scientific literature, wearing a groove between the practice and the science.7 Starting from these ideas, in the last couple of years some authors started to think the proper way to real-time evaluation of the performance of NiTi rotary instruments inside the root canal. To do so, a countable and repeatable measurement of instrument's developed stresses was needed. Setzer and Böhme8 first used the torque generated by Revo-S, Vortex, and ProFile to evaluate their performance during instrumentation. The so-called "operative torque" is the summation of torque generated in each point of the instrument during its simultaneous movement around its own axis and up and down inside the canal. The recorded values are influenced by both torsional and flexural stresses, becoming this way a reliable method to analyze, evaluate, and compare the performance of NiTi instruments inside the root canal.9 This methodology is applicable for not only in vitro but also in vivo measurement, as demonstrated by Gambarini et al.10 The main drawback of this kind of evaluation is the not well-determined correlation between the torsional and the flexural stresses; therefore, it is still unpredictable how each influence the other. In conclusion, the potential of real-time torque measurement is wide and still unexplored, but further studies are needed to better understand how torque is developed inside the root canal.


Asunto(s)
Níquel , Titanio , Aleaciones Dentales , Preparación del Conducto Radicular , Torque
8.
J Contemp Dent Pract ; 21(5): 539-542, 2020 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-32690836

RESUMEN

AIM: The aim of the present study was to investigate the role of the flat design compared with a non-flat designed instrument on the centering ability in a simulated root canal system. MATERIALS AND METHODS: Two file systems were chosen: the F-One (Fanta Dental, Shanghai, China) and a prototype with the same design but without the flat-side design. A total of 50 simulated L-shaped root canals in resin blocks were shaped with a new instrument each. Pre- and postcanal preparation images were captured and superimposed to measure and compare the canal transportation and evaluate the centering ability of each file. The t test was performed and the level of significance was set at p < 0.05. RESULTS: Prototype files removed significantly less resin from the inner and the outer parts of the canal and showed significantly higher mean transportation values. CONCLUSION: It can be concluded that the F-One file system demonstrated better shaping ability compared with the prototype file system in L-shaped resin-simulated canals. CLINICAL RELEVANCE: The present study showed the safety of the flat-side design, minimizing the risk of iatrogenic errors such as ledging, perforation, or zipping of the root canal.


Asunto(s)
Níquel , Titanio , China , Aleaciones Dentales , Instrumentos Dentales , Cavidad Pulpar , Diseño de Equipo , Preparación del Conducto Radicular
9.
J Contemp Dent Pract ; 21(7): 718-722, 2020 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-33020352

RESUMEN

AIM: The present study was conducted to assess the perceived risk of COVID-19 transmission in dental professionals (DPs), that include dentists and dental auxiliary staffs, and whether rapid tests should be a recommended tool to constrain the transmission of the COVID-19, and who should be bearing their cost (governments, dentists, or patients) through an online survey. MATERIALS AND METHODS: A sample size of n = 700 was recruited in the study. The study included DPs from all over the world. A randomized selection of samples was done through dental groups present on social networks. An online survey was conducted in April 2020, using the Google Form software to provide questions and collect and elaborate answers. Data were analyzed using the statistical software STATA and presented in terms of percentages. RESULTS: About 78% of the study participants perceived a very high risk of COVID-19 contamination in dental settings. Nearly 80% of the study participants were willing to be subjected to rapid tests and the same could be performed on patients visiting their dental clinics, which could prevent the spread of the disease. About 55% of the participants had reported that additional costs for the rapid tests should be borne by the governments. CONCLUSION: The results of the present survey report that DPs do not feel safe and perceive a high risk of COVID-19 contagion and prevention of the disease could be done by performing rapid tests on dentists, dental staff, and patients visiting the dental clinics irrespective of age and gender of the participants. SIGNIFICANCE: Since all the dentists and allied staff have perceived increased risk for COVID-19 transmission, it is important that preventive measures are implemented through rapid test kits at the earliest.


Asunto(s)
Técnicas de Laboratorio Clínico , Infecciones por Coronavirus , Odontólogos , Pandemias , Neumonía Viral , Betacoronavirus , COVID-19 , Prueba de COVID-19 , Infecciones por Coronavirus/diagnóstico , Odontología , Humanos , Riesgo , SARS-CoV-2 , Encuestas y Cuestionarios
10.
J Contemp Dent Pract ; 21(11): 1275-1278, 2020 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-33850075

RESUMEN

AIM AND OBJECTIVE: The aim of this case report was to describe regenerative endodontic procedures (REPs) of the previously treated mature teeth with long-term results. BACKGROUND: Regenerative endodontic procedures are aimed to treat apical periodontitis and regenerate the pulp-dentin complex in necrotic teeth. However, there is no consensus in using REPs in the previously treated mature teeth. The aim of this case report was to describe REPs of the previously treated mature teeth with long-term results. CASE DESCRIPTION: A 25-year-old woman presented pain on chewing on 15 and swelling (WHO numbering system). The tooth had been endodontically treated and restored 4 years ago. After removing the old root canal filing, the roots were irrigated with 2.5% sodium hypochlorite and 17% EDTA using sonic activation. Calcium hydroxide (CH) was used as medicament for 3 weeks. At the second visit, CH was removed, and canals were irrigated as like as the first visit. Apical bleeding was induced, and concentrated growth factors (CGFs) were placed inside the root canal. The tooth has been followed up to 3 years. CONCLUSION: The tooth was functional and asymptomatic at the recall visits. Since the first-year follow-up, the tooth responded to the electric pulp test and the thermal test. Radiological examinations revealed healing of apical lesion and hard tissue deposition. CLINICAL SIGNIFICANCE: Regenerative endodontic procedures can offer an advantage over traditional endodontic procedures in terms of tertiary healing, with a predictable, user-friendly procedure also for retreatment cases.


Asunto(s)
Periodontitis Periapical , Endodoncia Regenerativa , Adulto , Necrosis de la Pulpa Dental , Femenino , Humanos , Periodontitis Periapical/diagnóstico por imagen , Periodontitis Periapical/terapia , Retratamiento , Tratamiento del Conducto Radicular
11.
J Contemp Dent Pract ; 21(4): 404-409, 2020 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-32584277

RESUMEN

AIM: The aim of this study was to analyze, by the aid of microbiological analysis and the field emission scanning electron microscopical (FE-SEM) analysis, the role of high-density polytetrafluoroethylene (d-PTFE) membranes in avoiding the microbial colonization of a nanocrystalline hydroxyapatite (nc-HA) bone graft and the involvement of this colonization in the healing process. MATERIALS AND METHODS: Six patients underwent extraction of unrecoverable teeth, and a socket preservation technique was carried out with nc-HA synthetic bone graft and then covered with a d-PTFE membrane. After 28 days from surgery, FE-SEM analysis and BioTimer assay technique to assess the microbiological count of streptococci species were carried out. Data were collected and analyzed by the Student's t test (confidence interval: 95%). RESULTS: The mean amount of bacteria measured on the upper side of the membrane was 6.52 ± 0.50 CFU, while on the lower side, it was 6.59 ± 0.40 CFU. Significant differences were not found between the two sides of the membrane or between the different sectors (p > 0.05). The FE-SEM analysis revealed structured biofilms on both sides of the membrane: species of cocci, bacilli, and fusobacteria were recognizable in occasional settled vegetations. CONCLUSION: Since the amount of bacteria found was low, the improved impermeability of the d-PTFE membrane permitted the healing process to proceed uneventful and without signs of infection or inflammation. CLINICAL RELEVANCE: The infection of the graft site could lead to a failure of the socket preservation technique which could delay or compromise the rehabilitation following procedures. The use of d-PTFE can improve the bone regeneration thanks to its antimicrobial properties.


Asunto(s)
Pérdida de Hueso Alveolar , Aumento de la Cresta Alveolar , Durapatita , Humanos , Membranas Artificiales , Microscopía Electrónica de Rastreo , Politetrafluoroetileno , Extracción Dental , Alveolo Dental/cirugía
12.
J Contemp Dent Pract ; 21(6): 599-603, 2020 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-33025925

RESUMEN

AIM: The aim of the present study was to take a survey on Italian practitioners concerning the perceived risks of aerosol contamination in COVID-19 times and their attitude toward modifications of treatment protocols to reduce this risk. MATERIALS AND METHODS: Power analysis calculated a minimum sample size of 150 participants at 99% confidence level with a 5% margin of error. To homogenize responses elicited by different preventive measures by various national governments, only Italian dentists were included in the survey: overall 500 responses were collected. RESULTS: Of the 500 analyzed respondents, there were 266 females and 234 males; 379 practitioners were allocated in the more experienced groups, and the remaining 121 in the less experienced group based on less or more than 5 years of practice. The 70% of the dentists consider the dental practice more dangerous for the diffusion of COVID-19 than other social activities. The 5% consider dental practice more dangerous only for the patients. Aerosol contamination was perceived as a risk from the most dentist (70%), but there was agreement on the most dangerous way of cross infection in dental settings. Most of the dentists (55%) believed implementations in their protocols were needed to reduce the risk of COVID-19 infections. No significant differences were found within the groups: both women and men, as well as practitioners with different experience levels (younger or older than 35 years) perceived very similarly the problems related to COVID-19 in dentistry (p > 0.05). CONCLUSION: The survey demonstrated that COVID-19 had a great impact on dental practitioners; it increased not only fear of aerosol contamination during dental treatments but also influenced the fear of close contacts. SIGNIFICANCE: Airborne and waterborne infections are related with dental treatments and considered the preferred ways of diffusion for COVID-19. The risk of aerosol-related infections could interfere with the clinical practice of the dentist, during the COVID-19 pandemic; the limitations that provided changes to everyday behavior could affect the perception of the safety of the operators, staff, and patient and this could also affect economically the dental office.


Asunto(s)
Infecciones por Coronavirus , Odontólogos , Pandemias , Neumonía Viral , Aerosoles , Betacoronavirus , COVID-19 , Femenino , Humanos , Italia , Masculino , Rol Profesional , SARS-CoV-2 , Encuestas y Cuestionarios
13.
J Contemp Dent Pract ; 21(11): 1284-1292, 2020 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-33850077

RESUMEN

AIM AND OBJECTIVE: The aim of the present case report is to describe the digital management of an implant prosthetic rehabilitation performed by the use of different digital technologies, which allowed to successfully perform in 1 day both the surgical and the prosthetical stages with a minimally invasive approach and a high standard of care. BACKGROUND: Coronavirus disease-2019 (COVID-19) pandemic is affecting dental everyday practice. Clinicians have to reduce the number of patients per day and the time they spend in the dental office. Minimally invasive and digital approaches, with less possible exposure and interaction, are suggested to reduce the risk of infection. CASE DESCRIPTION: The failure of a short-span implant prosthetic rehabilitation combined with pain and mobility of the involved teeth was the main complaint reported by a 78-year-old male patient, who asked an urgent appointment to solve the problem. An intraoral scanner allowed the clinician to immediately take a preliminary digital impression of the arch to be treated. The resulting 3D files were sent by e-mail to the dental technician who provided a digital wax-up for the computerized workflow. Computer-aided implantology (CAI) performed using an in-office cone-beam computed tomography (CBCT) allowed clinician to guide the surgical approach in a prosthetic manner. Such an integration inside a well-defined workflow was the key for a successful and rapid treatment. CONCLUSION: By using new innovative digital technology, the treatment was completed in 1 day, reducing the risk of COVID-19 by limiting the number of appointments and reducing contacts in confined environments like the dental office and public transportations. It also helped to reduce materials production and people movement in the treatment of dental emergency. CLINICAL SIGNIFICANCE: The possibility of performing an effective treatment saving time by using efficient technology and a minimally invasive procedure highlights the importance of digital planning in order to optimize every single step of the treatment. Digital workflow reduces also the movement of potentially infected materials from the office to the dental laboratory.


Asunto(s)
COVID-19 , Diseño Asistido por Computadora , Anciano , Tomografía Computarizada de Haz Cónico , Odontología , Humanos , Masculino , SARS-CoV-2
14.
J Prosthodont ; 28(2): e771-e779, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30168651

RESUMEN

PURPOSE: The aim of this study was to compare survival rates, marginal bone loss (MBL), and peri-implant soft tissue parameters between short and standard laser-microgrooved implants supporting single or splinted crowns 3 years after loading. MATERIALS AND METHODS: 30 subjects received 1 short ( ≤ 7 mm ) and 1 standard length ( ≥ 9 mm ) laser-microgrooved implant in adjacent sites of the premolar and molar regions of the mandible or maxilla. Peri-implant soft tissue parameters and intraoral radiographs were recorded at the delivery of definitive crowns (baseline) and 3 years later. Cumulative survival rate (CSR) and marginal bone loss (MBL) in relation to crown/implant (C/I) ratio, implant length, location, type of antagonist, and type of prosthetic design (single or splinted), were evaluated. RESULTS: CSR of short implants was 98%, compared to 100% for standard implants, without significant statistical difference. MBL was not significantly different over the observation period, with an average of 0.23 ± 0.6 mm and 0.27 ± 0.3 mm for short and standard implants, respectively. No statistical differences were found between short and standard implants regarding plaque (14.7% vs. 15.7%), number of sites BOP (8.3% vs. 5.9%), probing depth (1.13 ± 0.6 mm vs. 1.04 ± 0.8 mm), and mean mucosal recession (0.18 ± 0.3 mm vs. 0.22 ± 0.3 mm). Analyzing MBL in relation to the C/I ratio, implant length, location, type of antagonist, and type of prosthetic design, no statistically significant differences were found. CONCLUSION: Regardless of C/I ratio, implant length, location, type of antagonist, and type of prosthetic design, short and standard laser-microgrooved implants had similar survival rates, MBL, and peri-implant soft tissue conditions over the observation period of 3 years.


Asunto(s)
Coronas , Diseño de Prótesis Dental/métodos , Prótesis Dental de Soporte Implantado , Adulto , Anciano , Anciano de 80 o más Años , Pérdida de Hueso Alveolar/epidemiología , Pérdida de Hueso Alveolar/etiología , Implantes Dentales , Retención de Prótesis Dentales/métodos , Prótesis Dental de Soporte Implantado/métodos , Fracaso de la Restauración Dental , Femenino , Estudios de Seguimiento , Humanos , Rayos Láser , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Radiografía Dental , Adulto Joven
15.
J Pers Med ; 14(4)2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38672969

RESUMEN

The aim of the current study was to retrospectively investigate the prevalence of peri-implant mucositis (PIM) and peri-implantitis (P) in a long-term follow-up (≥20 years) of implants with the same body design and body surface but different collar surfaces with laser-microtextured grooves (LMGSs) vs. no laser-microtextured grooves (no-LMGSs) in private practice patients. Furthermore, several patient-related, implant-related, site-, surgical-, and prosthesis-related potential disease risk factors were analyzed. A chart review of patients receiving at least one pair of implants (one with an LMGS and the other without LMGS) in the period 1993-2002 was used. Chi-square analysis was used to determine if a statistically significant difference between the investigated variables and PIM/P was present. Possible risk factors were statistically evaluated by a binary logistic regression analysis. A total of 362 patients with 901 implant-supported restorations (438 with LMGS and 463 no-LMGS) were included in the study. The cumulative survival rates of implants at 5, 10, 15, and 20 years were 98.1%, 97.4%, 95.4%, and 89.8%, respectively, for the LMGS group, and 93.2%, 91.6%, 89.5%, and 78.3% for the no-LMGS group. The difference was statistically significant at all timepoints (p < 0.05). In total, at the end of the follow-up period, 45.7% of patients and 39.8% of implants presented PIM, and 15.6% of patients and 14% of implants presented P. A total of 164 LMGS implants (37.4%) and 195 no-LMGS implants (42.1%) presented peri-implant mucositis, while 28 (6.3%) of LMGS implants and 98 (21.1%) no-LMGS implants demonstrated peri-implantitis. Differences between LMGS implants and no-LMGS implants were statistically significant (p < 0.05). The binary logistic regression identified collar surface, cigarette smoking, histories of treated periodontitis, and lack of peri-implant maintenance as risk factors for P. After at least 20 years of function in patients followed privately, LMGS implants compared to no-LMGS implants presented a statistically and significantly lower incidence of P. Implant collar surface, cigarette smoking, previously treated periodontitis, and lack of peri-implant maintenance are factors with significant association to P.

16.
Int J Periodontics Restorative Dent ; (7): s118-s128, 2023 Oct 24.
Artículo en Inglés | MEDLINE | ID: mdl-37552172

RESUMEN

This retrospective clinical study compared two different professional maintenance therapy (MT) approaches (with and without periodic removal and decontamination of prosthetic components) on peri-implant inflammatory clinical and biochemical parameters after 5 years of implant function. A retrospective analysis based on patient records was used to assess inflammatory clinical and biochemical parameters around dental implants placed by the same clinician in a private practice. The Plaque Index (PI), peri-implant probing depth (PPD), mucosal recession (REC), bleeding on probing (BOP), and radiographic marginal bone level were determined at baseline and at each follow-up year. Moreover, at the last follow-up visit, the peri-implant intrasulcular levels of active metalloproteinasis 8 (aMMP-8) were also assessed. All participants were under MT with a 6-month recall interval. A total of 92 patients with 132 implants were selected. At the end of the study period, 12 patients with 12 implants were classified as dropouts. The remaining 80 patients and 120 implants were classified into two groups: Group 1 (42 patients, 62 implants) received MT with periodic removal and decontamination of prosthetic components; Group 2 (38 patients, 58 implants) received MT without periodic removal and decontamination of prosthetic components. No statistical differences were found between the groups regarding PI, PPD, and REC. Group 1 presented a statistically significant higher number of sites with BOP (12.4% vs 6.2%). Marginal bone loss was statistically higher in Group 2 than in Group 1 (0.23 ± 0.6 mm vs 0.78 ± 0.3 mm). Intrasulcular levels of aMMP-8 were statistically higher in Group 1 than in Group 2. The supplemental application of periodic removal and decontamination of prosthetic components during MT had a significantly positive effect on the inflammatory status of peri-implant tissues.


Asunto(s)
Implantes Dentales , Humanos , Estudios Retrospectivos , Descontaminación , Índice de Placa Dental
17.
J Imaging ; 10(1)2023 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-38248994

RESUMEN

(1) The possibility of knowing information about the anatomy in advance, in particular the arrangement of the endodontic system, is crucial for successful treatment and for avoiding complications during endodontic therapy; the aim was to find a correlation between a minimally invasive and less stressful endodontic access on Ni-Ti rotary instruments, but which allows correct vision and identification of anatomical reference points, simplifying the typologies based on the shape of the pulp chamber in coronal three-dimensional exam views. (2) Based on the inclusion criteria, 104 maxillary molars (52 maxillary first molars and 52 maxillary second molars) were included in the study after 26 Cone Beam Computed Tomography (CBCT) acquisitions (from 15 males and 11 females). And linear measurements were taken with the CBCT-dedicated software for subsequent analysis. (3) The results of the present study show data similar to those already published about this topic. Pawar and Singh's simplified classification actually seems to offer a schematic way of classification that includes almost all of the cases that have been analyzed. (4) The use of a diagnostic examination with a wide Field of View (FOV) and low radiation dose represents an exam capable of obtaining a lot of clinical information for endodontic treatment. Nevertheless, the endodontic anatomy of the upper second molar represents a major challenge for the clinician due to its complexity both in canal shape and in ramification.

18.
Diagnostics (Basel) ; 12(5)2022 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-35626197

RESUMEN

In recent years, CBCT has proved to be extremely widely used and widespread in dentistry [...].

19.
Diagnostics (Basel) ; 12(2)2022 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-35204626

RESUMEN

In recent years, improvements in imaging techniques have profoundly facilitated the diagnosis of pathologies of the maxillofacial district [...].

20.
Sci Prog ; 105(2): 368504221103763, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35656775

RESUMEN

The aim of this study was to explain the mechanical differences between EdgeTaper Platinum (ETP) and ProTaper Gold (PTG) determining the transition temperatures and the composition of the alloy of ETP, since no data are present in literature. A total of 130 instruments were selected: 65 ETP F2 and 65 PTG F2. 20 instruments per type were submitted to each mechanical tests. The cyclic fatigue and torsional tests were performed at a pre-set temperature of 35 °C ± 1 °C. During the cyclic fatigue test, Time to fracture, number of cycles to fracture (NCF) and the fragment length (FL) were recorded. During the static torsional, Torque to Fracture (TtF) and FL were recorded. The fracture surface of 5 randomly selected fragments from each test was examined through a Scanning Electron Microscopy (SEM) and an EDX analysis was performed. 20 instruments per type were submitted to a bending test The force generated (grams) to bend each was recorded. Recorded data of mechanical and metallurgical tests were statistically analyzed using a one-way analysis of variance (ANOVA) test with significance set to a 95% confidence level. ETP F2 showed a higher cyclic fatigue resistance and bending ability than PTG F2, with a statistically significant difference (p < 0.05). PTG showed a higher torsional resistance with a statistically significant difference (p < 0.05). DSC analysis of 5 samples for each instrument type pointed out that the austenite finish temperature of PTG was higher than the ETP, respectively of 49.99 ± 3.31 (°C) and 38.92 ± 1.75 (°C). EDX analysis confirmed the near-equiatomic composition of the Ni-Ti alloys, with a presence of a third component recognized as rubidium in the ETP samples. ETP showed higher flexibility in comparison with PTG, despite the latter is characterized by a more martensitic characterization. since its Af temperature is higher than the ETP.


Asunto(s)
Endodoncia , Calor , Metalurgia , Aleaciones , Endodoncia/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA