Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Echocardiography ; 39(6): 783-793, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35536700

RESUMEN

OBJECTIVES: To determine the 4D Flow Cardiac Magnetic Resonance (CMR) thresholds that achieve the best agreement with transthoracic echocardiography (TTE) for grading mitral regurgitation (MR). METHODS: We conducted a single-center prospective study of patients evaluated for chronic primary MR in 2016-2020. MR was evaluated blindly by TTE and 4D Flow CMR, respectively by two cardiologists and two radiologists with decades of experience. MR was graded with both methods as mild, moderate, or severe. 4D Flow CMR measurements included MR regurgitant volume per beat (RV) and mitral anterograde flow per beat (MF). RF was obtained as the ratio RV/MF. Additionally, MF was compared to left ventricular stroke volume (LVSV) by cine-CMR. RESULTS: We included 33 patients in the initial cohort and 33 in the validation cohort. Inter-observer agreement was excellent for 4D Flow CMR ICC = .94 (95% CI, .86-.97, p < 0.0001). Using recommended TTE thresholds (30 ml, 60 ml, 30%, 50%), agreement was moderate for RV and RF. The best agreement between 4D Flow CMR and TTE was obtained with CMR thresholds of 20 and 40 ml for RV (κ = .93; 95% CI, .8-1) and 20% and 37% for RF (κ = .90; 95% CI, .7-.9). In the validation cohort, agreement between TTE and 4D Flow CMR was good with the optimal thresholds (κ = .78; 95% CI, .61-.94). CONCLUSION: We propose CMR thresholds that provide a good agreement between TTE and CMR for grading MR. Further studies are needed to fully validate 4D-Flow CMR accuracy for primary MR quantification.


Asunto(s)
Insuficiencia de la Válvula Mitral , Ecocardiografía/métodos , Humanos , Imagen por Resonancia Cinemagnética/métodos , Espectroscopía de Resonancia Magnética , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Estudios Prospectivos , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad
3.
Heart Int ; 18(1): 38-43, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39006467

RESUMEN

Severe tricuspid regurgitation (TR) is a common pathology in the daily practice of a cardiologist. This disease entity is associated with significant morbidity and mortality if left untreated. Classically, surgical repair or replacement were the only therapeutic options present and were often not performed due to high postprocedural mortality. Transcatheter tricuspid valve intervention has emerged as a novel and effective therapeutic option for the treatment of significant TR. Several devices have been developed with different mechanisms of action. In this review, we will provide an overview of transcatheter edge-to-edge repair of TR using the TriClip device (Abbott, Santa Clara, CA, USA).

4.
Arch Cardiovasc Dis ; 2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-39089896

RESUMEN

BACKGROUND: Heart failure is associated with reduced quality of life, hospitalizations, death and high healthcare costs. Despite care improvements, the rehospitalization rate after an acute heart failure episode, especially for acute heart failure, remains high. METHODS: The Education Strategy for patients with acute Heart Failure (EduStra-HF; ClinicalTrials.gov Identifier NCT03035123) study will randomize patients admitted for acute heart failure in six French hospitals to usual care (control) or therapeutic education (intervention). All patients will be evaluated at baseline and will meet with a therapeutic education nurse before discharge. Those in the usual care arm will have standard appointments with their cardiologist and general practitioner. Those in the intervention arm will have an intensive follow-up schedule of phone calls, home visits and text messages from the therapeutic education nurses, plus cardiologist visits. Patients will be stratified by discharge location (home or cardiac rehabilitation centre) before randomization, and will be followed up for 1 year. The primary outcome will be the readmission rates for acute heart failure during 1 year in the two groups. Secondary outcomes will include: quality of life; time from inclusion to first readmission for acute heart failure; non-heart failure cardiovascular rehospitalization rates; length of stay for heart failure; cardiovascular and all-cause death; rates of patients receiving optimal medical therapies; evolution of knowledge about heart failure; and cost-effectiveness. CONCLUSIONS: This study will assess the efficacy and feasibility of a standardized management strategy for the care and follow-up of patients discharged after hospitalization for acute heart failure. The EduStra-HF strategy will combine various nurse care methods to help prevent rehospitalization.

5.
Arch Cardiovasc Dis ; 116(8-9): 366-372, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37573160

RESUMEN

BACKGROUND: Cardiac magnetic resonance imaging may provide a non-invasive alternative to coronary angiography for differentiating between ischaemic and non-ischaemic cardiomyopathy in cases of unexplained reduced left ventricular ejection fraction. AIM: The CAMAREC study aims to evaluate the diagnostic accuracy of cardiac magnetic resonance imaging in predicting significant coronary artery disease in patients with reduced left ventricular ejection fraction, using coronary angiography as the gold standard for comparison. METHODS: CAMAREC is a prospective cohort study of 406 patients in 10 centres with newly diagnosed, unexplained left ventricular ejection fraction ≤ 45%. Cardiac magnetic resonance imaging and coronary angiography will be conducted within a 2-week interval, starting with cardiac magnetic resonance imaging; independent committees will review the results blindly. Primary outcome is sensitivity of detecting ischaemic scar on cardiac magnetic resonance imaging for predicting significant coronary artery disease on coronary angiography according to Felker's criteria. Secondary outcomes include specificity and positive and negative predictive values (with 95% confidence intervals) of cardiac magnetic resonance imaging for predicting significant coronary artery disease in patients with reduced left ventricular ejection fraction, kappa concordance coefficient between cardiac magnetic resonance imaging and coronary angiography for diagnosing the affected myocardial territory, and the impact of cardiac magnetic resonance imaging on revascularization decisions. Two ancillary studies will evaluate the incremental cost-effectiveness of using cardiac magnetic resonance imaging first versus coronary angiography first, and the sensitivity of pre- and postcontrast T1-mapping for predicting significant coronary artery disease in patients with reduced left ventricular ejection fraction. CONCLUSION: Our study protocol is designed to rigorously evaluate cardiac magnetic resonance imaging as a non-invasive alternative to coronary angiography in patients with unexplained reduced left ventricular ejection fraction. The results will have significant implications for patient management, and may support growing evidence for the clinical utility of cardiac magnetic resonance imaging.


Asunto(s)
Enfermedad de la Arteria Coronaria , Disfunción Ventricular Izquierda , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico , Volumen Sistólico , Estudios Prospectivos , Función Ventricular Izquierda , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/etiología , Imagen por Resonancia Magnética
6.
JACC Case Rep ; 4(15): 962-966, 2022 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-35935153

RESUMEN

A 77-year-old patient with previous left atrial appendage (LAA) closure suffered from transient ischemic attack 6 years after the initial procedure. Computed tomography (CT) revealed appendage patency related to a late-acquired semicircular peri-device leak. The leak was treated by percutaneous LAA coiling. Subsequent clinical evolution was uneventful. (Level of Difficulty: Advanced.).

7.
Front Cardiovasc Med ; 9: 1036400, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36523367

RESUMEN

Objectives: This study aimed to describe the heterogeneous extension of mitral annular disjunction (MAD) and assess the hypotesis that different phenotypes of disjunction are not associated with increased surgical challenges. Background: Mitral regurgitation (MR) is the most common end-stage scenario of degenerative mitral valve disease (DMVD). Few data exist on the three-dimensional extension and geometry of MAD, as well as for its role in valvular dynamic and coaptation. Methods: A total of 85 consecutive subjects, who underwent elective mitral valve repair (MVR) for MMVD at our Institution between November 2019 and October 2021, were studied retrospectively. The extension and geometry of MAD was assessed using the digitally stored volumetric datasets of real-time 3D transesophageal echocardiography (TEE). Annular phenotypes and surgical repair techniques were analyzed. Results: Mitral annular disjunction was diagnosed in 50 out of 85 patients (59%) with Barlow disease (BD). A detailed analysis of MAD extension was conducted on 33 patients. Two pattern of disjunction were identified: a bimodal shape was highlighted in 21 patients, while a more uniform distribution of the disjuncted annulus was observed in 12 patients. The bimodal pattern was characterized by lower disjunction distance (DD) at the 140°-220° arch (3.6 ± 2.2 mm), while a more regular DD was measured in the remaining patients. All patients successfully underwent MVR. Triangular leaflet resection was performed in 58% of the cases, neochordae implantation in 9%, and notably a 27% received an isolated annuloplasty. Conclusion: Rather than a binary feature, MAD should be taken into account in its complex and heterogeneous morphology, where two major phenotypes can be identified. Despite its anatomical complexity, MAD was not associated with an increased surgical challenge; conversely a peculiar subgroup of patient was successfully treated with an isolated annuloplasty.

8.
JACC Case Rep ; 2(1): 145-149, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34316983

RESUMEN

A pregnant woman presented with symptomatic bioprosthetic mitral valve stenosis. We discuss the difficulties of decision making in this particular situation where two lives are at stake, the fetus's and the mother's, questioning whether transcatheter mitral valve-in-valve implantation can be an effective and safe option for this challenging condition. (Level of Difficulty: Advanced.).

10.
Eur J Cardiothorac Surg ; 50(2): 350-60, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27440158

RESUMEN

OBJECTIVES: An untreated dilated aortic annulus is a major risk factor for failure of aortic valve-sparing operations or repair of either bicuspid or tricuspid valve. Aortic annuloplasty efficiently reduces the annulus and increases the coaptation height, thus protecting the repair. This study analyses long-term results of 232 consecutive patients operated on with a standardized and physiological approach to aortic valve repair according to each phenotype of the dystrophic ascending aorta. Subvalvular aortic annuloplasty was systematically added using an external aortic ring to reduce annulus diameter when ≥25 mm. METHODS: Data were collected into the multicentric international AVIATOR registry (AorticValve repair InternATiOnal Registry): 149 patients with root aneurysm underwent remodelling with an external ring; 21 patients with tubular aortic aneurysm underwent supracoronary grafts with an external open ring and 62 patients with isolated aortic insufficiency (AI) underwent double sub- and/or supravalvular external open ring annuloplasty. Preoperative AI ≥ Grade III was present in 58.6% (133), and the valve was bicuspid in 37.9% (88). RESULTS: Cusp repair was performed in 75.4% (175) patients. The 30-day operative mortality rate was 1.4% (3). The mean follow-up was 40.1 ± 37.8 months (0-145.5). The actuarial survival rate at 7 years was 89.9%. The rate of freedom from reoperation at 7 years was similar among each phenotype, being 90.5% for root aneurysms, 100% for tubular aortic aneurysms and 97.5% for isolated AI with no difference between the bicuspid and tricuspid valve. The rates of freedom from AI ≥ Grade 2 and from AI ≥ Grade 3 at 7 years were, respectively, 76.0 and 93.1% for root aneurysms, 92.9 and 100% for tubular aortic aneurysms and 57.3 and 82.2% for isolated AI. Eye balling repair achieved suboptimal valve competency when compared with systematic cusp effective height assessment, which tended to improve the rate freedom from reoperation, respectively, from 85.8 ± 5.5% to 98.9 ± 1.1% and the rate of freedom from AI ≥ Grade 3 from 89.8 ± 4.9% to 100%. For isolated AI, an additional sinotubular junction ring (double sub- and supravalvular annuloplasty) tended to reduce recurrent AI when compared with single subvalvular annuloplasty. CONCLUSIONS: External aortic ring annuloplasty provides a reproducible technique for aortic valve repair with satisfactory long-term results for each ascending aorta phenotype with bicuspid or tricuspid valve. Longer follow-up is ongoing with the AVIATOR registry.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Anuloplastia de la Válvula Cardíaca/métodos , Prótesis Valvulares Cardíacas , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/mortalidad , Ecocardiografía Transesofágica , Femenino , Estudios de Seguimiento , Francia/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tasa de Supervivencia/tendencias , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
12.
Ann Thorac Surg ; 98(4): e101-2, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25282243

RESUMEN

We describe the replacement of a single cusp in two patients with severe aortic regurgitation due to endocarditis with a one third stentless bioprosthesis, with excellent results in both.


Asunto(s)
Válvula Aórtica/cirugía , Bioprótesis , Endocarditis/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anciano , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA