Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Sensors (Basel) ; 20(5)2020 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-32121462

RESUMEN

In the present study, we assessed for the first time the performance of our custom-designed low-cost Particulate Matter (PM) monitoring devices (Atmos) in measuring PM10 concentrations. We examined the ambient PM10 levels during an intense measurement campaign at two sites in the Delhi National Capital Region (NCR), India. In this study, we validated the un-calibrated Atmos for measuring ambient PM10 concentrations at highly polluted monitoring sites. PM10 concentration from Atmos, containing laser scattering-based Plantower PM sensor, was comparable with that measured from research-grade scanning mobility particle sizers (SMPS) in combination with optical particle sizers (OPS) and aerodynamic particle sizers (APS). The un-calibrated sensors often provided accurate PM10 measurements, particularly in capturing real-time hourly concentrations variations. Quantile-Quantile plots (QQ-plots) for data collected during the selected deployment period showed positively skewed PM10 datasets. Strong Spearman's rank-order correlations (rs = 0.64-0.83) between the studied instruments indicated the utility of low-cost Plantower PM sensors in measuring PM10 in the real-world context. Additionally, the heat map for weekly datasets demonstrated high R2 values, establishing the efficacy of PM sensor in PM10 measurement in highly polluted environmental conditions.

2.
J Conserv Dent ; 21(3): 328-332, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29899639

RESUMEN

AIM: The aim of this in vitro study was to evaluate and compare the microleakage of mineral trioxide aggregate (MTA) and Geristore root-end filling materials in different environments. MATERIALS AND METHODS: After removing the anatomical crowns of ninety extracted human maxillary central incisors, their root canals were instrumented and obturated. The apical 3 mm of each root was resected, and a standardized root-end cavity was prepared using an ultrasonic tip. The roots were alienated into three equal subgroups for each material and the root-end filling was performed in different environments namely dry, saliva contaminated, and blood contaminated. Samples were immersed in 0.2% Rhodamine B dye for 48 h. Roots were sectioned longitudinally and examined under a fluorescent microscope to measure the linear dye penetration. The results were statistically analyzed using analysis of variance and Tukey's honestly significant difference post hoc test. RESULTS: The Geristore dry group illustrated the lowest linear leakage, while the MTA saliva-contaminated group illustrated the highest leakage. In dry environment, linear dye penetration of both MTA and Geristore groups did not show any significant difference. However, statistically significant difference was observed between MTA and Geristore groups in blood- and saliva-contaminated environments. CONCLUSION: Geristore showed better results in saliva- and blood-contaminated environments; hence, Geristore may be used as an alternative to MTA for root-end filling.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA