Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 91(5): E29-E42, 2018 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-23436313

RESUMEN

Transcatheter aortic valve replacement (TAVR) with balloon-expandable Edwards-SAPIEN valve was superior to standard therapy in inoperable patients and noninferior to surgical aortic valve replacement in high surgical-risk, but operable patients, with severe symptomatic aortic stenosis in the randomized controlled PARTNER trial. Since the first case of TAVR with a balloon-expandable valve in 2002, several groups have reported their experience with balloon-expandable valves with high-procedural success. In the United States, the balloon-expandable Edwards-SAPIEN valve is the only transcatheter heart valve approved by the FDA for commercial use. Moreover, this is only in high-risk inoperable patients. Despite increasing experience with the TAVR procedure, it can be associated with complications, which can be technically challenging, even for an experienced operator. Complications associated with TAVR include vascular complications, valve malpositioning, regurgitation, embolization, coronary compromise, conduction abnormalities, stroke/transient ischemic attack, acute kidney injury, cardiac tamponade, and hemodynamic collapse. A thorough understanding of the procedure is essential for pre-emptive planning for procedural complications and early identification and management of complications are necessary for procedural success. We hereby review our experience of transfemoral TAVR with balloon-expandable valves, offer practical tips to maximize the likelihood of procedural success, describe pre-emptive strategies to prevent peri-procedural complications and bailout measures to manage them, should they occur. © 2018 Wiley Periodicals, Inc.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Valvuloplastia con Balón/efectos adversos , Cateterismo Periférico/efectos adversos , Arteria Femoral , Prótesis Valvulares Cardíacas , Complicaciones Posoperatorias/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Toma de Decisiones Clínicas , Arteria Femoral/diagnóstico por imagen , Humanos , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Punciones , Factores de Riesgo , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
2.
Catheter Cardiovasc Interv ; 85(1): 130-7, 2015 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-24677617

RESUMEN

OBJECTIVES: We sought to investigate the magnitude and clinical importance of thrombocytopenia post transcatheter aortic valve replacement (TAVR). BACKGROUND: Thrombocytopenia has been observed after TAVR but has not been well studied. METHODS: Major thrombocytopenia (platelet count <100 × 10(9) /L) was studied following aortic valve interventions in a single center. Changes in platelets were compared in 246 patients undergoing balloon-expandable TAVR and a similar population of 57 cases undergoing surgical aortic valve replacement (SAVR in the US PARTNER IA trial). RESULTS: An early drop in platelets was seen on the day of intervention. The drop day 1 post procedure was similar but slightly greater with SAVR vs. TAVR. In both platelet counts continued to drop, reaching a nadir of approximately 50-60% of the baseline platelet count at day 2-3, starting to recover after day 5. Early major thrombocytopenia occurred post TAVR in 37% of patients but was not significantly related to major bleeding (OR 0.89, 95% CI 0.51-1.60, P = 0.69) or risk of stroke (HR 0.61, 95% CI 0.16-2.20, P = 0.45); there was a trend to greater acute kidney injury (OR 1.76, 95% CI 0.95-3.26, P = 0.073) and mortality (HR 1.47, 95% CI 0.98-2.22, P = 0.065). Major thrombocytopenia was persistent in 7.7% of patients and this was independently associated with mortality (HR 3.65, 95% CI 1.63-8.16, P = 0.002). CONCLUSIONS: Post-TAVR thrombocytopenia is a common phenomenon and its magnitude appears similar to that seen after SAVR. It is most often transient, not associated with adverse sequelae and, unless persistent, should be managed in an expectant fashion. © 2014 Wiley Periodicals, Inc.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Trombocitopenia/etiología , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/mortalidad , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Estimación de Kaplan-Meier , Masculino , Oportunidad Relativa , Recuento de Plaquetas , Valor Predictivo de las Pruebas , Modelos de Riesgos Proporcionales , Diseño de Prótesis , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Trombocitopenia/sangre , Trombocitopenia/diagnóstico , Trombocitopenia/mortalidad , Trombocitopenia/terapia , Factores de Tiempo , Resultado del Tratamiento
3.
Catheter Cardiovasc Interv ; 84(2): 293-300, 2014 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-23873857

RESUMEN

OBJECTIVES: This study sought to investigate the immediate safety and feasibility of complete percutaneous access/closure of arteriotomy for device deployment compared to the surgical approach for transfemoral transcatheter aortic valve replacement (TAVR). BACKGROUND: The percutaneous approach for arterial access for device deployment in transfemoral TAVR is a potential alternative to the surgical approach. METHODS: In 274 patients who underwent transfemoral TAVR using Edward Sapien heart valve, 140 had a complete percutaneous approach using a "pre-closure" technique whereas 134 had surgical cut-down/repair for arterial access/closure of device deployment. Immediate vascular access/closure success, associated complications and clinical outcomes were compared. RESULTS: While overall acute success of access/closure and in-hospital access-related events were similar, significant isolated stenosis/dissection at the access site developed more frequently in the percutaneous group (7.1% vs. 0.7%, P = 0.007). Contrary, wound infections requiring prolonged antibiotics use or surgical debridement occurred more frequently in the surgical group (0.7% vs. 6.7%, P = 0.007). Although the rate of major vascular complications was not different, the surgical group developed more frequent minor bleeding (27.1% vs. 38.8%, P = 0.04) and underwent transfusion of packed red blood cells of ≤3 units (25.7% vs. 43.3%, P = 0.002). Median hospital stay was shorter in the percutaneous group (3 days vs. 4 days, P = 0.002). CONCLUSIONS: The percutaneous approach is a feasible access/closure method with a potential of lowering access site infection and bleeding, and shortening hospital stay, while maintaining similar rates of major vascular complications compared to the surgical approach.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Cateterismo Cardíaco/métodos , Arteria Femoral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Técnicas Hemostáticas , Anciano , Anciano de 80 o más Años , Antibacterianos/uso terapéutico , Estenosis de la Válvula Aórtica/diagnóstico , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Desbridamiento , Transfusión de Eritrocitos , Estudios de Factibilidad , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Hemorragia/etiología , Hemorragia/terapia , Humanos , Tiempo de Internación , Masculino , Diseño de Prótesis , Punciones , Reoperación , Estudios Retrospectivos , Infección de la Herida Quirúrgica/etiología , Infección de la Herida Quirúrgica/terapia , Factores de Tiempo , Resultado del Tratamiento
4.
Catheter Cardiovasc Interv ; 79(6): 903-9, 2012 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-21805570

RESUMEN

OBJECTIVE: Our aim was to compare the long-term outcomes between drug-eluting stents and bare-metal stents for saphenous vein graft stenosis. BACKGROUND: The ideal type of stent to treat saphenous vein graft stenosis has not been clearly established. Short-term randomized controlled trial results comparing drug-eluting stents with bare-metal stents for saphenous vein graft stenosis are conflicting, intermediate-term retrospective studies and meta-analyses at two years suggest no difference in outcomes, and there are no long term follow-up studies. The need for long term follow-up data has become emerged with concern over late stent thrombosis. METHODS: 246 saphenous vein graft patients undergoing stenting from August 2002-December 2008 were studied. Overall survival and event-free survival were compared by Kaplan-Meier method. Hazard ratios (HR) were calculated by Cox-proportional hazards models. RESULTS: We treated 133 patients with DES (median follow-up four years) and 113 patients with BMS (median follow-up four years) for SVG stenosis. Overall survival (77.0% ± 3.9% vs. 70.6% ± 4.6%, log-rank P = 0.60) and MACE-free survival (57.5% ± 4.6% vs. 56.8% ± 4.9, log-rank P = 0.70) were not significantly different between the DES and BMS groups. Although BMS was associated with increased risk of target lesion revascularization (TLR) (freedom from TLR 85.2% ± 3.5% vs. 90.0% ± 3.0%, HR 2.07, 95% CI 0.97-4.42, log-rank P = 0.05), there was no significant difference in the freedom from myocardial infarction (86.7% ± 3.3% vs. 88.7% ± 3.2%, log-rank P = 0.39) or target vessel revascularization (77.1% ± 4.2% vs. 76.1% ± 4.2%, log-rank P = 0.33) between the two groups. CONCLUSIONS: Although mortality is not statistically different between DES and BMS for SVG stenosis, BMS is associated with increased risk of revascularization, thus suggesting the superiority of DES over BMS in the long term.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Puente de Arteria Coronaria/efectos adversos , Stents Liberadores de Fármacos , Oclusión de Injerto Vascular/terapia , Metales , Vena Safena/trasplante , Stents , Anciano , Anciano de 80 o más Años , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Constricción Patológica , Angiografía Coronaria , Puente de Arteria Coronaria/mortalidad , Supervivencia sin Enfermedad , Femenino , Oclusión de Injerto Vascular/diagnóstico por imagen , Oclusión de Injerto Vascular/etiología , Oclusión de Injerto Vascular/mortalidad , Humanos , Estimación de Kaplan-Meier , Los Angeles , Masculino , Valor Predictivo de las Pruebas , Modelos de Riesgos Proporcionales , Diseño de Prótesis , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Vena Safena/diagnóstico por imagen , Factores de Tiempo , Resultado del Tratamiento
5.
Nephrol Dial Transplant ; 24(12): 3626-31, 2009 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19666662

RESUMEN

BACKGROUND: End-stage renal disease (ESRD) is commonly associated with anorexia, malnutrition and inflammation. In addition to serving as the primary reservoir for energy storage, adipocytes produce numerous pro- and anti-inflammatory mediators and regulate food intake by releasing the appetite-suppressing (leptin) and appetite-stimulating (adiponectin) hormones. Under normal conditions, release of leptin is stimulated by feeding to prevent excess intake, and release of adiponectin is stimulated by fasting to induce feeding. However, under certain pathological conditions such as inflammation, maladaptive release of these hormones leads to anorexia, wasting and malnutrition and simultaneously intensifies inflammation. Anorexia, malnutrition and inflammation in ESRD are frequently accompanied by hyper-leptinaemia. This study was designed to test the hypothesis that uraemic plasma may stimulate leptin release and suppress adiponectin release in normal adipocytes. METHODS: Visceral adipose tissue was harvested from normal rats, and adipocytes were isolated and incubated for 2-4 h in media containing 90% plasma from 12 ESRD patients (before and after haemodialysis) and 12 normal control subjects. RESULTS: The ESRD group had a marked elevation of plasma TNF-alpha, IL-6, IL-8 and leptin concentrations before and after haemodialysis. Incubation in media containing plasma from the ESRD group elicited a much greater leptin release by adipocytes than that containing normal plasma. Post-dialysis plasma evoked an equally intense leptin release. The rise in leptin release was coupled with a parallel fall in TNF-alpha concentration in the incubation media. In contrast to leptin, adiponectin release in the presence of uraemic plasma was similar to that found with the control plasma. CONCLUSIONS: Exposure to uraemic plasma induces exuberant release of leptin that is coupled with avid uptake of TNF-alpha by visceral adipocytes. These observations confirm the role of TNF-alpha, formerly known as cachexin, in the over-production and release of leptin in patients with ESRD.


Asunto(s)
Adipocitos/metabolismo , Leptina/metabolismo , Plasma/fisiología , Factor de Necrosis Tumoral alfa/metabolismo , Adulto , Animales , Células Cultivadas , Femenino , Humanos , Fallo Renal Crónico/metabolismo , Masculino , Ratas , Ratas Sprague-Dawley , Uremia
6.
Prog Cardiovasc Dis ; 59(4): 349-359, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-27956197

RESUMEN

Acute pericarditis is an acute inflammatory disease of the pericardium, which may occur in many different disease states (both infectious and non-infectious). Usually the diagnosis is based on symptoms (chest pain, shortness of breath), electrocardiographic changes (ST elevation), physical examination (pericardial friction rub) and elevation of cardiac biomarkers. It may occur in isolation or be associated with an underlying inflammatory disorder. In routine clinical practice, acute pericarditis can be associated with myocarditis due to their overlapping etiologies.


Asunto(s)
Pericarditis , Pericardio/diagnóstico por imagen , Enfermedad Aguda , Diagnóstico Diferencial , Electrocardiografía/métodos , Humanos , Pericarditis/diagnóstico , Pericarditis/etiología , Pericarditis/fisiopatología , Pronóstico
7.
EuroIntervention ; 11(4): 456-64, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25499834

RESUMEN

AIMS: Paravalvular aortic regurgitation (PVAR) after balloon-expandable transcatheter aortic valve implantation (TAVI) remains difficult to quantify, and the utility of the AR index (ARi) to create a composite aortic insufficiency (CAI) score was an important advance. Heart rate (HR) influences the ARi but the clinical relevance of this phenomenon remains poorly appreciated. We sought to validate a new composite heart-rate-adjusted haemodynamic-echocardiographic aortic insufficiency (CHAI) score in the prognostic evaluation of PVAR after balloon-expandable TAVI. METHODS AND RESULTS: The severity of PVAR was assessed immediately post TAVI by transoesophageal echocardiography (TOE) with simultaneous assessment of transcatheter haemodynamics. A total of 303 patients were studied. The CHAI score, incorporating the HR-adjusted diastolic-delta (HRA-DD, the difference between left ventricular and aortic diastolic pressures/HR*80), had a greater discriminatory value for one-year mortality than both PVAR by TOE (p=0.0018) and the previously proposed CAI score, based on the ARi without HR adjustment (p=0.0029). The CHAI score also better stratified percentage increases in left ventricular systolic chamber dimensions at one month and serum natriuretic peptide levels at one to three months. CONCLUSIONS: Prognostication of PVAR in the intermediate range of echocardiographic severity remains unreliable and is greatly enhanced by the integration of heart-rate-adjusted transcatheter haemodynamics.


Asunto(s)
Insuficiencia de la Válvula Aórtica/diagnóstico , Válvula Aórtica/fisiopatología , Presión Arterial , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Frecuencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/fisiopatología , Valvuloplastia con Balón , Cateterismo Cardíaco/mortalidad , Ecocardiografía Doppler en Color , Ecocardiografía Transesofágica , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Estimación de Kaplan-Meier , Masculino , Análisis Multivariante , Oportunidad Relativa , Valor Predictivo de las Pruebas , Modelos de Riesgos Proporcionales , Reproducibilidad de los Resultados , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Función Ventricular Izquierda , Presión Ventricular
8.
Eur Heart J Cardiovasc Imaging ; 15(12): 1324-32, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25187618

RESUMEN

AIMS: We sought to optimize a method for quantification of the calcium in the aortic-valvar complex for the prediction of significant paravalvular leak (PVL) after transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: All patients had severe symptomatic aortic stenosis and were treated with balloon-expandable TAVI (Sapien/Sapien-XT, Edwards Lifesciences LLC, Irvine, CA, USA). In order to correct for precise annular sizing, only patients with available contrast computed tomography (CT) data for measurements were included (n = 198). Paravalvular leak was quantified using peri-procedural transoesophageal echocardiography by Valve Academic Research Consortium-2 (VARC-2) criteria (grade ≥ moderate was considered significant). A detailed region-of-interest methodology separated quantification of calcium in each of the aortic leaflets to that in the left ventricular outflow tract (LVOT) and was used to predict PVL in receiver operator characteristic curve analyses. For non-contrast scans, the greatest discriminatory value for PVL was seen at the 450 Hounsfield Unit (HU) threshold for detection (volume ≥626 mm(3)), whereas for contrast scans it was at 850 HU (≥235 mm(3)). Left ventricular outflow tract calcium predicted PVL but only as a binary variable with no incremental value of quantification. In a multivariable binary logistic regression model, annulus area ≥ prosthesis area (OR 3.5, 95% CI 1.5-8.2, P = 0.005), contrast leaflet calcium volume (850-HU threshold) ≥235 mm(3) (OR 2.8, 95% CI 1.2-6.7, P = 0.023), and presence of LVOT calcium (OR 2.8, 95% CI 1.2-7.0, P = 0.022) were independent predictors for PVL ≥ moderate. CONCLUSION: Both leaflet and LVOT calcium are significant predictors of PVL and exert an important synergistic influence on this complication, even in appropriately sized valves. With careful attention to thresholds for detection, clinically relevant leaflet calcium volumes can be identified with either non-contrast or contrast CT scans.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/química , Calcinosis/diagnóstico , Calcio/análisis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Calcinosis/diagnóstico por imagen , Medios de Contraste , Ecocardiografía Transesofágica , Electrocardiografía , Femenino , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Masculino , Valor Predictivo de las Pruebas , Diseño de Prótesis , Falla de Prótesis , Reproducibilidad de los Resultados , Factores de Riesgo , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Factores de Tiempo , Tomografía Computarizada por Rayos X/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
9.
J Am Coll Cardiol ; 61(9): 908-16, 2013 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-23449425

RESUMEN

OBJECTIVES: This study compared cross-sectional three-dimensional (3D) transesophageal echocardiography (TEE) to two-dimensional (2D) TEE as methods for predicting aortic regurgitation after transcatheter aortic valve replacement (TAVR). BACKGROUND: Data have shown that TAVR sizing using cross-sectional contrast computed tomography (CT) parameters is superior to 2D-TEE for the prediction of paravalvular aortic regurgitation (AR). Three-dimensional TEE can offer cross-sectional assessment of the aortic annulus but its role for TAVR sizing has been poorly elucidated. METHODS: All patients had severe symptomatic aortic stenosis and were treated with balloon-expandable TAVR in a single center. Patients studied had both 2D-TEE and 3D imaging (contrast CT and/or 3D-TEE) of the aortic annulus at baseline. Receiver-operating characteristic curves were generated for each measurement parameter using post-TAVR paravalvular AR moderate or greater as the state variable. RESULTS: For the 256 patients studied, paravalvular AR moderate or greater occurred in 26 of 256 (10.2%) of patients. Prospectively recorded 2D-TEE measurements had a low discriminatory value (area under the curve = 0.52, 95% confidence interval: 0.40 to 0.63, p = 0.75). Average cross-sectional diameter by CT offered a high degree of discrimination (area under the curve = 0.82, 95% confidence interval: 0.73 to 0.90, p < 0.0001) and mean cross-sectional diameter by 3D-TEE was of intermediate value (area under the curve = 0.68, 95% confidence interval: 0.54 to 0.81, p = 0.036). CONCLUSIONS: Cross-sectional 3D echocardiographic sizing of the aortic annulus dimension offers discrimination of post-TAVR paravalvular AR that is significantly superior to that of 2D-TEE. Cross-sectional data should be sought from 3D-TEE if good CT data are unavailable for TAVR sizing.


Asunto(s)
Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Ecocardiografía , Prótesis Valvulares Cardíacas , Humanos , Curva ROC , Tomografía Computarizada por Rayos X
10.
J Am Coll Cardiol ; 59(14): 1275-86, 2012 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-22365424

RESUMEN

OBJECTIVES: In an effort to define the gold standard for annular sizing for transcatheter aortic valve replacement (TAVR), we sought to critically analyze and compare the predictive value of multiple measures of the aortic annulus for post-TAVR paravalvular (PV) regurgitation and then assess the impact of a novel cross-sectional computed tomographic (CT) approach to annular sizing. BACKGROUND: Recent studies have shown clear discrepancies between conventional 2-dimensional (2D) echocardiographic and CT measurements. In terms of aortic annular measurement for TAVR, such findings have lacked the outcome analysis required to inform clinical practice. METHODS: The discriminatory value of multiple CT annular measures for post-TAVR PV aortic regurgitation was compared with 2D echocardiographic measures. TAVR outcomes with device selection according to aortic annular sizing using a traditional 2D transesophageal echocardiography-guided or a novel CT-guided approach were also studied. RESULTS: In receiver-operating characteristic models, cross-sectional CT parameters had the highest discriminatory value for post-TAVR PV regurgitation: This was with the area under the curve for [maximal cross-sectional diameter minus prosthesis size] of 0.82 (95% confidence interval: 0.69 to 0.94; p < 0.001) and that for [circumference-derived cross-sectional diameter minus prosthesis size] of 0.81 (95% confidence interval: 0.7 to 0.94; p < 0.001). In contrast, traditional echocardiographic measures were nondiscriminatory in relation to post-TAVR PV aortic regurgitation. The prospective application of a CT-guided annular sizing approach resulted in less PV aortic regurgitation of grade worse than mild after TAVR (7.5% vs. 21.9%; p = 0.045). CONCLUSIONS: Our data lend strong support to 3-dimensional cross-sectional measures, using CT as the new gold standard for aortic annular evaluation for TAVR with the Edwards SAPIEN device.


Asunto(s)
Insuficiencia de la Válvula Aórtica/prevención & control , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Anciano de 80 o más Años , Distribución de Chi-Cuadrado , Ecocardiografía Transesofágica/métodos , Femenino , Estudios de Seguimiento , Prótesis Valvulares Cardíacas , Humanos , Masculino , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Complicaciones Posoperatorias/prevención & control , Valor Predictivo de las Pruebas , Cuidados Preoperatorios/métodos , Estudios Prospectivos , Diseño de Prótesis , Curva ROC , Medición de Riesgo , Estadísticas no Paramétricas , Resultado del Tratamiento
11.
Cardiol Clin ; 29(2): 211-22, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21459244

RESUMEN

Over the past two decades, echocardiography has replaced cardiac catheterization for aortic valvular hemodynamic assessment. In recent years, however, there has been a rapid evolution of transcatheter aortic valve technology and, with its refinement, there has been the increasing recognition of the value of transcatheter hemodynamic assessment in complementing the information provided by contemporary echocardiography. With an emphasis on transcatheter hemodynamics, this article reviews the symbiotic application of these assessment modalities pertaining to contemporary transcatheter aortic valve implantation.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas/normas , Válvula Aórtica/patología , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/patología , Estenosis de la Válvula Aórtica/fisiopatología , Bioprótesis/normas , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/normas , Ecocardiografía Doppler , Análisis de Falla de Equipo , Implantación de Prótesis de Válvulas Cardíacas/normas , Hemodinámica , Humanos , Atención Perioperativa , Diseño de Prótesis , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
12.
Am J Cardiol ; 107(3): 360-6, 2011 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-21256999

RESUMEN

The American College of Cardiology/American Heart Association recently updated recommendations for percutaneous coronary intervention (PCI) of unprotected left main coronary artery (ULMCA) disease from class III to II(b) according to the results of the SYNergy between percutaneous coronary intervention with TAXus and cardiac surgery (SYNTAX) trial. The SYNTAX score is an angiographic tool using solely the coronary anatomy. We studied the effect of co-morbidities (Parsonnet's score) on the ability of the SYNTAX score to predict long-term outcomes in patients with ULMCA disease treated by revascularization. A total of 328 patients underwent revascularization of ULMCA from April 2003 to February 2007. Of the 328 patients, 120 underwent PCI (median follow-up 973 days) and 208 underwent coronary artery bypass grafting (CABG) (median follow-up 1,298 days). The ability of the SYNTAX score to predict outcomes was assessed using the Cox proportional hazards model. The outcomes between the PCI and CABG groups were compared by propensity analysis. The median SYNTAX score was 26 in the PCI and 28 in the CABG group (p = 0.5). In the PCI group, greater quartiles were associated with worse survival (62.1% at SYNTAX score of ≥36 vs 82.4% at SYNTAX score of <36, p = 0.03) and all-cause mortality, myocardial infarction, cerebrovascular events, and target vessel revascularization-free (MACCE) survival (47.7%, SYNTAX score ≥20 vs 76.6%, SYNTAX score <20, p = 0.02). Using the Parsonnet score as a covariate, the SYNTAX score continued to be an independent predictor of MACCE and demonstrated a trend toward predicting mortality in the PCI group. In contrast, the SYNTAX score did not predict the outcomes for the CABG group. No difference was found in mortality between the PCI and CABG groups for ULMCA disease, regardless of coronary complexity; although greater SYNTAX scores were associated with increased MACCE rates with PCI compared to CABG. Both the coronary anatomy (SYNTAX score) and co-morbidities (Parsonnet's score) predicted long-term outcomes for PCI of ULMCA disease. In contrast, the SYNTAX score did not predict the outcomes after CABG. In conclusion, the ideal scoring system to guide an appropriate revascularization decision for ULMCA disease should take into account both the coronary anatomy and the co-morbidities.


Asunto(s)
Angioplastia Coronaria con Balón , Angiografía Coronaria , Enfermedad Coronaria/terapia , Anciano , Comorbilidad , Puente de Arteria Coronaria , Enfermedad Coronaria/mortalidad , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Puntaje de Propensión , Modelos de Riesgos Proporcionales , Resultado del Tratamiento
13.
Am J Cardiol ; 106(8): 1075-80, 2010 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-20920641

RESUMEN

A meta-analysis of published studies was conducted to evaluate the incidence, predictors, and clinical outcomes of stent fractures. Eight studies with 108 stent fractures in 5,321 patients were analyzed using the Bayesian method. Study end points included in-stent restenosis (ISR) and target lesion revascularization (TLR). The mean incidence of stent fracture per patient was 4.0% (95% confidence interval 0.4% to 16.3%). All cases, except 1, were reported with sirolimus-eluting stents. The incidence of stent fracture was 30.4% in the left anterior descending coronary artery, 10.9% in the left circumflex coronary artery, 56.4% in the right coronary artery, < 0.01% in the left main coronary artery, and 1.7% in saphenous vein grafts. The probability of stent fracture was significantly higher in the right coronary artery than in the left anterior descending and left circumflex lesions (p < 0.01). Left main stents were less likely to fracture compared to those in all other vessels (p < 0.01). The probability of stent fracture was significantly increased in overlapping stents (7.5% vs 2.1%, p = 0.01) and long stents (46 vs 32.5 mm, p < 0.01). Lesions with stent fractures had higher rates of ISR (38% vs 8.2%, p < 0.01) and TLR (17% vs 5.6%, p < 0.01). Conversely, the probability of stent fractures was higher in patients with ISR (12.8% vs 2.1%, p < 0.01) and TLR (8.8% vs 2.7%, p < 0.01). In conclusion, although not always associated with clinical sequelae, the probability of ISR and TLR is increased with stent fracture. Conversely, the probability of stent fractures is increased in lesions with ISR or TLR, thus raising the need for surveillance and management guidelines for at-risk patients.


Asunto(s)
Reestenosis Coronaria/epidemiología , Reestenosis Coronaria/etiología , Isquemia Miocárdica/cirugía , Stents , Humanos , Incidencia , Falla de Prótesis , Factores de Riesgo , Estados Unidos/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA